FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities
|
|
- Hugo Cooper
- 5 years ago
- Views:
Transcription
1 TECHNICAL SPECIFICATIONS FSH1BG Series FEATURES and BENEFITS Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities 1 The iq Drive heat pump system features modulating compressor technology and variable speed indoor and outdoor fan motors. This system is controlled from a two stage cooling and heating heat pump thermostat. The system has the capability of adding up to 18% of additional cooling/heating above the rated capacity. The B6VMAX air handler has de-humidification capabilities from the thermostat or duct mounted humidistat A B C D E F G H I 9 iq Drive: Inverter driven Samsung rotary compressor provides five capacities in modulating operation from a two stage thermostat. Interface control board: Two digit LED provides system operation, status and diagnostic troubleshooting information. System Control: Utilizes a patented capacity control algorithm to select the optimum system capacity level. System Protection: Internal controls monitor system operation to protect the inverter drive and compressor. Cooling operating temperature range: 50 F to 125 F. Locks out heat pump heating: below 0 F. Adaptive demand defrost: Provides additional energy savings in heating by defrosting only when necessary. Five Minute Restart Time Delay: When the unit shuts down, a delay keeps the unit from restarting, eliminating the highest cause for compressor failure. Suction Accumulator: Protection from liquid flood back and future compressor failures. Compressor and Component Access: Designed to makexxxxxx servicing easier for the contractor, hinge access panels are provided to all controls and the compressor. High Efficiency with the low Sound Levels: Up to 19 SEER with sound ratings of depending upon operating conditions. Compressor Sound Blanket: Engineered to significantly reduce unwanted compressor noise. Variable Speed Condenser Motor and Swept-Wing Fan Blade: A heavy duty brushless DC motor for long lasting reliability and engineered to provide quiet operation. Requires no maintenance and is completely protected from rain and snow. Common Suction Service Port: This port allows the contractor to read the suction pressure in all modes of operation without removing any panels, saving time and increasing serviceability. Discharge muffler: Reduces compressor noise and vibration. High Pressure Switch: Protects against abnormally high system pressures. Auto-reset feature prevents nuisance service visits. Low Pressure Switch: Protects against loss of system refrigerant charge. Liquid Line Filter Drier: Included with unit, field installed. Copper Tube / Aluminum Fin Coils: outdoor coils are designed to optimize heat transfer, and increase durability and reliability. Composite Base Pan: Absorbs sound and is corrosion MATERIAL: resistant. Composite pan is also stronger and lighter than steel. Designed usingfinish: galvanized steel: With a polyester urethane coat finish, it passes hours of salt spray TITLE: per ASTM Std. AUTH. NO. 950 DATE: ERROR!:Auth. No ERROR!:Auth Date B117. ENGINEERING: DRAWING NO. REV. One Piece Top/Orifice: Designed for maximum airflow and DRAFTER: MONARCH_B 1:4 1 OF 1 D quiet operation. Removable Top Grille Assembly: Allows ease of service from the top without disconnecting fan motor leads. Servicer-Friendly Jacket: Side panels can be easily removed and replaced without removing the top grill THIRD ANGLE PROJECTION UNLESS OTHEWISE SPECIFIED DIMENSIONS ARE IN INCHES J TOLERANCE UNLESS OTHERWISE SPECIFIED FOR HOLE DIAMETERS UP TO , , OVER TOLERANCE UNLESS OTHERWISE SPECIFIED FOR LINEAR DIMENSIONS AND SQUARENESS IS.031 K REV. REVISION RECORD 17 PART NUMBER SHOWN IS: DATE BY ENGR. PCA TOLERANCE UNLESS OTHERWISE SPECIFIED FOR ANGLE IS 2 0 PHOENIX PKWY O'FALLON, MO THIS DRAWING IS THE PROPERTY OF NORDYNE ENGINEERING. ALL USE IS FORBIDDEN EXCEPT ON ITS WRITTEN CONSENT PART(S) MUST COMPLY WITH ENGINEERING REQUIREMENT(S) SIZE: SCALE: SHEET:
