RegO Adapters, Connector, & Fittings
|
|
- Stuart Horton
- 6 years ago
- Views:
Transcription
1 RegO dapters, onnector, & Fittings Extended Type ouplings for Vapor and Liquid Service esigned especially for liquid filling and vapor equalization of LP-Gas and anhydrous ammonia. The limited travel of the handle on the tailpiece minimizes spin-off, encouraging cautious removal to properly bleed off trapped product to assure closure of the filler valve and hose end valve. The ME threads are machined on a rugged steel insert which is permanently cast in the aluminum handle, providing for durability under repeated use. Type of Service onnection (M. NPT) L2* L Liquid L4 " L** L Vapor L * Includes 99- adapter, shipped loose. ** Includes L- adapter, shipped loose. oupling onnection (F. ME) pprox. Length " Series Series Short Type ouplings for Vapor and Liquid Service Style For Liquid Filling Style For Liquid Filling Style For Vapor Equalizing Style For Vapor Equalizing Style rass onnection (M. NPT) oupling onnection (F. ME) Tailpiece ore 64" End To Nut Overall Length 2" 2 " 8 2 6" 2 6" 9 rass Nut & Steel Nipple 2" 6" 2 2" 2 " Steel 8 2 6" 2 9 2" 6" 2 6" 2 6" 8 rass 6" 2" 8 " 6" 9 2 6" 2 6" ME Wrench # escription J Wrench For ME Wrench I2 For ME Wrench I2 J Wrench 80
2 RegO dapters, onnector, & Fittings ME heck onnectors for Lift Trucks These brass connectors are especially designed to join the carburetor fuel line to the service valve on lift truck cylinders. Sturdy, long lasting ME threads allow quick, hand-tight assembly that provides for quick and simple cylinder replacement. ack checks automatically close in each connector when disconnected. The 4M couples directly to the service valve. n integral O-ring is designed to seal before the internal check opens, aiding in product loss prevention. gasket at the ME thread is a secondary seal when the connectors are tightened together. The connector fits RegO lift truck cylinder filling adapters for fast, convenient filling. The 4F accepts fuel line adapter and couples directly to the 4M. The O-ring seal in the 4M is designed to seal before the internal check opens to allow product to pass through the connection. The knurled coupling eases threading and the ME threads provide rapid effortless make-up, even against LP-Gas pressure. 4M 4F pplication Inlet Outlet 4M 4F Service Valve Fuel Line F. NPT F. ME M. ME F. NPT *Recommended to minimize foreign material entering valves which could result in leakage. ** See page 82 for size chart. Protective ap* Rubber rass 4M-40 4FP Repair s** Gasket 4M-R (2 Per Pkg) O-Ring -2 Unloading dapters for ontainer Evacuation esigned to provide an efficient means of evacuating an LP-Gas container for relocation or repair. They thread directly onto the ME male hose connection of RegO Filler Valves used on RegO ouble heck Filler Valves and Multivalves. The unloading adapters can be used to withdraw liquid provided the container is equipped with a dip pipe extending from the filler valve to the bottom of the container Style In-Line ngle Filler Valve onnection F. ME onnection M. ME F. NPT Filler dapters These adapters are designed with minimal flow restriction and recommended for use on the outlet of the LP-Gas delivery truck filler hose. If the controlled bleed off of the connection indicates the filler valve on the tank being filled has failed to close, the hose adapter should be left in place on the filler valve and disconnection should be made at the regular filler hose coupling. (Repair of the filler valve must be made as soon as possible). n integral check valve in these adapters helps prevent further loss of product. The standard filler valve cap should be attached to these adapters when left on the container. 9 uilt-in Vent Valve Filler Valve onnection onnection V V 9 Yes No F. ME M. ME 8
