CATALOG FOR PRESSURE CONTROL EQUIPMENT Supplement 1 API TOP CONNECTORS TRADEMARK WOODCO BUY THE BRAND REG. U.S. PATENT OFFICE MANUFACTURER
|
|
- Rafe Parsons
- 6 years ago
- Views:
Transcription
1 ATALOG FOR PRESSURE ONTROL EQUIPMENT Supplement 1 API TOP ONNETORS This catalog supplement provides detailed information about API Top onnectors manufactured by. You will find the equipment listed by Flange or (lamp) Hub size and pressure, with parts illustrated and a table of part numbers. TRADEMARK WOODO USA BUY THE BRAND REG. U.S. PATENT OFFIE MANUFATURER P.O. Box 1261 Houston, Texas U.S. and anada: Fax: contact@woodcousa.com Effective Date: Feb 1, 2005 presents this catalog to gain your attention and secure your business
2 atalog for Pressure ontrol Equipment, Sup. 1 Page 2 TABLE OF ONTENTS Section 1.0 General Purpose Application Specification Reference Standards Material Service Temperature Design Quality Supplemental Requirements Section 2.0 Equipment Flange and Hub Top onnector Features Flange Top onnector Parts, Table Hub Top onnector Parts, Table Section 3.0 Assembly Assembly Details and Instructions Figure 1, Top onnector Figure 2, Flange Top onnector Detail Figure 3, Hub Top onnector Detail Figure 4, Top onnector Shown W/ Tommy Bars Figure 5, Top onnector Disassembled Figure 6, Top onnector Plug (Bonnet, ap) Figure 7, Flange Top onnector Assembled
3 atalog for Pressure ontrol Equipment, Sup. 1 Page General offers supplements to general catalogs in order to provide more detailed information about specific equipment. 1.1 Purpose intends this supplement to communicate the design, material, and advantages of Top onnectors as specified in the informative Annex K, of API Spec 6A, 20th Edition. 1.2 Application Top onnectors using the uppermost collar connection shown in API Spec 6A allow operators and service companies to use interchangeable equipment when making service equipment attachment to the top of well head hristmas Trees. 1.3 Specification Top onnectors meet all the defined requirements of API Spec 6A. 1.4 Reference Standards API Spec 6A API Spec 16A Note: API Spec 6A, 20th Edition provides Informative information about Top onnectors with a paragraph in Annex K, K.4 warning that specified Top onnector bores will not pass a drift or Backpressure Valve. Top onnectors will pass both Drifts and Backpressure Valves and satisfy all API specified design requirements. See Section 1.7 of this catalog. 1.4 Reference Standards API Spec 6A API Spec 16A 1.5 Material Top onnectors meet API Spec 6A material requirements including the special Annex K requirement that all Top onnector material meet 75 K strength regardless of working pressure. Annex K specifies that Top onnectors utilize only the following material classes. DD-Sour Service a EE-Sour Service a FF-Sour Service a HH-Sour Service a a b c d Flange / Body, ollar & Plug. arbon or low alloy steel b arbon or low alloy steel b Stainless steel b RA bcd As defined by NAE Standard MR0175/ISO In compliance with NAE Standard MR-01-75/ISO RA required on retained fluid wetted surfaces only; RA cladding of low allow or stainless steel permitted. RA as defined in API 6A latest edition. NAE MRO175/ISO definition of RA does not apply.
4 atalog for Pressure ontrol Equipment, Sup. 1 Page Service Temperature API Spec 6A Annex K makes no mention of service temperature yet specifies the use of FKM (Viton) elastomer seal material. This material has a normal temperature service range of -20 F to 400 F. The following API 6A temperature classifications fall within -20 F to 350 F. Temperature Operating Range lassification * ( Degrees Fahrenheit [ F] ) Min. Max. P -20 to 180 R Room Temperature S 0 to 140 T 0 to 180 U 0 to 250 V 35 to 250 X** 0 to 350 * PURHASER MAY OMBINE TEMPERATURE LASSES e.g. PX, -20 TO 350 F ** MAY REQUIRE DERATING Operators may specify lower temperature ratings K (-75 F to 180 F), L (-50 F to 180 F) and N (-50 F to 140 F) using elastomer seals other than FKM. 1.7 Design Top onnectors have lowermost connectors meeting API Spec 6A requirements for Flanges, and API Spec 16A requirements for (lamp) Hub connections. Body diameters between lower and upper connections have maximum allowed diameters. Plugs have spiral retainer rings to keep them connected with nuts and help extract the plug when operators need to enter the well through the hristmas Tree. All manufactured Top onnectors have API full bores allowing the normal installation of Back Pressure Valves through the hristmas Tree. 1.8 Quality defines Product Quality as conformance to specified requirements. We select suppliers on the basis of their ability to provide materials, products and/or services which conform to and API specifications. All individual units must pass inspections during and after production, and each unit receives a hydrostatic body test. Operators may specify API Spec 6A PSL levels. 1.9 Supplemental Requirements Buyers should clearly define, at the time of order, any requirements which exceed or differ from API Spec 6A.
