Advance Optima -- High Performance Measurement Technology Oxygen Analyzer Module Magnos 16/17

Size: px
Start display at page:

Download "Advance Optima -- High Performance Measurement Technology Oxygen Analyzer Module Magnos 16/17"

Transcription

1 Advance Optima -- High Performance Measurement Technology Oxygen Analyzer Module Magnos 16/17 Part of the Advance Optima product family, with all advantages Magnos 16 Magnetomechanical measuring principle Short T 90 time Freely selectable measuring ranges Highly suppressed measuring ranges High accuracy and stability Monitoring of the measuring chamber flow rate Calibration without bottled test gas TÜV approval Magnos 17 Thermomagnetical measuring principle Robust measuring cell The Advance Optima features one housing, a single system controller module, one user interface and multiple analyzer modules. All these analyzer modules have the same mechanical and electrical interfaces and plug directly into the standard housing. Other than the analyzer modules, all components are standard throughout the system. Oxygen Analyzer Modules Magnos 16 and Magnos 17 The measuring principles for the Magnos 16 and 17 are based on the specific paramagnetic behaviour of oxygen. These analyzers are characterized by a high measurement accuracy and stability. In order to cover a broad scope of applications, ABB Analytical offers the Magnos with two different measuring techniques.

2 TELEDYNE ANALYTICAL INSTRUMENTS Model 3010M P a r a m a g n e t i c O x y g e n A n a l y z e r Advanced paramagnetic sensor with barometric pressure compensation and PID temperature control for enhanced stability Exceptional performance and price value Proven Teledyne microprocessor-based platform Designed for common air separation unit, medical air, and medical oxygen applications Teledyne's Model 3010MA Paramagnetic Percent Oxygen Analyzer is a versatile, microprocessor-based instrument specifically designed for oxygen purity analysis. The 3010MA is a precise, cost effective instrument capable of measuring percent oxygen in specific ranges as required by the air separation and medical gas qualification industries. Drawing on the solid performance of Teledyne's highly successful 3000 series control platform, the 3010MA provides the user with a wide variety of features while maintaining cost effectiveness. PRINCIPLE OF MEASUREMENT The physical property distinguishing oxygen from other gases is its paramagnetism that is significantly greater than that of other common gases. Consequently, the molecules of oxygen are attracted by strong magnetic fields -- a phenomena which can be used for detection purposes. A paramagnetic sensor consists of two spheres arranged in the form of a dumbbell suspended in a symmetrical, non-uniform magnetic field. When the surrounding gas contains oxygen, the dumbbell spheres rotate out of the magnetic field by the relatively strong attraction of oxygen. A light beam focused on a mirror attached to the dumbbell reflects asymmetrically onto two photo diodes resulting in a voltage shift. The voltage difference produces a current used to drive the dumbbells back to the original position. The current flow required to maintain the null position is directly proportional to the oxygen concentration and is shown linearly in volume percent oxygen in the display. Properly maintained paramagnetic sensors last for years with little or no upkeep. STABILITY BUILT-IN Paramagnetic sensors, operating under suppressed, highpurity conditions, are natively subject to swings in their output based on changes in the surrounding barometric pressure. To properly compensate for such atmospheric pressure changes, Teledyne has incorporated an absolute pressure sensor in our system design. In addition, to ensure an enhanced, stable performance, Teledyne maintains the paramagnetic sensor in its own isolated, heated compartment. A PID controller is used to properly control and maintain the temperature within the sensor compartment to optimize the analysis. The analysis section is mounted directly beside the 3010MA control unit allowing for a panel-saving, single 19" rack mount configuration. FLEXIBILITY The 3010MA offers three dynamic, user-configurable ranges plus auto-ranging. The instrument is linear on all three ranges, eliminating the need to recalibrate while switching between ranges. The analyzer comes standard with an isolated 4-20 madc output for oxygen concentration and range identification (optional). Additionally, a bi-directional RS-232C serial communication interface provides for remote monitoring and control of span and zero functions. Teledyne provides auto-calibration capabilities as a standard feature in the 3000 series platform.

3 MODEL 3010MA PARAMAGNETIC OXYGEN ANALYZER APPLICATIONS Air separation Bulk gas plants Medical air / medical oxygen qualifications ADVANTAGES Linearity of analysis across three user-selectable ranges Temperature controlled / isolated sensor for long term stability Atmospheric Pressure Compensation for high-end, accurate performance Auto-ranging to follow process upsets Auto-calibration electronics standard Exceptional value at a favorable price STANDARD FEATURES Proven, robust paramagnetic sensor Three user-selectable ranges plus cal range Signal output: isolated 4-20mADC Programmable auto-ranging Two fully adjustable concentration alarm set points with programmable relay functions, Form C contacts, 3A resistive Calibration contact span / zero, Form A normally open contacts, 3A resistive Self diagnostics with Form C failure alarm contacts Full duplex RS-232C communication link Five digit oxygen concentration LED display 2 x 20 alphanumeric vacuum fluorescent display for set up and diagnostics Switch selectable power supply: or VAC at 47 / 63 Hz Remote calibration digital inputs Specifications Ranges: 3 user selectable ranges of %, % and %; auto-ranging with ID output Accuracy: ± 0.045% O2 absolute at constant temperature (once thermal equilibrium has been achieved) ± 0.05% O2 over the entire operating temperature range (once thermal equilibrium has been achieved) Response time: 90% of full scale in < 10 seconds at 77 F (25 C) Linearity: Zero drift: Span drift: Repeatability: 0.1% oxygen ±0.5% oxygen per month ±0.5% oxygen per month ±0.10% oxygen Operating temp: 68 to 86 F (20 to 30 C) Outputs: Alarms: Analysis display: Menu display: Digital interface: Two 0-1 VDC and two 4-20 madc isolated (concentration and range ID) 1 x system-failure alarm contact to detect power failure; 2 x adjustable concentration threshold alarms with fully programmable set-points. 5 digit red LED, 3/5" high numerals 20 character, 2 line vacuum fluorescent Full duplex RS-232C communications port Power requirements: or VAC at 47 / 63 Hz (user selected on rear of control unit) Oxygen sensor: Long-life paramagnetic detector Sample connections: User specified 1/4" or 6 mm fittings Area classification: General purpose, indoor environment Mounting: 19" rack mount Dimensions: 8.7" H x 19" W x 12.23" L Weight: 35 lbs (16 Kg) TELEDYNE ANALYTICAL INSTRUMENTS A Teledyne Technologies Company Chestnut Street City of Industry, California 91748, USA Warranty Instrument is warranted for 1 year against defects in material or workmanship NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice. TEL: or FAX: ask_tai@teledyne.com Teledyne Analytical Instruments, A Teledyne Technologies Company. All rights reserved. Printed in the USA. 11/05LD

