BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

Size: px
Start display at page:

Download "BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-"

Transcription

1

2 BUTTERFLY VALVES 1. General HyrdoWer is a globally recognized manufacturer of power unit accessories. They have become specialists in the design of Butterfly Valves and Hydraulic Compensators. The shut off valve is installed into the pump suction line. The valve has a SAE (4 - bolt flange) connection, SAE standard J518. The valve can be actuated with or without the shift handle (option H) and the locking bolt will automatically snap the valve into the open or closed position. The optional tank flange (T-option) can be welded to the reservior, giving a bolting surface for the butterfly valve. A limit switch (E-option) can be mounted to the top of the valve. Explosion-proof limit switches are available. 2. Technical Data: Operating Pressures: Maximum pressure: 232 p.s.i. Negative pressure: 10 p.s.i. Pressure difference: 58 p.s.i. (per side when valve is closed) Material: Body + Shift Handle : Seals: Other Parts: 3. Ordering Code: Aluminum NBR Steel Galvanized A B 1 6 S [ N G ] - T H B E Additional description Basic equipment item #4 Limit-switch (see option #8) 4. Butterfly Valve: AB 16 [NG] Pump side Tank side Pump side Tapped bushings (see option #7) Shifter (see option #6) Tank welded (see option #5) Mounting, screws and O-Ring is supplied with valve. Type [NG] Size A B D C E F G H J K L M N O SW O-Ring SAE (in) (in) (in) (in) (mm) (mm) (in) (in) (in) (in) (in) (mm) (in) (mm) (mm) (mm) AB 16 S /4" M M x3.5 AB 16 S /2" M M X3.5 AB 16 S 50 2" M M X3.5 AB 16 S /2" M M X4 AB 16 S 80 3" M M X4 AB 16 S 100 4" M M X4 AB 16 S 125 5" M M X4-2-

3 BUTTERFLY VALVES Tank side Pump side 5. Flange - Option T : The flange can be welded to the reservoir, giving a bolting surface for the butterfly valve. Type [NG] Size ØD1 ØN1 ØO1 ØP Q Q1 R SAE (in) (in) (in) (in) (in) (in) (in) AB 16 S /4" AB 16 S /2" AB 16 S 50 2" AB 16 S /2" AB 16 S 80 3" AB 16 S 100 4" AB 16 S 125 5" Tank side Pump side 6. Shift Handle Option H : 90 to shut Type W X (in) (in) AB 16 S 32 to AB 16 S 63 to Threaded Adapter Bushing Inserts - Option B Threaded busing that adapts to standard SAE tapped holes. With these bushings, it will accept the screws provided with Butterfly valve. Threaded bushing Type E L1 SW1 UNC-2B in mm AB 16 S 32 to 63 7/ AB 16 S 40 to 63 1/ AB 16 S 80 to 125 5/ Limit switch - option E Wiring diagram when Butterfly valve is closed Type E L1 SW1 UNC-2B (in) (mm) AB 16 S 32 to 63 7/ AB 16 S 80 to 125 5/ to to -3-

4 COMPENSATORS 1" - 4" 1. General: The HydroWer Rubber Compensators is a product that qualifies as one of the best kept secrets of power unit accessories. The Hydrower Rubber Compensators are flexible connectors with SAE-flanges. The oscillation compensators are used for damping of oscillators and vibrations, noises and movements in axial and transversal direction. The HydroWer Compensator is constructed of an inner liner of a reinforced high strength rubber (Nitrilcaoutchouc. Perbunan). The outer and inside layers are smooth and have an aerodynamic design that eliminates cavitation. The outside rubber (neoprene caoutchouc) is weather resistant. Both ends of the Compensators have vulcanized sealing lips. With the vulcanized sealing lips on each end, additional seals are not necessary Pump Typical Installation: 1 - Tank wall 2 - Flange 3 - Butterfly Valve 4 - Compensator Tank Pump 2. Technical Data: Working Pressure: 87 p.s.i. Max. Pressure: 174 p.s.i. Burst Pressure: 290 p.s.i. Vacuum: 20" Hg Temperature -4 F to 176 F Tank Acceptable Movement For Acceptable Movements See Tables 1, 2, 3, 4-4-