5 2.0 Equipment atalog for Pressure ontrol Equipment, Sup. 1 Page Flange and Hub Top onnector Features OPTIONS LIFTING API 16A HUB Figure 1, Top onnector API 6A FLANGE Full compliance with the details and intent of API Spec 6A, Annex K, assures field interchangeability with service equipment having API designated collar connections. full bore designs allow Back Pressure Valve installation through the Top onnector. provides a gall resistant coating on all units regardless of material to reduce field corrosion and prevent galling on sensitive surfaces. The ollar (Nut) has a course knurled surface and Tommy Bar holes to facilitate installation and removal of the ollar. A spiral retainer ring on the Plug allows the collar to lift the plug when opening the collar connection. Bonnet may have configuration to provide a lug to accept a Lifting Shackle. { I.D. 10M AND LOWER PRESSURE 1/2 NPT 15M AND 20M PRESSURE F562 (AUTOLAVE) (AP/PLUG) RETAINER OLLAR (NUT) SEAL (OPTIONAL) INTERNAL LIFT THREAD SEAL WITH BAKUP, REQUIRED FOR SOME SIZES AND PRESSURES. SEE PARTS TABLES 1 AND 2.
6 FLANGE SIZE atalog for Pressure ontrol Equipment, Sup. 1 Page Flange Top onnector Parts Reference this page to order parts for Flange Top onnectors. Size and pressure along with part numbers designate equipment geometry only. Buyers must additionally specify: PSL, Material lass, Service Temperature and any special requirements. Table 1, Top onnectors and Top onnector Parts (AP/PLUG) OLLAR (NUT) INTERNAL LIFT THREAD (OPTIONAL) GASKET (AP PLUG) Figure 2, Flange Top onnector Detail I.D. { API 6A FLANGE 10M AND LOWER PRESSURE 1/2 NPT 15M AND 20M PRESSURE F562 (AUTOLAVE) OLLAR (NUT) RETAINER SEAL WITH BAKUP, REQUIRED FOR SOME SIZES AND PRESSURES. SEE TABLE BELOW. RETAINER TEST PORT PLUG SEAL LIFTING SHAKLE LIFTING (All dimensions in inches) BAKUP BAKUP O- 2-1/16 5M* R /16 10M* BX /16 15M* BX /16 20M* BX /16 5M R /16 10M BX /16 15M BX /16 20M BX /8 5M R /16 10M BX /16 15M BX /16 5M R /16 10M BX /16 15M BX /8 5M R /8 10M BX /8 15M BX /16 10M BX * NOT SHOWN IN API 6A
7 HUB SIZE atalog for Pressure ontrol Equipment, Sup. 1 Page Hub Top onnector Parts Reference this page to order parts for Hub Top onnectors. Size and pressure along with part numbers designate equipment geometry only. Buyers must additionally specify: PSL, Material lass, Service Temperature and any special requirements. Table 2, Top onnectors and Top onnector Parts (AP/PLUG) OLLAR (NUT) INTERNAL LIFT THREAD (OPTIONAL) GASKET (AP PLUG) Figure 3, Hub Top onnector Detail I.D. { API 16A HUB 10M AND LOWER PRESSURE 1/2 NPT 15M AND 20M PRESSURE F562 (AUTOLAVE) OLLAR (NUT) RETAINER SEAL WITH BAKUP, REQUIRED FOR SOME SIZES AND PRESSURES. SEE TABLE BELOW. RETAINER TEST PORT PLUG SEAL LIFTING SHAKLE LIFTING (All dimensions in inches) BAKUP BAKUP O- 2-1/16 5M* BX /16 10M* BX /16 15M* BX /16 20M* BX /16 5M BX /16 10M BX /16 15M BX /16 20M BX /8 5M BX /16 10M BX /16 15M BX /16 5M BX /16 10M BX /16 15M BX /8 10M BX /8 15M BX /16 10M BX * NOT SHOWN IN API 6A
8 3.0 Assembly atalog for Pressure ontrol Equipment, Sup. 1 Page Assembly Details and Instructions Figure 4, Top onnector W/ Tommy Bars The Top onnector follows the API Spec 6A Annex K specifications, dimensions, and design. has added the feature of Tommy Bar holes in the ollar to facilitate turning of the ollar to connect or disconnect the ollar connection. All made Top onnectors, have a gall resistant coating on all surfaces. During original assembly, applies water-resistant grease on the plug and collar. When operators remove the Plug and ollar, recommends the replacement of this lubricant. Seal rings and backup rings prove easier to install when lightly lubricated with water-resistant grease (applied by hand, brush application of lubricant may cause problems if the brush should lose a bristle that might end up behind or across a seal). INSTALL 2 FIELD AQUIRED TOMMY BARS (1/2 X HT BAR STOK, OR 1/2 X 12 B7 UNTHREADED BOLT STOK)TO FAILITATE LOOSENING OR TIGHTENING OLLAR (NUT)
9 atalog for Pressure ontrol Equipment, Sup. 1 Page Assembly Details and Instructions (ontinued) Figure 5, Top onnector Disassembled BLEEDER ONNETION SPIRAL RETAINER OLLAR (NUT) PLUG (, AP) SEAL(S) BODY } 10M AND LOWER PRESSURE 1/2 NPT 15M AND 20M PRESSURE F562 (AUTOLAVE) } LUBRIATE } TO PREVENT ORROSION, APPLY ABUNDANT GREASE, BY HAND (TOO MUH IS BEST. DO NOT USE A BRUSH, AS LOOSE HAIRS OR BRISTLES MAY PREVENT SEALING). (SEE FIGURE 6 FOR SEAL W / BAK-UP ) EXTERNAL THREAD OF BODY AND INTERNAL THREAD OF NUT WITH API RP 543 / ISO THREAD OMPOUND
