Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN
|
|
- Rafe Garrett
- 6 years ago
- Views:
Transcription
1 Floodlight LED Operating instructions Additional languages
2 Contents 1 General Information Manufacturer Information regarding the operating instructions Conformity with standards and regulations Explanation of the symbols Symbols in these operating instructions Warning notes Symbols on the device Safety notes Operating instructions storage Safe use Intended Use Modifications and alterations Function and device design Function Device design Technical data Transport and storage Mounting and installation Dimensions / fastening dimensions Mounting / dismounting, operating position Installation Commissioning Maintenance, Overhaul, Repair Maintenance Repair Returning the device Disposal Accessories and Spare parts Floodlight LED
3 1 General Information 1.1 Manufacturer R. Stahl Schaltgeräte GmbH Am Bahnhof Waldenburg Germany Phone: Fax: Internet: Information regarding the operating instructions ID-No.: Publication Code: The original instructions are the English edition. They are legally binding in all legal affairs. General Information R. STAHL (P) LTD., Plot No. - 5 Malrosapuram Road, Sengundram Indl. Area Singaperumal Koil, Kancheepuram Dist., Tamil Nadu , INDIA Phone: Fax: Internet: sales@rstahl.net 1.3 Conformity with standards and regulations See certificates and EU Declaration of Conformity: The device has IECEx approval. See IECEx homepage: Further national certificates can be downloaded via the following link: Floodlight LED 3
4 Explanation of the symbols 2 Explanation of the symbols 2.1 Symbols in these operating instructions Symbol Meaning Tips and recommendations on the use of the device General danger Danger due to explosive atmosphere Danger due to energised parts Risk of damage to the eyes caused by optical radiation 2.2 Warning notes Warnings must be observed under all circumstances, in order to minimize the risk due to construction and operation. The warning notes have the following structure: Signalling word:, WARNING, CAUTION, NOTICE Type and source of danger/damage Consequences of danger Taking countermeasures to avoid the danger or damage Danger to persons Non-compliance with the instruction results in severe or fatal injuries to persons. WARNING Danger to persons Non-compliance with the instruction can result in severe or fatal injuries to persons. CAUTION Danger to persons Non-compliance with the instruction can result in light injuries to persons. 4 Floodlight LED
5 Safety notes 2.3 Symbols on the device 3 Safety notes NOTICE Avoiding material damage Non-compliance with the instruction can result in material damage to the device and / or its environment. Symbol 05594E E00 Meaning CE marking according to the currently applicable directive. According to marking, device approved for hazardous areas. 3.1 Operating instructions storage Read the operating instructions carefully. Store the operating instructions at the mounting location of the device. Observe applicable documents and operating instructions of the devices to be connected. 3.2 Safe use Read and observe the safety notes in these operating instructions! Observe characteristic values and rated operating conditions on the rating and data plates! Observe additional information plates on the device! Use the device in accordance with its intended and approved purpose only! We cannot be held liable for damage caused by incorrect or unauthorized use or by non-compliance with these operating instructions. Before installation and commissioning, make sure that the device is not damaged! Work on the device (installation, maintenance, overhaul, repair) may only be carried out by appropriately authorized and trained personnel. 3.3 Intended Use The LED floodlight 6525 is equipment for stationary mounting for use in Zones 21, 2, 22 and in the safe area can be used indoors and outdoors for lighting areas, work spaces and objects 3.4 Modifications and alterations Explosion hazard due to modifications and alterations to the device! Non-compliance results in severe or fatal injuries. Do not modify or alter the device. Floodlight LED 5
6 Function and device design 4 Function and device design 4.1 Function for lighting areas, work spaces and objects 4.2 Device design Explosion hazard due to improper use! Non-compliance results in severe or fatal injuries. Use the device only in accordance with the operating conditions described in these operating instructions. Use the device only for the intended purpose specified in these operating instructions E Mounting bracket 8 - Seal 2 - Enclosure cover 9 - Luminaire glass cover 3 - Retaining bracket LED-Driver 10 - Mounting screws 4 - LED-Driver LED-Driver 2 (only for 210 W version) 5 - LEDs 12 - Cable glands 6 - Luminaire enclosure 13 - Connection terminal 7 - Heat sink (only for 210 W version) 6 Floodlight LED
