Title: Agreement between pedometer and accelerometer in measuring physical activity in overweight and obese pregnant women

Size: px
Start display at page:

Download "Title: Agreement between pedometer and accelerometer in measuring physical activity in overweight and obese pregnant women"

Transcription

1 Author's response to reviews Title: Agreement between pedometer and accelerometer in measuring physical activity in overweight and obese pregnant women Authors: Tarja I Kinnunen (tarja.kinnunen@ncl.ac.uk) Peter WG Tennant (peter.tennant@ncl.ac.uk) Catherine McParlin (catherine.mcparlin@ncl.ac.uk) Lucilla Poston (lucilla.poston@kcl.ac.uk) Stephen C Robson (s.c.robson@ncl.ac.uk) Ruth Bell (ruth.bell@ncl.ac.uk) Version: 2 Date: 6 May 2011 Author's response to reviews: see over

2 1 Author Response Letter Manuscript Reference: Authors: Tarja I Kinnunen, Peter WG Tennant, Catherine McParlin, Lucilla Poston, Stephen C Robson and Ruth Bell Title: Agreement between pedometer and accelerometer in measuring physical activity in overweight and obese pregnant women Dear Professor Gabriella Anderson, Thank you for considering our paper and for providing us with the opportunity for resubmission. The following letter details our response to each of the referees comments. The original comments are included in italics. Reviewer 1, Stephanie Prince: Overall impressions: This was a very well, clear and concise paper on the measurement discrepancies between pedometers and accelerometers in overweight pregnant women. The methods employed were appropriate and the conclusions justified. I would recommend this for publication. Background Discretionary revisions: 1. This section was thought to be well written. The description of discrepancy between self-report and direct measures is well founded (perhaps the authors may wish to highlight this by providing an example of the level of agreement between a self-report and direct measurement of PA in a pregnant population as per their references # 5-7). We have included a brief description of two recent studies comparing accelerometers and pedometers in pregnant women (Connolly et al. 2010, Harrison et al. 2011). As these are the most pertinent studies to the aims of our paper we have not extended the Background further. 2. Third paragraph: I would also bring to the authors attention that some recent work has been done in the field looking at validation of pedometers against accelerometers in pregnant women. Please see the following reference: Connolly CP, Coe DP, Kendrick JM, Bassett DRJ, Thompson DL. Accuracy of Physical Activity Monitors in Pregnant Women. Medicine & Science in Sports & Exercise 2010;Publish Ahead of Print. The devices were validated using treadmill walking, rather than free-living conditions used in the present study, but it would be good to reference the similarities/differences between the two studies. This study was not available at the time of submission, but we have updated the manuscript to include this paper. Methods The study participant, data collection, and categorization sections were clearly written. Minor Essential Revisions: These revisions refer to the statistical analyses section. 1. Can the authors comment to why they did not use means, standard deviations (SDs) and range rather than median and inter-quartile ranges? The median represents the middle point of the data,

3 2 but it is unclear as to how this provides better information regarding the spread and distribution of the step counts across the women. The authors would be urged to include means and SDs. In our data, most of the physical activity variables were not normally distributed and therefore it was not appropriate to report means and SDs. Consequently, we used non-parametric tests and reported medians and IQRs for all variables. It might be confusing for the readers if we reported both medians and means as the statistical analyses were made for the medians only. Results Minor Essential Revisions: The authors make use of the Bland-Altman method to examine % agreement between the two measures for overall step counts. Could they provide the mean differences between the two measurements rather than just the means and limits of agreement and include this in Figure 3? This information can be found in the text on page 11 in Results: "There was no significant difference between the overall step counts recorded by the pedometer compared to the accelerometer (medians 5961 vs steps/day, p=0.37)." Discussion This section was very well written. There are no suggestions for improvement other than the discussion of the reference mentioned above for the introduction. Reviewer 2, Tiago Barreira: Major Compulsory Revisions 1. The main problem with this manuscript is the lack of clarity in the conclusion. The readers don t come out with a precise answer about the devices; the article raises more questions than gives answers. It is not clear if one device is better than the other or even if the step counts from the devices can be used interchangeably or not. We have now clarified our conclusions in the abstract. This study does not answer the question which of the monitors is more accurate, but it shows that the monitors do not agree well with each other and the step counts cannot be used interchangeably. 2. There is a need to update the references, which will lead to re-writing a large portion of the manuscript. There is a study examining the validity of pedometers and accelerometer in pregnant women. See provided reference. We have updated the references and modified the introduction and discussion to include studies that were published after our article was submitted to BMC Public Health. This most notably allows us to include two very recent studies comparing accelerometers and pedometers in pregnant women (Harrison et al. 2011, Connolly et al. 2010). 3. It is very important to make a clear distinction between some of the accelerometers references. Most of the references refer to the Actigraph 7164 and in this study the accelerometer used was the GT1M and they are not similar in their measurement. When describing the Actigraph accelerometers used in different studies (references 18, 19, 20, 26, 38), we now specify in Methods and Discussion whether they used the 7164 model or some other

4 model. We have also added a reference to a recent study by Kozey et al. (2010), which suggested that the 7164 model detected more steps but less counts than the GT1M model (see the second paragraph in Discussion). However this difference did not affect activity intensity classifications and the authors concluded that the monitors should be comparable when estimating habitual activity levels. 4. There are a large number of studies that show the superiority of piezoelectric pedometers over the Yamax (a spring lever pedometer). Even the references used to make the point that the Yamax is a superior device are questionable to support this statement. We have now included the following sentence and reference in the Discussion when describing the accuracy of Yamax Digi-Walker pedometer: On the other hand, another study showed that tilt angle reduces the accuracy of spring-levered pedometers (such as Yamax Digi-Walker) in overweight and obese adults (Crouter et al. 2005). 5. It is also known that the spring lever pedometer have problems with tilt angle caused by large waist circumference or high BMI, which could be a problem in this population. The authors state that high BMI is not a problem, which is not true. We have discussed the possible effect of tilt angle on the results in the Discussion as follows: The accuracy of the latest Actigraph accelerometer model (GT3X) and Yamax Digiwalker SW-200 was recently investigated in 30 pregnant women (Connolly et al. 2010). Both monitors underestimated the number of steps especially at slow walking speeds, but positioning the monitors at a tilt angle did not correlate with the percentage of actual steps detected by either monitor. In contrast, Crouter et al. (2005) suggested that the tilt angle reduced the accuracy of spring-levered pedometers in overweight or obese adults. The tilt angle may also reduce the accuracy of accelerometers in assessing vertical movement, which may happen more often among overweight and obese than normal weight people [17]. The tilt angle was not directly measured in the present study. However, BMI and gestational age did not significantly modify the results of the Bland-Altman plot suggesting that the potential effect of the tilt angle on the results may have been the same regardless of BMI or gestational age. 6. The recommendation of steps/day based on 10 min of MVPA is not accurate; 10 min of MVPA would require at least 1000 steps or more. There are a large number of references making the relationship between MVPA and 100 steps/min. Revise references and recommendation. We agree with the reviewer that 10 min of MVPA would give at least 1000 steps, not 500 steps. Our purpose was to say that ±500 steps/day corresponds to a range of 1000 steps/day, which obviously was not clear for the readers. We have clarified the sentence in the manuscript as follows: We propose that they should be no larger than ±500 steps/day (i.e. a range of 1000 steps/day), which is likely to correspond to a maximum of 10 min difference in the duration of MVPA, such as brisk walking [32], and may therefore be of clinical and public health importance. 7. The reported problem with lack of accuracy of pedometers at slow walking speeds is also a problem with accelerometers. See reference provided. We have revised the text in Discussion as follows: This may also be the case with some accelerometers, although the GT1M model used in our study has been shown to have lower intermonitor variability and lower sensitivity for light intensity activity than the preceding 7164 model (Rothney et al. 2008, Kozey et al. 2010). On the other 3

