1 Centriflow Plus 3 High-pressure plug fan - Technical Data
2
3 Contents General description...3 General survey chart...4 Design description Fan Impeller...5 Fan Inlet...5 base with base frame...5 Hub...5 Air flow sensor...6 Tolerances and quality...6 Directive for machinery...6 s...6 Ordering code...7 Acoustic details-explanation...8 Technical Data Dimensions and weights, data, Fan charts, Sound data GPEB GPEB GPEB GPEB GPEB GPEB GPEB GPEB Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
4 General description The direct driven CENTRIFLOW Plus 3 plug fans are available in 8 sizes and cover airflows up to 1 m3/s and pressure rises up to 3 Pa. The impeller has backward curved blades. The CENTRIFLOW Plus 3 is available in normal version. The fans are supplied with an integrated air flow sensor with two measuring points as standard. Fans are supplied in a right-hand version (viewed from the fan inlet). Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
5 General survey chart Air flow, m 3 /h Total pressure rise, Pa In lower pressure we recommend to use our Centriflow Plus plug fans Air flow, m 3 /s Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
6 Design description Fan Impeller The impeller is made of sheet steel, welded and it comes with a reinforcement ring. The impeller painted with 6 μm thick epoxy powder paint, (colour: RAL 629, green). The impellers are dynamically balanced to ISO Standard G 2.5 (sizes 35 71) and G 6.3 (size 31) at the maximum speed. The vibration level of the fan is below 7.1mm/s RMS. Fan Inlet The design of the fan inlet is vitally important to the fan efficiency and the low level of sound generated by the fan. The inlet cones are deep-drawn in one piece and are fitted to the front plate. The inlet cone and end panel are made of galvanized sheet steel. base with base frame The motor base and the fan base frame are made of welded sheet steel. base is painted with 1 μm thick epoxy powder paint (colour: RAL 75, dark grey). Base frames are hot-dip galvanised as standard but to special order they are available also as painted. Hub The fan impeller is equipped with a hub which is made of welded steel. The hub is painted with 1 μm thick epoxy powder paint. Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
7 Design description Air flow sensor The air flow sensor is used for measuring the airflow of the plug fans. The method is based on differential pressure. The pressure is measured at a specific point in the inlet cone and the reference pressure is measured upstream of the inlet cone. The air flow sensor is supplied factory mounted in the inlet cone. The airflow is calculated as a function of the coefficient k and the differential manometer reading Δpm from the expression: Qv = 1 k Δp m Qv = airflow (m 3 /s) k = coefficient of the fan (k-factor) Δpm = measured pressure difference (Pa) Directive for Machinery Centriflow Plus 3 is not a product which is ready for use but it is designed for mounting in an air handling unit. The manufacturer of the air handling unit must follow all instructions according to Directive for Machinery, EMC Directive and Low Voltage Directive as well as use all necessary protective measures. s The CENTRIFLOW Plus fans are normally supplied with the motor mounted. The motors are footmounted high-efficiency IE2 motors according to IEC standards, Degree of protection IP 55. In case of Marine applications motors with Classification Society approval according to the customer s specification are supplied. options like thermistors other IP classes or spaces are available on request. Fan size k-factor GPEB ,2 GPEB ,1 GPEB ,1 GPEB ,2 GPEB ,9 GPEB ,8 GPEB ,2 GPEB ,3 Tolerances and quality The particulars of the fans are given with the tolerance specified in DIN , Class 1. Fan performance has been measured in accordance with ISO 581 and The production process is certificated to ISO91 and the environmental system to ISO 141. Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