7 5 Technical data Explosion Protection Global (IECEx) Gas and dust IECEx EPS Ex nr op is IIC T6... T5 Gc Ex tb IIIC T80 C... T95 C Db Europe (ATEX) Gas and dust EPS 15 ATEX E II 3 G Ex nr op is IIC T6... T5 Gc E II 2D Ex tb IIIC T80 C... T95 C Db Certifications and certificates Certificates IECEx, ATEX, India (PESO) Technical Data Electrical data Electronic balast Rated voltage Rated current 6525/ / AC: V ±10 %; Hz Technical data Power Ambient temperature Max. surface temperature 120 W 210 W ( +60 C T5 / T95 C 6525/ W ( +50 C T6 / T80 C 6525/ W ( +45 C T6 / T80 C Ambient temperature Power C C 120 W 0.60 A 0.54 A 210 W 1.00 A 0.94 A Inrush current 120 W Version 210 W Version I peak (measured at 50 % I peak ) 62 A; ãt = 330 ms 124 A; ãt = 330 ms max. light fittings per circuit breaker Type B Type C Type B Type C 10 A A A A Power factor > 0.95 THD ( 10 % Floodlight LED 7
8 Technical data Technical Data Luminous characteristics Luminous flux decrease 6525/ / Power consumption [W] Colour rendering [CRI] ) 70 ) 70 Colour temperature [K] 5,700 5,700 wide beam Luminous flux [lm] 12,860 21,026 Luminous efficiency [lm/w] medium beam Luminous flux [lm] 12,669 20,966 Luminous efficiency [lm/w] narrow beam Luminous flux [lm] 12,081 19,979 Luminous efficiency [lm/w] Values apply to T a = +25 C. at ambient temperature 115 % 100 % 85 % 70 % 55 % 210 W Version 120 W Version 40 % 25 % 30 C 35 C 40 C 45 C 50 C 55 C 60 C Ambient conditions Operating temperature range C * * Note: Possible to operate the luminaire at -60 C, provided the luminaire is switched on at -40 C. Delay of 10 seconds below -40 C during cold start Storage temperature C 19597E00 8 Floodlight LED
9 Technical Data Service life Mechanical data Degree of protection Protection class Impact strength (IK code) Material Enclosure IP66 I (with internal PE connection) IK10 (IEC 62262) Ambient temperature T a Colour Colour white, similar to RAL 9010 Seal Foamed silicone in luminaire cover Lamp cover Toughened glass Bracket Sheet steel, single powder-coated or Stainless steel SS316L ( or V4A) without powder coating Luminaire locking Screw Mounting / Installation Cable entry 1x cable glands Series x cable glands Series 8161 with red stopping plug 1x stopping plugs Series 8290 Connection Standard: Spring clamp terminals mm 2 solid / stranded Stripping length: mm Optional: Spring clamp terminals mm 2 solid / stranded Stripping length: mm Technical data ( +40 C +45 C +50 C +55 C +60 C L 70 B 10 C ,000 h 80,000 h 80,000 h 60,000 h 50,000 h L x B y C z At the end of the service life: - Luminous flux decreases by x percent. - up to "y" percent of all luminaires fall below "x" - up to "z" percent of all luminaires break down completely 6525/ Sheet steel, powder-coated 6525/ Stainless steel SS316L ( or V4A), with double powder coating (offshore coating) Loop in/loop out max. 12 A Alternative material: Enclosure: stainless steel SS304 ( or V2A) single powder-coated stainless steel SS316L ( or V4A) without powder coating Bracket: stainless steel SS304 ( or V2A) without powder-coated Floodlight LED 9
10 Transport and storage 6 Transport and storage Transport and store the device only in the original packaging. Store the device in a dry place (no condensation) and vibration-free. Do not drop the device. 7 Mounting and installation Explosion hazard due to incorrect installation of the device! Non-compliance results in severe or fatal injuries. Carry out installation strictly according to the instructions and national safety and accident prevention regulations to maintain the explosion protection. Select and install the electrical device so that explosion protection is not affected due to external influences, i.e. pressure conditions, chemical, mechanical, thermal and electric impact such as vibration, humidity and corrosion (see IEC/ ). The device must only be installed by trained qualified personnel who is familiar with the relevant standards. 7.1 Dimensions / fastening dimensions Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 400 [ 15,75] 600 [ 23,62 ] 131,90 [ 5,19] 400 [ 15,75] 89,50 [ 3,52] 600 [ 23,62 ] 89,50 [ 3,52] 17560E00 Floodlight with cooling element (Version 210 W) 17559E00 Floodlight without cooling element (Version 120 W) 10 Floodlight LED
11 Mounting bracket 18258E00 Mounting and installation Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 363 [1,38] 3 [0,12] 445 [17,52] 405 [15,94] R 20 [R 0,79] 250[9,84] 3 x Ø13 [3 x Ø 0,51] 20 [0,79] Floodlight with ring bolts with cooling element (Version 210 W) 380 [14,96] 60 [2,36] 363 [14,29] 13 x Ø8,50 [13 x Ø 0,33] Ø 8,50 [Ø 0,33] Floodlight with ring bolts without cooling element (Version 120 W) 17561E EE00 Floodlight LED 11
