Mark 608. Gas Pressure Regulators. Pressure Regulators Mark 608 Gas Pressure Regulators SPECIFICATIONS (3/4-1-1/4 ) FEATURES 3/4-1-1/4
|
|
- Dwayne Higgins
- 5 years ago
- Views:
Transcription
1 Mark Gas Pressure Regulators 3/4-1-1/4 The MK Gas Pressure Regulator is the ideal valve for low pressure gas regulation. The self-contained low pressure gas regulator is for use on tank blanketing, gas meter inlet pressure regulating, gas burners and other low pressure air and gas applications. The MK is normally open. Increases in the outlet pressure are sensed through the aspirator causing the large elastomer diaphragm to rise, which moves the plug toward the seat. s outlet pressure decreases, the diaphragm moves down and moves the plug away from the seat to increase flow. The lever, which connects the stem to the diaphragm, amplifies diaphragm forces for tighter shutoff (only available on sizes 3/4 through 1-1/4 ). The large diaphragm and lever actuation allows the MK to act with higher sensitivity and more amplified forces over that of the typical diaphragm/stem connection. High sensitivity is important, as the MK often works with very low pressure (down to 1 or,5 ). This special actuation improves the accuracy and shutoff of the valve - two important benefits in this style of regulator. FETURES Inlet pressures up to 150 (10 ) Rugged, heavy-duty design emergency outlet pressure may reach 100% of inlet pressure without damaging valve 360 body orientation valve can be installed in any position, and can be easily repositioned while in-line Easy maintenance seat and plug can be inspected without removing body from the line ompletely self-operated no external power source required Tight shutoff soft elastomer plug provides NSI lass VI shutoff SPEIFITIONS (3/4-1-1/4 ) Line Sizes: 3/4 (N0), 1 (N5), 1-1/4 (N3) End onnections Threaded N, S, SPP Flanged 150#, 300#, PN16, PN40 Materials ody & Housing: uctile Iron, arbon Steel (16, ), Stainless Steel (35/F8M) Seat: rass (I body); Stainless Steel (S/SS body) Plug: rass and una-n (I body); Stainless Steel and Viton (S & SS body) iaphragm: una-n/nylon (I body); Viton (S & SS body) spirator Tube: cetal Service: ir or gas Shutoff: NSI lass VI Temperature Range: -0 F (-9 ) to 00 F (93 ) Maximum Inlet Pressure: 150 (10 ) Reduced Pressure ontrol Range: 1.0 to.5 inches (,5 to 6, ).0 to 5.5 inches (5,0 to 13,7 ) 4.0 to 10.0 inches (10,0 to 4,9 ) 5.0 to 30.0 inches (1,4 to 74,7 ) 0.5 to 1.75 g (0,03 to 0,1 ) 1.0 to 3.5 g (0,07 to 0,4 ) Orifice Sizes (Interchangeable) 1/8 (3mm), 3/16 (5mm), 1/4 (6mm), 5/16 (8mm), 3/8 (10mm), 7/16 (11mm), 1/ (13mm), 9/16 (14mm) Jordan Valve, a ivision of Richards Industries 3170 Wasson Road incinnati, Ohio 4509 Telephone Fax Toll-FreeTelphone: (U. S.. & anada) info@richardsind.com URL: Pressure Regulators Mark Gas Pressure Regulators
2 IMENSIONS (3/4-1-1/4 ) /4 N E nds 3 /4" (N0) 1 " (N5) 1-1/4" (N3) 150FE 7.5" ( 184mm) 7.5" ( 184mm) 7.5" (184mm) 300FE 7.50" ( 191mm) 7.50" ( 191mm) 7.50" (191mm) 150FE ( 87mm) ( 87mm) (87mm) 300FE ( 87mm) ( 87mm) (87mm) LL/TE 3.88" 3.88" 3.88" (99mm) LL 5.75" ( 146mm) 5.75" ( 146mm) 5.75" (146mm) ORER SHEMTI (3/4-1-1/4 ) How to order a MK Series Gas Pressure Regulator (3/4-1-1/4 ) I / O1S 1 Model Model Size Inches N 075 3/4" N " N /4" N3 3 ody Material I uctile Iron S arbon Steel S6 Stainless Steel 4 1 & End onnections N T S P SPP SW FSW F5 150#FE F3 300# FE F6 PN16 F7 PN & 4 Orifice inches mm 01 1/8" 3mm 0 3/16" 5mm 03 1/4" 6mm 04 5/16" 8mm 05 3/8" 10mm 06 7/16" 11mm 07 1/" 13mm 9/16" 14mm 6 5 & 6 Range 01S 1-.5",5-6, 0S -5.5" 5,0-13,7 03S 4-10" 10,0-4,9 04S 5-30" 1,4-74,7 05S ,03-0,1 06S ,07-0,4