5 COMPENSATORS Compensator with SAE to SAE Flange connecting sizes after SAE-Standard J 518c sealing surface with sealing lips Size Table 1 Type [NG] Size A B D E F G H L Acceptable Movement SAE (in) (in) (in) (in) (in) (in) (in) (in) Push/Pull Offset Angle( ) Weight (lbs.) K 16 S 25 1" ±0.20 in ±0.20 in K 16 S /4" ±0.20 in ±0.20 in K 16 S /2" ±0.39 in ±0.39 in K 16 S 50 2" ±0.39 in ±0.39 in K 16 S /2" ±0.39 in ±0.39 in K 16 S 80 3" ±0.39 in ±0.39 in K 16 S /2" ±0.39 in ±0.39 in K 16 S 100 4" ±0.39 in ±0.39 in Compensator with SAE to DIN-Flange SAE-Flange DIN-Flange sealing surface with sealing lips connecting sizes after SAE-Norm (J 518ci) and after DIN ND 16 Table 2 Type [NG] Size A B C D E F G H K L M N Acceptable Movement SAE (in) (in) (in) (in) (in) (in) (in) (in) (in) (in) (mm) (in) Push/Pull Offset Angle ( ) Weight (lbs.) K16SD- 25 1" x ±0.20 in ±0.20 in K16SD /4" x ±0.20 in ±0.20 in K16SD /2" x ±0.39 in ±0.39 in K16SD- 50 2" x ±0.39 in ±0.39 in K16SD /2" x ±0.39 in ±0.39 in K16SD- 80 3" x ±0.39 in ±0.39 in K16SD /2" x ±0.39 in ±0.39 in K16SD " x ±0.39 in ±0.39 in

6 COMPENSATORS Compensator with NPT Thread to NPT Thread Table 3 Type [NG] NG L R SW1 SW2 Acceptable Movement (in) (in) (NPT) (mm) (mm) Push/Pull Offset Angle( ) Weight (lbs.) K 16 R " ±0.20 in ±0.20 in K 16 R /4" ±0.20 in ±0.20 in K 16 R /2" ±0.39 in ±0.39 in K 16 R " ±0.39 in ±0.39 in Check when installing When installing the compensator, it must be in line and maintain the dimension "L" length. For compensators with NPT pipe thread the nut SW2 must only be hand tight. The movement absorption in static and dynamic loads and the different types of movements must be added together and the totals are not allowed to exceed the data given. Attention: Pressure spikes are push loads which add to the axial movement. Do not exceed given data! Compensator with SAE-Flange to NPT Thread sealing surface with sealing lips Flange connecting after SAE-Norm J NPT Pipe Thread Table 4 Type [NG] Size A B D E F G H L R SW1 SW2 Acceptable Movement SAE (in) (in) (in) (in) (in) (in) (in) (in) (in) (mm) (mm) Push/Pull Offset Angle ( ) Weight (lbs.) K16SR- 25 1" " ±0.20 in ±0.20 in K16SR /4" /4" ±0.20 in ±0.20 in K16SR /2" /2" ±0.39 in ±0.39 in K16SR- 50 2" " ±0.39 in ±0.39 in

