1 in84034.txt at Page 1 of 9 SSINS No.: 6835 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C IE INFORMATION NOTICE NO : RESPIRATOR USER WARNING: DEFECTIVE SELF- CONTAINED BREATHING APPARATUS AIR CYLINDERS Addressees: All nuclear power reactor facilities holding an operating license (OL) or construction permit (CP), research and test reactor facilities, fuel cycle licensees, and Priority 1 material licensees. Purpose: This information notice is intended to alert licensees of a serious defect in self-contained breathing apparatus (SCBA) hoop-wrapped aluminum air cylinders rated at 4,500 psi, manufactured under the Department of Transportation (DOT) Exemption DOT-E During refilling operations at a fire department, one cylinder ruptured and injured one person. The National Institute of Occupational Safety and Health (NIOSH) has issued a Respiratory Users Notice, in concert with a DOT Federal Register Notice limiting filling/operating pressure of the affected cylinders to 4,000 psi until further notice. NRC regulations require that only NIOSH-certified respiratory equipment shall be used as emergency devices. Licensees are expected to review the information for applicability to their facilities respiratory protection program and take actions, as required, to maintain NIOSH and DOT certifications for affected equipment and to minimize the probability of catastrophic cylinder failure. Further NRC action may occur after the DOT/NIOSH evaluations are completed and reviewed by the staff. No written response to this notice is required. Description of Circumstances The NRC recently has learned of a serious defect in certain SCBA air

2 in84034.txt at Page 2 of 9 cylinders that caused a rupture of a high-pressure (4,500 psi) air cylinder (rated for 30-minute service) manufactured by Luxfer Limited in 1978 for Scott Aviation. On February 4, 1984, a Scott 4.5 cylinder ruptured at the neck area during a routine refilling at a New York City fire station. The air charging hose that was still attached to the ejected cylinder material, struck the attending fireman. Although not seriously injured, the fireman was severely bruised in the shoulder area, transported to a nearby hospital, and treated and released the same day. The fireman was fortunate that a flying metal fragment did not hit him. This cylinder was not subject to an earlier product recall discussed below. Page 2 of 3 On October 11, 1983, the NRC reported in IE Information Notice 83-68, "Respirator User Warning: Defective Self-Contained Breathing Apparatus Air Cylinders," that several identical Luxfer cylinders manufactured since mid 1982 for Scott and other vendors, had developed cracks around the neck area. Two of these cylinders had ruptured. A product recall directed at a specific manufacturing batch of these hoop-wrapped cylinders had been initiated at that time. Discussion: In response to the recent New York City event and other evidence of cylinder cracking, the DOT Office of Hazardous Material Regulation has amended the exemption to limit the filling pressure for all high pressure (4,500 psi) composite hoop-wrapped cylinders manufactured under Exemption DOT-E The Federal Register Notice (49 FR 39, p see Attachment 1), issued by DOT February 27, 1984, states that Persons owning, using, or otherwise having control over cylinders marked DOT-E , must limit the filling pressure to 4,000 psi, and reduce to 4,000 psi the pressure in cylinders already charged. (emphasis added) NIOSH issued a Respirator User Notice on February 29, 1984 (see Attachment 2), which establishes interim actions to be taken by all users in order to maintain a revised NIOSH certification for the units effective until further DOT action, at which time the certification may be reaffirmed, revised, or revoked. Under this temporarily revised certification (unit rated as a "not less than 25-minute" device), each user should

3 in84034.txt at Page 3 of 9 1. Refill and operate all Luxfer 4,500 psi, 30-minute, hoop-wrapped aluminum cylinders at the reduced pressure of 4,000 psi. 2. Follow the instructions provided by Luxfer for immediate removal from service and physical examination of affected cylinders manufactured before May General recommendations (p. 3 of Attachment 2), issued by NIOSH, offer users sound advice for further reducing the probability of cylinder catastrophic failure and, thereby, increasing worker safety. The interim actions, established by DOT and NIOSH, must be carefully observed to continue the NIOSH certification of the unit as a "not less than 25-minute" device. However, licensees also are reminded that Section III.H of 10 CFR 50, Appendix R (Fire Protection Program for Nuclear Power Facilities Operating Prior to January 1, 1979), requires a rated operating air supply of at least 30-minutes for all SCBA provided for use by fire brigade, damage control parties, and control room personnel. If any affected cylinders are fulfilling 10 CFR 50, Appendix R, requirements, then appropriate compensatory air supplies must be provided. Licensees may choose to request temporary exemption from the 30-minute-rated supply requirement in 10 CFR 50 by contacting their appropriate NRC licensing office. Page 3 of 3 To provide further information, copies of Scott Aviation and Survivair warning letters to their customers are attached (Attachments 3 and 4). If you have any questions concerning this problem, please call the number listed on the appropriate customer warning letter or contact the Regional Administrator of the appropriate NRC Regional Office or this office. Edward L. Jordan, Director Division of Emergency Preparedness and Engineering Response Office of Inspection and Enforcement Technical Contacts: J. E. Wigginton, IE (301)

4 in84034.txt at Page 4 of 9 L. Hendricks, RES (301) Attachments: 1. DOT Federal Register Notice 2. NIOSH Respirator Users Notice 3. Scott Aviation Letter 4. Survivair Letter 5. List of Recently Issued IE Information Notices DEPARTMENT OF HEALTH & HUMAN SERVICES Centers for Disease Control National Institute for Occupational Safety and Health--ALOSH 944 Chestnut Ridge Road Morgantown, WV February 29, 1984 RESPIRATOR USERS NOTICE Attachment 2 Reduced Service Pressure and Physical Examination of 4500 psi Hoop-wrapped Aluminum Cylinders Manufactured by Luxfer USA Ltd., rd Street, Riverside, CA The National Institute for Occupational Safety and Health (NIOSH) has been informed of two recent actions which affect the continued safe use of Luxfer 4500 psi hoop-wrapped aluminum cylinders and the certified status of self contained breathing apparatus incorporating them in their assemblies. (1) The Department of Transportation (DOT) has announced in the Federal Register that in order to accomplish a reduction in the sustained stress in 4500 psi hoop-wrapped aluminum cylinders manufactured by Luxfer under Exemption DOT-E 7235, the maximum cylinder charging pressure must be reduced from 4500 to 4000 psi, effective February 28, This restriction does not apply to 4500 psi fully-wrapped aluminum cylinders. (2) Luxfer USA Ltd. has determined that some 4500 psi/dot-e 7235 hoopwrapped aluminum cylinders manufactured prior to May, 1981, may rupture

