City & County of San Francisco Office of Contract Administration Purchasing. Bid #: ITSF /CD Req #: RQUH Attachment B

Size: px
Start display at page:

Download "City & County of San Francisco Office of Contract Administration Purchasing. Bid #: ITSF /CD Req #: RQUH Attachment B"

Transcription

1 I. General Requirements A. This bid is for a four-year (48 month) lease of portable gas detection instruments, including automated instrument maintenance and program monitoring supported by the successful bidder, for the following enterprises/divisions within the SFPUC: 1. Power Enterprise 2. Water Supply and Treatment Division - Distribution and Maintenance (WSTD-DM) 3. Water Supply and Treatment Division - System Operations (WSTD-SYSOPS) 4. City Distribution Division (CDD) B. The purpose of this program is to provide equipment and supplies necessary to assess whether hazardous gasses and adequate oxygen are present inside of confined spaces and other work areas where air quality hazards may be present. C. The instruments require routine frequent monitoring, calibration and maintenance to ensure they function accurately and reliably when deployed. The successful bidder must continuously, automatically and remotely monitor the instrument data and functionality, automatically replace instruments that are damaged or not fully functional and provide all other necessary repair and maintenance as needed. The successful bidder must also automatically and remotely detect declining sensor functionality, prior to sensor failure, and replace sensors when needed to ensure instruments are functional at all times. Calibration gas must be replenished automatically. All other consumable items (refer to Attachments C, D, E and F) to be supplied upon SFPUC's request. D. The successful bidder must automatically replace, at no additional charge, instruments needing maintenance with the same make and model of new or manufacturer's factoryrefurbished instruments within five (5) business days after maintenance needs are identified via the monitoring system. E. The successful bidder shall coordinate with SFPUC's portable instrument program administrators to ensure instruments are properly maintained, available, and ready for use. F. The successful bidder's instrument program monitoring system must generate notifications and reports based on instrument data downloads, which are to be customizable by SFPUC instrument program administrators, and to include, but not be limited to the following information: 1. Instrument utilization 2. Hazardous conditions detected 3. Calibration and bump testing history 4. Verification that calibration and bump testing occurs according SFPUC and manufacturer specifications 5. Calibration gas supply levels at all SFPUC sites (refer to Section V) Page 1 of 13

2 Req#: RQTJH G. Reports and notifications must be provided to SFPUC program administrators via both and successful bidder's web-hosted site automatically at the frequency determined by SFPUC, as well as on-demand as initiated by SFPUC. H. Successful bidder must have a minimum of five (5) years' experience providing, installing and operating gas detection instruments and associated support programs, and provide at least three (3) verifiable customer references (refer to Attachment H). I. Bids must be submitted on City and County of San Francisco bid documents. All attached forms must be completed and submitted with the bid package. An incomplete bid package may result in rejection of the bid. II. Technical Specifications A. Gas detection instruments must detect oxygen, carbon monoxide, hydrogen sulfide and explosive gasses. As noted in Section V. Approved Products, some of the instruments must also be able to detect organic vapor via photoionization detector (PID), as well as chlorine, ammonia, sulfur dioxide and carbon dioxide. B. All associated accessories, materials and supplies required for fully functional operation, calibration, maintenance and communications must be provided with the initial shipment of equipment to each site including, but not limited to: 1. remote sampling pumps 2. tubing 3. tubing connectors 4. probes 5. probe tubing 6. aspiration water barrier 7. carrying cases 8. calibration gasses 9. calibration gas regulators 10. docking station or other means of administering calibration gas to instruments and facilitating communication of data to service center 11. data cables 12. instrument battery chargers C. The bid price must include the cost for the initial supply of all instruments, accessories, materials and supplies required for fully functional operation, calibration, maintenance and communications, as well as training, initial delivery, assembly/set-up and testing for full functionality. D. The successful bidder must monitor calibration gas supply levels, and automatically replenish calibration gas as required to ensure calibration and bump testing capabilities are maintained at all times. Calibration gas price information is to be listed in Attachments C, D, E and F. Page 2 of 13

3 E. With the exception of calibration gas, all consumable items, including but not limited to tubing, tubing connectors, aspiration water barriers, probes and probe tubing, will be ordered separately as needed by each enterprise/division. Consumables prices are to be listed in Attachments C, D, E and F. F. Instrument program monitoring system must be compatible with both dynamic host configuration protocol (DHCP) and fixed internet protocol (fixed IP). G. SFPUC will furnish viable internet connection ports, or equivalent means of communication with the successful bidder's service center. H. Automated instrument maintenance and program monitoring system must include, but not be limited to: 1. web-hosted interface 2. remote instrument configuration 3. inventory evaluation 4. report and notification management and generation 5. remote instrument software upgrades 6. asset tracking by serial number 7. secure off-site storage of gas hazard and instrumentation data I. Successful bidder must provide live technical support via and telephone from at least 5:00 a.m. to 5:00 p.m. Pacific Time Monday through Thursday, and 5:00 a.m. to 3:00 p.m. Pacific Time on Friday. III. Delivery A. Initial equipment and supplies required for full functionality are to be delivered to each individual site, as listed in Section V. B. With the exception of the initial equipment and supplies deliveries (refer to Section III.A. above), replacement equipment and consumables listed in Attachments C, D, E and F shall be delivered to the primary enterprise/division address for which the replacement equipment or consumables are intended, as follows: 1. SFPUC-Power Enterprise, 651 Bryant Street, San Francisco, California 94107; Attention: WAREHOUSE 2. SFPUC-Water Supply and Treatment Division - Distribution and Maintenance (WSTD-DM), 1000 El Camino Real, Millbrae, California 94030; Attention: WAREHOUSE Page 3 of 13

