bakerhughes.com CENesis PHASE multiphase encapsulated production solution Keep gas out. Keep production flowing.
|
|
- Griffin Barber
- 5 years ago
- Views:
Transcription
1 bakerhughes.com CENesis PHASE multiphase encapsulated production solution Keep gas out. Keep production flowing.
2 Long horizontal laterals open more reservoir to the wellbore for greater conductivity and higher initial production rates...but they also create unique production challenges. Multiphase fluid flow, which is a challenge for artificial lift systems, is nearly always present in unconventional oil resource plays. And, while horizontal wellbore construction methods do expose more reservoir to the well for greater production, they also exacerbate the unique challenges associated with producing fluids mixed with gas. During production, as reservoir pressure depletes, natural gas is released from the reservoir and accumulates in the high side of the undulations along the horizontal lateral. When these gas accumulations or gas slugs break free and move up the wellbore they create low-flow or no-flow conditions in the artificial lift system. When these conditions occur they: nimpact system reliability due to cycling and gas lock conditions ninterrupt production nlimit ultimate reserve recovery
3 Eliminate production with an artificial lift solution specifically designed to se Improve return on investment with a multiphase production solution that encapsulates the entire electrical submersible pumping (ESP) system in a shroud to prevent gas slugs from entering the system. The CENesis PHASE multiphase encapsulated production solution naturally separates gas from the production stream, which stabilizes production and eliminates reliability issues associated with pump cycling and gas lock conditions. The system design also features a patented recirculation system to ensure adequate motor cooling for even greater reliability. The shroud provides a reservoir of fluid that allows the ESP system to continue operating when gas slugs displace fluid in the wellbore. The system design creates natural separation when the lighter natural gas continues to rise up the annulus while the heavier liquids enter the shroud to be produced through the ESP system. During gas slug events, the integrated recirculation system keeps continuous flow moving past the ESP motor to prevent overheating. Improve production and reserve recovery By eliminating the interference of gas slugs, the CENesis PHASE solution stabilizes production rates, improves efficiency, and eliminates down time caused by system cycling and gas locking. Through the life of the well, this continuous production profile more effectively draws down reservoir pressure to release additional hydrocarbons from the reservoir, improving ultimate reserve recovery and return on investment.
4 interruptions eparate gas slugs BEFORE they can enter the pump. The system includes the FLEXPumpER extended-range pump, during installation in deviated or horizontal wellbores which allows operators to produce over a wide flow range and and from downhole pressure changes. For wells with high eliminate costly system change outs as production declines. The sand content in the production stream, the CENesis PHASE FLEXPumpER pump has the industry s widest operating range. solution offers abrasion resistant pump technology and sand And, the wide vane openings standard in the FLEXPump series management devices. mixed-flow pump stage designs also help mitigate the impact of natural gas on the system. The integrated recirculation system is a key component of the CENesis PHASE design. By constantly diverting fluid past the ESP Enhance system reliability to reduce OPEX motor, the recirculation system prevents motor heating, which Incorporating a shroud into the system to separate gas slugs dramatically improves the reliability of the ESP. before they can enter the pump dramatically improves ESP reliability since there is no wear and tear on the system due The CENesis PHASE solution has improved the return on to cycling, gas locking, or pump overheating. The shroud also investment from hundreds of unconventional oil wells to date. provides mechanical protection for the motor lead extension
5 Make artificial lift operations even more effective with a full portfolio of gas-management technology and commercial models tailored to meet your business needs. BEFORE MaxRate gas control technology Combining a multiphase production system with unmatched gas-handling technology affords even greater operational flexibility in wells with high gas content in the fluid stream. MVP gas-handling systems merge a charge pump that compresses gas into solution with a primary pump designed specifically to lift multiphase fluids. AMBIT ESP monitoring services employing MaxRate gas control technology adds the last line of defense, detecting any anomalies AFTER MaxRate gas control technology caused by gas in the system and adjusting ESP system operating parameters to mitigate the impact Just as every well has a unique production profile, every operator has a unique set of business drivers, so Baker Hughes provides a range of commercial models to meet each customer s specific needs. Contact your local Baker Hughes representative to discuss the best technical and commercial solution to your multiphase production challenges. bakerhughes.com/phase