5 in84034.txt at Page 5 of 9 or develop longitudinal cracks in the threaded section of the cylinder neck. All such cylinders with manufacturing dates before May, 1981, should be immediately examined in accordance with Luxfer's instructions which may be obtained from the self-contained breathing apparatus manufacturer. Cylinders manufactured after May, 1981, should be examined during the normal hydrostatic test. The following self-contained breathing apparatus certified by the Mine Safety and Health Administration (MSHA) and NIOSH, incorporate 4500 psi/dot- E 7235 hoop-wrapped aluminum cylinders manufactured by Luxfer: Manufacturer Approval No. Model No. AGA TC-13F Clifton Precision TC-13F , -2, -3, -4 (Bendix) MSA TC-13F , National Draeger TC-13F , -201, -202, -203, -204, -205, -206 Siebe Gorman TC-13F Scott TC-13F , -01, -30,-31 TC-13F , -01, -10, ,-21,-30, -31, -40, -41, -50, -51 USD TC-13F , -22; , -22 TC-13F , -01, -02, -03,--20,-21, -22, , -23 Attachment 2 Page 2 of 3 Reduction of Service Pressure Users of self-contained breathing apparatus incorporating any Luxfer 4500 psi/dot-e 7235 hoop-wrapped aluminum cylinders (including those manufactured before and after May, 1981) should immediately reduce the pressure in such cylinders from 4500 to 4000 psi. Pressure reduction may be safely accomplished by attaching the cylinder to a self-contained breathing apparatus and following the breathing apparatus manufacturer's instructions for depressurization until the cylinder pressure has reached 4000 psi. DO NOT OPEN THE VALVE OF ANY PRESSURIZED CYLINDER THAT IS NOT ATTACHED TO A SELF-CONTAINED BREATHING APPARATUS OR OTHER DEVICE THAT WILL SAFELY CONTAIN THE RELEASED PRESSURE. When depleted Luxfer 4500 psi/dot-e 7235 hoop-wrapped aluminum cylinders are recharged after use, the maximum pressure of 4000 psi must not be exceeded.

6 in84034.txt at Page 6 of 9 Status of MSHA/NIOSH Certifications The reduction in maximum service pressure from 4500 to 4000 psi affects the MSHA/NIOSH certification of the self-contained breathing apparatus to the extent that they will no longer meet the service time requirements of Title 30 Code of Federal Regulations Part 11 for a 30-minute duration apparatus. Therefore it is necessary for NIOSH to temporarily revise the certifications for these apparatus to continue their certified status. After consideration of the several factors involved in the maximum pressure reductions, NIOSH has decided to temporarily reduce the certification rated service time for each of the apparatus listed above, from 30 minutes to not less than 25 minutes. The revised certifications will be effective until further action is taken by DOT, at which time they will be further revised, canceled, or made official by publication in the Federal Register. This temporary change does not otherwise affect the certifications of these apparatus. Respirator users should immediately take the reduced service time into consideration in their continued use of the apparatus. NIOSH will also temporarily modify the certification to the extent of continuing to require the remaining service time indicator to continue to function within the range of 20 to 25 percent of the original 30-minute service time rating. Therefore, users will observe no change in the amount of service time remaining after initial activation of the remaining service time indicator, and will have the usual service time available for escape from an atmosphere immediately dangerous to life or health. Physical Examination of Cylinders Users of self-contained breathing apparatus incorporating any Luxfer 4500 psi/dot-e 7235 hoop-wrapped aluminum cylinders should immediately observe the manufacturing date of each such cylinder. This date is either stamped on the cylinder neck or is printed on a label which appears on the side of the cylinder under the outer filament wrapping. Hoopwrapped cylinders may be identified by lack of filament winding on the bottom and neck areas. Luxfer recommends that each of their 4500 psi/dot-e 7235 hoop-wrapped aluminum cylinders manufactured before May, 1981, be removed from service, be completely depressurized, devalved, and examined according to Luxfer's instructions which may be obtained from the self-contained breathing apparatus manufacturer. Contact the respirator manufacturer or distributor if you have not received the necessary instructions. Cylinders manufactured after May, 1981, should be examined during the normal hydrostatic test. Attachment 3

7 in84034.txt at Page 7 of 9 February 24, 1984 Dear Customer, Page 1 of 1 Luxfer USA Limited is the manufacturer of the 30-minute duration hoopwrapped high pressure cylinder, Scott P/N , which is used in Air-Pak 4.5 self-contained breathing apparatus. A copy of their letter to us dated February 23, 1984 regarding this cylinder is attached. In view of the situation outlined in the Luxfer letter, it is imperative that you immediately follow the instructions contained in that letter including: - To reduce the service pressure on all 30-minute 4500 psi hoopwrapped cylinders to 4000 psi immediately and to take whatever steps are necessary to assure future fillings will not exceed 4000 psi. - To visually inspect all 30-minute 4500 psi hoop-wrapped cylinders as soon as possible after receipt of Luxfer's recommended inspection procedure. NOTE: These recommended actions are limited to the one cylinder, the 30- minute hoop-wrapped 4500 psi cylinder, Scott P/N , used in Scott's 4.5 Air Paks. If you have any questions, please contact Mr. Dennis Browner at (716) Ext Be assured of our continuing interest in safety and in your full satisfaction with Scott Aviation and our products. We will keep you informed on this matter. Cordially, Lincoln C. Bailey Vice President Sales & Marketing Health/Safety Products Attachment 4 IN Page 1 of 2