7 SCREW-IN TYPE CHECK VALVES Ball Type Poppet Design - patent pending Pressures to 10,000 psi (700 bar) - Flows to 23 gpm (90 l/min) Nominal Size: 1/16-1/8-1/4-3/8-1/2-3/4 Threads: BSP, Metric, and Inch sizes on request Type: RVA Type: RVB Type Max G L I b zxød 0-Ring Curve # GPM (90 sh) RVA 2-M 0.79 M x x1 1 RVA 3-M 1.59 M8x x1.6 4x1 2 RVA G 1/8 RVA 4-M 2.64 M 10x x1.8 6x1 3 RVA G 1/4 RVA 6-M 6.61 M 14x x2.2 9x1 4 RVA G 3/8 RVA 8-M M18x x3 11x1.5 5 RVA G 1/2 RVA 10-M M22x x3.8 14x1.5 6 RVA G 3/4 RVA 16-M M27x x x Type Max G L I SW 0-Ring Curve # GPM (90 sh) RVB 2-M 0.53 M x1 8 RVB 3-M 1.06 M8x x1 9 RVB G 1/8 RVB 4-M 2.11 M 10x x1 10 RVB G 1/4 RVB 6-M 4.76 M 14x x1 11 RVB G 3/8 RVB 8-M 7.93 M18x x RVB G 1/2 RVB 10-M M22x x RVB G 3/4 RVB 16-M M27x x Techincal Data: Operating Pressure: 10,150 psi (lock pressure) Proof Pressure: 40,600 psi Temperature Range: -40 F to 176 F Viscosity Range: 5 to 500 c St Installation Position: Any direction Flow Rate: See section 4 Stainless Steel on Request It is absolutely necessary to maintain the "x" dimension of the cavity (item #5) Type G K d T U X RVA +RVB 2 M RVA +RVB 3 M8x RVA +RVB 4 G 1/8 8.7 RVA +RVB 4 M 10x RVA +RVB 6 G 1/ RVA +RVB 6 M 14x RVA +RVB 8 G 3/ RVA +RVB 8 M18x RVA +RVB 10 G 1/2 19 RVA +RVB 10 M22x RVA +RVB 16 G 3/ RVA +RVB 16 M27x X - Thread run-out. It can be smaller, but not larger. T - Minimum depth without plug, thread joint, transverse drill and so on. In case of stronger impacts and vibration, it is recommended to secure the valves with loctite or similar. *All dimensions in mm. Oil viscosity measured at 50 cst. Warning: In case of sudden loading of the check-valve in flow direction, for example behind tank or hoses, the specified flow quantity must not be exceeded. -7-

8

Diaphragm Accumulators

Diaphragm Accumulators 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydro-pneumatic accumulators for storing fluids.

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features

More information

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998 Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

Material Handling Hose

Material Handling Hose Novaflex 5000 Slurry King Hose Pure Gum Liner Tough, versatile alternative to inflexible, cumbersome steel tubing. The easy handling and reusable quick-fastening flange system make installation a snap.

More information

AIR AND VACUUM VALVES

AIR AND VACUUM VALVES MINING DIVISION AIR AND VACUUM VALVES FOR HIGH FLOW K-6NS SERIES DESCRIPTION The K-6NS Series Air and Vacuum Valve discharges air during the filling or charging of the system and admits air into the system

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm Return Filters E E Tank top mounting Connection up to G¼ / - SE up to l/min / 8. gpm Description pplication In the return line circuits of hydraulic systems. erformance features rotection against wear:

More information

Hydraulic Accumulators with Back-Up Nitrogen Bottles

Hydraulic Accumulators with Back-Up Nitrogen Bottles Hydraulic Accumulators with Back-Up Nitrogen Bottles 1. GENERAL To complete the accumulator range, HYDAC provides a variety of useful accessory products. They guarantee correct installation and optimum

More information

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25

More information

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to: LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are

More information

SDM to 8 sections monoblock valve D1WWDA02A

SDM to 8 sections monoblock valve D1WWDA02A SDM 1 SDM1 1 to 8 sections monoblock valve D1WWDA2A SDM1 Additional information This folder shows the product in the most standard configurations. Please contact Sales Dpt. for more detailed information

More information

WaterSource Heat Pump Hose Kit Performance Specification-Summary

WaterSource Heat Pump Hose Kit Performance Specification-Summary WaterSource Heat Pump Hose Kit Performance Specification-Summary AUTOMATIC & MANUAL BALANCING HOSE KITS Contractor shall provide and install Hays Hose Kits. Each kit, shall include a Hays 2500 Series Mesurflo

More information

TA-FUSION-P. NPT threads / ANSI flanges

TA-FUSION-P. NPT threads / ANSI flanges TA-FUSION-P NPT threads / ANSI flanges Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics IMI TA / Control valves / TA-FUSION-P

More information

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow

More information

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked

More information

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 PO Box 411 Berwick PA 18603 800-247-VALV www.crispinvalve.com 500 SERIES: Sizes 3-20 Available The K-Flo 500 Series is a heavy-duty resilient seated butterfly

More information

STAD-C. Balancing valves DN 15-50

STAD-C. Balancing valves DN 15-50 STAD-C Balancing valves 15-50 IMI TA / Balancing valves / STAD-C STAD-C The STAD-C balancing valve has been specially developed for use in indirect cooling systems but performs just as effectively in refrigerated