12 Mounting and installation 7.2 Mounting / dismounting, operating position Explosion hazard due to inadmissible heating! Non-compliance results in severe or fatal injuries. Avoid external heat sources and/or direct sunlight (risk of change of temperature class or change of maximum permissible surface temperature). Do not exceed the maximum ambient temperature due to external heat sources (premature failure of equipment). CAUTION Risk of damage to the eyes caused by optical radiation! Minor injuries are possible! The minimum distance for the narrow beam version between the luminaire and the viewer's eyes must be 8.23 m. suitable for use indoors and outdoors designed for wall, ceiling, pole mounting with bracket max torque value between bracket and floodlight 10 Nm pendant mounting using ring eyes (M6). 7.3 Installation Opening and Closing of the Enclosure Risk of electric shock due to improper opening! Non-compliance results in severe or fatal injuries. Open luminaires without switch only in de-energized state (see information plate on the lock)! NOTICE Danger due to electrostatic discharge. Electronic components can be destroyed if touched. Do not touch the LED-PCBs! 12 Floodlight LED
13 Opening the luminaire (1) loosen the four mounting screws. (2) carefully open the enclosure cover. (3) open the enclosure cover fully. Mounting and installation 18669E00 Closing the luminaire (4) liften the enclosure cover. (5) carefully close the enclosure cover. (6) securely tighten the four screws (torque value 5 Nm) E00 Floodlight LED 13
14 Mounting and installation Cable entries WARNING Not approved cable glands and stopping plugs. Explosion protection is impaired! Only use separately certified cable glands and stopping plugs. Cable glands and stopping plugs must be approved for the following types of protection: a) restricted breathing (nr) and dust (IIIC) b) increased safety (e) Recommendation: Use of cable glands and stopping plugs supplied by R. STAHL Schaltgeräte GmbH. see data sheet on our homepage Please observe the following, if cable glands and stopping plugs are used, but not provided by R. STAHL Schaltgeräte GmbH: Permissible cable diameter range, torques, temperature range of use IP level of protection, at least IP 65 or according to details on rating plate Operating instructions of the cable glands and stopping plugs additionally, observe the following for cable glands and stopping plugs of the type of protection "increased safety" (e): valid EC type examination certificate and confirmation of the manufacturer for the combination of the cable and screw connection Explosion hazard if breathers are used! Accidents or fatal injury are almost certain to happen! Do not use breathers. 14 Floodlight LED
15 7.3.3 Electrical connections Electrical connection Observe the maximum clamping possibility of the connecting terminals (see chapter "Technical data"). Note: Clamping must be carried out precisely! Do not clamp any part of the conductor insulation! Do not interchange the conductors! Observe the technical regulations when connecting the conductor! Clamp the conductor firmly. Connection terminals Standard: Spring clamp terminals 0.5 to 4 mm 2 (rigid and flexible) Stripping length: mm 5-pole N L1 L2 L3 N L1 L2 L E00 Legend L1, L2, L3 = phase (3-pole: L1; 5-pole: L1, L2, L3) N = neutral conductor PE = protective conductor Mounting and installation Optional: Spring clamp terminals 0.5 to 6 mm 2 (rigid and flexible) Stripping length: mm 5-pole 16526E00 Floodlight LED 15
16 Commissioning 8 Commissioning Explosion hazard due to incorrect installation! Non-compliance results in severe or fatal injuries. Check the device for proper installation before commissioning. Comply with national regulations. Explosion hazard due to incorrect installation! Non-compliance results in severe or fatal injuries. Carry out the restricted breathing test prior to first commissioning. (See chapter "Restricted breathing test") Before commissioning, ensure the following: Check the mounting and installation. Inspect enclosure for damage. If necessary, remove foreign bodies. If necessary, clean the connection chamber. Check if the conductors have been inserted correctly. Check if all screws and nuts have been tightened firmly. Check whether all the cable entries and stopping plugs have been tightened firmly. Check if all conductors have been clamped firmly. Check if the line voltage and the rated operational voltage are consistent. Check if the permissible conductor diameter for the corresponding cable entries have been used. Check if the device is closed according to regulations. Check whether the bracket mounting & cover mounting screws are tightened with proper torque. NOTICE Malfunction or device damage caused by condensation. Non-compliance can result in material damage! operate the luminaire continuously or periodically over extended periods of time. avoid thermal bridges. 16 Floodlight LED