4 3. SFPUC-Water Supply and Treatment Division - System Operations (WSTD- SYSOPS), 1000 El Camino Real, Millbrae, California 94030; Attention: WAREHOUSE 4. SFPUC-City Distribution Division (CDD), 1990 Newcomb Avenue, San Francisco, California 94124; Attention: WAREHOUSE C. The complete name of the specific site(s) for which replacement equipment or consumables are intended must be clearly indicated in the packing materials. IV. Installation/Setup A. Successful bidder, if not the manufacturer, must be a manufacturer-certified representative, and must provide complete onsite installation/setup and testing of all equipment, including calibration and communication systems, and ensure full functionality. B. Bidders must indicate site requirements needed for full functionality such as space, electricity and data connectivity in Attachment G for each site. V. Approved Products (by enterprise/division and site) Successful bidder must provide the following equipment and supplies manufactured and/or supplied by Industrial Scientific Corporation, or approved equal, at the following sites: In the event of discrepancies between part numbers (P/N) of the items specified herein and current P/N, bidder declares, by submitting a bid, that bidder is providing the correct and most current P/N corresponding to the technical specifications and descriptions of the items specified. POWER ENTERPRISE - one (1) site Corporation Yard, 651 Bryant Street, San Francisco, California P/N VTS-K ; Ventis MX4 Multi-Gas Monitor (standard 4 gasses), orange; Quantity: 3 2. P/N VTS-K llll; Ventis MX4 Multi-Gas Monitor (standard 4 gasses); Quantity: 3 3. P/N ; DSXi Docking Station for Ventis MX4; Quantity: 2 4. P/N ; DS2 gas cylinder regulator with pressure switch for 58/103 liter cylinders; 5. P/N ; Calibration gas consisting of 100 ppm carbon monoxide, 25 ppm hydrogen sulfide, 25 percent pentane lower explosive limit, 18 percent oxygen and the remainder (approximately 57 percent) nitrogen; 6. P/N ; Calibration gas cylinder holder; 7. P/N ; Five-port calibration manifold; Page 4 of 13

5 8. P/N ; Tubing, urethane; one hundred (100) feet length, one eighth (1/8) inch interior diameter (ID); 9. P/N ; Tubing connector, female, three sixteenths (3/16) inch interior diameter (ID); P/N ; Tubing connector, male, three sixteenths (3/16) inch interior diameter (ID); P/N ; Aspiration water barrier; P/N ; Extendable probe, extendable to 6 feet; 13. P/N ; Extendable probe tubing kit; 14. P/N ; Six-unit charger for Ventis MX4; WATER SUPPLY AND TREATMENT DIVISION - DISTRIBUTION AND MAINTENANCE (WSTD-DM) - two (2) sites A. Millbrae Corporation Yard, 1000 El Camino Real, Millbrae, California P/N VTS-K ; Ventis MX4 Multi-Gas Monitor (standard 4 gasses), black; Quantity: 4 2. P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus ammonia), 3. P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus chlorine), 4. P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus sulfur dioxide), 5. P/N ; DSXi Docking Station for Ventis MX4; 6. P/N ; DSXi Docking Station for Ventis MX6; 7. P/N ; DS2 gas cylinder regulator with pressure switch for 58/103 liter cylinders; Quantity: 5 8. P/N ; Calibration gas consisting of 100 ppm carbon monoxide, 25 percent pentane nitrogen; 9. P/N ; Calibration gas consisting of 25 ppm hydrogen sulfide; 10. P/N ; Calibration gas consisting of 10 ppm chlorine; 11. P/N ; Calibration gas consisting of 10 ppm sulfur dioxide; 12. P/N ; Calibration gas consisting of 25 ppm ammonia; 13. P/N ; Calibration gas cylinder holder; Quantity: P/N ; Five-port calibration manifold; Quantity: P/N ; Tubing, PTFE (Teflon) lined urethane; one hundred (100) feet length, one eighth (1/8) inch interior diameter (ID); Page 5 of 13

6 16. P/N ; Tubing connector, female, one eighth (1/8) inch interior diameter (ID); P/N ; Tubing connector, male, one eighth (1/8) inch interior diameter (ID); P/N ; Aspiration water barrier; P/N ; Extendable probe, extendable to 6 feet; 21. P/N ; Extendable probe tubing kit; B. Sunol Corporation Yard; 505 Paloma Way, Sunol, California P/N VTS-K ; Ventis MX4 Multi-Gas Monitor (standard 4 gasses), black; Quantity: 4 2. P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus ammonia), 3. P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus chlorine), 4. P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus sulfur dioxide), 5. P/N ; DSXi Docking Station for Ventis MX4; 6. P/N ; DSXi Docking Station for Ventis MX6; 7. P/N ; DS2 gas cylinder regulator with pressure switch for 58/103 liter cylinders; Quantity: 5 8. P/N ; Calibration gas consisting of 100 ppm carbon monoxide, 25 percent pentane nitrogen; 9. P/N ; Calibration gas consisting of 25 ppm hydrogen sulfide; 10. P/N ; Calibration gas consisting of 10 ppm chlorine; 11. P/N ; Calibration gas consisting of 10 ppm sulfur dioxide; 12. P/N ; Calibration gas consisting of 25 ppm ammonia; 13. P/N ; Calibration gas cylinder holder; Quantity: P/N ; Five-port calibration manifold; Quantity: P/N ; Tubing, PTFE (Teflon) lined urethane; one hundred (100) feet length, one eighth (1/8) inch interior diameter (ID); 16. P/N ; Tubing connector, female, one eighth (1/8) inch interior diameter (ID); P/N ; Tubing connector, male, one eighth (1/8) inch interior diameter (ID); P/N ; Aspiration water barrier; 5 Page 6 of 13