3 The 1-1/ & size MK valves are for use on large tank blanketing applications or other low pressure gas regulation. In a tank blanketing application, the Mark is used to control the flow of the blanketing gas into the tank to maintain the proper positive pressure. Once the blanket has been established, a small flow of nitrogen is continually admitted to the tank to keep the blanket fresh. These valves are often used in conjunction with Jordan s MK 5 ack Pressure Gas Regulator, used to vent gas from the tank to prevent blanketing pressure from rising to a level that could damage the tank. The MK comes standard with an extra large diaphragm to give set point control as low as.0 (4,98 ). In addition, the S pattern body design allows for high flow capacity and also gives the option of having bubble tight shutoff. SPEIFITIONS (1-1/ - ) Line Sizes: 1-1/ (N40), (N50) End onnections Threaded N, S, SPP Flanged 150#, 300# Others upon request Materials ody: ronze (61), arbon (), Stainless Steel (F8M) Trim: 316 Stainless Steel Seat: 316 Stainless Steel iaphragm: una - N, Viton, and EPM with Polyester reinforcement Shutoff: NSI lass VI Ranges: to 5 inches (4,98 to 1,5 ) 4 to 8 inches (9,96 to 19,93 ) 8 to 8 inches (19,93 to 69,75 ) 10 to 17 inches (4,91 to 4,35 ) 14 to 8 inches (34,87 to 69,75 ) 0.75 to 1 (51,71 to 68,95 ) 1 to (68,95 to,90 ) 1.5 to 3 (0,10 to 0,1 ) 3 to 5 (0,1 to 0,34 ) v Rating: 3 (0 Kv) Pressure Temperature Rating: 100 F 7,8 ), 75 F 135 ) Maximum Pressure rop: 5 g (1,7 ) 3/4 FN Sensing Port IMENSIONS (1-1/ - 150# IFE) IMENSIONS (1-1/ - N) Flow Flow 1-1/" (N40) " (N50) 8.75" ( mm) (54mm) 4.93" ( 15mm) 4.93" (15mm) 1.3" 1.3" (99mm) ( 381mm) (381mm) 1-1/" (N40) " (N50) 6.75" ( 171mm) 6.75" (171mm) 4.93" ( 15mm) 4.93" (15mm) 1.3" 1.3" (99mm) ( 381mm) (381mm)
4 1-1/ MK FLOW PITIES Inlet Pressure Range Set Point ccuracy (0,14 ) (0,1 ) (0,34 ) (0,69 ) (1,03 ).0-5.0" 3.0" 0.75" ,98-1,5 7,47 1, (1,38 ) (1,7 ) " 9,96-19, " 19,93-69, " 4,91-4, " 34,87-69, ,71-68, ,95 -, ,10-0,1 5.0" " 7.0" , ,49 17, " " 5.0" , ,74 6, " " , ,98 37, " 5.0" , ,3 6, , ,93 68, , ,69 0, , ,50 0, ,1-0, , ,38 0, Nitrogen at 0.97 s.g. in scfh and Nm 3 /hr Operation in shaded areas not recommended
5 MK FLOW PITIES Inlet Pressure Range Set Point ccuracy (0,14 ) (0,1 ) (0,34 ) (0,69 ) (1,03 ).0-5.0" 3.0" 0.75" ,98-1,5 7,47 1, (1,38 ) (1,7 ) " 9,96-19, " 19,93-69, " 4,91-4, " 34,87-69, ,71-68, ,95 -, ,10-0,1 5.0" " 7.0" , ,49 17, " " 5.0" , ,74 6, " " , ,98 37, " 5.0" , ,3 6, , ,93 68, , ,69 0, , ,69 0, ,1-0, , ,38 0, Nitrogen at 0.97 s.g. in scfh and Nm 3 /hr Operation in shaded areas not recommended
6 MK/110/3K/ ORER SHEMTI How to order a MK Series Gas Pressure Regulator (1-1/ - ) S / VN S TF 1 Model Model Size Inches N /" N40 00 " N50 3 ody Material R ronze S arbon Steel () S 6 Stainless Steel (F8M) 4 1 & End onnections N T S P SPP SW FSW F5 150#FE F3 300# FE I 5 IFE 150# 6 5 & 6 Range 07-5" 4,98-1,5 4-8" 9,96-19, " 19,93-69, " 4,91-4, " 34,87-69, ,71-68, ,95-, ,10-0, ,1-0, & 8 ctuator S Standard 8 9 & 10 ushing TF Teflon G arbon Graphite 5 3 & 4 Seat & iaphragm N una-n VN Viton EN EPM
Mark 958 Series Sanitary Gas Back Pressure Regulators
Mark 958 Series Sanitary Gas Back Pressure Regulators (3/4" - 1") The Mark 958 Sanitary Gas Back Pressure Regulator is the ideal valve for low back pressure gas regulation for blanketing, motive force,
More informationMark 958 Series (3/4" - 1") Sanitary Gas Back Pressure Regulators
Mark 958 Series Sanitary Gas Back Pressure Regulators (3/4" - 1") The Mark 958 Sanitary Gas Back Pressure Regulator is the ideal valve for low back pressure gas regulation for blanketing, motive force,
More informationMark 630 Series. High Pressure Regulators Mark 630 High Pressure Regulators. High Pressure Regulators. Features
