1 4SCU PRODUCT SPECIFICATIONS PHASE SPLIT SYSTEM AIR CONDITIONER FORM NO. 4SCULC-00 (0/07) coil ifice shipped with outdo unit f optimum efficiency and capacity Charged f 5 ft. of line set Trade available components High pressure cutout kit Crank case heater DESIGN Designed f ambients up to 5 F ACCESSORIES Low ambient control Thermal expansion valve kits Sht cycle protection kit WARRANTIES year parts; 5 year compress COMPRESSOR High-efficiency scroll compress R40A refrigerant Grommet-mounted compress f quiet operation Internally protected against high temperature mot overload conditions CABINET Full metal louvered panel coil guard protection Controls located in cner post f easy installation and service Rounded cners f safety and attractive, clean appearance Baked polyester paint finish over galvanized steel f maximum durability External gauge pts f easy service COIL Enhanced aluminum fins and copper tubing f high efficiency and capacity Raised coil prevents debris from collecting in bottom of coil and causing loss of airflow COMPONENTS Full metal louvered panels remove with just two screws per panel f easy coil cleaning and service Filter drier installed f system protection Service valves positioned f quick installation and easy service Page
2 PHASE SPLIT SYSTEM AC 4SCULC PHASE SPLIT SYSTEM AC 4SCULC MODEL NUMBER GUIDE 4 - R40A Split Condensing Unit - Nominal Louvered Commercial 4 SCU LC 6 T - A Min Revision Code Maj Revision Code VOLTAGE T x/60hz/Ph F - 460v/60hz/Ph Model COOLING PERFORMANCE WITH EVAPORATOR COILS Model Evapat Coil AHRI Capacity Sensible Capacity Btuh Piston Expansion Series NOMINAL CAPACITY 6-6,000 Btuh 48-48,000 Btuh 60-60,000 Btuh 4SCULC6F E(U,C,M)P50C ,800 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C ,800 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C ,800 6, /8 /8 7/8 /8 7/8 / A40 ELECTRICAL AND PHYSICAL DATA Model Voltage/ Phase/ Hz Voltage Range Min. Circuit Amp. Max. Over current Compress Load Locked Rot Load Fan Mot HP Nom. RPM Refrig. Charge (oz.) 4SCULC6T 08-0// / SCULC48T 08-0// / Weight (lbs.) 4SCULC6T 4SCULC48F E(U,C,M)P50C ,800 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6A,B,C ,800 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P4B,C ,800 6, /8 /8 7/8 /8 7/8 / A40 E(U,C)P60D ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,H)P49C ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,H)P6C ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,H)P6D ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P48C ,500 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C ,000 4, /8 /8 7/8 /8 7/8 / A40 4SCULC60T 08-0// / E(U,C)P60D ,000 4, /8 /8 7/8 /8 7/8 / A40 4SCULC6F 460// / SCULC48F 460// / SCULC60F 460// / SCULC48T E(U,C,H)P49C ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,H)P6C ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,H)P6D ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P48C ,500 4, /8 /8 7/8 /8 7/8 /8 NA A40 E(U,C,M)P50C ,000 4, /8 /8 7/8 /8 7/8 / A40 DIMENSIONS (IN.) AND SOUND RATINGS Model No. (T and F Models) A B C Sound Ratings dba 4SCULC6 4-/4 6-/4 9-/4 76 4SCULC48 9-/8 -/4 7-/4 78 4SCULC60F 4SCULC60T E(U,C,H)P49C ,000 4, /8 /8 7/8 /8 /8 / H40 E(U,C,H)P6C ,000 4, /8 /8 7/8 /8 /8 / H40 E(U,C,H)P6D ,000 4, /8 /8 7/8 /8 /8 / H40 E(U,C,H)P49C ,000 4, /8 /8 7/8 /8 /8 / H40 E(U,C,H)P6C ,000 4, /8 /8 7/8 /8 /8 / H40 E(U,C,H)P6D ,000 4, /8 /8 7/8 /8 /8 / H40 4SCULC60 9-/8 -/4 -/4 78 Page Page
3 PHASE SPLIT SYSTEM AC 4SCULC PHASE SPLIT SYSTEM AC 4SCULC Model Model Evapat Coil Air Handler Variable Speed ARI Capacity BTUH Sensible Expansion Piston Model Model Evapat Coil Air Handler ARI Capacity BTUH Sensible Expansion Piston E(U,C,M)P50C A95DFV090C0S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6A 80GUH070AV.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A95DFV090C0S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C 80GUH0CV ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A95DFV0C0S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C 80GUH0CV ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A95DFV0C0S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6A A80DFE045A.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95UHE090C6S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6B A80DFE090B ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A95UHE090C6S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A80DFE0C ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A95UHE0C0S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A80DFE0C ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A95UHE0C0S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6B A80DFV090B ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6B A95UHV045BS.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A80DFV0C ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6B A95UHV070BS.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A80DFV0C ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95UHV090CS ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6A A80UHE045A*.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A95UHV090CS.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6B A80UHE070B*.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95UHV090C6S ,00 6, /8 /8 7/8 /8 7/8 / A40 4SCULC6F E(U,C,M,H)P6B A80UHE090B6*.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A80UHE090C0* ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A80UHE090C0*.