10 atalog for Pressure ontrol Equipment, Sup. 1 Page Assembly Details and Instructions (ontinued) Figure 6, Top onnector Plug (Bonnet, ap) When replacing the seals of any Top onnector that require a Back-up Ring, always install the Back-up Ring above the Seal Ring. The smaller cross section o-ring acts to keep the Back-up Ring closed and in place in the groove. SEAL WITH BAKUP
11 atalog for Pressure ontrol Equipment, Sup. 1 Page Assembly Details and Instructions (ontinued) Figure 7, Flange Top onnector Assembled The completed assembly should appear as below. No force greater than hand tightening with 2-12 long Tommy Bars should prove necessary.
12 atalog for Pressure ontrol Equipment, Sup. 1 Page 12
13 Terms of Use Welcome to, the official website of ( WOODO ). www. woodcousa.com provides services to you subject to the following conditions. If you visit com, you accept these conditions. Please read them carefully. In addition, when you use any current or future woodcousa.com service or download software, you also agree to comply with any of these conditions that may apply to such service or software use. may change, add, or remove portions of its website at any time. also may impose limits on certain features and services or restrict access to all or any part of its website without notice or liability. intends its website (the ontent ) for your personal use only. All materials published on the website have copyright protection pursuant to U.S. and international copyright laws. You may not modify, publish, transmit, participate in the transfer or sale of, reproduce (except as provided in Paragraph 4 below), create new works from, distribute, perform, display, or in any way exploit any of the ontent in whole or in part. You shall abide by all additional copyright notices, information, and other restrictions associated with any of the ontent. You may download or copy the ontent and other downloadable items forming parts of the ontent for personal use only, provided that you maintain all copyright and other notices contained therein. You may not copy or store any ontent for other than personal use without prior written permission from an officer of. does not assume liability for any errors or omissions in the ontent, or in the transmission or delivery of all or any part thereof, or for any damages arising there from. You acknowledge sole responsibility (sole risk) for any reliance you may have in the ontent or actions you may take relying upon any of the ontent. makes every effort to assure the accuracy of the ontent, but, MAKES THE ONTENT AVAILABLE TO YOU ON AN AS IT APPEARS BASIS, WITHOUT WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, INLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF TITLE OR IMPLIED WARRANTIES OF MERHANTABILITY OR FITNESS FOR A PARTIULAR PURPOSE. YOU HEREBY AKNOWLEDGE THAT YOU USE THE ONTENT AT YOUR SOLE RISK. You shall have no rights to any of the proprietary rights associated with any of the ontent. may, in its sole discretion, terminate or suspend access to all or part of the ontent for any reason, including without limitation, breach or assignment of this Agreement. This Agreement originates in Houston, Texas and any interpretation and/or enforcement shall comply with Texas law. Any action to enforce this agreement shall occur in, and only in, the federal or state courts located in Harris ounty, Texas. Privacy - Please review our Privacy Policy, which also governs your visit to woodcousa.com, to understand our practices. Please direct all questions to: sitemaster@woodcousa.com opyright Notice ,. will enforce all rights under copyright law, regarding all photographs, graphics, written materials or other content appearing on this website, the legally protected property of WOODO USA. prohibits reproduction or re-use of any kind, other than that described in Terms of Use above, without written permission from an officer of. Submit all requests for re-use of copyrighted materials in writing to: sitemaster@woodcousa.com
WHEATLEY Series 500 Swing Check Valve
Document Number: TC003001-13 Revision: 02 WHEATLEY Series 500 Swing Check Valve Installation, Operation, and Maintenance Manual TABLE OF CONTENTS BILL OF MATERIALS...3 SCOPE...5 INSTALLATION AND OPERATION
More informationWHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual
WHEATLEY SERIES 500 SWING CHECK VALVE STANDARD INTEGRAL SEAT & OPTIONAL REMOVABLE SEAT 2" FP - 6" FP 150# - 1500# 8" FP - 12" FP 150# - 900# API 6D and B16.34 2" FP - 4" FP 5000# DRILLING PRODUCTION VALVE
More informationTHE PROCESS OF JOINT INTEGRITY
BOLTED JOINTS A.333 THE PROCESS OF JOINT INTEGRITY To assist in managing a process, ask yourself the following questions: why, what, who, and how? Why do we need a Flange Joint Integrity program? This