17 9 Maintenance, Overhaul, Repair 9.1 Maintenance Maintenance, Overhaul, Repair WARNING Risk of electric shock or malfunctioning of the device due to unauthorized work! Non-compliance can result in severe injuries and material damage. Work performed on the device must only be carried out by appropriately authorized and qualified electricians. To be carried out as per and as per Explosion hazard due to hot built-in components! Accidents or fatal injury are almost certain to happen! Only open the enclosure in switched-off state. The device must be allowed to cool down for at least 15 minutes before opening it. NOTICE Danger due to electrostatic discharge. Electronic components can be destroyed if touched. Do not touch the LED-PCBs! Observe the relevant national regulations in the country of use. Determine the type and extent of inspections in compliance with the relevant national regulations. Adapt inspection intervals to the operating conditions. The following tests and measures must be carried out during regular maintenance. Check the permissible ambient temperature the enclosure components for formation of cracks and damage. its intended use if the conductors are clamped properly the cables for ageing and damage Measures If exceeding the permissible ambient temperature or falling below the device must be taken out of operation. Replace the exchangeable enclosure components. If the enclosure components are non-exchangeable, the device must be taken out of operation. If the device is not used according to its intended use, it must be taken out of operation. clamp loose conductors tightly. replace damaged or aged cables. Floodlight LED 17
18 Maintenance, Overhaul, Repair Check the seals for ageing and damage Measures replace damaged, aged and porous seals and completely change enclosure components with foamed seal. the inside and outside of the luminaire for clean the luminaire. pollution Restricted breathing of enclosure (see chapter "Restricted breathing test"). If the restricted breathing test has failed, take the device out of operation! NOTICE Moisture inside the light fitting can result in damage to electric and electronic components. Remove moisture with a cloth! Determine the source and eliminate the cause! Avoid condensation and thermal bridges! WARNING Restricted breathing is not guaranteed any longer! Explosion protection is impaired! After replacing seals or enclosure components carry out the restricted breathing test acc. to IEC/ , para Restricted breathing test The luminaire is equipped with a test device for restricted breathing. Restricted breathing must be checked after installation and during regular maintenance acc. to IEC/ Inspection according to IEC/ , para Recommendation Check the luminaire by using the handheld testing instrument for restricted breathing from R. Stahl Schaltgeräte GmbH (see data sheet). The test should only be carried out at constant temperature conditions. 18 Floodlight LED
19 Maintenance, Overhaul, Repair In order to test restricted breathing (pressure test), the luminaire is equipped with a cable entry with red stopping plugs. Remove the red stopping plug. Insert the hose of the test device into the cable entry for testing restricted breathing. Hand-tighten the cable entry. Use the hand pump to create a vacuum of 0.3 kpa (3 mbar). The test has been passed if after 90 seconds a vacuum of at least 0.15 kpa (1.5 mbar) is still present in the luminaire. After inspection: Remove the hose of the test device for testing restricted breathing from the cable entry. Close the luminaire using the red stopping plug. Alternative pressure and time specifications: Alternative 1 Alternative 2 Vacuum at start of test 3.0 kpa (30 mbar) 0.3 kpa (3 mbar) Test duration 14 seconds 14 seconds Vacuum after testing 2.7 kpa (27 mbar) 0.27 kpa (2.7 mbar) If the luminaire is only marked with the type of protection for dust (IIIC), the cable entries and stopping plugs do not need to meet the requirements for restricted breathing (nr) Cleaning Clean the device only with a cloth, brush, vacuum cleaner or similar items. When cleaning with a damp cloth, use water or mild, non-abrasive, non-scratching cleaning agents. Do not use aggressive detergents or solvents. 9.2 Repair Explosion hazard due to improper repair! Non-compliance results in severe or fatal injuries. Repair work on the devices must be performed only by R. STAHL Schaltgeräte GmbH. 9.3 Returning the device Use the "Service form" to return the device if repair or service is required. On the internet site " under "Downloads > Customer service": Download the service form. Fill out the service form. Send the device along with the service form in the original packaging to R. STAHL Schaltgeräte GmbH. Floodlight LED 19
20 Disposal 10 Disposal Observe national and local regulations and statutory regulation regarding disposal. Separate materials when sending it for recycling. Ensure environmentally friendly disposal of all components according to the statutory regulations. 11 Accessories and Spare parts NOTICE Malfunction or damage to the device due to the use of non-original components. Non-compliance can result in material damage. Use only original accessories and spare parts from R. STAHL Schaltgeräte GmbH. For accessories and spare parts, see data sheet on our homepage 20 Floodlight LED
21
Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN
Floodlight LED Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding the operating instructions...3
More informationOperating Instructions
Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table
More informationOperating Instructions
Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2
More informationOperating Instructions
LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.
