Product Data. CK5A, CK5B, CK5P Furnace N-Coils. Sizes A018 thru A060
|
|
- August Dennis
- 5 years ago
- Views:
Transcription
1 Product Data CK5A, CK5B, CK5P Furnace N-Coils Sizes A018 thru A060 This vertical design N-coil is a furnace coil designed to provide the highest standards of reliability and durability. The coils are offered in 3 configurations. The CK5A has a painted case and comes with a piston. The CK5B has an embossed case and comes with a piston. Both the CK5A and CK5B can be used with R-22 or Puron systems. The third coil, the CK5P, is in a painted case and comes with a Puron TXV and is specific to Puron systems. The coils are offered in standard, overhang, and wide configurations for use in multiple installation applications. Additionally, the cased coils are offered in a Transition configuration, which is designed to fit two different furnace widths without field modification. Easy maintenance is provided as the coil slides out of the cabinet after removing the access door and service panel. The coils are available in sizes 018 through 060 (1-1/2 to 5 tons). Two full lines of Tin-Plated copper coil models are available (CK5A and CK5P). T models are built with special hairpins Tin- Plated to resist both general pitting corrosion and excessive indoor corrosion Formicary Corrosion. (Formicary Corrosion is an industry phenomenon). COMMON FEATURES Water Management The CK coil design does an excellent job of water management. The coils are designed to avoid water blow-off Copyright 2003 Carrier Corporation Form No. CK5A-5PD
2 into the ducts by directing condensate away from the fins and into the drain pan. The coil s drain pan design provides improved condensate removal into the drain. This improves indoor air quality. Durable Condensate Pan Each coil is equipped with a corrosion resistant condensate drain pan. The condensate drain pan is designed with a slope to help ensure proper drainage, improved moisture removal, and home comfort. Compact Design Unique design offers as much as 2 in. less in height to aid in tight installations. Brass Inserts Every condensate pan features two 3/4 in. female threaded brass insert connections. The unique brass inserts provide for a leak-free condensate line connection to prevent water damage. Refrigerant Connections The coils are provided with proven sweatconnections for leak-free operation maintaining system reliability. Burst Pressures These coils meet or exceed burst pressure of 2100 psi which is at least three to five times the pressure they will see in actual application. External Piston Location Provides easy access to the piston metering device, for quick installations and standard service procedures. Liquid Line Bracket Holds the piston body in place for quick, safe piston access without needing a back-up wrench. Teflon Ring The ring, installed inside the liquid line connection, is the best option for preventing refrigerant leaks and future service calls. Teflon works with both Puron and R-22 Refrigerant. Protective Tube Sheets Protect the durable copper tubing from being damaged during the manufacturing and installation process. Warranty All CK5A/CK5B/CK5P coils feature a 5-year limited warranty on parts, with additional extended warranties available for the system. 2
3 Model number nomenclature C K 5 A X A 018 (0,T)14 C Coil /2 Ton Ton /2 Ton Etc. (0,T) /16 in. (0,T) /2 in. (0,T)21 21 in. (0,T) /2 in. K Cased, N-Coil 5 Upflow/Downflow A Standard E High Efficiency T Transition W Wide X Max Cap Position A Painted B Embossed P Puron, TXV Painted 0 Standard Copper Coil T Tin-Plated Copper Coil UNITARY AIR CONDITIONING UNITARY HEAT PUMP REGISTERED QUALITY SYSTEM MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH CERTIFICATION APPLIES ONLY WHEN USED WITH PROPER COMPONENTS AS LISTED WITH ARI ARI EQUIPMENT STANDARD 240 3