8 Accessories GPEZ-9-1-ccc-1- GPEZ-42-1-ccc-d- GPEZ-42-1-ccc-d- Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
9 Accessories 1 Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
10 Ordering code Plug fan GPEB-1-1-ccc-dd- Accessories Fan size (ccc) 31, 35, 4, 45, 5, 56, 63, 71 size IEC (dd) 11 = = = = 18 2 = 2 APAL = IEC standard motor Number of poles (a) Output in kw, e.g. 3 = 3 kw (bbbbb) APAL-a-bbbbb-c-2-e Air flow measurement with four nipples Inlet protective screen Flexible connection Anti-vibration mountings, Rubber Anti-vibration mountings, Steel spring GPEZ-9-1-ccc-1- GPEZ-13--ccc-d- GPEZ-21--ccc-d- GPEZ-42-1-ccc-d- GPEZ-43-1-ccc-d- Painted finish, GPEZ-6--ccc-d- d = 2 Powder painted, 1 μm d = 3, Wet painted, 25 μm in 3 coats, impeller with 1 μm Voltage/tension (c) 2 = 3 x 4/69V 5Hz With thermistors (2) Supplier (e) 7 = Fläkt Woods IE2 motor 1 = ABB IE2 motor APAM = IEC standard motor,. marine version APAM-a-bbbbb-c-d-1 Number of poles (a) Output in kw, e.g. 3 = 3 kw (bbbbb) Voltage/tension (c) 2 = 3x38V 5Hz 7 = 3x44V 6Hz Classification Society (d) 2 = Bureau veritas (BV) 3 = Lloyds (LRS) 4 = Det norske Veritas (DNV) 5 = Germanischer Lloyd (GL) 6 = American Bureau of Shipping (ABS) 1 = Generation Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
11 Acoustic Details - explanation Acoustic Details The total A-weighted sound power level LWA generated at the outlet of an open discharge fan is specified in the fan chart. Correction factors are tabulated in the table below. The following expression can be used for breaking down the sound into each octave band and sound path: L Wokt(s) = L WA + K okt(s) where Kokt(s) can be obtained from the table. The following expression can be used for calculating the A-weighted sound power level at the fan inlet: L WA(2) = L WA + ΔL..... where the correction factor ΔL can be obtained from the table. Acoustic Details - Table Correction Kokt, db GPEB Sound path Speed range Octave band, centre frequency, Hz (s) r/min ΔL To outlet s= To inlet s= , ,3 Symbols used L WA A-weighted total sound power db(a) s Sound path - L WA(2) A-weighted total sound power level to inlet db(a) L Wokt(s) Sound power level at each octave band and sound path (without A-weighting) db K okt(s) Correction factor for breaking down the sound level into each octave band and sound path db Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
12 Technical Data - GPEB A C B 11 GPEZ-42 GPEZ-43 IEC A B C φ H Front Back SD3 SD SD3 SD3 GPEZ-42 GPEZ-43 H Ø Ø7 Without load 94 data Output kw IEC Fläkt Woods motors IE2, 4V 5Hz nominal rpm speed/ frequency r/min Hz Antivibration mountings Rubber Compression GPEZ d- Spring Compression GPEZ d- Fan GPEB MB APAL ,1 d =1 d = GPEB ,5 132SB APAL , d =1 d = ABB motors IE2, 4V 5Hz GPEB APAL ,7 d =1 d = GPEB ,5 132 APAL ,9 d =1 d = Marine motors, 38V 5Hz GPEB APAM d ,4 d =1 d = GPEB ,5 132 APAM d ,4 d =1 d = Marine motors, 44V 6Hz GPEB ,6 112 APAM d ,4 d =1 d = GPEB ,4 132 APAM d , d =1 d = Total Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
13 Technical Data - GPEB Fan charts r/min ps (Pa) db(a) ,3,5,7,9 1,1 1,3 1,5 1,7 1,9 2,1 2,3 q v (m 3 /s),3,5,7,9 1,1 1,3 1,5 1,7 1,9 2,1 2, P (kw) 3 41 r/min Sound data Correction Kokt, db GPEB Sound path Speed range Octave band, centre frequency, Hz (s) r/min ΔL To outlet s= To inlet s= , ,4 Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