8 in84034.txt at Page 8 of 9 Dear Survivair Distributor: February 29, 1984 URGENT SAFETY NOTICE We have been notified by Luxfer and NIOSH of two (2) recent accidents involving Scott 4500 psi hoop wrapped aluminum cylinders manufactured by Luxfer. Whereas no Survivair cylinders have been involved in any accident, Luxfer has determined that some 4500 psi DOT E7235 hoop wrapped aluminum cylinders may rupture or develop longitudinal cracks in the threaded section of the cylinder neck. And even though the threaded section of the Survivair cylinders are significantly different from the Scott cylinders that have been involved in these accidents, you are urged at the direction of the Department of Transportation, NIOSH, Luxfer and Survivair to immediately reduce the service pressure of all Survivair hoop wrapped cylinders in your possession bearing DOT E7235 on the cylinder neck from 4500 psi to 4000 psi. You are also urged to contact all your customers of these cylinders and likewise advise them to immediately reduce the service pressure to 4000 psi. We have been informed by NIOSH that this reduction in service pressure will not void NIOSH certification. However, users should take the reduced service time into consideration in their continued use of the apparatus. OSHA has also informed NIOSH that it will permit use of apparatus with a not less than 25 minute service time rating until further resolution of the problem. Please advise your customers that this reduction in service pressure to 4000 psi will reduce the service time of the Mark I and Mark 2 high pressure units from 30 minutes to approximately 26 minutes. This notice does not affect or request any action on any other Survivair cylinders other than those bearing DOT E7235. These cylinders are only used in Survivair's Mark I (since 1978) and Mark 2 High Pressure, 30 minute units. (since 1983). Attachment 4 Page 2 of 2 A more detailed letter of explanation to follow. Your immediate action and follow up in bringing this matter to the attention of your customers or

9 in84034.txt at Page 9 of 9 known users of these cylinders is greatly appreciated. Failure to do so may potentially result in serious bodily injury, death, and/or property damage. Should you need any further information on this matter please call the Survivair Marketing Department at 714/ Sincerely, Michael M. Chapman Vice President, Marketing

SAFETY ADVISORY: HIGH PRESSURE ALUMINUM SEAMLESS AND ALUMINUM COMPOSITE HOOP-WRAPPED CYLINDERS

SAFETY ADVISORY: HIGH PRESSURE ALUMINUM SEAMLESS AND ALUMINUM COMPOSITE HOOP-WRAPPED CYLINDERS SAFETY ADVISORY: HIGH PRESSURE ALUMINUM SEAMLESS AND ALUMINUM COMPOSITE HOOP-WRAPPED CYLINDERS [Federal Register: July 26, 1994] DEPARTMENT OF TRANSPORTATION Research and Special Programs Administration

More information

URGENT MEDICAL DEVICE RECALL NOTICE

URGENT MEDICAL DEVICE RECALL NOTICE January 31, 2015 URGENT MEDICAL DEVICE RECALL NOTICE ATTN: Regulatory Affairs Manager, Risk Manager, Hospital Administrator, OxyTOTE Distributor, OxyTOTE Wholesaler, Oxygen Service Provider, Health Care

More information

Hazardous Materials Handling High Pressure Cylinders Goals and Objectives

Hazardous Materials Handling High Pressure Cylinders Goals and Objectives Hazardous Materials Handling High Pressure Cylinders Goals and Objectives Safety through Knowledge Handling and Transporting High Pressure Cylinders TRAINING FOR INDIVIDUALS THAT USE BUT DO NOT FILL CYLINDERS

More information

in84061.txt at Page 1 of 6 2/25/00

in84061.txt at  Page 1 of 6  2/25/00 in84061.txt at www.nrc.gov Page 1 of 6 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C. 20555 SSINS No.: 6835 IE INFORMATION NOTICE NO. 84-61: OVEREXPOSURE

More information

EXPIRATION DATE: January 31, 2015

EXPIRATION DATE: January 31, 2015 U.S. Department East Building, PHH 30 of Transportation 1200 New Jersey Avenue, Southeast Pipeline and Hazardous Materials Safety Administration DOT-SP 7235 (TWENTY-THIRD REVISION) Washington, D.C. 20590

More information

INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001

INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001 INSTRUCTION MANUAL FOR EBA 6.5 60 MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001 Page 1 of 20 CONTENTS PAGE INTRODUCTION 3 GENERAL INFORMATION..3

More information

A. Evaluation of the written program

A. Evaluation of the written program A. Evaluation of the written program Begin your audit with an evaluation of the written respiratory protection program. In addition to the operating procedures describing respirator selection and use in

More information

INSTRUCTION MANUAL EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3

INSTRUCTION MANUAL EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3 INSTRUCTION MANUAL FOR THE EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3 Manual Number: NH24053 Revision: A, ECN 3590 December 14, 2015 Page 1 of 13 CONTENTS PAGE INTRODUCTION... 3 GENERAL

More information

Composite. care. cylinder. for responsible paintballers!

Composite. care. cylinder. for responsible paintballers! Composite cylinder care for responsible paintballers! Before you use or fill your composite cylinder, remember: Always... Never... Always have your cylinder inspected or retested if it shows signs of gouges,

More information

Cylinder HAZMAT & Fill Station Operations Compliance. PSI/PCI, Inc. William L. (Bill) High & Mark A. Gresham

Cylinder HAZMAT & Fill Station Operations Compliance. PSI/PCI, Inc. William L. (Bill) High & Mark A. Gresham Cylinder HAZMAT & Fill Station Operations Compliance PSI/PCI, Inc. William L. (Bill) High & Mark A. Gresham Purpose of Hazmat Training Department of Transportation (DOT) Code of Federal Regulations requires

More information

6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE

6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE SCBA MAINTENANCE SCOPE Stoney Point Fire Department Self-contained breathing apparatus provides respiratory protection under conditions of oxygen deficiency or in concentrations of toxic gases immediately

More information

This program shall contain, as a minimum, the following components:

This program shall contain, as a minimum, the following components: Section 1: Introduction 1.1 Policy It is the policy of the Pemberton Township Fire Department to maintain comprehensive safety and occupational health programs predicted upon sound engineering, education,

