CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

Size: px
Start display at page:

Download "CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype"

Transcription

1 (R744) Service Station Presentation Contents Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype Page 1

2 (R744) Service Station Goals Usability Full automatic control Guided Software Integrated Database Printer Internal tank filling Hose compensation Accuracy & Safety High accuracy on oil & refrigerant charge Safety device on key points EU norms comply SAE & UL standards comply Timeline Prototypes Homologation EU & US normative OE & car manufacturer approvals Production Page 2

3 (R744) Service Station Basic functions Fully automatic functions (Reference AC690PRO functions) Secured connection to vehicle service ports Controlled discharge of the system (oil & refrigerant) Evacuation and moisture removal (Vacuum) Accurate recharge of the system (oil & refrigerant) Internal tank filling Safety features Other features Page 3

4 (R744) Service Station Specification Features Max operating pressure Safety switch / pressure relief Pressure gauges Solenoid block Service coupling Service hoses Automatic Hoses lenghts compensation Refrigerant recovery & recycling Compressor Oil separation & drain Vacuum pump Oil injection Electronic charging scale Tank capacity Regulated tank heater AC690PRO R134a Max 1,5 Mpa (SAE J2210 CE PED) 1,5 M pa Yes, EN837 Yes, specific Parker supply R134a SAE J639 R134a, 2,50 meters, SAE J2196 Yes, 2,5-5,0-7,5 10,0 meters Yes, single & multi-pass recycling 1/3 Hp gr / min Yes, 25 ml measuring resolution Yes, dual stage 180 lt / min, 50 microns Yes, 25 ml measuring resolution Yes, 5 grams resolution 20 kg No R744 service station 10 Mpa 10 M pa and / or Pressure gauge Electronic transducers Yes, production version only SAE 2769 R744, SAE 2770 To be define No, outdoor venting No, regulated discharge Yes, To be define Yes, dual stage 180 lt / min, 50 microns Yes, minimum 1 ml measuring resolution Yes, 5 grams resolution 5 kg + external tank Yes Page 4

5 (R744) Service Station Recovery Controled discharge of the system : CO2 recovery flow rate will be limited to prevent freezing and explosive decompression. It should be performed outdoor or indoor if the equipment includes a provision to vent refrigerant outdoor with a flow control valve and a hose. Decompression rate 1 bar to 5 bar / min: it s necessary to verify the best rate in order to have the optimal speed of discharge operation. Page 5

6 (R744) Service Station Vacuum Evacuation and moisture removal : As for R134a, prior to charging R744a, the system should be vacuumed to an absolute pressure of 0.6 kpa or atm for a minimum of 30 minutes. This is equivalent to a vacuum of 755,44 mm Hg or 4000 microns. The vacuum pump oil should be compatible with R744a lubricant. Electronic leak detection under vacuum. Page 6

7 (R744) Service Station Charge Internal vessel with minimized capacity for reaching the PED and safety requirement with connection to external standard R744 refill bottles sourced from the industry (5 bottles). This solution permit also to reach an high accuracy with a scale. The refrigerant charging controlled by an electronic scale with an accuracy of at least +/- 5 gr 400g). The oil charging will be measurable with electronic scale, 1 2 gr resolution Automation with solenoids and electronic devices Page 7

8 (R744) Service Station Safety Full automatic control to avoid operator presence Monitoring of pressures and temperatures on LCD and / or Graphic display (HP & LP, ambient temp, air vent temp..) Heated tank controlled, with thermal safety device to regulate the temperature and pressure switch to disable heating element in case of excessive pressure. Safety pressure relief at the key points of the circuit. Automatic vehicle pressure detection (alarm) and safety pressure relief. No internal access for regular maintenance. (vacuum pump oil...) Sleeve quick couplers that don t permit the detaching if there is pressure on the connections CO2 sensor and alarm to indicate indoor saturation (To be define) Page 8