2 2
3 MODEL IDENTIFICATION CODES F S H 1 B G 4 C V R X 24 K Jacket Style Voltages C - 208/ D E - 220/ G - 3/ K - 208/ Split System A - Air Conditioner H - Heat Pump Design Series Size (MBTU) B - Brazed Q - Quick Connect D - 13 SEER E - 14 SEER F - 16 SEER G SEER X - Export Refrigerant 4 - R-4a Compressor S - Scroll R - Rotary E - Recip Stages 1 - Single 2 - Two V - Inverter M - Micro-Channel C - Copper Coil Metering Device N - None X - TXV P - Piston E - EXV DIMENSIONS AIR CONDITIONER OUTDOOR SECTION FSH1BG 24K 36K 48K K H W D Air Discharge Allow Adequate Clearance for Airflow A W B D C D H E F G H I ELGNA DRIHT NOITCEJORP :LAIRETAM - 3
4 PHYSICAL AND ELECTRICAL SPECIFICATIONS / OUTDOOR UNITS Up to 19 SEER Ultra High Efficiency Single Phase Unit Size: 24K Volts-Cycles-Phase Total Amps Delay Fuse Max. (2) Min. Circuit Ampacity (1) Electrical Data Fan Motor Component Data Compressor Data Service Valves Installation Refrigerant Vapor Line Size (All liquid lines 3/8 OD) Weight, lbs. (approximate) Sound Level db Type Amps HP RLA LRA Liquid Side Vapor Side 0-24 ft. equiv ft. equiv ft. equiv. (4) - 0 ft. equiv. (4) Net Ship Minimum Maximum (1) Operating Voltage Range: 187 vac min. to 253 vac max. (2) HACR Type circuit breakers may be used. (3) Additional charge for longer line sets as follows (with 3/8 liquid lines): 3/4 vapor line: oz per additional foot 7/8 vapor line: oz per additional foot 1-1/8 vapor line: oz per additional foot Minimum outdoor temperature for heating is. Minimum outdoor temperature for cooling is 5. (4) Refrigerant Tubing Limitations-The compressor manufacturer imposes a maximum equivalent line set length of 0 ft. Furthermore, vertical elevation shall not exceed 50 ft. (5) For additional charging instructions please refer to the QRD. See current AHRI Directory for certified combinations and ratings. COPPER WIRE SIZE AWG (1% Voltage Drop) Supply Wire Length-Feet Supply Circuit Ampacity Wire Size based on N.E.C. for type copper conductors. 4 1/3.5 N/A 3/8 3/4 3/4 3/4 7/8 1-1/ K 48K 208/ BLDC 1/3 1/3 1 N/A N/A 3/8 3/8 7/8 7/8 7/8 7/8 7/8 1-1/8 1-1/8 1-1/8 1-1/8 1-1/ K / N/A 3/8 7/8 7/8 1-1/8 1-1/8 1-1/
5 Panel Removal and Replacement Instructions Removing Panels: Remove screws. Pull up on panel. Rotate bottom of panel out. Pull panel off. Reinstalling Panels: 1. Place panel back in towards top of unit. 2. Rotate bottom of panel inwards. 3. Push panel down until it fills gap at bottom of unit. 4. Replace screws. 5
6 SYSTEM CAPACITIES AND MATCHES Up to 19 SEER Ultra High Efficiency Single Phase Model Number FSH1BG4CVRX24K FSH1BG4CVRX24K FSH1BG4CVRX24K FSH1BG4CVRX24K FSH1BG4CVRX36K FSH1BG4CVRX36K FSH1BG4CVRX36K FSH1BG4CVRX36K FSH1BG4CVRX36K FSH1BG4CVRX36K FSH1BG4CVRX48K FSH1BG4CVRX48K FSH1BG4CVRX48K FSH1BG4CVRX48K FSH1BG4CVRXK FSH1BG4CVRXK FSH1BG4CVRXK FSH1BG4CVRXK FSH1BG4CVRXK FSH1BG4CVRXK Coil ModelNumber B6VMAX24K-B C6B(A,H)-X26(C,U)-B C6B(A,H)-X26(C,U)-B C6B(A,H)-X26(C,U)-B B6VMAX36K-B C6B(A,H)-X36(C,U)-B C6B(A,H)-X36(C,U)-B C6B(A,H)-X36(C,U)-B C6B(A,H)-X36(C,U)-C C6B(A,H)-X36(C,U)-C B6VMAX48K-C C6B(A,H)-X48(C,U)-C C6B(A,H)-X48(C,U)-C C6B(A,H)-X48(C,U)-C B6VMAXK-C C6B(A,H)-X(C,U)-C C6B(A,H)-X(C,U)-C C6B(A,H)-X(C,U)-C C6B(A,H)-X(C,U)-D C6B(A,H)-X(C,U)-D ModelNumber FG7S(*)-B+(*)SHE FG7T(*)-VB MB7VM-10-B FG7S(*)-B+(*)SHE FG7T(*)-VB MB7VM-10-B FG7S(*)-C+(*)SHE FG7T(*)-VC FG7S(*)-C+(*)SHE FG7T(*)-VC MB7VM-2000-C FG7S(*)-C+(*)SHE FG7T(*)-VC MB7VM-2000-C FG7S(*)-D+(*)SHE FG7T(*)-VD Cap 24,0 24,400 24,400 24,0 34, 34,0 34,0 34, 34, 34, 44,000 44,000 44,000 44,000 53,000 53,000 53,000 53,000 53,000 53,000 SEER EER CFM 2nd Stg CFM Heat 47F HSPF 1st Stg ,400 22,200 22,200 22,400 34,400 34,0 34,0 34,400 34,200 34,200 44,000 44,200 44,200 44,000 56,000 56,000 56,000 56,000 56,000 56, Cooling Note: Conditions for Nominal Capacity rating are F dry bulb temperature, F wet bulb temperature (approximately 51% RH) indoors, outdoor ambient temperature. Minimum outdoor temperature for cooling is 5. Heating Note: Conditions for Nominal Capacity rating are 7 dry bulb temperature indoors, F dry bulb temperature, 43 F wet bulb temperature outdoors. Minimum outdoor temperature for heating is. See current AHRI Directory for certified combinations and ratings. 6