Mark 630 Series High Pressure Regulators The Jordan Mark 630 self-operated pressure reducing regulator is designed to provide tight shutoff and accurate regulation on high pressure gas systems. It can
More informationMark 695 Series . JORDANVALVE. Piloted Tank Blanketing Regulator 3/4"- 1"
Mark 695 Series Piloted Tank Blanketing Regulator 3/4"- 1" The Mark 695 Series piloted soft seat regulator was designed specifically to provide accurate pressure control on very low pressure tank blanketing
More informationBERMAD Waterworks. Level Control Valve with Bi-Level Vertical Float. 700 Series Model B. Features and Benefits. Major Additional Features
Level ontrol Valve with i-level Vertical Float Reservoir filling Very low supply-pressure Low noise generation Energy cost-critical systems Systems with poor water quality Reservoir outlet Distribution
More informationCOMMERCIAL. MK Series High Performance Butterfly Valve Specifications. Hot Water, Chilled Water, Condenser Water, Steam
OMMRIL MK Series igh Performance utterfly Submittal/Technical ata ray MK Series igh Performance utterfly Valves NSI lass 150 and 300 ray ontrols ommercial ivision 13788 West Road, Suite 200 ouston, Texas
More informationRB 4000 Commercial & Industrial Regulator
R 4000 ommercial & Industrial Regulator The R 4000 pressure regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants and all installations where accurate
More informationTank Blanketing. Application Jordan Valve Product Offering Competition
Tank Blanketing Application Jordan Valve Product Offering Competition What is Tank Blanketing? Padding the process of filling the empty space of a liquid storage tank with an inert gas, most likely Nitrogen
More informationVAREC 180 SERIES PRESSURE REGULATORS
Double port regulators with a variety of model options for upstream and downstream pressure control FETURES Large diaphragm and a unique double port design achieve a sensitivity of less than 5%. Set pressure
More informationMark 60 Series. Pressure Regulators Mark 60 Pressure Regulators. Self Operated Pressure Regulators. CRN Registration Number Available
Mark 60 Series Self Operated Pressure Regulators The Mark 60 Sliding Gate Pressure Regulator is used to regulate the downstream pressure to a predetermined setpoint. The spring in the Mark 60 holds the
More informationBERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features
Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level
More informationIndustrial Regulator Series 1800/2000
E S 85. Industrial Regulator Series / M Quality System QMI is ccredited by: R E I T ISO 9 ertified R E NSI R G I S T R R utch ouncil for ccreditation Measurement Engineers Since 86 merican Meter Series
More informationTank Blanketing Pressure Regulators RHPS Series
www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22
More information627 Series Pressure Reducing Regulators
627 Series Pressure Reducing Regulators Introduction The 627 Series direct-operated pressure reducing regulators (Figure 1) are for low and high-pressure systems. These regulators can be used with natural
More informationDescription Pressure range Connection thread Device Page
Pressure Regulator Pressure range onnection thread Device Page max. 22 l/min miniature -850 0 mbar 1 8 NPT V800.02 max. 22 l/min miniature -850 0 mbar 10-32 and flange V900.02 max. 0 l/min precise -1 +0,.4
More informationSafety Shut-off Valve SSV
Safety Shut-off Valve SSV 8200-8300 < Accurate operation < Compact design < Easy maintenance Applications The safety shut-off valve is designed for use in gas distribution, and pressure regulation systems.