More informationE10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.
> Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to
More informationArran LED Floodlight Luminaire
Arran LED Floodlight Luminaire INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this equipment. Good electrical
More informationFurther technical information is available on
1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,
More informationPull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS
Pull-rope emergency stop switch Type OPERATING INSTRUCTIONS Legal Notice (Translation of the original) Document No.: 94.058 816.191 Pull-rope emergency stop switch, Type HENEX and SEGEX Product number:
More informationVS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions
VS18/26 with PROFINET and EtherNet/IP Interface ATEX Installation Instructions INDEX 1. INTENDED USAGE 3 2. OPERATING MANUAL ATEX 4 2.1 General conditions 4 2.2 Installation 5 2.3 Operating 5 2.4 Failures
More informationType Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.
2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques.
More informationLTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.
LTB013EN Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. to IECEx scheme Subject to technical modification Bachofen AG Ackerstrasse 42
More information3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.
3G Operating instructions Type: 03-5110-00.. Document no.: 03-5110-7D0001 Version: 01. July 2011/Rev. 0 Operating Instructions Type: 03-5110-00.. Document no.: 03-5110-7D0001 Version: 1 July 2011 / Rev.
More informationType BBS-03, BBS-05, BBS-06, BBS-25
Type BBS-03, BBS-05, BBS-06, BBS-25 Sterile connection elements Sterile Verbindungselemente Raccords union stériles Operating Instructions Bedienungsanleitung Manuel d utilisation 1. THE OPERATING INSTRUCTIONS
More informationSafety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14
15 Elster GmbH Edition 7.15 Translation from the German 519 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VG VG 15/1 Contents Solenoid valve for gas
More informationMODELS (2 foot Version) (4 foot Version)
INSTALLATION AND MAINTENANCE MANUAL DUROSITE LED LINEAR FIXTURE Document No: 9100-127-2571-99 Rev A April, 2016 MODELS (2 foot Version) (4 foot Version) ALL LAE ALL LBE These instructions contain important
More informationManual Power relay SR853
Manual Power relay SR853 Rev. 0 SR853 manual page2 Safety Guidelines for explosion proof devices Application and Standards This instruction manual applies to explosion protected control systems of protection
More informationType 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation
Type 0404 / 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions
More informationEX-RECESSED CEILING LIGHT FITTINGS
EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic
More information(Certification N:o VTT 08 ATEX 066 or IECEx VTT )
(Certification N:o VTT 08 ATEX 066 or IECEx VTT 12.0009) Thank you for choosing Slam Hornet portable work light for your job site. Purpose of this manual is to provide you all the necessary safety and
More informationActuating elements for ComEx
Description A large number of variants and versions of actuating elements are available for the ComEx control and indicator units. All actuating elements are made of high-quality thermoplastic and conform
More informationMeasurement accessories METPOINT OCV for the measurement in systems up to 40 bar
EN - english Instructions for installation and operation Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar Dear customer, Thank you for deciding in favour of the METPOINT
More informationenclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)
enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) Stainless steel and plastic enclosures for use in potentially explosive environments R Rittal system partners Perfect
More informationOperating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073
Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4
More informationJunction Boxes Series 8118
> Enclosure in glass fibre reinforced polyester resin > 3 different sizes available with 4, 5 or as a junction box with integrated miniature fuse: 3 terminals and 1 miniature fuse 7 terminals and 1 miniature
More informationContents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520
Operating instructions Contents EN Pressure switch, heavy-duty version Model PSM-520 1. General information 2. Design and function 3. Safety 4. Transport, packaging and storage 5. Commissioning, operation
More information* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.
