MagneticTurbo TM. TurboDrag pumps with pumping speed up to 1500 l/s TMH/U 1000 M / TMH/U 1600 M. Pumping speed. Start / Chapter content
|
|
- Jerome Powers
- 5 years ago
- Views:
Transcription
1 MagneticTurbo TM TurboDrag pumps with pumping speed up to 1500 l/s TMH/U 1000 M / TMH/U 1600 M Magnetic bearing system with 3 active and 2 passive axes, with the following benefits: maintenancefree, free of hydrocarbons, for installation in any orientation, low vibration and noise levels High gas throughput also in the case of low volume flow rates of the backing pump Versions for handling corrosive gases are available (C types) Integrated sealing gas system High critical backing pressure Fast and reliable venting through integrated and patented venting method Type of cooling: Air/water cooling Pumping speed pumping speed [l/s] N 2 Ar He CF 4 H pressure [mbar] TMH 1000 M, DN 200 pumping speed [l/s] N 2 Ar He CF4 H pressure [mbar] TMH 1600 M, DN
2 M8 201 Dimensions (in mm) Ø9 8xM8 12x ±0 7.5 Ø9 190± x Ø DN 200 ISO-K HV Ø x45 DN 200 ISO-F HV Ø250 2 DN 40 ISO-KF VV Ø250 TMH 1000 MP, DN 200 ISO-K TMH 1000 MPC, DN 200 ISO-F xM8 20 8xM ± ±0 Ø 9 Ø Ø DN 250 ISO-K HV Ø x45 DN 250 CF-F HV Ø Ø Ø 250 TMH 1600 MPCH, DN 250 ISO-K TMU 1600 MP, DN 250 CF-F 213
3 MagneticTurbo TM Technical data - TMH/U 1000 M / TMH/U 1600 M TMH/U 1000 MP DN 200 ISO-K/ ISO-F/CF-F TMH/U 1000 MPC DN 200 ISO-K/ ISO-F TMH/U 1000 MPCT DN 200 ISO-K/ ISO-F Connection nominal diameter Flange (in) DN 200 ISO-K DN 200 ISO-K DN 200 ISO-K Flange (out) DN 40 ISO-KF DN 40 ISO-KF DN 40 ISO-KF Venting connection at integrated venting valve G 1/8" G 1/8" G 1/8" Pumping speed [l/s] Hydrogen H Helium He Nitrogen N Argon Ar CF Compression ratio Hydrogen H 2 > > > Helium He > > > Nitrogen N 2 > > > Argon Ar > > > CF 4 - > > Max. fore vacuum pressure for N 2 [mbar] Max. gas throughput at 0.1 mbar HV [mbar l/s] Hydrogen H Helium He Nitrogen N Argon Ar CF Max. gas throughput at nom. rotation speed [mbar l/s] Pumping speed of used backing pump 65 m 3 /h 65 m 3 /h 65 m 3 /h Hydrogen H 2 >18 >18 >18 Helium He Nitrogen N Argon Ar CF Ultimate pressure (see page 144) [mbar] < < < Rotational speed [1/min] Run-up time [min] Cooling method, standard Water Water Water Cooling water consumption [l/h] Max. cooling water temperature [ C] Weight [kg] Ordering number pump ISO-K PM P PM P PM P ISO-F PM P PM P PM P CF-F PM P
4 TMH/U 1600 MP DN 250 ISO-K/ ISO-F/CF-F TMH/U 1600 MPCH DN 250 ISO-K/ ISO-F TMH/U 1600 MPCHT DN 250 ISO-K/ ISO-F DN 250 ISO-K DN 250 ISO-K DN 250 ISO-K DN 40 ISO-KF DN 40 ISO-KF DN 40 ISO-KF G 1/8" G 1/8" G 1/8" > > > > > > > > > > > > > > m 3 /h 65 m 3 /h 65 m 3 /h > < < < Water Water Water PM P PM P PM P PM P PM P PM P PM P
5 MagneticTurbo TM Ordering numbers power supplies and cables - TMH/U 1000 M / TMH/U 1600 M Ordering number pump TMH/U 1000 MP DN 200 ISO-K DN 200 ISO-F DN 200 CF-F PM P PM P PM P Ordering number pump TMH/U 1600 MP DN 250 ISO-K DN 250 ISO-F DN 250 CF PM P PM P PM P Magnetic drive electronic TCM 1601 magnetic drive electronic PM C PM C PM C Control units HPU 001 Handheld Programming Unit PM T PM T PM T Accessorie for HPU (Power supply, software, PC-cable) PM T PM T PM T Mains cable, length 3 m for TCM 1601 with safety plug (230 V AC) P ZA P ZA P ZA for TCM 1601 with UL plug (208 V AC) P ZF P ZF P ZF for TCM 1601 with UL plug (115 V AC) P ZE P ZE P ZE Connection cable, length 3 m for Turbo - TCM 1601 PM T PM T PM T 216