More information

#121 April 29, 2002 UPDATE OF TECHNICAL BULLETINS

#121 April 29, 2002 UPDATE OF TECHNICAL BULLETINS T E C H N I C A L B U L L E T I N #121 April 29, 2002 UPDATE OF TECHNICAL BULLETINS Products Affected: All Survivair Products Periodically, the Technical Services Department publishes a Technical Bulletin

More information

POLICY AND PROCEDURE DIVISION OF FIRE AND RESCUE SERVICES

POLICY AND PROCEDURE DIVISION OF FIRE AND RESCUE SERVICES Page 1 o Page 1 of 12 RESPIRATORY PROTECTION POLICY Issued by: Fire Chief Policy No. 26-06AM Authority: Code Section 21-2.(d)(4) Effective Date: April 15, 2005 SUMMARY: ADDRESS: STAFF: BACKGROUND: This

More information

Egg Harbor Fire Department and First Responders Standard Operating Policy

Egg Harbor Fire Department and First Responders Standard Operating Policy Egg Harbor Fire Department and First Responders Standard Operating Policy SUBJECT: RESPIRATORY PROTECTION PROGRAM SOP 1206 PURPOSE: SCOPE: To have in place a policy that meets SPS 330.12 (1) (c). This

More information

RevolveAir / Guardian Breathing Air Cylinder Fill Station Operating Instructions

RevolveAir / Guardian Breathing Air Cylinder Fill Station Operating Instructions RevolveAir / Guardian Breathing Air Cylinder Fill Station Operating Instructions Contents IMPORTANT SAFETY INSTRUCTIONS...2 Limited Warranty...3 1 - Introduction...4 Safety Labels...4 Cascade Storage

More information

EXPIRATION DATE: (FOR RENEWAL, SEE 49 CFR ) 1. GRANTEE: Structural Composites Industries (SCI) Pomona, CA

EXPIRATION DATE: (FOR RENEWAL, SEE 49 CFR ) 1. GRANTEE: Structural Composites Industries (SCI) Pomona, CA East Building, PHH-30 1200 New Jersey Avenue S.E. U.S. Department of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety Administration DOT-SP 13583 (NINTH REVISION) EXPIRATION

More information

STATE OF FLORIDA DEPARTMENT OF MILITARY AFFAIRS Office of the Adjutant General St. Francis Barracks, P.O. Box 1008 St. Augustine, Florida

STATE OF FLORIDA DEPARTMENT OF MILITARY AFFAIRS Office of the Adjutant General St. Francis Barracks, P.O. Box 1008 St. Augustine, Florida STATE OF FLORIDA DEPARTMENT OF MILITARY AFFAIRS Office of the Adjutant General St. Francis Barracks, P.O. Box 1008 St. Augustine, Florida 32085-1008 ADMF 19 September 1985 DEPARTMENT OF MILITARY AFFAIRS

More information

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION DUAL SUPPLY REGULATOR ESCAPE CYLINDER VORTEX MAIN INLET PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY

More information

BCF WORK INSTRUCTION Respirator Inspection/Cleaning/Maintenance/Repair and Storage

BCF WORK INSTRUCTION Respirator Inspection/Cleaning/Maintenance/Repair and Storage 1. Purpose This Work Instruction is to be used for the proper inspection, cleaning, maintenance, repair and storage of respirators. 2. Procedure 2.1. General All respirators used in routine situations

More information

PremAire INSTRUCTIONS FOR DUAL-SUPPLY MODE OF OPERATION

PremAire INSTRUCTIONS FOR DUAL-SUPPLY MODE OF OPERATION DUAL SUPPLY REGULATOR ESCAPE CYLINDER VORTEX MAIN INLET PremAire INSTRUCTIONS FOR DUAL-SUPPLY MODE OF OPERATION WARNING This manual must be read carefully by all persons who have who will have the responsibility

More information

EMA, Inc. SITE SAFETY PLAN

EMA, Inc. SITE SAFETY PLAN EMA, Inc. SITE SAFETY PLAN A. SITE DESCRIPTION JOB NAME: JOB NUMBER: DATE: PLAN REVISION NUMBER: SITE ADDRESS: Additional Site / Project Information: B. SCOPE OF WORK 1. 2. 3. 4. 5. 6. C. ONSITE ORGANIZATION

More information

Wayne Chaney Investigator, Southern Region Field Operations

Wayne Chaney Investigator, Southern Region Field Operations Wayne Chaney Investigator, Southern Region Field Operations http://phmsa.dot.gov/hazmat Month/Year - 1 - Agenda Approval requirements for obtaining RINs Cylinder requalification process DOT Inspections

More information

OCENCO M-20.3 Capacity 1 - Closed Circuit Escape Respirator (CCER) Emergency Escape Breathing Device (EEBD)

OCENCO M-20.3 Capacity 1 - Closed Circuit Escape Respirator (CCER) Emergency Escape Breathing Device (EEBD) OCENCO M-20.3 Capacity 1 - Closed Circuit Escape Respirator (CCER) Emergency Escape Breathing Device (EEBD) INSTRUCTION MANUAL - MINING Manual No: N24056 Revision A, ECN 3577 Date: September 21, 2015 OCENCO,

More information

PIPELINE AND HAZARDOUS MATERIAL SAFETY ADMINISTRATION CYLINDER REQUALIFICATION FACILITY INSPECTION REPORT GENERAL INFORMATION

PIPELINE AND HAZARDOUS MATERIAL SAFETY ADMINISTRATION CYLINDER REQUALIFICATION FACILITY INSPECTION REPORT GENERAL INFORMATION PIPELINE AND HAZARDOUS MATERIAL SAFETY ADMINISTRATION CYLINDER REQUALIFICATION FACILITY INSPECTION REPORT Inspection : RIN Number: Company Name and Address: Company Officials: Title: Interviewed GENERAL

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 1716:2012 AS/NZS 1716:2012 Australian/New Zealand Standard Respiratory protective devices AS/NZS 1716:2012 This Joint Australian/New Zealand Standard was prepared by Joint Technical Committee SF-010,