9 (R744) Service Station Other features CO2 sensor and alarm to indicate indoor saturation. (To be define) Integrated and updatable database with quantities, viscosity, pressure and temperature specifications per vehicle (Future). Comprehensive diagnostic program (Future). Flushing system is required. After a major repair & prior charging R744a, the system should be flushed from all contamination in way to remove particles and to set the correct quantity of lubricant (Future). Page 9

KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS

KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS THE STANDARD IN INFORMATION, EQUIPMENT AND DIAGNOSTICS SYSTEMS h t t p : / / d i a g n o s t i c s. s n a p o n. c o. u k KOOLKARE INTRODUCTION

More information

KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS

KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS THE STANDARD IN INFORMATION, EQUIPMENT AND DIAGNOSTICS SYSTEMS w w w. snapon-equi pment.eu KOOLKARE INTRODUCTION The Sun Koolkare range of Air

More information

FX134, FX1234, FX3030 Problem and Solutions

FX134, FX1234, FX3030 Problem and Solutions FX134, FX1234, FX3030 Problem and Solutions Unit Will Not Power Up Turn the power switch on. The unit LCD will display revision program and filter life within 3 to 5 seconds after turning on unit. If this

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL GS2000 / GS2001 OIL-LESS REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 R01099 GS2000.DOC NRP-OM-GS2000

More information

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80589-02 Table of Contents Components... 2 Test... 4 Recovery/Recycling... 5 Evacuation... 7 Charging...

More information

SURFACE VEHICLE STANDARD

SURFACE VEHICLE STANDARD SURFACE VEHICLE STANDARD New J2788 Issued 1991-12 Revised 1999-02 REV. 2006 Superseding J2210 MAR97 Revision as of April 2006 HFC-134a (R-134a) Recovery/Recycling Equipment and Recovery/Recycling/Recharging

More information

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards. 1. Scope Description of requirements and procedures for compact provers to be used as verification standards. 2. Reference documents Trade Metrology Act SANS1698 3. Policy A. BASIC REQUIREMENTS Compact

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

628 Differential Pressure Decay Leak Tester

628 Differential Pressure Decay Leak Tester 628 Differential Pressure Decay Leak Tester The 628 puts Uson s industry leading differential pressure decay sensitivity in your hands and in your budget with no compromise in quality, reliability, and

More information

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators Selection Guide Automated Calibrators Selection Guide Model Features Range 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP 0.05 to 8 bar.a -0.90 to 25 bar (1.2 to 115 psi.a) (-13 to 375 psi) 0.1 to 26 bar.a

More information

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure

More information

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Additel 761 Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure modules Built-in

More information

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators Selection Guide / Process Calibration Equipment Automated Calibrators Selection Guide Model Features Range Module 1 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP -2.5 to 2.5 mbar (-1 to 1 inh 2 O) -0.95

More information

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure

More information

ADT 761 Automated Pressure Calibrator

ADT 761 Automated Pressure Calibrator 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com With a built-in high performance electronic pump and precision pressure controller,

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

HumiSys HF High Flow RH Generator

HumiSys HF High Flow RH Generator HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously

More information

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-15 OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE

More information

OPERATION MANUAL NTF-60 Plus

OPERATION MANUAL NTF-60 Plus OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)

More information

Refrigerant Recovery, Recycling and Recharging Station

Refrigerant Recovery, Recycling and Recharging Station Operating Manual 34134-2K Refrigerant Recovery, Recycling and Recharging Unit for R-134a 34134-2K Unidad de Recuperación, Reciclado y Recarga para R-134a (Page 21) LISTED 80S2 Recycling Equipment Design

More information

Operating Manual. Model 25200B/25202B Refrigerant Recovery Unit. (Not for use in automotive R-134a applications)

Operating Manual. Model 25200B/25202B Refrigerant Recovery Unit. (Not for use in automotive R-134a applications) Operating Manual Model 25200B/25202B Refrigerant Recovery Unit (Not for use in automotive R-134a applications) ROBINAIR Refrigerant Recovery Unit Model: 25200B /25202B Series Type of Equipment: Recovery

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The LDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