More informationCA14 SG Iron Air and Gas Trap ½" and ¾" (Screwed)
ert. No. LRQ 9638 ISO 91 14 SG Iron ir and Gas Trap ½" and ¾" (Screwed) TI-P148-1 ST Issue 6 escription The 14 is a range of float type automatic liquid drainers for air and gas systems. The body and cover
More informationPRESSURE REDUCING VALVE RP45 (EN)
PRESSURE REDUCING VALVE RP45 (EN) DESCRIPTION The ADCA RP45 series pressure reducing valves are single seat bellows sealed controllers, operating without auxiliary energy, designed for use on steam, compressed
More informationBERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features
Pressure Reducing Valve Flow and leakage reduction Cavitation damage protection Throttling noise reduction Burst protection System maintenance savings The Pressure Reducing Valve is a hydraulically operated,
More informationRR 16 Commercial & Industrial Regulator
Gas RR 16 Commercial & Industrial Regulator Applications The RR 16 regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants, as well as for all installations
More informationTypes ACE95 and ACE95Sr Tank Blanketing Valves
Types ACE95 and ACE95Sr Tank Blanketing Valves Bulletin 74.1:ACE95 May 2010 W9133 W8155 Figure 1. Type ACE95 Tank Blanketing Valve Figure 2. Type ACE95Sr Tank Blanketing Valve Features Fully Balanced Pilot
More informationType EZH Relief or Backpressure Regulator
Bulletin 71.4 D103574X012 Type EZH December 2017 Type EZH Relief or Backpressure Regulator P1668 Figure 1. Type EZH Relief Valve or Backpressure Regulator Features Bubble Tight Shutoff A knife-edged metal
More informationCOMMERCIAL. Resilent Seated Butterfly Submittal/Technical. Technical Specifications. Application COMMERCIAL. Service
OMMRIL Resilent Seated utterfly Submittal/Technical pplication ray s NY and series resilient seated butterfly valves set the design standard for quality, reliability and long life in a wide variety of
More information299H Series Pressure Reducing Regulators
September 12 299H Series Pressure Reducing Regulators Inlet Pressure up to psig / 1 bar Compact ±1% Accuracy for Fixed Factor Billing (PFM) Rugged Construction Integral Pilot Easy to Maintain W713 Figure
More informationThe Shand & Jurs Model Vapor Guard Tank Blanketing Valve
Lower maintenance due to fewer parts Occupies less space, less stress to tank Teflon is inert to most chemicals; extends service life Simplifies and lowers maintenance cost Optimizes flow of blanketing
More informationVBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)
VGx-xx-xx Externally Threaded Control all Valves PN25 (DN15 TO DN32) PPLICTION The VG2 2-Way and VG3 3-Way Control all Valves control hot and chilled water with glycol solutions up to 50% according to
More informationVBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)
VGx-xx-xx Externally Threaded Control all Valves PN25 (DN15 TO DN32) PPLICTION The VG2 2-Way and VG3 3-Way Control all Valves control hot and chilled water with glycol solutions up to 50% according to
More informationType Cronos Pressure Reducing Regulator
Type Cronos Pressure Reducing Regulator March 2002 E0838 Figure 1. Type Cronos Regulator Features! Control ccuracy Keeps constant inlet pressures to downstream equipment by accurately controlling system
More informationModel 1800 PFM Series Regulator. Technical Bulletin
Model 0 PFM Series Regulator Technical Bulletin Model 0 PFM Series Regulator 0 Elster American Meter The 0 PFM Series regulators are designed to control natural gas, air, nitrogen, carbon dioxide, propane
More informationT208VR Series Tank Blanketing Vacuum Regulator
February 2014 T208VR Series Tank Blanketing Vacuum Regulator Figure 1. Typical T208VR Series Vacuum Regulator Introduction The T208VR Series direct-operated vacuum regulators are used where a decrease
More informationR10 / R11 General Purpose Regulators
N T 4 7 9 atalog -2 R / R Series (Revised -7-8) General Purpose Regulators /4, /8 & /2 Inch Ports R / R General Purpose Regulators Features High Flow Performance Featuring Rugged esign for the Most emanding
More informationW68 Series Control Valves
Indianapolis hicago San Juan www.hollandapt.com 800-800-8464 W Series ontrol Valves W68 Series ontrol Valves pplication W68 valves are used in flow and pressure control applications. These valves are pneumatically
More informationANDERSON GREENWOOD TANK BLANKETING REGULATORS
Part of a complete system that incorporates a pilot operated, dome-loaded diaphragm type regulator capable of reducing blanketing gas in a single step, providing bubble-tight shut-off and low maintenance.
