XML Electromechanical Pressure Switches
|
|
- Jane Todd
- 6 years ago
- Views:
Transcription
1 Selection Guide Industrial Switches Type of installation ontrol circuits Applications Media controlled Type of operation Air, water, hydraulic oils, corrosive fluids, viscous products Fixed differential: etection of a single threshold Adjustable differential: Regulation between two thresholds ual-stage switches: Fixed differential, detection at each threshold Fluid characteristics Size (pressure range) imensions of case (mm) width x height x depth Air, fresh water, sea water, corrosive fluids, viscous products, up to 0 F (60 ) depending on model to 500 bar (.5 to 750 psi) 5 x 68 x 75 6 x 68 x 85 5 x 68 x 75 Type of contacts /O single-pole, snap action /O single-pole, simultaneous, snap action /O single-pole, snap action egree of protection IP 66 with terminal connections IP 65 with plug-in connector IP 66 with terminal connections IP 66 with terminal connections IP 65 with plug-in connector Agency listings connection connection UL, SA,, BV, LROS, RINA, GL, NV, VIT-SEPRO Screw terminals: tapped entry: / NPT; M0 x.5 mm for ISO conduit/cable; or PG.5 conduit/cable entry onnector: IN 650, M G (BSP female) G - (BSP female) for viscous products atalog number XMLA XMLB XML XML Pages pages 0 78 Other versions For electromechanical pressure and vacuum switches with alternative tapped cable or fluid entries, consult your local sales office.
2 Industrial Switches XMLA Introduction XML pressure and vacuum switches for control circuits are used to control the pressure of hydraulic oils, fresh water, sea water, air, steam, corrosive fluids, or viscous products, up to 750 psi (500 bar). XMLA pressure and vacuum switches have a fixed differential and are for detection of a single threshold. They incorporate a /O single-pole contact. XMLB pressure and vacuum switches have an adjustable differential and are for regulation between two thresholds. They incorporate a /O single-pole contact. XML pressure and vacuum switches have an adjustable differential and are for regulation between two thresholds. They incorporate two /O single-pole contacts. XML pressure and vacuum switches are dual-stage switches, each stage with a fixed differential, and are for detection at each threshold. They incorporate two /O single-pole contacts (one per stage). Setting XMLA: and vacuum switches with fixed differential XMLB, XML Rising pressure Operating point PH is set by adjusting the red screw (). Falling pressure Operating point PB is not adjustable. The difference between the trip and reset points of the contact is the inherent differential of the switch (contact differential, friction, etc.). XMLB and XML: and vacuum switches with adjustable differential When setting the pressure and vacuum switches, first adjust the operating point on rising pressure (PH), then the operating point on falling pressure (PB). Rising pressure Operating point PH is set by adjusting the red screw (). Falling pressure Operating point PB is set by adjusting the green screw (). XML: ual-stage pressure and vacuum switches with fixed differential for each threshold Operating point on rising pressure of stage and stage First stage operating point on rising pressure (PH) is set by adjusting the red screw (). Second stage operating point on rising pressure (PH) is set by adjusting the blue screw (). Operating point on falling pressure The operating points on falling pressure (PB and PB) are not adjustable. The difference between the trip and reset points of each contact is the inherent differential of the switch (such as contact differential or friction). 0
3 Industrial Switches Table : Environmental specifications onformity to standards e, IE/EN , UL 508, SA - n Product certifications Protective treatment UL, SA,, BV, LROS, RINA, GL, NV, VIT-SEPRO Standard version T. Special version TH Ambient air temperature, F ( ) For operation: to +58 ( 5 to +70). Storage: 0 to +58 ( 0 to +70) Fluids or products controlled Hydraulic oils, air, fresh water, sea water, 0 F (0 to 60 ), depending on model Steam, corrosive fluids, viscous products, 0 F (0 to 60 ), depending on model Materials ase: zinc alloy. omponent materials in contact with fluid: see pages Operating position Vibration resistance Shock resistance All positions gn ( Hz) conforming to IE except XML L5, XML 00 and XMLBM0 : gn 50 gn conforming to IE except XML L5, XML 00 and XMLBM0 : 0 gn Electric shock protection lass I conforming to IE 0, IE 56 and NF 0-00 egree of protection Operating rate (operating cycles/minute) Repeat accuracy < % connection () onnection () for screw terminal models Screw terminal models: IP 66 conforming to IE/EN 6059 onnector models: IP 65 conforming to IE/EN 6059 Piston version switches: up to 60 cycles/minute for temperatures greater than F (0 ) iaphragm version switches: up to 0 cycles/minute for temperatures greater than F (0 ), G / (BSP female) conforming to NF E 0-005, ISO 8 /" NPTF female PT / (JIS B00). /" NPT electrical connections ISO M0 x.5 tapped entry IN Pg.5 (n ) tapped entry onnector models, either M or IN 650 A: consult your local sales office. () See page 0, Interpretation of the atalog Number for XML evices, for more information on specifying the electrical and pressure connections. Table : ontact block specifications a A-5; B00 (Ue = 0 V, Ie =.5 A - Ue = 0 V, Ie = A) Rated operational specifications c -; R00 (Ue = 50 V, Ie = 0. A) conforming to IE Appendix A, EN Ui = 500 V conforming to IE/EN Rated insulation voltage Ui = 00 V conforming to UL 508, SA - n Rated impulse withstand voltage U imp = 6 kv conforming to IE/EN Type of contacts Silver tipped contacts XMLA and XMLB: /O single-pole contact ( terminal), snap action XML: /O single-pole contacts (8 terminal), simultaneous, snap action XML: /O single-pole contacts (8 terminal), staggered, snap action Resistance across terminals (m ) < 5 conforming to NF method A or IE 55-7 category Terminal referencing onforming to ENELE EN 500 Short-circuit protection 0 A cartridge fuse type gg (gl) onnection Screw clamp terminals. lamping capacity, min: x 0. mm, max: x.5 mm durability onforming to IE/EN Appendix Utilisation categories A-5 and - XMLA and XMLB A supply a 50/60 Hz o Inductive circuit, lthe = 0 A XML and XML A supply a 50/60 Hz o Inductive circuit, lthe = 0 A Operating rate: 600 operating cycles/hour Load factor: 0.5 Millions of operating cycles V 8 V Ithe 0 V Millions of operating cycles V 8 V / V Ithe urrent in A 0. 0 V urrent in A supply c Power broken in W for million operating cycles supply c Power broken in W for 5 million operating cycles Voltage V 8 0 Voltage V 8 0 o W 9 6 o W 0 7
4 Industrial Switches 0 Interpretation of the atalog Number for XML evices Table 9: Interpreting the atalog Number (Example: XMLA00AS) esignation Nautilus Switch Nonadjustable differential, single pole Adjustable differential, single pole Type Adjustable differential, double pole Nonadjustable differential, double pole Operating range bar (psi) Input fluid isplay XML A 00 A S atalog Number XML 0.05 L L5 0.5 Overpressure 0.0 (.5) S5 to 0.8 M0 to 0. M0 0. to 0.0 M0 0.5 to 5 M Overpressure 0.0 (.5) S0 00 Overpressure 0.0 (.5) S Overpressure 0.0 (.5) S Overpressure 0.0 (.5) S iaphragm type Hydraulic oils, air, fresh, or sea water, 58 F (0 70 ) A Hydraulic oils, air, fresh, or sea water, 0 F (0 60 ) B orrosive fluid Viscous products P Hydraulic oils or air, 0 F (0 60 ) R Fresh or sea water, 0 F (0 60 ) S Vacuum type with diaphragm Hydraulic oils, air, fresh or sea water, 58 F (0 70 ) V Hydraulic oils, air, fresh or sea water, 0 F (0 60 ) T Piston type Hydraulic oils or air, 0 F (0 60 ) Fresh or sea water, 0 F (0 60 ) E orrosive fluid, 0 F (0 60 ) N Not provided Provided Threaded hole IN 650 connector M threaded connector (Micro hange type) S onnection ontact type ry contact European G / (BSP female) Type (Pg.5) G / (BSP female) ISO M0 Entry type U.S.A. / in. NPTF / in. NPT Japan PT / (JIS B00) / in. PF (JIS B00) Options May indicate factory setting A B
5 Selection and Specifications Industrial Switches Table 50: Size 60 bar (0 psi) Fixed differential, for detection of a single threshold Switches with /O single-pole contact connection /" NPT or /" BSP Switches, Type XMLA With setting scale Without setting scale Adjustable Range of Operating Point (PH) (Rising pressure) 0 60 bar (5 0 psi) onnection Terminals IN connector Terminals IN connector atalog Numbers () Fluids ontrolled () Hydraulic oils, up to 0 F (60 ) Fresh water, sea water, up to 0 F (60 ) orrosive fluids, air, up to 0 F (60 ) XMLA60S XMLA60 XMLA60S XMLA60 XMLA60ES XMLA60E XMLA60ES XMLA60E XMLA60NS XMLA60N XMLA60NS XMLA60N Weight, lb (kg).65 (0.750).7 (0.780).65 (0.750).7 (0.780) Supplementary Specifications (not shown under general specifications) Inherent ifferential At low setting 5.5 bar (79.75 psi), ± bar (±.5 psi) (subtract from PH to get PB) At high setting 8 bar (6 psi), ± bar (±.5 psi) Maximum Allowable Per cycle 00 bar (900 psi) Accidental 60 bar (50 psi) estruction 70 bar (0,0 psi) Mechanical life 6 x 0 6 operating cycles able Entry and Wire Size for Terminal Models /" NPT, x 0. mm² minimum, x.5 mm² maximum. onnector Type for onnector Models IN 650A, -pin male. For suitable female connector, see page 7. Switch Style Piston () For entry tapped for PG.5 conduit/cable entry, replace S with S (example: XMLA60S becomes XMLA60S). () omponent materials of units in contact with the fluid, see pages Operating urves Rising pressure bar Other Versions bar Falling pressure PH PB Adjustable value --- Non adjustable value onnection Terminal model onnector model For switches with alternative tapped cable entries (such as NPT), consult your local sales office. Time switch connector pin view and 6