More informationVALVCHEQ BACKFLOW PREVENTERS FIGURE RP03
Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections FEATURES GENERAL APPLICATION The RP03 provides protection from both backsiphonage and backpressure
More informationConstant Pressure Crude Oil Container Model CPCCP
Installation, Operations, and Maintenance Manual Constant Pressure Crude Oil Container Model CPCCP The information in this manual has been carefully checked for accuracy and is intended to be used as a
More informationUn-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs
Un-Pressurized Orefice Fittings FIO EZ Parts List and Operation Instructions TECHNICAL MANUAL Dn 2-6 Class 150-600 Lbs US US 2 FIO EZ - MT 108-US - 05-2016 FIO EZ Important Instructions US Pietro Fiorentini
More informationWHEATLEY Series 822/820 Swing Check Valve
Document Number: TC003001-12 Revision: 02 WHEATLEY Series 822/820 Swing Check Valve Installation, Operation, and Maintenance Manual TABLE OF CONTENTS BILL OF MATERIALS...3 SCOPE...4 INSTALLATION AND OPERATION
More information5k Slickline Lightweight Pressure Control Equipment 4 ID
5k Slickline Lightweight Pressure Control Equipment 4 ID Table of Contents 5k Slickline Lightweight Pressure Control Equipment 4 ID... 1 Hydraulic Slickline Stuffing Box... 3 Wireline Lubricators... 4
More informationRECOMMENDATION FOR INTERCHANGEABLE FLANGED DRILLING CHOKE DIMENSIONS
RECOMMENDATION FOR INTERCHANGEABLE FLANGED DRILLING CHOKE DIMENSIONS TECHNICAL REPORT TR0601 AWHEM publications may be used by anyone desiring to do so. Every effort has been made by the Association to
More informationInstallation, operation & maintenance manual - original version
Installation, operation & maintenance manual - original version AVK gate valves for water and wastewater Series 01, 02, 06, 12, 15, 18, 20, 26, 32, 33, 36, 38, 50, 55 and 636 COPYRIGHT AVK GROUP A/S 2018
More informationMUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5
operating Instructions manual MUELLER Mega-Lite Drilling Machine table of contents PAGE Equipment 2 Operating Instructions 3-4 Parts Information 5 Travel Charts 6-11! WARNING: 1. Read and follow instructions
More informationSECTION BUTTERFLY VALVES
SECTION 15112 BUTTERFLY VALVES PART 1 GENERAL 1.01 SUMMARY A. All butterfly valves shall be of the tight closing, rubber seated type and fully comply with the latest revision of AWWA Standard C504, Class
More informationMUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.
Installation Instructions manual MUELLER table of contents PAGE A-20806 A-20807 Adjustable General Information 2 Technical Data 3 Dimensions 4 Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator
More information299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012
Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of
More informationMUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.
Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read
More information64 Series Pressure Reducing Regulators
Instruction Manual Form 1245 64 Series March 2006 64 Series Pressure Reducing Regulators W1943 Figure 1. 64 Series Regulator Introduction Scope of Manual This manual provides instructions for the installation,
More informationInstallation and Operation Manual
Installation and Operation Manual WIKA FLR-SBDF / BLR-SBDF Magnetic Level Transmitter (Please retain for future usage) Contact: Gayesco-WIKA USA, L.P. 229 Beltway Green Boulevard Pasadena, TX 77503 www.wika.com
More informationReduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections
VALVCHEQ Backflow Preventers Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections Features General application The RP03 provides protection from both
More informationPP-1, PP-1W, PP-2, & PP-3
Welker Pitot Probe Model PP-1, PP-1W, PP-2, & PP-3 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for the installation, operation, and maintenance
More informationIAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE
INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC 157-20067 1 PURPOSE 1.1 The purpose of this standard is to establish an acceptable standard
More informationMUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.
Installation Instructions manual MUELLER table of contents PAGE A-20808 General Information 2 Technical Data 3 Dimensions 4 A-20809 Non-Adjustable Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator
More informationTHE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301
THE HF-300 SERIES Operating and Service Manual Series includes all variants of HF-300/301 Issue A July 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 3.1. Spring Loaded...