6 TMH 1000 MPC TMH 1000 MPCT DN 200 ISO-K DN 200 ISO-F DN 200 ISO-K DN 200 ISO-F PM P PM P PM P PM P TMH 1600 MPCH TMH 1600 MPCHT DN 250 ISO-K DN 250 ISO-F DN 250 ISO-K DN 250 ISO-F PM P PM P PM P PM P PM C PM C PM C PM C PM T PM T PM T PM T PM T PM T PM T PM T P ZA P ZA P ZA P ZA P ZF P ZF P ZF P ZF P ZE P ZE P ZE P ZE PM T PM T PM T PM T 217
7 MagneticTurbo TM Ordering numbers accessories - TMH/U 1000 M Ordering number pump TMH/U 1000 MP DN 200 ISO-K DN 200 ISO-F DN 200 CF-F PM P PM P PM P Cooling accessories Air cooling unit with safety plug (230/208 V) PM Z PM Z PM Z Air cooling unit with UL plug (115 V) PM Z PM Z PM Z Water cooling unit TZK V/50Hz PM Z PM Z PM Z Heating accessories Heating jacket 230 V AC, safety plug PM T PM T PM T Heating jacket 208 V AC, UL plug PM T PM T PM T Heating jacket 115 V AC, UL plug PM T PM T PM T ing pump control Pumping station control TCS 180 PM C PM C PM C Fore vacuum safety valve TVV 001, DN 16 ISO-KF 230 V AC PM Z PM Z PM Z Fore vacuum safety valve TVV 001, DN 16 ISO-KF 115 V AC PM Z PM Z PM Z General accessories Air drier TTV 001 PM Z PM Z PM Z Sealing gas valve PM Z PM Z PM Z Coated centering ring PM U PM U - Coated centering ring with protection screen PM U PM U - Protection screen - - PM Coated centering ring with integrated splinter shield PM U PM U Splinter shield - - PM Vibration damper PM X PM X PM X PWM-box, pre-switching unit for rotation speed control PM U PM U PM U Battery box TBB 001 PM K PM K PM K Serial Interface Converter RS PM T PM T PM T Profibus - Gateway TIC 250 PM T PM T PM T Mounting materials Coated centering ring, bracket screws PM T - - Coated centering ring with protect. screen, bracket screws PM T - - Coated centering ring with splinter shield, bracket screws PM T - - Coated centering ring, hexagonal bolts - PM T - Coated centering ring with protect. screen, hexagonal bolts - PM T - Coated centering ring with splinter shield, hexagonal bolts - PM T - Coated centering ring, stud screws - PM T - Coated centering ring with protection screen, stud screws - PM T - Coated centering ring with splinter shield, stud screws - PM T - Set of hexagonal bolts for CF-flanges - - PF T Set of stud screws for CF-flanges - - PF T 218
8 TMH 1000 MPC TMH 1000 MPCT DN 200 ISO-K DN 200 ISO-F DN 200 ISO-K DN 200 ISO-F PM P PM P PM P PM P PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM T PM T PM T PM T PM T PM T PM T PM T PM T PM T PM T PM T PM C PM C PM C PM C PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM U PM U PM U PM U PM U PM U PM U PM U PM U PM U PM U PM U PM X PM X PM X PM X PM U PM U PM U PM U PM K PM K PM K PM K PM T PM T PM T PM T PM T PM T PM T PM T PM T - PM T - PM T - PM T - PM T - PM T - - PM T - PM T - PM T - PM T - PM T - PM T - PM T - PM T - PM T - PM T - PM T - PM T 219
9 MagneticTurbo TM Ordering numbers accessories - TMH/U 1600 M Ordering number pump TMH/U 1600 MP DN 250 ISO-K DN 250 ISO-F DN 250 CF-F PM P PM P PM P Cooling accessories Air cooling unit with safety plug (230/208 V) PM Z PM Z PM Z Air cooling unit with UL plug (115 V) PM Z PM Z PM Z Water cooling unit TZK V/50Hz PM Z PM Z PM Z Heating accessories Heating jacket 230 V AC, safety plug PM T PM T PM T Heating jacket 208 V AC, UL plug PM T PM T PM T Heating jacket 115 V AC, UL plug PM T PM T PM T ing pump control Pumping station control TCS 180 PM C PM C PM C Fore vacuum safety valve TVV 001, DN 16 ISO-KF 230 V AC PM Z PM Z PM Z Fore vacuum safety valve