EPP pneumatic pumping stations PRODUCT CATALOG
|
|
- Barrie Barber
- 5 years ago
- Views:
Transcription
1 EPP pneumatic pumping stations PRODUCT CATALOG Version
2 Technical data Comply with harmonized norms: PN-EN , PN-EN , PN-EN Comply with the requirements of the Regulation of the European Parliament and of the Council (EU) No. 305/2011. Lifting height up to 10 bars (higher pressure for special performances). Free passage from DN80 to DN200. Applications Sewage pumping over very large distances and/or heights (pumping pressure to 10 bars). Municipal or industrial sewage. Main, zonal or local pumping station. Pumping sewage in sections threaten by putrescibility in the discharge pipe (periodic aeration and/or emptying of the pipeline from the wastewater function). Advantages For Users 1. Refresh pumped sewage and prevent putrefying during transport. 2. Allow periodic aeration and/or entire emptying of the pressing pipeline using compressed air. 3. Allow the possibility to adjust the efficiency of the pumping station to the current requirements without replacing any equipment. 4. Enable safe and hygienic operation by placing a technological part in the dry chamber. 5. Do not cause any silting or formation of sludge and surface scum being the result of sedimentation and floatation in the retention chamber. For Engineers 1. Allow the possibility to pump sewage over very large distances and/or heights (working pressure 8-10 bars). 2. Allow the possibility to adapt the capacity of the system to current needs without any necessity to replace any devices. 3. Allow the possibility to abandon the installation of aeration air release valves in the pressing pipeline. 4. The possibility of installation in close proximity with residential buildings or outbuildings. 5. No not need to dose chemical substances that eliminate waste purification.
3 Operating principle of EPP pneumatic pumping station The EPP pneumatic pumping station constitutes a complete and fully automated installation. The operating principle of the EPP pneumatic pumping station consists in a cyclical and alternate occurrence of two operating phases of the pumping station: the filling phase and the pumping phase. In the filling phase, sewage flows to the vertical external pipe retention chamber; from there, it flows through the inflow well to the working chambers through open inlet valves. The outlet valve is open so that air could be released from the working chambers, while all the other valves remain closed. Once the working chambers have been filled with sewage, waste continues to accumulate in the inflow well and in the pipe retention chamber. Once the adequate level of sewage has been reached in the pipe retention chamber, the sewage pumping phase is switched on, which continues until the switching off level has been reached. The pumping phase starts with the outlet valves being closed. The inlet elbow valve is closed under the influence of control air supplied to the working chamber by opening of the control valve. Once the inlet valve is closed, the working air valve is open, through which compressed air is pumped, as a result of which the elbow check valve is open that is located on the outlet from the working chambers, while sewage is forced out with compressed air from the working chamber and is forced into the pressure conduit. Pumping of sewage continues until the time set has elapsed or an adequate level in the working chamber has been reached. Then, the outlet valve is open and air that is inside the working chamber is decompressed in the suppressor, after which the biofilter is located. After the completion of the compression phase, the system enters the filling phase. These cycles are repeated, and air is alternately forced into the working chambers until the level of sewage in the retention chamber has reached the minimum. One of the chief advantages of the EPP pneumatic pumping station is the function of periodical (e.g. at night) entire emptying of the pressure conduit from sewage using compressed air. In this manner, excessive putrefying of sewage in the pressure conduit is prevented, and odors that are hazardous to human life in the release wells are eliminated. Range of parameters Type Maximum inflow Minimum diameter of pressing pipeline Minimum number of compressors Number of working tanks Minimum retention capacity* EPP [m 3 /h] [mm] [psc.] [psc.] [l] * Minimum retention capacity may be decreased when the inflow is less then maximum or/and the number of compressors will be reduced.