5 4 hand, the previous CSA model has also been reported to erroneously detect slightly more nonsteps e.g. when travelling by a motor vehicle [38]. 8. The information about epoch length does not make sense. The cut points used in this study were developed for 60 sec epochs. Physical activity cannot be classified using those cut points and shorter epochs unless the authors provide references to justify this approach. We have now used 60s epoch length in all analyses and reported those results. The number of women with at least 3 valid days and pedometer step counts is now 58 instead of 62. The results were essentially the same as before, when comparing pedometer and accelerometer data. The absolute durations of activity at each intensity level have changed slightly. The results are now also comparable with the results of the study by Harrison et al., as they also used 60s epoch length. We have removed the discussion on epoch length as it is no longer relevant. 9. There are a few participants that had very low numbers for step counts measured by the pedometer and high difference compared to the accelerometer. The authors try to explain this by attributing to different wear time of the devices, but this is probably not the case. It doesn t make sense that the person would wear one device and not the other. It appears that the pedometers were in a position that did not work well or it was just equipment malfunction. Those are definitely outliers and the deletion of those points should be explored. We can only speculate on the reasons for very low pedometer step counts. As the reviewer suggested, it is possible that some of the pedometers failed to detect steps accurately (possibly because of tilt angle). However, we did not find any evidence of equipment malfunction, e.g. the same monitors worked well when used in subsequent women. Furthermore, it is not possible to exclude the possibility that the devices were not worn for the same time. We have carefully considered the possibility of excluding some outliers from the analyses and came to the conclusion that it would be better not to do so. Firstly, this is because any outlier definition would be very arbitrary. For example, for 3 of the 4 women with the lowest pedometer step counts (from 224 to 402 steps/day) the difference between pedometer and accelerometer step counts varied from 1158 to 2215 steps/day only while for the fourth the difference was 5612 step/day. On the other hand, there were several women with higher pedometer step counts for whom the difference between the monitors was several thousand steps/day. Should these women also be excluded? More importantly, this study is about measuring agreement in the real world. Excluding potentially valid individuals because of low (but not impossible counts) therefore risks biasing the results and altering the conclusions. Finally, there was no evidence that the parametric assumptions of the regression-based Bland- Altman method were violated, suggesting there were no 'outliers' for the most important variable on test i.e. the level of agreement. 10. The authors make it clear that the difference between step counts measured by the devices were in opposite direction in the low activity participants and high activity participants but they do not do a good job explaining why those differences happened. Why did the pedometer count more steps at the high end? Why the pedometer counted fewer steps in the low end? This is a good question. Unfortunately we are not able to provide any more exhaustive answer to it than already presented in the Discussion. 11. The conclusion in the abstract is not supported by the results. It is not clear why accelerometers would be a better choice than pedometers.

6 5 We have revised the abstract conclusion: Pedometer and accelerometer steps cannot be used interchangeably in overweight and obese pregnant women. 12. The Actigraph is not the only accelerometer that has outputs that are highly correlated to DLW. See reference bellow. As previously mentioned the Actigraph used in reference 26 is not the same used in this study. We have revised two sentences in the Discussion and incorporated the reviewer s comment as follows: Although the previous version of the Actigraph accelerometer was the only commercially available accelerometer [26] that correlated reasonably with doubly labelled water, most validation studies have been conducted in controlled environments. Validity is lower when applied to freeliving settings [17]. Two armband accelerometers have recently been shown to be highly correlated with doubly labeled water in free-living conditions (Johanssen et al. 2010). 13. Why were the 60 min interval and the 500 min total time chosen as standards? Any references for it? To our knowledge, there is no consensus for defining a valid day, but approximately 10 hours is often used (Mâsse 2005, Corder et al. 2007). The same applies to the length of the period with no counts that should be excluded. Minor Essential Revisions Introduction 1. The information about quality trials is irrelevant to the article, should delete. We feel the sentence However, the available evidence is limited and larger and better quality trials are needed (at the beginning of the Background) is indeed relevant for this article: We believe a number of researchers will be interested in whether simpler and cheaper pedometers provide comparable results to accelerometers and can therefore be used in future physical activity trials. We would therefore prefer to keep this sentence in the text. Methods 14. Make clear that the cut points were created for a different version of the Actigraph. We have added the following sentence to the Methods when describing accelerometer data collection. These cut points were originally developed for CSA Model 7164 accelerometer. Results 1. Provide the whole information about the Mann-Whitney U test and not just the p-value. We now report medians (for age) or percentages (for smoking and education) for all background variables, where there were statistically significant differences between the included and the excluded women. Discussion 1. The authors use mean across the discussion. Shouldn t it be median. If that is not true make clear why the change happened.