More informationPressure Regulating Valves. Models 44, 77 & 68 PS\ UL. Pressure Relief Valve. Dorot Fire Protection Division. Certification & compliance by design
Fire Protection Div. Dorot Fire Protection Division Models, & 6 PS\ UL Pressure Relief Valve Certification & compliance by design -PS\UL ANSI FCI - Class VI seat leakage class Fire tested to EN ISO 6-:6
More informationOn-Off Connector Skirt
On-Off Connector Skirt Retrievable Packers & Accessories The On-Off Connector Skirt is compact, reliable, fully sealing, J-type tubing disconnect device that automatically engages and releases with a small
More informationInstallation Instructions
Installation Instructions Durametallic MD-200 Series Gas Dual Cartridge Canister Seal for Mixers and Agitators Experience In Motion 1 Equipment Check 1.1 Follow plant safety regulations prior to equipment
More informationLost Circulation Material Evaluation Receiver Instruction Manual
Lost Circulation Material Evaluation Receiver Instruction Manual Manual No. D00943152, Revision B Instrument No. 102308743 Fann Instrument Company, Inc. LCM Evaluation Receiver Instruction Manual 2016
More informationCLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.
Page 1 of 7 CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD 1. SCOPE 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems. 1.2 The piping system as used herein is
More informationISO INTERNATIONAL STANDARD. Earth-mover tyres and rims Part 3: Rims. Pneumatiques et jantes pour engins de terrassement Partie 3: Jantes
INTERNATIONAL STANDARD ISO 4250-3 Third edition 2006-08-01 Earth-mover tyres and rims Part 3: Rims Pneumatiques et jantes pour engins de terrassement Partie 3: Jantes Reference number ISO 2006 PDF disclaimer
More information61 Series Pilots for Pilot-Operated Pressure Reducing Regulators
61 Series Pilots for Pilot-Operated Pressure Reducing Regulators June 2011 Introduction 61 Series pilots are used with Types 1098-EGR and EZL pressure reducing regulators. These pilots can also be integrally
More informationINSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures
INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures MINT-0289-XX TABLE OF CONTENTS Limited Warranty... 3 User Responsibility... 3-4 General Service... 4 Safety Precautions.... 5 Physical Dimensions..
More informationAWWA C504 COMPLIANT VALVES FROM 3 THRU 108
AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 PO Box 411 Berwick PA 18603 800-247-VALV www.crispinvalve.com 500 SERIES: Sizes 3-20 Available The K-Flo 500 Series is a heavy-duty resilient seated butterfly
More informationDisassembling and assembling APP and APP 16-22
MAKING MODERN LIVING POSSIBLE Instruction Disassembling and assembling APP 11-13 and APP 16-22 ro-solutions.com Table of Contents 1. Disassembling...3 2. Disassembling the pump...3 3. Assembling the pump....7
More informationBS Series Basket Strainer
BS Series Basket Strainer Operating, Installation, & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems. Dated 04-26-12 PRESSURE DROP SIMTECH strainers are engineered to offer the lowest
More informationVALVCHEQ BACKFLOW PREVENTERS FIGURE RP03
Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections FEATURES GENERAL APPLICATION The RP03 provides protection from both backsiphonage and backpressure
More informationInstallation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Welker Probe Instrument Regulator Model The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for
More informationModel C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644
Technical Services: Tel: (00) 31-9312 / Fax: (00) 791-5500 Model C Pipe Line Strainer 6, & 10 Inch (150, & 250) 250 psi (17,2) General Description The welded steel body Model C Pipe Line Strainers (Ref.
More informationINSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL
WedgeRock RW Series Worm Gear Actuators INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL Revision 01 Date 4/3/17 Page 1 Table of Contents 1.0 INTRODUCTION... 4 1.1 PURPOSE... 4 1.2 AUDIENCE...