6 bakerhughes.com Disclaimer of Liability: This information is provided for general information purposes only and is believed to be accurate as of the date hereof; however, Baker Hughes Incorporated and its affiliates do not make any warranties or representations of any kind regarding the information and disclaim all express and implied warranties or representations to the fullest extent permissible by law, including those of merchantability, fitness for a particular purpose or use, title, non-infringement, accuracy, correctness or completeness of the information provided herein. All information is furnished as is and without any license to distribute. The user agrees to assume all liabilities related to the use of or reliance on such information. BAKER HUGHES INCORPORATED AND ITS AFFILIATES SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, PUNITIVE, EXEMPLARY OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER INCLUDING BUT NOT LIMITED TO ITS NEGLIGENCE Baker Hughes Incorporated. All rights reserved /2015
Intermittent Gas Lift and Gas Assist Plunger Lift
40 th Gas-Lift Workshop Houston, Texas, USA Oct. 23 27, 2017 Intermittent Gas Lift and Gas Assist Plunger Lift Claire Cherrey, Production Engineer Eagleford Anthony Williams, Production Engineer Bill Hearn,
More informationBeam Pumping to Dewater Horizontal Gas Wells
2 nd Annual Appalachian Basin Gas Well Deliquification Seminar Hilton Garden Inn, Pittsburg, PA June 13-14, 2011 Beam Pumping to Dewater Horizontal Gas Wells Lynn Rowlan, Echometer Co. J F Lea, Production
More informationArtificial Lift Basics Pre Reading
Artificial Lift Basics Pre Reading (Last Updated 7 January 2016) NOTICE AND DISCLAIMER The information contained herein and/or these workshop/seminar proceedings (WORK) was prepared by or contributed to
More information2010 Sucker Rod Pumping Workshop Optimizing Production and Reducing Costs by Solving Rod Pumping Problems With The Beam Gas Compressor
2010 Sucker Rod Pumping Workshop Optimizing Production and Reducing Costs by Solving Rod Pumping Problems With The Beam Gas Compressor 1 The Beam Gas Compressor is a Beam-Mounted gas compressor based on
More informationDownhole Diverter Gas Separator
7 th Annual Sucker Rod Pumping Workshop Renaissance Hotel Oklahoma City, Oklahoma September 27-30, 2011 Downhole Diverter Gas Separator Jim McCoy Ken Skinner, Lynn Rowlan, Dieter Becker - Echometer Company
More informationAdvanced Intermittent Gas Lift Utilizing a Pilot Valve
Gas Well Deliquification Workshop Sheraton Hotel, Denver, Colorado February 29 March 2, 2016 Advanced Intermittent Gas Lift Utilizing a Pilot Valve Matt Young Technical Sales Manager Intermittent Gas Lift
More informationSucker Rod Lift Downhole Gas Separators Proposed Industry Testing
11 th Annual Sucker Rod Pumping Workshop Renaissance Hotel Oklahoma City, Oklahoma September 15-18, 2015 Sucker Rod Lift Downhole Gas Separators Proposed Industry Testing Norman W. Hein, Jr. Oil & Gas
More informationPacker-Type Gas Separator with Seating Nipple
8 th Annual Sucker Rod Pumping Workshop Renaissance Hotel Oklahoma City, Oklahoma September 25-28, 2012 Packer-Type Gas Separator with Seating Nipple Jim McCoy Lynn Rowlan, Dieter Becker, Ken Skinner -
More informationDon-Nan Pump & Supply. Don-Nan Pump & Supply 1
Don-Nan Pump & Supply Don-Nan Pump & Supply 1 GAS PROBLEMS IN THE WELL Gas is found in two forms in oil wells: (1) in solution with the well fluid, and (2) as a free gas in the formation. Gas is held in
More informationDownhole Gas Separator Selection
Gas Well Deliquification Workshop Sheraton Hotel, February 17 20, 2013 Downhole Gas Separator Selection James N. McCoy & Lynn Rowlan Feb. 17 20, 2013 2 Downhole Gas Separator Selection Many operators with
More informationIntermittent Gas Lift Utilizing a Pilot Valve
39 th Gas-Lift Workshop Houston, Texas, USA May 16 20, 2016 Intermittent Gas Lift Utilizing a Pilot Valve Matt Young Technical Sales Manager May 16 20, 2016 2015 Gas-Lift Workshop 1 Intermittent Gas Lift
More informationDownhole Gas Separator Selection
4th Annual Appalachian Basin Gas Well Deliquification Workshop Marietta College, Marietta, Ohio June 3 5, 2013 Downhole Gas Separator Selection Lynn Rowlan Proper Downhole Gas Separator Selection Critical
More informationDownhole Gas Separation Performance
Gas Well Deliquification Workshop Sheraton Hotel, February 20 22, 2017 Downhole Gas Separation Performance Lynn Rowlan Overview Free gas interfering with liquid filling the pump is a major operational
More informationHigh Pressure Continuous Gas Circulation: A solution for the
Gas Well Deliquification Workshop Sheraton Hotel, February 20 22, 2017 High Pressure Continuous Gas Circulation: A solution for the Pressure Dependent Permeability of the Haynesville Shale? Bill Elmer,
More informationFundamentals Of Petroleum Engineering PRODUCTION
Fundamentals Of Petroleum Engineering PRODUCTION Mohd Fauzi Hamid Wan Rosli Wan Sulaiman Department of Petroleum Engineering Faculty of Petroleum & Renewable Engineering Universiti Technologi Malaysia
More informationGas Well Deliquification Workshop. Gas Assisted Rod Pump
Gas Well Deliquification Workshop Sheraton Hotel, February 23 25, 2015 Gas Assisted Rod Pump Daryl Mazzanti Executive VP Operations GARP Services LLC A subsidiary of Evolution Petroleum Corp (EPM- NYSEMKT)
More informationA LIFE OF THE WELL ARTIFICIAL LIFT STRATEGY FOR UNCONVENTIONAL WELLS
A LIFE OF THE WELL ARTIFICIAL LIFT STRATEGY FOR UNCONVENTIONAL WELLS Jay Miller Sales Manager Production Lift Companies Inc. Artificial Lift & Production Congress January 29, 2019 Unconventional Wells
More informationGas Locked Pumps are NOT Gas Locked!