Hydraulic Reliability & Preventive Maintenance Report

Hydraulic Reliability & Preventive Maintenance Report Hydraulic Reliability & Preventive Maintenance Report The following is a report of the test, procedures and recommendations for the in-plant press. This information was recorded on May 10 th and 11 th,

More information

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

This multi-functional device allows the determination of up to six quality parameters with only one measurement: Devices for determination of the gas quality For verification of several parameters in one operation 3-038-R... Multi-Analyser without return system 3-038R-R... Multi-Analyser with return system This multi-functional

More information

Additel 780 Series Pressure Controller

Additel 780 Series Pressure Controller Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale

More information

PPC4E Pressure Controller/Calibrator Superior rangeability and reliability

PPC4E Pressure Controller/Calibrator Superior rangeability and reliability PPC4E Pressure Controller/Calibrator Superior rangeability and reliability Technical Data ± 0.02 % of AutoRanged spans from ± 1 kpa (0.15 psi) to 14 MPa (2,000 psi) The Fluke Calibration PPC4E brings high

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

We measure it. For gas and water installers. testo hpa. bar

We measure it. For gas and water installers. testo hpa. bar Pressure measuring instruments For gas and water installers testo 312-2 hpa testo 312-3 testo 312-4 bar C testo 312-2 / testo 312-3 Pressure meters for gas and water fitters testo 312-2 testo 312-2, fine

More information

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established

More information

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems Name of Property: Address: Phone Number: Inspector: Contract No.: Date: This Report Covers: Monthly Quarterly Annual Other

More information

Vortex Dual. Refrigerant Recovery Machine

Vortex Dual. Refrigerant Recovery Machine O P E R A T I N G M A N U A L Vortex Dual Refrigerant Recovery Machine Table Of Contents Safety First!.................................... 3 EPA Certification................................ 3 Product

More information

Installation and commissioning instructions 255 series and 256 series

Installation and commissioning instructions 255 series and 256 series Installation and commissioning instructions 255 series and 256 series Table of contents 1 General information... 3 1.1 About these instructions... 3 1.2 About this product... 3 1.3 Appropriate usage...

More information

Additions, Revisions, or Updates

Additions, Revisions, or Updates 1 3 01-12 SUBJECT DATE SPN 4334/FMI 2, 3, 4, 7 and SPN 4375/FMI 6 February 2012 Additions, Revisions, or Updates Publication Number / Title Platform Section Title Change SPN 4334/FMI 2 DDC-SVC-MAN-0084

More information

PMI ADVANCED AUTOMATED HYDRAULIC PRESSURE LEAK TESTER APCS-H-60K. Not just Products... Solutions!

PMI ADVANCED AUTOMATED HYDRAULIC PRESSURE LEAK TESTER APCS-H-60K. Not just Products... Solutions! PMI ADVANCED AUTOMATED HYDRAULIC PRESSURE LEAK TESTER APCS-H-60K Not just Products... Solutions! DESCRIPTION The PMI Automated Hydraulic Pressure Leak Tester provides precise pressure generation and control

More information

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI hydro-pac, inc. LX-SERIES Low-Pressure Gas Compressors 1500 to 6000 PSI hydro-pac, inc. LX-SERIES Features Hydro-Pac LX-SERIES Gas Compressors feature: Oil-free non lubricated gas pistons and cylinders

More information

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21 Desiccant Air Breathers DBE Section 3: SCHROEDER INDUSTRIES ACCESSORIES 21 Reservoir Accessories A hydraulic systems reservoir can play a significant role in the ingression of contamination into the system.