4 DIMENSIONS (In.) UNIT SERIES A B C D E F G CK5(A,P)XA018(0,T)14* CK5BXA018014* CK5(A,P)XA024(0,T)14* CK5BXA024014* CK5(A,P)XW024(0,T)17 CK5BXW CK5(A,P)XA030(0,T)14* CK5BXA030014* CK5(A,P)XW030(0,T)17 CK5BXW CK5(A,P)XA036(0,T)17* CK5BXA036017* CK5(A,P)XT036(0,T)17* CK5BXT036017* CK5(A,P)XW036(0,T)21 CK5BXW CK5(A,P)XA042(0,T)21* CK5BXA042021* CK5(A,P)XT042(0,T)21* CK5BXT042021* CK5(A,P)XA048(0,T)21* CK5BXA048021* CK5(A,P)XE042(0,T)17 CK5BXE CK5(A,P)XT048(0,T)21* CK5BXT048021* CK5(A,P)XW048(0,T)24 CK5BXW CK5(A,P)XA060(0,T)24* CK5BXA060024* CK5(A,P)XT060(0,T)24* CK5BXT060024* CK5(A,P)XX060(0,T)24 CK5BXX SHIPPING WEIGHT (LB) A 14-3/ /8 12-7/16 5 5/8 2-1/8 1-3/8 29-1/2 A 14-3/ /8 12-7/16 7-1/16 5/8 2-1/8 1-3/8 33 A 17-1/2 12-5/8 15-3/4 6-11/16 5/8 2-1/8 1-3/8 34 A 14-3/ /8 12-7/16 9-1/16 3/4 2-1/8 1-3/8 36-1/2 A 17-1/2 14-5/8 15-3/4 8-13/16 3/4 2-1/8 1-3/8 38-1/2 B 17-1/ / /16 3/4 2-1/8 1-3/8 44 A 17-1/2 19-1/4 15-3/4 13-1/16 3/4 4-3/8 3-5/8 50 B /4 10-1/2 3/4 2-1/8 1-3/8 45 B /4 10-1/2 7/8 2-1/8 1-3/8 45 A /4 19-1/4 12-3/4 7/8 4-3/8 3-5/8 53 B / /16 7/8 2-1/8 1-3/8 48-1/2 B 17-1/ / /16 7/8 2-1/8 1-3/8 46-1/2 A /4 19-1/ /16 7/8 4-3/8 3-5/8 57 B 24-1/ /4 12-3/16 7/8 2-1/8 1-3/8 50-1/2 A 24-1/2 22-1/ /4 16-1/2 7/8 2-1/8 1-3/8 63 A 24-1/2 24-5/ /4 18-3/4 7/8 4-3/8 3-5/8 70 A 24-1/2 26-5/ /4 14-1/4 7/8 2-1/8 1-3/8 72 * In these models the coil can be removed from the casing and installed as an uncased coil without needing to field fabricate the coil enclosure to prevent air bypass. NOTE: For the 10th digit position in the model number, 0 = standard copper and T = tin-plated copper. 3 8 I.D. Puron TXV Connection CK5P NOTE: 1. Series designation is the 14th position of unit model number C B E SUCTION LINE I.D. Liquid Line CK5A/B IN.PLUGGED DRAIN D F G 3 4 IN. NPT DRAIN A FRONT RIGHT SIDE A
5 Performance data GROSS COOLING CAPACITIES (MBH) UNIT SIZE A018 A024 W024 A030 W030 A036 T036 W036 A042 T042 A048 E042 T048 W048 SATURATED TEMPERATURE LEAVING EVAPORATOR ( F) INDOOR COIL AIR CFM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC SHC BF CFM Cubic Ft per Minute EWB Entering Wet Bulb ( F) TC Gross Cooling Capacity 1000 Btuh SHC Gross Sensible Capacity 1000 Btuh BF Bypass Factor MBH 1000 Btuh
6 Performance data continued UNIT SIZE A060 T060 X060 CFM Cubic Ft per Minute EWB Entering Wet Bulb ( F) LWB Leaving Wet Bulb ( F) TC Gross Cooling Capacity 1000 Btuh SHC Gross Sensible Capacity 1000 Btuh BF Bypass Factor MBH 1000 Btuh GROSS COOLING CAPACITIES (MBH) SATURATED TEMPERATURE LEAVING EVAPORATOR ( F) INDOOR COIL AIR CFM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC SHC BF Direct interpolation is permissible. Do not extrapolate. 4. SHC is based on 80 F db temperature of air entering coil. Below 80 F db, subtract (Correction Factor x CFM) from SHC. Above 80 F db, add (Correction Factor x CFM) to SHC. 5. All data points are based on 10 F superheat leaving coil. 6. Bypass Factor = 0 indicates no psychometric solution. Use bypass factor of next lower EWB for approximation. NOTES: 1. Contact manufacturer for cooling capacities at conditions other than shown in table. 2. Formulas: sensible heat cap. Leaving db = entering db 1.09 x CFM Leaving wb = wb corresponding to enthalpy of air leaving coil (h LWB ) total capacity (Btuh) h LWB = h EWB 4.5 x CFM where h EWB = enthalpy of air entering coil. ENTERING AIR DRY BULB TEMPERATURE ( F) UNDER 75 BYPASS Over 85 FACTOR Correction Factor Use formula shown below Interpolation is permissible. Correction Factor = 1.09 x (1 BF) x (db 80) UNIT CK5P-018, 024, 030 CK5P-036, 042 CK5P-048 CK5P-060 INDOOR COIL TXV FACTORY-INSTALLED INDOOR TXV SIZE EA36Y124 EA36Y134 EA36Y144 EA36Y154 6