14 Technical Data - GPEB A C B 11 GPEZ-42 GPEZ-43 IEC A B C φ H Front Back SD3 SD SD3 SD3 GPEZ-42 GPEZ-43 H Ø Ø7 Without load 94 data Output kw IEC Fläkt Woods motors IE2, 4V 5Hz nominal rpm speed/ frequency r/min Hz Antivibration mountings Rubber Compression GPEZ d- Spring Compression GPEZ d- Fan GPEB MB APAL ,9 d =1 d = GPEB ,5 132SB APAL ,8 d =2 d = GPEB ,5 132SC APAL ,6 d =2 d = ABB motors IE2, 4V 5Hz GPEB APAL ,4 d =1 d = GPEB ,5 132 APAL ,4 d =2 d = GPEB ,5 132 APAL ,5 d =2 d = Marine motors, 38V 5Hz GPEB APAM d ,9 d =1 d = GPEB ,5 132 APAM d ,8 d =2 d = GPEB ,5 132 APAM d ,1 d =2 d = Marine motors, 44V 6Hz GPEB ,6 112 APAM d ,5 d =1 d = GPEB ,4 132 APAM d ,9 d =2 d = GPEB ,6 132 APAM d ,4 d =2 d = Total Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
15 Technical Data - GPEB Fan charts r/min ps (Pa) db(a) ,5 1 1,5 2 2,5 3 q v (m 3 /s),5 1 1,5 2 2, r/min P (kw) Sound data Correction Kokt, db GPEB Sound path Speed range Octave band, centre frequency, Hz (s) r/min ΔL To outlet s= To inlet s= , ,7 Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
16 Technical Data - GPEB A C B 11 GPEZ-42 GPEZ-43 IEC A B C φ H Front Back SD4 SD SD4 SD4 GPEZ-42 GPEZ-43 H Ø Ø7 Without load 94 data Output kw IEC Fläkt Woods motors IE2, 4V 5Hz nominal rpm speed/ frequency r/min Hz Antivibration mountings Rubber Compression GPEZ d- Spring Compression GPEZ d- Fan GPEB ,5 132SB APAL ,1 d =1 d = GPEB ,5 132SC APAL ,9 d =1 d = GPEB MLA APAL ,5 d =1 d = ABB motors IE2, 4V 5Hz GPEB ,5 132 APAL , d =1 d = GPEB ,5 132 APAL ,8 d =1 d = GPEB APAL ,3 d =1 d = Marine motors, 38V 5Hz GPEB ,5 132 APAM d ,4 d =1 d = GPEB ,5 132 APAM d ,3 d =1 d = GPEB APAM d ,5 d =1 d = Marines motors, 44V 6Hz GPEB ,4 132 APAM d ,8 d =1 d = GPEB ,6 132 APAM d ,5 d =1 d = GPEB APAM d ,7 d =1 d = Total Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
17 Technical Data - GPEB Fan charts r/min ps (Pa) db(a) q v (m 3 /s) P (kw) r/min Sound data Correction Kokt, db GPEB Sound path Speed range Octave band, centre frequency, Hz (s) r/min ΔL To outlet s= To inlet s= , ,3 Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
18 63 6 A C B 11 GPEZ-42 GPEZ-43 GPEZ-42 Ø IEC A B C φ H Front Back H SD4 SD SD4 SD4 GPEZ-43 Ø7 Without load 94 data Output kw IEC Fläkt Woods motors IE2, 4V 5Hz nominal rpm speed/ frequency r/min Hz Antivibration mountings Technical Data - GPEB GPEZ d- GPEZ d- Fan GPEB ,5 132M APAL ,8 d = 1 d = GPEB ,5 132MA APAL , d = 1 d = GPEB ,5 132SC APAL ,5 d = 1 d = GPEB MLA APAL ,5 d = 1 d = ABB motors IE2, 4V 5Hz GPEB ,5 132 APAL ,8 d = 1 d = GPEB ,5 132 APAL , d = 1 d = GPEB ,5 132 APAL ,4 d = 1 d = GPEB APAL ,3 d = 1 d = Marine motors, 38V 5Hz GPEB ,5 132 APAM d ,8 d = 1 d = GPEB ,5 132 APAM d , d = 1 d = GPEB ,5 132 APAM d ,2 d = 1 d = GPEB APAM d ,5 d = 1 d = Marine motors, 44V 6Hz GPEB ,4 132 APAM d ,8 d = 1 d = GPEB ,6 132 APAM d ,3 d = 1 d = GPEB ,6 132 APAM d , d = 1 d = GPEB APAM d ,7 d = 1 d = Total Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
19 Technical Data - GPEB Fan charts r/min ps (Pa) db(a) q v (m 3 /s) r/min P (kw) Sound data Correction Kokt, db GPEB Sound path Speed range Octave band, centre frequency, Hz (s) r/min ΔL To outlet s= To inlet s= , ,7 Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice7
