MANIFLEX System. 52B Series 52C Series 52S Series INSTALLATION AND OPERATION INSTRUCTIONS
|
|
- Amie Hudson
- 5 years ago
- Views:
Transcription
1 ADI 3213C Certified ISO 9001 MANIFLEX System 52B Series 52C Series 52S Series INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation of America 1501 Harpers Road Virginia Beach, VA To Order Call or Fax March 2018
2 DESCRIPTION OF PRODUCT The 52B (brass), 52C (chrome plated brass), and 52S (stainless steel) Series Maniflex Systems are modular gas distribution systems that may be connected to regulators, dual regulator switchovers, CONCOA AutoSwitch systems, CONCOA IntelliSwitch systems, or any other system with a ½ NPT female or a ¼ NPT female inlet port. A modular gas distribution system allows the user to size the inlet capacity of a system so that cylinder changes will not be as frequent. The Maniflex System provides the user with the capability of purchasing an unlimited number of manifold stations connected to a single header, and models are available with either standard 12 (305mm) cylinder station spacing or compact 6 (152mm) cylinder station spacing. Figure 1. Maniflex Starter Block with One Extension 1/4 NPT Female Port 3 3/16 (81.0mm) 1.35 (34mm) STANDARD MODELS 12 (305mm) 3 (76mm) Station Spacing ø7/16 (ø11mm) Hole Typ. Starter Block 12 Extension Kit: # = Brass # = Chrome Plated # = Stainless Steel Move Plug Assembly (Comes with Starter Block) to End of Manifold. COMPACT MODELS 6 (152mm) Station Spacing 6 Extension Kit: # = Brass # = Chrome Plated # = Stainless Steel USER RESPONSIBILITY This equipment will perform in conformity with the description contained in this manual and accompanying labels and/or inserts when installed, operated, maintained, and repaired in accordance with the instructions provided. This equipment must be checked periodically for leaks and functionality. Equipment that is not working properly should not be used. Parts that are broken, missing, worn, or distorted should be replaced immediately. CONCOA recommends that a telephone or written request for service advice be made to CONCOA Customer Service in Virginia Beach, Virginia, PHONE: , FAX: , or @concoa.com. This equipment or any of its parts should not be altered without prior written approval by CONCOA. The user of this equipment shall have the sole responsibility for any malfunction that results from improper use, faulty maintenance, damage, improper repair, or alteration by anyone other than CONCOA or a service facility designated by CONCOA. -2-
3 CUSTOMER ASSISTANCE In the event of equipment failure, call the CONCOA Customer Assistance Line: Please be prepared to provide the model number and serial number of the equipment involved, in addition to some details regarding its application. This would include inlet and outlet pressures, flow rate, environmental conditions, and gas service. Things to consider before removing the system from the box: 1. Know the properties and special handling requirements of the gas being used. Many specialty gases are quite dangerous (flammable, toxic, corrosive, simple asphyxiant, or oxidizers). Equipment failure or misuse may lead to the sudden release of service gas into the surrounding area. Proper safety measures should be established to handle these and other component failures. 2. Be sure that the assembly purchased is suitable for the gas and type of service intended. The label provides the following information: a. Model Number b. Serial number 3. Be sure that the equipment received conforms to the order specifications. The user is responsible for selecting equipment compatible with the gas in use, and conditions of pressure, temperature, flow, etc. 4. Selection information can be found in CONCOA technical data sheets. In addition, CONCOA representatives are trained to aid in the selection Process. 5. Inspect the assembly upon receipt to be sure that there is no damage or contamination. Pay particular attention to connecting threads. While CONCOA assembles system components to exacting leak-tight standards, the customer should also inspect for any loosening of parts that may occur in shipping or installation. Loose parts may be dangerously propelled from an assembly. If there are adverse signs (leakage or other malfunction), return the assembly to the supplier. While it is advised that soiled components be returned for cleaning, simple external dust or grease may be removed by a clean cloth and if required with aqueous detergent suitable for the application. If there are signs of internal contamination, return to the supplier. GENERAL SAFETY PRACTICES 1. Before system startup, it is recommended that all systems be pressure tested, leak tested, and purged with an inert gas such as nitrogen. To accomplish this with connections other than a CGA 580, it will be necessary to use an adapter. The recommended use of an adapter is for temporary use, for start-up and system checks only. Adapters should never be used on a permanent basis. 2. Comply with precautions listed in C.G.A. Pamphlet P-1, Safe Handling of Compressed Gases in containers. 3. Consult the cylinder distributor for the proper use of cylinders and for any restrictions on their use(such as flow rate and temperature requirements). 4. Store cylinders with valve caps screwed on, and cylinders chained to a supporting wall or column.handle cylinders carefully and only with valve caps screwed on. The cap will reduce the chance that the cylinder valve will break off if the cylinder is accidentally dropped or falls over. The cap also protects the cylinder valve from damage to screw threads, which could cause leaky connections. 5. All manifolds used with flammable gases should be provided with approved flashback arrestors to stop any burning gas in the pipeline from getting back to the manifold or cylinders. 6. No smoking should be permitted near oxygen, nitrous oxide, any other oxidizer, flammable gases, or flammable mixtures, or in areas where cylinders are stored.. -3-