7 COIL STATIC PRESSURE DROP (In. WC) UNIT SIZE BULB AIR QUANTITY (CFM) A018 A024 W024 A030 W030 A036 T036 W036 A042 T042 A048 T048 W048 E042 A060 T060 X WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY INDOOR COIL PISTONS UNIT FACTORY-INSTALLED INDOOR PISTON SIZE CK5A/CK5BA CK5A/CK5BA024, W CK5A/CK5BA030, W CK5A/CK5BA036, W036, T CK5A/CK5BA042, T042, E CK5A/CK5BA048, T048, W CK5A/CK5BA060, T060, X
8 Carrier Corporation Syracuse, New York Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 Page 8 Catalog No. 02CK-5A5 Printed in U.S.A. PC 101 Form CK5A-5PD Tab 3d 2d Replaces: CK5A-4PD
CASED HORIZONTAL FURNACE COIL. Model CK3B. Form No. SS-CK3B-01 FEATURES
SIZES AVAILABLE: The horizontal N-Coil is available in six coil sizes (024 through 060). It is designed to provide the highest standard of reliability and durability. CASING: The CK3B coil casing is unpainted
More informationModel 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.
EVAPORATOR COILS A COIL UNCASED R 22 or R 410A SYSTEMS 1 5 Tons WEAU Certification applies only when the complete system is listed with ARI ISO 9001:2000 REGISTERED R 410A R 22 Size Shipping Weight Size
More informationProduct Data. CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil --- Cased and Uncased Upflow, Downflow CAPVP / CARVP
CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil Cased and Uncased Upflow, Downflow Product Data CAPVP / CARVP A06001 A06002 CAPVU / CARVU The CAPVP, CARVP, CAPVU, and CARVU evaporator coils incorporate
More informationProduct Data CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW DESIGN FEATURES
CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW Product Data CAPVP / CARVP A06001 A06002 CAPVU / CARVU The CAPVP, CARVP, CAPVU, and CARVU evaporator coils incorporate
More informationProduct Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)
CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE Product Data (3619, 4823, 6025) A06009 A07904 The CAPMP and CARMP evaporator coils incorporate proven standards for reliable system operation and
More informationFMU4X, FMC4X FMU4P, FMC4P
ENVIRONMENTALLY SOUND REFRIGERANT FMU4X, FMC4X FMU4P, FMC4P Product Specifications HORIZONTAL FAN COILS FMU4P and FMC4P 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2 and 2 1/2 Tons ALL MODELS Horizontal
More informationProduct Data. FB4CS, FB4CQ (50 Hz) Direct Expansion Fan Coil R- 410A Refrigerant Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST
, Q (50 Hz) Direct Expansion Fan Coil R- 410A Refrigerant izes 018 thru 060 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The 50 Hz fan coil has the proven technology of Carrier fan coil units with Puron
More informationProduct Data. FA4B FB4B FC4C Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest
Product Data FA4B FB4B Direct Expansion Fan Coil Sizes 018 thru 070 A02305 Air Handling Technology At Its Finest Carrier s FA4B, FB4B, and direct expansion multipoise fan coils are designed to cover a
More informationFA4B FB4B FC4C DIRECT EXPANSION FAN COIL. Sizes 018 thru 070. Form No. PDS FA4B Air Handling Technology At Its Finest
DIRECT EXPANSION FAN COIL FA4B FB4B Sizes 018 thru 070 Air Handling Technology At Its Finest The FA4B, FB4B, and direct expansion fan coils are designed to cover a wide range of air handling requirements.