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A80UHE0C0* ,00 6, /8 /8 7/8 /8 7/8 / A40 4SCULC6F E(U,C,M,H)P6C A95UHV090C6S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95UHV090C0S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A95UHV090C0S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95UHV0C6S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A80UHE0C0*.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A95UHV0C6S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6A A80UHV070A.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95UHV0C0S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6B A80UHV090B.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A95UHV0C0S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A80UHV090C ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6B A96DFMV070B.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A80UHV090C ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A96DFMV090C ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A80UHV0C ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A96DFMV090C ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A80UHV0C ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A96DFMV090C ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6B A95DFE070B6S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A96DFMV090C ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95DFE090C6S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A96DFMV0C ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A95DFE090C6S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A96DFMV0C ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95DFE0C0S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6B A96UHMV070B.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A95DFE0C0S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A96UHMV090C ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6B A95DFV045BS.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 Page 4 Page 5
4 PHASE SPLIT SYSTEM AC 4SCULC PHASE SPLIT SYSTEM AC 4SCULC Model Expansion Model Expansion Model Evapat Coil Air Handler ARI Capacity BTUH Sensible Piston Model Evapat Coil Air Handler ARI Capacity BTUH Sensible Piston E(U,C,M,H)P6C A96UHMV090C.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A80UHV0C ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A96UHMV0C ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A80UHV0C ,000 6, /8 /8 /4 /8 7/8 / A40 4SCULC6F E(U,C,M,H)P6C A96UHMV0C ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6B EFVBC.5.5 5,00 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C EFV6CC ,400 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C LUF*****V ,400 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6B A95DFE070B6S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95DFE090C6S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A95DFE090C6S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95DFE0C0S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C LUF*****V ,00 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A95DFE0C0S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 ACBXCM ,000 5, /8 /8 7/8 /8 7/8 /8 NA NA E(U,C,M,H)P6B A95DFV045BS.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6A 80GUH070AV.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95DFV090C0S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C 80GUH0CV ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A95DFV090C0S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C 80GUH0CV ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95DFV0C0S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6A A80DFE045A.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A95DFV0C0S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6B A80DFE090B ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95UHE090C6S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A80DFE0C ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A80DFE0C ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6B A80DFV090B ,000 6, /8 /8 /4 /8 7/8 / A40 4SCULC6T E(U,C,M,H)P6C A95UHE090C6S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95UHE0C0S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A95UHE0C0S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A80DFV0C ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6B A95UHV045BS.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 4SCULC6T E(U,C,M,H)P6C A80DFV0C ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6A A80UHE045A*.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6B A80UHE070B*.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6B A95UHV070BS.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95UHV090CS ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A95UHV090CS.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6B A80UHE090B6*.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95UHV090C6S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A80UHE090C0* ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A95UHV090C6S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A80UHE090C0*.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95UHV090C0S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A80UHE0C0* ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A95UHV090C0S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A80UHE0C0*.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95UHV0C6S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6A A80UHV070A.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A95UHV0C6S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6B A80UHV090B.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A95UHV0C0S ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A80UHV090C ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A95UHV0C0S.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6C A80UHV090C ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M,H)P6B A96DFMV070B.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 Page 6 Page 7