*09005087* DB_BA_EN_ME01_S Rev.A 12/16 *09005087* d e v e l o p i n g s o l u t i o n s Data Sheet and Operating Manual ME01 Digital manometer Table of Contents ME01 ## # 87 # HL S#### Dust explosion protection
More informationOperating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027
Operating Instructions Ball valve fitting according to ZB 2553 For pressure transmitter VEGABAR 82 Document ID: 50027 Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3
More informationATEX, IECEx and MET (Class I, Division 1) Safety Instructions icam502
ATEX, IECEx and MET (Class I, Division 1) Safety Instructions icam502 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
More informationInstruction Manual Contact Pressure Vacuum Gauge
MS10 Instruction Manual Contact Pressure Vacuum Gauge Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance
More informationMagnetic level switch type MR783 Instruction Manual
Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2
More informationOSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide
OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature
More informationCompact differential pressure switch Flameproof enclosure Ex d Models DE, DEC
Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring
More informationNorrsken Family Booklet
Section 1: Introduction Low Energy Designs produce efficient and effective LED based lighting products for commercial, retail and industry purposes. Each product may contain specific details on its operation
More informationenclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)
lri030784900.eps lri031083400.eps enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) fri040466500.eps Stainless steel and plastic enclosures for use in potentially explosive
More informationType 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies
Type 2000 INOX 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies Quickstart English Deutsch Français Contents 1 QUICKSTART... 2 2 CONTACT ADDRESS... 2 3 INTENDED USE...
More informationPORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315
PORTABLE WORK LIGHT MODEL NO: CL6FS PART NO: 4003530 OPERATION INSTRUCTIONS GC0315 INTRODUCTION Thank you for purchasing this CLARKE Worklight. Before attempting to use this product, please read this manual
More informationINSTRUCTION MANUAL Pressure Relief Device LPT
INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF
More informationSafety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14
2 Elster GmbH Edition. Translation from the German 22 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas G / G Contents Solenoid valve for gas G / G....
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 14.0034X Issue No:
More informationLED 14W POLO BULKHEAD WITH MICROWAVE SENSOR
INTRODUCTION The LED 14W POLO Bulkhead is a modern lowcost and energy efficient fitting ideal for domestic and utility applications. SPECIFICATION LED 1150lm IP54 220-240V IK09 4000K 50/ 60Hz >82 Ra 14W
More informationLess power great performances
148 SMART SMART Less power great performances SMART is the answer to the increasing demand for both low energy consumption and high efficiency. Based on many years experience in road lighting, it offers
More informationInstruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor
Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-Mail: info@halstrup-walcher.com
More informationAssembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar)
Assembly instruction 1 2 3 4 5 6 7 1. Entry Component 2. Compound Sleeve 3. Interlocking Armour Cone 4. Armour Clamping Ring 5. Gland Body 6. Outer Sheath Sealing 7. Dome Nut 8. Compound 8 Operating temperature
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation
2/2- and 3/2-way cartridge solenoid valve 2/2- und 3/2-Wege-Cartridge-Magnetventil Électrovanne cartridge à 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the
More informationDigital Melting Point Apparatus
Digital Melting Point Apparatus Heating Plateau Ramping Start/Stop Plateau set Ramp stop Hold User Guide Version 1.1 Heating Viewing tube Sample Chamber IEC power inlet socket Power on/off Temperature
More informationPressure switch KP-E. Data sheet
Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches
More informationOPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26
OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26 Made For: Spitwater Australia Pty Ltd 953 Metry St North Albury, NSW, Australia WARNING: FAILURE TO FOLLOW OPERATING, SAFETY AND MAINTENANCE
More informationPressure Measurement Single-range transmitters for general applications
Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials
More informationDeclaration of Conformity as per Directive 97/23/EC
Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany Multi-way diverting valves Series 29a and Series 29b, with packing with lever 1. The valves are
More informationType /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation
3/2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the right to make technical changes without notice.
