GAS DETECTION: CALIBRATION GAS

Size: px
Start display at page:

Download "GAS DETECTION: CALIBRATION GAS"

Transcription

1 ENVIRONMENTAL SURVEY/PURGING MONITORS GAS DETECTION: CALIBRATION GAS Gas Mixtures Non-Reactive Single & Two-Gas Mixtures 98 Reactive Single & Two-Gas Mixtures 98 Non-Reactive Multi Mixtures 99 Reactive Multi Mixtures 99 Bump Gas 100 BumpIt 100 Information Precision Gas Mixtures 100 Cylinder Information 101 EcoSmart Refillable Cylinders 102 Accessories Cases & Kits 103 Regulators

2 GAS DETECTION: CALIBRATION GAS Gas Mixtures Non-Reactive Single & Two-Gas Mixtures Reactive Single & Two-Gas Mixtures PART NUMBER (SUFFIX) TARGET GAS CONCN. BALANCE Benzene 5 ppm Air Carbon Monoxide 200 ppm Air Carbon Monoxide 100 ppm Air Carbon Monoxide 50 ppm Air Carbon Monoxide 35 ppm Air Carbon Monoxide 250 ppm Air Carbon Dioxide 2.5 % vol. Nitrogen Carbon Dioxide 1000 ppm Nitrogen Carbon Dioxide 2000 ppm Nitrogen Carbon Dioxide 5000 ppm Nitrogen -62A-50 Ethylene 50 ppm Air Hexane 400 ppm Air Hexane 0.48% vol. Air Hydrogen 2% vol. Air Isobutylene 10 ppm Air Isobutylene 100 ppm Air -135A-2.5 Methane 50% LEL Air -135N Methane 50% vol. Nitrogen -135A-0.5 Methane 10% LEL Air *34LA-132 Methane 100% vol. n/a -114 Nitrogen % vol. n/a Pentane.79% Vol. 50% LEL Air Pentane.35% Vol. 25% LEL Air Propane 1.05% Vol. 50% LEL Air -1 Zero Air 20.9% vol. Nitrogen Non-Reactive Single and Two-Gas Mixtures may be purchased in the following cylinders: CYLINDER TYPE P/N PREFIX USE WITH REGULATOR 17 Litre 17L 71 Series or 2007 DFR 34 Litre 34LS 71 Series or 2007 DFR 105 Litre 105L 70 Series or 2001 DFR PART NUMBER (SUFFIX) TARGET GAS CONCN. BALANCE Ammonia 25 ppm Nitrogen Ammonia 25 ppm Air Ammonia 50 ppm Air Chlorine 5 ppm Nitrogen Chlorine 10 ppm Nitrogen -HCN-5 Hydrogen Cyanide 5 ppm Nitrogen -HCN-10 Hydrogen Cyanide 10 ppm Nitrogen -HCL-5 Hydrogen Chloride 5 ppm Nitrogen -HCL-10 Hydrogen Chloride 10 ppm Nitrogen Hydrogen Sulfide 50 ppm Nitrogen Hydrogen Sulfide 50 ppm Air Hydrogen Sulfide 25 ppm Nitrogen Hydrogen Sulfide 5 ppm Nitrogen Hydrogen Sulfide 15 ppm Nitrogen Hydrogen Sulfide 20 ppm Nitrogen Hydrogen Sulfide 35 ppm Nitrogen Hydrogen Sulfide 40 ppm Nitrogen Hydrogen Sulfide 100 ppm Nitrogen Hydrogen Sulfide 200 ppm Nitrogen Hydrogen Sulfide 25 ppm Air Hydrogen Sulfide 10 ppm Air Hydrogen Sulfide 10 ppm Nitrogen Nitrogen Dioxide 100 ppm Air Nitrogen Dioxide 10 ppm Air Nitrogen Dioxide 5 ppm Air Sulfur Dioxide 5 ppm Nitrogen Sulfur Dioxide 10 ppm Nitrogen Sulfur Dioxide 25 ppm Nitrogen Sulfur Dioxide 50 ppm Nitrogen Sulfur Dioxide 100 ppm Nitrogen Reactive Multi Mixtures may be purchased in the following cylinders: CYLINDER TYPE P/N PREFIX USE WITH REGULATOR 34 Litre 34L 70 Series or 2001 DFR 58 Litre 58L 70 Series or 2001 DFR 74 Litre 74L 70 Series or 2001 DFR 116L 70 Series or 2001 DFR 98

3 GAS MIXTURES Non-Reactive Multi Mixtures PART NUMBER (SUFFIX) CARBON MONOXIDE METHANE PENTANE OXYGEN BALANCE COMPANY ppm 50% LEL Air Draeger ppm 30% LEL Air Draeger ppm 50% LEL 19% Nitrogen Dynamation % LEL 25% LEL Nitrogen ISC ppm 50% LEL 17% Nitrogen Quest ppm 50% LEL 12% Nitrogen GasTech ppm 50% LEL 17% Nitrogen ppm 10% LEL 18% Nitrogen ppm 50% LEL 15% Nitrogen ppm 50% LEL 12% Nitrogen Reactive Multi Mixtures PART NUMBER METHANE PENTANE PROPANE CARBON MONOXIDE HYDROGEN SULFIDE OXYGEN BALANCE COMPANY % LEL 100 ppm 25 ppm 20.9% Nitrogen BW % LEL 50 ppm 25 ppm 12% Nitrogen GasTech / RKI % LEL 100 ppm 25 ppm 18% Nitrogen BW (dock. stn.) % LEL 100 ppm 25 ppm 19% Nitrogen ISC % LEL 50 ppm 25 ppm 18% Nitrogen Bio-Systems % LEL 50 ppm 25 ppm 20.9% Nitrogen RAE Systems % LEL 50 ppm 10 ppm 20.9% Nitrogen RAE Systems % LEL 300 ppm 10 ppm 15% Nitrogen MSA % LEL 50 ppm 25 ppm 19% Nitrogen % LEL 25 ppm 19% Nitrogen ISC % LEL 100 ppm 25 ppm 19% Nitrogen ISC % LEL 35 ppm 10 ppm 18% Nitrogen AIM % LEL 50 ppm 25 ppm 12% Nitrogen GasTech (Pent.) % LEL 50 ppm 25 ppm 12% Nitrogen GasTech (Pent.) % LEL 100 ppm 25 ppm 18% Nitrogen BW (Pentane) % LEL 100 ppm 25 ppm 20.9% Nitrogen BW (Pentane) -403E 50% LEL 50 ppm 25 ppm 18% Nitrogen Bio-Systems % LEL 100 ppm 25 ppm 20.9% Nitrogen Non-Reactive Multi Mixtures may be purchased in the following cylinders: CYLINDER TYPE P/N PREFIX USE WITH REGULATOR 17 Litre 17L 71 Series or 2007 DFR 34 Litre 34LS 71 Series or 2007 DFR 105 Litre 105L 70 Series or 2001 DFR Reactive Multi Mixtures may be purchased in the following cylinders: CYLINDER TYPE P/N PREFIX USE WITH REGULATOR 34 Litre 34L 70 Series or 2001 DFR 58 Litre 58L 70 Series or 2001 DFR 74 Litre 74L 70 Series or 2001 DFR 116L 70 Series or 2001 DFR 99