7 6 We agree with the reviewer that we should use medians when referring to our own results. We found only one instance where we had quoted mean instead of median and we have revised that (the last paragraph where reporting our conclusions). When discussing the results of Bland-Altman plots, the situation is different as we used the mean of accelerometer and pedometer steps on x- axis (Figure 2). Use of the mean is hence appropriate when discussing these results. When referring to results of other studies, we refer to whatever measure of central tendency was reported in the original paper. 2. The information about the Actigraph counting steps refers to a previous version of the accelerometer. Any information on the version used in this study? We have added the following sentence in the Discussion: This may also be the case with some accelerometers, although the GT1M model used in our study has been shown to have lower intermonitor variability and lower sensitivity for light intensity activity than the preceding 7164 model (Rothney et al. 2008, Kozey et al. 2010). 3. There is no need to mention the problem with cycling. We have removed this sentence from the Discussion. Yours Sincerely, Tarja Kinnunen, Peter Tennant, Catherine McParlin, Lucilla Poston, Stephen Robson and Ruth Bell References: Connolly CP, Coe DP, Kendrick JM, Bassett DRJ, Thompson DL. Accuracy of Physical Activity Monitors in Pregnant Women. Medicine & Science in Sports & Exercise 2010; published ahead of print Corder K, Brage S, Ekelund U. Accelerometers and pedometers: methodology and clinical application. Curr Opin Clin Nutr Metab Care 2007:10: Crouter SE, Schneider PL, Bassett DR, Jr. Spring-Levered versus Piezo-Electric Pedometer Accuracy in Overweight and Obese Adults. Med Sci Sports Exerc 2005;37: Harrison CL, Thompson RG, Teede HJ, Lombard CB. Measuring physical activity during pregnancy. Int J Behav Nutr Phys Act 2011,8:19. Johannsen DL, Calabro MA, Stewart J, Franke W, Rood JC, Welk GJ. Accuracy of armband monitors for measuring daily energy expenditure in healthy adults. Med Sci Sports Exerc 2010;42: Kozey SL, Staudenmayer JW, Troiano RP, Freedson PS. Comparison of the ActiGraph 7164 and the ActiGraph GT1M during Self-Paced Locomotion. Med Sci Sports Exerc 2010;42: Mâsse LC, Fuemmeler BF, Anderson B, Matthews CE, Trost SG. Catellier DJ, Treuth M. Accelerometer Data Reduction: A Comparison of Four Reduction Algorithms on Select Outcome Variables. Med Sc. Sports Exerc 2005;37:S544-S554. Rothney MP, Apker GA, Song Y, Chen KY. Comparing the performance of three generations of ActiGraph accelerometers. J Appl Physiol 2008;105:

Accurate assessment of physical activity (PA) in a

Accurate assessment of physical activity (PA) in a Comparison of the ActiGraph 7164 and the ActiGraph GT1M during Self-Paced Locomotion SARAH L. KOZEY 1, JOHN W. STAUDENMAYER 2, RICHARD P. TROIANO 3, and PATTY S. FREEDSON 1 1 Department of Kinesiology,

More information

Effects of Age and Body Mass Index on Accuracy of Simple Moderate Vigorous Physical Activity Monitor Under Controlled Condition

Effects of Age and Body Mass Index on Accuracy of Simple Moderate Vigorous Physical Activity Monitor Under Controlled Condition Received: May., 011 Accepted: Jul. 8, 011 Published online: Jul. 5, 011 Original Article Effects of Age and Body Mass Index on Accuracy of Simple Moderate Vigorous Physical Activity Monitor Under Controlled

More information

Convergent Validity of 3 Low Cost Motion Sensors With the ActiGraph Accelerometer

Convergent Validity of 3 Low Cost Motion Sensors With the ActiGraph Accelerometer Journal of Physical Activity and Health, 2010, 7, 662-670 2010 Human Kinetics, Inc. Convergent Validity of 3 Low Cost Motion Sensors With the ActiGraph Accelerometer James J. McClain, Teresa L. Hart, Renee

More information

Validity of Four Activity Monitors during Controlled and Free-Living Conditions

Validity of Four Activity Monitors during Controlled and Free-Living Conditions Illinois State University ISU ReD: Research and edata Theses and Dissertations 8-27-2013 Validity of Four Activity Monitors during Controlled and Free-Living Conditions Joey Lee Illinois State University,

More information

Evaluation of a commercially available

Evaluation of a commercially available Loughborough University Institutional Repository Evaluation of a commercially available pedometer used to promote physical activity as part of a national programme This item was submitted to Loughborough

More information

Objective Physical Activity Monitoring for Health-Related Research: A Discussion of Methods, Deployments, and Data Presentations

Objective Physical Activity Monitoring for Health-Related Research: A Discussion of Methods, Deployments, and Data Presentations Objective Physical Activity Monitoring for Health-Related Research: A Discussion of Methods, Deployments, and Data Presentations John M. Schuna Jr., PhD School of Biological and Population Health Sciences

More information

Comparisons of Accelerometer and Pedometer Determined Steps in Free Living Samples

Comparisons of Accelerometer and Pedometer Determined Steps in Free Living Samples Journal of Physical Activity and Health, 2011, 8, 390-397 2011 Human Kinetics, Inc. Comparisons of Accelerometer and Pedometer Determined Steps in Free Living Samples Timothy K. Behrens and Mary K. Dinger

More information

Convergent Validity of Pedometer and Accelerometer Estimates of Moderate-to-Vigorous Physical Activity of Youth

Convergent Validity of Pedometer and Accelerometer Estimates of Moderate-to-Vigorous Physical Activity of Youth Journal of Physical Activity and Health, 2011, 8(Suppl 2), S295 -S305 2011 Human Kinetics, Inc. Convergent Validity of Pedometer and Accelerometer Estimates of Moderate-to-Vigorous Physical Activity of

More information

Effects of Placement, Attachment, and Weight Classification on Pedometer Accuracy

Effects of Placement, Attachment, and Weight Classification on Pedometer Accuracy Brigham Young University BYU ScholarsArchive All Faculty Publications 2007-10-01 Effects of Placement, Attachment, and Weight Classification on Pedometer Accuracy Susan V. Graser William J. Vincent bill_vincent@byu.edu

More information

Presence and duration of reactivity to pedometers in adults

Presence and duration of reactivity to pedometers in adults Loughborough University Institutional Repository Presence and duration of reactivity to pedometers in adults This item was submitted to Loughborough University's Institutional Repository by the/an author.