4 EPP pneumatic pumping station construction External technological container Source of steering gas Control valves Biofilter of decompressed air Suppresor of decompressed air Dry chamber of lift station Inlet well Inlet chamber External pipe retention tank Working tank Pneumatic and control column Elbow check valve (energy efficient valve) Alarm sensor Inlet chamber Inspection window Working tank Upper control sensor Cut-off knife gate valves Buttom control sensor Vibration compensator COMBI elbow check valve
5 OFFICE ADDRESS: EkoWodrol Ltd. 13 Slowianska Str Koszalin, Poland CONTACT US: Phone:
Combination Air Valve
Combination Air Valve For Sewage and Wastewater Model C50 Installation, Operation and Maintenance Manual (IOM) Table of Contents General... Page 2 Safety... Page 2 Operational Data... Page 3 Materials
More informationDAV - WP DAV - WP. Wastewater Air Valves. Product Catalogue. (Wastewater Air Valves) DAV - WP
DAV - WP Wastewater Air Valves DAV - WP (Wastewater Air Valves) Product Catalogue DAV - WP DAV Series??? DAV-WP General DAV-WP Wastewater Air Valves The DAV-WP valve has been designed for efficient discharge
More informationDigester Processes. 1. Raw Sludge Pumping System
Digester Processes 1. Raw Sludge Pumping System Removes accumulated sludge from the primary clarifiers, pumped through 1 of 2 pipes either 150 or 200mm in diameter (Fig. 1.1). Fig 1.1 Pipes feeding Digesters
More informationFlygt Mix-Flush System
Flygt Mix-Flush System Model 4901 Issued: 6/94 12/91 The Flygt Mix-Flush (TM) System automatically flushes the sump during initial operation of the pump. The system consists of the Flygt 4901 Flush Valve,
More informationGrit chambers are basin to remove the inorganic particles to prevent damage to the pumps, and to prevent their accumulation in sludge digestors.
Home Lecture Quiz Design Example Grit Chambers Types of Grit Chambers Aerated Grit Chamber Principle of Working of Grit Chamber Design of Grit Chambers Primary Sedimentation Grit Chambers Grit chambers
More informationevoguard The valve series for aseptic applications
The valve series for aseptic applications Safety first Microbiologically sensitive products need to be treated with special care. The highest safety along the entire product handling chain is needed to
More informationWastewater combination air valve in stainless steel AISI 316 Mod. SCS
Wastewater combination air valve in Mod. SCS The air valve guarantees the proper operation of sewage/industrial lines allowing the entrance of large quantity of air in case of pipe bursting or draining,
More informationMITIGATING PIPE AND RISER HYDRAULIC PIPELINE ISSUES WITH THE I-RISER PLUS
24 TH July 2013 MITIGATING PIPE AND RISER HYDRAULIC PIPELINE ISSUES WITH THE I-RISER PLUS Vern Costelow Business Development Consultant AWMA Water Control Solutions INTRODUCTION Surface irrigation is still
More informationCombination Air Valve Model
Combination Air Valve Model Model C10 /C11 Installation, Operation and Maintenance Manual (IOM) Table of Contents General...Page 2 Safety...Page 2 Operational Data...Page 3 Materials and Connections...Page
More informationModel DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.
Bulletin 335 Model DDX-LP Dry Pipe Valve System 8 (200mm) Bulletin 335 Features 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Differential latching clapper-type, lighweight, dependable construction. Low Air Pressurized
More informationDesign. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle
SB Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing A family of API liquid ring compressors has been developed and has been in the market for nearly a decade, they are specifically made
More informationP-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints
Guideline No.P-04 (201510) P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints Issued date: 20 th October 2015 China Classification Society Foreword This Guideline is a part of CCS
More informationCSO/STORMWATER MANAGEMENT. HYDROVEX HHV-E Vortex Driven Regulator
CSO/STORMWATER MANAGEMENT HYDROVEX HHV-E Vortex Driven Regulator HYDROVEX HHV-E VORTEX DRIVEN REGULATOR APPLICATION The hydro electronic HYDROVEX HHV driven regulator, type E is specially designed for
More informationKBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions
4059051/3 IM-P405-48 EMM Issue 3 KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.
More informationAcornVac Vacuum Plumbing Systems - Trouble Shooting Guide
AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide 1. Accumulators Problem Accumulator is overflowing If Accumulator continues to overflow Correction 1. Push and hold the manual activation button
More informationOPERATION MANUAL NTF-15
OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE
More informationTubes Components Valves Units Engineering SO EVERYTHING KEEPS FLOWING. Safety valves Bunging valves Vacuum valves Tank dome fittings
SO EVERYTHING KEEPS FLOWING Safety valves Bunging valves Vacuum valves Tank dome fittings Reliable reaction at the right moment Safety components are part of our everyday life. Like anti-skid systems in
More informationCO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype
(R744) Service Station Presentation Contents Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype Page 1 (R744) Service Station Goals Usability Full automatic
More informationData Sheet Issue A
Features 1. Differential latching clappertype, lighweight, dependable construction. 2. Low Air Pressurized System, 8 psi -to- 26 psi (0,6 bar to- 1,8 bar) 3. Reset externally. Cover removal is not required.