4 GAS DETECTION: CALIBRATION GAS Bump Gas PART NO. CH4 CO H2S O2 BAL. 10L-490-T 50% LEL 200 ppm 40 ppm 10% Nitrogen 10L % LEL 100 ppm 60 ppm 13% 10L % LEL Air ppm Nitrogen BumpIt Make sure your gas detector works! BumpIt is a disposable 6 mini gas cylinder designed for bump testing portable gas monitors, gas sensors, or fixed gas detection equipment. Non-aerosol, non-flammable and low pressure five second bumps per cylinder No regulator needed Many mixes available: Call for available gases Information Precision Gas Mixtures SIZE GAS BALANCE SHELF LIFE 17 & 34 Litre Non-Reactive Air or Nitrogen 48 Months 105 Litre Non-Reactive Air or Nitrogen 48 Months 221 Litre Non-Reactive Air or Nitrogen 48 Months 552 Litre Non-Reactive Air or Nitrogen 48 Months Sulfur Dioxide Air or Nitrogen 15 Months Hydrogen Sulfide Air or Nitrogen 15 Months The Importance of Bump Testing Gas monitoring instruments are designed to protect personnel from unseen hazards that may exist in workplace environments, including confined spaces. It is vital to worker safety that these instruments are maintained and calibrated properly. Instrument inaccuracy due to improper or irregular calibration can lead to serious accidents. Exposure to excessive levels of toxic gas or an oxygen-deficient environment can cause workers serious illness and even death. Combustible gas explosions are often catastrophic, injuring or killing personnel and destroying property. The only way to guarantee that an instrument will detect gas accurately and reliably is to test it with a known concentration of gas. Exposing the instrument to a known concentration of test gas will show whether the sensors respond accurately and whether the instrument alarms function properly. DEFINITION: QUICK CHECK The brief exposure of the monitor to gas at concentrations higher than those of the low-alarm set-points to test the functionality of the monitor. Ammonia Air or Nitrogen 12 Months Hydrogen Cyanide Nitrogen 12 Months Chlorine Nitrogen 12 Months Hydrogen Chloride Nitrogen 12 Months Nitrogen Oxide Nitrogen 12 Months Nitrogen Dioxide Air 12 Months Phosphine Nitrogen 12 Months Silane Nitrogen 12 Months Ethylene Oxide Nitrogen 12 Months Four-Gas Mix Air or Nitrogen 15 Months DEFINITION: BUMP TEST The brief exposure of the monitor to a known concentration of gas (exceeding the low-alarm set-point) for each sensor. The instrument reading is then compared against the reference point of the last calibration and if it is within an acceptable range (normally 10%) its calibration can be considered accurate. 10 Litre Hydrogen Sulfide Air or Nitrogen 6 Months DEFINITION: CALIBRATION Calibration refers to an instrument s measuring accuracy relative to a known concentration of gas. Gas detectors measure the concentration of a gas in an air sample by comparing the sensor s response to the response generated by a calibration gas of a known concentration. The instrument s response to the calibration gas serves as the measurement scale or reference point

5 INFORMATION Cylinder Information CYLINDER CONTENTS DIMENSIONS MATERIAL WATER CAPACITY WEIGHT VALVE INLET TRANSPORT REGULATOR REQUIRED 552L 552 litres (19.4 cu F & x 4.5 Steel 3.69 Litres 11 lbs. Gas Specific N/A 221L 221 litres (8.0 cu F & x 9.0 Steel 12 Litres 6.3 lbs. CGA series w/ adapter 116L 116 litres (4.0 cu F & x 3.5 Aluminum 1.72 Litres 2.1 lbs. 5/ L 105 litres (3.6 cu F & x 3.3 Steel 1.52 Litres 3 lbs. 5/ L 74 litres (2.6 cu F & x 4.25 Aluminum 2.2 Litres 2.3 lbs. 5/ L 58 litres (2.0 cu F & x 3.5 Aluminum 1.72 Litres 1.75 lbs. 5/ L 34 litres (1.2 cu F & x Aluminum 0.9 Litres 1.9 lbs. 5/ LS 34 litres (1.2 cu F & x 2.9 Steel 0.9 Litres 1.5 lbs. CGA series 71 CVA 17L 17 litres (0.6 cu F & x 2.9 Steel 1 Litre 1 lb. CGA series 71 CVA 10L 10 litres (0.35 cu F & x 2.9 Aluminum 0.97 Litres 0.3 lbs 7/16 28NS/2 male Spray Nozzle 101