More informationOperating Instructions Temperature Measuring System MF420-5T-100
Operating Instructions Temperature Measuring System Dnhqdhnjah MF420-5T-100 Dmsklakla Read before use! Observe all safety instructions! Keep for future reference! Fon +49/7221/64103 Fax +49/7221/17103
More informationOPTIBAR P 1010 C Technical Datasheet
Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability
More informationRocker valve. Type Operating Instructions. Bedienungsanleitung Manuel d utilisation
Type 0127 Rocker valve 2/2 or 3/2-way solenoid valve 2/2 oder 3/2-Wege Magnetventil Vanne magnétique 2/2 ou 3/2 Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions...2
More informationOperating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Straight-Way Valve with Packing Gland
Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU FAS Straight-Way Valve with Packing Gland Please read these operating instructions carefully to ensure a safe operation
More informationInstructions for Safe Use
Instructions for Safe Use Certification N:o VTT 14 ATEX 041X and IECEx VTT 14.0004X Thank you for choosing SLAM Hornet portable work light with battery back up for your job site. Purpose of this manual
More informationOperating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL
Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU FAS Brass Check Valve RDL Please read these operating instructions carefully to ensure a safe operation and keep the same
More informationA17W49_MASEM_F_EN MANUAL
AW9_MASEM_F_EN MANUAL CONTENTS Identification. Manufacturer. Product name. Year of manufacture. Area of use. Declaration of conformity Technical specification. Design. Function. Technical data. Electrical
More informationTheatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)
Theatre Control Panel Instructions for Use January 2017 0197 ASF-29 (1) Contents 1. Instructions For Use 1.1. Introduction 1.2. Explanation of Symbols 1.3. General Safety Instructions Intended Use Operating
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationMounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator
Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering
More informationType 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN
Type 3709 Pneumatic Lock-up Valve Translation of original instructions Mounting and Operating Instructions EB 8391 EN Edition July 2017 Note on these mounting and operating instructions These mounting
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition
Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationVG5 Supplementary instructions
VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...
More informationPLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100
MPS-1100 User Manual Mega Pool Saver Ltd PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100 For further up to date instructions on how to install Mega Pool Saver MPS 1100, please
More informationConductor Bushings Series 8174
> Current lead-in for Ex d enclosures > 1 to 72 conductors combined in one current lead-in > Series screw-in plug-in > For voltages up to max. 1 V > For size conductor up to 7 mm 2 www.stahl.de 3163E The
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI
Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationATEX heated hoses of series WEX7
Instruction for Installation and Operation ATEX heated hoses Series WEX7 (fixed resistance heating cable) WEX7P WEX7G WEX7W Issue 10 / 2017 1 of 12 Important safety information for the use of ATEX heated
More informationDeclaration of Conformity as per Directive 97/23/EC
Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany Continuous, inline sampling valves Series 27f, with packing Operate with either; Star lever, or
More informationElectro-Pneumatic Converter YT-940 SERIES
Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product
More informationFPD20 Series. Gear wheel flow sensor
. FPD20 Series Gear wheel flow sensor Series FPD20-2 - M-5455/0315 Series FPD20 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Intended use... 5 1.2 Exclusion of
More informationInstallation, Operating & Maintenance Instructions. Variable leak valve with manual actuator. Series 590 DN 16 mm (I. D. ⅝") E
Installation, Operating & Maintenance Instructions Variable leak valve with manual actuator DN 16 mm (I. D. ⅝") This manual is valid for the following product ordering numbers: 59024-. E01 -... Sample
More informationIt is essential that the maintenance staff is qualified for electrical works and follows safety procedures.
MAINTENANCE OF POWER FACTOR CORRECTION EQUIPMENTS Procedures, suggestions and traceability The purpose of this document is to propose a maintenance method that allows to identify the elements to be maintained
More informationTranslation of the original Operating Instructions for HKS rubber compensators
Because of their flexible elements and mechanisms, HKS rubber compensators are susceptible to damage of all types and adverse loads in operation. For reliable operation of a compensator and, thus, the
More informationSafety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85
XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions
More informationMonitoring device NTS 30
P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit
More informationInstructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO
Instructions for Use Plug connection for medical gas and vacuum acc. to DIN 13260-2 / 2004 DIN EN ISO 9170-1 Table of Contents Page 1. MANUFACTURER S DATA... 3 2. INTRODUCTION... 4 3. APPLICATION... 5
More informationM-5071/1111. Electronic Pressure Switch PSW14 series
M-507/ Electronic Pressure Switch PSW4 series S TABLE OF CONTENTS Electronic Pressure Switch PSW4 Series Intended Applications... Safety Instructions... 3 Standards... 4 Warranty/Guaranty... 5 Installation/Commissioning...