More information

SALEM TOWNSHIP FIRE DEPARTMENT RESPIRATORTY PROTECTION PROGRAM

SALEM TOWNSHIP FIRE DEPARTMENT RESPIRATORTY PROTECTION PROGRAM SALEM TOWNSHIP FIRE DEPARTMENT RESPIRATORTY PROTECTION PROGRAM PURPOSE In accordance with Michigan s Occupational Health Standards, Part 451, Respiratory Protection requires that a written Respiratory

More information

Brown County EZ Explanation for Respiratory Protection

Brown County EZ Explanation for Respiratory Protection Brown County EZ Explanation for Respiratory Protection 1910.134 Memorandum of Understanding Background Respiratory protection is of primary importance since inhalation is one of the major routes of exposure

More information

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP 7218 (NINETEENTH REVISION)

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP 7218 (NINETEENTH REVISION) East Building, PHH-30 U.S. Department 1200 New Jersey Avenue S.E. of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety Administration DOT-SP 7218 (NINETEENTH REVISION) EXPIRATION

More information

RESPIRATORY PROTECTION PROGRAM

RESPIRATORY PROTECTION PROGRAM RESPIRATORY PROTECTION PROGRAM Compliant to 29 CFR 1910.134 NEW MEXICO STATE UNIVERSITY Las Cruces, New Mexico Environmental, Health & Safety (EH&S) 505-646-3327 http://safety.nmsu.edu NMSU Respiratory

More information

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C EXPIRATION DATE: June 30, 2015

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C EXPIRATION DATE: June 30, 2015 November 14, 2014 East Building, PHH-30 U.S. Department 1200 New Jersey Avenue S.E. of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety Administration DOT-SP 16219 EXPIRATION

More information

DOT-SP 8391 (FIFTHTEENTH REVISION) EXPIRATION DATE: (FOR RENEWAL, SEE 49 CFR )

DOT-SP 8391 (FIFTHTEENTH REVISION) EXPIRATION DATE: (FOR RENEWAL, SEE 49 CFR ) U.S. Department East Building, PHH 30 of Transportation 1200 New Jersey Avenue, Southeast Washington, Pipeline and Hazardous Materials Safety Administration D.C. 20590 DOT-SP 8391 (FIFTHTEENTH REVISION)

More information

IMPORTANT SAFETY NOTICE

IMPORTANT SAFETY NOTICE February 15, 2010 IMPORTANT SAFETY NOTICE To: All Users of Survivair Panther and Cougar Self-Contained Breathing Apparatus (SCBA) Equipped with the Survivair or Sperian COMPASS Personal Alert Safety System

More information

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (ELEVENTH REVISION)

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (ELEVENTH REVISION) East Building, PHH-30 U.S. Department 1200 New Jersey Avenue S.E. of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety Administration DOT-SP 11808 (ELEVENTH REVISION) EXPIRATION

More information

ABSTRACT PLANT FILES SHOULD BE REVIEWED PERIODICALLY TO ASSURE COMPLIANCE. IF A PROBLEM EXISTS, PLEASE NOTIFY THE TACA SAFETY COMMITTEE.

ABSTRACT PLANT FILES SHOULD BE REVIEWED PERIODICALLY TO ASSURE COMPLIANCE. IF A PROBLEM EXISTS, PLEASE NOTIFY THE TACA SAFETY COMMITTEE. ABSTRACT THE FOLLOWING IS A SUMMARY OF THE LEGAL REQUIREMENTS (PER MSHA REGULATIONS) FOR POSTING AND DOCUMENTATION. THESE ARE THE MINIMUM REQUIREMENTS AT EACH PLANT, AND DO NOT INCLUDE ALL OF THE IN-HOUSE

More information

Grayslake Fire Protection District Request for Self-Contained Breathing Apparatus (SCBA) Bid

Grayslake Fire Protection District Request for Self-Contained Breathing Apparatus (SCBA) Bid Grayslake Fire Protection District Request for Self-Contained Breathing Apparatus (SCBA) Bid The Grayslake Fire Protection District invites interested and qualified parties to submit a bid for a Self-Contained

More information

Phalanx Alpha Phalanx Beta and Ultra Elite

Phalanx Alpha Phalanx Beta and Ultra Elite Phalanx Alpha Phalanx Beta and Ultra Elite riot control agent gas masks instructions parts list NIOSH approved for respiratory protection in atmospheres containing CN and CS and particulates under the

More information

CHIEF S FILE CABINET

CHIEF S FILE CABINET Closing the Gap Concerns over firefighter safety are no longer casual conversations. Increasingly, the emphasis on firefighter safety is moving from an afterthought to the forefront of everything from

More information

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2/05 GENERAL

More information

NIOSH Task Number 18388

NIOSH Task Number 18388 National Personal Protective Technology Laboratory Technology Evaluation Branch Certified Product Investigation Program Report of Self-Contained Breathing Apparatus Second Stage Regulators Submitted by

More information

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL www.modsafe.com SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device.

More information

SCOTT RIT-PAK III Portable air supply

SCOTT RIT-PAK III Portable air supply SCOTT RIT-PAK III Portable air supply Operating and Maintenance instructions For use with a SCOTT air cylinder to supply breathing air to COMPATIBLE SCOTT PRODUCTS This instruction sheet describes the

More information

OPERATION AND MAINTENANCE INSTRUCTIONS

OPERATION AND MAINTENANCE INSTRUCTIONS OPERATION AND MAINTENANCE INSTRUCTIONS SCOTT ELSA EMERGENCY LIFE SUPPORT APPARATUS ELSA 5 / ELSA 5HF / ELSA 10 / ELSA 15 IMPROPER USE OF THIS RESPIRATOR MAY RESULT IN SERIOUS INJURY OR DEATH. IMPROPER

More information

OSHA: GUIDELINES FOR EMERGENCY PREPAREDNESS AND RESPONSE

OSHA: GUIDELINES FOR EMERGENCY PREPAREDNESS AND RESPONSE OSHA: GUIDELINES FOR EMERGENCY PREPAREDNESS AND RESPONSE 1.0 INTRODUCTION The importance of an effective workplace safety and health program cannot be overemphasized. There are many benefits from such

More information

JORDAIR/BAUER Service Manual

JORDAIR/BAUER Service Manual JORDAIR/BAUER Service Manual Breathing Air Compressor Maintenance Log Doc. ServiceManual Page - 1 SAFETY RELEASE-2016 The following document is prepared to ensure safety of operators and service technicians.