TVV 001, DN 16 ISO-KF 115 V AC PM Z PM Z PM Z General accessories Air drier TTV 001 PM Z PM Z PM Z Sealing gas valve PM Z PM Z PM Z Coated centering ring PM U PM U - Coated centering ring with protection screen PM U PM U - Protection screen - - PM Coated centering ring with integrated splinter shield PM U PM U - Splinter shield - - PM Vibration damper PM X PM X PM X PWM-box, pre-switching unit for rotation speed control PM U PM U PM U Battery box TBB 001 PM K PM K PM K Serial Interface Converter RS PM T PM T PM T Profibus - Gateway TIC 250 PM T PM T PM T Mounting materials Coated centering ring, bracket screws PM T - - Coated centering ring with protect. screen, bracket screws PM T - - Coated centering ring with splinter shield, bracket screws PM T - - Coated centering ring, hexagonal bolts - PM T - Coated centering ring with protect. screen, hexagonal bolts - PM T - Coated centering ring with splinter shield, hexagonal bolts - PM T - Coated centering ring, stud screws - PM T - Coated centering ring with protection screen, stud screws - PM T - Coated centering ring with splinter shield, stud screws - PM T - Set of hexagonal bolts for CF-flanges - - PF T Set of stud screws for CF-flanges - - PF T 220
10 TMH 1600 MPCH TMH 1600 MPCHT DN 250 ISO-K DN 250 ISO-F DN 250 ISO-K DN 250 ISO-F PM P PM P PM P PM P PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM T PM T PM T PM T PM T PM T PM T PM T PM T PM T PM T PM T PM C PM C PM C PM C PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM Z PM U PM U PM U PM U PM U PM U PM U PM U PM U PM U PM U PM U PM X PM X PM X PM X PM U PM U PM U PM U PM K PM K PM K PM K PM T PM T PM T PM T PM T PM T PM T PM T PM T - PM T - PM T - PM T - PM T - PM T - - PM T - PM T - PM T - PM T - PM T - PM T - PM T - PM T - PM T - PM T - PM T - PM T 221
ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1
ATH 500 M Compact integrated drive Installation in any orientation Water or air cooled CE marked and ROHS compliant Heated version (MT) available for corrosive applicaitons. Pumping speed N 2 He H 2 Ar
More informationcooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated
ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics,
More informationVacuum Pumps. Turbomolecular Pumps F31 F32 F33 F34 F35 F36 F37 F38 F39 F40
F Turbomolecular Vacuum Pumps Vacuum Pumps CONTENTS Turbomolecular Pumps Page F31 F32 F33 Edwards. next Edwards. STP. 301. 603. 1003. A Series Edwards. STP. ix. ixa. ixr. L. XA Series F34 F35 F36 F37 Oerlikon
More informationHigh Va. High Vacuum Pumps. COOLVAC Cryo Pumps COOLPOWER Cold Heads COOLPAK Compressor Units
High Va High Vacuum Pumps COOLVAC Cryo Pumps COOLPOWER Cold Heads COOLPAK Compressor Units 2 Leybold Full Line Catalog 2018 - High Vacuum Pumps leybold Contents High Vacuum Pumps Turbomolecular Pumps TURBOVAC
More informationVacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation
Cryogenics Vacuum Dry Turbo Pumping Stations Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators Hermetically Sealed Pumps for He3 Recirculation Oils, Filters and Traps Valves, Fittings and Adaptors
More information2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version
2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version Type 6624 Impulse can be combined with... 10mm width orifice DN 0.8 to 1.2 with pressure range vacuum to 5bar medium separation, for
More informationSize : Ends : Min Temperature : Max Temperature : Materials : Galvanized steel flanges