3 RegO dapters, onnector, & Fittings End dapters for OT ylinder Filling esigned to provide quick and easy filling of OT cylinders with POL or Type I connections. This adapter may be used with hydraulic and electric automatic systems or with manual systems in conjunction with a RegO 90T Quick cting Shut-Off Valve. These filling connectors have an extended connection on the handwheel, which makes it possible to connect the loading hose to valves on cylinders with fixed collars. The handwheel is well outside the collar for easy operation. 9-0 pplication Inlet onnection Outlet onnection s 9-0 9U-0 Filling of OT ylinders with POL onnections Filling of OT ylinders with Type I onnections M. NPT M. POL (G 0) Type I onnection ( 6 M. ME) rass and Stainless Steel rass 9U-0 onnector for OT ylinder Filling dapter The 9T-0 is designed for use on the 9-0 Filling dapters. onnector allows adapter to be used on the 6 M. ME & F. POL connections of Type valves. pplication Inlet onnection Outlet onnection s 9T-0 onverts 9-0 dapter from POL to a Type onnection M. POL G 0 Type onnection ( 6" M. ME) rass 9T-0 End dapter for Lift Truck ylinder Filling The 9L-0 is designed to provide quick and easy attachment of the filling hose to OT cylinders equipped with RegO 4M check connectors. 9L-0 pplication Filling of Fork Lift ylinders* Inlet onnection Outlet onnection ody ccessories dapter M. NPT F. ME rass 60 * The 9L-0 is intended to be permanently attached to the filling hose. 60 adapter enables the 9L-0 to be attached to the POL connection on the 9-0 at regulator cylinder filling stations to allow for occasional filling of fork lift cylinders. Lever Operated End dapter for Fork Lift ylinder Filling esigned to drastically reduce labor and time when continuously filling large numbers of lift truck cylinders equipped with RegO 4M check connectors. pplication Inlet onnection Outlet onnection s 9K-0 Lever Operated for Quick Filling of Fork Lift ylinders F. NPT Quick isconnect Yoke* rass and Steel * For use with RegO 4M check connector. 82
4 RegO dapters, onnector, & Fittings ME Plugs Specifically designed to withstand the everyday abuse given hose end valves on delivery trucks and hose end couplings on risers in bulk plants. These rugged plugs protect the coupling tip as well as prevent the entrance of dirt, dust, snow and rain. They also prevent possible gas contamination from these same sources. The heavily ribbed outer surface permits hand-tight make-up. (M. ME) 6N 6N 6PR Nylon rass hain & Ring Fits Pipe Size Up To: 6N 2 Nylon 69N 2" Not pplicable POL Plugs Highly recommended for installation in LP-Gas cylinder valve POL outlets whenever the service line is disconnected or when the cylinder is being transported. When properly installed, the POL plug is designed to prevent contamination of the valve outlet and guards against product leakage if the cylinder valve is accidentally opened. 90EZP 0R W/hain & Ring onnection 90EZP 08P 0R Plastic rass M. POL (G 0) aps and Reducers 08P (Has hole for attaching wire to prevent loss of plug) 44-9 Plastic ap Metal ap 6 Reducer oupling ap With hain & Ring Ring Fits Pipe Size Up To: ap Only P 4-9 ycolac 4-9P P Nylon 08 Thread onnection F. ME F. ME F. POL (G 0) 4FP F. ME P F. ME rass " 2 F. ME " * F. ME " 2 F. ME " Steel F. ME 6* * Reduces to M. ME 4FP ap Plug 08 POL ap G 0 P ap Plug 8
5 RegO dapters, onnector, & Fittings Washers (ctual Size) # Use Size 4M-R Fork Lift onn. ME R ME 29-20R Filter, Vapor Valve & dapter ME 84-8R onnections 2 ME 94-8R ME 4M-R 29-20R R 84-8R 94-8R una-n O-Rings (ctual Size) # Use 9- POL Nipple Size POL -2 Internal Fork Lift ME 84-20R Filler, Vapor Valve 2 ME 94-20R & dapter onnections ME R 94-20R 84
6 RegO dapters, onnector, & Fittings ME dapters 64 M. ME F. NPT E " rass 66E " 2 66F 68G 68H 2" 68J E Steel " E iameter For Spare Gasket Order No R 2 2 6" 84-8R R 2 6" R 68H 2" 6" 94-8R Gasket (Furnished with adapter) E ME x Female NPT M. ME M. NPT E iameter For Spare Gasket Order No. 6 6" 29-20R 6 6" 6E " R 2 6F 6F rass " 6" 6G 84-8R 6H 2" 2 2 6" 2 64" 69H 2" 2 69J R 2 69K " 6 6 6" 2 6" 6E " R 6F Steel 6" 6F " 84-8R 69H 2" 2 69K " 6" R E Gasket (Furnished with adapter) ME x Male NPT 6M M. ME iameter For Spare Gasket Order No. 2 6" R 6M rass " 2 64" 84-8R 69M R Gasket (Furnished with adapter) ME x ME M. ME Thread For Spare Gasket Order No. 64W Steel * 6" * -6 UN Thread. ME x Miscellaneous (Recommended for securing hose-end valve when not in use). 8