More informationDevelopments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry
Developments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry Franz Trieb, Reinhard Karl, Rene Moderer Bohler Hochdrucktechnik GmbH Kapfenberg, Austria www.bhdt.at
More informationSiting and Installation Manual
Siting and Installation Manual B-Series Advanced Wastewater Treatment Units Revolutionary Waste Treatment Advanced Wastewater Treatment Units (ATUs) that deliver an unsurpassed performance at an unbeatable
More informationSelf-operated Regulators Accessories Differential Pressure and Flow Regulators
Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application
More informationPressure Equipment Directive (PED) 97/23/EC Page 033 of 124
Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124 13.7 Pressure Equipment Directive (PED) 97/23/EC 1 The Pressure Equipment Directive (PED) 97/23/EC applies to the design, manufacturing and conformity
More informationLaboratory Mortar Mixer (Testing)
TomTom-Tools GmbH Zelgli 20 8905 Arni info@tomtom-tools.com Switzerland www.tomtom-tools.com User Manual Version February 22, 2015 Laboratory Mortar Mixer (Testing) 1 Introduction The Laboratory Mortar
More informationKBV21i and KBV40i Air Actuated Boiler Blowdown Valves
4059051/1 IM-P405-48 AB Issue 1 KBV21i and KBV40i Air Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
More informationL21S/SR/ST Glass Level Gauges
L21S/SR/ST Glass Level Gauges Doc. no.: 150, en_cat_l21s/sr/st, 12/2014 Type of code Example: L21ST/1450/AANSI 3/4 150Lb RF/Large chamber Code 1 Basic type L21 2 Type of gauge S Tubular level gauge SR
More informationSMART Explosion. Efficient Boiler Cleaning with Explosion Generators
SMART Explosion Efficient Boiler Cleaning with Explosion Generators Problem and Solution The use of solid fuels, such as coal, waste or biomass, is liable to intense fouling of the steam generator heating
More informationOPERATION MANUAL NTF-60 Plus
OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)
More informationTEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125
TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125 Model: VC-40-VYC Table of contents 1. - Installing the test bench 1.1.1- Connecting the compressed air / nitrogen source 1.1.2- Maximum test pressure according
More informationModule 15 : Grit Chamber. Lecture 20 : Grit Chamber
1 P age Module 15 : Grit Chamber Lecture 20 : Grit Chamber 2 P age 15.6 Square Grit Chamber The horizontal flow rectangular grit chamber faces the problem of sedimentation of organic matter along with
More informationManual Actuated Boiler Blowdown Valves
Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety
More informationFeatures. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes
Bulletin 357 Rev. E Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes Bulletin 357 Rev. E Features 1. 2. 3. 4. 5. 6. 7. 8. 9. Differential-type valve, lightweight, dependable construction.
More informationTECHNICAL DATA. Q = C v P S
Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationOWNER S TECHNICAL MANUAL
EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,
More informationMounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2
Self-operated Pressure Regulator Pressure Reducing Valve Type M 44-2 Type M 44-2, connection G 1 4, K VS = 0.15 Type M 44-2, connection G 1, K VS = 6 Fig. 1 Type M 44-2 Pressure Reducing Valve Mounting
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 9 ACCUMULATORS The material needed for outcome 2 is very extensive so there are
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete
More informationDF1 and DF2 Diffusers
1550650/4 IM-P155-07 ST Issue 4 and Diffusers Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Operation 6. Maintenance
More informationSpirax Compact FREME Flash Recovery Energy Management Equipment
IM-UK-cFREME UK Issue 1 Spirax Compact FREME Flash Recovery Energy Management Equipment Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.
More informationROTAMAT Rotary Drum Fine Screen Ro 2 / RPPS
WASTE WATER Solutions ROTAMAT Rotary Drum Fine Screen Ro 2 / RPPS Reliable and well-proven inlet screen for municipal sewage treatment plants and industrial wastewater and process water screening with
More informationMaintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry
Maintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry Article Takeaways: Chris Doerschlag President ALB Klein Technology Group www.albkleinco.com 1. Troubleshooting Guide
More informationANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS
Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This
More informationOverview. VARICOVER product recovery systems. Special features. Recover the value, reduce the waste! Design with no dead-zones.