20 Technical Data - GPEB A C B 11 GPEZ-42 GPEZ-43 GPEZ-42 Ø IEC A B C φ H Front Back SD5 SD5 H GPEZ-43 Ø7 Without load 94 data Antivibration mountings speed/ frequency Output kw IEC nominal rpm r/min Hz GPEZ d- GPEZ d- Fan Total Fläkt Woods motors IE2, 4V 5Hz GPEB MLA APAL ,5 d = 1 d = GPEB MLA APAL , d = 1 d = GPEB MLB APAL , d = 1 d = GPEB MLB APAL ,3 d = 1 d = ABB motors IE2, 4V 5Hz GPEB APAL ,8 d = 1 d = GPEB APAL ,7 d = 1 d = GPEB APAL , d = 1 d = GPEB APAL ,3 d = 1 d = Marine motors, 38V 5Hz GPEB APAM d ,1 d = 1 d = GPEB APAM d , d = 1 d = GPEB APAM d ,4 d = 1 d = GPEB APAM d ,6 d = 1 d = Marine motors, 44V 6Hz GPEB APAM d ,7 d = 1 d = GPEB ,5 16 APAM d ,6 d = 1 d = Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
21 Technical Data - GPEB Fan charts r/min ps (Pa) db(a) q v (m 3 /s) r/min P (kw) Sound data Correction Kokt, db GPEB Sound path Speed range Octave band, centre frequency, Hz (s) r/min ΔL To outlet s= To inlet s= , Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
22 Technical Data - GPEB A C B 11 GPEZ-42 GPEZ-43 IEC A B C φ H Front Back GPEZ-42 Ø SD5 SD6 H SD5 SD6 GPEZ-43 Ø7 Without load 94 data Antivibration mountings speed/ frequency Output kw IEC nominal rpm r/min Hz GPEZ d- GPEZ d- Fan Total Fläkt Woods motors IE2, 4V 5Hz GPEB MLA APAL ,5 d = 1 d = GPEB MLB APAL ,6 d = 1 d = GPEB ,5 18MLA APAL ,6 d = 1 d = ABB motors IE2, 4V 5Hz GPEB APAL ,7 d = 1 d = GPEB APAL ,6 d = 1 d = GPEB ,5 18 APAL ,6 d = 1 d = Marines motors, 38V 5Hz GPEB APAM d , d = 1 d = GPEB APAM d ,9 d = 1 d = GPEB ,5 18 APAM d ,9 d = 1 d = Marine motors, 44V 6Hz GPEB APAM d ,3 d = 1 d = GPEB ,5 16 APAM d ,3 d = 1 d = Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
23 Technical Data - GPEB Fan charts r/min ps (Pa) db(a) q v (m 3 /s) r/min P (kw) Sound data Correction Kokt, db GPEB Sound path Speed range Octave band, centre frequency, Hz (s) r/min ΔL To outlet s= To inlet s= , ,6 Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
24 Technical Data - GPEB A C 11 B GPEZ-42 GPEZ-43 IEC A B C φ H Front Back GPEZ-42 Ø SD5 SD6 H SD5 SD6 GPEZ-43 Ø7 Without load 94 data Antivibration mountings speed/ frequency Output kw IEC nominal rpm r/min Hz GPEZ d- GPEZ d- Fan Total Fläkt Woods motors IE2, 4V 5Hz GPEB MLA APAL ,9 d = 1 d = GPEB MLB APAL ,6 d = 1 d = GPEB ,5 18MLA APAL ,1 d = 1 d = GPEB MLB APAL ,8 d = 1 d = ABB motors IE2, 4V 5Hz GPEB APAL ,1 d = 1 d = GPEB APAL ,6 d = 1 d = GPEB ,5 18 APAL ,1 d = 1 d = GPEB APAL ,9 d = 1 d = Marine motors, 38V 5Hz GPEB APAM d ,4 d = 1 d = GPEB APAM d ,8 d = 1 d = GPEB ,5 18 APAM d ,3 d = 1 d = GPEB APAM d ,2 d = 1 d = Marine motors, 44V 6Hz GPEB APAM d ,6 d = 1 d = GPEB ,5 16 APAM d ,7 d = 1 d = GPEB APAM d ,6 d = 1 d = Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
25 Technical Data - GPEB Fan charts r/min ps (Pa) db(a) q v (m 3 /s) P (kw) r/min Sound data Correction Kokt, db GPEB Sound path Speed range Octave band, centre frequency, Hz (s) r/min ΔL To outlet s= To outlet s= To inlet s= , ,6 Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
26 95 92 A GPEZ-42 Ø C 11 B H GPEZ-42 GPEZ-43 IEC A B C φ H Front Back SD6 SD SD6 SD SD6 SD7 GPEZ-43 Without load 94 Ø7 data Output kw IEC Fläkt Woods motors IE2, 4V 5Hz nominal rpm speed/ frequency r/min Hz Antivibration mountings Technical Data - GPEB GPEZ d- GPEZ d- Fan GPEB MLA APAL ,7 d = 1 d = GPEB MLB APAL ,2 d = 1 d = GPEB ,5 18MLA APAL ,9 d = 2 d = GPEB MLB APAL ,5 d = 2 d = GPEB MLA APAL ,6 d = 3 d = ABB motors IE2, 4V 5Hz GPEB APAL ,8 d = 1 d = GPEB APAL ,2 d = 1 d = GPEB ,5 18 APAL , d = 2 d = GPEB APAL ,6 d = 2 d = GPEB APAL ,6 d = 3 d = Marine motors, 38V 5Hz GPEB APAM d , d = 1 d = GPEB APAM d ,4 d = 1 d = GPEB ,5 18 APAM d ,1 d = 2 d = GPEB APAM d ,8 d = 2 d = GPEB APAM d ,8 d = 3 d = Marine motors, 44V 6Hz GPEB APAM d ,3 d = 1 d = GPEB ,5 16 APAM d ,4 d = 1 d = GPEB APAM d ,3 d = 2 d = GPEB APAM d ,3 d = 2 d = GPEB APAM d ,8 d = 3 d = Total Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