4

5

6

7

8 Teledyne Analytical Instruments 3000MB Paramagnetic Oxygen Analyzer Microprocessor based Exceptional performance, price value Advanced paramagnetic sensor Designed for the air separation industry Teledyne s Model 3000MB Paramagnetic Percent Oxygen Analyzer is a versatile, microprocessor based instrument specifically designed to detect oxygen in a variety of gases. The 3000MB is a precise, cost effective instrument capable of measuring percent oxygen in as low as the 0-1% range. Drawing on the solid performance of Teledyne s highly successful 3000 series control platform, the 3000MB provides the user with a wide variety of features and options to satisfy virtually any application. PRINCIPLE OF MEASUREMENT The physical property distinguishing oxygen from other gases is its paramagnetism which is significantly greater than that of common gases. Consequently the molecules of oxygen are attracted by strong magnetic fields which can be used in detection. A paramagnetic sensor consists of two spheres arranged in the form of a dumbbell suspended in a symmetrical, non-uniform magnetic field. When the surrounding gas contains oxygen, the dumbbell spheres rotate out of the magnetic field by the relatively strong attraction of oxygen. A light beam focused on a mirror attached to the dumbbell reflects asymmetrically onto two photo diodes resulting in a voltage shift. The voltage difference produces a current used to drive the dumbbells back to the original position. The current flow required to maintain the null position is directly proportional to the oxygen concentration and is shown linearly in volume percent oxygen in the display. Properly maintained paramagnetic sensors last for years with little or no attention making them ideal for critical measurements in the low percent range. FLEXIBILITY The 3000MB offers three dynamic, user-configurable ranges plus autoranging, and can be calibrated in any range. The instrument is linear on all three ranges, eliminating the need to recalibrate while switching between ranges. The analyzer comes standard with an isolated 4-20 madc output for oxygen concentration and range identification. Additionally, a bi-directional RS- 232C serial communication interface provides for remote monitoring and control of span and zero functions. Teledyne provides auto-calibration capabilities as a standard feature in the 3000 series platform. APPLICATIONS Monitoring inert gas blanketing Air separation and liquefaction Chemical reaction monitoring Emissions monitoring Petrochemical process control Quality assurance Gas analysis certification THE LEADER IN OXYGEN The 3000MB can be ordered as a standard unit or as part of a larger analytical system. With over 50 years of analytical instrument experience, Teledyne supplies sensors, custom engineered analyzers and complete monitoring systems to satisfy unique applications. From portables to on-line units, in microprocessor based or analog configurations, no other manufacturer comes close to matching Teledyne s breadth of instrumentation. ADVANTAGES Linearity of analysis across three user-selectable ranges Autoranging to follow process upsets Auto-calibration electronics standard

9 MODEL 3000MB PARAMAGNETIC Oxygen Analyzer STANDARD FEATURES Proven, robust paramagnetic sensor Three user-selectable ranges plus cal range Signal and Range ID output: isolated 4-20 madc Programmable autoranging Two fully adjustable concentration alarm set points with programmable relay functions, Form C contacts, 3A resistive Calibration contact span/zero, Form A normally open contact, 3A resistive Self diagnostics with Form C failure alarm contacts Full duplex RS-232C communication link Five digit oxygen concentration LED display 2x20 alphanumeric vacuum fluorescent display for set up and diagnostics Brass sample passages and fittings Universal power supply: VAC / Hz Remote calibration digital inputs OPTIONS -C Electronically operated cal/zero valves SPECIFICATIONS Ranges: 3 user selectable ranges; typical ranges 0-5% to 0-100%; autoranging with ID output (lower ranges available) Calibration range: 0-25% Accuracy: ± 1% of full scale at constant temperature ± 5% of full scale over operating temperature range on factory default analysis ranges, once thermal equilibrium has been achieved Response time: 90% of full scale in < 10 seconds at 77 F (25 C) Linearity: 0.1% O2 Zero drift: 0.05% O2 / 1 month Span drift: 1% FS / 1 month Repeatability: 0.1% / FS Operating temp: Outputs: 32 to 113 F (0 to 45 C) Two 0-1 VDC & two 4-20 madc isolated (concentration and range ID) Alarms: One system-failure alarm contact to detect power failure; two adjustable concentration threshold alarms with fully programmable setpoints Analysis display: 5 digit red LED, 3/5 high numerals Menu display: 20 character, 2 line vacuum fluorescent Digital interface: Full duplex RS-232C communications port Power requirements: Universal AC input ranges, 100 to 240 VAC, 50 / 60 Hz, 70 watts max Oxygen sensor: Paramagnetic Sample connections: User specified 1/4 or 6mm fittings Area classification: Dimensions: General purpose, non-hazardous Optional: FM approved for Class 1, Div 2 (no purge ) Y purged for Class 1 Div 1 areas W x H x 8.9 D Model 3000MB Sample Gas Conditioning Requirements Sample inlet pressure: Sample flow: Sample dewpoint: Sample temperature: 0 to 50 C Detector wetted parts: 5 to 20 psig (regulate to fixed inlet pressure) 1 to 2 SCFH Non-condensing at ambient temperature Glass, steel, gold, viton, acrylic glass, epoxy resin For complete turnkey systems, please contact Teledyne or your local representative TELEDYNE ANALYTICAL INSTRUMENTS A Teledyne Technologies Company Chestnut Street City of Industry, California 91748, USA Warranty Instrument is warranted for 1 year against defects in material or workmanship NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice. TEL: or FAX: ask_tai@teledyne.com Teledyne Analytical Instruments, A Teledyne Technologies Company. All rights reserved. Printed in the USA. 10/05LD