More informationACCREDITED. Technical specifications series
nti-pollution check valves 0-0-0-0-0 series REITE ISO 0 FM LEFFI 000/ G replaces dp 000/0G Function The anti-pollution check valve is a protective plumbing device capable of preventing the backflow of
More informationSABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company
CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN
More informationType 99 Pressure Reducing Regulators
Type 99 Pressure Reducing Regulators Bulletin 71.2:99 July 2008 W6527 W2676 D100138X012 www.emersonprocess.com/regulators Features Wide Variety of Applications Natural gas distribution systems, gas supply
More informationModel TB 3-16 TECHNICAL BULLETIN. Secure-Gard Pilot Operated Vent Valve (POVV) BENEFITS TYPICAL APPLICATIONS FEATURES
TECHNICAL BULLETIN 1049 - TB 3-16 Model 1049 Secure-Gard Pilot Operated Vent Valve (POVV) ISO Registered Company The Model 1049 is a pilot operated vent valve specifically designed for low-pressure storage
More informationCAST IRON VALVES FLOAT VALVE
CAST IRON VALVES FLOAT VALVE NETAFIM CAST IRON VALVES FLOAT VALVE INLINE 25-400MM ANGLE 50-100MM SPECIFICATIONS Manufactured to ISO 9001 Available Valve sizes INLINE Flanged 50mm to 600mm & Threaded 19mm
More informationCash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified
Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified TYPE G-4 DESCRIPTION FIG 2042 - Bronze FIG 2043 - Bronze
More informationRR 16 Commercial & Industrial Regulator
RR 16 Commercial & Industrial Regulator The RR 16 regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants, as well as for all installations where accurate
More informationRobolux Multiway Multiport Diaphragm Valve, standard product range
Robolux Multiway Multiport iaphragm Valve, standard product range Increased process efficiency Reduced installation costs Reduced number of valves and welds Zero dead volume and no contamination Type 2035
More informationCASH VALVE TYPE KP BACK PRESSURE VALVES
A high capacity pilot operated back pressure valve that offers accurate control and dependable protection against overpressure conditions FEATURES Automatically maintains maximum pressure in a vessel or
More informationVolume Booster. Volume Booster Description Supply pressure Pressure range Connection Device Page max. bar bar thread
Volume ooster Supply pressure Pressure range onnection Device Page max. bar bar thread precise differential pressure also 17 0 1 / 10 and G 3 8 R50.02 differential pressure also 10 0.2 1 / 8 ¼ NPT 53.19
More informationCSB400 Series Commercial / Industrial Pressure Reducing Regulators
CSB400 Series Commercial / Industrial Pressure Reducing Regulators Bulletin 71.1:CSB400 April 2011 CSB400 SERIES PRESSURE REDUCING TYPICAL CSB403 WITH INTEGRAL TRUE-MONITOR TYPICAL CSB404 WITH INTEGRAL
More informationJSHM Series Hand Metering Valves
Hand metering valve for precise manual control of iopharm and Pharmaceutical gas or liquids The JSHM Series allows precision manual adjustment of pharmaceutical liquid and gas flows. These valves are most
More informationPilot Operated Safety Relief Valves For Liquified Gas Carriers
Pilot Operated Safety Relief Valves For Liquified Gas Carriers LUCET Features and dvantages High seat tightness - s the force that holds the disc on the nozzle increases with the pressure, the valve remains
More informationPRO-50 Instrument Supply Regulator
Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits
More informationBERMAD Waterworks. Pressure-Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features
Pressure-Reducing Valve Flow and leakage reduction Cavitation damage protection Throttling noise reduction Burst protection System maintenance savings The Pressure-Reducing Valve is a hydraulically-operated,
More informationTypes ACE95 and ACE95Sr Tank Blanketing Valves
August 2013 Types ACE95 and ACE95Sr Tank Blanketing Valves W9133 W8155 Figure 1. Type ACE95 Tank Blanketing Valve Figure 2. Type ACE95Sr Tank Blanketing Valve Features Fully Balanced Pilot Design Reduces
More information1800CPB2 Pilot-Loaded Service Regulators
1800CPB2 Pilot-Loaded Service Regulators Technical Bulletin www.elster-americanmeter.com Table of Contents 1800CPB2 Regulator Information................ 2-3 1800CPB2 Capacity Performance................