7 COOLING EXPANDED RATINGS with Variable Speed AIR HANDLER FSH1BG4CVRX24K with B6VMAX24K-B First Stage (Low Speed C1) Cooling F FSH1BG4CVRX24K with B6VMAX24K-B Second Stage (Nominal High Speed C4) Cooling 5 F FSH1BG4CVRX24K with B6VMAX24K-B Second Stage (Boost Speed C5) Cooling 5 F E.D.B. = Entering dry bulb E.W.B. = Entering wet bulb = Total Capacity = Sensible Capacity = Kilo Watts NOTE: For outdoor temperature ranges that are blank, values are omitted because the interface controller may reduce compressor speed for protection. 7
8 COOLING EXPANDED RATINGS with Variable Speed AIR HANDLER (CONT.) FSH1BG4CVRX36K with B6VMAX36K-B First Stage (Low Speed C1) Cooling 0 5 F F FSH1BG4CVRX36K with B6VMAX36K-B Second Stage (Nominal High Speed C4) Cooling F FSH1BG4CVRX36K with B6VMAX36K-B Second Stage (Boost Speed C5) Cooling E.D.B. = Entering dry bulb E.W.B. = Entering wet bulb = Total Capacity NOTE: For outdoor temperature ranges that are blank, values are omitted because the interface controller may reduce compressor speed for protection. 8 = Sensible Capacity = Kilo Watts
9 COOLING EXPANDED RATINGS with Variable Speed AIR HANDLER (CONT.) FSH1BG4CVRX48K with B6VMAX48K-C First Stage (Low Speed C1) Cooling F FSH1BG4CVRX48K with B6VMAX48K-C Second Stage (Nominal High Speed C4) Cooling F FSH1BG4CVRX48K with B6VMAX48K-C Second Stage (Boost Speed C5) Cooling E.D.B. = Entering dry bulb F E.W.B. = Entering wet bulb = Total Capacity = Sensible Capacity = Kilo Watts NOTE: For outdoor temperature ranges that are blank, values are omitted because the interface controller may reduce compressor speed for protection. 9
10 COOLING EXPANDED RATINGS with Variable Speed AIR HANDLER (CONT.) FSH1BG4CVRXK with B6VMAXK-C First Stage (Low Speed C1) Cooling F FSH1BG4CVRXK with B6VMAXK-C Second Stage (Nominal High Speed C4) Cooling F FSH1BG4CVRXK with B6VMAXK-C Second Stage (Boost Speed C5) Cooling F E.D.B. = Entering dry bulb E.W.B. = Entering wet bulb = Total Capacity = Sensible Capacity = Kilo Watts NOTE: For outdoor temperature ranges that are blank, values are omitted because the interface controller may reduce compressor speed for protection.
11 COOLING EXPANDED RATINGS with COIL AND Variable Speed Furnace First Stage (Low Speed C1) Cooling FSH1BG4CVRX24K with C6BH-X26C-B and FG7-VB F Second Stage (Nominal High Speed C4) Cooling FSH1BG4CVRX24K with C6BH-X26C-B and FG7-VB 0 5 F Second Stage (Boost Speed C5) Cooling FSH1BG4CVRX24K with C6BH-X26C-B and FG7-VB 0 5 F
12 COOLING EXPANDED RATINGS with COIL AND Variable Speed Furnace (CONT.) First Stage (Low Speed C1) Cooling FSH1BG4CVRX36K with C6BH-X36C-C and FG7-VC 0 5 F Second Stage (Nominal High Speed C4) Cooling FSH1BG4CVRX36K with C6BH-X36C-C and FG7-VC 50 5 F Second Stage (Boost Speed C5) Cooling FSH1BG4CVRX36K with C6BH-X36C-C and FG7-VC F
13 COOLING EXPANDED RATINGS with COIL AND Variable Speed Furnace (CONT.) First Stage (Low Speed C1) Cooling FSH1BG4CVRX48K with C6BH-X48C-C and FG7-VC F Second Stage (Nominal High Speed C4) Cooling FSH1BG4CVRX48K with C6BH-X48C-C and FG7-VC 5 F Second Stage (Boost Speed C5) Cooling FSH1BG4CVRX48K with C6BH-X48C-C and FG7-VC 5 F
14 COOLING EXPANDED RATINGS with COIL AND Variable Speed Furnace (CONT.) First Stage (Low Speed C1) Cooling FSH1BG4CVRXK with C6BH-XC-D and FG7-VD 5 F Second Stage (Nominal High Speed C4) Cooling FSH1BG4CVRXK with C6BH-XC-D and FG7-VD 5 F Second Stage (Boost Speed C5) Cooling FSH1BG4CVRXK with C6BH-XC-D and FG7-VD 5 F