4 7. Where oxygen or nitrous oxide is used, the manifold and cylinders must be kept clean. No oil, grease, or combustible substances should come in contact with oxygen or nitrous oxide storage or handling equipment. Such materials in contact with oxygen or nitrous oxide are readily ignitable and when ignited, will burn intensely. 8. Never use an open flame when leak testing. 9. Always open valves slowly when high-pressure gases are being used. 10. Always be sure that a cylinder contains the correct gas before connecting it to any manifold. 11. Always leak-test any manifold or distribution pipeline before using. 12. Always be sure that the gas in a pipeline is the correct gas for the intended use. 13. Always close all cylinder valves before disconnecting cylinders from a manifold. 14. Always remove all empty cylinders from a manifold before connecting full cylinders. 15. Always test cylinders to be sure the cylinders are full before connecting to a manifold. All gas distribution piping systems must meet the appropriate industrial standards for the intended service and must be thoroughly cleaned before using. For the United States, some applicable safety rules and precautions are listed below: 1. American National Standards Institute standard Z49.1 or Safety in Welding and Cutting, American Welding Society, 2501 NW Seventh Street, Miami, FL N.F.P.A. Standard 51, Oxygen-Fuel Gas Systems for Welding and Cutting, N.F.P.A., 470 Atlantic Avenue, Boston, MA N.F.P.A. Standard 51B, Cutting and Welding Processes, (see Address in #2) 4. N.F.P.A. Standard 55, Compressed Gases and Cryogenic Fluids Code 5. CONCOA Publication ADE 872, Safety Precautions in Welding and Cutting. 6. Local ordinances. 7. O.S.H.A. Standard 29 CFR. 8. C.G.A. Pamphlet C-4, American National Standard Method of Marking Portable Compressed Gas Containers to Identify the Material Contained.* 9. C.G.A. Pamphlet G-4, Oxygen-Information on the properties, manufacture, transportation, storage, handling, and use of oxygen. 10. C.G.A. Pamphlet G-4.1, Equipment Cleaned for Oxygen Service. 11. C.G.A. Pamphlet C-4.4, Industrial Practices for Gaseous Oxygen Transmission and Distribution Piping Systems. 12. C.G.A. Pamphlet G-5, Hydrogen - Information on the properties, manufacture, transportation, storage, handling, and use of hydrogen. 13. C.G.A. Pamphlet G-6, Carbon Dioxide - Information on the properties, manufacture, transportation, storage, handling, and use of carbon dioxide. 14. C.G.A. Pamphlet G-6.1, Standard for Low Pressure Carbon Dioxide Systems at Consumer Sites. 15. C.C.A. Pamphlet P-1, safe handling of compressed gases in containers. 16. C.G.A. Safety Bulletin SB-2, Oxygen Deficient Atmospheres. *C.G.A. pamphlets can be obtained from the Compressed Gas Association: 1235 Jefferson Davis Highway, Arlington, VA , (703) Publications: (703) Fax: (703)
5 MANIFOLD LOCATION Keep all cylinders and manifolds away from any source of high temperature over 120 F (50 C) or possible fire hazards. High-pressure gas contained in a closed cylinder becomes increasingly dangerous when exposed to high temperature because pressure increases and the strength of the cylinder decreases. Manifolds installed in open locations should be protected from weather conditions. During winter, protect the manifold from ice and snow. In summer, shade the manifold and cylinders from continuous exposure to direct sunlight. Always leave access to the manifold for cylinder replacement. The site chosen for them manifold installation shall be level, well ventilated, and at a safe distance from the sources of flames, sparks, and excessive heat. The manifold should not be placed in an area that may subject the manifold to damage from passing trucks, cranes, or other heavy machines. Oxygen manifolds must not be installed under shafting, belting, or other places where oil can drip on them. For other location guidelines, see NFPA Standard 51. INSTALLATION CONSIDERATIONS 1. Be sure to consider all factors when selecting materials. 2. Do not use oil or grease on fittings. 3. Make sure that all fittings are secure and leak tight. PTFE tape should be used on pipe threads. 4. Purge devices: These devices can be purchased as accessories. Purge devices are used to remove toxic, corrosive, or flammable gases from the customer s system to a safe discharge area. This is particularly helpful when an internal problem occurs such as a regulator malfunction. INSTALLING PIPE THREAD CONNECTIONS Use an open-end wrench, not a pipe wrench, to install accessories to the system. The NPT connections require the use of PTFE tape on the threads to make a gas tight seal. On stainless steel connections, the PTFE tape also helps to prevent the connections from galling together when tightening or loosening. Follow the rules below when using PTFE tape: Figure 2. Taping Procedure Diagram -5-
6 Taping procedure: Before applying PTFE tape, inspect the NPT threads, and if necessary, clean the fitting to remove any dirt or thread sealant that remains on the threads. Start the PTFE tape on the first thread leaving a slight section of the chamfer exposed as shown in the Taping Procedure Diagram. Make sure the tape does not overlap the end of the fitting. As the tape is wrapped in the direction of the thread spiral, pull tightly on the end of the tape so that the tape conforms to the threads. Apply at least 2 but no more than 3 layers of tape to the threads. Cut off excess tape, and press the end firmly into the threads. INSTALLATION INSTRUCTIONS SINGLE ROW MANIFOLDS The Maniflex System is normally installed on a wall with 1 gas cylinder per cylinder station. This arrangement is referred to as Single Row. CONCOA has available a variety of manifold connectors to use for connecting your C2 Series Maniflex system to another system. These connectors are shown in the figure below: *S =.393 (10mm) # /2 x 1/4 NPT Manifold Connector (Stainless Steel) 1/2 NPT Male (186mm) 1/4 NPT Male *S =.267 (6.8mm) # /4 x 1/4 NPT Manifold Connector (Stainless Steel) (183mm) 1/4 NPT Male 1/4 NPT Male *S = Nominal Depth of Sink Into Female Port ±2 Threads (±0.11 [3mm] for 1/4 NPT Threads, ±0.143 [4mm] for 1/2 NPT Threads) *S =.267 (6.8mm) Typ. Into Starter Block # /2 x 1/4 NPT Mini Manifold Connector (Stainless Steel) *S =.393 (10mm) 1/2 NPT Male 1/4 NPT Male (53.8mm) # /4 x 1/4 NPT Mini Manifold Connector (Stainless Steel) *S =.267 (6.8mm) 1/4 NPT Male 1/4 NPT Male (51.5mm) Figure 3. Manifold Connectors 1. Refer to the CONCOA instruction manual for mounting instructions for the system to which you are connecting the Maniflex system. 2. A typical installation for high-pressure cylinders will require the center-line of the system inlet to be at least 66 (1676mm) above the floor. 3. Customer is to provide and use appropriate fasteners for attaching the system to the wall or floor. 4. The manifold connector (see Figure 3) can be disassembled for ease of installation. 5. Wrap the male NPT threads of the manifold connector with PTFE tape according to the instructions in the Installing Pipe Thread Connections section above. -6-