10 Teledyne Analytical Instruments 3000MA Paramagnetic Oxygen Analyzer Microprocessor based Exceptional performance, price value Advanced paramagnetic sensor Designed for air separation industry Teledyne s Model 3000MA Paramagnetic Percent Oxygen Analyzer is a versatile, microprocessor based instrument specifically designed to detect oxygen in a variety of gases. The 3000MA is a precise, cost effective instrument capable of measuring percent oxygen in as low as the 0-1% range. Drawing on the solid performance of Teledyne s highly successful 3000 series control platform, the 3000MA provides the user with a wide variety of features and options to satisfy virtually any application. PRINCIPLE OF MEASUREMENT The physical property distinguishing oxygen from other gases is its paramagnetism which is significantly greater than that of common gases. Consequently the molecules of oxygen are attracted by strong magnetic fields which can be used in detection. A paramagnetic sensor consists of two spheres arranged in the form of a dumbbell suspended in a symmetrical, non-uniform magnetic field. When the surrounding gas contains oxygen, the dumbbell spheres rotate out of the magnetic field by the relatively strong attraction of oxygen. A light beam focused on a mirror attached to the dumbbell reflects asymmetrically onto two photo diodes resulting in a voltage shift. The voltage difference produces a current used to drive the dumbbells back to the original position. The current flow required to maintain the null position is directly proportional to the oxygen concentration and is shown linearly in volume percent oxygen in the display. Properly maintained paramagnetic sensors last for years with little or no attention making them ideal for critical measurements in the low percent range. FLEXIBILITY The 3000MA offers three dynamic, user configurable ranges plus autoranging, and can be calibrated in any range. The instrument is linear on all three ranges, eliminating the need to recalibrate while switching between ranges. The analyzer comes standard with an isolated 4-20 madc output for oxygen concentration and range identification. Additionally, a bi-directional RS-232C serial communication interface provides for remote monitoring and control of span and zero functions. Teledyne provides autocalibration capabilities as a standard feature in the 3000 series platform. APPLICATIONS Monitoring inert gas blanketing Air separation and liquefaction Chemical reaction monitoring Emissions monitoring Petrochemical process control Quality assurance Gas analysis certification THE LEADER IN OXYGEN The 3000MA can be ordered as a standard unit or as part of a larger analytical system. With over 50 years of analytical instrument experience, Teledyne supplies sensors, custom engineered analyzers and complete monitoring systems to satisfy unique applications. From portables to on-line units, in microprocessor based or analog configurations, no other manufacturer comes close to matching Teledyne s breadth of instrumentation. ADVANTAGES Linearity of analysis across three user-selectable ranges Autoranging to follow process upsets Auto-calibration electronics standard

11 MODEL 3000MA PARAMAGNETIC Oxygen Analyzer STANDARD FEATURES Proven, robust paramagnetic sensor Three user-selectable ranges plus cal range Signal and Range ID output: isolated 4-20 madc Programmable autoranging Two fully adjustable concentration alarm set points with programmable relay functions, Form C contacts, 3A resistive Calibration contact span/zero, Form A normally open contact, 3A resistive Self diagnostics with Form C failure alarm contacts Full duplex RS-232C communication link Five digit oxygen concentration LED display 2x20 alphanumeric vacuum fluorescent display for set up and diagnostics Brass sample passages and fittings Universal power supply: VAC / Hz Remote calibration digital inputs OPTIONS - C Electronically operated cal/zero valves SPECIFICATIONS Ranges: Calibration range: 0-25% Accuracy: 3 user selectable ranges; typical ranges 0-5% to 0-100%; autoranging with ID output (lower ranges available) ±1% of full scale at constant temperature; ±5% of full scale over operating temperature range on factory default analysis ranges, once thermal equilibrium has been achieved Response time: 90% of full scale in < 10 seconds at 77 F (25 C) Linearity: Zero drift: Span drift: Repeatability: 1% O2 1% O2 / 1 month 1% FS / 1 month 0.1% / FS Operating temp: Outputs: Alarms: 32 to 113 F (0 to 45 C) Two 0-1 VDC & two 4-20 madc isolated (concentration and range ID) One system-failure alarm contact to detect power failure; two adjustable concentration threshold alarms with fully programmable setpoints. Analysis display: 5 digit red LED, 3/5 high numerals Menu display: Digital interface: 20 character, 2 line vacuum fluorescent Full duplex RS-232C communications port Power requirements: Universal AC input ranges, 100 to 240 VAC, 50 / 60 Hz, 70 watts max Oxygen sensor: Sample connections: Area classification: Dimensions: Paramagnetic User specified 1/4 or 6mm fittings General purpose flush mounted 6.96 H x 8.7 W x 12.2 L (control unit) Sample Gas Conditioning Requirements Sample inlet pressure: Sample flow: Sample dewpoint: 5 to 20 psig (regulate to fixed inlet pressure) 1 to 2 SCFH Sample temperature: 0 to 50 C Detector wetted parts: Non-condensing at ambient temperature Glass, steel, gold, viton, acrylic glass, epoxy resin For complete turnkey systems, please contact Teledyne or your local representative TELEDYNE ANALYTICAL INSTRUMENTS A Teledyne Technologies Company Chestnut Street City of Industry, California 91748, USA Warranty Instrument is warranted for 1 year against defects in material or workmanship NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice. TEL: or FAX: ask_tai@teledyne.com Teledyne Analytical Instruments, A Teledyne Technologies Company. All rights reserved. Printed in the USA. 08/05LD