More information

HIGH PRESSURE DRILLING FLUID PUMP

HIGH PRESSURE DRILLING FLUID PUMP 1 HDF 200/250-280 HIGH PRESSURE DRILLING FLUID PUMP Dynaset HDF pump gives great water power with small amount of water in relation to its size. As self-priming it is productive in hard environment. Small

More information

Aquavar SOLO 2 Frequently Asked Questions

Aquavar SOLO 2 Frequently Asked Questions Aquavar SOLO 2 Frequently Asked Questions How do I size the Aquavar SOLO 2 for the appropriate pump/motor combination? Can I use a 208 Volt motor? Can I run the Aquavar SOLO 2 up to 80HZ? What are the

More information

SPIROVENT VACUUM DEGASSERS

SPIROVENT VACUUM DEGASSERS SPIROVENT VACUUM DEGASSERS S P I R O V E N T A I R S U P E R I O R FLUID AND GAS There are always a certain amount of gasses in a fluid, dependent on pressure and temperature. The British physicist William

More information

Pressure switch KP-E. Data sheet

Pressure switch KP-E. Data sheet Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches

More information

KEG PUMP. Range of Electric Keg Pumps

KEG PUMP. Range of Electric Keg Pumps KP KEG PUMP Range of Electric Keg Pumps Electric Keg (Drum) Pumps for Grease KEG PUMP Versatile range of Interlube electric grease pumps for industrial and off-road applications The KP keg pump is available

More information

Vehicle-mounted meters, pump supplied

Vehicle-mounted meters, pump supplied Purpose This inspection procedure outline (IPO) defines the minimum tests which must be performed to ensure that basic volumetric measuring devices comply with the legislation. Application Vehicle-mounted

More information

Inert Air (N2) Systems Manual

Inert Air (N2) Systems Manual INSTRUCTION MANUAL Inert Air (N2) Systems Manual N2-MANUAL 2.10 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. GENERAL INFORMATION Positive pressure nitrogen gas pressurizing

More information

CORROSION AT THE AIR-WATER INTERFACE REMOVE THE GAS

CORROSION AT THE AIR-WATER INTERFACE REMOVE THE GAS CORROSION AT THE AIR-WATER INTERFACE There are three (3) physical attributes of oxygen that explain why almost all corrosion in wet pipe fire sprinkler systems occurs in close proximity to trapped air

More information

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction. Bulletin 335 Model DDX-LP Dry Pipe Valve System 8 (200mm) Bulletin 335 Features 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Differential latching clapper-type, lighweight, dependable construction. Low Air Pressurized

More information

ChlorTainer is the safest, most reliable technology available for processing and preventing a chlorine gas release.

ChlorTainer is the safest, most reliable technology available for processing and preventing a chlorine gas release. ChlorTainer is the safest, most reliable technology available for processing and preventing a chlorine gas release. Safest Technology Available ChlorTainer will reduce the area affected by 97%, providing

More information

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER Operation Manual - PN 0017946001 A MENSOR MODEL 73 SHOP AIR BOOSTER Mensor Model 73 Shop Air Booster System (750 psi Version) April 23, 2012 Trademarks / Copyright Mensor is a registered trademark of Mensor

More information

159 mm 154 mm. Subject to changes 10/2012

159 mm 154 mm. Subject to changes 10/2012 Low-pressure calibrator LPX calibrator medium: air / up to 10 bar KELLER pressure calibrators are highly accurate calibration instruments which are available for the following pressure ranges: -0,85 10

More information

Additel 780 Series Pressure Controller

Additel 780 Series Pressure Controller Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale

More information

Pressure Calibrators. Series PC..., PM...

Pressure Calibrators. Series PC..., PM... Pressure Calibrators Series PC..., PM... SIKA-Precision Pressure Calibrators, Series PC..., PM... We help you, if you are under pressure! Pneumatic pressure calibrators PM 25 A, PM 25 D, PM 110 PIC pressure

More information

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER Features ±0.01% FS Measurement & Control Accuracy ±0.001% /ºC Thermal Stability Pressure Ranges from ±1 psid to 1200 psia Applications Barometric Measurement

More information

ASE 7 - Heating, Ventilation, and Air Conditioning. Module 9 Service Tools

ASE 7 - Heating, Ventilation, and Air Conditioning. Module 9 Service Tools ASE 7 - Heating, Ventilation, and Air Conditioning Module 9 Service Acknowledgements General Motors, the IAGMASEP Association Board of Directors, and Raytheon Professional Services, GM's training partner

More information

Portable Oil Lube Air Compressors

Portable Oil Lube Air Compressors Portable Oil Lube Air Compressors 8003631 8003632 0410149 8018968 8018940 Owner s Manual Read and understand operating instructions before use Safety definitions The information listed below should be

More information

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289 3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for

More information

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Test pumps. Pressure sources. Good reasons for proper and reliable calibration Test pumps Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. However, the characteristics of the even

More information

COSMO INSTRUMENTS CO., LTD.