7 RegO dapters, onnector, & Fittings Male POL Swivel dapters 90U (G 0) POL Hard Nose POL 90S (G 0) POL Soft Nose POL w/60 MS Orifice 90XS (G 0) POL Soft Nose POL w/excess Flow 0-0 Micron Filter 99W (G 0) POL Heavy uty Hard Nose POL w/excess Flow 90X (G 0) POL Hard Nose POL w/excess Flow 90W (G 0) POL 90HT Soft Nose POL w/handwheel (G 0) POL 90JR Hard Nose POL w/ arb onnection losing Flow (Propane) rill Liquid (GPM) 90U 6" 2 90S 6" 2 90X 2 64" XS M. NPT 6" 99W rass 2 6" W 2 90HT 6" 90JR arb Note: ll nipples incorporate wrench hex section. 2 Vapor at 00 PSIG Inlet (SFH) G Swivel dapters G rass M. NPT 9 6"-8NF 6" 6" G 86
8 RegO dapters, onnector, & Fittings POL dapters (G 0) POL Male POL x Female NPT F. NPT " rass 2906G 2" F 2906E rass (G 0) POL Male POL x Male NPT and SE Flare M. NPT SE Flare SE Flare 2 6" 2 6" iameter 9 G 0 (POL) G 0 (POL) Female POL x Male NPT Female POL x Female NPT and Female POL 60Z F. NPT iameter 6" " 60 rass 4 64" 60 60S dapter For use with fuel gases (LP-Gas, cetylene). POL (G 0) 2 00 rass 9 6"-8NF (L.H.) M. NPT 9 6". M. NPT 6 6 rass rass M. NPT iameter 6" 6" Miscellaneous dapters Female Inverted Flare. Female Inverted Flare x Male NPT Pressure Gauge dapter 2 6". E 494- rass F. NPT F. NPT M. NPT Male Female E F 28-8 UNF -8 UNF 6" 2" rass -6 UNF -6 UNF 6" 2 arb 2-4 UNF -4 UNF 6" 2 F 8
ACME Connectors and Fittings Extended Type Hose Couplings for Vapor and Liquid Service A7571 and A7575 Series
M onnectors and Fittings xtended Type Hose ouplings for Vapor and Liquid Service 7571 and 7575 Series esigned especially for liquid filling and vapor equalization of LP-Gas and anhydrous ammonia. The limited
More informationExcess Flow Valves. General Information. How They Work. An Explanation and Warning. Proper Installation
xcess low Valves General Information RegO xcess low Valves have been designed, developed, and manufactured for a wide variety of industry needs for more than three decades. Throughout the years, those
More information5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS
5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS 23 24 5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS INSPECTING, FILLING AND LABELING SMALL CYLINDERS Pre-fill Visual Check Safely inspecting
More informationLP GAS PRODUCTS HIGH QUALITY GAS PRODUCTS SINCE 1957
LP GAS PRODUCTS HIGH QUALITY GAS PRODUCTS SINCE 1957 Enerco, based in Cleveland Ohio, has been at the forefront of infrared technology since 1957. This market leading technology has allowed Enerco to build
More informationUser Information Sheet 013
User Information Sheet 013 Formerly LPGA Technical Memorandum NO.81 Issue 2 September 2007 ACME threaded couplings 1 INTRODUCTION ACME threaded couplings/end fittings are widely used for LPG transfer operations
More information1200B2 Series Service Regulators. Instruction Manual
00B Series Service Regulators Instruction Manual 00B Series Service Regulators 0 Elster American Meter 00B Series Service Regulators General Information The 00B Series Service Regulators are available
More informationPipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
More informationLARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual
LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual 002694 IntroductIon 8-1-11 Page 1 ForEWord This manual is intended for use with
More informationTriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7
TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7 March 2014 Form FVC097 - Rev03 IMPORTANT: KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER.
More informationSection B Cylinder and Service Valves
LP-Gas & Anhydrous Ammonia Equipment Section Cylinder and Service Valves 1 Limited Warranty and Limitation of Liability LIMITED 10 YEAR WARRANTY AND LIMITATION OF LIAILITY LIMITED 10 YEAR WARRANTY Engineered
More informationFOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM
IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY
More informationInstallation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150
Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150 January 2013 Form FVC 084 - Rev 02 IMPORTANT: KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER. 1.