15 HEATING EXPANDED RATINGS WITH Variable Speed AIR HANDLER FSH1BG4CVRX24K with B6VMAX24K-B First Stage (Low Speed H1) Heating (nominal) E.D.B COP COP COP COP COP COP COP COP COP FSH1BG4CVRX24K with B6VMAX24K-B 2 Ton Second Stage (Nominal High Speed H4) Heating (nominal) 0 E.D.B COP COP COP COP COP COP COP COP COP FSH1BG4CVRX24K with B6VMAX24K-B 2 Ton Second Stage (Boost Speed H5)Heating (nominal) E.D.B COP COP COP COP COP COP COP COP COP = Total Capacity COP = Coefficient of Performance = Kilo Watts 15
16 HEATING EXPANDED RATINGS WITH Variable Speed AIR HANDLER (CONT.) FSH1BG4CVRX36K with B6VMAX36K-B First Stage (Low Speed H1) Heating Outdoor Temperature: (nominal) 0 E.D.B COP COP COP COP COP COP COP COP COP FSH1BG4CVRX36K with B6VMAX36K-B 3 Ton Second Stage (Nominal High Speed H4) Heating Outdoor Temperature: (nominal) 50 E.D.B COP COP COP COP COP COP COP COP COP FSH1BG4CVRX36K with B6VMAX36K-B 3 Ton Second Stage (Boost Speed H5) Heating Outdoor Temperature: (nominal) 50 E.D.B COP COP COP COP COP COP COP COP COP = Total Capacity 16 COP = Coefficient of Performance = Kilo Watts
17 HEATING EXPANDED RATINGS WITH Variable Speed AIR HANDLER (CONT.) FSH1BG4CVRX48K with B6VMAX48K-C First Stage (Low Speed H1) Heating Outdoor Temperature: COP COP COP COP COP COP COP COP COP FSH1BG4CVRX48K with B6VMAX48K-C 4 Ton Second Stage (Nominal High Speed H4) Heating Outdoor Temperature: COP COP COP COP COP COP COP COP COP FSH1BG4CVRX48K with B6VMAX48K-C 4 Ton Second Stage (Boost Speed H5) Heating Outdoor Temperature: = Total Capacity COP COP COP COP COP COP COP COP COP COP = Coefficient of Performance = Kilo Watts 17
18 HEATING EXPANDED RATINGS WITH Variable Speed AIR HANDLER (CONT.) FSH1BG4CVRXK with B6VMAXK-C First Stage (Low Speed H1) Heating Outdoor Temperature: COP COP COP COP COP COP COP COP COP FSH1BG4CVRXK with B6VMAXK-C 5 Ton Second Stage (Nominal High Speed H4) Heating Outdoor Temperature: 1650 COP COP COP COP COP COP COP COP COP FSH1BG4CVRXK with B6VMAXK-C 5 Ton Second Stage (Boost Speed H5) Heating Outdoor Temperature: 1650 COP COP COP COP COP COP COP COP COP = Total Capacity 18 COP = Coefficient of Performance = Kilo Watts
19 HEATING EXPANDED RATINGS WITH COIL and Variable Speed Furnace First Stage (Low Speed H1) Heating FSH1BG4CVRX24K with C6BH-X26C-B and FG7-VB COP COP COP COP COP COP COP COP COP Second Stage (Nominal High Speed H4) Heating FSH1BG4CVRX24K with C6BH-X26C-B and FG7-VB COP COP COP COP COP COP COP COP COP Second Stage (Boost Speed H5) Heating FSH1BG4CVRX24K with C6BH-X26C-B and FG7-VB COP COP COP COP COP COP COP COP COP
20 HEATING EXPANDED RATINGS WITH COIL and Variable Speed Furnace (CONT.) First Stage (Low Speed H1) Heating FSH1BG4CVRX36K with C6BH-X36C-C and FG7-VC 0 COP COP COP COP COP COP COP COP COP Second Stage (Nominal High Speed H4) Heating FSH1BG4CVRX36K with C6BH-X36C-C and FG7-VC 50 COP COP COP COP COP COP COP COP COP Second Stage (Boost Speed H5) Heating FSH1BG4CVRX36K with C6BH-X36C-C and FG7-VC COP COP COP COP COP COP COP COP COP
21 HEATING EXPANDED RATINGS WITH COIL and Variable Speed Furnace (CONT.) First Stage (Low Speed H1) Heating FSH1BG4CVRX48K with C6BH-X48C-C and FG7-VC COP COP COP COP COP COP COP COP COP Second Stage (Nominal High Speed H4) Heating FSH1BG4CVRX48K with C6BH-X48C-C and FG7-VC COP COP COP COP COP COP COP COP COP Second Stage (Boost Speed H5) Heating FSH1BG4CVRX48K with C6BH-X48C-C and FG7-VC COP COP COP COP COP COP COP COP COP
22 HEATING EXPANDED RATINGS WITH COIL and Variable Speed Furnace (CONT.) First Stage (Low Speed H1) Heating FSH1BG4CVRXK with C6BH-XC-D and FG7-VD COP COP COP COP COP COP COP COP COP Second Stage (Nominal High Speed H4) Heating FSH1BG4CVRXK with C6BH-XC-D and FG7-VD 1650 COP COP COP COP COP COP COP COP COP Second Stage (Boost Speed H5) Heating FSH1BG4CVRXK with C6BH-XC-D and FG7-VD COP COP COP COP COP COP COP COP COP
23 23
24 GENERAL TERMS OF LIMITED WARRANTY Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty. For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (04/2017) 782E-0417 Powered by TCPDF ( Trademark Frigidaire is a registered trademark used under license from Frigidaire International Company, U.S.A. Nortek Global HVAC, LLC. All Rights Reserved.