7 Bid#:ITSF /CD 20. P/N ; Extendable probe, extendable to 6 feet; 21. P/N ; Extendable probe tubing kit; WATER SUPPLY AND TREATMENT DIVISION - SYSTEM OPERATIONS (WSTD-SYSOPS) - five (5) sites A. Harry Tracy Water Treatment Plant, 2901 Crystal Springs Rd, San Bruno, California P/N VTS-K ; Ventis MX4 Multi-Gas Monitor (standard 4 gasses), black; Quantity: 4 2. P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus ammonia), 3. P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus chlorine), 4. P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus sulfur dioxide), 5. P/N ; DSXi Docking Station for Ventis MX4; 6. P/N ; DSXi Docking Station for Ventis MX6; 7. P/N ; DS2 gas cylinder regulator with pressure switch for 58/103 liter cylinders; Quantity: 5 8. P/N ; Calibration gas consisting of 100 ppm carbon monoxide, 25 percent pentane nitrogen; 9. P/N ; Calibration gas consisting of 25 ppm hydrogen sulfide; 10. P/N ; Calibration gas consisting of 10 ppm chlorine; 11. P/N ; Calibration gas consisting of 10 ppm sulfur dioxide; 12. P/N ; Calibration gas consisting of 25 ppm ammonia; 13. P/N ; Calibration gas cylinder holder; Quantity: P/N ; Five-port calibration manifold; Quantity: P/N ; Tubing, PTFE (Teflon) lined urethane; one hundred (100) feet length, one eighth (1/8) inch interior diameter (ID); 16. P/N ; Tubing connector, female, one eighth (1/8) inch interior diameter (ID); P/N ; Tubing connector, male, one eighth (1/8) inch interior diameter (ID); P/N ; Aspiration water barrier; P/N ; Extendable probe, extendable to 6 feet; 21. P/N ; Extendable probe tubing kit; Page 7 of 13

8 B. Pulgas Dechlorination Facility, 66 Canada Rd, Redwood City, California P/N MX6-K123Q211; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus carbon dioxide), 2. P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus chlorine), 3. P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus sulfur dioxide), 4. P/N ; DSXi Docking Station for Ventis MX6; 5. P/N ; DS2 gas cylinder regulator with pressure switch for 58/103 liter cylinders; Quantity: 5 6. P/N ; Calibration gas consisting of 100 ppm carbon monoxide, 25 percent pentane nitrogen; 7. P/N ; Calibration gas consisting of 25 ppm hydrogen sulfide; 8. P/N ; calibration gas consisting of 10 ppm chlorine; 9. P/N ; Calibration gas consisting of 10 ppm sulfur dioxide;; 10. P/N ; Calibration gas consisting of 25 ppm carbon dioxide; 11. P/N ; Calibration gas cylinder holder; Quantity: P/N ; igas Reader; 13. P/N ; Tubing, PTFE (Teflon) lined urethane; one hundred (100) feet length, one eighth (1/8) inch interior diameter (ID); 14. P/N ; Tubing connector, female, one eighth (1/8) inch interior diameter (ID); P/N ; Tubing connector, male, one eighth (1/8) inch interior diameter (ID); P/N ; Aspiration water barrier; P/N ; Extendable probe, extendable to 6 feet; 19. P/N ; Extendable probe tubing kit; C. Sunol Valley Water Treatment Plant, 8653 Calaveras Road, Sunol, California P/N VTS-K ; Ventis MX4 Multi-Gas Monitor (standard 4 gasses), black; Quantity: 4 2. P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus ammonia), 3. P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus chlorine), Page 8 of 13

9 4. P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus sulfur dioxide), 5. P/N ; DSXi Docking Station for Ventis MX4; 6. P/N ; DSXi Docking Station for Ventis MX6; 7. P/N ; DS2 gas cylinder regulator with pressure switch for 58/103 liter cylinders; Quantity: 5 8. P/N ; Calibration gas consisting of 100 ppm carbon monoxide, 25 percent pentane nitrogen; 9. P/N ; Calibration gas consisting of 25 ppm hydrogen sulfide; 10. P/N ; Calibration gas consisting of 10 ppm chlorine; 11. P/N ; Calibration gas consisting of 10 ppm sulfur dioxide; 12. P/N ; Calibration gas consisting of 25 ppm ammonia; 13. P/N ; Five-port calibration manifold; Quantity: P/N ; Calibration gas cylinder holder; Quantity: P/N ; Tubing, PTFE (Teflon) lined urethane; one hundred (100) feet length, one eighth (1/8) inch interior diameter (ID); 16. P/N ; Tubing connector, female, one eighth (1/8) inch interior diameter (ID); P/N ; Tubing connector, male, one eighth (1/8) inch interior diameter (ID); P/N ; Aspiration water barrier; P/N ; Extendable probe, extendable to 6 feet; 21. P/N ; Extendable probe tubing kit; D. San Antonio Pumping Station Chemical Facility, 555 Calaveras Road, Sunol, CA P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus ammonia), 2. P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus chlorine), 3. P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus sulfur dioxide), 4. P/N ; DSXi Docking Station for Ventis MX6; 5. P/N ; DS2 gas cylinder regulator with pressure switch for 58/103 liter cylinders; Quantity: 5 Page 9 of 13

10 6. P/N ; Calibration gas consisting of 100 ppm carbon monoxide, 25 percent pentane nitrogen; 7. P/N ; Calibration gas consisting of 25 ppm hydrogen sulfide; 8. P/N ; Calibration gas consisting of 10 ppm chlorine; 9. P/N ; Calibration gas consisting of 10 ppm sulfur dioxide; 10. P/N ; Calibration gas consisting of 25 ppm ammonia; 11. P/N ; calibration gas cylinder holder; Quantity: P/N ; Tubing, PTFE (Teflon) lined urethane; one hundred (100) feet length, one eighth (1/8) inch interior diameter (ID); 13. P/N ; Tubing connector, female, one eighth (1/8) inch interior diameter (ID); P/N ; Tubing connector, male, one eighth (1/8) inch interior diameter (ID); P/N ; Aspiration water barrier; P/N ; Extendable probe, extendable to 6 feet; 18. P/N ; Extendable probe tubing kit; E. Tesla Portal, 9000 West Vernalis Road, Tracy, California P/N MX6-K ; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus chlorine), 2. P/N ; DSXi Docking Station for Ventis MX6; 3. P/N ; DS2 gas cylinder regulator with pressure switch for 58/103 liter cylinders; Quantity: 2 4. P/N ; Calibration gas consisting of 100 ppm carbon monoxide, 25 ppm hydrogen sulfide, 25 percent pentane lower explosive limit, 18 percent oxygen and the remainder (approximately 57 percent) nitrogen; 5. P/N ; Calibration gas consisting of 10 ppm chlorine; 6. P/N ; Calibration gas cylinder holder; Quantity: 2 7. P/N ; Tubing, PTFE (Teflon) lined urethane; one hundred (100) feet length, one eighth (1/8) inch interior diameter (ID); 8. P/N ; Tubing connector, female, one eighth (1/8) inch interior diameter (ID); 2 9. P/N ; Tubing connector, male, one eighth (1/8) inch interior diameter (ID); P/N ; Aspiration water barrier; Quantity: P/N ; Extendable probe, extendable to 6 feet; 13. P/N ; Extendable probe tubing kit; Page 10 of 13