9 th Annual Sucker Rod Pumping Workshop Renaissance Hotel Oklahoma City, Oklahoma September 17-20, 2013 Gas Locked Pumps are NOT Gas Locked! Lynn Rowlan Ken Skinner Echometer Company Introduction Gas Locked
More informationTroubleshooting Gas-lift Wells Using Dual Shot Acoustic Technique
2018 Artificial Lift Strategies for Unconventional Wells Workshop Cox Convention Center, Oklahoma City, OK February 4 7, 2018 Troubleshooting Gas-lift Wells Using Dual Shot Acoustic Technique Shea Province
More informationRestoring Fluid Flow in Tubing Strings
Restoring Fluid Flow in Tubing Strings Andrew Roth, Product Manager Fike Corporation Fike Hydraulic Tubing Drains (HTD) for use with deep hole drilling tools, downhole devices and other oil and off shore
More informationIntrinsically Safe Acoustic Instrument Used in Troubleshooting Gas Lift Wells
Gas Well Deliquification Workshop Sheraton Hotel, Denver, Colorado February 17 20, 2013 Intrinsically Safe Acoustic Instrument Used in Troubleshooting Gas Lift Wells Lynn Rowlan, Echometer Company Carrie-Anne
More informationPressure Activated Chamber Technology (PACT)
Gas Well Deliquification Workshop Sheraton Hotel, February 23-26, 2009 Pressure Activated Chamber Technology (PACT) A new artificial lift system for CBM wells Leslie Lam, Black Hills Exploration Ryan Davis,
More informationTwo Short Topics 1) Using Compressors More Effectively 2) Improving Upon Poor-Boy Gas-Lift
Gas Well Deliquification Workshop Sheraton Hotel, Denver, Colorado February 17-20, 2013 Two Short Topics 1) Using Compressors More Effectively 2) Improving Upon Poor-Boy Gas-Lift Jim Hacksma Consultant
More informationAcoustic Techniques to Monitor and Troubleshoot Gas-lift Wells
37 th Gas-Lift Workshop Houston, Texas, USA February 3 7, 2014 Acoustic Techniques to Monitor and Troubleshoot Gas-lift Wells Carrie-Anne Taylor, Engineer Lynn Rowlan, Engineer Echometer Company Feb. 3-7,
More informationInternational Journal of Petroleum and Geoscience Engineering Volume 03, Issue 02, Pages , 2015
International Journal of Petroleum and Geoscience Engineering Volume 03, Issue 02, Pages 116- ISSN: 2289-4713 Improving Reservoir Recovery Factor Using Enhanced Electrical Submersible Pump Design; a Case
More informationAcoustic Troubleshooting of Coal Bed Methane Wells
Gas Well Deliquification Workshop Sheraton Hotel, February 29 March 2, 2016 Acoustic Troubleshooting of Coal Bed Methane Wells O. Lynn Rowlan and Dieter Becker lynn@echometer.com Introduction Distance
More information902 MHz 928 MHz Waterproof Dipole 2 dbi Antenna, IP67
902 MHz 928 MHz Waterproof Dipole 2 dbi Antenna, IP67 ORDERING INFORMATION Order Number Description 001-0011 900 MHz Waterproof Dipole Antenna for Reverse Polarity SMA Connector, IP67 080-0013 U.FL to
More informationiphone Application Slurry Pump System Calculator Instructions
iphone Application Slurry Pump System Calculator Instructions Press + to start a New Calculation Enter in Title of the Calculation. Press on saved calculation to open and start calculation. Select U.S.