COSMO INSTRUMENTS CO., LTD. Specification Sheet COSMO AIR LEAK TESTER ModelLS-1861 Meets SI Unit Requirement Improved accuracy with the new Master-Preset compensation feature Compensates for environmental changes Improves cycle time

More information

Pressure controls for hydro carbons, zone II applications, Type KPE

Pressure controls for hydro carbons, zone II applications, Type KPE MAKING MODERN LIVING POSSIBLE Technical brochure Pressure controls for hydro carbons, zone II applications, Type KPE KPE pressure controls for use in refrigeration and air conditioning systems with hydrocarbons

More information

M-06 Nitrogen Generator (Nitrogen Making Machine)

M-06 Nitrogen Generator (Nitrogen Making Machine) Guideline No.M-06 (201510) M-06 Nitrogen Generator (Nitrogen Making Machine) Issued date: 20 th October, 2015 China Classification Society Foreword This Guideline is a part of CCS Rules, which contains

More information

OPERATION MANUAL BFX-2

OPERATION MANUAL BFX-2 OPERATION MANUAL BFX-2 Brake Fluid Exchanger IMPORTANT Test drive vehicle after service to verify proper brake system performance. MAHLE Aftermarket Inc., Service Solutions 10 Innovation Drive York, PA

More information

FOAM TANK (1/2) DATA SHEET

FOAM TANK (1/2) DATA SHEET FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 0 PROJECT : QUANTITY : 0 LOCATION : SERVICE : FOAM SYSTEM 0 05 CODE & STANDARDS

More information

OPERATION MANUAL ID900

OPERATION MANUAL ID900 OPERATION MANUAL ID900 Portable Refrigerant Identifier WARNING Liquid Samples will Damage Unit Do not operate if filter has red flecks. Replace filter every 3 months or after every 25 uses. Always have

More information

ACCU-PULSE Installation and Operation Instructions

ACCU-PULSE Installation and Operation Instructions ACCU-PULSE Installation and Operation Instructions Pump Discharge Installation: Chargeable Models Step 1: Mounting Position Mount ACCU-PULSE as close to the pump discharge as possible to absorb the pulse

More information

Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat. Version 5.1

Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat. Version 5.1 Project: Novel Electron Bubble Particle Detector Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat Version 5.1 (Using side filling line) Hand Processed Changes HPC No. Date

More information

REDI CONTROLS, INC. Model RS-503/13-C3. RECOVERY SYSTEM for Very High Pressure Refrigerants R-13, R-23, R-503, & SUVA-95

REDI CONTROLS, INC. Model RS-503/13-C3. RECOVERY SYSTEM for Very High Pressure Refrigerants R-13, R-23, R-503, & SUVA-95 Keep this Manual with the RS-503/13-C3 unit at all times REDI CONTROLS, INC. Operation & Maintenance Manual Model RS-503/13-C3 Literature File No. 1121-01 ARI Certified Patent 5,722,247 RECOVERY SYSTEM

More information

Summary of the MRA LPG Codes of Practice

Summary of the MRA LPG Codes of Practice Summary of the MRA LPG Codes of Practice COP A1 DESIGN and INSTALLATION Code COP A1 deals with above ground installations where LPG is stored under pressure at ambient temperatures in fixed vessels larger

More information

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Copyright, 2005 GPM Hydraulic Consulting, Inc. Troubleshooting and Preventive Maintenance of Hydraulic Systems Learning to Read the Signs of Future System Failures Instructed by: Al Smiley & Alan Dellinger Copyright, 2005 GPM Hydraulic Consulting,

More information

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS Electronic pressure switches ATM/GR CUSTOMER BENEFITS Pressure sensor with integrated switching contacts Modular sensor structure (any process and electrical connections can be combined) Manual readjustment

More information

JORDAIR/BAUER Service Manual

JORDAIR/BAUER Service Manual JORDAIR/BAUER Service Manual Breathing Air Compressor Maintenance Log Doc. ServiceManual Page - 1 SAFETY RELEASE-2016 The following document is prepared to ensure safety of operators and service technicians.