Overview Recover the value, reduce the waste! Special features Design with no dead-zones CIP/SIP-able Reduced product loss Reduced cleaning media and water consumption Reduced waste water load Reduced
More informationVORTEX REGULATOR Type WAB (UCY / CY-F / CE/V)
VORTEX REGULATOR Type WAB (UCY / CY-F / CE/V) UCY series, CY series, CE/V series, OP series Conical vortex regulator Type WAB-UCY (wet installation) Vertical vortex regulator Type WAB- CE/V (wet installation)
More informationBT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications
1800350/6 IM-P180-12 ST Issue 6 BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications Installation and Maintenance Instructions 1. Safety information 2. General
More informationMST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap
1250650/6 IM-P125-07 ST Issue 6 MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation
More informationMFP14-PPU (Vented) Automatic Packaged Pump Units
681060/2 IM-P681-02 ST Issue 2 MFP14-PPU (ented) Automatic Packaged Pump Units Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Single MFP14 - PPU installation
More informationInert Air (N2) Systems Manual
INSTRUCTION MANUAL Inert Air (N2) Systems Manual N2-MANUAL 2.10 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. GENERAL INFORMATION Positive pressure nitrogen gas pressurizing
More informationHANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:
HANDBOOK Squeeze Off Unit SOU 400 Please refer any queries to: Hy Ram Engineering Co Ltd Pelham Street Mansfield Nottinghamshire NG18 2EY Telephone No: (01623) 422982 Please note all queries should state
More informationThe Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times
Tseries Series AB AB Air Air Boosters Boosters The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times.01/1 MANIFOLD MOUNTED VALVES FOR EASY SERVICING
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS ALPHATREAT DP10 WASTEWATER TREATMENT SYSTEM A. PREPARING THE SITE INSTALLATION SUGGESTIONS See if you can site the tanks away from commonly used vehicular access, and also away
More informationDAV - P. Product Catalogue DAV - P. Air release & Vacuum Break Valves. (Plastic Air Valves) DAV - P. Edition 2012
Product Catalogue DAV - P DAV - P Air release & Vacuum Break Valves Edition 1 DAV - P (Plastic Air Valves) DAV Series Overview General The presence of trapped air in a pressurized pipeline can have serious
More informationUSER MANUAL. 1. Principle of operation. 2. Delivery condition. SPRING-LOADED SAFETY VALVES zarmak. Edition: 07/2016 Date: V (ex.
ZETKAMA Sp. z o.o. ul. 3 Maja 12 PL 57-410 Ścinawka Średnia SPRING-LOADED SAFETY VALVES zarmak USER MANUAL 782V (ex. 782) Edition: 07/2016 Date: 01.07.2016 TABLE OF CONTENTS 1. Principle of operation 2.
More informationDesign a grit chamber for population with water consumption of 135 LPCD.
1 Example:1 Design a grit chamber for population 50000 with water consumption of 135 LPCD. Solution Average quantity of sewage, considering sewage generation 80% of water supply, is = 135 x 50000 x 0.8
More informationCP10 Sensor Installation and Maintenance Instructions
4030150/9 IM-P403-26 EMM Issue 9 CP10 Sensor Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Maintenance 5. Spare parts Copyright 2017
More informationTECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY
Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationPressure on Demand. Air Pressure Amplifiers
Pressure on Demand Air Pressure Amplifiers Introduction Haskel air pressure amplifiers offer the most comprehensive range in the industry combining simple principles of operation with rugged construction
More information13. Evaporative Emission Control System
EG-62 ENGINE 3MZ-FE ENGINE 13. Evaporative Emission Control System General The construction of the evaporative emission control system has been changed to comply with the LEV-II (Low Emission Vehicle-II)
More informationTECHNICAL DATA. Q= Cv S
Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationSOME TECHNICAL AND PRACTICAL RECOMMENDATIONS ABOUT PULSATION DAMPENERS IN CIRCUITS WITH DOSING OR VOLUMETRIC PUMPS
1 SOME TECHNICAL AND PRACTICAL RECOMMENDATIONS ABOUT PULSATION DAMPENERS IN CIRCUITS WITH DOSING OR VOLUMETRIC PUMPS DESCRIPTION OF A PULSATION DAMPENER AND HOW IT WORKS A pulsation dampener is a vessel
More informationTECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13
Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationSV60 Safety valves. for use with steam, gas and liquids
SV60 Safety valves for use with steam, gas and liquids Spirax Sarco safety valves - protecting people, plant and profit The SV60 spring loaded full lift safety valve range from Spirax Sarco has been designed
More informationTECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.