11 Bid#: ITSF /CD CITY DISTRIBUTION DIVISION (CDD) - two (2) sites A. Corporation Yard, 1990 Newcomb Avenue, San Francisco, California P/N VTS-K ; Ventis MX4 Multi-Gas Monitor (standard 4 gasses), orange; Quantity: 3 2. P/N VTS-K ; Ventis MX4 Multi-Gas Monitor (standard 4 gasses); 3. P/N MX6-KJ73R211; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus chlorine and photionization detector), 4. P/N ; DSXi Docking Station for Ventis MX4; 5. P/N ; DSXi Docking Station for Ventis MX6; 6. P/N ; DS2 gas cylinder regulator with pressure switch for 58/103 liter cylinders; Quantity: 4 7. P/N ; Calibration gas consisting of 100 ppm carbon monoxide, 25 percent pentane nitrogen; 8. P/N ; Calibration gas consisting of 25 ppm hydrogen sulfide; 9. P/N ; Calibration gas consisting of 10 ppm chlorine; 10. P/N ; Calibration gas consisting of 100 ppm isobutylene; 11. P/N ; Calibration gas cylinder holder; Quantity: P/N ; Five-port calibration manifold; Quantity: P/N ; Tubing, PTFE (Teflon) lined urethane; one hundred (100) feet length, one eighth (1/8) inch interior diameter (LD); 14. P/N ; Tubing connector, female, one eighth (1/8) inch interior diameter (ID); P/N ; Tubing connector, male, one eighth (1/8) inch interior diameter (ID); P/N ; Aspiration water barrier; Quantity: P/N ; Extendable probe, extendable to 6 feet; 19. P/N ; Extendable probe tubing kit; 20. P/N ; Six-unit charger for Ventis MX4; B. Lake Merced Pump Station, 991 Lake Merced Boulevard, San Francisco, California P/N VTS-K ; Ventis MX4 Multi-Gas Monitor (standard 4 gasses), orange; Quantity: 3 2. P/N VTS-K ; Ventis MX4 Multi-Gas Monitor (standard 4 gasses); 3. P/N MX6-KJ73R211; MX6 ibrid Multi-Gas Monitor (standard 4 gasses, plus chlorine and photionization detector), 4. P/N ; DSXi Docking Station for Ventis MX4; Page 11 of 13

12 5. P/N ; DSXi Docking Station for Ventis MX6; 6. P/N ; DS2 gas cylinder regulator with pressure switch for 58/103 liter cylinders; Quantity: 4 7. P/N ; Calibration gas consisting of 100 ppm carbon monoxide, 25 percent pentane nitrogen; 8. P/N ; Calibration gas consisting of 25 ppm hydrogen sulfide; 9. P/N ; Calibration gas consisting of 10 ppm chlorine; 10. P/N ; Calibration gas consisting of 100 ppm isobutylene; 11. P/N ; Calibration gas cylinder holder; Quantity: P/N ; Five-port calibration manifold; Quantity: P/N ; Tubing, PTFE (Teflon) lined urethane; one hundred (100) feet length, one eighth (1/8) inch interior diameter (ID); 14. P/N ; Tubing connector, female, one eighth (1/8) inch interior diameter (ID); P/N ; Tubing connector, male, one eighth (1/8) inch interior diameter (ID); P/N ; Aspiration water barrier; Quantity: P/N ; Extendable probe, extendable to 6 feet; 19. P/N ; Extendable probe tubing kit; 20. P/N ; Six-unit charger for Ventis MX4; VI. Submittals Bidders shall complete and submit all City and County of San Francisco bid documentation. VII. Training A. The manufacturer or manufacturer-certified representative must provide training for designated SFPUC employees at each site listed in Section V. B. The manufacturer/manufacturer-certified representative must provide a minimum of one (1) in-person, on-site training session per site, to include up to twenty (20) people per session. C. Training must consist of the complete overview of instrument operation and maintenance including, but not limited to, sampling techniques, interpreting readings, adjusting settings, performing calibration and maintenance, instrument and instrument parts and supplies replacement procedures, technical support, etc. D. Training must be a minimum of one (1) hour per site. Page 12 of 13

13 Req #: RQTJH VIII. Authorized Maintenance/Service Facility Maintenance and service must be provided directly by the manufacturer, or by a manufacturer-certified service center. IX. Lease Agreement See Attachment I for draft lease agreement. A fully executed agreement will be required prior to award. X. Insurance See draft lease agreement (Attachment I) for insurance requirements. XI. Pricing A. All prices must be placed on the bid sheets. Prices listed elsewhere will not be considered. B. Prices to be inclusive of all costs to the City C. Prices to be exclusive of all federal, state, local, sales and use taxes. D. All prices to be firm and fixed for the full term of the lease. XII. Billing A. Invoices must be sent to the main enterprise/division address to which it pertains. Refer to Section III.B. B. The complete name of the specific site(s) to which the invoice pertains must be clearly indicated on the invoice. Page 13 of 13

Gas-Detection Instruments

Gas-Detection Instruments ALTAIR 5X Multigas Detector Accessories SPARE PARTS/ REPLACEMENTS CALIBRATION 10114835 Battery pack assembly, rechargeable 10114837 Battery pack, alkaline (includes belt clip) 10114839 Battery pack, rechargeable,

More information

Gas-Detection Instruments

Gas-Detection Instruments Gas-Detection Instruments Regulators Regulators are used to ensure you receive the required flow of calibration gas for your application. MSA regulators save customers money by delivering calibration test

More information

GAS DETECTION: CALIBRATION GAS

GAS DETECTION: CALIBRATION GAS ENVIRONMENTAL SURVEY/PURGING MONITORS GAS DETECTION: CALIBRATION GAS Gas Mixtures Non-Reactive Single & Two-Gas Mixtures 98 Reactive Single & Two-Gas Mixtures 98 Non-Reactive Multi Mixtures 99 Reactive