AIR CONDITIONERS WA14**W SERIES
FORM NO. A66-225 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light
More informationAIR CONDITIONERS WA14 SERIES
FORM NO. A66-220 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light
More informationMAINLINE MLA14 AIR CONDITIONERS
FORM NO. AML-220 Supersedes Form No. PTZ-789 MAINLINE AIR CONDITIONERS Efficiencies up to 16 /13 Nominal Sizes 1.5-5 Ton [5.28 TO 17.6 KW] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.
FORM NO. AFJ-222 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*16C SERIES Efficiencies up to 16 SEER/13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.
FORM NO. AFJ-220 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*14C SERIES Efficiencies up to 16 S/13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.
FORM NO. AFJ-221 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*13C SERIES Efficiencies 13-15.5 SEER/11.5-13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7
More informationVARIABLE SPEED AIR CONDITIONERS
FORM NO. AFJ-224 Supersedes Form No. AFJ-222 VARIABLE SPEED AIR CONDITIONERS FO*20C SERIES Efficiencies up to 20 SEER/13 EER Nominal Sizes 2, 3, 4 & 5 Ton [7.03, 10.6, 14.06 & 17.6 kw] Cooling Capacities
More informationMAINLINE MLP14**A HEAT PUMPS
FORM NO. PML-806 REV. 2 Supersedes Form No. PTZ-789 MAINLINE HEAT PUMPS Efficiencies: 15 SEER/12.5 EER 9 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to
More informationFMU4X, FMC4X FMU4P, FMC4P
ENVIRONMENTALLY SOUND REFRIGERANT FMU4X, FMC4X FMU4P, FMC4P Product Specifications HORIZONTAL FAN COILS FMU4P and FMC4P 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2 and 2 1/2 Tons ALL MODELS Horizontal
More information4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP
4HP15 PRODUCT SPECIFICATIONS 15 SPLIT SYSTEM HEAT PUMP FORM NO. 4HP15-100 (12/2017) FEATURES AND BENEFITS R410A Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for
More informationELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS
PRODUCT SPECIFICATIONS AIR CONDITIONERS EL16XC1 ELITE Series R-410A Bulletin 210758 November 2017 Supersedes August 2017 SEER up to 17.90 1.5 to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh MODEL NUMBER
More informationAE R1 February 2015
February 2015 CoreSense Diagnostics for Copeland Scroll UltraTech Air Conditioning Compressors TABLE OF CONTENTS Safety Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to
More informationField Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.
Description: The High Efficiency Series air handlers are engineered to achieve or exceed today s demanding energy rating requirements. Specifically designed for horizontal mounting into a furred down ceiling.
More informationEvaporator (DX) Freon Applications 1 12 Tons MHF
Evaporator (DX) Freon Applications 1 12 Tons > > Used For small to medium freon applications The Global Leader In Heat Exchange Technology With seven decades of experience and commitment to total client
More informationProduct Data. CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil --- Cased and Uncased Upflow, Downflow CAPVP / CARVP
CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil Cased and Uncased Upflow, Downflow Product Data CAPVP / CARVP A06001 A06002 CAPVU / CARVU The CAPVP, CARVP, CAPVU, and CARVU evaporator coils incorporate
More informationRuud Achiever Series Heat Pump
Heat Pumps Ruud Achiever Series Heat Pump RP14**F Series Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: up to 14 SEER/11.5 EER/8.2 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing
More informationMODEL: SA13. Air Conditioners. Sure Comfort SA13. Air Conditioners
15.5 MODEL: SA13 Air Conditioners FORM NO. ASC-221 REV. 1 Sure Comfort SA13 Air Conditioners Efficiencies 13-15.5 S/11.5-13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationProduct Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)
CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE Product Data (3619, 4823, 6025) A06009 A07904 The CAPMP and CARMP evaporator coils incorporate proven standards for reliable system operation and
More informationModel 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.