12 TELEDYNE ANALYTICAL INSTRUMENTS MODEL 3020M Explosion Proof Paramagnetic Oxygen Analyzer Fully explosion proof enclosure Microprocessor based Exceptional performance, price value Advanced paramagnetic sensor Designed for petrochemical industry Teledyne s Model 3020M Paramagnetic Percent Oxygen Analyzer is a versatile, microprocessor based instrument specifically designed to detect oxygen in a variety of gases. The 3020M is a precise, cost effective instrument capable of measuring percent oxygen in as low as the 0-1% range. Drawing on the solid performance of Teledyne s highly successful 3000 series control platform, the 3020M provides the user with a wide variety of features and options to satisfy virtually any application. PRINCIPLE OF MEASUREMENT The physical property distinguishing oxygen from other gases is its paramagnetism which is significantly greater than that of common gases. Consequently the molecules of oxygen are attracted by strong magnetic fields which can be used in detection. A paramagnetic sensor consists of two spheres arranged in the form of a dumbbell suspended in a symmetrical, nonuniform magnetic field. When the surrounding gas contains oxygen, the dumbbell spheres rotate out of the magnetic field by the relatively strong attraction of oxygen. A light beam focused on a mirror attached to the dumbbell reflects asymmetrically onto two photo diodes resulting in a voltage shift. The voltage difference produces a current used to drive the dumbbells back to the original position. The current flow required to maintain the null position is directly proportional to the oxygen concentration and is shown linearly in volume percent oxygen in the display. Properly maintained paramagnetic sensors last for years with little or no attention making them ideal for critical measurements in the low percent range. FLEXIBILITY The 3020M offers three dynamic, user-configurable ranges plus autoranging, and can be calibrated in any range. The instrument is linear on all three ranges, eliminating the need to recalibrate while switching between ranges. The analyzer comes standard with an isolated 4-20 madc output for oxygen concentration and range identification. Additionally, a bi-directional RS-232C serial communication interface provides for remote monitoring and control of span and zero functions. Teledyne provides auto-calibration capabilities as a standard feature in the 3000 series platform. APPLICATIONS This instrument is designed specifically for the detection of percent oxygen in petrochemical applications for process control, quality assurance, and safety related purposes. Typical petrochemical plants requiring the 3020M are: Ethyl Benzene / Styrene Monomer (EB / SM) Pure Terephthalic Acid (PTA) Caprolactum Phenol / Cumene Polycarbonate Polyethylene Polystyrene Ethylene Oxide / Ethylene Glycol (EO / EG) Methyl Methacrylate (MMA) Ammonia / Urea Fertilizer Refinery FCC Unit and flare gas applications Marine Vapor Recovery (MVR) THE LEADER IN OXYGEN The 3020M can be ordered as a standard unit or as part of a larger analytical system. With over 50 years of analytical instrument experience, Teledyne supplies sensors, custom engineered analyzers and complete monitoring systems to satisfy unique applications. From portables to on-line units, in microprocessor based or analog configurations, no other manufacturer comes close to matching Teledyne s breadth of instrumentation. ADVANTAGES Linearity of analysis across three user-selectable ranges Autoranging to follow process upsets Auto-calibration electronics standard No purge gas requirements Built for Reliability and Performance

13 MODEL 3020M PARAMAGNETIC OXYGEN ANALYZER STANDARD FEATURES Proven, robust paramagnetic sensor Explosion proof NEMA 4/7 rated enclosure (Class I, Div 1, Group B) Three user-selectable ranges plus cal range Signal and Range ID output: isolated 4-20 madc Programmable autoranging Two fully adjustable concentration alarm set points with programmable relay functions, Form C contacts, 3A resistive Calibration contact span/zero, Form A normally open contact, 3A resistive Self diagnostics with Form C failure alarm contacts Full duplex RS-232C communication link Five digit oxygen concentration LED display 2x20 alphanumeric vacuum fluorescent display for set up and diagnostics Stainless steel sample passages and fittings Universal power supply: VAC / Hz Remote calibration digital inputs OPTIONS -C Electronically operated cal/zero valves -F Flame arrestors for Class I, Div 1, Group C/D service -G Flame arrestors for Class I, Div 1, Group C/D service with cal valves -H Flame arrestors for Group B (hydrogen) service -I Flame arrestors for Group B service with cal valves SPECIFICATIONS Ranges: Calibration range: 0-25% 3 user selectable ranges; typical ranges 0-5% to 0-100%; autoranging with ID output (lower ranges available) Accuracy: ±1% of full scale at constant temperature; ±5% of full scale over operating temperature range on factory default analysis ranges, once thermal equilibrium has been achieved. Response time: Linearity: 90% of full scale in < 10 seconds at 77 F (25 C) 0.1% O2 Zero drift: Span drift: Repeatability: Operating temp: Outputs: Alarms: Analysis display: Menu display: Digital interface: 0.05% O2 / 1 Month 1% FS / 1 Month 0.1% / FS 32 to 113 F (0 to 45 C) Two 0-1 VDC & two 4-20 madc isolated (concentration and range ID) One system-failure alarm contact to detect power failure; two adjustable concentration threshold alarms with fully programmable setpoints. 5 digit red LED, 3/5" high numerals 20 character, 2 line vacuum fluorescent Full duplex RS-232C communications port Power requirements: Universal AC input ranges, 100 to 240 VAC, 50 / 60 Hz, 70 watts max Oxygen sensor: Sample connections: Enclosure: Mounting: Dimensions: Paramagnetic User specified 1/4" or 6mm fittings Explosion proof U/L and CSA listed housing for Class I, Div 1, Group B, C & D service; NEMA 4/7 rated with baked powder epoxy finish for corrosion resistance Bulkhead mount 15.25" W x 25.63" H x 11" D ( mm x 651 mm x mm) Sample Gas Conditioning Requirements Sample inlet pressure: 5 to 20 psig (regulate to fixed inlet pressure) Sample flow: Sample dewpoint: 1 to 2 SCFH Sample temperature: 0 to 50 C Non-condensing at ambient temperature Detector wetted parts: Glass, steel, gold, viton, acrylic glass, epoxy resin For complete turnkey systems, please contact Teledyne or your local representative TELEDYNE ANALYTICAL INSTRUMENTS A Teledyne Technologies Company Chestnut Street City of Industry, California 91748, USA Warranty Instrument is warranted for 1 year against defects in material or workmanship NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice. TEL: or FAX: ask_tai@teledyne.com Teledyne Analytical Instruments, A Teledyne Technologies Company. All rights reserved. Printed in the USA. 11/05LD