6 GAS DETECTION: CALIBRATION GAS EcoSmart Refillable Cylinders NEW Concept Controls and Gasco are taking responsibility for the impact our products have on the environment. Exclusive EcoSmart cylinders are coupled with innovative measures which enable you to reuse and refill your gas cylinder. Gasco employs proprietary procedures to create the highest quality grades of pure gases and gas mixtures bringing us to the forefront of this technology. Plus, EcoSmart cylinders are available at no additional cost. The price remains the same as in a throw away! Features: Refillable Portable Lightweight Increases efficiency Holds pure and mixed gases Eliminates disposal fees and regulatory paperwork Part Number 44 ES 58 ES 66 ES 116 ES 650 ES Pressure 825 PSI 1000 PSI 1200 PSI 1000 PSI 1650 PSI Gas Type Dimensions 9.8" x 2.9" 9.8" x 2.9" 10.5" x 2.9" 14.3" x 3.5" 5.25" x 19.25" Water Capacity 0.79 Litres 0.79 Litres 0.79 Litres 1.7 Litres 5.77 Litres Material Aluminum alloy Aluminum alloy Aluminum alloy Aluminum alloy Aluminum alloy Weight 1.7 lbs 1.7 lbs 1.7 lbs 2 lbs 15.8 lbs with valve Valve Inlet 5/8-18 5/8-18 5/8-18 5/8-18 CGA 330 valve Regulator Demand Flow, 70 Series, 70-SS Series Demand Flow, 70 Series, 70-SS Series Demand Flow, 70 Series, 70-SS Series 70 Series, 70-SS Series 75 DFR/330 Contents 1.5 cu.ft cu.ft cu.ft. 4 cu.ft cu.ft

7 ACCESSORIES Accessories Cases & Kits CASES 574 GD-HPCC Teal Calibration Case Holds (2) 58L 3 Cylinder Soft-Sided Carry Case Black Plastic Case Holds 17 & 34 Litre KITS KG34L KG34L KG58L Bump Test Kit Includes: Black Carrying Case, Bump Gas (34L-421), 0.2 LPM Trigger Reg., Tygon Tubing Concept Calibration Kit Includes: Black Carrying Case, Cal. Gas (34L-404), 0.5 LPM Reg., Tygon Tubing Concept Calibration Kit Includes: Teal Calibration Case, Cal. Gas (58L-404), 0.5 LPM Reg., Tygon Tubing Kits can be manufactured to meet any specific need 103

8 GAS DETECTION: CALIBRATION GAS Regulators 17L & 34LS REGULATORS Part Number 71-* 76-Q71-* CV-2 Valve Inlet CGA 600 CGA 600 CGA 600 Flow Rate LPM Fixed LPM Fixed N/A Gauge PSI 600 PSI N/A N/A Material Aluminum or Brass 34L, 58L, 74L,105L, & 116L REGULATORS Part Number 74 DAF 70 & 70/SS-* 75 DFR Valve Inlet C-10 C-10 C-10 Flow Rate 0.3-3LPM Selectable LPM Fixed On-Demand Gauge PSI 1200 PSI 1200 PSI 1200 PSI Material or Stainless Steel 17L, 34L, 34LS, 58L, 74L, 105L, & 116L REGULATORS Part Number FMV 70-TR IGGER Valve Inlet CGA-600 C-10 or CGA 600 C-10 or CGA 600 Flow Rate On-Demand Flow-Matching LPM Fixed Gauge PSI 1200 PSI 1200 PSI 1200 PSI Material Brass 104

PRECISION GAS MIXTURES

PRECISION GAS MIXTURES PRECISION GAS MIXTURES 2. Company Profile 3. Reactive Gases 4. Regulators 5. Cylinders 6. Gas Mixtures 7. Accessories PRECISION GAS MIXTURES GASCO Affiliates, LLC is a leading manufacturer of Precision

More information

Precision Calibration Gas

Precision Calibration Gas Precision Calibration Gas Setting Standards - Exceeding Expectations GASCO is an organization characterized by integrity, competence, cooperation and professionalism. We continually strive to earn customers

More information

Calibration Gases. Intrial provides mix of special calibration gases for analyzers and detectors.

Calibration Gases. Intrial provides mix of special calibration gases for analyzers and detectors. Intrial provides mix of special calibration gases for analyzers and detectors. Introduction Mixing of Standard Gases for Calibration of Analyzers and Detectors INTRIAL is the leading and only independent

More information

Calibration Gases. Intrial provides mix of special calibration gases for analyzers and detectors.

Calibration Gases. Intrial provides mix of special calibration gases for analyzers and detectors. Intrial provides mix of special calibration gases for analyzers and detectors. Introduction Mixing of Standard Gases for Calibration of Analyzers and Detectors INTRIAL is the leading and only independent

More information

Gas-Detection Instruments

Gas-Detection Instruments Gas-Detection Instruments Regulators Regulators are used to ensure you receive the required flow of calibration gas for your application. MSA regulators save customers money by delivering calibration test

More information

AND EQUIPMENT FOR ENVIRONMENTAL APPLICATIONS (800) B Polk Street Houston, TX

AND EQUIPMENT FOR ENVIRONMENTAL APPLICATIONS (800) B Polk Street Houston, TX CALIBRATION GASES AND EQUIPMENT FOR ENVIRONMENTAL AND INDUSTRIAL HYGIENE APPLICATIONS (800) 548-2268 6717-B Polk Street Houston, TX 77011 www.portagas.com IS DEDICATED TO PROVIDING INNOVATIVE CALIBRATION

More information

Gas-Detection Instruments

Gas-Detection Instruments ALTAIR 5X Multigas Detector Accessories SPARE PARTS/ REPLACEMENTS CALIBRATION 10114835 Battery pack assembly, rechargeable 10114837 Battery pack, alkaline (includes belt clip) 10114839 Battery pack, rechargeable,

More information

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc.