More informationSERIES 3000 BLANKET GAS REGULATORS
SERIES 000 BLANKET GAS REGULATORS Numbers:,, P, 00A, 00, 01L, 01H, 01HP WHAT IS A BLANKET GAS REGULATOR? A blanket gas regular supplies an inert gas prevent a vacuum from developing when liquid is removed
More informationCash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified
Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot
More information66 Series Direct-Operated Regulators and Vacuum Service Equipment
66 Series Direct-Operated Regulators and Vacuum Service Equipment November W193/IL Figure 1. Exterior of Type 66 or 66Z Regulator Introduction Fisher 66 Series direct-operated pressure-reducing regulators
More informationType 1190 Low-Pressure Gas Blanketing Regulator
April 202 Type 90 Low-Pressure Gas Blanketing Regulator W7428 Figure. Type 90 Low-Pressure Gas Blanketing Regulator Introduction The Type 90 low-pressure gas blanketing regulator is used for extremely
More informationJSRH Series. Sanitary Valves JSRH Series High Flow Pressure Reducing Valves. High Flow Bio-Pharma Clean Gas Pressure Reducing Valves
JSRH Series High Flow Bio-Pharma Clean Gas Pressure Reducing Valves The JSRH Series high purity gas pressure regulator was designed and built specifically for Bio-Pharma gas applications. It may also be
More informationDescription Supply pressure Pressure range Connection Device Page max. bar bar thread
Pressure Regulators Supply pressure Pressure range onnection Device Page max. bar bar thread Maxi -Series, robust, interlockable 1 0. 1.8 / 17 G¼ - G1 R0, R1.0 made of plastic, also for liquids 1,5 0 4
More informationSpring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators
Product Line Brochure J0B Effective Date 2/01 Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators P R O D U C T L I N E O V E R V I E W Regulator
More informationRB 4700 Commercial & Industrial Regulator
RB 4700 Commercial & Industrial Regulator The RB 4700 regulator is designed for use in industrial and distribution applications such as district station and heating plants, and for industrial customers.
More informationV DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012
V2015.2 DFX Series Direct-Operated Tank Blanketing Regulator Manual D103808X012 Contents 1. Introduction... 3 2. Specifications... 3 3. Features... 3 4. Dimensions... 4 5. Principle of Operation... 4 6.
More informationGas Pressure Regulator HON 270 MK2
Gas Pressure Regulator HON 270 MK2 PRODUCT INFORMATION Serving the Gas Industry Worldwide Introduction, Application, Features & Technical Data Introduction The HON 270 MK2 regulator is a direct acting,
More informationi n f b e r m a d. c o m w w w. b e r m a d. c o m
asic Valve IR-900-M ydrometer with Magnetic Drive The ERMAD Model IR-900-M is a unique product integrating both a vertical turbine oltman-type water meter and a diaphragm actuated hydraulic control valve.
More information1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG
A C E D SB-8520.2 1800CPB2 Service Regulators Maximum Inlet 125 PSIG AMC Quality System QMI is Accredited by: C R E D I T ISO 9001 Certified Certificate #006697 R E ANSI RAB G I S T R A R Dutch Council
More information1800C and 1800C-HC Series Service Regulators
1800C and 1800C-HC Series Service Regulators Installation Instructions www.elster-americanmeter.com General Information: The 1800C and 1800C-HC Regulators are available as Full Capacity Internal Relief
More informationJSRH Series. Sanitary Valves JSRH Series High Flow Pressure Reducing Valves. High Flow Bio-Pharma Clean Gas Pressure Reducing Valves
JSRH Series High Flow Bio-Pharma Clean Gas Pressure Reducing Valves The JSRH Series high purity gas pressure regulator was designed and built specifically for Bio-Pharma gas applications. It may also be
More informationCash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control
Cash Valve Type G-4 Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases Issued - March 2001 CAVMC-0512-US-0609 ISO 9001 Certified Flow Control Description FIG 2042 - Bronze FIG 2043 - Bronze
More informationADCATROL PNEUMATIC CONTROL VALVES V403 (V403 globe valves series with linear actuators PA or EL series)
TROL PNEUMTIC CONTROL VLVES V40 (V40 globe valves series with linear actuators P or EL series) DESCRIPTION The PV40 control valves are three-way valve body for mixing service. The P pneumatic actuator
More informationType ACE95jr Tank Blanketing Valve
Type ACE95jr Tank Blanketing Valve Features Fully Balanced Plug Design Reduces Inlet Pressure Sensitivity Bulletin 74.1:ACE95JR May 2010 Stainless Steel Construction Available High Sensitivity Self-Contained
More information2-port and 3-port seat valves, PN16
s 4 47 VVI47 VXI47 CVTIX 2-port and 3-port seat valves, PN6 with internally threaded connections VVI47.. VXI47.. ronze valve body CC49K (Rg5) DN 5...5 k vs 2.5...4 m 3 /h Internally threaded connections
More information1805 Series Relief Valves
October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications
More informationSERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.