7 6. For systems that have a bulkhead fitting (i.e., the CONCOA AutoSwitch and IntelliSwitch systems), ALWAYS hold the bulkhead fitting with a wrench when installing accessories. Do not allow the bulkhead fitting to turn; otherwise, connections inside the system enclosure may be loosened. 7. Assemble the taped manifold connector fittings into the Maniflex starter block port and into the system inlet port as appropriate. 8. Assemble the mounting bracket to the starter block (see Figure 5). 9. Connect the starter block/manifold connector assembly to the system, and tighten the compression fittings. 10. Ensure that the starter block is level, and mark the wall at the mounting bracket hole. Figure 4. Level Starter Block 11. Secure the starter block assembly to the wall using appropriate fasteners. 12. The starter block will include an end plug assembly. This is to be used on the final block of your Maniflex System. 12. Assemble mounting brackets to the remaining extension blocks. 13. Loosely assemble each extension tube one at a time to each extension block. DO NOT USE PTFE TAPE. 14. One at a time, level and install each extension assembly. Tighten the compression fittings on both sides of the block before securing the extension block to the wall with appropriate fasteners. 15. Before installing an extension block assembly, ensure that preceding compression fittings have been tightened. 16. With all extensions completely installed, tighten the end plug to the open end of the final extension block. 17. Ensure that all connections are tightened. 19. Remove the pipe plug from the bottom port of each Maniflex station block. 20. Wrap the male NPT thread of each flexible hose with PTFE tape according to the instructions in the Installing Pipe Thread Connections section above. 21. Install each pigtail into the bottom port of each Maniflex station. 22. Refer to Connecting to a Cylinder instructions below for connecting the pigtail(s) to the cylinder(s). Starter Block Manifold Connector Mounting Bracket with Fasteners, Typ. Each Block 1/4-20 Screw, Typ. ø7/16 (ø11mm) Hole, Typ. 1/4 NPT Connection to Starter Block Remove Each 1/4 NPT Bottom Plug for Installation of Flexible Hoses. Extension Block with Extension Tube, Typical All Blocks After Starter Block CGA 680 Connection, Typ. Figure 5. Exploded Assembly Detail End Plug Assembly (Comes with Starter Block) -7-
8 INSTALLATION INSTRUCTIONS DOUBLE ROW MANIFOLDS Maniflex Systems can also be installed for use with 2 gas cylinders per cylinder station. This arrangement is referred to as Double Row. For floor mounted systems, the customer must provide the means for mounting the system to the floor. Remove 1/4 NPT Plugs from Both Sides of Each Station Block for Installation of Flexible Hoses. 1/4 NPT Connection to Starter Block CGA 680 Connection, Typ. Extension Block with Extension Tube, Typical All Blocks After Starter Block Manifold Connector FLOOR MOUNT ARRANGEMENT (Customer Provides Floor Mounting Hardware) Starter Block Mounting Bracket with Fasteners, Typ. Each Block 1/4-20 Screw, Typ. End Plug Assembly (Comes with Starter Block) For Wall Mount Double Row Arrangements, Install an Elbow (Included with System) Into the Top 1/4 NPT Port of Each Station Block. INSTALL INSTALL WALL MOUNT ARRANGEMENT Figure 6. Double Row Installation CONNECTING TO A CYLINDER 1. Read the next section before installing the cylinders. 2. Before removing the cylinder cap, move the cylinder of gas to the work site: a. Secure cylinder to the floor, wall, stand, or bench with appropriate chain, strap, or stand to prevent toppling (CONCOA part number , cylinder wall bracket is appropriate). b. Remove the cylinder cap. c. Be sure the cylinder valve is tightly closed (clockwise) d. Remove the cylinder valve plug, if any. e. Inspect the cylinder valve and threads for damage or contamination. 3. Secure the cylinder connection to the cylinder in the following manner: a. Thread the nut onto the cylinder connection; it should fit easily. Do not force. If it does not fit, the connection may be wrong for the type of gas being used. b. Left-hand threads are used on some cylinder connections. A notch in the middle of the hex nut typically indicates a left-hand thread. c. Gaskets are used on some inlet connections. Be sure the gasket is in good shape. Do not overtighten to avoid squashing the gasket into the gas line. Keep extra gaskets on hand. -8-
9 WARNING: Never use oil or grease on regulator or cylinder fittings, as it may contaminate pure gases, or create a fire hazard. Before system startup, it is recommended that all systems be pressure tested, leak tested, and purged with an inert gas such as nitrogen. To accomplish this with connections other than a CGA 580, it will be necessary to use an adapter. The recommended use of an adapter is for temporary use only, for system start up and checks. Adapters should never be used on a permanent basis.\ 1. Wear safety glasses and gloves. 2. Connect a nitrogen cylinder to the last pigtail on the manifold. Connect the appropriate gas cylinders to the remaining pigtails. Do not open the cylinder valves yet. 3. Be sure that both ends of all hoses or pigtails are secured before pressurizing. Turn off (clockwise) all manifold header valves with the exception of the header valve for the nitrogen cylinder. Turn the line regulator knob or adjustable regulator knob counterclockwise until the knob stops turning. 4. When first pressurizing, do not stand in front of or contact any regulator or switchover systems. Slowly open the nitrogen cylinder valve. Observe the high pressure gauge or readout on the system to which the Maniflex is connected, and check for a rise in pressure up to full cylinder pressure. WARNING: If the attached regulator is preset or the system is a dual regulator switchover without the optional line regulator, gas will escape from the delivery side of the regulator. 