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc. Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED A Division of Norco, Inc. Located in Boise Idaho, Norlab has been producing and distributing calibration gas mixtures and specialty gases in refillable

More information

Automatic Test and Calibration Station

Automatic Test and Calibration Station Automatic Test and Calibration Station Cost effective calibration and bump test management The MicroDock II is an easy, cost-effective way to bump-test, calibrate, charge and manage records for BW portable

More information

Nonrefillable Cylinders

Nonrefillable Cylinders Nonrefillable Cylinders A DIVISION OF NORCO, INC. Norlab, the Specialty Gas Division of Norco, Inc., has been producing and distributing calibration mixtures and pure specialty gases in refillable and

More information

Verification Of Calibration for Direct-Reading Portable Gas Monitors

Verification Of Calibration for Direct-Reading Portable Gas Monitors U. S. Department of Labor Occupational Safety and Health Administration Directorate of Science, Technology and Medicine Office of Science and Technology Assessment Verification Of Calibration for Direct-Reading

More information

Non-refillable canister solutions for ultimate portability

Non-refillable canister solutions for ultimate portability Non-refillable canister solutions for ultimate portability Making the difference Air Products has been serving customers in the analytical, testing and calibration markets for decades. Through these close

More information

GASES FIRE & RESCUE SPECIALTY. Gases & Equipment. Medical Gases Liquid & High Pressure Oxygen U.S.P. Nitrogen N.F. Carbon Dioxide U.S.P.

GASES FIRE & RESCUE SPECIALTY. Gases & Equipment. Medical Gases Liquid & High Pressure Oxygen U.S.P. Nitrogen N.F. Carbon Dioxide U.S.P. FIRE & RESCUE Gases & Equipment Medical Gases Liquid & High Pressure Oxygen U.S.P. Nitrogen N.F. Carbon Dioxide U.S.P. Zero Air Methane Carbon Monoxide SPECIALTY GASES 061113 Total Support... our business

More information

Technical Manual. Sensepoint XCD Gas Detector

Technical Manual. Sensepoint XCD Gas Detector Technical Manual Sensepoint XCD Gas Detector 19 Cross Interference and Cross Calibration 19.1 Cross Interference Table for Toxic and Oxygen This table shows the relative cross sensitivity of the Sensepoint

More information

Applications Note: Use of "pentane equivalent" calibration gas mixtures

Applications Note: Use of pentane equivalent calibration gas mixtures Introduction The gas that is used to verify accuracy is every bit as important as the detector itself when it comes to worker safety. Choosing (and using) the right mixture is critical to the success of

More information

Gas Mixture Two Components. Gas Mixtures Two Components

Gas Mixture Two Components. Gas Mixtures Two Components Gas Mixture Two Components Two Components Contents Two-Component Mixtures Ammonia...M4 Argon...M5 Benzene...M6 n-butane...m7 Carbon Dioxide...M8 Carbon Monoxide...M10 Chlorine...M12 Ethane...M13 Ethylene

More information

SAFETY FIRST. TESTED EQUIPMENT FOR OPTIMAL PROTECTION. DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES S.

SAFETY FIRST. TESTED EQUIPMENT FOR OPTIMAL PROTECTION. DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES S. S. 00 00 ST-5619-2005 ST-2786-2003. TESTED EQUIPMENT FOR OPTIMAL PROTECTION. DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES VAPOUR CALIBRATION AND MORE. Vapour calibration and

More information

Lecture Bottles Purchase & Disposal

Lecture Bottles Purchase & Disposal Lecture Bottles Purchase & Disposal Lecture bottles are small compressed gas cylinders, typically 2-3 inches in diameter and 12-18 inches in height. While most gas suppliers offer lecture bottles for purchase

More information

Operation and Maintenance Manual

Operation and Maintenance Manual Operation and Maintenance Manual GDS 49 Remote 4 20mA Sensor Transmitter for Toxic Gases GDS Corp. 1245 Butler Road League City, TX 77573 409 927 2980 409 927 4180 (Fax) www.gdscorp.com CAUTION: FOR SAFETY

More information

IRwin Methane Leak Detector. Innovation makes the difference

IRwin Methane Leak Detector. Innovation makes the difference IRwin Methane Leak Detector Innovation makes the difference Innovative methane detector system for easy survey of gas pipelines IRwin is a portable methane leak detector for fast and easy survey of gas

More information

Phosgene Sensor. Sensoric COCl2 3E 1

Phosgene Sensor. Sensoric COCl2 3E 1 Phosgene Sensor 1 FEATURES Amperometric 3 electrode sensor cell Fixed organic electrolyte High reliability TYPICAL APPLICATIONS Ambient monitoring of TLV levels Chemical Industry, Homeland Security PART

More information

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Calibration Requirements for Direct Reading Confined Space Gas Detectors : Calibration Requirements for Direct Reading Confined Space Gas Detectors However, the definition of bump test has always been a little slippery. Some manufacturers differentiate between a bump test that

More information

Atmospheric Hazards. Hazardous Atmosphere 3/29/2017. Oxygen deficiency and enrichment Flammable gases and vapors Toxic contaminants

Atmospheric Hazards. Hazardous Atmosphere 3/29/2017. Oxygen deficiency and enrichment Flammable gases and vapors Toxic contaminants 2017 Wisconsin Safety Council Safety & Health Conference, Presentation by Tim Gackle, OSHA Training Institute April 11, 2017 Atmospheric Hazards Oxygen deficiency and enrichment Flammable gases and vapors

More information

Misuse of Combustible Gas Meters

Misuse of Combustible Gas Meters Misuse of Combustible Gas Meters An incident investigation raised concerns that users of combustible gas meters may be greatly underestimating fire and explosion hazards. Errors result when meters calibrated

More information

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS Using state-of-the-art measuring and microprocessor technologies, Advanced has assembled a series of systems which can measure mass

More information

MODEL CALIBRATION GAS DELIVERY SYSTEM

MODEL CALIBRATION GAS DELIVERY SYSTEM MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM APPLICABILITY & EFFECTIVITY This