More informationUsing Gas Lift to Unload Horizontal Gas Wells
Gas Well Deliquification Workshop Sheraton Hotel, Denver, Colorado February 27 March 2, 211 Using Gas Lift to Unload Horizontal Gas Wells Rob Sutton Marathon Oil Company Conventional Gas Lift Application
More informationJim McCoy. Tubing Anchor Effect on Pump Fillage. Lynn Rowlan Tony Podio Ken Skinner. Gas Well Deliquification Workshop.
Gas Well Deliquification Workshop Sheraton Hotel, February 23 26, 2014 Tubing Anchor Effect on Pump Fillage Jim McCoy Jim@echometer.com Lynn Rowlan Tony Podio Ken Skinner Gas Separator Overview Natural
More informationPump Fillage Problem Overview. Jim McCoy. 9 th Annual Sucker Rod Pumping Workshop. Renaissance Hotel Oklahoma City, Oklahoma September 17-20, 2013
9 th Annual Sucker Rod Pumping Workshop Renaissance Hotel Oklahoma City, Oklahoma September 17-20, 2013 Pump Fillage Problem Overview Jim McCoy Lynn Rowlan Tony Podio Ken Skinner Echometer Company Jim@echometer.com
More informationOptimizing Chemical Injection
Gas Well Deliquification Workshop Sheraton Hotel, February 17 20, 2013 Optimizing Chemical Injection Dave Barry ABB Totalflow Charlie Parker TXAM Pumps Deliquification Options 2 Foamers How do Chemical
More informationDownhole Pressure Boosting: A production enhancement tool for both dry and liquid loaded Gas wells
Gas Well Deliquification Workshop Adams Mark Hotel, February 25-27, 2008 Downhole Pressure Boosting: A production enhancement tool for both dry and liquid loaded Gas wells Norman Liley, Project Director
More informationIs The Selection Of Artificial Lift
Appalachian Basin Gas Well Deliquification Seminar Marietta College, Marietta, Ohio June 7-8, 2010 Is The Selection Of Artificial Lift Too Arbitrary? Jim Hacksma - Consultant How Is Artificial Lift (AL)
More informationAnomaly Marker Method for Gas-Lift Wells
35 th Gas-Lift Workshop Houston, Texas, USA February 6 10, 2012 Anomaly Marker Method for Gas-Lift Wells Carrie-Anne Taylor, Echometer Company Lynn Rowlan, Echometer Company Feb. 6-10, 2012 2012 Gas-Lift
More informationAppalachian Basin Gas Well. Marietta College, Marietta, Ohio June 7-8, Development. Robert McKee, P.E. Design Engineer Multi Products Company
Appalachian Basin Gas Well Marietta College, Marietta, Ohio June 7-8, 2010 Casing Plunger Applications & Development Robert McKee, P.E. Design Engineer Multi Products Company Casing Plunger A.L. Lift Without
More informationDrilling Efficiency Utilizing Coriolis Flow Technology
Session 12: Drilling Efficiency Utilizing Coriolis Flow Technology Clement Cabanayan Emerson Process Management Abstract Continuous, accurate and reliable measurement of drilling fluid volumes and densities
More informationDown-Hole Gas Separator Performance Simulation
10 th Annual Sucker Rod Pumping Workshop Renaissance Hotel Oklahoma City, Oklahoma September 16-19, 2014 Down-Hole Gas Separator Performance Simulation Jim McCoy Ken Skinner, Lynn Rowlan - Echometer Company
More informationOEM Liquid-Flowmeter
OEM Liquid-Flowmeter (With State-of-the-Art Technology) Rev.: 1.2 Seite 1 / 6 OEM-Liquid-Flowmeter Functional Principle The OEM Liquid-Flowmeters are working with ultrasound according to the Time-of-Flight
More informationOptimizing Production Throughout the Well s Lifespan. Gas Lift
Optimizing Production Throughout the Well s Lifespan Gas Lift Apergy Leading Brands. Leading Solutions. Apergy s artificial lift division is a team of industry-leading companies that utilize their collective
More informationPub.No Flushing out your heat transfer system was a dirty job, a big expense, and a serious bummer.