Size : Ends : Min Temperature : Max Temperature : DN 32 to 600 Flanges ISO PN10/16-10 C + 100 C for EPDM and + 80 C for NBR Max Pressure : 16 Bars up to DN 300 Specifications : Absorb vibrations and noises
More informationbetter measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationPHOENIX L300i Best-in-class Helium Leak Detectors
180.85.02 Best-in-class Helium Leak Detectors The perfect Helium leak detector matching your demands The helium leak detector opens up new dimensions of productivity and reliability for your applications.
More informationCombined Pressure / Vacuum Relief Valve KITO VD/o
KITO VD/o DN D H kg* vacuum setting (mbar) pressure DIN ANSI DIN ANSI min max min max** 50 PN 16 2 220 332 351 11 3 50 10 75 80 PN 16 3 260 367 387 145 3 50 10 70 100 PN 16 4 260 368 393 178 3 50 10 80
More informationTwo-port valves, male threaded, PN25
4 379 Two-port valves, male threaded, PN25 VVG55... Two-port valves, externally threaded, PN25 Bronze Rg5 DN15... 25 mm (½"... 1") k vs 0.25... 6.3 m 3 /h Stroke 5.5 mm Suitable for type SQS35... or SQS65...
More informationHigh Va. High Vacuum Pumps
High Va High Vacuum Pumps TURBOVAC / TURBOVAC MAG Turbomolecular Pumps DIP / DIJ / OB / LEYBOJET Oil Diffusions Pumps COOLVAC Cryo Pumps COOLPOWER Cold Heads COOLPAK Compressor Units 240.00.02 Excerpt
More informationFig. 1: Mechanical vacuum gauge (left) and capacitive vacuum gauge (right)
Dear Readers! This is your 4pvd Newsletter. We hope you enjoy the information it contains. If you wish to unsubscribe, please send a blank Email to unsubscribe@4pvd.de June 1 st, 2006, Issue No. 24 Principles
More informationMass Flow Meter (MFM) for Gases
873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital
More informationExpert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
More informationX-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司
X-Flow Mass Flow Controller 2 Highlights Parker Hannifin Precision Fluidics Division is excited to introduce X-Flow, a new easy to use general purpose mass flow controller for your instrument, lab, or
More informationJUMO dtrans p30 Pressure Transmitter
609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability
More informationAGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY
AGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY Agilent Vacuum Products: Our Committment to Quality Agilent s commitment to quality and Measurement s philosophy Reference Standards (PNEUROP, ISO)
More informationThermal Energy Flowmeter Model KEC. Application Range. Special Features
Thermal Energy Flowmeter for gases measuring monitoring analysing KEC O O Direct mass flow rate measurement of gases OMeasuring O accuracy: ± 0.3% of full scale ±1.5% of reading on request: ± 0.3% of full
More informationMaterials : Electro galvanized steel flanges
Size : Ends : Min Temperature : Max Temperature : DN 32 to 600 Flanges PN10/16-10 C + 100 C for EPDM and + 80 C for NBR Max Pressure : 16 Bars up to DN 300 Specifications : Absorb vibrations and noises
More informationLiquid ring compressors
Liquid ring compressors KPH 85220, KPH 85227 Compression pressures: Suction volume flow: 2 to 7 bar 940 to 1450 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors
More informationDIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM
DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external
More informationOxford Instruments Austin, Inc.