More information

Because every life has a purpose. MSA Z GARD S Sensor Calibration Procedure

Because every life has a purpose. MSA Z GARD S Sensor Calibration Procedure MSA Z GARD S Sensor Calibration Procedure MSA 2012 Calibration Procedure for a Z GARD S Sensor The following is a step-by-step procedure for calibrating a Z-Gard S sensor produced after December 2013 You

More information

CSA Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual 30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

Sensepoint XCD. Calibration Guide

Sensepoint XCD. Calibration Guide Sensepoint XCD Calibration Guide Sensepoint XCD Calibration Calibration Handbook It is recommended to periodically carry out a gas response check on the Sensepoint XCD to ensure correct operation. This

More information

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual 30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

Advanced Calibration Designs, Inc. goacd.com. Certified Calibration Gas Solutions

Advanced Calibration Designs, Inc. goacd.com. Certified Calibration Gas Solutions Advanced Calibration Designs, Inc. goacd.com Certified Calibration Gas Solutions Table of Contents We Provide The Ultimate Calibration Gas Solution... 4 How to Buy... 4 CAL2000 Instrument & Accessories...5

More information

ITEMS REQUIRED TO CALIBRATE A STANDARD GAS DETECTOR USING A 34L, 58L, 78L OR 103L CYLINDER OF GAS:

ITEMS REQUIRED TO CALIBRATE A STANDARD GAS DETECTOR USING A 34L, 58L, 78L OR 103L CYLINDER OF GAS: Standard Calibration ITEMS REQUIRED TO CALIBRATE A STANDARD GAS DETECTOR USING A 34L, 58L, 78L OR 103L CYLINDER OF GAS: Grey calibration adapter plug with o-ring and two zeroing port nozzles. Fits industry

More information

Describe Flammable Gas Measurement

Describe Flammable Gas Measurement Training Module Describe Flammable 100% 90% C 80% No Combustion 70% 60% 50% 40% 30% 20% UEL B Combustion No Combustion 10% 0% LEL A Human Development HDC Human Development All rights reserved. No part

More information

Calibration and Bump Test Requirements for Direct Reading Portable Gas Monitors

Calibration and Bump Test Requirements for Direct Reading Portable Gas Monitors : Calibration and Bump Test Requirements for Direct Reading Portable Gas Monitors Manufacturers and regulatory agencies agree the safest and most conservative approach is to perform a functional test by

More information

Introduction to Confined Space Safety OR-OSHA

Introduction to Confined Space Safety OR-OSHA Introduction to Confined Space Safety OR-OSHA 215 0501 Trainer Name Position Company Phone Email (Revise as needed) Objectives This class provides the following information: 1. Criteria for confined spaces

More information

GasLab SAN-102 Micro Oxygen Monitor User Manual

GasLab SAN-102 Micro Oxygen Monitor User Manual GasLab SAN-102 Micro Oxygen Monitor User Manual The GasLab SAN-102 is a wearable, personal safety meter designed to monitor ambient oxygen levels in real time. It is designed to protect workers in confined

More information

RK LEL Sample Draw Aspirator Adapter Operator s Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual 30-0951RK LEL Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0017RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

Department of Physics Standard Operating Procedures (SOP) Approved by: Physics Safety Committee

Department of Physics Standard Operating Procedures (SOP) Approved by: Physics Safety Committee Page: Page 1 of 5 1 Introduction Compressed gas cylinders can present a variety of hazards due to their pressure and/or contents. One of the contributing factor to these hazards is gas leak due to malfunction

More information

STORAGE AND USE OF HIGH HAZARD GAS

STORAGE AND USE OF HIGH HAZARD GAS Page 1 of 9 STORAGE AND USE OF 1. Definition of High Hazard (HH) Gases For these guidelines, any gas meeting one or more of the following definitions based on International Fire Code (IFC) and National

More information

Ozone. Sensoric O3 3E 1

Ozone. Sensoric O3 3E 1 Ozone Sensoric O3 3E 1 1 FEATURES Amperometric 3 electrode sensor cell Long life time High reliability High resolution Fast response time Fixed organic gel electrolyte TYPICAL APPLICATIONS Environmental

More information

Aerotest Breathing Air Systems

Aerotest Breathing Air Systems DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Aerotest Breathing Air Systems Since 1937, when we introduced our first detector tube, Draeger has been the world leader in the

More information

City & County of San Francisco Office of Contract Administration Purchasing. Bid #: ITSF /CD Req #: RQUH Attachment B

City & County of San Francisco Office of Contract Administration Purchasing. Bid #: ITSF /CD Req #: RQUH Attachment B I. General Requirements A. This bid is for a four-year (48 month) lease of portable gas detection instruments, including automated instrument maintenance and program monitoring supported by the successful

More information

CYLINDER VALVE GUIDELINES TD 12/15/E

CYLINDER VALVE GUIDELINES TD 12/15/E CYLINDER VALVE GUIDELINES MIDDLE EAST GASES ASSOCIATION (MEGA) European Business Center, Office BC 25 Dubai Investments Park, PO Box: 166 Dubai-UAE Tel: +971-4-8135525 / Fax: +971-4-8135575 / E-mail: info@megases.org,

More information

Recent changes in the rules for confined space entry

Recent changes in the rules for confined space entry Recent changes in the rules for confined space entry What s in, what s out, what s new, and what s needed GfG Instrumentation, Inc. 1194 Oak Valley Drive, Suite 20, Ann Arbor, Michigan 48108 Toll free

More information

Leaders in Calibration Gas Solutions

Leaders in Calibration Gas Solutions Leaders in Calibration Gas Solutions www.cacgas.com.au Certified Analytical Calibration Gas Oil/Gas/Petrochemical CAC GAS partnered with Scientific and Technical Gases Ltd (UK) in 2007 to market precision