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

Cold-acclimatised pipelines

Cold-acclimatised pipelines Cold-acclimatised pipelines Maintaining flow and pressure when the temperature is low can present serious but manageable challenges. Field instrumentation can help, but it must be deployed and maintained

More information

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes Bulletin 357 Rev. E Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes Bulletin 357 Rev. E Features 1. 2. 3. 4. 5. 6. 7. 8. 9. Differential-type valve, lightweight, dependable construction.

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure

More information

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION OCT2010 STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 87833050

More information

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable Page 1 von 8 Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV 100-575, top reparable Content Seite 0 Legend 2 1 Overview 2 2 Accumulator assembly and installation

More information

CAPITAL CONTROLS SERIES NXT3000

CAPITAL CONTROLS SERIES NXT3000 CAPITAL CONTROLS SERIES NXT3000 Modular design gas feed system with self contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuumoperated, solution-feed gas dispensing

More information

FPG8601 Force Balanced Piston Gauge

FPG8601 Force Balanced Piston Gauge FPG8601 Force Balanced Piston Gauge Reference Level Calibration System for very low pressure Pressure range: 0 to 15 kpa gauge, absolute and absolute differential Standard resolution: 0.010 Pa, high resolution

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE April 9, 2009 Preaction 326a 1. DESCRIPTION Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilizing the Viking G-4000P Deluge Valve. The small profi le, lightweight,

More information

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA. than the water inlet pressure to the concentrate Foam102a 1. DESCRIPTION The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with 3M foam concentrates. This system consists of a standard wet pipe sprinkler

More information

HOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.

HOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane. EASY AND COMFORTABLE TO USE FOR FOOLPROOF OPERATION After the initial setup, there is no need to access the base unit, which frees the operator to concentrate on the sniffing process. All relevant messages

More information

Service station for A/C systems FAST-20x / ECOS-20x / FAST-202YF Use and Instruction Manual

Service station for A/C systems FAST-20x / ECOS-20x / FAST-202YF Use and Instruction Manual Service station for A/C systems FAST-20x / ECOS-20x / FAST-202YF Use and Instruction Manual Index 1. General information for the user...3 1.1 Preliminary instructions/proper use...3 1.2 General safety

More information

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow, Level & Temperature Products for Ultra-Clean Processing P R E C I S I O N S E N S O R S

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow, Level & Temperature Products for Ultra-Clean Processing P R E C I S I O N S E N S O R S SELECTION GUIDE SELECTION GUIDE Pressure, Flow, Level & Temperature Products for Ultra-Clean Processing P R E C I S I O N S E N S O R S S t a i n l e s s S t e e l P r e s s u r e S w i t c h e s f o r

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated

More information

GAS COMPRESSION SYSTEM

GAS COMPRESSION SYSTEM GAS COMPRESSION SYSTEM The gas compression system at HI 376 A consists of two natural gas turbine-driven Compressors (CBA-4020/4070). Both Compressors are needed for the volume of gas being compressed.

More information

High Performance Oilless Commercial Refrigerant Recovery Unit. User Manual Rev. 4 November 2010

High Performance Oilless Commercial Refrigerant Recovery Unit. User Manual Rev. 4 November 2010 High Performance Oilless Commercial Refrigerant Recovery Unit User Manual 2090-0217 Rev. 4 November 2010 Introduction Congratulations on your purchase of the STINGER high performance oilless recovery unit.

More information

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters Features Include Base accuracy : ±0.075% Span limits

More information

Linde Cryogenics. Helium Recovery Systems.