More information

PURPOSE OF THE POLICY

PURPOSE OF THE POLICY Title: Safe Storage, Handling, Use and Disposal Procedures of Compressed Gas Cylinders Effective Date: November 2005 Revision Date: March 1, 2017 Issuing Authority: Responsible Officer: VP, Capital Projects

More information

SOUTH LYON FIRE DEPARTMENT Manual of Procedures 300

SOUTH LYON FIRE DEPARTMENT Manual of Procedures 300 RESPIRATORY PROTECTION PROGRAM Issued Date: March 23, 2011 Revised: March 25, 2016 Approved: Chief Mike Kennedy I. SCOPE General Industry standard 1910.134 of the Michigan Occupational Health Standards

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 1716:2003 (Incorporating Amendment No. 1) AS/NZS 1716:2003 Australian/New Zealand Standard Respiratory protective devices AS/NZS 1716:2003 This Joint Australian/New Zealand Standard was prepared

More information

RECERTIFICATION GUIDELINES FOR HIGH PRESSURE CYLINDERS TD 30/18/E

RECERTIFICATION GUIDELINES FOR HIGH PRESSURE CYLINDERS TD 30/18/E RECERTIFICATION GUIDELINES FOR HIGH PRESSURE CYLINDERS MIDDLE EAST GASES ASSOCIATION (MEGA) Dubai World Trade Centre, Sheikh Rashid Tower, Office No. ESO 20,7 th Floor, P.O. Box 9204 Dubai, UAE. Tel:+971

More information

400 Seventh Street, S.W. of Transportation Washington, D.C EXPIRATION DATE: February 28, 2010

400 Seventh Street, S.W. of Transportation Washington, D.C EXPIRATION DATE: February 28, 2010 U.S. Department 400 Seventh Street, S.W. of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety Administration DOT-SP 10945 (EIGHTEENTH REVISION) EXPIRATION DATE: February 28,

More information

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (EIGHTEENTH REVISION)

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (EIGHTEENTH REVISION) East Building, PHH-30 U.S. Department 1200 New Jersey Avenue S.E. of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety Administration DOT-SP 11194 (EIGHTEENTH REVISION) EXPIRATION

More information

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL Product Manual MST Portable Air Filtration System SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the

More information

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (FOURTH REVISION)

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (FOURTH REVISION) East Building, PHH-30 U.S. Department 1200 New Jersey Avenue S.E. of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety Administration DOT-SP 15260 (FOURTH REVISION) EXPIRATION

More information

EXPIRATION DATE: June 30, 2011

EXPIRATION DATE: June 30, 2011 East Building, PHH- U.S. Department of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety Administration DOT-SP 11194 (FOURTEENTH REVISION) 1200 New Jersey Avenue S.E. EXPIRATION

More information

RUPTURE HAZARD OF PRESSURE VESSELS

RUPTURE HAZARD OF PRESSURE VESSELS United States Office of Solid Waste EPA 550-F-97-002a Environmental Protection and Emergency Response Agency (5104) RUPTURE HAZARD OF PRESSURE VESSELS The Environmental Protection Agency (EPA) is issuing

More information

Walking-Working Surfaces and Personal Protective Equipment (Fall Protection. Systems) for General Industry; Approval of Collections of Information

Walking-Working Surfaces and Personal Protective Equipment (Fall Protection. Systems) for General Industry; Approval of Collections of Information This document is scheduled to be published in the Federal Register on 07/06/2017 and available online at https://federalregister.gov/d/2017-14122, and on FDsys.gov DEPARTMENT OF LABOR Occupational Safety

More information

Management Plan for Compressed Gas

Management Plan for Compressed Gas IEA, INC. N E W P R A G U E A R E A S C H O O L S I S D # 7 2 1 A Service-Disabled Veteran-Owned Small Business Contact Us: BROOKLYN PARK OFFICE 9201 W. BROADWAY, #600 BROOKLYN PARK, MN 55445 763-315-7900

More information

Minimum test pressure (psig) 2. Requalification period (years) DOT psig 5. non-corrosive service ( see

Minimum test pressure (psig) 2. Requalification period (years) DOT psig 5. non-corrosive service ( see 180.209 Requirements for requalification of specification cylinders. (a) Periodic qualification of cylinders. (1) Each specification cylinder that becomes due for periodic requalification, as specified

More information

Bradford Fire Department. Seeks Bids for the Purchase of Self Contained Breathing Apparatus and Related Equipment GENERAL SPECIFICATIONS WARRANTY

Bradford Fire Department. Seeks Bids for the Purchase of Self Contained Breathing Apparatus and Related Equipment GENERAL SPECIFICATIONS WARRANTY Bradford Fire Department Seeks Bids for the Purchase of Self Contained Breathing Apparatus and Related Equipment The Bradford Fire Department seeks Bids to purchase 17 Air-Pak Self Contained Breathing

More information

EXPIRATION DATE: September 30, 2013

EXPIRATION DATE: September 30, 2013 U.S. Department East Building, PHH 30 of Transportation 1200 New Jersey Avenue, Southeast Pipeline and Hazardous Materials Safety Administration DOT-SP 10945 (TWENTYFOURTH REVISION) Washington, D.C. 20590

More information

An Urgent Bulletin from CSA Group

An Urgent Bulletin from CSA Group An Urgent Bulletin from CSA Group Gas Products No. 335 (Supersedes Notice Gas Products No. 270, Ref No: N12-055) Effective Date: October 1, 2015 Date: July 21, 2014 Apply Before February 2, 2015 Announcing:

More information

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451. Calvin College Respiratory Protection Program Prepared by: Date: Heather Chapman 10/7/10 Approved by: Cabinet Revision 2 Date: 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory

More information

Article 203 Self-Contained Breathing Apparatus (SCBA)

Article 203 Self-Contained Breathing Apparatus (SCBA) 1 of 5 Article 203 Self-Contained Breathing Apparatus (SCBA) Section 203.1: Purpose The purpose is to establish guidelines to indicate the proper operation, use, training, and maintenance of self-contained

More information

Decant Filling of Gas Cylinders

Decant Filling of Gas Cylinders Safety Advice No. 18 Document No. 142-018 (Version 06) Decant Filling of Gas Cylinders ANZIGA ANZIGA is the peak industry group for the manufacture and distribution of gases in Australia and New Zealand.