Pub.No.7239480 Flushing out your heat transfer system was a dirty job, a big expense, and a serious bummer. Now, the new Therminol FF Cleaning System makes it quicker, cheaper and easier. NOW,it s as easy
More informationAn Improved Understanding of LNAPL Behavior in the Subsurface LNAPL - Part 1
An Improved Understanding of LNAPL Behavior in the Subsurface LNAPL - Part 1 Dave Thomas Copyright 2011 Chevron Corporation All Rights Reserved Copyright claimed throughout, except where owned by others
More informationImproving Performance of Gas Lift Compressors in Liquids-Rich Gas Service
2019 Artificial Lift Strategies for Unconventional Wells Workshop Cox Convention Center, February 11-14, 2019 Improving Performance of Gas Lift Compressors in Liquids-Rich Gas Service Will Nelle Bill Elmer,
More informationContinuous Injection of Hydrate Inhibitor in Gas Lift Gas to Mitigate Downtime Due to Downhole Annular Plugging
32 nd Gas-Lift Workshop The Hague, The Netherlands February 2-6, 2009 Continuous Injection of Hydrate Inhibitor in Gas Lift Gas to Mitigate Downtime Due to Downhole Annular Plugging John R. Cliver and
More information863 MHz 870 MHz Dipole 2 dbi Antenna for RP SMA
863 MHz 870 MHz Dipole 2 dbi Antenna for RP SMA ORDERING INFORMATION Order Number Description 001-0028 868 MHz Dipole Antenna for Reverse Polarity SMA Connector 080-0001 U.FL to SMA Bulkhead Cable, 1.13mm
More informationPlunger Lift: SCSSSV Applications
Gas Well Deliquification Workshop Adams Mark Hotel, February 23-26, 2009 Plunger Lift: SCSSSV Applications William Hearn, Weatherford Stathis Kitsios, Sachin Shinde, Dick Klompsma, Ewout Biezen, NAM Plunger
More informationPressure Test Tubing for Leak
11 th Annual Sucker Rod Pumping Workshop Renaissance Hotel Oklahoma City, Oklahoma September 15-18, 2015 Pressure Test Tubing for Leak Joseph Norman, FORTY A&M LLC http://www.fluidlevels.com/ Lynn Rowlan
More informationTL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0
TL-12 FLUSH TANK Manual Ref. # MN-??? REVISION 1.0 Polyurethane Machinery Corp. Corporate: 1 Komo Dr, Lakewood, NJ 08701 Manufacturing: 2 Komo Dr, Lakewood, NJ 08701 Phone: 732-415-4400 Fax: 732-364-4025
More informationGas Well Deliquification Workshop Sheraton Hotel, Denver, Colorado February 20 22, 2017
Gas Well Deliquification Workshop Sheraton Hotel, Denver, Colorado February 20 22, 2017 Utilizing Gas Assisted Plunger Lift Matt Young Presenter Flowco Production Solutions Dave Dahlgren Flowco Production
More informationPlunger Lift Algorithms A Review
Gas Well Deliquification Workshop Sheraton Denver Hotel ; 2016 Plunger Lift Algorithms A Review David Cosby, P.E. Shale Tec LLC Learning Points owhat is an algorithm? ocontinuous vs conventional plunger
More informationAcid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company
Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The Acid-Rite ph Adjustment System is designed for use with Axiall
More informationModelling Gas Well Liquid (Un)Loading
Gas Well Deliquification Workshop Adams Mark Hotel, February 25-27, 28 Modelling Gas Well Liquid (Un)Loading Kees Veeken (NAM, Assen) Murat Kerem (Shell, Rijswijk) Objectives of Modelling Liquid loading
More informationRESERVOIR DRIVE MECHANISMS
RESERVOIR DRIVE MECHANISMS There are several ways in which oil can be naturally displaced and produced from a reservoir, and these may be termed mechanisms or "drives". Where one mechanism is dominant,
More informationPlunger Fall Velocity Model
Gas Well Deliquification Workshop Sheraton Hotel, Denver, Colorado February 19 22, 2012 Plunger Fall Velocity Model Lynn Rowlan & James N. McCoy James F Lea Rick Nadkrynechny Carolyn Cepuch What s know
More informationPlunger Fall Velocity Model
Gas Well Deliquification Workshop Sheraton Hotel, Denver, Colorado February 19 22, 2012 Plunger Fall Velocity Model Lynn Rowlan & James N. McCoy James F Lea Rick Nadkrynechny Carolyn Cepuch New Plunger
More informationSheet Metal Design Guidelines
Sheet Metal Design Guidelines Issue XVI, Dec 2015 2 Copyright Notice Geometric Limited. All rights reserved. No part of this document (whether in hardcopy or electronic form) may be reproduced, stored
More informationSEMATECH Provisional Test Method for Pressure Cycle Testing Filter Cartridges Used in UPW Distribution Systems
Provisional Test Method for Pressure Cycle Testing Filter Cartridges Used in UPW Distribution Systems Technology Transfer 92010941B-STD and the logo are registered service marks of, Inc. 1996, Inc. Provisional
More informationQPF Pneumatic Fenders. Operation Manual A EUROTECH BENELUX COMPANY
QPF Pneumatic Fenders Operation Manual A EUROTECH BENELUX COMPANY Introduction The QuayQuip QPF Pneumatic Fender has an air-filled cylindrical body with hemispherical ends. One or both ends may have a
More informationA Combined Experimental & Numerical Research Program to Develop a Computer Simulator for Intermittent Gas-lift
37 th Gas-Lift Workshop Houston, Texas, USA February 3 7, 2014 A Combined Experimental & Numerical Research Program to Develop a Computer Simulator for Intermittent Gas-lift Bordalo, S. (1), Barreto, M.