More information

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc. Advanced Calibration Designs, Inc. Calibration Gas Instrument INSTRUCTION MANUAL Release I www.goacd.com Instruction Manual Gas Generator Release I TABLE OF CONTENTS I. General Description Page 2 II. Start-Up

More information

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Calibration Requirements for Direct Reading Confined Space Gas Detectors : Calibration Requirements for Direct Reading Confined Space Gas Detectors However, the definition of bump test has always been a little slippery. Some manufacturers differentiate between a bump test that

More information

Precision Calibration Gas

Precision Calibration Gas Precision Calibration Gas Setting Standards - Exceeding Expectations GASCO is an organization characterized by integrity, competence, cooperation and professionalism. We continually strive to earn customers

More information

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results. Laboratory Hardware Custom Gas Chromatography Solutions Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions

More information

Spot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements

Spot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements Spot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements Why is Gas Detection Important? Spot the hazard Composition of Fresh

More information

Atmospheric Hazards. Hazardous Atmosphere 3/29/2017. Oxygen deficiency and enrichment Flammable gases and vapors Toxic contaminants

Atmospheric Hazards. Hazardous Atmosphere 3/29/2017. Oxygen deficiency and enrichment Flammable gases and vapors Toxic contaminants 2017 Wisconsin Safety Council Safety & Health Conference, Presentation by Tim Gackle, OSHA Training Institute April 11, 2017 Atmospheric Hazards Oxygen deficiency and enrichment Flammable gases and vapors

More information

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc.

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc. Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED A Division of Norco, Inc. Located in Boise Idaho, Norlab has been producing and distributing calibration gas mixtures and specialty gases in refillable

More information

PRECISION GAS MIXTURES

PRECISION GAS MIXTURES PRECISION GAS MIXTURES 2. Company Profile 3. Reactive Gases 4. Regulators 5. Cylinders 6. Gas Mixtures 7. Accessories PRECISION GAS MIXTURES GASCO Affiliates, LLC is a leading manufacturer of Precision

More information

Nonrefillable Cylinders

Nonrefillable Cylinders Nonrefillable Cylinders A DIVISION OF NORCO, INC. Norlab, the Specialty Gas Division of Norco, Inc., has been producing and distributing calibration mixtures and pure specialty gases in refillable and

More information

Automatic Test and Calibration Station

Automatic Test and Calibration Station Automatic Test and Calibration Station Cost effective calibration and bump test management The MicroDock II is an easy, cost-effective way to bump-test, calibrate, charge and manage records for BW portable

More information

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2. FANs 216, 1628.3 Technical Bulletin CDS4000 Issue Date 0797 CDS4000 CO 2 Sensor Calibration and Troubleshooting Table of Contents Introduction 1 Handling Information 1 Calibration 2 Preparation 2 Cautions

More information

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR) Procedure No: SOP-025 Revision No: 1.0 (January 21, 2011) Page No.: 1 of 8 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting and to

More information

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs. Laboratory Hardware Custom Gas Chromatography Solutions Custom solutions for your analytical needs. Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions for advanced chromatography

More information

Calibration and Bump Test Requirements for Direct Reading Portable Gas Monitors

Calibration and Bump Test Requirements for Direct Reading Portable Gas Monitors : Calibration and Bump Test Requirements for Direct Reading Portable Gas Monitors Manufacturers and regulatory agencies agree the safest and most conservative approach is to perform a functional test by

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) DOCUMENT NO: STP 2203 VERSION: 2008-07-01 Page 1 of 6 1.0 PURPOSE This test procedure is used by the Electrical Safety

More information

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS Using state-of-the-art measuring and microprocessor technologies, Advanced has assembled a series of systems which can measure mass

More information

AND EQUIPMENT FOR ENVIRONMENTAL APPLICATIONS (800) B Polk Street Houston, TX

AND EQUIPMENT FOR ENVIRONMENTAL APPLICATIONS (800) B Polk Street Houston, TX CALIBRATION GASES AND EQUIPMENT FOR ENVIRONMENTAL AND INDUSTRIAL HYGIENE APPLICATIONS (800) 548-2268 6717-B Polk Street Houston, TX 77011 www.portagas.com IS DEDICATED TO PROVIDING INNOVATIVE CALIBRATION

More information

CSA Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual 30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

IRwin Methane Leak Detector. Innovation makes the difference

IRwin Methane Leak Detector. Innovation makes the difference IRwin Methane Leak Detector Innovation makes the difference Innovative methane detector system for easy survey of gas pipelines IRwin is a portable methane leak detector for fast and easy survey of gas

More information

NIT LIMITED NO. NC-105-P-SCS-NOCB CYLINDERS & REGULATORS

NIT LIMITED NO. NC-105-P-SCS-NOCB CYLINDERS & REGULATORS NIT LIMITED NO. CYLINDERS & REGULATORS NATIONAL INSTITUTE OF SCIENCE EDUCATION & RESEARCH JATNI CAMPUS, P.O.: JATNI, Khurdha-752050 Tender Notice No. NIT Limited NO. Sealed Tenders are invited on behalf

More information

Mount Holyoke College. Confined Space Program

Mount Holyoke College. Confined Space Program Mount Holyoke College Confined Space Program November 2014 In Compliance with the OSHA 29 CFR 1910.126 Environmental Health, Safety & Sustainability 413-538-2529 Mount Holyoke College CONFINED SPACE PROGRAM

More information

Using the UltraRAE. Firmware 2.35

Using the UltraRAE. Firmware 2.35 Using the UltraRAE Firmware 2.35 Training Agenda UltraRAE features Setting up the UltraRAE Turning on the UltraRAE Idle Operation RAE-Sep Tubes Prepping for a measurement Taking a measurement Alarm modes

More information

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology: Title: Comparison of Chemical Sensor and NDIR Technologies TSN Number: 25 File:\\MII- SRV1\Metron\Bridge_Analyzers\Customer_Service_Documentation\White_Papers\25_G en EGA NDIR vs Chemical Sensor.docx Created