More information

ORDER: APPENDIX: 3 BULLETIN TYPE: Flight Standards Handbook Bulletin for Airworthiness (HBAW)

ORDER: APPENDIX: 3 BULLETIN TYPE: Flight Standards Handbook Bulletin for Airworthiness (HBAW) ORDER: 8300.10APPENDIX: 3 BULLETIN TYPE: Flight Standards Handbook Bulletin for Airworthiness (HBAW) BULLETIN NUMBER: BULLETIN TITLE: HBAW 02-01B (Amended) Maintenance of Pressure Cylinders in Use as Aircraft

More information

Mobile Breathing Air Systems

Mobile Breathing Air Systems FAMA BUYER S GUIDE TC053 Prepared by the FAMA Body Subcommittee This guide does not endorse any manufacturer or product Page 1 of 14 Contents Introduction... 3 Overview... 4 Mobile Breathing Air System

More information

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 11 Specifications and Overview Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 11 Specifications and Overview Revised Engine Module Page 1 of 11 The City of Escondido Fire Department has developed and implemented a comprehensive respiratory program to ensure compliance with Local, State, and Federal laws concerning several

More information

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL 1 SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2 GENERAL

More information

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program. Safety & Health Program 10627 Midwest Industrial Boulevard, St. Louis, MO Phone: 314-785-6425 Fax: 314-785-6426 Compressed Gas Plan Purpose It is the policy of EMA to permit only trained and authorized

More information

National Personal Protective Technology Laboratory

National Personal Protective Technology Laboratory National Personal Protective Technology Laboratory Robert Stein CV&SDB/NPPTL/NIOSH Respiratory Protection Let s Clear the Air Quality Partnerships Enhance Worker Safety and Health DISCLAIMER: The findings

More information

RESPIRATORY PROTECTION PROCEDURE

RESPIRATORY PROTECTION PROCEDURE RESPIRATORY PROTECTION PROCEDURE 1. PURPOSE The purpose of this procedure is to protect the health and safety of University faculty and staff who work in areas that may have irritating or hazardous atmospheres.

More information

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06)

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06) Texas Department of Insurance Respiratory Protection Provided by Workers Health & Safety HS01-027B (1-06) Contents Introduction... 3 Definitions... 3 Approved Respirators... 3-4 New Respirator Selection

More information

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING Leader s Guide 2007 ERI Safety Videos THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING This easy-to-use Leader s Guide is provided to assist

More information

TABLE OF CONTENTS PART 11 - FIREFIGHTING

TABLE OF CONTENTS PART 11 - FIREFIGHTING TABLE OF CONTENTS PART 11 - FIREFIGHTING Page DEFINITIONS...11-1 APPLICATION...11-1 GENERAL REQUIREMENTS...11-2 PERSONAL PROTECTIVE CLOTHING AND EQUIPMENT FOR FIREFIGHTERS...11-2 SELF-CONTAINED BREATHING

More information

BASIC REQUIREMENTS FOR FIBER REINFORCED PLASTIC (FRP) TYPE 3FC COMPOSITE CYLINDERS

BASIC REQUIREMENTS FOR FIBER REINFORCED PLASTIC (FRP) TYPE 3FC COMPOSITE CYLINDERS 1 DOT FRP - 1 STANDARD DATE: Original; July 1, 1981 Revision 1; March 15, 1982 Revision 2; February 15, 1987 BASIC REQUIREMENTS FOR FIBER REINFORCED PLASTIC (FRP) TYPE 3FC COMPOSITE CYLINDERS 178.AA Fiber

More information

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY Page 1 of 9 ISSUED: 5/00 REVISED: 08/06 Introduction Purpose: In accordance with applicable regulations and Temple University, this policy was developed to minimize exposure to Ethylene Oxide. Applicability

More information

Midwest Consortium 8HR Modular Exam Inspect/Don/Doff

Midwest Consortium 8HR Modular Exam Inspect/Don/Doff 8HR Modular Exam Inspect/Don/Doff 1. Important reasons to inspect respirators include: A. All of the following B. Make sure the elastic parts are still stretchy C. Valves have not been removed or damaged

More information

In addition to the responsibility for managing the elements of the respiratory protection program, he/she will be responsible for:

In addition to the responsibility for managing the elements of the respiratory protection program, he/she will be responsible for: EBBE (1 of 7) EBBE RESPIRATORY PROTECTION POLICY The Muskogee School District is acknowledged as the employer, and as outlined under current Federal regulations, is assigned the responsibility to provide

More information

City of Minot Specifications SCBA

City of Minot Specifications SCBA January 2018 City of Minot Specifications SCBA The unit described under these specifications shall be the manufacturer s latest SCBA and meet the following minimum specifications. Any deviations from the

More information

LOCKOUT/TAGOUT PROGRAM

LOCKOUT/TAGOUT PROGRAM LOCKOUT/TAGOUT PROGRAM HOW CLIMATE ENGINEERS INC. COMPLIES WITH THELO/TO STANDARD It is the intent of Climate Engineers Inc. to comply with OSHA s Control of Hazardous Energy Standard (1910.147). The following

More information

HEALTH AND SAFETY MANUAL

HEALTH AND SAFETY MANUAL HEALTH AND SAFETY MANUAL Title: Hydrogen Sulfide (H 2 S) Safety Approved by: Greg Savoy Rev. 4/1/08 1 Purpose/Scope: The purpose of this program is to establish minimum requirements for site specific H

More information

COMPANY MEMBERS: All privates, engineers, lieutenants, and captains who are assigned to fire and/or rescue companies.