More information32 nd Gas-Lift Workshop. Optimizing Subsea Well Kick-off Operations Case Study Using FlowLift2
32 nd Gas-Lift Workshop The Hague, The Netherlands February 2-6, 2009 Optimizing Subsea Well Kick-off Operations Case Study Using FlowLift2 Denise Lima Artificial Lift Engineer Galileu de Oliveira Artificial
More information31 st Gas-Lift Workshop
31 st Gas-Lift Workshop Houston, Texas February 4-8, 2008 NEW REQUIREMENTS TO GAS LIFT VALVES Øyvind Stokka & Erling Kleppa Petroleum Technology Company This presentation is the property of the author(s)
More informationSPECIFICATIONS APCEPH1
APCEPH1 ph CONTROLLER SPECIFICATIONS APCEPH1 Input voltage 120 Volts AC Maximum amperage 14.5 amps @ 120 VAC ph Accuracy +/- 0.2 ph ph Control range Adjustable 4.5 8.5 ph Weight < 1 lbs Dimensions 3" x
More information01 TM SuperModified Testing with RS485 <> USB
Testing with RS485 USB 1. Preinstalled cables The Supermodified controller comes with several wires soldered. By default the power and RS485 cables are soldered. I2C and legacy RC servo interface cables
More informationHydraulic Piston Pump Field Trial
Gas Well Deliquification Workshop Sheraton Hotel, February 23 25, 215 Hydraulic Piston Pump Field Trial Kees Veeken, Sjoerd den Daas, Tim Ebare, Erik Riemsma, Bert Lugtmeier (Shell-NAM, NL) David Bolt,
More informationTROUBLESHOOT ROD PUMPED WELLS USING TUBING FLUID LEVEL SHOTS
10 th Annual Sucker Rod Pumping Workshop Renaissance Hotel Oklahoma City, Oklahoma September 16-19, 2014 TROUBLESHOOT ROD PUMPED WELLS USING TUBING FLUID LEVEL SHOTS John Sparks, COG OPERATING LLCU Lynn
More informationHow does an unstable GLV affect the producing zones?
37 th Gas-Lift Workshop Houston, Texas, USA February 3 7, 2014 How does an unstable GLV affect the producing zones? Frode Hveding Vice President Reservoir 2014 Gas-Lift Workshop 1 Agenda Description of
More informationPITFALLS OF RUNNING CONVENTIONAL PRODUCTION LOGGING IN HORIZONTAL/HIGHLY DEVIATED WELLS: A CASE STUDY
PITFALLS OF RUNNING CONVENTIONAL PRODUCTION LOGGING IN HORIZONTAL/HIGHLY DEVIATED WELLS: A CASE STUDY Waqar Khan, Venkataraman Jambunathan, and Luis Quintero, Halliburton Copyright 2015, held jointly by
More informationThe Automotive Landscape:
The Automotive Landscape: Navigating New Waters Automotive News Canada Congress February 17 nd, 2017 Michael Robinet, Managing Director, Automotive Advisory Solutions 2 Industries We Serve Financial Markets
More informationGas Well Deliquification Workshop. Sheraton Hotel, Denver, Colorado February 29 March 2, 2016
Gas Well Deliquification Workshop Sheraton Hotel, February 29 March 2, 2016 Enriched Inflow Performance Relationship (EIPR) Curves for Simultaneous Selection of Target Rate & Pump Setting Depth While Visualizing
More informationDuPont Kalrez. Oil and Gas Product Selector Guide. Technical Information April 2017
DuPont Kalrez Oil and Gas Product Selector Guide Technical Information April 2017 DuPont has more than 30 years of experience providing perfluoroelastomer seals to the oil and gas industry. Over this time,
More informationSafe hydraulics for hydroforming presses. more finished product to be created from less raw material.