More informationSiphon vessel / Priming aid
Manufacturer: sera GmbH sera-straße 1 34376 Immenhausen Germany Tel.: +49 5673 999-00 Fax: +49 5673 999-01 info@sera-web.com Keep the operating manual for future use! Record the exact type and serial number
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationPosition switches FP series
A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever
More informationPre-filter for Brushless Blower Instruction Manual
Pre-filter for Brushless Blower 781-70-702 Instruction Manual Minebea Co., Ltd. Industrial Machinery Business Unit 251-8531 1-1-1 Katase,Fujisawa,kanagawa Contact Us Industrial Machinery Product Sales
More informationSample Concentrator SBH CONC/1 Instructions for use
Sample Concentrator SBH CONC/1 Instructions for use Thank you for purchasing this piece of Barloworld Scientific equipment. To get the best performance from the equipment, and for your own safety, please
More informationOPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP
This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!
More informationMODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS
MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS 2561762B REV. B 210 Printed in U.S.A. INSTALLATION AND SERVICE INSTRUCTIONS
More informationPressure controls for hydro carbons, zone II applications, Type KPE
MAKING MODERN LIVING POSSIBLE Technical brochure Pressure controls for hydro carbons, zone II applications, Type KPE KPE pressure controls for use in refrigeration and air conditioning systems with hydrocarbons
More informationERS200. Safety Command Devices. Original Phone: operating instructions - Fax: Web:
ERS200 Safety Command Devices EN 2011/07-607330 We reserve the right to make technical changes Original Phone: operating 800.894.0412 instructions - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
More informationDWR6-205, DWR16-205, DWR6-206 Safety Pressure Limiters
Issue 2017-09-18 Datasheet 1.50-61.710-01-EN Safety Pressure Limiters pplication Safety pressure limiters with mechanical locking (switch lock) are used in steam and hot water plants in accordance with
More informationRTD temperature probes
RTD temperature probes Ex i for use in areas with an explosion hazard (Ex areas) Persons concerned: Experienced professional electricians as per EU Directive 1999/92/EC and trained personnel Operating
More informationOPERATION MANUAL PNEUMATIC VALVES
OPERATION MANUAL PNEUMATIC VALVES DIRECTIVE 2014/34/EU ATEX ENGLISH Index 1 Product identification 2 Security 3 Guarantee 4 Transportation 5 Assemblage 6 Setting up 7 Adjustments 8 Technical information
More informationE8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)
Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless
More informationOperating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22
Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU FAS Manual Brass Shut-Off Valve DN10 through DN22 Please read these operating instructions carefully to ensure a safe operation
More informationTECHNICAL MANUAL DHR60 LED. Den Haan Rotterdam MED96/98/EC
TECHNICAL MANUAL DHR60 LED MED96/98/EC SINCE 1922 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete
More informationDiaphragm Pressure Keeping Valve
Product: Diaphragm pressure keeping valve Type: 620.D 622.D 623.D 624.D 625.D 626.D 627.D Please state here the exact type and serial number of your diaphragm pressure keeping valve. (can be read off the
More informationSafety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 03.
08 Elster GmbH Edition 09.8 Translation from the German 33000 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Manual valves, flow adjusting cocks GEHV, GEH, LEH Contents Manual
More informationPressure Relief Valve DHV 718
Advantages frictionless components low maintenance low pressure increase up to fully opened valve constant low vibration controlling hermetically sealed by diaphragm for oscillating pumps for viscous media
More information3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289
3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for
More informationUSER MANUAL. JET TST and JET TST S.
USER MANUAL JET TST and JET TST S www.sisteven.com Types of Jet fans: JET TST UNI: Impulse axial fan single direction JET TST S UNI: Impulse axial fan single direction (short case) JET TST REV: Impulse
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20
More informationSafety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC
05 Elster GmbH Edition 0.5 Translation from the German 058 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Linear flow control VFC Linear flow control with actuator IFC Contents
More information