More information

INFLUENCE OF PEDOMETER TILT ANGLE ON STEP COUNTING VALIDITY DURING CONTROLLED TREADMILL WALKING TRIALS. Melissa Dock

INFLUENCE OF PEDOMETER TILT ANGLE ON STEP COUNTING VALIDITY DURING CONTROLLED TREADMILL WALKING TRIALS. Melissa Dock INFLUENCE OF PEDOMETER TILT ANGLE ON STEP COUNTING VALIDITY DURING CONTROLLED TREADMILL WALKING TRIALS by Melissa Dock A thesis submitted in partial fulfillment of the requirements for the degree of Master

More information

The validation of Fitbit Zip physical activity monitor as a measure of free-living physical activity

The validation of Fitbit Zip physical activity monitor as a measure of free-living physical activity Tully et al. BMC Research Notes 2014, 7:952 SHORT REPORT Open Access The validation of Fitbit Zip physical activity monitor as a measure of free-living physical activity Mark A Tully 1,2*, Cairmeal McBride

More information

Accuracy of a Pedometer and an Accelerometer in Women with Obesity

Accuracy of a Pedometer and an Accelerometer in Women with Obesity The Open Obesity Journal, 2012, 4, 11-17 11 Open Access Accuracy of a Pedometer and an Accelerometer in Women with Obesity Malin Wiklund *, Åsa Cider and Monika Fagevik Olsén Department of Physiotherapy

More information

Health & Fitness Journal

Health & Fitness Journal Health & Fitness Journal of Canada Copyright 2012 The Authors. Journal Compilation Copyright 2012 Health & Fitness Program of BC Volume 5 December 30, 2012 Number 4! ORIGINAL!ARTICLE! Is!this!Bit!Fit?!Measuring!the!Quality!of!the!FitBit!StepACounter!

More information

Physical Activity monitors: Limitations to measure physical activity in the free-living environment

Physical Activity monitors: Limitations to measure physical activity in the free-living environment Physical Activity monitors: Limitations to measure physical activity in the free-living Monitores de Actividad Física: limitaciones para medir la actividad física en la vida cotidiana Yuri Feito 1 Resumen

More information

Comparison of pedometer and accelerometer measures of physical activity during preschool time on 3- to 5-year-old children

Comparison of pedometer and accelerometer measures of physical activity during preschool time on 3- to 5-year-old children 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 REGULAR ARTICLE Comparison of pedometer and accelerometer

More information

JEPonline Journal of Exercise Physiologyonline

JEPonline Journal of Exercise Physiologyonline Walking Technique and Estimated VO 2 max Values 21 JEPonline Journal of Exercise Physiologyonline Official Journal of The American Society of Exercise Physiologists (ASEP) ISSN 1097-9751 An International

More information

Medicine. Cadence Feedback With ECE PEDO to Monitor Physical Activity Intensity. A Pilot Study. Fusun Ardic, MD and Esra Göcer, MD

Medicine. Cadence Feedback With ECE PEDO to Monitor Physical Activity Intensity. A Pilot Study. Fusun Ardic, MD and Esra Göcer, MD Medicine OBSERVATIONAL STUDY Cadence Feedback With ECE PEDO to Monitor Physical Activity Intensity A Pilot Study Fusun Ardic, MD and Esra Göcer, MD Abstract: The purpose of this study was to examine the

More information

Validity of the Actical Accelerometer Step-Count Function in Children

Validity of the Actical Accelerometer Step-Count Function in Children Pediatric Exercise Science, 2011, 23, 355-365 2011 Human Kinetics, Inc. Validity of the Actical Accelerometer Step-Count Function in Children Richard R. Rosenkranz Kansas State University, University of

More information

Validation of Omron Pedometers Using MTI Accelerometers for Use with Children

Validation of Omron Pedometers Using MTI Accelerometers for Use with Children Original Research Validation of Omron Pedometers Using MTI Accelerometers for Use with Children BRADLEY P. PETERS, KATE A. HEELAN, and BRYCE ABBEY Health, Physical Education, Recreation, and Leisure Studies

More information

This study investigated the amount of physical activity that occurred during

This study investigated the amount of physical activity that occurred during Abstract This study investigated the amount of physical activity that occurred during work and total waking hours in a sample of New Zealand professional office workers. Data were collected over three

More information

Convergent Validity of a Piezoelectric Pedometer and an Omnidirectional Accelerometer for Measuring Children s Physical Activity

Convergent Validity of a Piezoelectric Pedometer and an Omnidirectional Accelerometer for Measuring Children s Physical Activity Pediatric Exercise Science, 2011, 23, 399-410 2011 Human Kinetics, Inc. Convergent Validity of a Piezoelectric Pedometer and an Omnidirectional Accelerometer for Measuring Children s Physical Activity

More information

Analysis of energy systems in Greco-Roman and freestyle wrestlers participated in 2015 and 2016 world championships

Analysis of energy systems in Greco-Roman and freestyle wrestlers participated in 2015 and 2016 world championships Analysis of energy systems in Greco-Roman and freestyle wrestlers participated in 2015 and 2016 world championships Abstract. Aim: The aim of this study was analysis of energy systems in Greco- Roman (GR)

More information

Safety Assessment of Installing Traffic Signals at High-Speed Expressway Intersections

Safety Assessment of Installing Traffic Signals at High-Speed Expressway Intersections Safety Assessment of Installing Traffic Signals at High-Speed Expressway Intersections Todd Knox Center for Transportation Research and Education Iowa State University 2901 South Loop Drive, Suite 3100

More information

Femke De Meester 1*, Delfien Van Dyck 1,2, Ilse De Bourdeaudhuij 1 and Greet Cardon 1

Femke De Meester 1*, Delfien Van Dyck 1,2, Ilse De Bourdeaudhuij 1 and Greet Cardon 1 De Meester et al. BMC Public Health 2014, 14:631 RESEARCH ARTICLE Open Access Parental perceived neighborhood attributes: associations with active transport and physical activity among 10 12 year old children

More information

Saunders et al. BMC Public Health 2014, 14:519

Saunders et al. BMC Public Health 2014, 14:519 Saunders et al. BMC Public Health 2014, 14:519 RESEARCH ARTICLE Open Access Validity of SC-StepRx pedometer-derived moderate and vigorous physical activity during treadmill walking and running in a heterogeneous

More information

Validation of an Electronic Pedometer for Measurement of Physical Activity in Children

Validation of an Electronic Pedometer for Measurement of Physical Activity in Children Pediatric Exercise Science, 1999, 11, 63-68 O 1999 Human Kinetics Publishers, Inc. Validation of an Electronic Pedometer for Measurement of Physical Activity in Children Colleen K. Kilanowski, Angela R.