More information

Phosgene Sensor. Sensoric COCl2 3E 1

Phosgene Sensor. Sensoric COCl2 3E 1 Phosgene Sensor 1 FEATURES Amperometric 3 electrode sensor cell Fixed organic electrolyte High reliability TYPICAL APPLICATIONS Ambient monitoring of TLV levels Chemical Industry, Homeland Security PART

More information

Mount Holyoke College. Confined Space Program

Mount Holyoke College. Confined Space Program Mount Holyoke College Confined Space Program March 2016 In Compliance with the OSHA 29 CFR 1910.126 Environmental Health, Safety & Sustainability 413-538-2529 Mount Holyoke College CONFINED SPACE PROGRAM

More information

The University of Georgia Automated External Defibrillator (AED) Program Guidelines

The University of Georgia Automated External Defibrillator (AED) Program Guidelines The University of Georgia Automated External Defibrillator (AED) Program Guidelines Purpose The University of Georgia (UGA) is committed to providing a safe and healthy environment for all faculty, staff,

More information

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings SomnoSuite FAQ V1.3 January 2015 Setup 1. How do I connect the SomnoSuite to my oxygen source? 2. Is there a way to speed up the downward movement of the pusher block when setting the empty position? 3.

More information

21700 Nordhoff St. Chatsworth, CA Phone

21700 Nordhoff St. Chatsworth, CA Phone 21700 Nordhoff St. Chatsworth, CA. 91311 Phone 818.882.2331 DILUTION SYSTEM DILUTION SYSTEM ~ 1 ~ 09 21 07 TABLE OF CONTENTS DEFINITIONS.. 3 INTRODUCTION.. 4 INSTALLATION & SETUP 5 CONVERSION TO PRESSURE

More information

2018 National Metal and Nonmetal Mine Rescue Contest. Technician Team Competition Written Test (Dräger BG-4) Good Luck!

2018 National Metal and Nonmetal Mine Rescue Contest. Technician Team Competition Written Test (Dräger BG-4) Good Luck! 2018 National Metal and Nonmetal Mine Rescue Contest Technician Team Competition Written Test (Dräger BG-4) Directions: 1. Find the correct answer to each of the questions. 2. Select only one answer per

More information

Grayslake Fire Protection District Request for Self-Contained Breathing Apparatus (SCBA) Bid

Grayslake Fire Protection District Request for Self-Contained Breathing Apparatus (SCBA) Bid Grayslake Fire Protection District Request for Self-Contained Breathing Apparatus (SCBA) Bid The Grayslake Fire Protection District invites interested and qualified parties to submit a bid for a Self-Contained

More information

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet: OXY Integral INTERCON ENTERPRISES INC Tel: 800 665 6655 Fax: 604 946 5340 E-Mail: sales@intercononline.com Internet: www.intercononline.com Manual Integral 2006 1 INDEX 2-3 PREFACE 4 INTRODUCTION 5 Principle

More information

MODEL CALIBRATION GAS DELIVERY SYSTEM

MODEL CALIBRATION GAS DELIVERY SYSTEM MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM APPLICABILITY & EFFECTIVITY This

More information

Bradford Fire Department. Seeks Bids for the Purchase of Self Contained Breathing Apparatus and Related Equipment GENERAL SPECIFICATIONS WARRANTY

Bradford Fire Department. Seeks Bids for the Purchase of Self Contained Breathing Apparatus and Related Equipment GENERAL SPECIFICATIONS WARRANTY Bradford Fire Department Seeks Bids for the Purchase of Self Contained Breathing Apparatus and Related Equipment The Bradford Fire Department seeks Bids to purchase 17 Air-Pak Self Contained Breathing

More information

INDUSTRIAL HYGIENE GROUP Standard Operating Procedure. TVA-1000 PID/FID Portable Toxic Vapor analyzer. 1 of 9. Contents

INDUSTRIAL HYGIENE GROUP Standard Operating Procedure. TVA-1000 PID/FID Portable Toxic Vapor analyzer. 1 of 9. Contents 1 of 9 1.0 Purpose & Scope 2.0 Responsibilities 3.0 Definitions 4.0 Prerequisites 5.0 Precautions 6.0 Procedure 7.0 Implementation And Training 8.0 References 9.0 Attachments 10.0 Documentation Contents

More information

Operation and Maintenance Manual

Operation and Maintenance Manual Operation and Maintenance Manual GDS 49 Remote 4 20mA Sensor Transmitter for Toxic Gases GDS Corp. 1245 Butler Road League City, TX 77573 409 927 2980 409 927 4180 (Fax) www.gdscorp.com CAUTION: FOR SAFETY

More information

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual 30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

CALIBRATION KIT. Instruction Manual

CALIBRATION KIT. Instruction Manual CALIBRATION KIT Instruction Manual 2 CALIBRATION KIT CALIBRATION KIT 3 Table of Contents General description....4 Getting Started....4 GG-NH3....5 GG-NH3-2%....6 GG-CO....7 GG-CO2...8 GG-CL2...9 GG-H2-EC....

More information

Advanced Calibration Designs, Inc. goacd.com. Certified Calibration Gas Solutions

Advanced Calibration Designs, Inc. goacd.com. Certified Calibration Gas Solutions Advanced Calibration Designs, Inc. goacd.com Certified Calibration Gas Solutions Table of Contents We Provide The Ultimate Calibration Gas Solution... 4 How to Buy... 4 CAL2000 Instrument & Accessories...5

More information

SF 6 Product Guide. Gas Analysis Instruments and Accessories

SF 6 Product Guide. Gas Analysis Instruments and Accessories SF 6 Product Guide Gas Analysis Instruments and Accessories Cambridge Sensotec Ltd specialises in the design and manufacture of gas analysis equipment under the Rapidox brand name. Based in the UK, the

More information

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator Procedure No: SOP-034 Revision No: 1.0 Revised Dec. 29, 2010 Page No.: 1 of 10 1. INTRODUCTION AND SCOPE This procedure is intended to describe the operations of the Dasibi model 5008 calibrator. The Dasibi

More information

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Oxygen Measurement Systems High Reliability and Wide Application Coverage Introduction High Process Efficiency Under Any Condition Oxygen Measurement Systems High Reliability and Wide Application Coverage METTLER TOLEDO provides sensors to measure dissolved oxygen (DO) in demanding