profile Drive & Control Safe hydraulics for hydroforming presses Safety Standard Guidelines for Hydraulic Presses In several western regions, safety standards exist that describe how to achieve safe control
More informationChapter 8: Reservoir Mechanics
PTRT 1472: Petroleum Data Management II Chapter 8: Reservoir Mechanics - Reservoir drives Types of Natural Gas Reservoir Fluids Natural gas is petroleum in a gaseous state, so it is always accompanied
More informationNew Single Well Gas Lift Process Facilitates Fracture Treatment Flowback
Gas Well Deliquification Workshop Sheraton Hotel, February 23-26, 2009 New Single Well Gas Lift Process Facilitates Fracture Treatment Flowback William G. Elmer, P.E. EOG Resources, Inc. Introduction Current
More informationVARIABLE SLIPPAGE PUMP
VARIABLE SLIPPAGE PUMP Dover Artificial Lift, part of Dover Energy, is a team of industry-leading companies that utilize their collective resources to help oil & gas producers optimize revenues, profitability,
More informationPRODUCTION AND OPERATIONAL ISSUES
PRODUCTION AND OPERATIONAL ISSUES Dr. Ebrahim Fathi Petroleum and Natural Gas Engineering Department West Virginia University Audience and Date March 2, 2016 Summary Production and Operational Issues Shale
More informationDescribe Flammable Gas Measurement
Training Module Describe Flammable 100% 90% C 80% No Combustion 70% 60% 50% 40% 30% 20% UEL B Combustion No Combustion 10% 0% LEL A Human Development HDC Human Development All rights reserved. No part
More informationUSER MANUAL. DM65 Manual Flush/Tilt Combo Mount
USER MANUAL DM65 Manual Flush/Tilt Combo Mount 1 D1_1.11.11.indd 1 ! CAUTION When using this mounting system, basic precautions should be followed, including: Follow the entire installation/user s manual
More informationHydroPull. Extended-Reach Tool. Applications
Extended-Reach Tool HydroPull This tool incorporates a cycling valve that momentarily interrupts the flow to create water-hammer pressure pulses inside coiled or jointed tubing used in horizontal well
More informationDan Casey Pro-Seal Lift Systems, Inc.
Gas Well Deliquification Workshop Sheraton Hotel, Denver, Colorado February 17 20, 2013 Dan Casey Pro-Seal Lift Systems, Inc. Advantage Soapsticks Soapsticks are common; Soapsticks are effective; Soapsticks
More informationLow GWP R-404A Alternatives for Commercial Refrigeration. Barbara H. Minor Dr. Frank Rinne DuPont Fluorochemicals
Low GWP R-404A Alternatives for Commercial Refrigeration Barbara H. Minor Dr. Frank Rinne DuPont Fluorochemicals Chillventa Nűrnberg October 9-11, 2012 Topics Regulatory Environment Properties of New Refrigerants
More informationTOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual
TOP VALVE Pat. #5,857,486 & 5,944,050 Mid-Range Pressure 50 232 PSIG Back Pressure and Pressure Relief Valves Instruction Manual Please Note: This instruction manual provides detailed information and instructions
More information36 th Gas-Lift Workshop. Reverse Flow Check Valve Reliability and Performance Testing of Gas Lift Barrier Check Valves
36 th Gas-Lift Workshop Stavanger, Norway February 4 8, 2013 Reverse Flow Check Valve Reliability and Performance Testing of Gas Lift Barrier Check Valves Jason Kamphaus, Senior Project Manager Schlumberger
More informationDe-Liquification and Revival of Oil & Gas Wells using Surface Jet Pump (SJP) Technology
Gas Well Deliquification Workshop Sheraton Hotel, February 19 22, 2012 De-Liquification and Revival of Oil & Gas Wells using Surface Jet Pump (SJP) Technology Colin Morrison & Sacha Sarshar, Caltec, UK
More informationCaltec. The world leader in Surface Jet Pump (SJP) and compact separation systems for upstream oil and gas production enhancement
Caltec brings simple passive technology that enables oil and gas operators to harness the kinetic energy of the production process to enhance their production, extending economic field life and reducing
More informationInnovating Gas-Lift for Life of Well Artificial Lift Solution. The Unconventional Solution!