27 Technical Data - GPEB Fan charts r/min p s (Pa) db(a) q v (m 3 /s) P (kw) r/min Sound data Correction Kokt, db GPEB Sound path Speed range Octave band, centre frequency, Hz (s) r/min ΔL To outlet s= To outlet s= ,8 To inlet s= , ,8 Fläkt Woods Oy 516 GB Specifications are subject to alteration without notice
28 We Bring Air to Life Fläkt Woods is a global leader in air management. We specialise in the design and manufacture of a wide range of air climate and air movement solutions. And our collective experience is unrivalled. Our constant aim is to provide systems that precisely deliver required function and performance, as well as maximise energy efficiency. Solutions for all your air climate and air movement needs Fläkt Woods Ventilation Solutions supplies a wide range of centrifugal fans for ventilation applications: Centriflow Plus Plug fans with record-breaking efficiency level. Available with wide motor range including integral inverter motors. Roofmaster Roof fans characterised by low sound level. Centrimaster Centrifugal fans single or double inlet, för direct and belt drive. Centrimaster fans with backward curved impellers are characterised by high efficiency and low sound level. Centrilflow Plus 3 GB Copyright 212 Fläkt Woods Group Condesign Infocom AB Fläkt Woods Oy Kalevantie 39, FI-252 Turku, Finland Tel Fax See global website for international sales offices
CJTX-C 15/15 0,75 (2V) F-400. Impeller size 2-speed fan. Installed power. (r/min) 230 V 400 V 690 V (kw) m3/h db(a) (kg)
CJTX-C 400 C/2h belt-driven double inlet extractor fan units. Order code 400 C/2h extractor fan units, with motor and transmission mounted inside the box, to operate outside the fire zone. Fan: Galvanised
More informationSMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA
Official homologation by the European laboratory CSTB according to NF EN12101-3: 2002 CTH Centrifugal roof 400ºC/2h CTH (horizontal) Roof cowl made of polyethylene UV resistant. Structure, roof base support
More informationCHILLED BEAM FLEXICOOL IQID
CHILLED BEAM FLEXICOOL IQID TECHNICAL CATALOGUE 2 Flexicool IQID Chilled beam - Technical catalogue CHILLED BEAM FLEXICOOL IQID The chilled beam Flexicool IQID is an integrated system for ventilation,
More information1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure
Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3
More informationKSB Delta Compact Type Series Booklet
Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,
More informationPressure transmitters EMP 2
Data sheet Pressure transmitters EMP 2 The high accuracy pressure transmitter EMP 2 is designed for monitoring and control in marine and industial applications and offers a reliable pressure measurement,
More informationAutomatic extractor outlet
L-07-2-01e Automatic extractor outlet Type HFA Contents Application Realisation Operation Safety instructions Contents Application Realisation Operation Safety instructions 2 Connection diagram Dimensions
More informationKSB Delta Compact Type Series Booklet
Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,
More informationDMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.
Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:
More informationControl the air. Control your business.
Serpent ventilation A complete ventilation system for successful tunneling and mining operations, including system design, fan station, ducting and installation 1 Control the air. Control your business.