5. Keep the hand wheel or wrench on the open cylinder valve at all times to allow prompt emergency shut-off. 6. One at a time, open the other manifold header valves (slowly) to pressurize the pigtails (not the cylinder valves). 7. Inspect all connections for leaks and fix any leaks. A leak detection solution may be applied to the connections (if compatible with the application) that indicates leaks by bubbling. To further check for leaks, or if the leak detection solution cannot be used, close the cylinder valve(s) for a period of time (recommended 24 hours), and observe the high pressure gauge for a drop in pressure. If so indicated, recheck the cylinder connection and all other high-pressure port connections. Never attempt to fix a leak under pressure. If leaks are detected, depressurize the system and retighten the connection. Begin again at step Turn the regulator knob or line regulator knob clockwise to increase the pressure on the delivery side of the system. 9. Check the delivery side for leaks as described in the steps above. 10. When all leaks are fixed, turn off the nitrogen cylinder valve and manifold header valve. Disconnect the nitrogen cylinder and remove the adapter. Connect service gas cylinders to the manifold. OPERATION Follow the instructions supplied with the regulator, dual regulator switchover, AutoSwitch, IntelliSwitch, or other system when operating these devices. When removing a cylinder from the manifold, the manifold header valve must be closed first. MAINTENANCE At regular intervals, the Maniflex system should be checked for leaks and proper function (see trouble shooting). The pigtail check valve should also be checked for leaks when a depleted cylinder is removed. Note: the system inlet and pigtail should be pressurized when checking for leaks. Any leaks in the system should be corrected immediately. -9-
10 TROUBLESHOOTING Typical symptoms listed below indicate Maniflex system malfunctions needing repair. Replace immediately with a clean, repaired and tested, or new system. 1. Gas leakage from any joint. 2. Manifold header valve when closed does not cut off the gas supply to the regulator, dual regulator switchover, or AutoSwitch. 3. The system makes a noise or hums. SERVICE A unit that is not functioning properly should not be used. It is recommended that all servicing be done by a service facility authorized by CONCOA. Prior to returning equipment to CONCOA for warranty or non-warranty repair, contact Customer Service in Virginia Beach, Virginia. If so advised, the unit should be sent to a service facility authorized by CONCOA. Do the following before shipping: 1. Adequately package the system. If possible package in the original shipping container. 2. Ship prepaid. 3. Include a statement of the observed deficiency. 4. Indicate the gas service that the equipment was used on. 5. Purge all equipment before shipment to protect the transporter and service personnel. The purging is particularly important if the equipment has been in hazardous or corrosive gas service. Return trip transportation charges are to be paid by the Buyer. In all cases where the warranty has expired, repairs will be made at current list price for the replacement part(s), plus a reasonable labor charge. -10-
11 Warranty Information This equipment is sold by CONTROLS CORPORATION OF AMERICA under the warranties set forth in the following paragraphs. Such warranties are extended only with respect to the purchase of this equipment directly from CONTROLS CORPORATION OF AMERICA or its Authorized Distributors as new merchandise and are extended to the first Buyer thereof other than for the purpose of resale. For a period of one (1) year from the date of original delivery (90 days in corrosive service) to Buyer or to Buyer s order, this equipment is warrantied to be free from functional defects in materials and workmanship and to conform to the description of this equipment contained in this manual and any accompanying labels and/or inserts, provided that the same is properly operated under conditions of normal use and that regular periodic maintenance and service is performed or replacements made in accordance with the instructions provided. The foregoing warranties shall not apply if the equipment has been repaired: other than by CONTROLS CORPORATION OF AMERICA or a designated service facility or in accordance with written instructions provided by CONTROLS CORPORATION OF AMERICA, or altered by anyone other than CONTROLS CORPORATION OF AMERICA, or if the equipment has been subject to abuse, misuse, negligence or accident. CONTROLS CORPORATION OF AMERICA s sole and exclusive obligation and Buyer s sole and exclusive remedy under the above warranties is limited to repairing or replacing, free of charge, at CONTROLS CORPORATION OF AMERICA s option, the equipment or part, which is reported to its Authorized Distributor from whom purchased, and which if so advised, is returned with a statement of the observed deficiency, and proof of purchase of equipment or part not later than seven (7) days after the expiration date of the applicable warranty, to the nearest designated service facility during normal business hours, transportation charges prepaid, and which upon examination, is found not to comply with the above warranties. Return trip transportation charges for the equipment or part shall be paid by Buyer. CONTROLS CORPORATION OF AMERICA SHALL NOT BE OTHERWISE LIABLE FOR ANY DAMAGES INCLUDING BUT NOT LIMITED TO: INCIDENTAL DAMAGES, CONSEQUENTIAL DAMAGES, OR SPECIAL DAMAGES, WHETHER SUCH DAMAGES RESULT FROM NEGLIGENCE, BREACH OF WARRANTY OR OTHERWISE. THERE ARE NO EXPRESS OR IMPLIED WARRANTIES WHICH EXTEND BEYOND THE WARRANTIES HEREINABOVE SET FORTH. CONTROLS CORPORATION OF AMERICA MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE EQUIPMENT OR PARTS THEREOF. -11-
12 ADI 3213C Certified ISO 9001 Controls Corporation of America 1501 Harpers Road Virginia Beach, VA To Order Call or Fax
Protocol Switchover Station
ADI 3215-B Certified ISO 9001 Protocol Switchover Station INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation of America
More information453 Series Steam Heated Vaporizing Regulator
ADI 0453A Certified ISO 9001:2000 453 Series Steam Heated Vaporizing Regulator INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation
More information623 Series Dome Load Regulators