SERIES 30 PROTECTOSEAL 1 2" NPT inlet and outlet standard Direct acting valve mechanism Optional flanged or threaded inlet and outlet connections available Inlet gas pressures from 10 PSIG to 200 PSIG
More informationZUERCHER MRCib Series
Pressure/Vacuum Rating Max inlet pressure: 16 bar Full Vacuum Leak Tight to EN 12266-1:2003 Leakage rate A For T = -10 C to +150 C: Leakage rate A For T = -20 C to -10 C: Leakage rate C Control Spring
More information1800CPB2 Service Regulators
SB 8520.5 1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG Table of Contents 1800CPB2 Regulator Information................ 2-3 1800CPB2 Capacity Performance................ 4-6 1-1/4" Models,
More informationS300 Series. Valve Link. Features. Fisher Controls
S0 Series Self-Operated Type VL FIELDVUE Regulators Valve Link Fisher Controls May 198 Bulletin 71.1:S0 The S0 Series self-operated, spring-loaded regulators are used for pressure-reducing control in a
More informationPrinciple of Operation. Features. Applications. CL34 Operating Schematic
..GAS.REGS..GAS.REGS Principle of Operation (See Operating Schematic below) pressure connected by tubing to the pilot regulator, is utilized as supply pressure for pilot. pressure of the Regulator is applied
More informationJR Series. Gas Pressure Reducing Valves. a division of Jordan Valve GAS PRESSURE REDUCING VALVES
a division of Jordan Valve JR Series Gas Pressure Reducing Valves GAS PRESSURE REDUCING VALVES The LowFlow JR Series line of high pressure regulators have the ability to handle very high pressures and
More information94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?
94270 What is Tank Blanketing? blanketing systems are used to prevent the escape of liquid vapors into the atmosphere or to prevent moisture from entering a tank and contaminating its contents. A tank
More informationMaximum Inlet Pressure. Maximum Outlet (Casing) Pressure. Outlet Pressure Range. 2-inches w.c. to 10 psig (5 mbar to 0,69 bar) Flow Coefficients
Introduction The quickreacting S200 Series pressure reducing service regulators are typically used in industrial or commercial installations to minimize the shock effect of sudden downstream load changes
More informationJSR Series. Sanitary Valves JSR Series Ultra-High Pressure Reducing Valves. High Purity Bio-Pharma Gas Pressure Reducing Valves.
JSR Series High Purity Bio-Pharma Gas Pressure Reducing Valves JSR is the first high purity gas pressure regulator designed and built specifically for hygienic, ASME BPE gas applications. Traditionally,
More informationN2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance
DST100 / DST200 TYPE N2 Blanketing Valve INSTRUCTION MANUAL CONTENTS General Description Operation Installation Maintenance K.S.P.C 488-1 Wolha-ro, Tongjin-eup, Gimpo-si, Gyeonggi-Do, Korea Tel : +82-31-998-3825~7
More informationTECHNICAL DATA. than the water inlet pressure to the concentrate
Foam102a 1. DESCRIPTION The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with 3M foam concentrates. This system consists of a standard wet pipe sprinkler
More informationType 299 Pressure Reducing Regulators
Type 299 Pressure Reducing Regulators Fisher, Fisher-Rosemount, and Managing The Process Better are marks owned by Fisher Controls International, Inc. or Fisher-Rosemount Systems, Inc. All other marks
More information1200B2 Series Service Regulators. Instruction Manual
00B Series Service Regulators Instruction Manual 00B Series Service Regulators 0 Elster American Meter 00B Series Service Regulators General Information The 00B Series Service Regulators are available
More informationBERMAD Irrigation. Automatic Metering Valve (AMV) 900-D Series. Basic Valve ??????? IR-900-D.
asic Valve??????? I-9-D Automatic Metering Valve (AMV) The EMAD Model I-9-D is a unique product integrating both a vertical turbine oltman-type water meter and a pilot operated, diaphragm actuated control
More informationCSB400 Series Commercial / Industrial Pressure Reducing Regulators
October 2015 CSB400 Series Commercial / Industrial Pressure Reducing Regulators P1424 TYPE CSB400 PRESSURE REDUCING P1426 TYPICAL TYPE CSB403 WITH INTEGRAL TRUE-MONITOR P1425 TYPICAL TYPE CSB404 WITH INTEGRAL
More informationBall Valves. Stainless Steel Ball Valves Pag Pag Pag Pag Pag Pag. 9.