5 PHASE SPLIT SYSTEM AC 4SCULC PHASE SPLIT SYSTEM AC 4SCULC Model Model Evapat Coil Air Handler ARI Capacity BTUH Sensible Expansion Piston Model Model Evapat Coil Air Handler ARI Capacity BTUH Sensible Expansion Piston E(U,C,M)P50C A96DFMV090C ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C 80GUH0CV ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A96DFMV090C ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A80DFE0C ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A96DFMV090C ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A80DFV0C ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A96DFMV090C ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C)P6D A80UHE5D0* ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A96DFMV0C ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A80UHV090C ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A96DFMV0C ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A80UHV0C ,000 4, /8 /8 7/8 /8 7/8 / A40 4SCULC6T E(U,C,M,H)P6B A96UHMV070B.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A96UHMV090C ,00 6, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A96UHMV090C.5.0 5,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A96UHMV0C ,00 6, /8 /8 7/8 /8 7/8 / A40 4SCULC48T E(U,C)P6D A80UHV5D ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A95DFE0C0S ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A95UHE0C0S ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C)P6D A95UHE5D0S ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C A96UHMV0C ,000 6, /8 /8 /4 /8 7/8 / A40 E(U,C)P6D A95UHV5D0S ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6B EFVBC.5.5 5,00 6, /8 /8 /4 /8 7/8 / A40 E(U,C,M)P50C A96UHMV0C ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C EFV6CC ,400 6, /8 /8 7/8 /8 7/8 / A40 E(U,C)P6D A96UHMV5D ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C LUF*****V ,400 6, /8 /8 7/8 /8 7/8 / A40 E(U,C)P6D EFV0DC ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M,H)P6C LUF*****V ,00 6, /8 /8 /4 /8 7/8 / A40 ACBXCM ,000 4, /8 /8 7/8 /8 7/8 /8 NA NA ACBXCM ,000 5, /8 /8 7/8 /8 7/8 /8 NA NA E(U,C,M)P50C 80GUH0CV ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A80DFE0C ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A80DFV0C ,000 4, /8 /8 7/8 /8 7/8 / A40 4SCULC60F ACBXCM ,000 4, /8 /8 7/8 /8 /8 /8 NA NA E(U,C)P6D A80UHE5D0* ,000 4, /8 /8 7/8 /8 7/8 / A40 4SCULC48F E(U,C,M)P50C A80UHV090C ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A80UHV0C ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C)P6D A80UHV5D ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A95DFE0C0S ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A95UHE0C0S ,000 4, /8 /8 7/8 /8 7/8 / A40 4SCULC60T ACBXCM ,000 4, /8 /8 7/8 /8 /8 /8 NA NA E(U,C)P6D A95UHE5D0S ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C)P6D A95UHV5D0S ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C,M)P50C A96UHMV0C ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C)P6D A96UHMV5D ,000 4, /8 /8 7/8 /8 7/8 / A40 E(U,C)P6D EFV0DC ,000 4, /8 /8 7/8 /8 7/8 / A40 ACBXCM ,000 4, /8 /8 7/8 /8 7/8 /8 NA NA Page 8 Page 9
6 PHASE SPLIT SYSTEM AC 4SCULC PHASE SPLIT SYSTEM AC 4SCULC COOLING PERFORMANCE EXTENDED RATINGS ACCESSORIES Model Model Temp DB/WB ºF Temp - DBºF Btuh S/T kw Btuh S/T kw Btuh S/T kw Btuh S/T kw Btuh S/T kw KIT NUMBER DESCRIPTION USED WITH 40K58 Blower Off Delay Kit All 4SCULC s 4SCULC6 E(U,C,M,H)P6A,B,C 85/7 9, , , , , /67 8, , , , , /6 7, , , , , J0 Compress Sound Covers All 4SCULC s 45F08 Compress Low Ambient Cut off All 4SCULC s 9G5 Freezestats (/8"tubing) All 4SCULC s 4SCULC48 E(U,C,M)P50C 85/7 54, , , , , /67 5, , , , , /6 50, , , , , A9 Freezestats (5/8 tubing) All 4SCULC s 47J7 Time off Control (A/C only) All 4SCULC s W6 Low Pressure Switch f loss of charge protection All 4SCULC s 4SCULC60 E(U,C,H)P49C 85/7 6, , , , , /67 60, , , , , /6 58, , , , , M7 Low Ambient All 4SCULC s A40 Kit 4SCULC6, 48, & 60 H40 Kit 4SCULC60 NOTE: M coils are in both painted and embossed metal cabinets - check the coil specification f specifics. NOTE: H coils are available in embossed metal only. Page 0 Page
7 PHASE SPLIT SYSTEM AC 4SCULC All specifications and illustrations subject to change without notice and without incurring obligations Fm No. 4SCULC-00 (0/07) 07 Allied Air Enterprises LLC, a Lennox International Inc. Company Printed in the U.S.A. Page
4SCU16LS PRODUCT SPECIFICATIONS 16 SEER SPLIT SYSTEM ENHANCED AIR CONDITIONING DESIGN COMPONENTS WARRANTY COMPRESSOR CABINET COILS
PRODUCT SPECIFICATIONS 16 S SPLIT SYSTEM ENHANCED AIR CONDITIONING FORM NO. -100 (06/2014) DESIGN Designed for ambients up to 125 F COMPONENTS Service valves positioned for quick installation and easy
More information4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP
4HP15 PRODUCT SPECIFICATIONS 15 SPLIT SYSTEM HEAT PUMP FORM NO. 4HP15-100 (12/2017) FEATURES AND BENEFITS R410A Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for
More informationAIR CONDITIONERS WA14**W SERIES
FORM NO. A66-225 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light
More informationAIR CONDITIONERS WA14 SERIES
FORM NO. A66-220 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.