ADI 3202C Certified ISO 9001 623 Series Dome Load Regulators INSTALLATION AND OPERATION INSTRUCTIONS This Equipment is intended to be installed and operated by trained personnel. Before Installing or Operating,
More informationThe 527 Series Automatic Switchover System
ADI 3167-F Certified ISO 9001:2000 The 527 Series Automatic Switchover System For use with Ultra High Purity Gases INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply
More information624 Gas Panels INSTALLATION AND OPERATION INSTRUCTIONS. Before Installing or Operating, Read and Comply with These Instructions
ADI 3203-A Certified ISO 9001 624 Gas Panels Warning: An appropriately sized pressure relief device downstream of the regulator should be installed in your system to prevent damage to equipment and/or
More informationSINGLE STAGE ULTRA-HIGH PRESSURE REDUCING REGULATOR INSTALLATION AND OPERATION INSTRUCTIONS. Certified ISO 9001
SINGLE STAGE ULTRA-HIGH PRESSURE REDUCING REGULATOR INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Warning: An appropriately sized pressure
More information601 Series Regulators
ADI 3218A Certified ISO 9001 601 Series Regulators INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation of America 1501 Harpers
More informationThe 527 Series Automatic Switchover System with Inlet Pressure Transducers
ADI 0527-B Certified ISO 9001 The 527 Series Automatic Switchover System with Inlet Pressure Transducers For use with Ultra High Purity Gases INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or
More information629 Series MicroManifold & Vent Kit System
ADI3221-A Certified ISO 91:2 629 Series MicroManifold & Vent Kit System INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation
More informationHigh Pressure Inlet Kits for CONCOA BlendMites and BlendMasters
ADI 3210-A ADI 3210-A Certified ISO 9001 Certified ISO 9001 High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters Warning: An appropriately sized pressure relief device downstream of the regulator
More informationEXD SERIES PRESSURE DIFFERENTIAL SWITCHOVER SYSTEM
EXD SERIES PRESSURE DIFFERENTIAL SWITCHOVER SYSTEM INSTALLATION AND OP ER A TION IN STRUC TIONS Before Installing or Operating, Read and Comply with These Instructions IMD0611B 6.2012 Certified ISO 9001
More information632 Series Gas Distribution System
ADI3223-B Certified ISO 9001:2000 632 Series Gas Distribution System INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation
More information453 Series Steam Heated Vaporizing Regulator
ADI 0453B Certifi ed ISO 9001 453 Series Steam Heated Vaporizing Regulator INSTALLATION AND OP ER A TION IN STRUC TIONS Before Installing or Operating, Read and Comply with These Instructions Controls
More information620 Series Switchover System
ADI 3174-E Certified ISO 9001 620 Series Switchover System (Shown with Optional Line Regulator) INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions
More informationAND OPERATION INSTRUCTIONS
ADI 2111-D Certified ISO 9001 MEDICAL FLOWMETER (Back Pressure Compensated Thorpe Tube) INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls
More informationProtocol Station INSTALLATION AND OP ER A TION IN STRUC TIONS. Before Installing or Operating, Read and Comply with These Instructions
ADI 3204-D Certified ISO 9001 Protocol Station INSTALLATION AND OP ER A TION IN STRUC TIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation of America 1501
More information655 Series Oxygen Blender
ADI 9905-A Certified ISO 9001 655 Series Oxygen Blender For use with High Pressure Industrial Gases in High Flow Applications INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read
More informationINSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures
INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures MINT-0289-XX TABLE OF CONTENTS Limited Warranty... 3 User Responsibility... 3-4 General Service... 4 Safety Precautions.... 5 Physical Dimensions..
More informationMachine Cutting Torches Series 4700
ADI 1580-E Certified ISO 9000 Machine Cutting Torches Series 4700 INSTRUCTIONS Before Installing, Operating or Servicing Read and Comply With These Instructions This symbol on the product means the product
More informationTri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS
Tri-Safem Model I1 Regulator INSTRUCTIONS and PARTS USER RESPONSIBILITY This equipment will perform in conformity with the description thereof contained In this manual and accompanying labels andlor inserts
More informationVolt 8000 Series Heated Regulator
ADI 3094-C Certified ISO 9001 115-230 Volt 8000 Series Heated Regulat INSTRUCTIONS Befe Installing, Operating Servicing Read and Comply With These Instructions This symbol on the product means the product
More informationInstallation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series
Introduction Powerex manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists of a regulator
More informationCertified ISO 9000 INSTALLATION AND OPERATION INSTRUCTIONS. Before Installing or Operating, Read and Comply with These Instructions
ADI 1219-M Certified ISO 9000 1600 Series Dual-Range Flowmeters INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation of America
More informationINSTRUCTION MANUAL GAS TRAK
INSTRUCTION MANUAL GAS TRAK 166 Keystone Drive Montgomeryville, PA 18936 Telephone: 215-641-2700 Fax: 215-641-2714 INT-0234 rev A1 TABLE OF CONTENTS SERVICE 3 LIMITED WARRANTY 3-4 USER RESPONSIBILITY 4-5
More informationINSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES
INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY FOR USE
More informationInstallation Operating Instructions for Duplex Manual Manifolds PX-TMD Series
Introduction Powerex manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists of a regulator
More informationINSTRUCTIONS FOR MODEL SSC LOW DELIVERY PRESSURE GAS REGULATORS
INSTRUCTIONS FOR MODEL SSC LOW DELIVERY PRESSURE GAS REGULATORS THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY FOR USE IN
More informationInstallation and Operating Instructions For MANUAL MANIFOLDS SD and SDHP SERIES
Installation and Operating Instructions For MANUAL MANIFOLDS SD and SDHP SERIES INTRODUCTION Western manifold systems are cleaned, tested and prepared for the indicated gas service and are built in accordance
More informationTri-Tech Medical Inc.