User's User s Manual Issue 01 / March 2013 / OIAI Cryo-Plex 10 Oxford Instruments Austin, Inc. Issue 01 / March 2013 / Original Instructions Oxford Instruments Austin, Inc. is a wholly-owned subsidiary
More informationGUMMIKOMPENSATOR GKF8000 / GKF8130
GUMMIKOMPENSATOR GKF8000 / GKF8 Size : Ends : Min Temperature : Max Temperature : DN 32 to 600 Flanges PN10/16-10 C + 100 C for EPDM and + 80 C for NBR Max Pressure : 16 Bars up to DN 300 Specifications
More informationMaterials : Galvanized steel flanges
Size : Ends : Min Temperature : Max Temperature : DN 32 to 200 Flanges PN10/16-10 C + 80 C Max Pressure : 16 Bars Specifications : Absorb vibrations and noises Linear and angular compansion Single NBR
More informationCompact Ejectors. Compact Ejectors SCPi / SMPi Suction rate from 75 l/min to 185 l/min
Compact Ejectors Suitability for Industry-Specific Applications Applications Handling of air-tight as well as porous workpieces supply and vacuum monitoring in automated systems For use in sheet metal
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationLiquid ring vacuum pumps single-stage
Liquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 Pressure range: Suction volume flow: 150 to 1013 mbar 50 to 270 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum pumps are displacement
More informationThe affordable consumption counter for compressed air and gases R 3 /4 (DN 20)
VA 420 new The affordable consumption counter for compressed air and gases R 1 /4 (DN 8) DN 15 R 3 /4 (DN 20) DN 25 R 1 1 /4 (DN 32) DN 40 R 2 (DN 50) With mit und and ohne without Flansch flange Intelligent
More informationBROEN-LAB UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / VACUUM BROEN-LAB UNIFLEX TM FITTINGS FOR NON-BURNING 2.0 GASES / VACUUM PREMIUM LAB
BROEN-LAB UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / VACUUM LAB TABLE OF CONTENTS Content Page Table of Content 2 Product Overview 3 BROEN-LAB-LAB UniFlex TM 4-5 Fittings for Non-burnig 2.0 Gases/Vacuum
More informationGas Pressure Regulator HON 200
Product information serving the gas industry worldwide Applications, characteristics, technical data Application Gas supply to municipal, industrial and individual consumers Regulator for low-load rails
More informationCENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES
P0170E-1.DOCX/08.16/MG CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES With a Central Gas Supply System, individual work places or gas take-off stations are supplied with gas through
More informationVPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10
/ ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications
More informationDetermination of the Vacuum System for R2R by using a New Pumping Simulation Program
Determination of the Vacuum System for R2R by using a New Pumping Simulation Program AIMCAL WCHC Conference Memphis Oct 10 th, Peter Klingner, Dr. Stefan Lausberg, Dr. Marlis Sydow, Dr. Derek Corcoran
More information11. Spare Parts. applications since applications since
2 8 2 6 20 2 8 0 5 6 8 9 2 2 25 7 8 9 5 0 2 2 7 . Spare Parts * C0 C02 C06 C0 C7 C C0 C5 C58 Article No. Description B-26 B-2009 Steam generation Steam cylinder CY DN20 compl. with electrodes and hand
More informationLeak Detection. Catalog
Leak Detection Catalog Edition 2009 Contents General General Applications..................................................... 03 Products Modular System Leak Detectors for universal integration into industrial
More informationGasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01
Gasloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system G-GD 057 D01 Zero pressure regulator G-ND 057 D01 3.12 Technical description Multifunctional gas
More informationVolume Booster. Volume Booster Description Supply pressure Pressure range Connection Device Page max. bar bar thread
Volume ooster Supply pressure Pressure range onnection Device Page max. bar bar thread precise differential pressure also 17 0 1 / 10 and G 3 8 R50.02 differential pressure also 10 0.2 1 / 8 ¼ NPT 53.19
More informationDifferential pressure
Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor
More informationTBV-CM. Combined control & balancing valves for small terminal units For modulating control
TBV-CM Combined control & balancing valves for small terminal units For modulating control IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling systems, the
More informationSIHI LPH-X - Liquid Ring Compressors
- Liquid Ring Compressors LPH 50523 LPH 60527 Pressure range: Suction volume range: 0.2 to 1.5 bar 260 to 780 m³/h CONSTRUCTION Sterling SIHI liquid ring compressors are displacement compressors with a
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication
More informationARI-DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP
ARI-DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 ARI-DP32 / DP33 Pneumatic actuator Page 2 DP-Actuator Extended stem on air failure ARI-DP34 Pneumatic actuator Page 2 ARI-DP34T Pneumatic actuator Page 6
More informationGasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01
Gasloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating G-M(P) 055 D01 Two stage operating mode G-(LEP)Z 055 D01 3.0 Printed in Germany Edition 05.11 Nr.