More informationHomestead Series 820 AWWA Butterfly Valves
Homestead Series 820 AWWA Butterfly Valves Dependable Valves for Water & Wastewater Service BODY: The ductile iron body meets or exceeds the design strength requirements of the AWWA C504 standards. Flange
More informationFloat Operated Level Controllers
CONTENTS Float Operated Level Controllers IM0015 Nov. 2014 PAGE Introduction 1 Scope 1 Description 1 Specification 1 Control Installation 2 INTRODUCTION Side Mount Back Mount Prior to installing, the instructions
More informationWKM Model 320F Floating Ball Valve
Date: 4 WKM Model 320F Floating Ball Valve Installation, Operation, and Maintenance Manual 1 Date: 4 All the information contained in this manual is the exclusive property of Cameron. Any reproduction
More informationAmerican Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM
American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1003 - REVISED: 2009 Water Pressure Reducing Valves for Domestic Water Distribution Systems MANUFACTURER: CONTACT
More informationSection GATE VALVES
Section 02521 PART 1 GENERAL 1.01 SUMMARY This Section includes the furnishing and installation of gate valves for isolation and dead-end service as shown on Plans and as specified herein. 1.02 MEASUREMENT
More informationCOSASCO 6000 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE
COSASCO 6000 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE 11841 Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 www.cosasco.com Page: 2 of 26 Revision
More informationATS430 turbidity sensor Retractable insertion assembly
A MEASUREMENT & ANALYTICS INSTRUCTION ATS430 turbidity sensor Retractable insertion assembly Measurement made easy 1 Introduction This publication details installation procedures for the retractable insertion
More information3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor
Membrane Contactors 3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor Assembly and Disassembly Instructions 3M.com/Liqui-Cel TABLE OF CONTENTS I. Safety Information 3 II. Required Materials 4
More information1305 Series Pressure Reducing Regulators
Instruction Manual Form 1095 1305 Series October 2009 1305 Series Pressure Reducing Regulators! Warning Fisher regulators must be installed, operated, and maintained in accordance with federal, state,
More informationPressure Dump Valve Service Kit for Series 2300 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit
More informationISO INTERNATIONAL STANDARD. Earth-mover tyres and rims Part 3: Rims. Pneumatiques et jantes pour engins de terrassement Partie 3: Jantes
INTERNATIONAL STANDARD ISO 4250-3 Third edition 2006-08-01 Earth-mover tyres and rims Part 3: Rims Pneumatiques et jantes pour engins de terrassement Partie 3: Jantes Reference number ISO 4250-3:2006(E)
More informationInstallation Instructions, Pressure Regulator Series
Installation Instructions, Pressure Regulator 20517 Series Manual Model: 20517, L20517 Air motor Operated: F20517, LF20517 Hydraulic Motor Operated: G20517, LG20517 1. GENERAL ------------------------------------------------------------------------------
More informationFLANGED MULTI-PORT BALL VALVES
INTRODUCTION This instruction manual includes installation, operation and maintenance information for flanged multi-port ball valves. This manual addresses lever operated ball valves only. Please refer
More informationType ACE97 Pad-Depad Valve
Instruction Manual Form 5665 Type ACE97 November 2011 Type ACE97 Pad-Depad Valve DEPAD PILOT VALVE DEPAD MAIN VALVE W8161 ACTUATOR VENT GAS INLET PAD VALVE TO TANK Figure 1. Type ACE97 Pad-Depad Valve
More informationModel NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters
Data Sheet DS/NDA-EN Rev. H Model NDA Differential pressure transmitter Deltapi N Series A complete range of pneumatic pressure transmitters Introduction The blind type differential pressure transmitter
More informationБерг АБ Тел. (495) , факс (495) Turning Ideas Into Engineered Solutions KAYDON RING & SEAL, INC.
Turning Ideas Into Engineered Solutions RING & SEAL, INC. K-CBS Series Circumferential Barrier Seals Kaydon s high performance circumferential barrier seals back up DGS systems with performance & economy.
More informationTeam Insert Valve Sample Specification The Insert Valve shall conform to the following:
Team Insert Valve Sample Specification The Insert Valve shall conform to the following: The Ductile Iron 250 p.s.i.g. Insert Valve shall be a Resilient Wedge Gate Valve designed for use in potable water,
More information3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors
Membrane Contactors 3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors Assembly and Disassembly Instructions 3M.com/Liqui-Cel TABLE OF CONTENTS I. Safety and Warning 3 II. Assembly Parts 4 III.
More informationFITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI
Jetstream offers a wide variety of fittings with various connection types to fit your 20,000 psi application needs. The standard connection types, Type M, MP, and MP Tube lance, are available in standard
More informationModel B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data
Technical Services: Tel: (800) 381-312 / Fax: (800) 71-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Model B-1 Pipe Line Strainer 3,, 6 & 8 Inch (DN80, DN100, DN150
More informationSLAM-SHUT VALVE. Type OSE CONTENTS INTRODUCTION CHARACTERISTICS. Scope of Manual. Material. Product Description. Connections
Instruction Manual D103687X012 June 2017 Type OSE SLAM-SHUT VALVE CONTENTS Introduction... 1 Characteristics... 1 Labelling... 2 Dimensions and Weights... 3 Operation... 4 Installation... 4 Commissioning...