FORM NO. AFJ-220 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*14C SERIES Efficiencies up to 16 S/13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7
More informationMAINLINE MLA14 AIR CONDITIONERS
FORM NO. AML-220 Supersedes Form No. PTZ-789 MAINLINE AIR CONDITIONERS Efficiencies up to 16 /13 Nominal Sizes 1.5-5 Ton [5.28 TO 17.6 KW] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured
More informationFMU4X, FMC4X FMU4P, FMC4P
ENVIRONMENTALLY SOUND REFRIGERANT FMU4X, FMC4X FMU4P, FMC4P Product Specifications HORIZONTAL FAN COILS FMU4P and FMC4P 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2 and 2 1/2 Tons ALL MODELS Horizontal
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.
FORM NO. AFJ-222 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*16C SERIES Efficiencies up to 16 SEER/13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to
More informationField Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.
Description: The High Efficiency Series air handlers are engineered to achieve or exceed today s demanding energy rating requirements. Specifically designed for horizontal mounting into a furred down ceiling.
More informationVARIABLE SPEED AIR CONDITIONERS
FORM NO. AFJ-224 Supersedes Form No. AFJ-222 VARIABLE SPEED AIR CONDITIONERS FO*20C SERIES Efficiencies up to 20 SEER/13 EER Nominal Sizes 2, 3, 4 & 5 Ton [7.03, 10.6, 14.06 & 17.6 kw] Cooling Capacities
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.
FORM NO. AFJ-221 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*13C SERIES Efficiencies 13-15.5 SEER/11.5-13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7
More informationProduct Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)
CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE Product Data (3619, 4823, 6025) A06009 A07904 The CAPMP and CARMP evaporator coils incorporate proven standards for reliable system operation and
More informationELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS
PRODUCT SPECIFICATIONS AIR CONDITIONERS EL16XC1 ELITE Series R-410A Bulletin 210758 November 2017 Supersedes August 2017 SEER up to 17.90 1.5 to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh MODEL NUMBER
More informationProduct Data CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW DESIGN FEATURES
CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW Product Data CAPVP / CARVP A06001 A06002 CAPVU / CARVU The CAPVP, CARVP, CAPVU, and CARVU evaporator coils incorporate
More informationEvaporator (DX) Freon Applications 1 12 Tons MHF
Evaporator (DX) Freon Applications 1 12 Tons > > Used For small to medium freon applications The Global Leader In Heat Exchange Technology With seven decades of experience and commitment to total client
More informationFSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities
TECHNICAL SPECIFICATIONS FSH1BG Series FEATURES and BENEFITS Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities 1 The iq Drive heat pump system features modulating compressor
More informationProduct Data. CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil --- Cased and Uncased Upflow, Downflow CAPVP / CARVP
CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil Cased and Uncased Upflow, Downflow Product Data CAPVP / CARVP A06001 A06002 CAPVU / CARVU The CAPVP, CARVP, CAPVU, and CARVU evaporator coils incorporate
More informationModel 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.