EVAPORATOR COILS A COIL UNCASED R 22 or R 410A SYSTEMS 1 5 Tons WEAU Certification applies only when the complete system is listed with ARI ISO 9001:2000 REGISTERED R 410A R 22 Size Shipping Weight Size
More information4SCU16LS PRODUCT SPECIFICATIONS 16 SEER SPLIT SYSTEM ENHANCED AIR CONDITIONING DESIGN COMPONENTS WARRANTY COMPRESSOR CABINET COILS
PRODUCT SPECIFICATIONS 16 S SPLIT SYSTEM ENHANCED AIR CONDITIONING FORM NO. -100 (06/2014) DESIGN Designed for ambients up to 125 F COMPONENTS Service valves positioned for quick installation and easy
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14 SEER/11.5 EER 8.2 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationProduct Data CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW DESIGN FEATURES
CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW Product Data CAPVP / CARVP A06001 A06002 CAPVU / CARVU The CAPVP, CARVP, CAPVU, and CARVU evaporator coils incorporate
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationRuud Achiever Series Heat Pump
Heat Pumps Ruud Achiever Series Heat Pump Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationRheem Classic Series Two Stage Heat Pump
Heat Pumps Rheem Classic Series Two Stage Heat Pump Efficiencies: 15-16 SEER/11.5-13 EER Nominal Sizes 2, 3, 4 and 5 Ton [7.03, 10.6, 14.06 and 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7
More informationLENNOX SLP98UHV DIAGNOSTIC CODES
Code Status of Equipment Action required to clear and recover - Idle mode (Decimal blinks at 1 Hertz -- 0.5 second ON, 0.5 second OFF) A Cubic feet per minute (cfm) setting for indoor blower (1 second
More informationProduct Data. CK5A, CK5B, CK5P Furnace N-Coils. Sizes A018 thru A060
Product Data CK5A, CK5B, CK5P Furnace N-Coils Sizes A018 thru A060 This vertical design N-coil is a furnace coil designed to provide the highest standards of reliability and durability. The coils are offered
More information4SCU13 PRODUCT SPECIFICATIONS
4SCU PRODUCT SPECIFICATIONS PHASE SPLIT SYSTEM AIR CONDITIONER FORM NO. 4SCULC-00 (0/07) coil ifice shipped with outdo unit f optimum efficiency and capacity Charged f 5 ft. of line set Trade available
More informationTWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3
TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3 The following tasks parallel the Jr. Tech (JT-1, 2, 3) description and development plan and use the Refrigeration and Air conditioning
More informationRPLA. Heat Pumps. Parts List 19-July-2011
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................
More informationRPNK. Heat Pumps. Parts List 25-July-2011
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................
More informationCASED HORIZONTAL FURNACE COIL. Model CK3B. Form No. SS-CK3B-01 FEATURES
SIZES AVAILABLE: The horizontal N-Coil is available in six coil sizes (024 through 060). It is designed to provide the highest standard of reliability and durability. CASING: The CK3B coil casing is unpainted
More informationThis parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps - Commercial Table of Contents Model Explanation...................................................................................................................
More informationRPKA. Heat Pumps. Parts List 07-May-2014
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................................................................
More informationSystem Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner
System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner Mohammad Khawaldeh Director, Unitary & Applied Product Units Presentation Outline Objectives Challenges Base
More information3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289
3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for
More informationDucted Reverse Cycle Air Conditioning of Distinction
Ducted Reverse Cycle Air Conditioning of Distinction Transforming global energy-efficiency into an art form! The Braemar advantage Braemar ducted reverse cycle air conditioners are brought to you by Seeley
More informationTECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1
Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a
More informationGlycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers
Glycol Systems Engineering Manual 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Stulz Air Technology Systems, Inc. Table of Contents Section - 1 Table
More informationThis parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................