Electromechanical pressure switches
References : pages / and / page /5 Presentation Functions Pressure switches type XMX and XMA are switches for control circuits, with an adjustable differential. They are used to control the pressure of
More informationElectromechanical pressure switches
Presentation Electromechanical pressure switches OsiSense XM For power circuits, type XMP Presentation Pressure switches type XMP are switches for power circuits (direct switching), with an adjustable
More informationLimit switches OsiSense XC Special For material handling applications, type XC1 AC
Presentation For material handling applications, type XC C b XC C with slow break contacts v With head for linear movement () 00_ 00_ 000_ Page / 00_ 00_ XCC XCC Page / XCC XCC / General characteristics
More informationXMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type
Characteristics pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type Main Range of product Pressure sensor type Pressure sensor name Pressure sensor size OsiSense XM Electromechanical
More informationReferences, characteristics. References (1) Complementary characteristics not shown under general characteristics (page 30395/3)
References, characteristics Electromechanical pressure switches For power circuits, type XMP. IP degree of protection Size (87 psi). Adjustable differential, for regulation between thresholds Switches
More informationZelio Relays RSL Slim Interface Plug-In Relays
Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3
More informationModel range*1) Switching pressure difference
Pneumatic pressure switch electromechanical actuated -...00 bar, G/2 Microswitch with gold plated contacts Intrinsically safe operation Electrical connection: connector acc. to IN EN 7530-803 (form A)
More informationDifferential pressure controls, Type MP 54, 55 and 55A
MAKING MODERN LIVING POSSIBLE Technical brochure Differential pressure controls, Type MP 54, 55 and 55A MP 54 and oil pressure controls are used as safety switches to protect refrigeration compressors
More information1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure
Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3
More informationPrewired position switches FA series
2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45
More informationPosition switches FP series
A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever
More informationTechnical explanations for mechanical pressure switches
Technical explanations for mechanical pressure switches 7 6 5 4 7 5 6 4 Diaphragm pressure switch NO Piston pressure switch NC Change over 3 2a 1 3 2b 10 9 What is a mechanical pressure switch? Mechanical
More informationPressure switch and Thermostat CAS
Data sheet Pressure switch and Thermostat CAS The CAS Series consists of a series of pressure controlled switches and temperature controlled switches. In this series, special attention has been given to
More informationPressure switch and Thermostat Type KPS
MAKING MODERN LIVING POSSIBLE Data sheet Pressure switch and Thermostat Type KPS The KPS Series consists of a series of pressure and temperature controlled switches. In this series, special attention has
More informationThe Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure
General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal
More informationPrewired position switches FA series
Prewired position switches Technical data Housing Made of metal, coated with baked epoxy powder 2 m wired cable with 5x0,5 mm 2 wires marked SEV and IMQ Protection degree: IP6 General data Ambient temperature:
More informationDifferential Pressure Control Types MP 54, MP 55 and MP 55A
MAKING MODERN LIVING POSSIBLE Data sheet Differential Pressure Control Types MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure controls are used as safety switches to protect refrigeration
More informationData sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119
Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,
More informationPressure switch and Thermostat KPS
Data sheet Pressure switch and Thermostat KPS The KPS Series consists of a series of pressure and temperature controlled switches. In this series, special attention has been given to meeting demands for
More informationPressure Measurement Single-range transmitters for general applications
Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials
More informationTeSys protection components
Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More information2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure
Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationPressure switches for air and water CS
Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the