Introduction Tri-Tech Medical manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists
More informationNB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE
NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com
More informationV-24 OXYGEN LANCE VALVE
INSTRUCTIONS for F-4737-U May, 2009 V-24 OXYGEN LANCE VALVE w/ C -Size Inlet w/ B -Size Inlet V-24 Oxygen Lance with 1/8" Pipe Holder... 9728D65... 2218939 V-24 Oxygen Lance with 1/4" Pipe Holder... 9728A65...
More informationCITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard
CITY AND COUNTY OF DENVER CR&CF RISK UNIT 65.5.11 Compressed Gas Safety Standard 1.0 Introduction 2.0 Scope This standard has been developed to protect all City and County of Denver employees and contractors
More informationU S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.
U S E R M A N U A L 1600 SERIES OXYGEN REGULATOR 168715G (Shown) SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090
More informationCUTTING TORCHES SERIES
CUTTING TORCHES 9000 9500 9700 SERIES PARTS mis symbol on the product + means the product is nsted JULY 1996 by Underwriters Laboratories. Inc SUPERSEDES MARCH 1994 USER RESPONSIBILITY This equipment
More informationINSTRUCTIONS FOR HIGH PURITY, CHANGEOVER REGULATOR SYSTEMS (PCS, CRS SERIES)
INSTRUCTIONS FOR HIGH PURITY, CHANGEOVER REGULATOR SYSTEMS (PCS, CRS SERIES) THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY
More informationRS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.
RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationSSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR
S S F U SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR MACHINERY DIVISION OWNER S MANUAL UNIT INSTRUCTIONS Please follow all SSFU Safety Instructions. Contact your Duro Dyne Tech Service if you have
More informationINSTRUCTIONS FOR MODELS UPH & UPHS HIGH FLOW, HIGH PURITY GAS REGULATORS
INSTRUCTIONS FOR MODELS UPH & UPHS HIGH FLOW, HIGH PURITY GAS REGULATORS THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY
More informationINSTRUCTIONS FOR MODEL SG6500 GAS HEATERS
INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY FOR USE IN CONJUNCTION WITH MODEL
More informationPortable Compressed CO 2 Regulator
Portable Compressed CO 2 Regulator 99901 Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com
More informationInstallation & Maintenance Manual. C2 & C3 Manifolds
Installation & Maintenance Manual C2 & C3 Manifolds w w w. a m i c o. c o m Table of Contents User Responsibility 3 Introduction 4 Features 4 Description of the Manifold 5 Shipment Details 5 Description
More informationEconomy Manifold Alert -2. Installation and Maintenance Manual V1.6
Economy Manifold Alert -2 Installation and Maintenance Manual V1.6 Corporation Table of Contents User Responsibility 4 Introduction 4 Features 4 Description of the Manifold 5 Shipment Details 5 The Collapsible
More information- GAS REGULATOR - COMPACT STYLE
INSTRUCTIONS FOR USE - GAS REGULATOR - COMPACT STYLE Preset at 50 or 60 psi Rx ONLY GR - XXX - [(TT) (UU) - (XX)(Z)] GR XXX (TT) (UU) (XX) (Z) Gas Connection Outlet Flowrate Addition Outlet Additional
More informationINSTRUCTIONS FOR SINGLE STAGE LECTURE BOTTLE REGULATORS
INSTRUCTIONS FOR SINGLE STAGE LECTURE BOTTLE REGULATORS THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY FOR USE IN CONJUNCTION
More informationInstruction manual. for. high purity gas pigtails 200 bar / 300 bar
Instruction manual for high purity gas pigtails 200 bar / 300 bar Contents Contents... 2 1. Preface... 3 1.1 Overview... 3 1.2 General... 3 1.3 Intended use... 4 1.4 Personnel requirements... 4 2. For
More informationYoke Block Instruction Manual
Yoke Block Instruction Manual ! WARNING IMPORTANT: READ MANUAL COMPLETELY BEFORE OPERATING THIS DEVICE This manual contains instructions on periodically required checks to be performed by the user. These
More informationModel ASSEMBLY and OPERATING INSTRUCTIONS
QUICK CHANGE AIR BRUSH KIT Model 93506 ASSEMBLY and OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd.,
More informationPressure Differential Automatic Manifold For LPG. PDH1000 Series. LPG Installation & Operations Instructions
Pressure Differential Automatic Manifold For LPG PDH1000 Series LPG Installation & Operations Instructions Precise Equipment Company 3822 Market St., STE 101 Denton, Texas Phone : 800.795.8388 Precise
More informationInstallation & Maintenance Manual. Economy Manifold
Installation & Maintenance Manual Economy Manifold Contents User Responsibility 3 Introduction 4 Features 4 Description of the Manifold 5 Shipment Details 5 Description of Parts 5-6 Pressure Regulators
More informationLRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.
LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the
More informationDFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)
DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER) 0-3, 0-15, 0-30 & 0-70 LPM ASSEMBLY INSTRUCTIONS & INSTRUCTIONS FOR USE R219P87-400 (0-70 LPM) R219P88-400 (0-30 LPM) R219P79-400 (0-15 LPM) R219P99-400
More informationThis written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.
Safety & Health Program 10627 Midwest Industrial Boulevard, St. Louis, MO Phone: 314-785-6425 Fax: 314-785-6426 Compressed Gas Plan Purpose It is the policy of EMA to permit only trained and authorized
More informationPressure Relief Valve Instruction Manual
CVR3-M0_062017 Pressure Relief Valve Instruction Manual MODEL: CVR3 SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 * Fax: 816-448-2142 E-mail: sales@bvahydraulics.com Website:
More informationOperating Manual. R280 Pressure regulator made of brass. 1. Intended Use
Pressure regulator made of brass Operating Manual 1. Intended Use Line or outlet pressure regulators- /reducer for Air, gases and liquids which is designed to effect reduction to a downstream pressure
More informationNEMA 4 IntelliSwitch TM Electronic Switchover
ADI 9503-A Certified ISO 9001:2000 NEMA 4 IntelliSwitch TM Electronic Switchover Patent Pending INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation
More informationPARTS, SERVICE & REPAIR BULLETIN
WH4C PARTS, SERVICE & REPAIR BULLETIN 400 SERIES HEAVY DUTY WELDING HANDLE Manual No: 0056-3763 Issue Date: October 07, 03 Revision: AA VictorTechnologies.com Table of Contents SECTION : GENERAL SAFETY
More informationJ Air and Water Kit Instructions Part# 02584
J Air and Water Kit Instructions Part# 02584 Unpacking Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you
More informationYoke Block Instruction Manual
Yoke Block Instruction Manual ! WARNING IMPORTANT: READ MANUAL COMPLETELY BEFORE OPERATING THIS DEVICE This manual contains instructions on periodically required checks to be performed by the user. These
More informationTHE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301
THE HF-300 SERIES Operating and Service Manual Series includes all variants of HF-300/301 Issue A July 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 3.1. Spring Loaded...
More informationINSTRUCTIONS FOR MODEL TSC LOW DELIVERY PRESSURE GAS REGULATORS
INSTRUCTIONS FOR MODEL TSC LOW DELIVERY PRESSURE GAS REGULATORS THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY FOR USE IN
More informationD Series Air and Water Kit Part# 02550
D Series Air and Water Kit Part# 02550 Unpacking Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you undamaged.
More informationPush-To-Set Intermittent Suction Unit (PTS-ISU) Instructions for Use
Push-To-Set Intermittent Suction Unit (PTS-ISU) Instructions for Use F H M L F H M L MEDICAL VACUUM Analog Digital 8700-0000-000 (Rev.7) 05/2010 Regulator Identification Push-To-Set TM Intermittent Suction
More informationREDLINE pressure regulators for GENIE cylinders.
Instruction manual Instructions. REDLINE pressure regulators for GENIE cylinders. 02 03 Operating instructions for cylinder pressure regulators. Linde reserves the right to change product specifications
More informationTHE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)
THE BP-301 SERIES Operating and Service Manual Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) Issue B October 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation...
More informationaccidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS
18 GAUGE 2 INCH BRAD NAILER Model: 7555 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
More informationCylinder Tilt Saddle Instruction Manual
Cylinder Tilt Saddle Instruction Manual MODELS: SDT05, SDT10, SDT15, SDT25 SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 - Fax: 816-448-2142 E-mail: sales@bvahydraulics.com
More informationInterface Devices, Inc. Hydraulic Mini Mule
Interface Devices, Inc. Hydraulic Mini Mule INSTALLATION, OPERATION & MAINTENANCE MANUAL IMPORTANT! FILE THIS MANUAL IN A SAFE PLACE FOR FUTURE SERVICE & PARTS NEEDS ALWAYS REFERENCE THE SERIAL NUMBER
More informationaccidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS
18 GAUGE 1-1/4 INCH BRAD NAILER Model: 7611 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
More informationIntelliSwitch II Electronic Switchover
ADI 9515-I IntelliSwitch II Electronic Switchover TM INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501
More information4-in-1 Professional Inflator Kit
4-in-1 Professional Inflator Kit Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
More informationGeneral Precautions for handling compressed gases
General Precautions for handling compressed gases Introduction Compressed gas cylinders can be extremely hazardous when misused or abused. Compressed gas cylinders can present a variety of hazards due
More informationBefore using or working with the Grab n Go Heliox system, please read and understand the usage and safety instructions provided in this booklet.
Operating Instructions for the Before using or working with the Grab n Go Heliox system, please read and understand the usage and safety instructions provided in this booklet. Introduction The Praxair
More informationInstruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013
Instruction Sheet 102-492 5123-WH-N Lead Free (.25% Pb) Mixing Valve SUPERSEDES: New EFFECTIVE: August 1, 2013 Plant I.D. 001-4206 WARNING: Water temperatures above 120 F can cause serious injury. Mixing
More informationAIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST
AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST OIL-LESS TYPE IMPORTANT: PLEASE READ CAREFULLY BEFORE STARTING OPERATIONS. THE CONTENTS ARE FOR GENERAL INFORMATION OF ALL THE SIMILAR MODELS. Record
More informationINSTRUCTIONS FOR SERIES 150 TWO TUBE GAS BLENDER
INSTRUCTIONS FOR SERIES 150 TWO TUBE GAS BLENDER THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY FOR USE IN CONJUNCTION WITH
More informationPRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.
PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationCompact Triple Cabinet Outlet Station Model Installation and Operating Instructions
Compact Triple Cabinet Outlet Station Model 6258-1 Installation and Operating Instructions The Porter Compact Triple Outlet Station (6258-1) provides a quick, safe, and reliable method of connection to
More informationINSTRUCTIONS FOR FM4460N SERIES HIGH PRESSURE, METAL TUBE FLOWMETERS
INSTRUCTIONS FOR FM4460N SERIES HIGH PRESSURE, METAL TUBE FLOWMETERS THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY FOR
More informationInstruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.
Instruction Manual Hydraulic Punch Driver 902-483 LIMITED 1 YEAR WARRANTY We make every effort to assure that its products meet high quality and durability standards, and warrant to the original purchaser
More informationAIR INLINE METAL SHEAR
AIR INLINE METAL SHEAR ASSEMBLY and OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd. / Camarillo, CA 93011 Copyright 1997 by Harbor Freight Tools. All rights reserved. No portion of this manual or any artwork
More informationTHE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401
THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special
More informationUser Operation Manual and Safety Instructions
PCP Airgun Charging Station 74 cu.ft. / 98 cu. ft. Carbon Fiber Tank & Accessories User Operation Manual and Safety Instructions BRAND: Air Venturi DESCRIPTION: PCP Airgun Charging System FILL PRESSURE:
More informationINSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)
P/N 126905-01 Rev. B 11/2016 INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235) For All Single, Dual and Triple Burner Natural and Propane/LP Gas Logs P126905-01 For
More informationNote: You will need a full tank of CO2 for connection and leak testing! Kit Number
Owners Manual Design Engineering Inc. CryO2 Cryogenic Tank Installation Kit To be used with CryO2 components only! Persons experienced in the installation and proper operation of Performance systems like
More informationACRYLIC FLOW METERS 0-30, 0-70 & LPM
ACRYLIC FLOW METERS 0-30, 0-70 & 0-120 LPM ASSEMBLY INSTRUCTIONS & INSTRUCTIONS FOR USE R219P86 (0-120LPM) R219P87 (0-70LPM) R219P88 (0-30 LPM) R138P11 Rev. D TABLE OF CONTENTS: 1.0 PRODUCT OVERVIEW...1
More informationTESCOM 50-4X Series Safety, Installation & Start-Up Procedures
Operations & Service Manual TESCOM 50-4X Series Safety, Installation & Start-Up Procedures Do not attempt to select, install, use or maintain this product until you have read and fully understood this
More informationSafe Work Instructions For Oxygen Acetylene Equipment
Safe Work Instructions For Oxygen Acetylene Equipment Policy Sponsor: Assistant Vice President Facilities Management Responsible Unit: Trade Services Approval Date: September 2010 Revisions: January 2018
More informationINSTRUCTIONS FOR MODELS APC & APG HIGH PURITY, CORROSIVE GAS REGULATORS
INSTRUCTIONS FOR MODELS APC & APG HIGH PURITY, CORROSIVE GAS REGULATORS THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY FOR
More informationThermo Valves Corporation
Scuba Diving Valves Maintenance Manual The Leader in High Pressure Technology Date: 07/31/05 Thermo Scuba Products are Sold Through Authorized Distributors Only Thermo PRO Thermo Modular This document
More informationBauman Machine Inc. COMPRESSED GAS CYLINDER SAFETY
Bauman Machine Inc. COMPRESSED GAS CYLINDER SAFETY Many industrial and laboratory operations require the use of compressed gases for a variety of different operations. Compressed gases present a unique
More informationTechnical Operating Instructions for Magnum Cutting Systems. for online instructions
Technical Operating Instructions for Magnum Cutting Systems http://www.magnumusa.com/operating-video.html for online instructions In Case of Emergency Immediately Call for Medical Aid. Familiarize yourself
More information2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL
2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL Model: 52024 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement,
More informationTypes 749B and R130 Changeover Manifolds
Instruction Manual MCK-1179 Types 749B and R130 June 2012 Types 749B and R130 Changeover Manifolds TYPE HSRL-749B TYPE 64SR/122 TYPE R130/21 TYPE 749B/21 Figure 1. Changeover Manifolds and Regulator Assemblies
More informationRD(H)20/25 Pressure-Reducing Regulator User Manual
RD(H)20/25 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be
More informationAuto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL
Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL Introduction Thank you for purchasing a Retracta Auto Rewind Hose Reel. The Retracta range of hose reels are a breakthrough in industrial quality
More information1/2 Twin Hammer Composite. Air Impact Wrench ASSEMBLY AND OPERATING INSTRUCTIONS
1/2 Twin Hammer Composite Air Impact Wrench 95098 ASSEMBLY AND OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission
More informationPremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION
DUAL SUPPLY REGULATOR ESCAPE CYLINDER VORTEX MAIN INLET PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY
More informationMaterial Handling and Storage of compressed gases and Air equipment
Material Handling and Storage of compressed gases and Air equipment Compressed gases can be toxic, flammable, oxidizing, corrosive, inert, or some combination of these hazards. Compressed gas cylinders
More informationHYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)
Form No. 102897 Operating Instructions for: HB443 HB444 HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg) Definition: A devise that raises the inlet pressure to
More informationRK-IR Sample Draw Aspirator Adapter Operator s Manual
30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment
More information