More informationProduct Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest
Product Data FA4A FB4A Direct Expansion Fan Coil Sizes 018 thru 070 Air Handling Technology At Its Finest Carrier s FA4A, FB4A, and direct expansion multipoise fan coils are designed to cover a wide range
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS C3, C4, C5 Uncased Indoor Coils (RepLcoil) 2 3/8" 1 3/8" 12 1/8" H 14 1/2" 19 1/2" 2 1/2" W "A" Coil Features Anteater Coil Technology: The Anteater TM coil is made with Uniguard
More informationCoils Designed to Fit Your Requirements. Temtrol Manufacturing OEM & Replacement Coils Since 1955
Temtrol Manufacturing OEM & Replacement Coils Since 1955 Coils Designed to Fit Your Requirements Chilled & Hot Water Direct Expansion Steam Distributing Condenser Standard Steam Quick Ship Program with
More informationAIR CONDITIONERS WA14**W SERIES
FORM NO. A66-225 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light
More informationEvaporator (DX) Freon Applications 1 12 Tons MHF
Evaporator (DX) Freon Applications 1 12 Tons > > Used For small to medium freon applications The Global Leader In Heat Exchange Technology With seven decades of experience and commitment to total client
More informationAIR CONDITIONERS WA14 SERIES
FORM NO. A66-220 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light
More informationD A T A S H E E T. Technical Data. Maximum Working Gauge Pressure (bar) Capillary Tube Length (m) 1.5 (5Ft) Burst Gauge Pressure (bar) 234.
TRAE Stretch series of Thermal Expansion Valves are designed predominantly for AC, heat pumps, close control, industrial process cooling applications, and transportation AC with HP demand. The new TRAE
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS 1NP0680 - PROPANE CONVERSION FOR USE WITH MODELS: PM8, PC8, PM9, PC9, FL9M, FL9C, FC9M, FC9C This conversion kit is to be installed by a qualified service agency
More informationTWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3
TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3 The following tasks parallel the Jr. Tech (JT-1, 2, 3) description and development plan and use the Refrigeration and Air conditioning
More information4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP
4HP15 PRODUCT SPECIFICATIONS 15 SPLIT SYSTEM HEAT PUMP FORM NO. 4HP15-100 (12/2017) FEATURES AND BENEFITS R410A Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for
More information2-step solenoid valve Type ICLX
Data sheet 2-step solenoid valve ICLX 32-150 ICLX 2-step solenoid valves belong to the ICV family. ICLX are used in suction lines for the opening against high differential pressure, e.g. after hot gas
More information2-step solenoid valve Type ICLX
Data sheet 2-step solenoid valve ICLX 32-150 ICLX 2-step solenoid valves belong to the ICV family. ICLX are used in suction lines to open against high differential pressure, e.g. after a hot gas defrost
More informationFSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities
TECHNICAL SPECIFICATIONS FSH1BG Series FEATURES and BENEFITS Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities 1 The iq Drive heat pump system features modulating compressor
More informationField Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.