More information

Instrumental Technique GAS CYLINDER

Instrumental Technique GAS CYLINDER Instrumental Technique GAS CYLINDER Amitava Srimany 05-10-2013 Gas cylinder is a pressure vessel used to store gas above atmospheric pressure. Used in: Diving Mining operations Oil refineries Petrochemical

More information

SENSOR MANUAL Document No M (Revision L)

SENSOR MANUAL Document No M (Revision L) SENSOR MANUAL Document No. 7013951M (Revision L) Sensidyne, LP 00 112th Circle N, Suite 0 St. Petersburg, Florida 33716 USA (800) 451-9444 (727) 530-3602 Fax: (727) 539-0550 web: www.sensidyne.com e-mail:

More information

GasLab SAN-102 Micro Oxygen Monitor User Manual

GasLab SAN-102 Micro Oxygen Monitor User Manual GasLab SAN-102 Micro Oxygen Monitor User Manual The GasLab SAN-102 is a wearable, personal safety meter designed to monitor ambient oxygen levels in real time. It is designed to protect workers in confined

More information

Working in Gas Hazard Areas

Working in Gas Hazard Areas / Health & Safety OPERATIONS STANDARDS Ref.: Aperam Safety ST 012 Working in Gas Hazard Areas Issue: 15.05.2012 Vers.: v0 Rev.: AM Safety ST 012 v1.2 08.05.2012 Working in Gas Hazard Areas Controlled Updated

More information

Juler Group. Presents. Hydrogen Sulfide (H 2 S) Safety. Juler Group Juler Group Incorporated

Juler Group. Presents. Hydrogen Sulfide (H 2 S) Safety. Juler Group Juler Group Incorporated Juler Group Presents Hydrogen Sulfide (H 2 S) Safety JG Juler Group 2005 Juler Group Incorporated Objectives To provide summary knowledge of the hazards of working around H 2 S To provide summary knowledge

More information

(1) Is large enough and so configured that an employee can bodily enter and perform assigned work; and

(1) Is large enough and so configured that an employee can bodily enter and perform assigned work; and Confined Spaces Confined Space (1) Is large enough and so configured that an employee can bodily enter and perform assigned work; and (2) Has limited or restricted means for entry or exit (for example,

More information

Gas monitoring using GASMET FTIR

Gas monitoring using GASMET FTIR Gas monitoring using GASMET FTIR Dominic Duggan Quantitech dd@quantitech.co.uk Andrew Hobson Quantitech Antti Heikkila Gasmet Outline of the workshop: FTIR for emissions measurement Applications in ambient

More information

Specialty gases in small cylinders. Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders.

Specialty gases in small cylinders. Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders. Specialty gases in small cylinders Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders. 02 Specialty gases in small cylinders Our specialty gases guarantee precision.

More information

1. Class "A" - an environment that is immediately dangerous to life of health. (Entry by permit only shall have a posted sign.)

1. Class A - an environment that is immediately dangerous to life of health. (Entry by permit only shall have a posted sign.) City & County of Broomfield Operational Procedures for Confined Space Entry I. Purpose: To provide an outline of operations, procedures, responsibilities, and minimum safety requirements to be followed

More information

Spot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements

Spot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements Spot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements Why is Gas Detection Important? Spot the hazard Composition of Fresh

More information

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司 X-Flow Mass Flow Controller 2 Highlights Parker Hannifin Precision Fluidics Division is excited to introduce X-Flow, a new easy to use general purpose mass flow controller for your instrument, lab, or

More information

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane Gas requirements Gases for packed columns The carrier gas you use depends upon the type of detector and the performance requirements. Table 520-1 lists gas recommendations for packed column use. In general,

More information

Discovery HP-TGA 75/750. Site Preparation Guide

Discovery HP-TGA 75/750. Site Preparation Guide Discovery HP-TGA 75/750 Site Preparation Guide Revision A Issued August 2018 Table of Contents Table of Contents... 2 Ideal Setup... 3 System Components... 4 Instrument Measurements... 5 Utility Requirements...

More information

Vehicle and Engine Emissions Testing

Vehicle and Engine Emissions Testing Vehicle and Engine Emissions Testing Calibration gases and equipment for compliance Benefits and Features Guaranteed analytical accuracy facilitates precise instrument calibration to ensure Part 1065,

More information

800.Keen.Gas

800.Keen.Gas C 2 H 2 ACETYLENE Acetylene is a colorless and tasteless gas with a garlic-like odor. It is flammable and can be an asphyxiant. In order to prevent explosive decomposition, acetylene is supplied in cylinders

More information

CALIBRATION KIT. Instruction Manual

CALIBRATION KIT. Instruction Manual CALIBRATION KIT Instruction Manual 2 CALIBRATION KIT CALIBRATION KIT 3 Table of Contents General description....4 Getting Started....4 GG-NH3....5 GG-NH3-2%....6 GG-CO....7 GG-CO2...8 GG-CL2...9 GG-H2-EC....

More information

Technical Data for Alicat M-Series Mass Flow Meters sccm Full Scale through slpm Full Scale

Technical Data for Alicat M-Series Mass Flow Meters sccm Full Scale through slpm Full Scale Technical Data for Alicat s 0 0.5 sccm Full Scale through 0 4000 slpm Full Scale Standard Specifications (Contact Alicat for available options.) Performance Accuracy at calibration conditions after tare

More information

Compressed Gas ER Fundamentals

Compressed Gas ER Fundamentals Compressed Gas ER Fundamentals Jan 2015 Compressed Gases Represent over 66% of RMP Chemicals PHMSA's 2012 Emergency Response Guidebook provides first responders with a go-to manual to help deal with hazmat

More information

Technical Data for Alicat MC and MCR Mass Flow Controllers sccm Full Scale through slpm Full Scale

Technical Data for Alicat MC and MCR Mass Flow Controllers sccm Full Scale through slpm Full Scale Technical Data for Alicat MC and MCR Mass Flow Controllers 0 0.5 sccm Full Scale through 0 3000 slpm Full Scale Standard Specifications (Contact Alicat for available options.) Performance Accuracy at calibration