EVAPORATOR COILS A COIL UNCASED R 22 or R 410A SYSTEMS 1 5 Tons WEAU Certification applies only when the complete system is listed with ARI ISO 9001:2000 REGISTERED R 410A R 22 Size Shipping Weight Size
More informationUniflair LE TDAR-TUAR
Uniflair LE TDAR-TUAR Direct Expansion air-cooled units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDAR) >
More informationMODEL: SA13. Air Conditioners. Sure Comfort SA13. Air Conditioners
15.5 MODEL: SA13 Air Conditioners FORM NO. ASC-221 REV. 1 Sure Comfort SA13 Air Conditioners Efficiencies 13-15.5 S/11.5-13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5
More informationMAINLINE MLP14**A HEAT PUMPS
FORM NO. PML-806 REV. 2 Supersedes Form No. PTZ-789 MAINLINE HEAT PUMPS Efficiencies: 15 SEER/12.5 EER 9 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to
More informationSystem Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner
System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner Mohammad Khawaldeh Director, Unitary & Applied Product Units Presentation Outline Objectives Challenges Base
More informationThis parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................
More informationThis parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................
More informationCOMMERCIAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet
For Door Heights To 8 (environmental separation) COMMERCIAL LOW PROFILE 8 Data Sheet STANDARD CONSTRUCTION 8 1/2 high x 13 1/2 deep 1/5 hp two speed motor(s) Factory installed fan speed/heat switch White
More informationRuud Achiever Series Heat Pump
Heat Pumps Ruud Achiever Series Heat Pump RP14**F Series Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: up to 14 SEER/11.5 EER/8.2 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14 SEER/11.5 EER 8.2 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationRPLA. Heat Pumps. Parts List 19-July-2011
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................
More informationGlycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers
Glycol Systems Engineering Manual 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Stulz Air Technology Systems, Inc. Table of Contents Section - 1 Table
More informationDucted Reverse Cycle Air Conditioning of Distinction
Ducted Reverse Cycle Air Conditioning of Distinction Transforming global energy-efficiency into an art form! The Braemar advantage Braemar ducted reverse cycle air conditioners are brought to you by Seeley
More informationD A T A S H E E T. Technical Data. Maximum Working Gauge Pressure (bar) Capillary Tube Length (m) 1.5 (5Ft) Burst Gauge Pressure (bar) 234.
TRAE Stretch series of Thermal Expansion Valves are designed predominantly for AC, heat pumps, close control, industrial process cooling applications, and transportation AC with HP demand. The new TRAE
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationThis parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps - Commercial Table of Contents Model Explanation...................................................................................................................
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz.
SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz. Units ICE-O-Matic 11100 East 45th Ave Denver, Colorado 80239
More informationNordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units)
IMI CORNELIUS INC. www.cornelius.com Nordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units) Publication Number: 631806058 Revision Date: October 13, 2009 Revision: E Visit the
More informationGas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited
PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow models HEAT EXCHANGER Aluminized steel primary heat exchanger with crimped non-welded construction Stainless steel
More informationRPKA. Heat Pumps. Parts List 07-May-2014
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................................................................
More informationContents. Introduction Part 1 General Information Part 2 General Instruction Part 3 Outdoor Units Part 4 Installation...
MHVAC-DTSM-2012-07 Contents Contents Introduction... 1 Part 1 General Information... 2 Part 2 General Instruction... 13 Part 3 Outdoor Units... 17 Part 4 Installation... 316 Part 5 Control System... 356
More informationProduct Data. CK5A, CK5B, CK5P Furnace N-Coils. Sizes A018 thru A060
Product Data CK5A, CK5B, CK5P Furnace N-Coils Sizes A018 thru A060 This vertical design N-coil is a furnace coil designed to provide the highest standards of reliability and durability. The coils are offered
More informationRuud Achiever Series Heat Pump
Heat Pumps Ruud Achiever Series Heat Pump Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationGas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling
PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow models HEAT EXCHANGER Aluminized steel tapered design primary heat exchanger with crimped construction for long
More informationGlycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers
Glycol Systems Engineering Manual 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Stulz Table of Contents Section - 1 Table of Contents... 1-1 Glycol
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz.
SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz. Units Date 1/09 Table Of Contents This parts list contains
More informationRPNK. Heat Pumps. Parts List 25-July-2011
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................
More informationRheem Classic Series Two Stage Heat Pump
Heat Pumps Rheem Classic Series Two Stage Heat Pump Efficiencies: 15-16 SEER/11.5-13 EER Nominal Sizes 2, 3, 4 and 5 Ton [7.03, 10.6, 14.06 and 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7
More informationThis parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................