More informationOld documentation - Only for your information! Product is not available any more!
Gasloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating G-M(P) 055 D01 Two stage operating mode G-(LEP)Z 055 D01 3.0 Printed in Germany Edition 05.11 Nr.
More informationVariable Temperature Storage Dewar Mount Inserts
Variable Temperature Storage Dewar Mount Inserts All inserts are available for either Liquid Helium or Liquid Nitrogen Dewars! DStat - External cryostat with insert leg DStatMag - Super Conducting Magnet
More informationThe Broadest Gauging Line in the Industry
The Broadest Gauging Line in the Industry Vacuum Measurement Varian s broad line of vacuum gauge controllers and gauge tubes are the most reliable, accurate, and economical means of measuring, monitoring,
More informationEXH. Specifications. Descriptions. Min. working pressure MPa
Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,
More informationMagnetic level switch type MR783 Instruction Manual
Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2
More informationPRESSURE REGULATOR LBM SERIES
VIRTUAL CATALOGUE FAIL TO OPEN REGULATOR HIGH FLOW COEFFICIENT WIDE PRESSURE-REGULATION RANGE FAST RESPONSE PRESSURE REGULATOR LBM SERIES FULL SEAL AT ZERO FLOW CAN BE SUPPLIED WITH MINIMUM / MAXIMUM PRESSURE
More informationMaterials : Dichromate zinc plated steel flanges
Size : Ends : Min Temperature : Max Temperature : DN 25 to 300 Flanges PN10/16-35 C + 130 C Max Pressure : 16 Bars up to DN150, 10 bars over Specifications : Absorb vibrations and noise Linear and angular
More informationPressure switches for air and water CS
Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the
More informationTrillium US Inc. Cryo-Plex 10 Cryogenic High Vacuum Pump User s Manual Rev A / November 2015
97-00032-000 Trillium US Inc. Cryo-Plex 10 Cryogenic High Vacuum Pump User s Manual Rev A / November 2015 For information about Trillium US Inc., visit the Trillium US Inc. Web site at: http://www.trilliumus.com
More informationElectronic Turbine Meter TERZ 94
Electronic Turbine Meter TERZ 9 PRODUT INFORMTION Reliable Measurements of Gas EETRONI TURINE METER TERZ 9 Methode of operation, construction 2 Methode of operation The TERZ 9 electronic turbine meter
More informationData sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119
Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,
More informationHigh Va. High Vacuum Pumps
High Va High Vacuum Pumps TURBOVAC / TURBOVAC MAG Turbomolecular Pumps DIP / OB Oil Diffusions Pumps COOLVAC Cryo Pumps COOLPOWER Cold Heads COOLPAK Compressor Units 240.00.02 Excerpt from the Leybold
More information2/2-Way Solenoid Control Valve
2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital
More informationLiquid ring compressor
Liquid ring compressor KLH 47005, KLH 47105 Compression pressures: Suction volume flow: 2 to 11 bar 56 to 65 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors of
More informationTA-H.U.B. Centralised balancing and control ENGINEERING ADVANTAGE
Prefab units TA-H.U.B. Centralised balancing and control Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE This customised balancing solution lets you balance
More informationWhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01
WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function Printed in Germany Edition 01 1 6 Technical Description Integrated gas-air system with high power
More informationMaterials : Dichromate zinc plated steel flanges or AISI 316
Size : Ends : Min Temperature : Max Temperature : DN 25 to 300 Flanges PN10/16-35 C + 90 C Max Pressure : 16 Bars (10 bars at 90 C) Specifications : Absorb vibrations and noise Linear and angular compansion
More informationAccessories for Sanitary Installations
5. Accessories for Sanitary Installations Flamco s Prescor B safety valves protect potable water systems from exceeding the maximum design operating pressure. Once the set pressure has been reached the