More informationDifferential pressure switch MP 54, MP 55 and MP 55A
Data sheet Differential pressure switch MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors against low lubricating
More informationData sheet. Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E B0782
Data sheet Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E2.02 520B0782 Survey Type KPS pressure switches 1. Standard pressure switches Range Further -1 0 10 20 30 40 50 60 bar P e Type
More informationPressure switch for gas and air
Pressure switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF GXX_A4
More informationPressure switches and thermostats, type KPS
Description KPS units are pressure-controlled switches. The position of the contacts depends on the pressure in the inlet connection and the set scale value. In this series, special attention has been
More informationPressure switch KP-E. Data sheet
Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches
More informationPressure Switch for gas and air GGAO-A4
Pressure Switch for gas and air GGAO-A4 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 Commonwealth of Massachusetts Approved Product Approval code G3-0106-191 Gas pressure switch Codes
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationPressure Switches Application Guideline
Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment
More informationPressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. 13 and No. 0 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
More informationThin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1.
Thin pressure gauge G401-W Series Thin, compact design ideal for incorporating devices. Suitable for filter regulator, regulator, and pressure switch (P4000-W). onnection: O ring seal, set screw G401-W
More informationPRODUCT SPECIFICATION
MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit
More informationRP series Rotor Pumps
ontact etails RP series Rotor Pumps Nomenclature Features Low noise Substantial reduction of the operation noise, by to db (comparison with aikin products), and improved sound quality are achieved by adopting
More informationDMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.
Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:
More informationTightness controls TC 1 3 and TC 4
Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems
More informationPressure controls for hydro carbons, zone II applications, Type KPE
MAKING MODERN LIVING POSSIBLE Technical brochure Pressure controls for hydro carbons, zone II applications, Type KPE KPE pressure controls for use in refrigeration and air conditioning systems with hydrocarbons
More informationPressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
More informationLevel switches Series LD Vibrating fork level switch for liquids and solids
Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant
More informationLevel switches Series LD Vibrating fork level switch for liquids and solids
Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant
More informationRelated products. Components for air preparation and pressure adjustment / F.R.L. unit. Pressure gauge. Indidcator
Related products Pressure gauge / indicator omponents preparation and pressure adjustment / unit Refrigerating ir uto. drain ir Pressure gauge ONTENTS Pressure gauge assembly (G401-W) 660 With safety mark
More informationOPTIBAR P 1010 C Technical Datasheet
Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability
More informationDual Solenoid Gas Valve Installation
Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions
More informationCALEFFI. Ball zone valves. series /03 GB
all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the
More informationTechnical explanations for mechanical pressure switches
Technical explanations for mechanical pressure switches 7 6 5 4 7 5 6 4 Diaphragm pressure switch NO Piston pressure switch NC Change over 3 2a 1 3 2b 10 9 What is a mechanical pressure switch? Mechanical
More informationGas Pressure Switch for DMV safety shutoff valves
Gas Pressure Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL File # MH 668 CSA Certified CSA C. No. LR File # 07 FM Approved Class 0, 0 File # J.I. Y9A9.AF Commonwealth of Massachusetts
More informationP9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6
P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,
More informationEmergency Stop Devices/Rope Pull Switches
Rope pull switch with pulltoreset button for emergency stop device Metal housing Emergency stop device with detent mechanism according to EN ISO 13850 and EN 602041 Clamping head for pull rope Indication
More informationP9000 Series Pressure Transducer
High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESRIPTION The P9000 Series is a range of advanced,
More informationOperating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073
Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4
More informationDifferential pressure switch / Lube oil protection control MP 54 and MP 55
Data sheet Differential pressure switch / Lube oil protection control MP 54 and MP 55 MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors
More informationDiaphragm pressure switches, 42 V
0166 Diaphragm pressure switches, 42 V Zinc-plated steel body With push-on terminals Overpressure safe to 300 bar *) 0166 Diaphragm pressure switches Adjustment range Thread Normally open (no) : Normally
More informationProduct Catalogue MINICOMB. Switches for Pressure and Vacuum
Product Catalogue MINICOMB Switches for Pressure and Vacuum PL ATEX 2 DEFINITION OF PRESSURE A force applied uniformly over a certain area is called pressure: p = F / A (pressure = force / area) Pressure
More informationQPL... Pressure Switches. Siemens Building Technologies HVAC Products
7 221 Pressure Switches QPL... The pressure switches are used for monitoring gas or air pressures. When the pressure falls below the switching point, the associated electrical circuit will open or switch
More informationP900. P900, Datenblatt Seite 1 DESCRIPTION
, Datenblatt Seite 1 Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and
More informationMechanical Pressure Switches for overpressure, vacuum pressure and differential pressure
Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure Switching range: -250 +100 mbar, 1 16 mbar to 16 63 bar Temperature: max. 70 C Material: Copper, brass, stainless
More informationPressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview
f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationTURQUOISE SWITCHES ABJ (BJ) SWITCHES
Ultra-miniature Size Sealed Switches TURQUOISE SWITCHES ABJ (BJ) SWITCHES Terminal type Mounting hole 2.3 mm type FEATURES Ultra-miniature size, High sealing performance sealed switches Elastomer double
More information3.0 Pressure Transmitter Selection
3.0 Pressure Transmitter Selection Each Tronic Line pressure transmitter has different features to meet specific performance, environmental, and price requirements. It is not possible to describe every
More informationCompact differential pressure switch Flameproof enclosure Ex d Models DE, DEC
Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring
More informationGas Pressure Switch for DMV safety shutoff valves
Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts
More informationCim 787 Variable orifice balancing valve
im 787 Variable orifice balancing valve 787 im 787 balancing valves are suitable for both heating (LPHW) and cooling applications. They are available in ZR brass (im 787) or in standard brass (im 787OT).
More informationClimatic Independent Level Sensor LAR
1 Product Information LAR-361 LAR-761 Climatic Independent Level Sensor LAR Application / Specified usage Authorizations Hydrostatic level measurement in humid ambiance Special applicable for exterior
More informationValve Proving System VDK 200 A S06*
Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
More informationNorth American Pressure Switches
Combustion North American Pressure Switches Bulletin 8757 Pressure switches are used with Automatic Shutoff Valves or Solenoid Valves to interrupt fuel flow in the event of fuel or air failure. They are
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20
More informationGas Pressure Switch for DMV safety shutoff valves
Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts
More informationellison sensors international
PR3900 HAZARDOUS AREA PRESSURE TRANSMITTER ATEX CERTIFIED AND ALL EQUIVALENTS FOR HAZARDOUS AREAS: ZONE 0 GAS GROUP IIC, TEMPERATURE CLASS T4 AND ZONE 20 DUST PROTECTION BY INTRINSIC SAFETY TO EEXIA IIC
More informationType S-10, S-11 General Purpose Pressure Transmitters
Electronic Pressure Catalog > General Purpose > S-10, S-11 Type S-10, S-11 General Purpose Pressure Transmitters Applications Hydraulics and pneumatics Test equipment Pump and compressor control Liquid
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationCLARK 200 Series Vortex Flow Transmitter Frequency Output, 1/4 to 1.0 Pipe Sizes, Rugged Molded PPA Construction
www.clarksol.com LRK 200 Series Vortex Flow Transmitter Frequency Output, 1/4 to 1.0 Pipe s, Rugged Molded PP onstruction DESRIPTION The series 200 vortex flow transmitters are designed with equipment
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting
More informationATM.1ST. Pressure transmitters CUSTOMER BENEFITS
Pressure transmitters ATM.1ST CUSTOMER BENEFITS High precision pressure sensor over the whole temperature range Electronic compensation Modular sensor structure (any process and electrical connections
More informationEXH. Specifications. Descriptions. Min. working pressure MPa
Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,