More information

HSIS. Association of Selected Intersection Factors With Red-Light-Running Crashes. State Databases Used SUMMARY REPORT

HSIS. Association of Selected Intersection Factors With Red-Light-Running Crashes. State Databases Used SUMMARY REPORT HSIS HIGHWAY SAFETY INFORMATION SYSTEM The Highway Safety Information Systems (HSIS) is a multi-state safety data base that contains accident, roadway inventory, and traffic volume data for a select group

More information

Achieving 10,000 steps: A comparison of public transport users and drivers in a University setting

Achieving 10,000 steps: A comparison of public transport users and drivers in a University setting Title page Achieving 10,000 steps: A comparison of public transport users and drivers in a University setting Karen Villanueva Billie Giles-Corti Gavin McCormack School of Population Health, The University

More information

Validation of PiezoRx Pedometer Derived Sedentary Time

Validation of PiezoRx Pedometer Derived Sedentary Time Original Research Validation of PiezoRx Pedometer Derived Sedentary Time KATELYNN DONAHOE 1, DANY J. MACDONALD 1, MARK S. TREMBLAY 2, TRAVIS J. SAUNDERS 1 1 Department of Applied Human Sciences, Faculty

More information

measures Second generation accelerometers

measures Second generation accelerometers Accelerometer issues SINGLE-SITE PLACEMENT; waist placement -> PA underestimate during upper limb movement, standing, vertical activity (i.e., climbing stairs, uphill walking), pushing or pulling objects,

More information

Increasing our understanding of reactivity to pedometers in adults

Increasing our understanding of reactivity to pedometers in adults Loughborough University Institutional Repository Increasing our understanding of reactivity to pedometers in adults This item was submitted to Loughborough University's Institutional Repository by the/an

More information

Four-week pedometer-determined activity patterns in normal-weight, overweight. and obese adults

Four-week pedometer-determined activity patterns in normal-weight, overweight. and obese adults Loughborough University Institutional Repository Four-week pedometer-determined activity patterns in normal-weight, overweight and obese adults This item was submitted to Loughborough University's Institutional

More information

Reliability and validity of a physical activity questionnaire in children

Reliability and validity of a physical activity questionnaire in children International Journal of Food Sciences and Nutrition, September 2012; 63(6): 637 644 Reliability and validity of a physical activity questionnaire in children CARINE PLATAT & AMJAD JARRAR Department of

More information

Sandra Nutter, MPH James Sallis, PhD Gregory J Norman, PhD Sherry Ryan, PhD Kevin Patrick, MD, MS

Sandra Nutter, MPH James Sallis, PhD Gregory J Norman, PhD Sherry Ryan, PhD Kevin Patrick, MD, MS Objectively Measured Environmental Correlates of Adolescent Physical Activity Sandra Nutter, MPH James Sallis, PhD Gregory J Norman, PhD Sherry Ryan, PhD Kevin Patrick, MD, MS San Diego State University

More information

Measuring physical activity in youth settings: Considerations for instrument selection

Measuring physical activity in youth settings: Considerations for instrument selection Measuring physical activity in youth settings: Considerations for instrument selection By: Benjamin Hickerson Hickerson, B. (2011). Measuring physical activity in youth settings: Considerations for instrument

More information

STAT 625: 2000 Olympic Diving Exploration

STAT 625: 2000 Olympic Diving Exploration Corey S Brier, Department of Statistics, Yale University 1 STAT 625: 2000 Olympic Diving Exploration Corey S Brier Yale University Abstract This document contains a preliminary investigation of data from

More information

SUPPLEMENTARY INFORMATION

SUPPLEMENTARY INFORMATION doi:10.1038/nature17654 Contents Supplementary Text S1. Calculating Locomotor Costs Supplementary Table 1. Estimated ranging costs for humans and other hominoids Supplementary Text S2. Estimating the Costs

More information

Effect of walking speed and placement position interactions in determining the accuracy of various newer pedometers

Effect of walking speed and placement position interactions in determining the accuracy of various newer pedometers Available online at www.sciencedirect.com ScienceDirect Journal of Exercise Science & Fitness 12 (214) 31e37 Original article Effect of walking speed and placement position interactions in determining

More information

Evaluating the Influence of R3 Treatments on Fishing License Sales in Pennsylvania

Evaluating the Influence of R3 Treatments on Fishing License Sales in Pennsylvania Evaluating the Influence of R3 Treatments on Fishing License Sales in Pennsylvania Prepared for the: Pennsylvania Fish and Boat Commission Produced by: PO Box 6435 Fernandina Beach, FL 32035 Tel (904)

More information

NCSS Statistical Software

NCSS Statistical Software Chapter 256 Introduction This procedure computes summary statistics and common non-parametric, single-sample runs tests for a series of n numeric, binary, or categorical data values. For numeric data,

More information

Using Hexoskin Wearable Technology to Obtain Body Metrics During Trail Hiking

Using Hexoskin Wearable Technology to Obtain Body Metrics During Trail Hiking Technical Note Using Hexoskin Wearable Technology to Obtain Body Metrics During Trail Hiking JEFF MONTES 1, TORI M. STONE 1, JACOB W. MANNING 2, DAMON MCCUNE 1, DEBRA K. TACAD 1, JOHN C. YOUNG 1, MARK

More information

HHS Public Access Author manuscript Int J Cardiol. Author manuscript; available in PMC 2016 April 15.

HHS Public Access Author manuscript Int J Cardiol. Author manuscript; available in PMC 2016 April 15. FITBIT : AN ACCURATE AND RELIABLE DEVICE FOR WIRELESS PHYSICAL ACTIVITY TRACKING Keith M. Diaz 1, David J. Krupka 1, Melinda J Chang 1, James Peacock 1, Yao Ma 2, Jeff Goldsmith 2, Joseph E. Schwartz 1,

More information

ACCURACY OF PIEZOELECTRIC PEDOMETER AND ACCELEROMETER STEP COUNTS

ACCURACY OF PIEZOELECTRIC PEDOMETER AND ACCELEROMETER STEP COUNTS ACCURACY OF PIEZOELECTRIC PEDOMETER AND ACCELEROMETER STEP COUNTS Joana Cruz, 1,2 Dina Brooks, 3 Alda Marques 1,2 1 Lab 3R Respiratory Research and Rehabilitation Laboratory, School of Health Sciences,

More information

University of Groningen. The use of self-tracking technology for health Kooiman, Theresia Johanna Maria

University of Groningen. The use of self-tracking technology for health Kooiman, Theresia Johanna Maria University of Groningen The use of self-tracking technology for health Kooiman, Theresia Johanna Maria IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to

More information

TECHNICAL STUDY 2 with ProZone

TECHNICAL STUDY 2 with ProZone A comparative performance analysis of games played on artificial (Football Turf) and grass from the evaluation of UEFA Champions League and UEFA Cup. Introduction Following on from our initial technical

More information

Bhagwant N. Persaud* Richard A. Retting Craig Lyon* Anne T. McCartt. May *Consultant to the Insurance Institute for Highway Safety

Bhagwant N. Persaud* Richard A. Retting Craig Lyon* Anne T. McCartt. May *Consultant to the Insurance Institute for Highway Safety Review of The Impact of Red Light Cameras (Photo-Red Enforcement) on Crashes in Virginia by Nicholas J. Garber, John S. Miller, R. Elizabeth Abel, Saeed Eslambolchi, and Santhosh K. Korukonda Bhagwant