More information

pipe connectors. General description of pipe connectors Development/Design Purpose Versions

pipe connectors. General description of pipe connectors Development/Design Purpose Versions Pipe connectors General description of pipe connectors 1 STFLEX pipe connectors, just like STFLEX rubber expansion joints, have been used for more than years as the preferred connection elements in appliance

More information

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5 operating Instructions manual MUELLER Mega-Lite Drilling Machine table of contents PAGE Equipment 2 Operating Instructions 3-4 Parts Information 5 Travel Charts 6-11! WARNING: 1. Read and follow instructions

More information

Spin-On Filters SSF 24,25

Spin-On Filters SSF 24,25 Spin-On Filters SSF,5 Technical Specification Construction Die cast aluminium head Seals NBR (Buna-N ) Port connections Flow rate Working pressure Operating temperature By-pass valve Clogging indicators

More information

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 2300 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit

More information

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X Calibration Hydraulic comparison test pump Models CPP1000-X, CPP1600-X WIKA data sheet CT 91.12 for further approvals see page 2 Applications Calibration service companies and service industry Maintenance

More information

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI Jetstream offers a wide variety of fittings with various connection types to fit your 20,000 psi application needs. The standard connection types, Type M, MP, and MP Tube lance, are available in standard

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

SEALED CONNECTORS FOR THE LIMIT SWITCHES

SEALED CONNECTORS FOR THE LIMIT SWITCHES SEALED CONNECTORS FOR THE LIMIT SWITCHES LIST OF MODELS / Sealed connectors are used at the cable-connecting section of limit switches. Type and appearance Materials Features Target market Applications

More information

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface ywire Elements Element 4/3 with side ports IW5 Interface efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES 398SW5EN - 5--8 Technical data Nominal flow 5 l/min 3. US

More information

Pressure transmitters EMP 2

Pressure transmitters EMP 2 Data sheet Pressure transmitters EMP 2 The high accuracy pressure transmitter EMP 2 is designed for monitoring and control in marine and industial applications and offers a reliable pressure measurement,

More information

3-Way Safety Block DSV

3-Way Safety Block DSV 3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with

More information

Diaphragm Accumulators

Diaphragm Accumulators Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in HYDAC diaphragm accumulators

More information

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet Gas powered stop valves, type GPLX 80-150 REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical leaflet Gas powered stop valves, type GPLX 80-150 Contents Page Introduction........................................................................................3

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 33100 and 33101 Hydrostatic Test Pumps 33100 DIMENSIONS: WEIGHT: PUMP: MOTOR: CONTROL: GAUGE: DISCHARGE HOSE: 16 (40cm) L x 22 (55cm) W x 18 (45cm) H 87 lbs., 39.5 kg Triplex

More information

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

SV - Safety Shutoff Valve with Proof of Closure 1/2 NPT - 2 NPT. SV/614 Series SV-DLE/614 Series SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT SV/614 Series SV-DLE/614 Series Normally closed automatic shutoff valve with proof of closure and the following approvals. CSA Certified

More information

shutoff valves 900 Series psig Manual Shutoff Valves

shutoff valves 900 Series psig Manual Shutoff Valves 0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on

More information

Hydraulic hand test pump Models CPP700-H and CPP1000-H

Hydraulic hand test pump Models CPP700-H and CPP1000-H Calibration technology Hydraulic hand test pump Models CPP700-H and CPP1000-H WIKA data sheet CT 91.07 for further approvals see page 2 Applications Simple test pressure generation on site, in the laboratory

More information

Pressure Reducing Valve DMV 755

Pressure Reducing Valve DMV 755 Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to

More information

1000/13.02 KOBSERT. Thread inserts for metals

1000/13.02 KOBSERT. Thread inserts for metals 1000/13.02 KOBSERT Thread inserts for metals Contents KOBSERT Thread inserts for metals Page The principle 3 The benefits 3 Product types 3 Applications in the Automotive and General industry 4 Technical

More information

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level

More information

HYDRAULIC CONTROL VALVES

HYDRAULIC CONTROL VALVES HYDRAULIC CONTROL VALVES INC. VALVES, INC HYDRAULIC CONTROL VALVES WORKING PRINCIPALS It is automatic hydraulic control valve designed for make desired modulation processes in main valve network line as

More information

Controllers DR, DP, FR and DFR

Controllers DR, DP, FR and DFR Controllers DR, DP, FR and DFR RE 9060 Edition: 04.014 Replaces: 10.006 For variable pump A4VSO series 1 and 3 Open circuit Features Control of pressure and flow Remote controlled optional Pressure controller