Linde Cryogenics. Helium Recovery Systems. Linde Cryogenics. Helium Recovery Systems. 02 Contents. 3 Introduction 4 Recovery Compressor Options 6 Installation Recovery Piping and Fittings Kits 6 Model 500A Automatic External Helium Purifier 7 Purity

More information

Hand-held pressure calibrator with integrated pump Model CPH6600

Hand-held pressure calibrator with integrated pump Model CPH6600 Calibration technology Hand-held pressure calibrator with integrated pump Model CPH6600 WIKA data sheet CT 16.01 Applications Calibration service companies and service industry Measurement and control

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction

More information

Auto EVAP Quick Start Guide

Auto EVAP Quick Start Guide Auto EVAP Quick Start Guide Pg. 13 Note: Never directly hit or drop the leak detector on the CO2 sensor tip, this will cause the sensor to become damaged! Do not get Leak Seeker Solution directly on the

More information

Nitrogen Tyre Inflator Owner s Manual

Nitrogen Tyre Inflator Owner s Manual Nitrogen Tyre Inflator Owner s Manual Model:PN-8890 Please read this manual carefully before attempting assembly or use. 1 Suit for: Motorcycle, Car, Light Truck, Bus Manual Model Nitrogen Tyre Inflation

More information

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Specification Bulletin (rev.01) Series CH4200 Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Easy, fast& accurate digital with 11 points calibration Laser sensor offering actual feed

More information

COMPRESSOR REPLACEMENT PROCEDURE (R-134A)

COMPRESSOR REPLACEMENT PROCEDURE (R-134A) 372 ROUTE 4 BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 COMPRESSOR REPLACEMENT PROCEDURE (R-134A) [ ] If possible operate the compressor with proper charge for 5 minutes

More information

POWER FLUSH KIT INSTRUCTIONS

POWER FLUSH KIT INSTRUCTIONS 1 GENERAL INFORMATION POWER FLUSH KIT INSTRUCTIONS ACE Power Flush is an ozone-safe solvent engineered specifically for flushing refrigeration and air conditioning systems. Used exactly like the old R-11

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated

More information

VACCUPERM Vacuum chlorine gas dosing systems

VACCUPERM Vacuum chlorine gas dosing systems VACCUPERM Vacuum chlorine gas dosing systems Vaccuperm, precise and safe dosing. www.clorep.es VACCUPERM INTRODUCTION Vaccuperm provides a proven and reliable technology of vacuum gas dosing. Handling,

More information

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve. Foam 302 a 1. DESCRIPTION (Refer to Figure 1 on page 302 e.) The Viking Low-Flow Foam/Water Proportioning System is a UL Listed and FM Approved system, for use with 3M and Viking brand foam concentrate.

More information

SF 6 Product Guide. Gas Analysis Instruments and Accessories

SF 6 Product Guide. Gas Analysis Instruments and Accessories SF 6 Product Guide Gas Analysis Instruments and Accessories Cambridge Sensotec Ltd specialises in the design and manufacture of gas analysis equipment under the Rapidox brand name. Based in the UK, the

More information

A/C SYSTEM DIAGNOSIS

A/C SYSTEM DIAGNOSIS A/C SYSTEM DIAGNOSIS 1988 Jeep Cherokee 1988 AIR CONDITIONING & HEAT A/C General Servicing Diagnostic Procedures Jeep; All Models DIAGNOSTIC PROCEDURES Diagnosis is an important first step in A/C system

More information

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products Saturn Evo SATURN EVO COLOR A N A E S T H E S I A S Y S T E M i n t e l l i g e n t s i m p l i c i t y Manufacturer of high quality anaesthesia products SATURN EVO COLOR PATIENT SAFETY AND USER PATIENT

More information

Protec P3000 (XL) Helium Sniffer Leak Detector

Protec P3000 (XL) Helium Sniffer Leak Detector Protec P3000 (XL) Helium Sniffer Leak Detector AC C U R AT E, R E L I A B L E L E A K DETECTION AT A DISTANCE Sniffer leak detection you can rely on INFICON Protec P3000 and Protec P3000XL Helium Sniffer

More information