More informationProp. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08
Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size
More informationBDT20 Safety process pressure gauge 100 & 160mm
BDT20 Safety process pressure gauge 100 & 160mm Product description Badotherm pressure gauge model BDT20 is the solid front, safety pattern gauge according the highest class of the EN 837-1 / 9.7.2 and
More informationTypes and approvals. Page 1/6. Data Sheet
Page 1/6 Panel-mounting Thermostats EM Series as: Protection temperature monitor STW (STB) Protection temperature limiter STB tested to DIN 3440 and Pressure Equipment Directive 97/23/EC Brief description
More informationMultiple Connection Manifolds
ultiple onnection anifolds PNUAYN, IN. atalog 2400 Phone 763-559-0177 ax 763-559-0547 eatures l 2 to 10 stations l Inline anifolds, 90 anifolds, ual Air, unction locks and Terminal locks l ustom designs
More informationPressure switch Model PS01
Mechatronic pressure measurement Pressure switch Model PS01 Switzer data sheet PS-PS01 Applications Hydraulics and pneumatics Steel Power Special purpose machine Special features Diaphragm-sealed piston
More informationCMC Series Moulded Case Circuit Breaker Cielo Electric
Model name CMC: Series 225: mpere frame size Line side terminal In: Rated current Ue: Rated operational voltage Icu: Rated ultimate short-circuit breaking capacity Ta: mbient temperature In: 225 Icu: 55k@415V
More informationSPECIFICATIONS ATTENTION
VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane
More informationValve Proving System VDK 200 A S02
Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
More informationInductive Proximity Sensors Global Plus Prox
July 2005 PG.05..T. -35 Global Plus ontents Overview................... -35 Model Selection, Sensors...... - Model Selection, ompatible onnector ables........... -37 Model Selection, ccessories... -37
More informationStainless steel valves for corrosive environments & water base fluids
www.atos.com Table E135-10/E Stainless steel valves for corrosive environments & water base fluids explosion-proof soleid valves, with tex, IEEx or UL US certification and pressure relief valves LOHX(S)6-3/M-O/V
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or
More informationAMS 2710 PCB pressure sensor module with V output
FEATURES Universal pressure sensor module with 0.. 10 V voltage output Fully calibrated and temperature compensated sensor module Variants for (bidirectional) differential, gage, absolute and barometric
More informationPressure switch Type BCP
Data sheet Pressure switch Type BCP The BCP type is a series of dedicated switches for safety and monitoring of steam and hot water boilers. The BCP incorporates a single-pole changeover microswitch where
More informationFlow Sensors & Hydrometers Specification Sheet
Baseline Flow s and Hydrometers Baseline s smart flow sensors and hydrometers are two-wire ready flow measurement and control devices that are pre-programmed with the correct K and Offset values. In addition,
More informationPressure controls, differential pressure controls type RT
Data sheet Pressure controls, differential pressure controls type RT Introduction Features An RT pressure control contains a pressure operated single-pole changeover contact, the position of which depends
More informationSKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function
SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25
More informationSPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection
SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces
More informationPressure Transmitters 36 F-27839
Pressure Transmitters 36 F-27839 SPD310/SPD360 Air Differential schneider-electric.com 37 SPD310/SPD360 SPD310/SPD360 differential pressure transmitters are intended for use in air handling systems for
More informationATM.ECO - Analog Pressure Transmitter
Pressure Transmitter ATM.ECO - Analog Pressure Transmitter CUSTOMER BENEFITS Entry level series into precision pressure measurement High measurement accuracy is ensured by sophisticated digital temperature
More informationPRESSURE SWITCHES Bulletin 8757
PRESSURE SWITCHES Bulletin 8757 September 2013 Pressure switches are used with Automatic Shutoff Valves or solenoid valves to interrupt fuel fl ow in the event of fuel or air failure. They are also used
More informationED 701 Hygenic Pressure Transmitter
ED 701 Hygenic Pressure Transmitter Hygienic process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response time < 25 ms (Option
More informationAutomatic Valve Proving Control
ISO 9001 Automatic Valve Proving Control 7 696 LDU11 UL recognized FM approved Features Performs leak test of the gas shut-off valves before start-up and/or immediately after burner shut-down No inlet
More information