14 Technical Data Measuring Principle: Paramagnetic behaviour of oxygen Magnos 16 Sample Component: Oxygen (O 2 ) Measuring Ranges: Smallest measuring range: Vol.-% O 2 Largest measuring range: Vol.-% O 2 Measuring range switching ratio: 1:100 Max. measuring range suppression 1:100, e. g Vol.-% O 2 Calibration: Zero- and end-point calibration with nitrogen (N 2 ) and air or sample gas mixture Single-point calibration with room air Automatic calibration via built-in pneumatic module or external valves Magnos 16 based on the magnetomechanical measuring principle the analyzer is ideally suited for oxygen purity measurement, process gas measurements and inert gas blanketing. In emission measurements the Magnos 16 fulfills the special requirements, e.g. TA-Luft (German Federal Air Purity) Regulations, German 13. and 17. BImSchV Regulations. The ability to freely select measuring ranges and measure highly suppressed ranges means that the analyzer can be easily adapted to specific tasks. Even measurements for safety are no problem monitoring the sample flow rate through the measuring chamber always ensures that the current oxygen concentration is being measured. Mounting the analyzer in a flame-proof housing (EEx d) allows use in hazardous areas, zone 1. The standard unit is certified for Class I, Division 2 hazardous areas. Another advantage of the analyzer module is its short T 90 response time. Calibration of the zero point is only required once a month using air or nitrogen. Magnos 17 based on the thermomagnetical measuring principle the analyzer is used mainly in the analysis of flue gas including mixed fuel boilers, incinerators, cement flue gas and roasting gas. The robust measuring cell means the Magnos 17 is especially insensitive to vibrations and shocks. The range of oxygen analyzer modules is complimented by an electrochemical cell. Magnos 17 Sample Component: Oxygen (O 2 ) in flue gases or in nitrogen (N 2 ) Measuring Ranges: Smallest measuring range: Vol.-% O 2 Largest measuring range: Vol.-% O 2 Measuring range switching ratio: 1:33 Calibration: Zero-point calibration with oxygen-free process gas or substitute gas End-point calibration with process gas having a known oxygen concentration or with substitute gas Automatic calibration via built-in pneumatic module or external valves ABB Automation Analytical Division Stierstädter Straße 5, D Frankfurt a. M., 50/24-04 EN 10.99

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in: XMO2 Panametrics Smart Oxygen Analyzer Applications An oxygen transmitter for use in: Inerting/blanketing liquid storage tanks Reactor feed gases Centrifuge gases Catalyst regeneration Solvent recovery

More information

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES PROCESS ANALYSERS DF-550E The DF-550E Nano Trace oxygen analyser is a Coulometric sensor based analyser designed to measure oxygen as a contaminant at ultra trace levels in ultra high purity electronic

More information

780S Ultra High Purity Series

780S Ultra High Purity Series Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board

More information

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES PROCESS ANALYSERS DF-310E The DF-310E is a Coulometric sensor based oxygen analyzer designed to measure trace and percent level oxygen in pure and multi-gas backgrounds for process and quality control

More information

EasyLine Continuous Gas Analyzers. So smart, they re simple

EasyLine Continuous Gas Analyzers. So smart, they re simple EasyLine Continuous Gas Analyzers So smart, they re simple Reliable Economic Powerful EasyLine is both a powerful and affordable line of instruments for the monitoring of gas concentrations in numerous

More information

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling SERVOPRO Plasma The SERVOPRO Plasma is a Plasma Emission Detector based analyser designed to continuously measure Nitrogen in pure Argon for process and quality control in Argon production within Cryogenic

More information

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272) Manual Addendum Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272) P/N M07273 DATE 06/11/13 TELEDYNE ELECTRONIC TECHNOLOGIES Analytical Instruments 16830 Chestnut Street City of Industry,

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring An Company Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring Oxygen

More information

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental

More information

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas ABB MEASUREMENT & ANALYTICS Continuous gas analyzers EL3060 The specialists for hazardous areas The specialists for hazardous areas ABB Analytical possesses decades of experience in the area of explosion

More information

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved LPS Product Guide N2-GEN LPSTM LPS Series Nitrogen Generators N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved - 2014 p 888 526 6284 e info@southteksystems.com w www.southteksystems.com

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

Features. Description

Features. Description Features Fast response flow meter ideal for inert gas and liquid mass flow measurement applications Smart electronics permit field adjustment of critical flow meter settings Field validation of flow meter

More information

Autocalibration Systems For In Situ Oxygen Analyzers

Autocalibration Systems For In Situ Oxygen Analyzers Product Data Sheet PDS 106-340AC SPS 4000, IMPS 4000, and MPS 3000 January, 1999 Autocalibration Systems For In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from

More information

Precision pressure sensor Basic version Model CPT6020

Precision pressure sensor Basic version Model CPT6020 Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications

More information

Model EXAxt AV550G. Averaging Oxygen Analyzer

Model EXAxt AV550G. Averaging Oxygen Analyzer Model EXAxt AV550G Averaging Oxygen Analyzer Oxygen Measurement and Flyash Oxygen % vs cell EMF The O2 mation, model AV550, averaging oxygen analyzer was designed with a focus Calibration 1 on practical