More informationPressure Dump Valve Service Kit for Series 3000 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator
More informationFLANGED TWO-PIECE BALL VALVES
INTRODUCTION This instruction manual includes installation, operation, and maintenance information for FNW flanged split-body ball valves. This manual addresses lever operated ball valves only. Please
More informationInstallation Instructions
Installation Instructions TM Five Star Seal 80 Series Dual, Cartridge Mounted, Flexible Stator Pusher Seal Designed for General Service Applications 86 and 87 Experience In Motion Description The 86/87
More informationINSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES
PBV-USA,Inc. 12735 Dairy Ashford. Stafford, Texas USA 77477 281-340-5400; 800-256-6193 FAX: 281-340-5499 INDUSTRIAL BALL VALVES IM0 69 April 2001 Rev 9 INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS
More informationISO 1977 INTERNATIONAL STANDARD. Conveyor chains, attachments and sprockets. Chaînes de manutention, plaques-attaches et roues dentées
INTERNATIONAL STANDARD ISO 1977 Second edition 2006-08-15 Conveyor chains, attachments and sprockets Chaînes de manutention, plaques-attaches et roues dentées Reference number ISO 1977:2006(E) ISO 2006
More informationSizing, Selection, and Installation of Pressure-relieving Devices in Refineries
Sizing, Selection, and Installation of Pressure-relieving Devices in Refineries Part I Sizing and Selection Downstream Segment API STANDARD 520 EIGHTH EDITION, DECEMBER 2008 Special Notes API publications
More informationOperating Instructions
LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.
More informationSUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide
SUMMITTM 400 & 600 Natural Gas Barbecues Step-By-Step Guide W E B E R W E B E R W E B E R W E B E R Summit 400 NG Summit 600 NG CANADIAN GAS ASSOCIATION R A P P R O V E D WARNING: Follow all leak check
More informationOperating Procedures for GripTight 15.5 SDR & IPS Test Plugs
EST Group DC2518 08/01 REV 3 12/12 Page 1 of 6 Operating Procedures for GripTight SDR & IPS Test Plugs WARNING For proper operation, GripTight plugs must be assembled as shown in Figure 1. Pressure testing
More informationInstallation Instructions and valve Maintenance Rev. 0 of 21/09/15
ASSEMBLING PROCEDURE AND VALVE MAINTENANCE 1.0.... Safety Information 2.0.. INTRODUCTION 3.0 VARIATIONS 4.0..ASSEMBLING PROCEDURE FOR THE STEM 5.0 ASSEMBLING PROCEDURE FOR OUTLET CONNECTIONS 6.0 PROCEDURE
More informationInstallation Operation Maintenance
682 Seal Cooler New generation seal cooler to meet and exceed the seal cooler requirements stated in the 4th Edition of API Standard 682 Installation Operation Maintenance Experience In Motion Description
More informationInstallation, Operation & Maintenance Manual
Original Instructions Installation, Operation & Maintenance Manual Sentry VREL Control Valve Pressure Conditioning S-SW-IOM-00277-15 1-17 Table of Contents Safety Information... 3 General Safety Precautions...
More informationLIQUID LEVEL GAUGE FOR WELDING ZGAU 716 O&M, 717 O&M, 718 O&M, 719 O&M
LIQUID LEVEL GAUGE FOR WELDING ZGAU 7 O&M, 77 O&M, 78 O&M, 79 O&M Edition: 07/0 Date: 0.07.0 GO WITH OUR FLOW SPIS TREŚCI. Introduction. Construction. Installation. Installation of liquid level gauge of
More informationCoiling Tube with Twist-Proof Fitting
http://www.pisco.co.jp FITTING CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Anti-Twisting Coiling Tube for Air Tool Coiling Tube with Twist-Proof Fitting 306 Avoid Twisted Tube Problem
More information6PS SERIES HERMETIC STAINLESS STEEL PRESSURE SWITCH Introduction
6PS SERIES HERMETIC STAINLESS STEEL PRESSURE SWITCH Introduction KLIXON 6PS series stainless steel pressure switch is a snap-acting, all welded device hermetically sealed switch contacts. All switch components
More informationContinental Industries TRANSITION FITTINGS or FAX Visit
Continental Industries TRANSITION FITTINGS 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and
More information1805 Series Relief Valves
October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications
More informationFLANGED TWO-PIECE BALL VALVES
INTRODUCTION This instruction manual includes installation, operation, and maintenance information for FNW flanged split-body ball valves. This manual addresses lever operated ball valves only. Please
More informationMODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL
MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL Index 1. List of components / General arrangement 2. Description 3. Handling 4. Installation 5. Actuators / Operation 6. Maintenance a. Changing
More informationLARGE R/W GATE VALVES
The original, and the definitive standard. LARGE R/W GATE VALVES 24 THROUGH 54 STYLE 7000 AWWA C515 250 PSI NSF 61 Certified Fusion Bond Epoxy Coated 10 Year Limited Warranty M&H Valve is a division of
More informationIndex Table. Model 794. Installation, Operating and Maintenance Instructions
CLOCKWISE MANUAL MAKING INTO CCW TABLE Index Table Model 794 Installation, Operating and Maintenance Instructions Black & Webster Products Division 545 Hupp Ave. P.O. Box 831, Jackson, Michigan 49204 2009
More information1700ESL Kamvalok Coupler