Description: The High Efficiency Series air handlers are engineered to achieve or exceed today s demanding energy rating requirements. Specifically designed for horizontal mounting into a furred down ceiling.
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.
FORM NO. AFJ-222 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*16C SERIES Efficiencies up to 16 SEER/13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to
More informationSolenoid Valves, one - or two step, on/off ICLX
MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid Valves, one - or two step, on/off ICLX 32-150 ICLX servo valves belong to the ICV (Industrial Control Valve) family. ICLX are used in suction lines
More informationSolenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Solenoid valves, two-step on/off PMLX REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3
More informationPressure Dump Valve Service Kit for Series 2300 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit
More informationMAINLINE MLA14 AIR CONDITIONERS
FORM NO. AML-220 Supersedes Form No. PTZ-789 MAINLINE AIR CONDITIONERS Efficiencies up to 16 /13 Nominal Sizes 1.5-5 Ton [5.28 TO 17.6 KW] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.
FORM NO. AFJ-220 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*14C SERIES Efficiencies up to 16 S/13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7
More informationFluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS
Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS HOSE REELS SIGNATURE SERIES H O S E S R E E L S FEATURES & BENEFITS Eight position locking precision die cast latch mechanism, with secure
More informationDual position solenoid valve Type ICSH 25-80
Data sheet Dual position solenoid valve Type ICSH 25-80 ICSH dual position solenoid valve belongs to the ICV family and consists of an ICV housing, an ICS insert together with an ICSH top cover with 2
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.
FORM NO. AFJ-221 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*13C SERIES Efficiencies 13-15.5 SEER/11.5-13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7
More informationSystem Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner
System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner Mohammad Khawaldeh Director, Unitary & Applied Product Units Presentation Outline Objectives Challenges Base
More informationINSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL
INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL 8059601 To be used with MST Model 8050501 Ambient Air Pump 7/12/05 2 TABLE OF CONTENTS GENERAL INFORMATION... 3 WARNING...4,5 UNPACKING AND AFTERCOOLER ASSEMBLY
More informationDucted Reverse Cycle Air Conditioning of Distinction
Ducted Reverse Cycle Air Conditioning of Distinction Transforming global energy-efficiency into an art form! The Braemar advantage Braemar ducted reverse cycle air conditioners are brought to you by Seeley
More informationPressure Dump Valve Service Kit for Series 3000 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator
More informationTECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY
Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationINDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES
INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts
More informationFlow Sensors & Hydrometers Specification Sheet
Baseline Flow s and Hydrometers Baseline s smart flow sensors and hydrometers are two-wire ready flow measurement and control devices that are pre-programmed with the correct K and Offset values. In addition,
More information3/8" Dr. Air Butterfly Impact Wrench
8192106 3/8" Dr. Air Butterfly Impact Wrench Owner s Manual Read and understand all instructions before use. Retain this manual for future reference. Specifications Construction: Polished aluminum and
More informationInstructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.