More informationSeries BLK Oil - air cooler
Series BLK Oil - air cooler maintenance friendly design broad performance range compact dimensions rugged cooling matrix low noise emissions comprehensive accessories DE 35 0001 04/2004 Bühler Meß- und
More informationASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom
NE ASM Asynchronous Spindle Motors SEM Limited Faraday Way Orpington, Kent BR 3QT United Kingdom Tel: +44 ()189 8847 Fax: +44 ()189 884884 Email: sales@sem.co.uk Web: www.sem.co.uk Version 4 August 2 Asynchronous
More informationSIHI LPH-X - Liquid Ring Compressors
- Liquid Ring Compressors LPH 50523 LPH 60527 Pressure range: Suction volume range: 0.2 to 1.5 bar 260 to 780 m³/h CONSTRUCTION Sterling SIHI liquid ring compressors are displacement compressors with a
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationAdjustable swirl diffuser ODZA TECHNICAL DATA
Adjustable swirl diffuser ODZA TECHNICAL DATA 2 Adjustable swirl diffuser ODZA Adjustable ceiling swirl diffuser ODZA is intended for commercial and industrial buildings with a large room volume and high
More informationSupply air diffuser ROFB, RPFB
Supply air diffuser ROFB, RPFB ROFB and RPFB are supply air diffusers with an integrated plenum box for freely suspended installation in a ceiling. The diffuser ROFB comes with an unperforated and RPFB
More informationChilled beam iq Star WEGA II
Chilled beam iq Star WEGA II Key features Ventilation Water Heating and cooling Adjustable induction Flow Pattern Control In option: Demand Controlled Ventilation, Pressure independent, Electrical heating,
More informationPrewired position switches FA series
2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45
More informationPORTABLE GAS FREEING FAN
PORTABLE GAS FREEING FAN TYPE MPV APPLICATIONS Typical application for this fan is mechanical ventilation of hazardous zones and cargo tanks onboard ships. To be mounted into tank openings on deck. DESIGN
More informationBULLETIN FA-300. February 1999 AXIAD II. Adjustable Pitch Airfoil Axial Flow Fan
BULLETIN FA-300 February 1999 AXIAD II Adjustable Pitch Airfoil Axial Flow Fan AXIAD II The axial flow fan with: High efficiency Low sound level Adjustable pitch blades Complete range of accessories Axial
More informationLindabSolus. Supply air beam. lindab we simplify construction
lindab we simplify construction Lindab 03.2016 Lindab Ventilation. All forms of reproduction without written permission are forbidden. is the registered trademark of Lindab AB. Lindab's products, systems,
More informationSafety relief valves Type BSV-8
Data sheet Safety relief valves Type BSV-8 BSV is a standard, back pressure independent safety relief valve, especially designed for protection of small components against excessive pressure and as a pilot
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationPressure switch and Thermostat CAS
Data sheet Pressure switch and Thermostat CAS The CAS Series consists of a series of pressure controlled switches and temperature controlled switches. In this series, special attention has been given to
More informationPRODUCT CONFIGURATOR AT mcr Monsun. smoke extraction and air supply axial-flow fans
PRODUCT CONFIGURATOR AT WWW.MERCOR.COM.P mcr Monsun smoke extraction and air supply axial-flow fans APPICATION mcr Monsun fans are designed to extract hot air, smoke and exhaust gases from fire-exposed
More informationPage - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302
CONTENTS. Page - SPECIFICATIONS 200 SPECIFICATION 200 SELECTION CHART PFC 201 SELECTION CHART 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 2 204 PERFORMANCE CURVE 3 205 PERFORMANCE CURVE
More informationAXIAL FLOW FANS GENERAL INFORMATION
ELTA IMPELLER RANGE AXIAL INTRODUTION TEST STANDARDS The Elta impeller ranges included in this catalogue have harnessed the latest technology in axial impeller design, resulting in enhanced pressure development,
More informationPressure Reducing Valve DMV 755 set range: 1,0-9,0 bar
Pressure Reducing Valve DMV 755 set range:,0-9,0 bar Advantage pressure setting possible at any time, also during operation high reproducibility of the set pressure high level of operating safety and long
More informationPressure switch and Thermostat KPS
Data sheet Pressure switch and Thermostat KPS The KPS Series consists of a series of pressure and temperature controlled switches. In this series, special attention has been given to meeting demands for
More informationLiquid ring vacuum pumps in compact design
Liquid ring vacuum pumps in compact design LEM 25, LEM 5 Pressure range: Suction volume flow: 33 to 113 mbar 4 to 6 m³/h CONSTRUCTION SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationHigh Pressure Breathing Air Compressors