Page 1 of 8 1. DESCRIPTION A Viking Pilot Pressure Regulated Deluge System utilizes a Viking Flow Control Valve to control water flow into the deluge system. The flow control valve must be installed with
More informationINDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS
IBAIONDO, HYDROPNEUMATIC TANKS IBAIONDO, INTRODUCTION Hydropneumatic tanks are designed to be used in potable water supply installations as a part of the pressure booster set in order to ensure the adequate
More informationJOS 15 JOS 25 JOS 40. Manual and semiautomatic test benches from DN 25 to DN 40. Characteristics. Basic characteristics. Test bench using balances
TEST BENCHES JOS 15 JOS 25 JOS 40 Manual and semiautomatic test benches from DN 25 to DN 40 02 Characteristics Compact test benches - all in one room Designation - for residential and apartment meters
More informationIr HN Lam BSc(Eng), MSc(Eng), CEng, MIMechE, MCIBSE, MASHRAE, MASME, MHKIE. Test Report on Non-Return Valve for Water Closets
c/o Department of Mechanical Engineering University of Hong Kong Pokfulam Road Hong Kong Phone: 28592640 E-mail: hn.lam.hku@hku.hk Ir HN Lam BSc(Eng), MSc(Eng), CEng, MIMechE, MCIBSE, MASHRAE, MASME, MHKIE
More informationGENO -Flushing Compressor Product Data Sheet F 02
GENO -flushing compressor 1988 K Fig. 1: GENO -flushing compressor 1988 K Designated application is suitable for the following fields of application: Flushing of pipes with water/air mix prior to the start-up
More informationCVS10 Sanitary Check Valves
0299050/4 IM-P029-11 ST Issue 4 CVS10 Sanitary Check Valves Installation and Maintenance Instructions 1. Safety information CVS10 with soft seat 2. General product information 3. Operation 4. Installation
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationSKAC25 Operate plant to maintain the quality of pool water
Overview This unit is about operating swimming pool plant. The unit covers start-up and shut-down, routine maintenance and ensuring that the water quality, clarity and temperature are safe and within the
More informationFITTINGS AND VALVES Düker Plunger Valve RKV Type 7015 Professional control of flow rates, reservoir levels and pressures Safe, hygienic and durable!
FITTINGS AND VALVES Düker Plunger Valve RKV Type 7015 Professional control of flow rates, reservoir levels and pressures Safe, hygienic and durable! 1 The New Düker Plunger Valve Type 7015 St Plunger valves
More informationBall Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"
Data Sheet 819584-00 Issue Date: 01/17 Ball Float Steam Trap UNA 43 PN 16/C 125/JIS 10K UNA 46 PN 40/C 150/C 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6" UNA 43 hl, UNA 46 hl UNA 43 v, UNA 46 v with
More informationOffshore Equipment. Yutaek Seo
Offshore Equipment Yutaek Seo Flash Gas Compressor (East spar) Dehydration NGL recovery Slug catcher Separator Stabilization Booster compressor Gas export compression (Donghae-1 Platform) May 7 th Gas
More informationSizing Pulsation Dampeners Is Critical to Effectiveness
Sizing Pulsation Dampeners Is Critical to Effectiveness Pressure variation is an important consideration when determining the appropriate size pulsation dampener needed for an application. by David McComb,
More informationTW Temperature Control Valve
0470050/6 IM-P047-04 CH Issue 6 TW Temperature Control Valve Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Maintenance 5. Spare parts
More informationClassic wine storage tanks model EXX
Classic wine storage tanks model EXX Model EXX storage tank is a classic type E tank, without a double jacket. They are designed for storing wine under atmospheric pressure. They are characterized by top-quality
More informationApplied Fluid Mechanics
Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and
More informationPUBLIC COMPANY ORLEN LIETUVA OCCUPATIONAL HEALTH AND SAFETY PROCEDURE BDS-12 USE OF PORTABLE GAS ANALYZERS I. GENERAL
PUBLIC COMPANY ORLEN LIETUVA APPROVED BY Deputy Director of Quality, Labor Safety and Environmental Control Director 30 November 2017 Order No TV1(1.2-1)-457 OCCUPATIONAL HEALTH AND SAFETY PROCEDURE BDS-12
More informationFLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:
FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed for outcome
More informationKnife Gate Valves Pricelist 2017