More information

Solaris Nitrogen. Installation Guide. Solaris Nitrogen Installation Guide Rev 1 PN IG /09/16

Solaris Nitrogen. Installation Guide. Solaris Nitrogen Installation Guide Rev 1 PN IG /09/16 Solaris Nitrogen Installation Guide Solaris Nitrogen Installation Guide Rev 1 PN IG-0014 01/09/16 Change History Rev Comment Name Date How to use this Manual This installation guide is intended to be used

More information

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Specification Bulletin (rev.01) Series CH4200 Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Easy, fast& accurate digital with 11 points calibration Laser sensor offering actual feed

More information

Energy Management solutions for compressed air and industrial gases. vpinstruments.com

Energy Management solutions for compressed air and industrial gases. vpinstruments.com Energy Management solutions for compressed air and industrial gases vpinstruments.com 6 Introduction VPINSTRUMENTS Measure, Discover and Save! Compressed air is a very expensive energy source. In fact,

More information

Documentation Beats Confrontation in Gas Detection

Documentation Beats Confrontation in Gas Detection Session No. 770 Documentation Beats Confrontation in Gas Detection Andrew Saunders, CQT Applications and Training Specialist BW Technologies by Honeywell Introduction Deaths of workers in confined spaces

More information

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator Procedure No: SOP-029 Revision No: 1.1 (December 29, 2010) Page No.: 1 of 7 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality

More information

PUBLIC COMPANY ORLEN LIETUVA OCCUPATIONAL HEALTH AND SAFETY PROCEDURE BDS-12 USE OF PORTABLE GAS ANALYZERS I. GENERAL

PUBLIC COMPANY ORLEN LIETUVA OCCUPATIONAL HEALTH AND SAFETY PROCEDURE BDS-12 USE OF PORTABLE GAS ANALYZERS I. GENERAL PUBLIC COMPANY ORLEN LIETUVA APPROVED BY Deputy Director of Quality, Labor Safety and Environmental Control Director 30 November 2017 Order No TV1(1.2-1)-457 OCCUPATIONAL HEALTH AND SAFETY PROCEDURE BDS-12

More information

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司 X-Flow Mass Flow Controller 2 Highlights Parker Hannifin Precision Fluidics Division is excited to introduce X-Flow, a new easy to use general purpose mass flow controller for your instrument, lab, or

More information

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane Gas requirements Gases for packed columns The carrier gas you use depends upon the type of detector and the performance requirements. Table 520-1 lists gas recommendations for packed column use. In general,

More information

Do Not Print This Page.

Do Not Print This Page. Do Not Print This Page. Load 1 sheet of cardstock paper. Print Page 2 - the cover For the body of the text, load 3 sheets of 28lb matte finish paper into the printer. Print pages 3, 5, 7 (Sheet 1, 2, 3)

More information

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C EXPIRATION DATE: June 30, 2015

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C EXPIRATION DATE: June 30, 2015 November 14, 2014 East Building, PHH-30 U.S. Department 1200 New Jersey Avenue S.E. of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety Administration DOT-SP 16219 EXPIRATION

More information

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental

More information

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)

More information

Ozone. Sensoric O3 3E 1

Ozone. Sensoric O3 3E 1 Ozone Sensoric O3 3E 1 1 FEATURES Amperometric 3 electrode sensor cell Long life time High reliability High resolution Fast response time Fixed organic gel electrolyte TYPICAL APPLICATIONS Environmental

More information

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question.

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question. Chapter 15 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Distinguish among preperformance tests for pumping apparatus. 1. Which standard is commonly

More information

c) Loss of product or replacement when units are being serviced All of these are factors that need to be considered by the user.

c) Loss of product or replacement when units are being serviced All of these are factors that need to be considered by the user. GAS DETECTION Cost of Ownership In today's competitive marketplace the initial cost of any capital equipment is important to the end user but of equal importance is the ongoing cost of ownership. In many

More information

Rimage Everest 600 Thermal Retransfer Printer

Rimage Everest 600 Thermal Retransfer Printer Rimage Everest 600 Thermal Retransfer Printer Superior Print Technology: Superior Results CONTENTS I. Overview II. Printer Comparison III. Print Modes IV. Advantages of Thermal Retransfer Printing V. Printer

More information

Verification Of Calibration for Direct-Reading Portable Gas Monitors

Verification Of Calibration for Direct-Reading Portable Gas Monitors U. S. Department of Labor Occupational Safety and Health Administration Directorate of Science, Technology and Medicine Office of Science and Technology Assessment Verification Of Calibration for Direct-Reading

More information

490 Micro GC Site Preparation Checklist

490 Micro GC Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN METRIC 17 May 2013 SUPERSEDING MIL-PRF-27201D 07 February 2007 PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN This specification is approved for use by all Departments and Agencies of the Department of

More information

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation Page 1 of 19 : SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor Description and Principle of Operation The photoacoustic multi-gas monitor (INNOVA 1412, Innova AirTech Instruments, Denmark) is a highly

More information

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions

More information

Vehicle and Engine Emissions Testing

Vehicle and Engine Emissions Testing Vehicle and Engine Emissions Testing Calibration gases and equipment for compliance Benefits and Features Guaranteed analytical accuracy facilitates precise instrument calibration to ensure Part 1065,

More information

Model Description

Model Description LEAKHUNTER Plus LEAKHUNTER Plus Model 8066 Description The MATHESON LEAKHUNTER Plus is a truly universal leak detector. Extensive R&D has produced a multi-functional leak detector engineered to perform

More information

TENDER SPECIFICATION No: 12/ of SUPERINTENDING ENGINEER (CTI & ENQUIRIES), Dt

TENDER SPECIFICATION No: 12/ of SUPERINTENDING ENGINEER (CTI & ENQUIRIES), Dt 1 TENDER SPECIFICATION No: 12/2018-19 of SUPERINTENDING ENGINEER (CTI & ENQUIRIES), Dt. 08.01.2019 Specification for Supply of Standard Calibration Gas Mixture in the ranges of 5PPM and 100PPM filled in

More information

These Terms and conditions apply to audit trails incorporated in weighing and measuring devices and systems 1.