More information

INTERACTION OF STEP LENGTH AND STEP RATE DURING SPRINT RUNNING

INTERACTION OF STEP LENGTH AND STEP RATE DURING SPRINT RUNNING INTERACTION OF STEP LENGTH AND STEP RATE DURING SPRINT RUNNING Joseph P. Hunter 1, Robert N. Marshall 1,, and Peter J. McNair 3 1 Department of Sport and Exercise Science, The University of Auckland, Auckland,

More information

Activity profiles in adolescent netball: A combination of global positioning system technology and time-motion analysis

Activity profiles in adolescent netball: A combination of global positioning system technology and time-motion analysis Proceeding Asia Pacific Conference on Performance Analysis of Sport, 21-24 April 2014. Langkawi, Malaysia Activity profiles in adolescent netball: A combination of global positioning system technology

More information

Validation and Comparison of Two Ankle- Mounted and Two Waist-Mounted Electronic Pedometers

Validation and Comparison of Two Ankle- Mounted and Two Waist-Mounted Electronic Pedometers University of Tennessee, Knoxville Trace: Tennessee Research and Creative Exchange Masters Theses Graduate School 8-2004 Validation and Comparison of Two Ankle- Mounted and Two Waist-Mounted Electronic

More information

Using Accelerometry: Methods Employed in NHANES

Using Accelerometry: Methods Employed in NHANES Using Accelerometry: Methods Employed in NHANES Richard Troiano, Ph.D. David Berrigan, Ph.D. National Cancer Institute Overview NHANES Accelerometry Accelerometry Analytic Issues Decisions and data cleaning

More information

Assessment of an International Breaststroke Swimmer Using a Race Readiness Test

Assessment of an International Breaststroke Swimmer Using a Race Readiness Test International Journal of Sports Physiology and Performance, 2009, 4, 139-143 2009 Human Kinetics, Inc. Assessment of an International Breaststroke Swimmer Using a Race Readiness Test Kevin G. Thompson

More information

Clinical Study Synopsis

Clinical Study Synopsis Clinical Study Synopsis This Clinical Study Synopsis is provided for patients and healthcare professionals to increase the transparency of Bayer's clinical research. This document is not intended to replace

More information

Calculation of Trail Usage from Counter Data

Calculation of Trail Usage from Counter Data 1. Introduction 1 Calculation of Trail Usage from Counter Data 1/17/17 Stephen Martin, Ph.D. Automatic counters are used on trails to measure how many people are using the trail. A fundamental question

More information

Exploring the relationship between Heart Rate (HR) and Ventilation Rate (R) in humans.

Exploring the relationship between Heart Rate (HR) and Ventilation Rate (R) in humans. Exploring the relationship between Heart Rate (HR) and Ventilation Rate (R) in humans. The Research Question In this investigation I will be considering the following general research question: Does increased

More information

Are Active Australia physical activity questions valid for older adults? Running Head: Are questions valid?

Are Active Australia physical activity questions valid for older adults? Running Head: Are questions valid? Are Active Australia physical activity questions valid for older adults? Running Head: Are questions valid? 1 ABSTRACT Objective The Active Australia Survey (AAS) is used for physical activity (PA) surveillance

More information

Investigating the Validity of the MVPA Feature on the New Lifestyles 1000 Pedometer in Children with Visual Impairments. Killeen Pritchard.

Investigating the Validity of the MVPA Feature on the New Lifestyles 1000 Pedometer in Children with Visual Impairments. Killeen Pritchard. Investigating the Validity of the MVPA Feature on the New Lifestyles 1000 Pedometer in Children with Visual Impairments by Killeen Pritchard A Thesis Submitted in Partial Fulfillment of the Requirements

More information

VALIDATION OF HEAT FLUX TECHNOLOGY TO ASSESS ENERGY EXPENDITURE DURING EXERCISE. Erin L. Thomas

VALIDATION OF HEAT FLUX TECHNOLOGY TO ASSESS ENERGY EXPENDITURE DURING EXERCISE. Erin L. Thomas VALIDATION OF HEAT FLUX TECHNOLOGY TO ASSESS ENERGY EXPENDITURE DURING EXERCISE by Erin L. Thomas Bachelor of Science in Fitness/Wellness, University of Rhode Island, 2000 Masters of Science in Exercise

More information

Cycle journeys on the Anderston-Argyle Street footbridge: a descriptive analysis. Karen McPherson. Glasgow Centre for Population Health

Cycle journeys on the Anderston-Argyle Street footbridge: a descriptive analysis. Karen McPherson. Glasgow Centre for Population Health Cycle journeys on the Anderston-Argyle Street footbridge: a descriptive analysis Karen McPherson Glasgow Centre for Population Health March 2017 Key points: There were 116,334 cycle journeys made using

More information

Steps/day translation of the moderate-to-vigorous physical activity guideline for children and adolescents

Steps/day translation of the moderate-to-vigorous physical activity guideline for children and adolescents Adams et al. International Journal of Behavioral Nutrition and Physical Activity 2013, 10:49 RESEARCH Open Access Steps/day translation of the moderate-to-vigorous physical activity guideline for children

More information

23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN APRIL 2007

23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN APRIL 2007 23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN 16-20 APRIL 2007 AN INVESTIGATION INTO THE INTERRELATION BETWEEN THE INTERNAL AND EXTERNAL BALLISTICS OF FIRING A TP-T TANK AMMUNITION M. H.

More information

Gait Analyser. Description of Walking Performance

Gait Analyser. Description of Walking Performance Gait Analyser Description of Walking Performance This brochure will help you to understand clearly the parameters described in the report of the Gait Analyser, provide you with tips to implement the walking

More information

Legendre et al Appendices and Supplements, p. 1

Legendre et al Appendices and Supplements, p. 1 Legendre et al. 2010 Appendices and Supplements, p. 1 Appendices and Supplement to: Legendre, P., M. De Cáceres, and D. Borcard. 2010. Community surveys through space and time: testing the space-time interaction

More information

CHILDREN S PEDOMETER-DETERMINED PHYSICAL ACTIVITY DURING SCHOOL-TIME AND LEISURE-TIME

CHILDREN S PEDOMETER-DETERMINED PHYSICAL ACTIVITY DURING SCHOOL-TIME AND LEISURE-TIME Original Article CHILDREN S PEDOMETER-DETERMINED PHYSICAL ACTIVITY DURING SCHOOL-TIME AND LEISURE-TIME Charlotte A. Hardman 1, Pauline J. Horne 2, Ann V. Rowlands 3 1 Department of Experimental Psychology,

More information

Pedometer-Determined Physical Activity Levels of Youth

Pedometer-Determined Physical Activity Levels of Youth Journal of Physical Activity and Health, 2005, 2, 159-168 2005 Human Kinetics Publishers, Inc. Pedometer-Determined Physical Activity Levels of Youth Guy C. Le Masurier, Aaron Beighle, Charles B. Corbin,

More information

How are the values related to each other? Are there values that are General Education Statistics

How are the values related to each other? Are there values that are General Education Statistics How are the values related to each other? Are there values that are General Education Statistics far away from the others? Class Notes Measures of Position and Outliers: Z-scores, Percentiles, Quartiles,

More information

National Curriculum Statement: Determine quartiles and interquartile range (ACMSP248).