More information

Quebec Quebec Tel : Fax : MSDS: Hydrogen Sulfide in Nitrogen Mixture PRODUCT INFORMATION

Quebec Quebec Tel : Fax : MSDS: Hydrogen Sulfide in Nitrogen Mixture PRODUCT INFORMATION Tel: 514-956-7503 Fax: 514-956-7504 Internet: www.megs.ca Email : support@megs.ca Montreal Ottawa St-Laurent Nepean Tel : 514-956-7503 Tel : 613-226-4228 Fax : 514-956-7504 Fax : 613-226-4229 Quebec Quebec

More information

Multiple Tube - Teflon PTFE-Glass Flowmeters

Multiple Tube - Teflon PTFE-Glass Flowmeters Multiple Tube - Teflon PTFE-Glass Flowmeters xt Model xt Multiple Tube Teflon PTFE-Glass Flowmeters combine the convenience of multiple tube meters with the unique design features of single tube Teflon

More information

Guide to Gases and Vapours

Guide to Gases and Vapours Guide to Gases and Vapours Properties of dangerous Gases and Vapours Flammable and toxic gases and vapours may occur in many places. To deal with the toxic risk and the danger of explosion this is what

More information

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results. Laboratory Hardware Custom Gas Chromatography Solutions Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions

More information

Flammability Chart. Gas Formula Ignition

Flammability Chart. Gas Formula Ignition Leak Detection 101 Investigating a leak is simplified if you know the basics. By J. Scott Kleppe Sensit (J and N Enterprises, Inc.) Every day new gas services are added to provide economical energy to

More information

Aerotest Breathing Air Systems

Aerotest Breathing Air Systems DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Aerotest Breathing Air Systems Since 1937, when we introduced our first detector tube, Draeger has been the world leader in the

More information

Single Tube Flowmeters

Single Tube Flowmeters Single Tube Flowmeters P Interchangeable Designed for low flowrates, the model P flowmeter is a precision instrument embodying the inherent simplicity, versatility and economy of the classical variable

More information

8.1 Calibration of gas sensors

8.1 Calibration of gas sensors 8.1 Calibration of gas sensors! CAUTION! Calibration gas handling and precautions Observe safety regulation and accident prevention regulations when using or handling test gases. Use test gases in well-ventilated

More information

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs. Laboratory Hardware Custom Gas Chromatography Solutions Custom solutions for your analytical needs. Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions for advanced chromatography

More information

BASF Corporation Title: Portable Multi-Gas Monitoring Equipment. Individual Unit Function: Safety Procedure No.: GSS09 Page: 1 of 5

BASF Corporation Title: Portable Multi-Gas Monitoring Equipment. Individual Unit Function: Safety Procedure No.: GSS09 Page: 1 of 5 Procedure No.: GSS09 Page: 1 of 5 RECORD OF REVISIONS Date Details of Change Sept. 01 The revision addresses the deletion of the tool room responsibilities and defines the new responsibilities for the

More information

Continuous gas analysis ULTRAMAT 23 Supplement 2 for Operating Instructions C79000-G52xx- C216-03

Continuous gas analysis ULTRAMAT 23 Supplement 2 for Operating Instructions C79000-G52xx- C216-03 Continuous gas analysis ULTRAMAT 23 Supplement 2 for Operating Instructions C79000-G52xx- C216-03 Product Information Legal information Warning notice system This manual contains notices you have to observe

More information

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Oxygen Measurement Systems High Reliability and Wide Application Coverage Introduction High Process Efficiency Under Any Condition Oxygen Measurement Systems High Reliability and Wide Application Coverage METTLER TOLEDO provides sensors to measure dissolved oxygen (DO) in demanding

More information

There is no protection without detection. HiQ specialty gases, equipment and services for environmental monitoring.

There is no protection without detection. HiQ specialty gases, equipment and services for environmental monitoring. There is no protection without detection. HiQ specialty gases, equipment and services for environmental monitoring. 02 HiQ specialty gases, equipment and services for environmental monitoring. HiQ pure

More information

There is no protection without detection. HiQ Specialty Gases, Equipment and Services for Environmental Monitoring.

There is no protection without detection. HiQ Specialty Gases, Equipment and Services for Environmental Monitoring. There is no protection without detection. HiQ Specialty Gases, Equipment and Services for Environmental Monitoring. 02 HiQ Specialty Gases, Equipment and Services for Environmental Monitoring HiQ Specialty

More information

Typical Single Stage Design SR 450 Series Shown. Two stage regulators add the following in addition to the features listed above:

Typical Single Stage Design SR 450 Series Shown. Two stage regulators add the following in addition to the features listed above: Single Stage : Recommended for applications where slight delivery pressure increases (due to decreasing cylinder pressures) would not affect the performance characteristics of the work or test results.

More information

WHAT IS GAS TANK/CYLINDER?

WHAT IS GAS TANK/CYLINDER? Introduction To use compressed gas cylinders safely, it is important that they are stored properly, handled correctly, used with the correct equipment, and that the properties of the gases they contain

More information

Identifying Confined Space. By Jeff Lavery KC Supply Co

Identifying Confined Space. By Jeff Lavery KC Supply Co Identifying Confined Space By Jeff Lavery KC Supply Co Overview Confined Space Entry Permit Required Grain Bin Entry Hazards Examples Summary Grain Industry 1910.146 Confined Space Special Hazard Industry

More information

Operation and Maintenance Manual

Operation and Maintenance Manual Operation and Maintenance Manual GDS-50 Remote Infrared Sensor Transmitter for Combustibles & CO 2 AUTHORIZED DISTRIBUTOR: GasDetectorsUSA.com - Houston, Texas USA sales@gasdetectorsusa.com - 832-615-3588