More informationAVP-F. p setting range (bar) Code No. 003H6200
Data sheet Differential pressure controller (PN 16) AVP - return and flow mounting, adjustable setting AVP-F - return mounting, fixed setting Description The controller has a control valve, an actuator
More informationSelf-operated Pressure Regulators Type 2405 Pressure Reducing Valve
Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve Application Pressure reducing valve for set points from 5 mbar to 10 bar Nominal size DN 15 to 50 Nominal pressure PN 16 to 40 Suitable
More informationCompact pressure switches for gas and air
Compact pressure es for gas and air / 5.0 Printed in Germany Edition 0.8 Nr. 9 544 6 Technical description The pressure is an adjustable compact pressure according to EN 854 for combustion plants. The
More informationFeatures. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)
1 X-Flow Mass Flow Controller Flow Range from 0.8 ml/min to 20 l/min Target Markets Laboratory and Process Instrumentation Pharma / Bio-Pharma Equipment Air Quality Monitoring Systems Furnace and Coatings
More informationSize 10 (D05) p max 320 bar (4600 PSI) Technical Features. Technical Data. Port dimensions ZB10A(B) SMT_0019 ZB K -
ase late with with ressure Relief Valve for Serial lates ssemblies Z0 Size 0 (D05) p max 320 bar (4600 SI) echnical Features ank cover mounted base manifold for hydraulic power packs which require one
More informationV5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet
V5001P Kombi-Auto Differential Pressure Control Valve Product specification sheet Content Application...1 Special Features...1 Valve Efficiency...1 Technical Data...2 Construction...2 Materials...2 Method
More informationWhirlWind Combined fully integrated gas/air control and safety system GB-WND 055 D01
WhirlWind Combined fully integrated gas/air control and safety system.04 Printed in Germany Edition 05.11 Nr. 40 508 1 6 Technical Description Integrated gas-air system with high power density based on
More informationATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE
ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in
More informationOXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:
OXY Integral INTERCON ENTERPRISES INC Tel: 800 665 6655 Fax: 604 946 5340 E-Mail: sales@intercononline.com Internet: www.intercononline.com Manual Integral 2006 1 INDEX 2-3 PREFACE 4 INTRODUCTION 5 Principle
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter
ABB MEASUREMENT & ANALYTICS DATA SHEET WaterMaster FEW530 Electromagnetic water meter 2 WATE RMASTE R F E W 530 ELECT ROMAGNE TIC WATE R ME TE R DS/FE W530/FE T3 -E N RE V. A Measurement made easy Cost
More informationExcerpt from the Oerlikon Leybold Vacuum Full Line Catalog 2015/2016 Catalog Part High Vacuum Pumps. High Vacuum Pumps
240.00.02 Excerpt from the Oerlikon Leybold Vacuum Full Line Catalog 2015/2016 Catalog Part High Vacuum Pumps High Vacuum Pumps Turbomolecular Pumps TURBOVAC Turbomolecular Pumps TURBOVAC MAG Oil Diffusion
More information2-Port Seat Valves with Flange, PN 16
4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in
More informationQUICK CONNECT FOR 2.0, 4.0 & 5.0 GASES
BROEN LAB QUICK CONNECT FOR 2.0, 4.0 & 5.0 ES BROEN LAB QUICK CONNECT FOR 2.0, 4.0 & 5.0 ES BROEN LAB QUICK CONNECT FOR 2.0, 4.0 & 5.0 ES LAB TABLE OF CONTENTS Content Page Table of Content 2 BROEN-LAB
More informationL21S/SR/ST Glass Level Gauges
L21S/SR/ST Glass Level Gauges Doc. no.: 150, en_cat_l21s/sr/st, 12/2014 Type of code Example: L21ST/1450/AANSI 3/4 150Lb RF/Large chamber Code 1 Basic type L21 2 Type of gauge S Tubular level gauge SR
More informationAnalogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM
Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM M+W Instruments Your partner Key Facts M+W Instruments was founded in 1988 and has always specialised in thermal mass flow meters
More informationMechanical Pressure Measurement
Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement
More informationMass Flow Controller (MFC)/ Mass Flow Meter (MFM) for gases
Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for gases Nominal flow ranges from l N /min up to l N /min High accuracy and repeatability Communication via standard signals or Industrial Ethernet Electromagnetic
More informationSelf-operated Regulators Accessories Differential Pressure and Flow Regulators
Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application
More informationCustomer Responsibilities
Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from ml N /min to 0 l N /min Applicable for aggressive gases Fieldbus option Type 870 can be combined with...
More informationHand lever valves VHER
Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:
More informationHELIX. On-Board IS Cryopump Installation Instructions
HELIX On-Board IS Cryopump Installation Instructions 2005 Helix Technology CorporationPart Number 8040596, Revision 12, 03/29/05 ECO Number 17066 Printed in USA HELIX TECHNOLOGY CORPORATION http://www.helixtechnology.com
More informationFlamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps
Airfix D-E 6442.eps GB Installation and operating instructions 1999, Exclusion of liability All operation and maintenance related technical information, data and instructions contained in these installation
More informationIDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger
More informationPTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationGAS PRESSURE CONTROL UNIT TYPE 132
GAS PRESSURE CONTROL UNIT TYPE 132 OUR DIVERSITY IS YOUR PROFIT. Gas Pressure Regulator Type 132 Scope of Application Scope of type 132 gas pressure regulator is to maintain the output pressure at a constant
More informationTorque Tube TB300 Digital Transmitters
Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional
More informationTA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control
TA-Modulator Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control IMI TA / Control valves / TA-Modulator TA-Modulator The
More informationbetter measurement Simply a question of
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.600 The powerful industrial professional for demanding applications involving air and gases. Industrial processes Pneumatic technology
More information14. Exploded View. Page 68
14. Exploded View Page 68 15. View of housing Page 69 11. Spare Parts HY05 HY13 55 E-2124010 Keys for safety, set=2pc. 54 E-2124012 Safety lock incl. 2 keys 1 B-3204031 1 B-2204101 1 B-2204111 1 2 B-2204105
More informationBULLETIN E485A. Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design.
BULLETIN E485A Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design www.rosseuropa.com 1 Glossary Response Time The smallest nominal value difference that causes a change
More informationTwo-port seat valves
4 345 Two-port seat valves with flange, PN16 VVF45... Two-port seat valves with flange, PN16 Spheroidal cast iron GGG-40 DN50...150 mm k vs 19...300 m 3 /h Stroke 20 or 40 mm Can be equipped with actuators
More informationRevision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline
Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline This training course outline is intended to cover the following: Introduction to vacuum Measurement Lubricated rotary pumps
More informationProcess Solutions. Electronic Turbine Meter TERZ 94 PROVEN TECHNOLOGY. SUPERIOR PERFORMANCE.
Process Solutions Electronic Turbine Meter TERZ 9 PROVEN TEHNOOGY. SUPERIOR PERFORMNE. Electronic Turbine Meter TERZ 9 Method of Operation The TERZ 9 electronic turbine meter is a flow meter which directly
More information