National Curriculum Statement: Determine quartiles and interquartile range (ACMSP248). Teacher Notes 7 8 9 10 11 12 Aim TI-Nspire CAS Investigation Student 90min To compare the height, weight, age and field positions of all football players from the 32 teams which participated in the 2010

More information

An Application of Signal Detection Theory for Understanding Driver Behavior at Highway-Rail Grade Crossings

An Application of Signal Detection Theory for Understanding Driver Behavior at Highway-Rail Grade Crossings An Application of Signal Detection Theory for Understanding Driver Behavior at Highway-Rail Grade Crossings Michelle Yeh and Jordan Multer United States Department of Transportation Volpe National Transportation

More information

SECTION 2 HYDROLOGY AND FLOW REGIMES

SECTION 2 HYDROLOGY AND FLOW REGIMES SECTION 2 HYDROLOGY AND FLOW REGIMES In this section historical streamflow data from permanent USGS gaging stations will be presented and discussed to document long-term flow regime trends within the Cache-Bayou

More information

Clutch Hitters Revisited Pete Palmer and Dick Cramer National SABR Convention June 30, 2008

Clutch Hitters Revisited Pete Palmer and Dick Cramer National SABR Convention June 30, 2008 Clutch Hitters Revisited Pete Palmer and Dick Cramer National SABR Convention June 30, 2008 Do clutch hitters exist? More precisely, are there any batters whose performance in critical game situations

More information

A SURVEY OF 1997 COLORADO ANGLERS AND THEIR WILLINGNESS TO PAY INCREASED LICENSE FEES

A SURVEY OF 1997 COLORADO ANGLERS AND THEIR WILLINGNESS TO PAY INCREASED LICENSE FEES Executive Summary of research titled A SURVEY OF 1997 COLORADO ANGLERS AND THEIR WILLINGNESS TO PAY INCREASED LICENSE FEES Conducted by USDA Forest Service Rocky Mountain Research Station Fort Collins,

More information

In Australia, survey instruments for the

In Australia, survey instruments for the Comparison of surveys used to measure physical activity Abstract Objective: To compare the level of agreement in results obtained from four physical activity (PA measurement instruments that are in use

More information

TECHNICAL NOTE THROUGH KERBSIDE LANE UTILISATION AT SIGNALISED INTERSECTIONS

TECHNICAL NOTE THROUGH KERBSIDE LANE UTILISATION AT SIGNALISED INTERSECTIONS TECHNICAL NOTE THROUGH KERBSIDE LANE UTILISATION AT SIGNALISED INTERSECTIONS Authors: Randhir Karma NDip: Eng (Civil) B. Tech Eng (Civil) M Eng (Hons) (Transportation) Auckland Traffic Service Group Manager

More information

Competitive Performance of Elite Olympic-Distance Triathletes: Reliability and Smallest Worthwhile Enhancement

Competitive Performance of Elite Olympic-Distance Triathletes: Reliability and Smallest Worthwhile Enhancement SPORTSCIENCE sportsci.org Original Research / Performance Competitive Performance of Elite Olympic-Distance Triathletes: Reliability and Smallest Worthwhile Enhancement Carl D Paton, Will G Hopkins Sportscience

More information

Data Set 7: Bioerosion by Parrotfish Background volume of bites The question:

Data Set 7: Bioerosion by Parrotfish Background volume of bites The question: Data Set 7: Bioerosion by Parrotfish Background Bioerosion of coral reefs results from animals taking bites out of the calcium-carbonate skeleton of the reef. Parrotfishes are major bioerosion agents,

More information

Procedia - Social and Behavioral Sciences 46 ( 2012 ) WCES 2012

Procedia - Social and Behavioral Sciences 46 ( 2012 ) WCES 2012 Available online at www.sciencedirect.com Procedia - Social and Behavioral Sciences 46 ( 2012 ) 4708 4712 WCES 2012 Differences in physical activity levels in 8-10 year-old girls who attend physical education

More information

A Pilot Trial of Three Very Brief Interventions for Physical Activity in Primary Care

A Pilot Trial of Three Very Brief Interventions for Physical Activity in Primary Care A Pilot Trial of Three Very Brief Interventions for Physical Activity in Primary Care M. Bijker, S. Pears, K. Morton, A. Prevost, E. Wilson, S. Sutton, W. Hardeman on behalf of the Very Brief Interventions

More information

BAUKJE DIJKSTRA, WIEBREN ZIJLSTRA, ERIK SCHERDER, YVO KAMSMA. Abstract. Introduction

BAUKJE DIJKSTRA, WIEBREN ZIJLSTRA, ERIK SCHERDER, YVO KAMSMA. Abstract. Introduction Age and Ageing 28; 37: 436 441 doi:.93/ageing/afn97 Published electronically 16 May 28 The Author 28. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved.

More information

Proposed Paralympic Classification System for Va a Information for National federations and National Paralympic Committees

Proposed Paralympic Classification System for Va a Information for National federations and National Paralympic Committees Proposed Paralympic Classification System for Va a Information for National federations and National Paralympic Committees Prepared by the research team Johanna Rosén, MSc, PhD student, member Paracanoe

More information

Tutorial for the. Total Vertical Uncertainty Analysis Tool in NaviModel3

Tutorial for the. Total Vertical Uncertainty Analysis Tool in NaviModel3 Tutorial for the Total Vertical Uncertainty Analysis Tool in NaviModel3 May, 2011 1. Introduction The Total Vertical Uncertainty Analysis Tool in NaviModel3 has been designed to facilitate a determination

More information

A Fair Target Score Calculation Method for Reduced-Over One day and T20 International Cricket Matches

A Fair Target Score Calculation Method for Reduced-Over One day and T20 International Cricket Matches A Fair Target Score Calculation Method for Reduced-Over One day and T20 International Cricket Matches Rohan de Silva, PhD. Abstract In one day internationals and T20 cricket games, the par score is defined