More informationATD LB PRESSURE BLASTER INSTRUCTION MANUAL
ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off
More information1800C and 1800C-HC Series Service Regulators
1800C and 1800C-HC Series Service Regulators Installation Instructions www.elster-americanmeter.com General Information: The 1800C and 1800C-HC Regulators are available as Full Capacity Internal Relief
More informationPressure Regulator B-95
Pressure Regulator B-95 TYPE B WATER & AIR TYPE B INTERIOR WATER & AIR B SERIES VALVES DESTRIPTION The Cash Valve Series B pressure reducing and regulating valves are single seated, spring loaded, direct
More informationRefrigerant Gases Valves
Refrigerant Gases Valves RUS series Single Outlet Compact Refrigerant Recovery Valves 46 RDU series Diaphragm Packless Multivalves for Refrigerant Gases 47 RBV series Single Outlet Diaphragm Packless Valves
More informationSPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.
2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or
More informationRG1200 Service and Repair Manual
Dive Rite RG 1200 Regulator Service and Repair Manual Page 1 Text and Photography by Pete Nawrocky Copyright ( ) 1999-2000, Lamartek, Inc., dba Dive Rite RG1200 Service and Repair Manual First Stage.........................................
More informationPure Water Power Purification System 4-Stage RODI Operations Manual
Pure Water Power Purification System 4-Stage RODI Operations Manual Flush Valve Lever Quick Disconnect for RO Water Testing Water Supply In Drain Hose Pure Water Out to Waterfed Pole New Machine Setup
More informationIndustrial Compression Style Fittings
Industrial Compression Style Fittings Compression Fittings Compress-lign Fittings rass etric Compression oly-tite Fittings i-uty Fittings arker annifin Corporation Fluid System Connectors Otsego, I Industrial
More information2 in. 18 Gauge Brad Nailer. User manual
8504342 2 in. 18 Gauge Brad Nailer User manual Technical Data Capacity....100pcs Nail length... 15-50mm( 5/8-2 ) Fastener size....18gauge (1.25 1.00mm) Operation pressure 70-110PSI(4.8-7.5bar) Air inlet....1/4
More informationRegulator from 1800 B series
Regulator from 1800 B series Regulator from 1800 B series Measuring of industrial gases frequently requests a precise pressure regulation for the purpose of dosage and proccesing. UNIS FAGAS has two kinds
More informationComplying with NFPA 58 Transfer Area and Bulk Plant Liquid Opening Requirements
May 2005 Complying with NFPA 58 Transfer Area and Bulk Plant Liquid Opening Requirements D450143T012 R www.fisherregulators.com/lp Table of Contents Table of Contents............................................................
More information3/8" Dr. Air Butterfly Impact Wrench
8192106 3/8" Dr. Air Butterfly Impact Wrench Owner s Manual Read and understand all instructions before use. Retain this manual for future reference. Specifications Construction: Polished aluminum and
More informationType S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual
Fisher Controls Instruction Manual Type S301 & S302 Gas Regulators October 1981 Form 5180 WARNING Fisher regulators must be installed, operated, and maintained in accordance with federal, state, and local
More informationINSTRUCTION MANUAL & PARTS
AIR LINE PURIFIERS FOR BREATHING EQUIPMENT AP-C RADEX INSTRUCTION MANUAL & PARTS 01-0-11 introduction CANABLAST BREATHING EQUIPMENT PURIFIER CAN BE USED IN CONBINATION WITH WITH OTHER SAFEGUARDS TO SUPPLY
More informationKJ4000 Operating Instructions & Parts Manual NSN
KJ4000 Operating Instructions & Parts Manual NSN 1025-01-473-7710 Mandus Group Ltd. KJ4000 Operators Manual Date: 3 Jan. 2002 TABLE OF CONTENTS General Safety Instructions...Page 1 Operator Instructions...Page
More informationTECHNICAL DATA. Page 1 of 12
Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control
More informationINDUSTRIAL PRODUCTS. Industrial Products Catalog. Innovative Solutions for Gas Management Systems ENTERPRISES
INDUSTRIAL PRODUCTS ENTERPRISES Industrial Products Catalog Innovative Solutions for Gas Management Systems This catalog provides a comprehensive source of information on Western s line of products used