PART #H32138PA November 2008 1700ESL Kamvalok Coupler OPW Transport Series Dry Disconnect Couplings are considered the standard of the industry. For use on multi-compartment petroleum, solvent and chemical
More informationInstallation Instructions For Flat Seated Bolted Type RAH Series Disk Holders
Installation Instructions For Flat Seated Bolted Type RAH Series Disk Holders RA Series Rupture Disks 1. WARNING a) Read the complete instructions before attempting to install the rupture disk and holder
More informationGILMONT ACCUCAL FLOWMETERS
OPERATING MANUAL GILMONT ACCUCAL FLOWMETERS 28W092 Commercial Ave. Barrington, IL U.S.A. 60010-2392 (847) 381-4888 (847) 381-7053 (Fax) 800-962-7142 www.barnant.com e-mail: barnant@barnant.com A-1299-0766
More informationSempell High Pressure Forged Check Valves Forged steel, swing check and tilting disc configuration
Installation and Maintenance Instructions Handling requirements A - Packed valves Pallets: Lifting and handling of the packed valves in pallets will be carried out by a fork lift truck, by means of the
More informationTHE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401
THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special
More informationAnderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions
Before installation these instructions must be fully read and understood Installation and maintenance instructions for Series 93 Positive Pressure Pilot Operated Safety Relief Valves (POSRV). The intent
More information453 Series Steam Heated Vaporizing Regulator
ADI 0453A Certified ISO 9001:2000 453 Series Steam Heated Vaporizing Regulator INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation
More informationAIR/OVER HYDRAULIC JACK 20 TON
AIR/OVER HYDRAULIC JACK 0 TON 4487 ASSEMBLY AND OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com Copyright 999 by Harbor Freight Tools.
More informationSEries 29 Hydrant valves installation, operation & maintenance manual
Instruction for use Thank you for selecting an AVK product. With correct use, it will give long and reliable service. This manual has been prepared to assist you install, operate and maintain the valve
More informationEnglish. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING
Contents All Products... Gb-1 Control Valves... Gb-2 Control Valve Actuators... Gb-3 Regulators... Gb-3 Relief Valves... Gb-4 Instruments, Switches, and Accessories... Gb-4 Products Covered by Battery
More informationInstallation, Operation and Maintenance Manual for Back Pressure Regulator
Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN
More informationLUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS
AIR FILTER, REGULATOR AND LUBRICATOR 4035 ASSEMBLY AND OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com Copyright 004 by Harbor Freight
More informationGAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS
GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS CONTINENTAL INDUSTRIES, INC. The Ultimate Connection CONTINENTAL INDUSTRIES, INC. ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, Inc.,
More informationSAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE
SAPAG IMPORTANT NOTICE Contents Important notice 1 0 Valve identification 2 1 Storage 2 2 Installation 2 3 Operation 2 4 Maintenance 3 4.1 Dismantling 3 4.2 Inspection 3 4.3 Repair 3 4.4 Assembly 4 4.5
More informationRepair instructions. Pivot bushing replacement. XL-AS10001RM-en-DE Rev B
Repair instructions Pivot bushing replacement XL-AS10001RM-en-DE Rev B Table of contents Table of contents 1 General information... 3 1.1 Safety information...3 1.2 Legal information...4 1.3 Order and
More informationHigh Pressure Equipment Taper Seal Valves, Fittings and Tubing
igh quipment Taper Seal Valves, ittings and Tubing 0,000 and,000 psi service igh quipment Company has developed the Taper Seal line of products to assure safe and easy plumbing through,000 psi. These needle
More informationISO INTERNATIONAL STANDARD. Fluid power systems O-rings Part 2: Housing dimensions for general applications
INTERNATIONAL STANDARD ISO 3601-2 First edition 2008-06-15 Fluid power systems O-rings Part 2: Housing dimensions for general applications Transmissions hydrauliques et pneumatiques Joints toriques Partie
More informationHot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS
262-2040 Hot Tapping Machine For performing 1/4 6 Hot taps 285 psi or less. Municipal Water, Sewage, & Building Services Use OPERATIONS MANUAL and OPERATING INSTRUCTIONS WARNING: These instructions are
More informationType BBS-03, BBS-05, BBS-06, BBS-25
Type BBS-03, BBS-05, BBS-06, BBS-25 Sterile connection elements Sterile Verbindungselemente Raccords union stériles Operating Instructions Bedienungsanleitung Manuel d utilisation 1. THE OPERATING INSTRUCTIONS
More informationCOSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE
COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE Rohrback Cosasco Systems, Inc. 11841 E. Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 www.cosasco.com
More informationprecision pipe fittings
Precision Pipe Fittings 1 8 to 1 sizes 316 stainless steel, brass, and exotic materials NPT threads HOKE PO Box 4866 Spartanburg, SC 29305-4866 Phone (864) 574-7966 Fax (864) 587-5608 www.hoke.com Sales-hoke@circor.com
More information