More information

analytical bulk flow distance FLOW level pressure temperature industrial communication

analytical bulk flow distance FLOW level pressure temperature industrial communication analytical bulk flow distance level pressure temperature industrial communication isolv THERMAL MASS METER Measuring Principle Self-heated Sensor Reference Sensor isolv Thermal Mass Flow Meters have two

More information

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases P r o d u c t i n f o r m at i o n EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total

More information

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas ABB MEASUREMENT & ANALYTICS Continuous gas analyzers EL3060 The specialists for hazardous areas The specialists for hazardous areas ABB Analytics possesses decades of experience in the area of explosion

More information

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at

More information

LFE OEM TCD - Thermal Conductivity Detector

LFE OEM TCD - Thermal Conductivity Detector LFE OEM TCD - Thermal Conductivity Detector Key features Quick response - T90 3 sec Extremely suppressed ranges High corrosion resistance High temperature capability up to 180 C Infallible containment

More information

Autocalibration Systems for In Situ Oxygen Analyzers

Autocalibration Systems for In Situ Oxygen Analyzers Product Data Sheet PDS 106-340AC.A01 February, 2006 SPS 4001B, IMPS 4000 and MPS 3000 Autocalibration Systems for In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging

More information

Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. siemens.

Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. siemens. Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. Easier Than Ever SIPROCESS GA700 The New Generation of Continuous Gas Analytics.

More information

Ultra High Purity Model 780S

Ultra High Purity Model 780S Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no separate temperature or pressure inputs required Built-in flow conditioner which eliminates velocity-profile

More information

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Supplementary Operator s Manual 42/24-14 EN Rev. 3 Advance Optima Continuous Gas Analyzers AO2000 Series with Uras26, Magnos206, Caldos25, Caldos27 Designed per Category 3G for Measurement of Flammable Gases ( Safety Concept ) and Non-flammable Gases Supplementary

More information

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing) 1 X-Flow Mass Flow Controller Flow Range from 0.8 ml/min to 20 l/min Target Markets Laboratory and Process Instrumentation Pharma / Bio-Pharma Equipment Air Quality Monitoring Systems Furnace and Coatings

More information

High-speed pressure sensor Model CPT6140

High-speed pressure sensor Model CPT6140 Calibration technology High-speed pressure sensor Model CPT6140 WIKA data sheet CT 25.11 Applications Testing technology Calibration technology Laboratories and maintenance shops Leak and burst applications

More information

Oxygen & Binary Gas Measurement and Analysis

Oxygen & Binary Gas Measurement and Analysis Oxygen & Binary Gas Measurement and Analysis Protect processes, reduce costs and maintain quality Oxygen & Binary Gas Measurement and Analysis A range of quality process analyzers from experts in control

More information

MODEL GENERA PURGE TURBINE INSTR DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.

MODEL GENERA PURGE TURBINE INSTR DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM. 275R MODEL 275R POR ORTABLE TURBINE GENERA ENERATOR PURGE GAS ANAL NALYZER INSTR NSTRUCTION MANU ANUAL AL DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.

More information

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions

More information

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions L 100 Bubble-Tube Level System Installation, Operation and Maintenance Instructions Figure 1 Contents Section Description Page 1.0 Introduction 2 2.0 Specifications 3 3.0 Installation 3 4.0 Warranty 6

More information

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions

More information

Porter Analytical & Industrial Products

Porter Analytical & Industrial Products Porter Analytical & Industrial Products Porter Analytical & Industrial Products Engineered to Excel in Critical Applications The Porter Instrument Division of Parker Hannifin Corporation is a leading manufacturer

More information

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex Data Sheet DS-TMF-586Ex-MFC-eng TMF-Zone Brooks TMF-Zone Models 586-Ex/5864-Ex Customer Benefits Assured process accuracy and repeatability Long-term reliability Reduced maintenance CE certified Improved

More information

OPERATING INSTRUCTIONS FOR MODEL

OPERATING INSTRUCTIONS FOR MODEL Turbine Generator Gas Analyzer OPERATING INSTRUCTIONS FOR MODEL 2750 Turbine Generator Gas Analyzer P/N M76700 4/09/2012 DANGER Toxic gases and or flammable liquids may be present in this monitoring system.

More information

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER THERMAL MASS FLOW METER s Series Thermal Mass Flow Meters provide accurate and reliable flow measurement for natural gas, compressed air, and other industrial gas applications. Natural Gas Compressed Air

More information

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use Data sheet Katharometers The ideal equipment for Process Monitoring and Control Designed for continuous industrial use Long working life Suitable for flammable gases CENELEC certified (ATEX) to EExia IIC

More information

Analyze IT EL6010 Gas Analyzers in Category 2G

Analyze IT EL6010 Gas Analyzers in Category 2G Data Sheet Analyze IT EL6010 Gas Analyzers in Category 2G EL6010-Uras14 Infrared Analyzer Unit EL6010-Magnos106 Oxygen Analyzer Unit EL6010-Caldos17 Thermal Conductivity Analyzer Unit EL6010-CU Control

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6 LT GasAnalyzer LT GasAnalyzer Page 1 of 6 LT GasAnalyzer Disturbances in the protective gas supply can cause production losses or affect product quality. In the worst case, it even can endanger life and

More information

Over 20,000 Strain Gage Target flowmeters installed since 1952.