More informationModel 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual
10-12 Steel Pipe Squeezer Sch. 40 & Sch. 80 Operations Manual 1.0 Introduction This manual is issued as a basic operation manual covering the Regent Model 7989T, Pipe Squeezer and Pump as manufactured
More informationChoosing the right miniature instrument and control valve is a snap
Choosing the right miniature instrument and control valve is a snap INVALCO Micro Valve The Micro Valve is a unique miniature valve offering versatility and rugged construction. Since its introduction
More informationNEW Edge Series Products: OUTFITS and REGULATORS
NEW Edge Series Products: OUTFITS and REGULATORS NOW Including ESS3 Models and More Edge Series Outfits User Friendly Advanced Design Outstanding Flow Performance Unsurpassed Safety www.victoredge.com
More informationPRO-50 Instrument Supply Regulator
Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits
More informationPortable Hydrostatic Pneumatic Test Pump. Procedure Manual
Portable Hydrostatic Pneumatic Test Pump Procedure Manual Dixon Valve & Coupling Company 800 High Street Chestertown, MD 21620 800-355-1991 Fax: 800-283-4966 Specifications Dixon Portable Pneumatic Hydrostatic
More informationPressure Dump Valve Service Kit for Series 2300 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit
More informationIndustrial Compression Style Fittings. Compression Fittings Compress-Align Fittings Brass Metric Compression Poly-Tite Fittings Hi-Duty Fittings
Industrial Compression Style Fittings Compression Fittings Compress-lign Fittings rass etric Compression oly-tite Fittings i-uty Fittings arker annifin Corporation Fluid System Connectors Otsego, I Industrial
More informationCOMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL
COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL SPECIFICATIONS: The CARD series air valves are available in 3 pipe sizes, 1, 2 and 4 NPT or socket. Maximum inlet pressure
More informationGas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.
Gas Lines Technical Manual Sumitomo (SHI) Cryogenics of America, Inc. 1833 Vultee Street Allentown, PA 18103-4783 U.S.A. Revision F: April 2008 261320A TABLE OF CONTENTS Page DESCRIPTION...1 SPECIFICATIONS...2
More informationV-24 OXYGEN LANCE VALVE
INSTRUCTIONS for F-4737-U May, 2009 V-24 OXYGEN LANCE VALVE w/ C -Size Inlet w/ B -Size Inlet V-24 Oxygen Lance with 1/8" Pipe Holder... 9728D65... 2218939 V-24 Oxygen Lance with 1/4" Pipe Holder... 9728A65...
More informationDescription Supply pressure Pressure range Connection Device Page max. bar bar thread
Pressure Regulators Supply pressure Pressure range onnection Device Page max. bar bar thread Maxi -Series, robust, interlockable 1 0. 1.8 / 17 G¼ - G1 R0, R1.0 made of plastic, also for liquids 1,5 0 4
More informationTECHNICAL DATA. Pressure Regulation 531a. April 24, 2009
April 24, 29 Pressure Regulation 531a 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking
More informationAssembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable
Page 1 von 8 Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV 100-575, top reparable Content Seite 0 Legend 2 1 Overview 2 2 Accumulator assembly and installation
More information1805 Series Relief Valves
Instruction Manual Form 1211 1805 Series October 2011 1805 Series Relief Valves! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion
More informationFor use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY
For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum : FOR OUTDOOR USE ONLY Small Tank LP Kit (STLPK) Installation & Operation Instructions Installation We suggest
More informationHigh Pressure Cylinder Valves
High Cylinder Valves CBA series Commercial and POL Style Acetylene Cylinder Valves O-Ring seal type 8 CBO series Vertical Outlet Acetylene Valve with Handwheel for Collar Style Cylinders 9 CBH/CBI series
More informationHotspotter. Model WB-100 Professional Series. Assembly, Testing & Operating Instructions. Safety Information:
Hotspotter Model WB-100 Professional Series Assembly, Testing & Safety Information: Safety publications related to safe practice and use: CSA 2-94 U.S. Requirements for Hand-Held LP Torches for use with
More informationLITTLE MAX MODEL 50G 50,000 BTU PROPANE TORCH
LITTLE MAX MODEL 50G 50,000 BTU PROPANE TORCH INSTRUCTION MANUAL MODEL 50G PROPANE TORCH ASSEMBLY, TESTING, AND OPERATING INSTRUCTIONS PLEASE READ AND RETAIN THIS INFORMATION FOR FUTURE REFERENCE DO NOT
More informationRARS5000 AIR BODY SAW OWNER S OPERATING MANUAL
RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL DESCRIPTION 1. No mar 2. No mar tip 3. Housing grip 4. Trigger 5. Air inlet 6. Air inlet plug 7. Plastic board Important! It is essential that you read the
More information2.0 INSTALLATION & SERVICE
Installation, Operation, and Maintenance Instructions MODEL 5600 / 5600R January 2005 CONTENTS 1.0 GENERAL 1.1 5600 Model Number Information -----------------------------------------------------------------------
More information4-W GAS ODORIZER WITH POSITIVE ACTION INDICATOR GAUGE (300 PSIG) 2014 INFORMATION MANUAL SUBMITTED BY:
4-W GAS ODORIZER WITH POSITIVE ACTION INDICATOR GAUGE (300 PSIG) 2014 INFORMATION MANUAL SUBMITTED BY: #3, 1470 28 Street NE Calgary, Alberta Canada, T2A 7W6 Phone: (403) 569-8566 Fax: (403) 207-5110 Submitted
More informationshutoff valves 900 Series psig Manual Shutoff Valves
0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on
More informationTECHNICAL DATA CAUTION
Page 1 of 12 1. DESCRIPTION The Viking Model C-2 Pilot Pressure Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking
More informationBS Series Basket Strainer
BS Series Basket Strainer Operating, Installation, & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems. Dated 04-26-12 PRESSURE DROP SIMTECH strainers are engineered to offer the lowest
More informationGAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS
GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS CONTINENTAL INDUSTRIES, INC. The Ultimate Connection CONTINENTAL INDUSTRIES, INC. ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, Inc.,
More informationMounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators
Supply Pressure Regulator Type 4708 Type 4708-5352 on Type 3730 Positioner Type 4708-52 with filter receptacle Type 4708-6252 on Type 3372 ctuator Fig. Supply pressure regulators Mounting and Operating
More informationCable Glands. Special Applications. RoHS Compliance. Plastic & Metal Cable Glands Adapters Reducers & Enlargers Grommets & Accessories
able Glands RoHS ompliance Plastic & Metal able Glands dapters Reducers & Enlargers Grommets & ccessories L File #: E363825 cable gland is a device that allows the user to pass a cable, wire or tube into
More informationSection 3- Repair and Calibration Procedures
Section 3- Repair and Calibration Procedures 1. Refrigerant Removal Procedures 2. Scale/PC Board Recalibration Procedure 3. PC Board Configuration Procedure of AR400 4. Scale Tare Procedure 5. Gauge Calibration
More informationAPPS-160 Gen 2 User Manual
APPS-160 Gen 2 User Manual Applicable Products: PN 11914406 - APPS-160 10 to 50 PSIG operating pressure PN 11918618 - APPS-160 40 to 85 PSIG operating pressure Rev 9/16/2004 Chart Ind. www-chart-ind.com
More informationIndustrial Products. Innovative Solutions for Gas Management Systems. Global Gas Management Technology. Enterprises Innovator Medica Westwinds
Industrial Products Innovative Solutions for Gas Management Systems Global Gas Management Technology Enterprises Innovator Medica Westwinds www.westernenterprises.com GENERAL INFORMATION GENERAL INFORMATION/ORDERING
More informationAIR CHUCKS, TIRE GAUGES AND INFLATOR GAUGES
Series AIR CHUCKS, TIRE GAUGES AND INFLATOR GAUGES Standard Air Chucks 374 Flow-Thru Air Chucks 375 Standard Pencil Tire Gauges 376 Dual Foot Tire Gauges 377 Dial Tire Gauges 378 Digital Tire Gauges 379
More informationSIMPLAIR PIPING TOOL. JXT Company
SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.
More informationINSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)
P/N 126905-01 Rev. B 11/2016 INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235) For All Single, Dual and Triple Burner Natural and Propane/LP Gas Logs P126905-01 For
More informationInstruction Manual Updated 7/26/2011 Ver. 2.2
4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:
More informationPLUMBING WATER & GAS TRADE CATALOGUE
PLUMBING WATER & GAS TRADE CATALOGUE 2015 Index Plumbing, Water & Gas Hoses & Fillers P-04 Tanks Containers Accessories P-07 PumpsP-11 Water is our most precious resource and a necessity when camping and
More informationTECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1
Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a
More information299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012
Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of
More informationSpeed control assembly model A-1
Pressure Regulation 533a 1. DESCRIPTION The Viking Speed Control Assembly provides adjustment of the opening speed of Viking Deluge Valves, and adjustment of both the opening and closing speed of Viking
More informationaccidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS
18 GAUGE 1-1/4 INCH BRAD NAILER Model: 7611 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
More informationModel: AT-1000 L.P.G. FREEZE VALVE
Model: AT-1000 P/N: 2156006200 3829 Forest Parkway Suite 500 Wheatfield, NY 14120-3763 Phone: 716-629-3802 Fax: 716-693-9162 solutions@viatran.com www.viatran.com 1 OPERATION AND MAINTENANCE INSTRUCTIONS
More informationG7S Hand Pump Owner s Manual
G7S Hand Pump Owner s Manual Copyright Air Venturi 2018 Version 4-18 Specifications 24.80 inches long closed 43.31 inches long extended 4500 psi/310 bar max pressure Features Integral manometer (pressure
More informationCASH VALVE CRYOGENIC CONTROLS
SH VLVE ryogenic control for pressure build regulators, pressure reducing valves, final line gas valves and combination pressure build economizer valves. Description ryogenics the science of materials
More informationOperation Manual Piston Sensed Gas Pressure Regulators
687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Operation Manual Piston Sensed Gas Pressure Regulators (Models KT9, KT10, Welded KT10, KT12) Table of Contents:
More informationOwner's Manual and Instructions
Owner's Manual and Instructions Hand Held Torches MODEL OUTPUT (Btuh) FUEL 161-D (Cast Head) 172-D (Steel Head) 500,000 Propane Vapor Withdrawal Congratulations! You have purchased the finest torch available.
More informationSCHRADER TANK VALVES FOR USE IN AIR BLADDER APPLICATIONS, BICYCLE SUSPENSION SYSTEMS, TELECOMMUNICATIONS, WATER STORAGE SYSTEMS, ETC.
SCHRADER TANK VALVES FOR USE IN AIR BLADDER APPLICATIONS, BICYCLE SUSPENSION SYSTEMS, TELECOMMUNICATIONS, WATER STORAGE SYSTEMS, ETC. Demand an authentic Schrader valve built by the company that set the
More informationTypes 749B and R130 Changeover Manifolds
Instruction Manual MCK-1179 Types 749B and R130 June 2012 Types 749B and R130 Changeover Manifolds TYPE HSRL-749B TYPE 64SR/122 TYPE R130/21 TYPE 749B/21 Figure 1. Changeover Manifolds and Regulator Assemblies
More informationHalsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!
Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4410FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE LOCATED
More informationMIDDLESEX COUNTY COLLEGE EDISON, NJ LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS
MIDDLESEX COUNTY COLLEGE EDISON, NJ 08818 LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS The College is soliciting bids to award a Local Supplier Blanket Order agreement for the purchase of supplies for the
More informationB-Too Drilling and Tapping Machine
Material Specifications Powered by hand or with Ridgid 690 (TM-29) High strength, modular aluminum and steel components Inserts any 3 /4" to 1" corporation stop under pressure Extracts threaded corporation
More informationDBML-60/80 Squeeze Tool
DBML-60/80 Squeeze Tool OPERATORS MANUAL Description The Mustang Model DBML-60/80 Hydraulic squeeze tool has been manufactured since 1995. A Mustang 3 3/4 bore doubleacting cylinder producing 41,000 lbs
More informationDescription Pressure range Connection thread Device Page
Pressure Regulator Pressure range onnection thread Device Page max. 22 l/min miniature -850 0 mbar 1 8 NPT V800.02 max. 22 l/min miniature -850 0 mbar 10-32 and flange V900.02 max. 0 l/min precise -1 +0,.4
More informationPressure Regulators. Instructions for Use
Pressure Regulators Instructions for Use 702-0032.11 May 2014 1. Symbols Warning! Caution! Indicates a potentially hazardous situation which, if not avoided, could result in personal injury to the user
More informationCAPITAL CONTROLS SERIES NXT3000
CAPITAL CONTROLS SERIES NXT3000 Modular design gas feed system with self contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuumoperated, solution-feed gas dispensing
More informationRight-Angle Tube Roller Model
SPECIFICATIONS Model no. Free Speed (RPM) Throttle Rotation Max. Torque Ft-Lb Air Pressure psi Air Inlet Hose Air Flow @Free Speed Spindle Weight 909-1700 95 Lever type Reversible 240 90 1/2 NPT 1/2 I.D.