027R9782 Instructions Control Solution ICF 20-4, ICF 25-4, ICF 32-4. ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position ICF xx-4 ICF xx-6 ICF xx-4 / ICF xx-6 with ICM ICM 027R9782
More informationGas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Gas powered stop valves, type GPLX 80-150 REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical leaflet Gas powered stop valves, type GPLX 80-150 Contents Page Introduction........................................................................................3
More informationTECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13
Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationQuick Start SunPump Install
Quick Start SunPump Install Make A Plan Visualize the complete install. The first step is to commit a plan to paper by a simplified sketch. Where is the best location for the Panels? What is the preferred
More informationGas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling
PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow models HEAT EXCHANGER Aluminized steel tapered design primary heat exchanger with crimped construction for long
More informationATD LB PRESSURE BLASTER INSTRUCTION MANUAL
ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off
More informationThe Shand & Jurs Model Vapor Guard Tank Blanketing Valve
Lower maintenance due to fewer parts Occupies less space, less stress to tank Teflon is inert to most chemicals; extends service life Simplifies and lowers maintenance cost Optimizes flow of blanketing
More informationValve Station ICF 15, 20 and 25
Installation Guide Valve Station ICF 15, 20 and 25 027R9782 Installation ICF xx-4 ICF xx-6 ICF xx-4 / ICF xx-6 + 027R9782 1a 1b 1c Welding TIG/MIG/SMAW Gas welding Danfoss M27L0049_1 2 3 Danfoss A/S (RC-MDP/MWA),
More informationFood Service Industry Hose
Food Service Industry Hose Intro... -2 Clearforce - NR... -3 Clearforce - R... -4 Aquaforce... -5 rey Food Transfer... -6 Lion Food Transfer... -7 Dry Bulk Food Discharge... -8 EATON Industrial Hose and
More informationV48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings
Installation Instructions V48 Issue Date 08/30/01 V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings Application IMPORTANT: The V48 Series 3-Way Pressure-Actuated Water-Regulating
More informationSeries V48. 3-Way Pressure Actuated Modulating Valves. Product Bulletin. Features. Pressure balanced design. Free movement of all parts
Series V48 -Way Pressure Actuated Modulating Valves Product Bulletin These Water Valves are especially designed for condensing units cooled either by atmospheric or forced draft cooling towers. They may
More informationVariable Area Flow Meters
Variable Area Flow Meters Over sixty years of variable area meter expertise Brooks started designing and manufacturing variable area (VA) meters, also referred to as rotameters, in 1946. Now, with more
More informationGas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited
PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow models HEAT EXCHANGER Aluminized steel primary heat exchanger with crimped non-welded construction Stainless steel
More informationTECHNICAL DATA. Q= Cv S
Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationMAINTENANCE AND OPERATING MANUAL
MAINTENANCE AND OPERATING MANUAL Cyclone condensate separator Type ASA EN EN Maintenance and operating manual Purpose and appropriate use Dear Customer, thank you for choosing our product. In order to
More information36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS
36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING
More informationWater Cooling and Evaporator Coils. Types HI-F5 and E-F5. Catalog 411-9
Water Cooling and Evaporator Coils Types HI-F5 and E-F5 Catalog 411-9 Table of Contents Introduction.... 3 HI-F5 and E-F5 Water Cooling and Evaporator Coils 3 Daikin SelectTools for Contractor Coils...3
More informationR600 and HSRL Series Instruction Manual
Instruction Manual MCK 2141 November 2009 R600 and HSRL Series Instruction Manual! Warning Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated
More informationInert Air (N2) Systems Manual
INSTRUCTION MANUAL Inert Air (N2) Systems Manual N2-MANUAL 2.10 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. GENERAL INFORMATION Positive pressure nitrogen gas pressurizing
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS HIGH ALTITUDE APPLICATION CONVERSION INSTRUCTION HIGH EFFICIENCY GAS FURNACES 1PS0306 / 1PS0307 / 1PS0308 / 1PS0309 / 1PS0901 / 1PS0902 / 1PS0903 FOR USE WITH MODELS:
More informationSeries V47 Temperature Actuated Modulating Valves
PSC0302 European Refrigeration Controls Catalogue Catalog Section 7 Product Bulletin V47 Series V47 Temperature Actuated Modulating Valves Introduction The V47 modulating water valves regulate the flow
More informationR-410A 50% R-32 50% R-125.