More information

Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G)

Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G) Institut fédéral de métrologie METAS METAS-N001/EN Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T (15 000 G) This document is a translation

More information

The Effects of Game Size on the Physical Activity Levels and Ball Touches of Elementary School Children in Physical Education

The Effects of Game Size on the Physical Activity Levels and Ball Touches of Elementary School Children in Physical Education ScholarWorks Kinesiology Faculty Publications and Presentations Department of Kinesiology 10-7-2013 The Effects of Game Size on the Physical Activity Levels and Ball Touches of Elementary School Children

More information

3D Turbulence at the Offshore Wind Farm Egmond aan Zee J.W. Wagenaar P.J. Eecen

3D Turbulence at the Offshore Wind Farm Egmond aan Zee J.W. Wagenaar P.J. Eecen 3D Turbulence at the Offshore Wind Farm Egmond aan Zee J.W. Wagenaar P.J. Eecen OWEZ_R_121_3Dturbulence_20101008 ECN-E--10-075 OCTOBER 2010 Abstract NoordzeeWind carries out an extensive measurement and

More information

Analysis of the Article Entitled: Improved Cube Handling in Races: Insights with Isight

Analysis of the Article Entitled: Improved Cube Handling in Races: Insights with Isight Analysis of the Article Entitled: Improved Cube Handling in Races: Insights with Isight Michelin Chabot (michelinchabot@gmail.com) February 2015 Abstract The article entitled Improved Cube Handling in

More information

Box-and-Whisker Plots

Box-and-Whisker Plots Lesson 75 Objectives Calculate quartile values for a data set Create a box-and-whisker plot Quartiles and Box-and-Whisker Plots Richard recorded the number of people that attended his team s minor league

More information

What do pedometer counts represent? A comparison between pedometer data and data from four different questionnaires

What do pedometer counts represent? A comparison between pedometer data and data from four different questionnaires Public Health Nutrition: 12(1), 74 81 doi:10.1017/s1368980008001973 What do pedometer counts represent? A comparison between pedometer data and data from four different questionnaires Katrien A De Cocker*,

More information

ANSI N323A and ANSI N323B

ANSI N323A and ANSI N323B ANSI N323A and ANSI N323B Test and Calibration of Portable Survey Instruments Presented at AMUG Conference Las Vegas, NV April 23-27, 2012 This presentation describes the additions, deletions, and modifications

More information

Algebra 1 Unit 7 Day 2 DP Box and Whisker Plots.notebook April 10, Algebra I 04/10/18 Aim: How Do We Create Box and Whisker Plots?

Algebra 1 Unit 7 Day 2 DP Box and Whisker Plots.notebook April 10, Algebra I 04/10/18 Aim: How Do We Create Box and Whisker Plots? Algebra I 04/10/18 Aim: How Do We Create Box and Whisker Plots? DO NOW 1) Find the mean, median, and mode of the data below 2) Which measure of central tendency do you believe best represents the data?

More information

Validity of Step Counting Methods over One Day in a Free-Living Environment

Validity of Step Counting Methods over One Day in a Free-Living Environment University of Tennessee, Knoxville Trace: Tennessee Research and Creative Exchange Masters Theses Graduate School 8-2018 Validity of Step Counting Methods over One Day in a Free-Living Environment Susan

More information

Abstract. Ulrik Röijezon, PhD and Paul Arden, MCCI

Abstract. Ulrik Röijezon, PhD and Paul Arden, MCCI Evaluation of long distance casting performance a comparison between three fly line prototypes and a commercially available long belly floating line #5 Ulrik Röijezon, PhD and Paul Arden, MCCI Abstract

More information

The use of pedometers for monitoring physical activity in children and adolescents: measurement considerations

The use of pedometers for monitoring physical activity in children and adolescents: measurement considerations Loughborough University Institutional Repository The use of pedometers for monitoring physical activity in children and adolescents: measurement considerations This item was submitted to Loughborough University's

More information

Analysis of Traditional Yaw Measurements

Analysis of Traditional Yaw Measurements Analysis of Traditional Yaw Measurements Curiosity is the very basis of education and if you tell me that curiosity killed the cat, I say only the cat died nobly. Arnold Edinborough Limitations of Post-

More information

Review Article Review of Prediction Models to Estimate Activity-Related Energy Expenditure in Children and Adolescents

Review Article Review of Prediction Models to Estimate Activity-Related Energy Expenditure in Children and Adolescents International Journal of Pediatrics Volume 2010, Article ID 489304, 14 pages doi:10.1155/2010/489304 Review Article Review of Prediction Models to Estimate Activity-Related Energy Expenditure in Children

More information

How to Make, Interpret and Use a Simple Plot

How to Make, Interpret and Use a Simple Plot How to Make, Interpret and Use a Simple Plot A few of the students in ASTR 101 have limited mathematics or science backgrounds, with the result that they are sometimes not sure about how to make plots

More information

Emerging Crash Trend Analysis. Mark Logan Department of Main Roads, Queensland. Patrick McShane Queensland Transport

Emerging Crash Trend Analysis. Mark Logan Department of Main Roads, Queensland. Patrick McShane Queensland Transport Emerging Crash Trend Analysis Mark Logan Department of Main Roads, Queensland Patrick McShane Queensland Transport The authors would like to acknowledge the assistance of Queensland Transport's Data Analysis

More information

Childrenʹs Step Counts on Weekend, Physical Education, and Non Physical Education Days

Childrenʹs Step Counts on Weekend, Physical Education, and Non Physical Education Days The College at Brockport: State University of New York Digital Commons @Brockport Kinesiology, Sport Studies and Physical Education Faculty Publications Kinesiology, Sport Studies and Physical Education

More information

Pedometry Methods for Assessing Free-Living Adults

Pedometry Methods for Assessing Free-Living Adults REviews Journal of Physical Activity and Health, 2011, 8, 445-453 2011 Human Kinetics, Inc. Pedometry Methods for Assessing Free-Living Adults Catrine Tudor-Locke, David R. Bassett, Michael F. Shipe, and

More information

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Calibration Requirements for Direct Reading Confined Space Gas Detectors : Calibration Requirements for Direct Reading Confined Space Gas Detectors However, the definition of bump test has always been a little slippery. Some manufacturers differentiate between a bump test that

More information

Use of Additional Through Lanes at Signalized Intersections

Use of Additional Through Lanes at Signalized Intersections Transportation Research Record 869 1 Use of Additional Through Lanes at Signalized Intersections PATRICK T. McCOY AND JOHN R. TOBIN One method sometimes used to increase the capacity of signalized intersections

More information