These Terms and conditions apply to audit trails incorporated in weighing and measuring devices and systems 1. Title: Terms and Conditions for the Approval of Metrological Audit Trails Effective Date: 2006-03-16 Page: 1 of 9 Revision: 1.0 Application These Terms and conditions apply to audit trails incorporated

More information

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2 GAS ANALYSER OXYBABY 6.0 for or Cordless hand held oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for portable, faster and accurate

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

ACV-10 Automatic Control Valve

ACV-10 Automatic Control Valve ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,

More information

Air Monitor Calibration, Bump Testing, and Sensor Challenge

Air Monitor Calibration, Bump Testing, and Sensor Challenge Air Monitor Calibration, Bump Testing, and Sensor Challenge These come under the heading of life safety and mission-critical considerations. By James R. MacNeal Oct 01, 2006 THERE is no better way to ruin

More information

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions

More information

GasLab SAN-102 Micro Oxygen Monitor User Manual

GasLab SAN-102 Micro Oxygen Monitor User Manual GasLab SAN-102 Micro Oxygen Monitor User Manual The GasLab SAN-102 is a wearable, personal safety meter designed to monitor ambient oxygen levels in real time. It is designed to protect workers in confined

More information

PERFORM Operating Document

PERFORM Operating Document PERFORM Operating Document Use and Maintenance of CO 2 Incubator PC-POD-CA-007-v03 Revision History Version Reason for Revision Date 01 New POD 30-Sep-13 02 Minor revisions for section 2.3, 3.1, 4.3. 14-April-16

More information

BUYER S GUIDE AQUAlogger 530WTD

BUYER S GUIDE AQUAlogger 530WTD OCEAN & ENVIRONMENTAL BUYER S GUIDE AQUAlogger 530WTD Wireless Temperature and Depth Logger AQUAlogger 530WTD The AQUAlogger 530WTD has an innovative design that includes the ability to transfer stored

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD) Procedure No: SOP-026 Revision No: 1.0 January 24, 2011 Page No.: 1 of 10 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting and to meet

More information

Describe Flammable Gas Measurement

Describe Flammable Gas Measurement Training Module Describe Flammable 100% 90% C 80% No Combustion 70% 60% 50% 40% 30% 20% UEL B Combustion No Combustion 10% 0% LEL A Human Development HDC Human Development All rights reserved. No part

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50 Rev.02 (2014.06) OL Page 1 of 8 Table of contents I. STRUCTURE OF THE MANUAL / CLARIFICATION... 3 II. SAFETY AND HEALTH CONCERNS... 4 1 INTRODUCTION... 5 1.1 Use

More information

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021-PR Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-PR For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4

More information

DPC-30 DPC-100. Reference Manual

DPC-30 DPC-100. Reference Manual DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,

More information

SCIENCE LAB UTILITY CONTROLS

SCIENCE LAB UTILITY CONTROLS SCIENCE LAB UTILITY CONTROLS INCORPORATING GAS PRESSURE PROVING GAS PRESSURE PROVING EQUIPMENT - ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY THE MERLIN RANGE DESIGNED FOR EDUCATIONAL LABORATORIES

More information

A. Evaluation of the written program

A. Evaluation of the written program A. Evaluation of the written program Begin your audit with an evaluation of the written respiratory protection program. In addition to the operating procedures describing respirator selection and use in

More information

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features Features Pressure ranges from 0 to 5 and 0 to 3000 psi (0 to 400 mbar and 0 to 210 bar) xi and 7250i provide advanced precision of 0.005% of reading provides 0.003% of full scale precision Stability: 0.0075%

More information

780S Ultra High Purity Series

780S Ultra High Purity Series Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board

More information

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators Selection Guide / Process Calibration Equipment Automated Calibrators Selection Guide Model Features Range Module 1 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP -2.5 to 2.5 mbar (-1 to 1 inh 2 O) -0.95

More information

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1 Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost HERMAN HOLM SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 4C CONFERENCE APRIL 2018 SAN ANTONIO, TX SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC

More information

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet Data sheet MEGAS 2.0 Gas analysis with direct C-Level Calculation and Bus-Connection Mesa Industrie-Elektronik GmbH Neckarstraße 19, D-45768 Marl info@mesa-gmbh.de +49 (0) 2365-97 45 1-0 +49 (0) 2365-97

More information

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A 2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A PROJECT ADDRESS TESTING AUTHORITY TELEPHONE Checked by/date Enforcement Agency Use GENERAL INFORMATION OF BLDG. PERMIT PERMIT # BLDG. CONDITIONED FLOOR

More information

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM 40 Series Extractive Gas Analyser CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O Extractive low cost, low maintenance devices for continuous

More information

SAFETY FIRST. TESTED EQUIPMENT FOR OPTIMAL PROTECTION. DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES S.

SAFETY FIRST. TESTED EQUIPMENT FOR OPTIMAL PROTECTION. DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES S. S. 00 00 ST-5619-2005 ST-2786-2003. TESTED EQUIPMENT FOR OPTIMAL PROTECTION. DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES VAPOUR CALIBRATION AND MORE. Vapour calibration and

More information

Because every life has a purpose. MSA Z GARD S Sensor Calibration Procedure

Because every life has a purpose. MSA Z GARD S Sensor Calibration Procedure MSA Z GARD S Sensor Calibration Procedure MSA 2012 Calibration Procedure for a Z GARD S Sensor The following is a step-by-step procedure for calibrating a Z-Gard S sensor produced after December 2013 You

More information

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators Selection Guide Automated Calibrators Selection Guide Model Features Range 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP 0.05 to 8 bar.a -0.90 to 25 bar (1.2 to 115 psi.a) (-13 to 375 psi) 0.1 to 26 bar.a

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure

More information

User s Guide Temperature Sensor Converter TSC-599

User s Guide Temperature Sensor Converter TSC-599 User s Guide Temperature Sensor Converter TSC-599 ILX Lightwave Corporation 31950 Frontage Road Bozeman, MT, U.S.A. 59715 U.S. & Canada: 1-800-459-9459 International Inquiries: 406-556-2481 Fax 406-586-9405

More information

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Additel 761 Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure modules Built-in

More information