More informationModels EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations
Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization
More informationFA4B FB4B FC4C DIRECT EXPANSION FAN COIL. Sizes 018 thru 070. Form No. PDS FA4B Air Handling Technology At Its Finest
DIRECT EXPANSION FAN COIL FA4B FB4B Sizes 018 thru 070 Air Handling Technology At Its Finest The FA4B, FB4B, and direct expansion fan coils are designed to cover a wide range of air handling requirements.
More informationCASED HORIZONTAL FURNACE COIL. Model CK3B. Form No. SS-CK3B-01 FEATURES
SIZES AVAILABLE: The horizontal N-Coil is available in six coil sizes (024 through 060). It is designed to provide the highest standard of reliability and durability. CASING: The CK3B coil casing is unpainted
More informationTECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1
Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a
More informationProduct Data. FA4B FB4B FC4C Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest
Product Data FA4B FB4B Direct Expansion Fan Coil Sizes 018 thru 070 A02305 Air Handling Technology At Its Finest Carrier s FA4B, FB4B, and direct expansion multipoise fan coils are designed to cover a
More informationAll technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI
PACIFIC MX NITROX BREATHING AIR according to DIN EN 12021 MAX OXYGEN 40% DELIVERY l/min 600 m 3 h 36 PRESSURE BAR 225 PSI 3250 Quality system certified to iso 9001 BREATHING AIR is a product line that
More informationAIR COOLED SCREW WATER CHILLERS
GENERAL ELECTRIC AIR COOLED SCREW CHILLERS R-134a AASC Series AASC055B thru AASC445B 55 TR thru 445 TR 194 thru 1565 GE_AASC_Series.indd 1 3/26/12 5:20 PM GE_AASC_Series.indd 2 3/26/12 5:20 PM CONTENTS
More informationProduct Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest
Product Data FA4A FB4A Direct Expansion Fan Coil Sizes 018 thru 070 Air Handling Technology At Its Finest Carrier s FA4A, FB4A, and direct expansion multipoise fan coils are designed to cover a wide range
More informationPart 1 General Information Part 2 Outdoor Units... 8
Contents Part 1 General Information... 1 Part 2 Outdoor Units... 8 Part 3 Installation... 71 Part 4 Part 5 Trouble shooting 99 Control system. 126 Manufacture reserves the right to discontinue, or change
More informationSPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.
2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or
More informationAE R1 February 2015
February 2015 CoreSense Diagnostics for Copeland Scroll UltraTech Air Conditioning Compressors TABLE OF CONTENTS Safety Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to
More informationThe CWE / HWE-R Series: Overview. Frame and cabinet covering
Table Of Contents The CWE / HWE-R Series: Overview...... 1 Frame and cabinet covering... 1 Refrigerant gas...... 2 Compressors...... 2 Condensers...... 2 Fans... 3 Evaporator...... 3 Refrigerant circuit......
More informationModels EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations
Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization
More informationProduct Data. FB4CS, FB4CQ (50 Hz) Direct Expansion Fan Coil R- 410A Refrigerant Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST
, Q (50 Hz) Direct Expansion Fan Coil R- 410A Refrigerant izes 018 thru 060 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The 50 Hz fan coil has the proven technology of Carrier fan coil units with Puron
More informationType 3 - PSA Nitrogen Generation System
Type 3 - PSA Nitrogen Generation System Designed for: Dry or Pre-Action Fire Protection Systems (FPS) with a total capacity from 6,000 to 18,000 gallons 1.0 Nitrogen Generation Corrosion Inhibiting System
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS C3, C4, C5 Uncased Indoor Coils (RepLcoil) 2 3/8" 1 3/8" 12 1/8" H 14 1/2" 19 1/2" 2 1/2" W "A" Coil Features Anteater Coil Technology: The Anteater TM coil is made with Uniguard