Over 20,000 Strain Gage Target flowmeters installed since 1952. Over 20,000 Strain Gage Target flowmeters installed since 1952. Liquid, gases, superheated and saturated steam from -320 to 500 O F and up to 15,000 psi. No frictional moving parts. Designed to withstand

More information

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS Using state-of-the-art measuring and microprocessor technologies, Advanced has assembled a series of systems which can measure mass

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers ABB MEASUREMENT & ANALYTICS DATA SHEET Advance Optima AO2000 Series Continuous gas analyzers 2 AO2000 CONTINUOUS GAS ANALYZERS DS/AO2000-EN REV. A Measurement made easy Modular continuous gas analyzers

More information

Mass Flow Controllers

Mass Flow Controllers Mass Flow Meters & Controllers HFM-D-3A & 305A Mass Flow Meters HFC-D-3A & 307A Mass Flow Controllers FEATURES Range 0-25 slm to 0-2500 slm (N 2 Equivalent) Excellent Accuracy ±(0.5% of Reading + 0.2%

More information

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Temperature controlled, multi-technique volumetric

More information

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Universal pycnometer, no

More information

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Product Data Sheet PDS 106-581.A01 September, 2007 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: ATEX, Zone 1, EEx ia IIC T4 Class I, Div. I, Gr. A, B, C, D T4 Operates

More information

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI GP1 & GP2 Electropneumatic Regulators FOR PRESSURE CONTROL TO 1, PSI GP1 & GP2 Functional Description The GP series control valve is an electronic pressure regulator designed to precisely control the pressure

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers ABB MEASUREMENT & ANALYTICS DATA SHEET Advance Optima AO2000 Series Continuous gas analyzers 2 AO2000 CONTINUOUS GAS ANALYZERS DS/AO2000-EN REV. B Measurement made easy Modular continuous gas analyzers

More information

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values Operations Manual Please read, understand, and follow these instructions before operating this equipment.

More information

Micro Motion 3098 Gas Specific Gravity Meter

Micro Motion 3098 Gas Specific Gravity Meter Product Data Sheet PS-001188, Rev. B April 2009 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.

More information

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER Features ±0.01% FS Measurement & Control Accuracy ±0.001% /ºC Thermal Stability Pressure Ranges from ±1 psid to 1200 psia Applications Barometric Measurement

More information

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters Features Include Base accuracy : ±0.075% Span limits

More information

Data Sheet 10/ EN July 2007

Data Sheet 10/ EN July 2007 Advance Optima Continuous Gas Analyzers AO2000 Series Models AO2020, AO2040 Data Sheet 10/24-1.20 EN July 2007 One central unit and various analyzer modules with common controls with a common connection

More information

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM 40 Series Extractive Gas Analyser CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O Extractive low cost, low maintenance devices for continuous

More information

Design Features. General Description

Design Features. General Description Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design

More information

LT GasAnalyzer beyond standards

LT GasAnalyzer beyond standards beyond standards LT GASANALYZER Highly performant analyzer for measuring the concentration of technical gases based on a thermal conductivity sensor, an infrared sensor or a para-magnetic sensor. Combinations

More information

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers 800 Series Mass Flow Meters and Controllers High Performance Mass Flow Meters and Controllers WHY MASS FLOW? In most processes it is mass, not volume, which is the critical variable. Volumetric flow measurements

More information

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale EPR-3000 High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale General Specifications PRECISE CONTROL UP TO 3000 PSI The Equilibar EPR-3000 dual valve pressure controller

More information

Industrial pressure controller Model CPC4000

Industrial pressure controller Model CPC4000 Calibration technology Industrial pressure controller Model CPC4000 WIKA data sheet CT 27.40 Applications Oil and gas industry Industry (laboratory, workshop and production) Transmitter and pressure gauge

More information

Advance Optima AO2000 Series Continuous gas analyzers Models AO2020, AO2040. Measurement made easy. Modular continuous gas analyzers

Advance Optima AO2000 Series Continuous gas analyzers Models AO2020, AO2040. Measurement made easy. Modular continuous gas analyzers Data sheet 10/24-1.20 EN Rev. 8 Advance Optima AO2000 Series Continuous gas analyzers Models AO2020, AO2040 Measurement made easy Modular continuous gas analyzers One central unit and various analyzer

More information

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications GE Sensing & Inspection Technologies 7250 Sys Ruska Multi-Range Pressure Calibration System Features Fully integrated multi-range pressure test and calibration systems Select either an eight range or the

More information

Mass Flowmeters. Mass Flowmeters for Gases

Mass Flowmeters. Mass Flowmeters for Gases Mass Flowmeters Mass Flowmeters for Gases Fast, Accurate, Low Pressure Drop for critical measurement applications! Flow (Std l/min) Response to a step change in flowrate 300 200 100 4 Milliseconds 63%

More information

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

This multi-functional device allows the determination of up to six quality parameters with only one measurement: Devices for determination of the gas quality For verification of several parameters in one operation 3-038-R... Multi-Analyser without return system 3-038R-R... Multi-Analyser with return system This multi-functional

More information

GasSense NDIR User Manual

GasSense NDIR User Manual INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION

More information

HumiSys HF High Flow RH Generator

HumiSys HF High Flow RH Generator HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. EasyLine EL3000 Series Continuous gas analyzers

ABB MEASUREMENT & ANALYTICS DATA SHEET. EasyLine EL3000 Series Continuous gas analyzers ABB MEASUREMENT & ANALYTICS DATA SHEET EasyLine EL3000 Series Continuous gas analyzers 2 EL3000 CONTINUOUS GAS ANALYZERS DS/EL3000-EN REV. A Measurement made easy So smart, they re simple A wide variety

More information

Overview. Front Panel: Keypad and Display

Overview. Front Panel: Keypad and Display Overview The GA-200B is an analyzer that integrates a gas sampling system with sensors to measure and display the concentrations of oxygen and carbon dioxide in a sample as the percentage of a gas in the

More information

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING Blair Chalpin Charles A. Matthews Mechanical Design Engineer Product Support Manager Scanivalve Corp Scanivalve Corp Liberty Lake, WA

More information

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司 X-Flow Mass Flow Controller 2 Highlights Parker Hannifin Precision Fluidics Division is excited to introduce X-Flow, a new easy to use general purpose mass flow controller for your instrument, lab, or