R-410A R-410A Facts Ozone friendly- No Chlorine Replacement for R-22, NOT a drop in! Higher Pressure Range-50 to 75% higher than R-22 Requires Special Lubricants R-410A It s a Blended Refrigerant. 50%
More informationMODEL: SA13. Air Conditioners. Sure Comfort SA13. Air Conditioners
15.5 MODEL: SA13 Air Conditioners FORM NO. ASC-221 REV. 1 Sure Comfort SA13 Air Conditioners Efficiencies 13-15.5 S/11.5-13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5
More informationGETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL
GETZ EQUIPMENT INNOVATORS CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL GETZ EQUIPMENT INNOVATORS PEKIN, ILLINOIS, U.S.A. PHONE: (888) 747-4389 FAX: (309) 495-0625 Limited Warranty
More informationManual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering
Manual Bypass Feeder Chemical Addition and Filtering Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 918-686-6211 Fax: 918-686-6212 www.advantagecontrols.com
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0501 FOR USE WITH 95% MODELS: TG9S, GG9S (130,000 BTU ONLY) FOR USE WITH 80% MODELS: TG(8,L)S, GG(8,L)S (130,000
More informationVB-7263 Series. Application. Features. Applicable Literature
TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com VB-7263 Series 1/2" to 2" Screwed NPT Stainless Steel Trim with Teflon Disc Stem Up Closed, Two-Way Valves General Instructions
More informationTECHNICAL DATA. Q = C v P S
Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationVB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions
VB-7213 Series 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions Application VB-7213 series single seat, stem up open, two-way valves control water from 20 to 281 F (-7 to 138 C)
More informationDISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES
DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES THIS REPORT WAS PREPARED BY THE ORGANIZATION(S) NAMED BELOW. NEITHRE THE ORGANIZATION(S) BELOW, NOR ANY PERSON ACTING ON BEHALF OF THEM: (A) MAKES
More informationPORTABLE 5 GALLON AIR TANK ASSEMBLY & OPERATING INSTRUCTIONS
PORTABLE 5 GALLON AIR TANK MODEL 472 ASSEMBLY & OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com TO PREVENT SERIOUS INJURY, READ AND UNDERSTAND
More informatione G) GOVERNOR t,5 ii:i! Line Pressure Regulators
Line Pressure Regulators @ - c - e G) t,5 ii:i! 1rlr1t APPLICATION NOTES 1rlr1t A. The Governor regulator is ANSI Z21.80a and ANSI Z21.18 certified for vent limited installations (indoor installations
More informationPRO-50 Instrument Supply Regulator
Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits
More informationV248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants
Code No. LIT-19576 Issued June 22, 21 V248 Series -Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants Description The V248 Series -Way Pressure-Actuated Water-Regulating Valves
More informationCapacity regulator (hot gas bypass)
MAKING MODERN LIVING POSSIBLE Capacity regulator (hot gas bypass) TUH/TCHE/ Technical brochure Contents Page Introduction........................................................................................3
More informationTECHNICAL DATA OBSOLETE
April 9, 2009 Preaction 326a 1. DESCRIPTION Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilizing the Viking G-4000P Deluge Valve. The small profi le, lightweight,
More informationV46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings
Installation Instructions V46 Issue Date 11//1 V46 Series -Way Pressure-Actuated Water-Regulating Valves With Union Fittings Application IMPORTANT: The V46 Series -Way Pressure-Actuated Water-Regulating
More informationPAPR Flow Tester. instructions. part no WARNING
PAPR Flow Tester part no. 488903 instructions WARNING This manual, including warnings and cautions inside, must be carefully read and followed by all persons who use or maintain the product, including
More informatione G) GOVERNOR t,5 ii:i! Line Pressure Regulators
Line Pressure Regulators @ - c - e G) t,5 ii:i! 1rlr1t APPLICATION NOTES 1rlr1t A. The Governor regulator is ANSI Z21.80a and ANSI Z21.18 certified for vent limited installations (indoor installations
More informationR122H, R222, R232A, and R232E Series Instruction Manual
Instruction Manual MCK 2156 R122H, R222, R232A, and R232E Series October 2012 R122H, R222, R232A, and R232E Series Instruction Manual Failure to follow these instructions or to properly install and maintain
More informationOwner's Manual Sealweld SuperSeal II Pump
Owner's Manual Sealweld SuperSeal II Pump By Sealweld Corporation Technical Specification Sealweld SuperSeal II Pump One (1) High Pressure Sealant/Lubricant SuperSeal II Pump: 100:1 Ratio with 10,000 psi
More informationTank Blanketing Pressure Regulators RHPS Series
www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22
More informationCash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified
Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot
More information3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.