More informationHazardous Duty Explosion Proof, Three Phase, Blue Chip Severe Duty
Applications: Hazardous Duty Explosion Proof, Three Phase Class I Groups C & D, Class II Groups F & G, Rigid Base installed in hazardous environments as defined by the motor's explosion proof class and
More informationCommercial Standard and High-Efficiency Condensing Units
F N. A11-176 V. 2 Supersedes Form No. A11-176 ev. 1 Commercial Standard and High-fficiency Condensing nits AW Standard fficiency AW High fficiency & N L [22.86 & 28 kw] AL F CNNS odel Number esignation...2
More informationECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)
ECS Protector PGEN-30 (PGEN-30E) Specifications For use under U.S. Patents 8,720,591, 9,144,700 and 9,186,533 Dimensions (cabinet): 24.5 (W) x 52.5 (H) x 8.5 (D) (622mm(W) x 1,334mm(H) x 216mm(D)) Dimensions
More informationGas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Gas powered stop valves, type GPLX 80-150 REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical leaflet Gas powered stop valves, type GPLX 80-150 Contents Page Introduction........................................................................................3
More informationNLE11CNL V/60Hz 1~
nle11cnl_105h5981_r290_115v_60hz_11-18_ds.xlsx Sales code: 105H5981 NLE11CNL 115-7V/60Hz 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 11,15cm³ / 0,68cu.in Oil quantity
More informationSoft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II
Soft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II Stephen Li Daikin / Goodman Manufacturing Jan. 2016 1 2 Test objectives See the impact of R-32 on air
More informationAquavar SOLO 2 Frequently Asked Questions
Aquavar SOLO 2 Frequently Asked Questions How do I size the Aquavar SOLO 2 for the appropriate pump/motor combination? Can I use a 208 Volt motor? Can I run the Aquavar SOLO 2 up to 80HZ? What are the
More information/ /
GN 4- kw/5.5-0 hp Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward GN: the dual output solution From cargo blanketing in LNG vessels to the inflation of Formula tires, nitrogen is used in
More informationNLE10CN V/50Hz 1~
nle10cn_105h6175_r290_2v_50hz_06-18_ds.xlsx Sales code: 105H6175 NLE10CN 2-240V/50Hz 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 10,09cm³ / 0,62cu.in Oil quantity
More informationDLE5.7CN V/60Hz 1~
dle57cn_102h3682_r290_115v_60hz_06-18_ds.xlsx Sales code: 102H3682 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 5,7cm³ / 0,35cu.in Oil quantity 221cm³ / 7,5fl.oz
More informationKKT Training Series: ECO Series, Preventative Maintenance
KKT Training Series: ECO Series, Preventative Maintenance p.m. process The preventative maintenance is a scheduled event with one hour of downtime. We must ensure the following procedure is performed:
More informationRefrigeration and Air Conditioning Technical leaflet
Refrigeration and Air Conditioning Technical leaflet Technical leaflet Injection valve type 2 Introduction Danfoss has developed a injection valve type 2 for desuperheating in 2-stage refrigeration systems
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MODEL GS2000 / GS2001 OIL-LESS REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 R01099 GS2000.DOC NRP-OM-GS2000
More informationDLE6.5CN V/60Hz 1~
dle65cn_102h3792_r290_115v_60hz_06-18_ds.xlsx Sales code: 102H3792 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 6,5cm³ / 0,4cu.in Oil quantity 221cm³ / 7,5fl.oz s
More informationCapacity regulator (hot gas bypass)
MAKING MODERN LIVING POSSIBLE Capacity regulator (hot gas bypass) TUH/TCHE/ Technical brochure Contents Page Introduction........................................................................................3
More informationTechnical Instructions Document No. CA2N4721E-P25 Rev. 1, February, Modulating Control Valve for Hot Gas Control.