COMPANY MEMBERS: All privates, engineers, lieutenants, and captains who are assigned to fire and/or rescue companies. DECATUR TOWNSHIP FIRE DEPARTMENT GENERAL ORDER TITLE: MANDATORY USE OF SCBA NUMBER: 9.01 EFFECTIVE: May 1, 2016 THIS ORDER SUPERSEDES ALL PREVIOUS GENERAL ORDERS, POLICIES, RULES, S.O.G S & S.O.P S UPDATED:

More information

PORTABLES, WHEELED UNITS, AND PRE-ENGINEERED SYSTEMS Hydrostatic Test Instructions

PORTABLES, WHEELED UNITS, AND PRE-ENGINEERED SYSTEMS Hydrostatic Test Instructions Hydrostatic Test Instructions PORTABLES, WHEELED UNITS, AND PRE-ENGINEERED SYSTEMS Hydrostatic Test Instructions This manual is intended to provide persons having a practical knowledge of testing procedures

More information

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 1/00 2 GENERAL

More information

Northern Kentucky University Issue Date: 11/02/2018 Revised Date: Title: PERSONAL PROTECTIVE EQUIPMENT PROCEDURE OBJECTIVE AND PURPOSE

Northern Kentucky University Issue Date: 11/02/2018 Revised Date: Title: PERSONAL PROTECTIVE EQUIPMENT PROCEDURE OBJECTIVE AND PURPOSE Northern Kentucky University Issue Date: 11/02/2018 Revised Date: Policy Link: Occupational Safety Policy Title: PERSONAL PROTECTIVE EQUIPMENT PROCEDURE OBJECTIVE AND PURPOSE The objective of this procedure

More information

Westbrook Fire & Rescue Department Standard Operating Procedure

Westbrook Fire & Rescue Department Standard Operating Procedure 2017-103 Respiratory Protection Program Westbrook Fire & Rescue Department Standard Operating Procedure Section: Administrative TOPIC: Respiratory Protection Program NUMBER: 2017-103 ISSUE DATE: December

More information

West Clinton Fire District

West Clinton Fire District 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 West Clinton Fire District Best Practice Respiratory Protection Program Best

More information

PDY TON HYDRAULIC CRIMPING TOOL WARNING

PDY TON HYDRAULIC CRIMPING TOOL WARNING OPERATORS ORS GUIDE PDY-1220 12 TON HYDRAULIC CRIMPING TOOL All information found in this guide must be read and understood before use or testing of this tool. Failure to read and understand these warnings

More information

PPE Refresher Using your SCBA

PPE Refresher Using your SCBA PPE Refresher Using your SCBA Time Requirement: 2-3 hours total (depending on number of participants) Number of Instructors: Minimum of 2 Materials Student materials (participant guide, worksheets) Whiteboard,

More information

[Reserved] Packagings ICC 3 1 3AA 3AL 3AX 3A480X 3AAX

[Reserved] Packagings ICC 3 1 3AA 3AL 3AX 3A480X 3AAX 173.300 [Reserved] 173.301 General requirements for shipment of compressed gases and other hazardous materials in cylinders, UN pressure receptacles and spherical pressure vessels. (a) General qualifications

More information

USFA-TR-088 / November 2001

USFA-TR-088 / November 2001 U.S. Fire Administration/Technical Report Series Special Report: Prevention of Self-Contained Breathing Apparatus Failures USFA-TR-088 / November 2001 U.S. Fire Administration Fire Investigations Program

More information

CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH PROCEDURE

CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH PROCEDURE CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH PROCEDURE 1. INTRODUCTION The University uses substances hazardous to health in many of its operations, and accepts that it has a duty of care to reduce exposure

More information

1 Great Western Painting Inert Space Entry

1 Great Western Painting Inert Space Entry Great Western Painting 29 CFR 1910.1046, Permit-Required Confined Spaces INERT SPACE ENTRY Per 29 CFR 1926.21(b)(6)(i), Safety Training and Education, all employees required to enter into confined or enclosed

More information

National Personal Protective Technology Laboratory

National Personal Protective Technology Laboratory National Personal Protective Technology Laboratory Homeland Security Collaboration, Innovation and Standardization Richard Metzler October 1, 2003 Our mission... To prevent work-related illness and injury

More information

RESPIRATORY PROTECTION PROGRAM

RESPIRATORY PROTECTION PROGRAM A P P E N D I X 14 RESPIRATORY PROTECTION PROGRAM AP14.1. Purpose. AP14.2. Policy. To establish a written Respiratory Protection Program for CBP. The purpose of an effective respirator program is to provide

More information

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (NINTH REVISION)

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (NINTH REVISION) East Building, PHH-30 U.S. Department 1200 New Jersey Avenue S.E. of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety Administration DOT-SP 14576 (NINTH REVISION) EXPIRATION

More information

CONFINED SPACE ENTRY PROGRAM FOR GOUCHER COLLEGE

CONFINED SPACE ENTRY PROGRAM FOR GOUCHER COLLEGE I. INTRODUCTION CONFINED SPACE ENTRY PROGRAM FOR GOUCHER COLLEGE The Goucher College campus has confined spaces that, due to various chemical and physical properties, may cause death or serious injury

More information

BP U.S. Pipelines & Logistics (USPL) Safety Manual Page 1 of 8

BP U.S. Pipelines & Logistics (USPL) Safety Manual Page 1 of 8 Safety Manual Page 1 of 8 1. Purpose The purpose of this policy is to protect USPL employees and contractors from overexposure to benzene. 2. Scope This policy applies to all USPL employees and contractors

More information

RESPIRATORY PROTECTION PROGRAM OSHA Respiratory Protection

RESPIRATORY PROTECTION PROGRAM OSHA Respiratory Protection RESPIRATORY PROTECTION PROGRAM 1910.134 OSHA Respiratory Protection Table of Contents Introduction... 3 Scope... 3 Definitions... 3 Responsibilities... 5 Voluntary Use... 6 Use Requirements... 6 Program

More information

Shipyard welder ignites hydraulic fluid and is fatally burned

Shipyard welder ignites hydraulic fluid and is fatally burned OR 2003-22-1 Shipyard welder ignites hydraulic fluid and is fatally burned Summary A 48-year-old shipyard welder was injured and died 62 days later from burns she sustained when her wire fed welder ignited

More information