86300 Pag. 9.6 86310 Pag. 9.6 86320 Pag. 9.6 86330 Pag. 9.6 86700 Pag. 9.6 86710 Pag. 9.7 86720 Pag. 9.7 6300 Pag. 9.7 6310 Pag. 9.7 6400 Pag. 9.8 6410 Pag. 9.8 6560 Pag. 9.8 6570 Pag. 9.8 86900 Pag. 9.9
More informationCALEFFI. Reduced pressure zone backflow preventer. 574 series 01022/18 NA D E C F B D E. Function
Reduced pressure zone backflow preventer series LEFFI 01022/18 N REITE ISO 9001 FM 216 ISO 9001 No. 000 Function The backflow preventer can be used in all plumbing systems where there is danger of the
More information299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012
Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of
More informationSPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION
DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds
More informationVolume Booster. Description Supply pressure Pressure range Connection Device Page max. bar bar thread
Volume ooster Supply pressure Pressure range onnection Device Page max. bar bar thread precise differential pressure also 17 0 1 / 10 and G 3 8 R50.02 ratio 1:1 up to 1: 17 0 10 and G 3 8 R750.03 different
More informationGas Pressure Regulator HON 280H - 309
Gas Pressure Regulator HON 280H - 309 PRODUCT INFORMATION Serving the Gas Industry Worldwide 2 GAS PRESSURE REGULATOR HON 280H - 309 Technical Data Introduction The HON 280H-309 are spring loaded, externally
More information299H Series. 1% Accuracy for Fixed Factor Billing (PFM) I nlet Pressure up to 175 psig / 12.1 bar. Rugged Construction. Compact.
Bulletin 71. D3X01 99H Series May 18 99H Series Pressure ucing Regulators I nlet Pressure up to psig / bar Compact Integral Pilot Figure 1. 99H Series Pressure ucing Regulators High Capacity Robust O utlet
More informationJR Series. Gas Pressure Reducing Valve GAS PRESSURE REDUCING VALVE
JR Series Gas Pressure Reducing Valve GAS PRESSURE REDUCING VALVE The LowFlow JR Series line of high pressure regulators have the ability to handle very high pressures and very low flows. These valves
More information1800B2 and 1800B2-HC Series Service Regulators. Technical Bulletin
800 and 800-H Series Service Regulators Technical ulletin 800 and 800-H Series Service Regulators 0 lster merican Meter The 800 Series pressure regulators are designed to control natural gas, air, nitrogen,
More informationV DGX Series. Direct-Operated Regulators Manual D103834X012
V2015.3 DGX Series Direct-Operated Regulators Manual D103834X012 Contents 1. Introduction... 3 2. Specifications... 3 3. Features... 3 4. Dimensions... 4 5. Principle of Operation... 5 6. Performance Curves...
More informationBACK PRESSURE / SUSTAINING
In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series of the OCV control valves.
More informationNoth American 7347 High Pressure Gas Regulators
Combustion Noth American 7347 High Pressure Gas s Bulletin 7347 7347 s reduce high gas supply pressures to practical use levels. Since capacities will vary with the pressure drop across the regulator (see
More informationType 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator
January 2009 Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator Introduction The Type 310A pilot-operated high-pressure regulator (Figure 1) is used where high capacity
More informationCentury Valve. Flow Control. Century Valve Hand Valves, Large Bore, Severe Service, and Isolation Valves. Total Flow Control Solutions.
Century Valve Bore Sizes: 1/8 [3.2 mm] 3/16 [4.8 mm] 5/16 [8 mm] 3/8 [9.5 mm ] 7/16 [11 mm] 5/8 [16 mm] Straight through (roddable) and globe-pattern models. Needle (rising plug) and ball stem end models.
More informationTypes ACE95 and ACE95Sr Tank Blanketing Valves
October 2014 Types ACE95 and ACE95Sr Tank Blanketing Valves W9133 W8155 Figure 1. Type ACE95 Tank Blanketing Valve Figure 2. Type ACE95Sr Tank Blanketing Valve Features Fully Balanced Pilot Design Reduces
More information829S1 Series Flexflo Pilot
REDQ Regulators The Model 829S1 Provides Versatile Pressure Regulation At An Economical Price. The Model 829S1 Flexflo Pilot is a reversible pressure control regulator (seat & nozzle) that is used in conjunction