3" UC-3000 (76.2 mm) Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual DOUBLE E COMPANY, INC. 319 Manley Street, West Bridgewater, MA 02379 U.S.A. Tel: (508) 588-8099 /
More informationinstallation instructions
installation instructions GAS CONVERSION KIT PROPANE-TO-NATURAL P/N 315572-71201 4GAD 6GAD Cancels: IIK 4G-50-4 IIK 4G-50-5 7/15/91 NOTE: Read the entire instructions before starting the installation.
More informationV248 Series 3-Way Pressure-Actuated. Water-Regulating Valves for High-Pressure
V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants The V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants regulate water
More informationELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS
PRODUCT SPECIFICATIONS AIR CONDITIONERS EL16XC1 ELITE Series R-410A Bulletin 210758 November 2017 Supersedes August 2017 SEER up to 17.90 1.5 to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh MODEL NUMBER
More informationSDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual
SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual 8 Executive Drive P.O. Box 2105 Toms River, NJ 08754 (732) 244-0010 (800) 337-3762 fax (732) 244-8140 www.permapure.com info@permapure.com
More informationBall Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65
Data Sheet 819346-02 Issue Date: 05/17 Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300, 50, 65 UNA 45hl MAX, UNA 46hl MAX, UNA 46Ahl MAX UNA 45v MAX with cover for mounting electrode
More informationTechnical data. Back pressure limit: 27.5% of set pressure. Capacity certification: ASME Boiler & Pressure Vessel Code Section I and VIII
VALVES & CONTROLS CROSBY SAFETY VALVES H ig h C a p a c it y, S t e a m S e r v ic e, F la n g e d S t e e l S a f e t y V a lv e Introduction Crosby Style HSL is a full nozzle reaction type safety valve
More informationModel 8800A. Pressure Relief and Vacuum Breaker Valve with Flame Arrester
MODEL 8800A USED ON DIGESTERS AND GAS HOLDERS A combination of the Groth Model 1200A pressure relief and vacuum breaker vent and Groth Model 7618 flame arrester make up the unit. The superior Buna-N seating
More informationInstallation Instructions
Installation Instructions BW Seals Uniseal Series Cartridge metal bellows single and dual seals Experience In Motion Description The Uniseal metal bellows seal series consists of: Uniseal I - Single seals
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated
More informationGlycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers
Glycol Systems Engineering Manual 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Stulz Air Technology Systems, Inc. Table of Contents Section - 1 Table
More informationC Lite CAD SERIES. ACS Approved. Patented CAD-2 diaphragm technology. Rugged copolymer polypropylene base. Quality brass air stem with o-ring seal
2 C Lite CAD SERIES Patented CAD-2 diaphragm technology Unique 3 piece construction Reinforced Plastic Connection Durable continuous strand fiberglass sealed with epoxy resin NSF Standard 61, CE/PED, WRAS,
More informationStandard Operating and Maintenance Instructions for Pumping System Model PS-90
Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075
More informationModels: C62/63/64-A/D
Installation & Service C62-991-24A3 Models: C62/63/64-A/D Diaphragm Bypass Pressure Regulating Valves IMPORTANT Record your pump model number and serial number here for easy reference: Model No. Serial
More informationSetup Guide for your HVO Naked Drone
Setup Guide for your HVO 60 + 60 Naked Drone 1 The Big Picture 1. Choose The System Location 2. Get the Power Ready 3. Get an Approved Oxygen Regulator 4. Get the Tools You ll Need 5. Unpack the crate
More informationVBS-9263 Series. Application. Features. Applicable Literature
TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com VBS-9263 Series 1/2" and 3/4" Screwed NPT 316 Stainless Steel Stem Up Closed, Two-Way Valves General Instructions Application
More information