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx Design Features VORTEX IN-LINE FLOW METERS For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up to 30.5 m (0 ft). n No fluid

More information

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology: Title: Comparison of Chemical Sensor and NDIR Technologies TSN Number: 25 File:\\MII- SRV1\Metron\Bridge_Analyzers\Customer_Service_Documentation\White_Papers\25_G en EGA NDIR vs Chemical Sensor.docx Created

More information

Technical Data Sheet MF010-O-LC

Technical Data Sheet MF010-O-LC Technical Data Sheet MF010-O-LC - 1 - 1. Properties The oxygen measuring system MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 C. It is particularly suitable for the

More information

CO2 incubator with additional process controls

CO2 incubator with additional process controls CB series 150 C2 incubators C2 incubator with additional process controls The BINDER CB series C2 incubator is the premium class among the C2 incubators. It is suitable for all sensitive incubation applications

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see mvx Principles of Operation VX No moving parts to wear or fail. Electronics can be remotely mounted up to 30.5 m (0 ft). No fluid

More information

The Ins and Outs of I/P Transducers

The Ins and Outs of I/P Transducers The Ins and Outs of I/P Transducers By Mark B. Levine, ControlAir Inc. General description I/P transducers are versatile instruments that use an electrical control signal to proportionally regulate gas

More information

Digital dead-weight tester Model CPD8500

Digital dead-weight tester Model CPD8500 Calibration Digital dead-weight tester Model CPD8500 WIKA data sheet CT 32.05 Applications Calibration laboratories Avionics/Aerospace equipment manufacturers Precision pressure sensor manufacturers Calibration

More information

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions Continuous Gas Analysis In situ laser gas analyzers Compact Operating Instructions 1 LDS 6 TÜV/MCERTS certified analyzers for NH3/H2O, NH3 and H2O 1.1 Operation requirements Please observe the following:

More information

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER 1250 METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER 1.0 Scope and Application. 1.1 Analytes. Analyte CAS No. Sensitivity Total Organic Compounds N/A

More information

FTC130 Transmitter. Operating Manual

FTC130 Transmitter. Operating Manual Seite 1 von 11 FTC130 Transmitter Fast Thermal Conductivity Analyzer Operating Manual 1.09KD180724CWI1V05 Messkonzept GmbH Seite 2 von 11 1. Intended Use... 3 2. Description... 4 3. Measuring gases and

More information

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel: PERMA PURE INSTRUCTION MANUAL FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model 3300 Version 4.06 Perma Pure LLC Tel: 732-244-0010 P.O. Box 2105, 8 Executive Drive Tel: 800-337-3762 (toll free US)

More information

Continuous gas analysis ULTRAMAT 23 Supplement 2 for Operating Instructions C79000-G52xx- C216-03

Continuous gas analysis ULTRAMAT 23 Supplement 2 for Operating Instructions C79000-G52xx- C216-03 Continuous gas analysis ULTRAMAT 23 Supplement 2 for Operating Instructions C79000-G52xx- C216-03 Product Information Legal information Warning notice system This manual contains notices you have to observe

More information

SERVOTOUGH Oxy (1900)

SERVOTOUGH Oxy (1900) PROCESS ANALYSERS SERVOTOUGH (1900) The SERVOTOUGH offers reliability, flexibility, simplicity of use and installation for applications in the most hazardous and challenging of environments. The worlds

More information

Steel-Mass Model 640S

Steel-Mass Model 640S Smart Insertion Thermal Gas Mass Flow Meter Features Direct mass flow monitoring eliminates need for seperate temperature and pressure inputs Accuracy +/- 1% of reading plus 0.5% of full scale Patented

More information

PM105 PRESSURE METER USER S MANUAL

PM105 PRESSURE METER USER S MANUAL PM105 PRESSURE METER USER S MANUAL Manual revision: 15 March, 2001 SCSMANP015 Copyrighted 2001 Thank you for purchasing a Tek Know pressure meter. The Tek Know products are manufactured by Scan-Sense AS

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the Endura AZ20 / AZ30 measuring system Manufactured by: ABB Ltd Oldends Lane Stonehouse Gloucestershire GL10 3TA has been assessed by Sira Certification

More information

High Purity & Ultra High Purity

High Purity & Ultra High Purity Solar and Semiconductor High Purity & Ultra High Purity Pressure and Weight Measurement R Electronic Pressure Measurement High Purity & Ultra High Purity - Pressure and Weight Measurement WIKA offers a

More information

Laser Gas Analyzer LG2000. The Laser Technologies

Laser Gas Analyzer LG2000. The Laser Technologies Laser Gas Analyzer LG2000 The Laser Technologies LG 2000 Series Laser Gas Analyzer Utilizing proprietary technologies of Tunable Diode Laser Absorption Spectroscopy (TDLAS), the LG 2000 system to satisfy

More information

BAPI Pressure Line of Products - FAQs

BAPI Pressure Line of Products - FAQs Table of Contents 1. Several manufacturers produce pressure transmitters, why should I purchase from BAPI?... p. 2 2. BAPI makes several styles of pressure transmitters. What are the features of each?...

More information

DPC-30 DPC-100. Reference Manual

DPC-30 DPC-100. Reference Manual DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,

More information

Aurora. Moisture Measurement for Industrial Gases. GE Measurement & Control

Aurora. Moisture Measurement for Industrial Gases. GE Measurement & Control GE Measurement & Control Aurora Moisture Measurement for Industrial Gases GE s Aurora analyzer uses tunable diode laser absorption spectroscopy (TDLAS) to rapidly and accurately measure moisture in industrial

More information

CO2 incubator with additional process controls

CO2 incubator with additional process controls CB series 53 C2 Incubators C2 incubator with additional process controls The BINDER CB series C2 incubator is the premium class among the C2 incubators. It is suitable for all sensitive incubation applications

More information

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions Flow Meter with multiple functions for gases and liquids M3 The M-series Flow Meter, with its versatile and user-friendly

More information