More informationUniflair LE TDAR-TUAR
Uniflair LE TDAR-TUAR Direct Expansion air-cooled units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDAR) >
More informationAquavar SOLO 2 Frequently Asked Questions
Aquavar SOLO 2 Frequently Asked Questions How do I size the Aquavar SOLO 2 for the appropriate pump/motor combination? Can I use a 208 Volt motor? Can I run the Aquavar SOLO 2 up to 80HZ? What are the
More informationResearch of Variable Volume and Gas Injection DC Inverter Air Conditioning Compressor
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 Research of Variable Volume and Gas Inection DC Inverter Air Conditioning Compressor
More informationR E D I C O N T R O L S
R E D I C O N T R O L S Operation & Maintenance Manual Portable Service Purger for Low Pressure Chillers Model: PSP-LP-1B For Refrigerants R-11, R-113, R-114 & R-123 & Other Similar Refrigerants File Literature
More informationGlycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers
Glycol Systems Engineering Manual 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Stulz Table of Contents Section - 1 Table of Contents... 1-1 Glycol
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MODEL GS2000 / GS2001 OIL-LESS REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 R01099 GS2000.DOC NRP-OM-GS2000
More information450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES
450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES PART NO. 45053 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing
More informationGas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited
PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow models HEAT EXCHANGER Aluminized steel primary heat exchanger with crimped non-welded construction Stainless steel
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS C3, C4, C5 Uncased Indoor Coils (RepLcoil) 2 3/8" 1 3/8" 12 1/8" H 14 1/2" 19 1/2" 2 1/2" W "A" Coil Features Anteater Coil Technology: The Anteater TM coil is made with Uniguard
More information200 PSI FAST-FILL AIR SOURCE KIT
200 PSI FAST-FILL AIR SOURCE KIT 55% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20007 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of
More informationApplication Engineering Bulletin AE-1301 Issued June, Copeland APPLICATION GUIDELINES FOR ZP**K*E SCROLL COMPRESSORS FOR R-410A
4-1301 Application Engineering Bulletin AE-1301 Issued June, 1996 APPLICATION GUIDELINES FOR ZP**K*E SCROLL COMPRESSORS FOR R-410A Introduction The new model family of "ZP" compressors is designed for
More informationTechnology issues regarding Blends of Refrigerants Buffalo Research Laboratory
Technology issues regarding Blends of Refrigerants Buffalo Research Laboratory Agenda Basic Characteristics Background Degree of Superheat, degree of subcooling, average coil temperature Handling and setting
More informationFA4B FB4B FC4C DIRECT EXPANSION FAN COIL. Sizes 018 thru 070. Form No. PDS FA4B Air Handling Technology At Its Finest
DIRECT EXPANSION FAN COIL FA4B FB4B Sizes 018 thru 070 Air Handling Technology At Its Finest The FA4B, FB4B, and direct expansion fan coils are designed to cover a wide range of air handling requirements.
More informationMODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank
IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock or Electrocution: MODEL NUMBER: 20008 200 PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT: It is
More informationWorkhorse-15 Oxygen Generator
11436 Sorrento Valley Road, San Diego CA 92121 USA 858-558-0202 Fax 858-558-1915 Workhorse-15 Oxygen Generator Model No. 5719, 5727, 5735 for Domestic and International Units Part number 1432 Revision
More informationAIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.
2 GALLON AIR COMPRESSOR Model: 7517 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials
More informationDLE5.7CN V/60Hz 1~
dle57cn_102h3682_r290_115v_60hz_06-18_ds.xlsx Sales code: 102H3682 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 5,7cm³ / 0,35cu.in Oil quantity 221cm³ / 7,5fl.oz
More information97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO
97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and
More informationProduct Data. FB4CS, FB4CQ (50 Hz) Direct Expansion Fan Coil R- 410A Refrigerant Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST
, Q (50 Hz) Direct Expansion Fan Coil R- 410A Refrigerant izes 018 thru 060 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The 50 Hz fan coil has the proven technology of Carrier fan coil units with Puron
More informationSoft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II
Soft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II Stephen Li Daikin / Goodman Manufacturing Jan. 2016 1 2 Test objectives See the impact of R-32 on air
More informationProduct Data. FA4B FB4B FC4C Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest
Product Data FA4B FB4B Direct Expansion Fan Coil Sizes 018 thru 070 A02305 Air Handling Technology At Its Finest Carrier s FA4B, FB4B, and direct expansion multipoise fan coils are designed to cover a
More information200 PSI HIGH-FLOW AIR SOURCE KIT
200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of
More informationTechnical Instructions Document No. CA2N4721E-P25 Rev. 1, February, Modulating Control Valve for Hot Gas Control.
Document No. CAN7E-P MFB LX Series Modulating Control Valve Description Valves with magnetic actuator for modulating capacity control of refrigeration units and for heat recovery. Features Quick positioning
More informationOperation and Maintenance Manual
IMPORTANT NOTICE TO PURCHASER Check for damage immediately. Prior to shipment, all YELLOW JACKET RecoverXL/ XLT Refrigerant Recovery Systems are completely tested and inspected to assure compliance with
More informationVentam 85 Installation & Commissioning Instructions
Ventam Systems Ltd Unit D4 Seedbed Business Centre Vanguard Way Shoeburyness Essex SS3 9QY Phone 01702 382 307 Fax 01702 382 340 Ventam 85 Installation & Commissioning Instructions 1 General The Ventam
More informationDLE6.5CN V/60Hz 1~
dle65cn_102h3792_r290_115v_60hz_06-18_ds.xlsx Sales code: 102H3792 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 6,5cm³ / 0,4cu.in Oil quantity 221cm³ / 7,5fl.oz s
More informationPortable Oil Lube Air Compressors
Portable Oil Lube Air Compressors 8003631 8003632 0410149 8018968 8018940 Owner s Manual Read and understand operating instructions before use Safety definitions The information listed below should be
More informationRecoverXL and RecoverXLT Oil-Less Universal Refrigerant Recovery Systems Operation and Maintenance Manual
RecoverXL and RecoverXLT Oil-Less Universal Refrigerant Recovery Systems Operation and Maintenance Manual (English and Spanish. French and German available at www.yellowjacket.com) Table of Contents General
More information200 PSI COMPRESSORS - MODEL NUMBERS
200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read
More information100C Air Compressor Kit
10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is
More informationGas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Gas powered stop valves, type GPLX 80-150 REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical leaflet Gas powered stop valves, type GPLX 80-150 Contents Page Introduction........................................................................................3
More informationThis parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................
More informationIMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.
More informationModels EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations
Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization
More information400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO
400H HARDMOUNT AIR COMPRESSOR KIT PART NO. 40042 450H HARDMOUNT AIR COMPRESSOR KIT PART NO. 45042 400H 450H IMPORTANT: It is essential that you and any other operator of this product read and understand
More information420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO
420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this
More informationINSTALLATION GUIDE Gas Rangetops
INSTALLATION GUIDE Gas Rangetops Contents Wolf Gas Rangetops........................... 3 Safety Instructions............................ 4 Gas Rangetop Specifications.................... 5 Gas Rangetop
More informationThis parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................
More informationAE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions
AE19-1132 R8 December 2004 Reformatted November 2010 Copelametic Two-Stage Compressors Application and Service Instructions The Copeland two stage compressors have been developed to efficiently achieve
More informationNLE10CN V/50Hz 1~
nle10cn_105h6175_r290_2v_50hz_06-18_ds.xlsx Sales code: 105H6175 NLE10CN 2-240V/50Hz 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 10,09cm³ / 0,62cu.in Oil quantity
More informationASERCOM guidelines for the design of multiple compressor racks using frequency inverters
ASERCOM guidelines for the design of multiple compressor racks using frequency inverters Contents 1 SCOPE AND PURPOSE 2 SELECTION OF COMPRESSORS 3 DESIGN FEATURES 4 CONTROL FEATURES 5 STABILITY OF WORKING
More information450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES
EXTREME SERIES PART NO. 45043 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS
More informationMODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE
MODEL NUMBER: M20005 AIR SOURCE KIT 30% Duty Compressor on 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock
More informationCoils Designed to Fit Your Requirements. Temtrol Manufacturing OEM & Replacement Coils Since 1955
Temtrol Manufacturing OEM & Replacement Coils Since 1955 Coils Designed to Fit Your Requirements Chilled & Hot Water Direct Expansion Steam Distributing Condenser Standard Steam Quick Ship Program with
More informationPart 1 General Information Part 2 Outdoor Units... 8
Contents Part 1 General Information... 1 Part 2 Outdoor Units... 8 Part 3 Installation... 71 Part 4 Part 5 Trouble shooting 99 Control system. 126 Manufacture reserves the right to discontinue, or change
More informationUser s Information Manual
48HC with EnergyX R System Factory Installed Energy Recovery Single---Package Rooftop Unit (RTU) Gas Heating/Electric Cooling Units 15 to 25 Nominal Tons with Puronr (R---410A) Refrigerant User s Information
More informationSimple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18
The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability
More informationGuideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society
Guideline No.M-05(201510) M-05 AIR COMPRESSOR Issued date: 20 October 2015 China Classification Society Foreword This Guideline constitutes the CCS rules, and establishes the applicable technical requirements
More informationTradition & Technology
Gaterotor Support Gaterotor Single Screw Compressors Design & Operation Bearing Bearings Main Screw Parallex Slide System The VSM Single Screw Compressor has one main rotor and two gaterotors. All bearings
More information400C & 450C DUAL PERFORMANCE VALUE PACKS
(Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before
More informationVRF. Technical Data Book. DVM S ECO for Europe (R410A, 50Hz, HP) Model : AM***KXMDGH/EU
VRF Technical Data Book DVM S ECO for Europe (R410A, Hz, HP) Model : AM***KXMDGH/EU History Version Modification Date Remark 1 Newly Release the TDB 15.12.15 Nomenclature Outdoor Units Model Names AM 080
More informationWARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only
Natural Gas High Altitude Conversion Kit United States Installations Only Installation Instructions Light Commercial Packaged Gas Electric Units R7TQ Series 6, - 7 1/2, & 10 Ton (2,001 FT - 10,000 FT)
More information1020 Industrial Drive, Orlinda, TN fax
Operation Manual Tank Distribution System A-UPT Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.2 Warnings and Cautions... 1 1.2 Theory of Operation...
More information42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)
42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) 42047 Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 45052 Constant Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor
More informationDLE7.5CN V/50Hz 1~
dle75cn_102h4856_r290_2v_50hz_06-18_ds.xlsx Sales code: 102H4856 DLE7.5CN 2-240V/50Hz 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 7,48cm³ / 0,46cu.in Oil quantity
More informationModels EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations
Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization
More informationSPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.
2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or
More informationSmart JVA Module WARNING. For use with AquaLink RS systems with rev R firmware or newer.
INstallation and OPERATION Manual Smart JVA Module For use with AquaLink RS systems with rev R firmware or newer. H0370200 Rev C FOR YOUR SAFETY - This product must be installed and serviced by a contractor
More information