Innovating Gas-Lift for Life of Well Artificial Lift Solution The Unconventional Solution! Glenn Wilde Optimum Production Technologies Inc. Revive Energy Corp. Unconventional Oil & Gas Resources Unconventional
More informationBarrier Philosophy for Wells on Gas lift and Ways of Reducing HSE Risks. Alan Brodie Feb 2011 For more info visit
Barrier Philosophy for Wells on Gas lift and Ways of Reducing HSE Risks Alan Brodie Feb 2011 For more info visit www.ptc.as Introduction Gas Lifted Well Integrity Management Incremental HSE risks Case
More informationNATIONAL COMMISSION FOR THE CERTIFICATION OF CRANE OPERATORS (NCCCO) LIFT DIRECTOR TOWER CRANES LOAD CHART MANUAL
NATIONAL COMMISSION FOR THE CERTIFICATION OF CRANE OPERATORS (NCCCO) LIFT DIRECTOR TOWER CRANES LOAD CHART MANUAL HAMMERHEAD TOWER CRANE CHART D LUFFING BOOM TOWER CRANE CHART F These charts have been
More information37 th Gas-Lift Workshop Houston, Texas, USA February 3 7, Alan Brodie, PTC
37 th Gas-Lift Workshop Houston, Texas, USA February 3 7, 2014 Gas Lift Innovations which deliver more production and reduce or simplify well interventions Alan Brodie, PTC Feb. 3-7, 2014 2014 Gas-Lift
More informationMaterial Safety Data Sheet Vanilla Bean Fragrance Oil
Material Safety Data Sheet Vanilla Bean Fragrance Oil Product Name Contact Info Emergency Phone Number Section I: General Information Vanilla Bean Fragrance Oil SoapGoods Inc. 1824 Willow Trail Pkwy Norcross,
More information86BSD Backside Digital Output
Stainless steel with O-ring seal Pressure/temperature read-out Backside digital output ASIC calibrated Absolute, gage Cable/connector option Low power option DESCRIPTION The 86BSD is a small profile, media
More informationDistributed Acoustic Sensor for Oil and Gas
Distributed Acoustic Sensor for Oil and Gas :Distributed Acoustic System Standard Communications Fiber The entire system consists of only two parts: a standard communications fiber that is positioned on
More informationECHO INSTRUCTION GUIDE WARNING STATEMENT & INSTRUCTIONS Thank you for your purchase of the Echo Trigger. This product should be used only after
ECHO INSTRUCTION GUIDE WARNING STATEMENT & INSTRUCTIONS Thank you for your purchase of the Echo Trigger. This product should be used only after reading and understanding these warnings and the instructions
More information6PS SERIES HERMETIC STAINLESS STEEL PRESSURE SWITCH Introduction
6PS SERIES HERMETIC STAINLESS STEEL PRESSURE SWITCH Introduction KLIXON 6PS series stainless steel pressure switch is a snap-acting, all welded device hermetically sealed switch contacts. All switch components
More informationPacemaker Plunger Operations in Greater Natural Buttes
Gas Well Deliquification Workshop Sheraton Hotel, February 23-26, 2009 Pacemaker Plunger Operations in Greater Natural Buttes Bennie Allen (Anadarko), Mac Burton (Anadarko) & Justin Lake (IPS) Agenda How-it-works
More informationBS Series Basket Strainer
BS Series Basket Strainer Operating, Installation, & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems. Dated 04-26-12 PRESSURE DROP SIMTECH strainers are engineered to offer the lowest
More informationSizing, Selection, and Installation of Pressure-relieving Devices in Refineries
Sizing, Selection, and Installation of Pressure-relieving Devices in Refineries Part I Sizing and Selection Downstream Segment API STANDARD 520 EIGHTH EDITION, DECEMBER 2008 Special Notes API publications
More informationMaterial Safety Data Sheet
Material Safety Data Sheet Rice Flower & Shea Cybilla Fragrance Oil Product Name Contact Info Emergency Phone Number Section I: General Information Rice Flower & Shea Cybilla Fragrance Oil SoapGoods Inc.
More informationthen the work done is, if the force and the displacement are in opposite directions, then the work done is.
1. What is the formula for work? W= x 2. What are the 8 forms of energy? 3. Write the formula for the following: Kinetic Energy Potential Energy 4. If the force and the displacement are in the same direction,
More informationPerforating Center of Excellence TESTING SERVICES OVERVIEW
Perforating Center of Excellence TESTING SERVICES OVERVIEW Jet Research Center (JRC) is the leader in energetic research and testing for the oil and gas industry. Since introducing jet perforators for
More informationFlow Scanner. Production logging in multiphase horizontal wells
Flow Scanner Production logging in multiphase horizontal wells Applications Multiphase flow profiling in nonvertical wells Identification of fluid and gas entries in multiphase well or liquid in gas wells
More information