More information

Homestead Series 820 AWWA Butterfly Valves

Homestead Series 820 AWWA Butterfly Valves Homestead Series 820 AWWA Butterfly Valves Dependable Valves for Water & Wastewater Service BODY: The ductile iron body meets or exceeds the design strength requirements of the AWWA C504 standards. Flange

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow

More information

FILTER TYPE PRESSURE SNUBBER

FILTER TYPE PRESSURE SNUBBER FILTER TYPE PRESSURE SNUBBER Pressure oscillations and other sudden pressure changes can affect the delicate mechanisms of a pressure gauge or pressure transmitter. This can result in either complete failure

More information

Unit 1, Fullerton Road Rotherham S60 1DJ. Tele: Fax:

Unit 1, Fullerton Road Rotherham S60 1DJ. Tele: Fax: Unit 1, Fullerton Road Rotherham S60 1DJ Tele: 0845 601 333 6 Fax: 0845 601 333 7 info@fabricatedproducts.co.uk www.fabricatedproducts.co.uk Data Sheet 6.0 Rubber Pump Flexes All rubber bellows are suitable

More information

STAD. Balancing valves DN (MD60, MD61, MD62)

STAD. Balancing valves DN (MD60, MD61, MD62) STAD Balancing valves DN 15-50 (MD60, MD61, MD62) IMI TA / Balancing valves / STAD STAD The STAD balancing valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited

More information

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2 Self-operated Pressure Regulator Pressure Reducing Valve Type M 44-2 Type M 44-2, connection G 1 4, K VS = 0.15 Type M 44-2, connection G 1, K VS = 6 Fig. 1 Type M 44-2 Pressure Reducing Valve Mounting

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

Pressure relief valves

Pressure relief valves Pressure relief valves Type DV700 Features Direct operated valve High degree of pressure stability Safe operation Precise pressure adjustment Maximum pressure setting with lock nut Applications as cartridge

More information

Pressure Relief Valves. SPV, SPVF direct operated

Pressure Relief Valves. SPV, SPVF direct operated Pressure Relief Valves SPV, SPVF direct operated Construction P Ø d 1 a T c 2 3 b 4 1 Housing 2 Sliding piston 3 Compression spring 4 Set screw Bleeding screw 6 Protective cap 6 Description The pressure

More information

STAD. Balancing valves DN 15-50

STAD. Balancing valves DN 15-50 STAD Balancing valves DN 15-50 IMI TA / Balancing valves / STAD STAD The STAD balancing valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited for use on the

More information

SATURNSERIES INTERCHANGE > ISO (for the couplings)

SATURNSERIES INTERCHANGE > ISO (for the couplings) Saturn Block INTERCHANGE > ISO 16028 (for the couplings) PATENTED ISO 16028 TECHNICAL FEATURES AND OPTIONS Interchange ISO 16028 (for the couplings) Sealing description Nitrile NBR Connection system Push

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

directional control valve series cv691

directional control valve series cv691 directional control valve series cv691 Contents Page 3 Page 4 Page 5 Page 6-7 Page 8 Page 9 Page 10 Page 11-12 General Information Technical Data Performance Curves Dimensions Relief Valve Advantages

More information

Booster Regulator/Air Tank

Booster Regulator/Air Tank Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed

More information

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper LOG Cost effective. Smooth. Reliable. LOG Internal Hole Gripper Light gripper made of very resistant polyamide with closed diaphragm system Field of Application Particularly suited to highly dynamic applications

More information

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics TA-FUSION-P Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics IMI TA / Control valves / TA-FUSION-P TA-FUSION-P These innovative

More information

Schroeder Check Test Point System

Schroeder Check Test Point System Perforated polyamide / kevlar hose, 2 mm ID, 5 mm OD, plastic dust cap. L in (mm) P (max) psi (bar) 6 (150) 10,000 (680) 12 (300) 10,000 (680) 24 (610) 10,000 (680) 36 (915) 10,000 (680) 48 (1220) 10,000

More information

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design. http://www.pisco.co.jp VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Three-way Changeover Valve Change Valve Changeover Air Direction by 90 Lightweight and Compact Design. Fine Operability and