Knife Gate Valves list 2017 Range of Knife Gate Valves * Manual and Actuated Knife Gate Valves * Accessories * Stafsjo Knife Gate Valves Knife Gate Valves list 2017 About Us All Valves Online Ltd are a
More informationProduct Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12
Product Information Three in One: Gas Meter Tariff Device Volume Corrector Ultrasonic Gas Meter ECOSONIC X12 ECOSONIC X12 Values you can count on The Application Fields The ultrasonic gas meters of the
More informationProject Title: Pneumatic Exercise Machine
EEL 4924 Electrical Engineering Design (Senior Design) Preliminary Design Report 27 January 2011 Project Title: Pneumatic Exercise Machine Team Members: Name: Gino Tozzi Name: Seok Hyun (John) Yun Email:
More informationOrifice Plate Flow Meter
Orifice Plate Flow Meter FOFT Measuring Principle The principle of measuring the differential pressure is based on the fact that a differential pressure is created across that section of a pipe where its
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated
More informationDN300 DN2000 C Plunger Valve
ל DN300 DN2000 C Plunger Valve P.O.B 46 MOSHAV SHTULA WESTERN GALILEE 2286500 Tl. +972-(0)77-6656101, Fax. +972-(0)77-6656196 Website: www.saisanketvalves.com www.saisanket.com email: saisanket@saisanket.com
More information"INOGATE Technical Secretariat & Integrated Programme in support of the Baku Initiative and the Eastern Partnership energy objectives" Project
"INOGATE Technical Secretariat & Integrated Programme in support of the Baku Initiative and the Eastern Partnership energy objectives" Project B U I L D I N G P A R T N E R S H I P S F O R E N E R G Y
More informationHUBER Rotary Drum Fine Screen ROTAMAT Ro2 / RPPS / STAR
WASTE WATER Solutions HUBER Rotary Drum Fine Screen ROTAMAT Ro2 / RPPS / STAR Reliable and well-proven inlet screen for municipal sewage treatment plants and industrial wastewater and process water screening
More informationArmatures for analytical probes
Armatures for analytical probes For many different types of installations and applications Large range of probe holders General purpose, water treatment, food & beverage, pharmaceutical applications Type
More informationTD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats
0686550/4 IM-P068-58 ST Issue 4 TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation
More informationHYDROVEX TTT Membrane Flow Regulator
HYDROVEX TTT Membrane Flow Regulator INSTALLATION, OPERATION AND MAINTENANCE MANUAL PROJECT EQUIPMENT LOCATION EQUIPMENT DESCRIPTION HYDROVEX TTT REFERENCE N OF THE SUPPLIER MODEL N SERIAL N DATE OF FABRICATION
More informationThe affordable consumption counter for compressed air and gases R 3 /4 (DN 20)
VA 420 new The affordable consumption counter for compressed air and gases R 1 /4 (DN 8) DN 15 R 3 /4 (DN 20) DN 25 R 1 1 /4 (DN 32) DN 40 R 2 (DN 50) With mit und and ohne without Flansch flange Intelligent
More informationTDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions
1870050/7 IM-P187-05 CMGT Issue 7 TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions TDC46M and TDS46M UTDS46M 1. Safety information 2.
More informationM-06 Nitrogen Generator (Nitrogen Making Machine)
Guideline No.M-06 (201510) M-06 Nitrogen Generator (Nitrogen Making Machine) Issued date: 20 th October, 2015 China Classification Society Foreword This Guideline is a part of CCS Rules, which contains
More informationPressure Calibrators. Series PC..., PM...
Pressure Calibrators Series PC..., PM... SIKA-Precision Pressure Calibrators, Series PC..., PM... We help you, if you are under pressure! Pneumatic pressure calibrators PM 25 A, PM 25 D, PM 110 PIC pressure
More informationTP1 and TP2 Temporary Cone Shaped Strainers
1698051/2 IM-P169-07 ST Issue 2 TP1 and TP2 Temporary Cone Shaped Strainers Installation and Maintenance Instructions TP1 1. Safety information 2. General product information 3. Installation and commissioning
More informationCERTIFYING DRAINLAYER
No. 9198 REGISTRATION EXAMINATION, NOVEMBER 2017 CERTIFYING DRAINLAYER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2017. All rights reserved. No part of this publication may be reproduced
More informationData Sheet Issue A
Features 1. Differential-type valve, lightweight, dependable construction. 2. Low Air Pressurized System, 10 psi -to- 26 psi (0,7 bar -to- 1,8 bar). 3. Reset externally.cover removal is not required. 4.
More information