More information

Chapter 4: Monitoring and Sampling. Chapter 4: Monitoring and Sampling

Chapter 4: Monitoring and Sampling. Chapter 4: Monitoring and Sampling Chapter 4: Monitoring and Sampling Monitoring, or sampling, is necessary to determine the identity or type of a substance and the amount of a substance. This information may be used to determine if workers

More information

CONFINED SPACE PROGRAM

CONFINED SPACE PROGRAM CONFINED SPACE PROGRAM I. Purpose This Confined Space Program has been developed in accordance with the Occupational Safety and Health Administration (OSHA) regulations 29 CFR 1910.146. The purpose of

More information

USER'S MANUAL HOT-WIRE TYPE GAS SENSOR NAP-100A SERIES ( NET10A(R) ) (For All Combustible Gases)

USER'S MANUAL HOT-WIRE TYPE GAS SENSOR NAP-100A SERIES ( NET10A(R) ) (For All Combustible Gases) (June 27, 2002) USER'S MANUAL HOT-WIRE TYPE GAS SENSOR NAP-100A SERIES ( NET10A(R) ) (For All Combustible Gases) 1. General Being designed for light industrial applications, NAP-100A series also available

More information

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology: Title: Comparison of Chemical Sensor and NDIR Technologies TSN Number: 25 File:\\MII- SRV1\Metron\Bridge_Analyzers\Customer_Service_Documentation\White_Papers\25_G en EGA NDIR vs Chemical Sensor.docx Created

More information

Multiple Tube Flowmeters

Multiple Tube Flowmeters Multiple Tube Flowmeters xp The model xp multiple tube flowmeter line offers, the convenience and simplicity of 2, 3, 4, 5 and 6 tube meters, retaining most of the unique design features associated with

More information

HiQ laboratory gas generators.

HiQ laboratory gas generators. Product information HiQ laboratory gas generators. The convenient alternative for laboratory environments. 02 HiQ laboratory gas generators HiQ laboratory gas generators. Designed with safety and convenience

More information

3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems. Work. in a World of.

3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems. Work. in a World of. 3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems Work in a World of Comfort 3M TM Versaflo TM AP-600 Series Air Filtration Panels (AFP)

More information

Use of Hazardous Gases Standard Operating Procedure

Use of Hazardous Gases Standard Operating Procedure Use of Hazardous Gases Standard Operating Procedure 1. Purpose This standard operating procedure (SOP) details the requirements for ordering, storing, using, and disposing of toxic, highly toxic, pyrophoric,

More information

NEW Edge Series Products: OUTFITS and REGULATORS

NEW Edge Series Products: OUTFITS and REGULATORS NEW Edge Series Products: OUTFITS and REGULATORS NOW Including ESS3 Models and More Edge Series Outfits User Friendly Advanced Design Outstanding Flow Performance Unsurpassed Safety www.victoredge.com

More information

The lighter range. Alumini mini-containers from Westfalen.

The lighter range. Alumini mini-containers from Westfalen. The lighter range. Alumini mini-containers from Westfalen. Alumini. Our mini-containers for your flexibility. Solutions for all applications Even here at Westfalen we're constantly amazed at the sheer

More information

Technical Data for Alicat MS Series Mass Flow Meters

Technical Data for Alicat MS Series Mass Flow Meters Technical Data for Alicat MS Series Mass Flow Meters Alicat MS instruments are built for use with aggressive For the most part, these instruments maintain the specifications of equivalently ranged M Series

More information

c) Loss of product or replacement when units are being serviced All of these are factors that need to be considered by the user.

c) Loss of product or replacement when units are being serviced All of these are factors that need to be considered by the user. GAS DETECTION Cost of Ownership In today's competitive marketplace the initial cost of any capital equipment is important to the end user but of equal importance is the ongoing cost of ownership. In many

More information

2018 National Metal and Nonmetal Mine Rescue Contest. Technician Team Competition Written Test (Dräger BG-4) Good Luck!

2018 National Metal and Nonmetal Mine Rescue Contest. Technician Team Competition Written Test (Dräger BG-4) Good Luck! 2018 National Metal and Nonmetal Mine Rescue Contest Technician Team Competition Written Test (Dräger BG-4) Directions: 1. Find the correct answer to each of the questions. 2. Select only one answer per

More information

Operating Instructions

Operating Instructions Operating Instructions Sensors Type 705 H 2 S Sensor and Transmitter for Electrochemical Cells Ul Certified HELPING TO MAKE A SAFER WORLD Ensure that you read and understand these operating instructions

More information

Contaminated Air in Cylinders By Ronny J. Coleman

Contaminated Air in Cylinders By Ronny J. Coleman Contaminated Air in Cylinders By Ronny J. Coleman Introduction How many people today know what the term black damp means? I learned the term at a very young age that black damp could be deadly when you

More information

Confined Space Entry Program 8 CCR 5157

Confined Space Entry Program 8 CCR 5157 TABLE OF CONTENTS 1. POLICY... 2 2. PURPOSE... 2 3. SCOPE... 2 4. DEFINITIONS... 2 5. CONFINED SPACES IN THE SACRAMENTO STATE... 4 6. PERMIT SPACE ENTRY - PERSONNEL RESPONSIBILITIES... 4 6.1. CONFINED

More information

A BRIEF TUTORIAL ON GAS HANDLING EQUIPMENT

A BRIEF TUTORIAL ON GAS HANDLING EQUIPMENT TABLE OF CONTENTS BACK PRESSURE REGULATORS...26 CGA CONNECTION DRAWINGS...102 CGA CYLINDER CONNECTIONS AND GASKETS...98 CHANGEOVER MANIFOLDS...60-63,65 CHECK VALVES...70 CONVERSION TABLES...103 CUSTOM

More information

Specification & scope of work for Multi Component Gas Separation test Rig

Specification & scope of work for Multi Component Gas Separation test Rig XUR Specification & scope of work for ulti Component Gas Separation test Rig 1. Design, supply, assembly and commissioning of the ulti-component gas separation Test rig as per the schematic layout given

More information