More information

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

INSTRUCTION MANUAL Pressure Relief Device LPT

INSTRUCTION MANUAL Pressure Relief Device LPT INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF

More information

Pressure reducing valve, pilot operated, Model 3DR

Pressure reducing valve, pilot operated, Model 3DR RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features

More information

NEW TYPE M PRESSURE RELIEF DEVICE

NEW TYPE M PRESSURE RELIEF DEVICE NEW TYPE M PRESSURE RELIEF DEVICE M PRESSURE RELIEF DEVICE ACCORDING TO EN 50216-5/A2 PATENTED 2 PRESSURE RELIEF DEVICE TYPE 50 M Section A-A 170 139 Transformer tank F 41.5 3 ø48.3 ø166 A P.R.D. TAG A

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US Industrial Hydraulic Valves Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories Catalog HY14-2500/US Industrial Hydraulic Valves WARNING USR RSPONSIBILITY FAILUR OR IMPROPR

More information

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm) Vickers Cartridge Valves Load Controls Screw In Cartridge Valves Pressures to 50 bar (5000 psi) Flows to 90 l/min (50 USgpm) Rev. 2/99 722 Contents MODEL DESCRIPTION TYP. APPLICATION PRESSURE bar (psi)

More information

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads TBV-CM Combined control & balancing valves for small terminal units For modulating control NPT threads IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling

More information

Leak-Free Load-Control Valve SAE ½ psi flange

Leak-Free Load-Control Valve SAE ½ psi flange Leak-Free Load-Control Valve SE ½ - 6000 psi flange Q max = 150 l/min [40 gpm], p max = 420 bar [6000 psi] leak-proof, two-stage hydraulic, SE-flange design 12--S... 1 Description Two-stage load-control

More information

FITTING IDENTIFICATION AMERICANT THREAD TYPES APPENDIX ALFAGOMMA // APPENDIX. Dash numers. NPTF (National Pipe Tapered Fuel)

FITTING IDENTIFICATION AMERICANT THREAD TYPES APPENDIX ALFAGOMMA // APPENDIX. Dash numers. NPTF (National Pipe Tapered Fuel) // FITTINGS GUIDelines FITTING IDENTIFICATION numers Most fluid piping system sizes are measured by dash numbers. These are universally used abbreviations for the size of component expressed as the numerator

More information

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE MAKING MODERN LIVING POSSIBLE Data sheet Water valve Type WVO Water valve type WVO is used for regulating the flow of water in refrigeration plant with water-cooled condensers. The water valve gives modulating

More information

Change-Over Pressure Filter DFDK

Change-Over Pressure Filter DFDK Change-Over Pressure Filter up to 8 l/min, up to 35 bar 3 6 4 6 4 8 33 5 66.x 66.x 99.x 3.x 3 3.x 64 3.x 396 3.x. TECHNICAL SPECIFICATIONS. FILTER HOUSING Construction The filter housings are designed

More information

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d R e t u r n - S u c t i o n F i l t e rs E 158 E 198 E 248 Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min 20.90-5e 0.0-2d D e s c r i p t i o n Application For operation in

More information

Pressure Sensing Valve - Model 4023

Pressure Sensing Valve - Model 4023 Pressure Sensing Valve - Model 4023 Overview AMOT Model 4023 can be used as a 2 or 3-way capacity, pressure sensing valve. This valve is ideal for applications that require compressor suction and discharge

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV Safety and Shut-off Block SAF/DSV 1.1.1 Key to the circuit diagram Circuit diagram The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies

More information

DAV - WP DAV - WP. Wastewater Air Valves. Product Catalogue. (Wastewater Air Valves) DAV - WP

DAV - WP DAV - WP. Wastewater Air Valves. Product Catalogue. (Wastewater Air Valves) DAV - WP DAV - WP Wastewater Air Valves DAV - WP (Wastewater Air Valves) Product Catalogue DAV - WP DAV Series??? DAV-WP General DAV-WP Wastewater Air Valves The DAV-WP valve has been designed for efficient discharge

More information

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump

More information

PVQ 13 A2 R SE 1 S 20 C-11 D

PVQ 13 A2 R SE 1 S 20 C-11 D PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard

More information

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

BIMBAR INFLATABLE PACKERS AND ACCESSORIES BIMBAR INFLATABLE PACKERS AND ACCESSORIES Geopro supplies a complete range of inflatable packers in nine different diameters from 28 up to 170mm. All our packers made of BIMBAR rubber technology are reinforced

More information

Proportional Throttle Cartridges, Size 16

Proportional Throttle Cartridges, Size 16 Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact

More information

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS COMPACT TRIPLE WALL OUTLET STATION MODEL 6255-1 INSTALLATION AND OPERATING INSTRUCTIONS To assure safe operation and conformation to local fire codes, all Porter Outlet Stations are designed to be used

More information

Aquor House Hydrant V2

Aquor House Hydrant V2 Aquor House Hydrant V2 IN-WALL OUTDOOR FAUCET SYSTEM FLUSH-MOUNT QUICK-CONNECT SELF-DRAINING ANTI-SIPHON NON-FREEZE VBH-SERIES AQUOR HOUSE HYDRANT V2: WALL HYDRANT / FREEZELESS SILLCOCK Freezeless sillcock

More information

K0709 Quick-fit couplings

K0709 Quick-fit couplings Joints 1067 K0709 Quick-fit couplings with radial offset compensation external thread D1 SW SW1 application example: X max. D D 3 4 internal thread SW 3 4 2 SW1 D D Coupling part and claw in steel. Nut

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

CASH VALVE TYPE KP BACK PRESSURE VALVES

CASH VALVE TYPE KP BACK PRESSURE VALVES A high capacity pilot operated back pressure valve that offers accurate control and dependable protection against overpressure conditions FEATURES Automatically maintains maximum pressure in a vessel or

More information

Gas Welding Hoses and connections, the weak link

Gas Welding Hoses and connections, the weak link Gas Welding Hoses and connections, the weak link By Leif Andersen, Technical Product Manager Welding, WSS Regulators with flashback arrestors and the shank with its welding or cutting attachment are made

More information

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS OPERATION MANUAL 2 METALLIC PUMP (BOLTED) PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF50 AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company CAUTIONS - READ FIRST CAUTION:

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or user units. It complies with the relevant safety standards in accordance with

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential

More information

Two-stage valve type NE

Two-stage valve type NE Two-stage valve type NE Product documentation Operating pressure pmax: Flow rate Qmax: 700 bar (High pressure) 80 bar (Low pressure) 25 lpm (High pressure) 180 lpm (Low pressure) D 7161 03-2017-1.0 by

More information

Technifit. Union Bulkhead Flow Controller. Fractional & Metric. Push-to-Connect Fittings. March 2006

Technifit. Union Bulkhead Flow Controller. Fractional & Metric. Push-to-Connect Fittings. March 2006 Technifit TM Push-to-Connect Fittings March 2006 Male Female Elbow Tee Union Bulkhead Flow Controller Fractional & Metric PO Box 335 12740 State Route 4 Milford Center, Ohio 43045-0335 USA Phone: 937.349.4055

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

Double Pilot Operated Cartridge Check Valve, Size 8

Double Pilot Operated Cartridge Check Valve, Size 8 Double Pilot Operated Cartridge Check Valve, Size 8 Q max = 7 l/min (19 gpm), p max = 35 bar (5 psi) pilot operated, two-stage, spring-closed cartridge-type poppet valve Compact design for cavity type

More information

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 11, 005 GAS009R1 VGG VGD0 VGD0 Description Only when assembled to SKP

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

VAREC 180 SERIES PRESSURE REGULATORS

VAREC 180 SERIES PRESSURE REGULATORS Double port regulators with a variety of model options for upstream and downstream pressure control FETURES Large diaphragm and a unique double port design achieve a sensitivity of less than 5%. Set pressure

More information

Directional Controls

Directional Controls Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP

More information

S300 Series. Valve Link. Features. Fisher Controls

S300 Series. Valve Link. Features. Fisher Controls S0 Series Self-Operated Type VL FIELDVUE Regulators Valve Link Fisher Controls May 198 Bulletin 71.1:S0 The S0 Series self-operated, spring-loaded regulators are used for pressure-reducing control in a

More information

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version Application Excess pressure valve for set points from 0.075 to 150 psi (5 mbar to 10 bar) Valve size NPS ½ to 2

More information

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Type N-10, N-11 Hazardous Area Non-incendive Transmitters Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial

More information