More informationV43 Pressure Actuated Water Regulating Valve
FANs 125, 121 Product/Technical Bulletin V43 Issue Date 0996 V43 Pressure Actuated Water Regulating Valve The V43 Pressure Actuated Water Regulating Valves are designed to regulate water flow for water-cooled
More informationPlease Contact Do It American for Pricing
J Product List Please Contact Do It American for Pricing BK-22-01 27.2 Cu. Ft. Portable Bypass System Box and Regulation only (7 IWC) BK-22-02 27.2 Cu. Ft. Portable Bypass System Box, Regulation, and Cylinder
More informationSUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide
SUMMITTM 400 & 600 Natural Gas Barbecues Step-By-Step Guide W E B E R W E B E R W E B E R W E B E R Summit 400 NG Summit 600 NG CANADIAN GAS ASSOCIATION R A P P R O V E D WARNING: Follow all leak check
More informationContinental Industries STEEL SERVICE TEES or FAX Visit
Continental Industries STEEL SERVICE TEES 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and
More informationOperating Instructions Models and Hydrostatic Test Pumps
Operating Instructions Models 33100 and 33101 Hydrostatic Test Pumps 33100 DIMENSIONS: WEIGHT: PUMP: MOTOR: CONTROL: GAUGE: DISCHARGE HOSE: 16 (40cm) L x 22 (55cm) W x 18 (45cm) H 87 lbs., 39.5 kg Triplex
More information7625 West New York Street Indianapolis IN Phone: Fax: Order Desk:
Flotec was incorporated on June 30, 1983 as a wholly owned subsidiary of Davidson, Inc. Since the beginning, the core activity has been manufacturing for the medical, industrial, and OEM markets. The products
More informationAIR/OVER HYDRAULIC JACK 20 TON
AIR/OVER HYDRAULIC JACK 0 TON 4487 ASSEMBLY AND OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com Copyright 999 by Harbor Freight Tools.
More informationHigh Pressure Equipment Taper Seal Valves, Fittings and Tubing
igh quipment Taper Seal Valves, ittings and Tubing 0,000 and,000 psi service igh quipment Company has developed the Taper Seal line of products to assure safe and easy plumbing through,000 psi. These needle
More informationIndustrial Products Catalog Tank Valves
Industrial Products Catalog Tank Valves Schrader International core competencies include high volume precision machining, assembly and testing of fluid control devices. Since developing the first pneumatic
More informationPremium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.
Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces
More informationINSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator
INSTRUCTION MANUAL CVS P37 LP Gas Reducing Regulator The CVS Controls P37 Regulator is a non-relieving, pressure reducing regulator suitable for use in LP gas applications (Natural Gas and Propane). As
More informationOperating Instructions Model and Hydrostatic Test Pump
Operating Instructions Model 39300 and 39301 Hydrostatic Test Pump Dimension Weight Pump Style Capacity Pressure Motor Lubrication Control Gauge Inlet Connection Outlet Connection Discharge Hose Hose Ends
More informationHigh Pressure Gas Master Valves
High Pressure Gas Master Valves 9560 Series The 9560 Series high pressure brass valves are used on cylinder filling panels, tube trailers, and other high pressure manifolds and piping systems. The 9560
More informationUser Instruction Manual
User Instruction Manual 4500 psi Air Compressor Ver 2, 1.18 Contents Parts Included...3 Assembly Instructions...3-5 Operation Instructions...6-7 Oil Change Intervals...8 Air Filter Replacement...9 Setting
More informationINSTALLATION AND OPERATION INSTRUCTIONS
INSTALLATION AND OPERATION INSTRUCTIONS Liquid propane units are designed and certified for use, only with household liquid propane supply. Do not use " portable " propane tanks of less than 20-lbs. capacity.
More information2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL
2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL Model: 52024 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement,
More informationPressure Dump Valve Service Kit for Series 3000 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator
More information