Document No. CAN7E-P MFB LX Series Modulating Control Valve Description Valves with magnetic actuator for modulating capacity control of refrigeration units and for heat recovery. Features Quick positioning
More informationerc-o 2 -tech Ò innovative gas systems Markwerbener Str Weißenfels Germany
Compart Umwelttechnik GmbH erc-o 2 -tech Ò innovative gas systems Markwerbener Str. 24 06667 Weißenfels Germany Phone: 0049 (0) 3443/2901-0 Fax: 0049 (0) 3443/2901-12 Mail: compart-weissenfels@t-online.de
More informationTechnology issues regarding Blends of Refrigerants Buffalo Research Laboratory
Technology issues regarding Blends of Refrigerants Buffalo Research Laboratory Agenda Basic Characteristics Background Degree of Superheat, degree of subcooling, average coil temperature Handling and setting
More informationTON MODELS 50 HERTZ STYLE D
Millennium TM AIR COOLED SCREW LIQUID CHILLERS AIR COOLED SCREW HERMETIC INSTALLATION, OPERATION, MAINT. Supersedes: Nothing FORM 201.10-NM2 (696) 105-215 TON MODELS 50 HERTZ STYLE D #27960 With EPROM
More informationSystem Pressure Manager Standard & System Pressure Manager Plus
System Pressure Manager Standard & System Pressure Manager Plus Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,
More informationD. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER
. ACCESSORIES AAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANLES & LIFT CORS GALVANIC PROTECTION KITS MUSHROOM STRAINER SLUGE STRAINERS NEMA 4 WATERTIGHT CONTROL & UAL LEVEL CONTROL (Replaces
More informationDLE7.5CN V/50Hz 1~
dle75cn_102h4856_r290_2v_50hz_06-18_ds.xlsx Sales code: 102H4856 DLE7.5CN 2-240V/50Hz 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 7,48cm³ / 0,46cu.in Oil quantity
More informationthe new Ve- / VSE Range
the new Ve- / VSE Range Pure Power, perfect price 30-680 l/min 5 / 330 / 0 bar FULFILLS THE REQUIREMENT FOR LARGE QUANTITIES OF BREATHING AIR open or Super silent EASY OPERATION Breathing air acc. to DIN
More informationAE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions
AE19-1132 R8 December 2004 Reformatted November 2010 Copelametic Two-Stage Compressors Application and Service Instructions The Copeland two stage compressors have been developed to efficiently achieve
More informationAC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight
Technical Specifications Operating Instructions Maintenance Information Troubleshooting Guide Parts Diagrams AC1810 / AC1810-A THE EVOLUTION OF PERFECTION CAUTION: Before attempting to use or service this
More informationMODELS YLAA YLAA0175 DESIGN SERIES A, B & C DEVELOPMENT LEVEL A
AIR-COOLED SCROLL CHILLERS RENEWAL PARTS Supersedes: 50.72-RP (80) Form 50.72-RP () MODELS YLAA0070 - YLAA075 DESIGN SERIES A, B & C DEVELOPMENT LEVEL A GS5608 R-0A 70-75 TON 60 Hz Issue Date: January,
More informationHigh Performance Oilless Commercial Refrigerant Recovery Unit. User Manual Rev. 4 November 2010
High Performance Oilless Commercial Refrigerant Recovery Unit User Manual 2090-0217 Rev. 4 November 2010 Introduction Congratulations on your purchase of the STINGER high performance oilless recovery unit.
More informationKCS-Line. Air Cooled Condensers NEW CONTENTS PRODUCT DATA & INSTALLATION. Refrigerant: R404A, R507, R22
PRODUCT DATA & INSTALLATION Bulletin K50-KCS-PDI-1 1085695 For 50Hz see Bulletin K50-KCS-PDI-50 We are on the Internet www.keepriterefrigeration.com KCS-Line Air Cooled Condensers Refrigerant: R404A, R507,
More informationIMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.
More information200 PSI COMPRESSORS - MODEL NUMBERS
200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read
More informationCapacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Capacity regulator (hot gas bypass), type TUH/TCHE/ REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3
More informationMODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank
IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock or Electrocution: MODEL NUMBER: 20008 200 PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT: It is
More informationSupersedes: RP1(495) Form RP1 (1102)
RENEWAL PARTS CENTRIFUGAL LIQUID CHILLERS Supersedes: 0.9-RP(9) Form 0.9-RP (0) UNIT COMPONENTS MODEL YK (STYLES A & B) WITH MICROCOMPUTER CONTROL CENTER PART #3-000-00 FOR ELECTRO-MECHANICAL STARTER &
More informationThe X-11 Molding Chamber
The User Guide to The X-11 Molding Chamber Table of Contents Overview of Features & Specifications... 3 Features... 4-5 Safety & Maintenance... 6 Initial Startup Procedure... 7 Using the X-11... 8-9 Using
More informationFlow and check valves Logic valves series 551. Brochure
Flow and check valves Logic valves series 551 Brochure 2 Flow and check valves Logic valves series 551 3/2-directional valve, low pressure operated Qn = 2-120 l/min 3 3/2-directional valve, Qn = 120 l/min
More informationMODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE
MODEL NUMBER: M20005 AIR SOURCE KIT 30% Duty Compressor on 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock
More information