High Pressure Breathing Air Compressors [ Full variety for different applications] MSA offers a comprehensive range of high pressure breathing air compressors for both the firefighting and diving market,
More informationTurbo Blowers. Combustion Excellence Since Features. Benefits
Turbo Blowers Features Integral molded scroll design Turbine bladed impeller Steel inlet guard Precisely balanced impellers eliminate vibration Complete line of available accessories for adapting to any
More informationPressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview
f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationVRF. Technical Data Book. DVM S ECO for Europe (R410A, 50Hz, HP) Model : AM***KXMDGH/EU
VRF Technical Data Book DVM S ECO for Europe (R410A, Hz, HP) Model : AM***KXMDGH/EU History Version Modification Date Remark 1 Newly Release the TDB 15.12.15 Nomenclature Outdoor Units Model Names AM 080
More informationSPCH/ Blowing block
> > for linear stretch blow moulding machines > > Compact and safe design > > Best suited for PET bottles up to litres, depending on cycle time Technical features Medium: Compressed air (purity class 3..3
More informationPressure switch and Thermostat Type KPS
MAKING MODERN LIVING POSSIBLE Data sheet Pressure switch and Thermostat Type KPS The KPS Series consists of a series of pressure and temperature controlled switches. In this series, special attention has
More informationCADENZA
---------------------------------------------- ---------------------------------------------------------------------- Attenuator with aerodynamically shaped splitters for rectangular ducts GENERAL has
More informationPneumatic pressure switch 20DD
Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better
More informationVARIABLE AIR FLOW REGULATOR
The RCV regulator is a variable air flow self-regulated system (VAV type). It is used to regulate the air flow in an area or room of a building according to a setpoint. The RCV regulator is also available
More informationTECHNICAL DESCRIPTION
TECHNICAL DESCRIPTION Exhaust Hose Reel ser. 865, electric motor driven No. 981118101 Description Limit switches, for hose coiling and uncoiling integrated in drive unit. Motor turns drum via a planetary
More informationTest Summary Report Giraffe 2.0 Hybrid Wind-Solar Power Station - for wind: according to IEC Annex M - for solar: measurement report
Contact person Tanja Tränkle 2016-06-29 4P05805-R01 rev. 1 1 (7) Safety +46 10 516 57 19 Tanja.Trankle@sp.se Innoventum AB Morgan Widung / Marcus Ulmefors Turning Torso office 275 Lilla Varvsgatan 14 211
More informationTechnical information
Technical information 1.1 Design Elektror medium pressure blowers of the RD range are radial ventilators with double-wall impellers made from sheet aluminium respectively from sheet steel. They are directly
More informationLiquid ring vacuum pumps in compact design
Liquid ring vacuum pumps in compact design, Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated and
More information2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure
Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationSafety relief valves, type BSV 8 REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Safety relief valves, type BSV 8 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction....................................................................................... 3
More informationAir Terminal Devices for Every Application
Air Terminal Devices for Every Application Plenum box Ceiling diffusers ATTB 100-315 l/s RHOB RHKP ROFA 14-210 l/s 1) 14-210 l/s 1) 14-185 l/s RPFA 14-185 l/s Swirl diffusers DCKA 4-240 l/s Varimix RSRO
More informationLiquid ring vacuum pumps single-stage
Liquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 Pressure range: Suction volume flow: 150 to 1013 mbar 50 to 270 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum pumps are displacement
More informationOMS Technical Information. Versions OMS. Versions
Versions Versions Mounting flange Shaft Port size European version US version Drain connection Check valve Main type designation Standard flange Cyl. 32 G 1/2 l Yes Yes Cyl. 1.25 in 7/8-14 UNF l Yes Yes
More informationDifferential pressure controls, Type MP 54, 55 and 55A
MAKING MODERN LIVING POSSIBLE Technical brochure Differential pressure controls, Type MP 54, 55 and 55A MP 54 and oil pressure controls are used as safety switches to protect refrigeration compressors
More informationPressure relief valve DHV 716 set range: 0,5-10,0 bar
Pressure relief valve DHV 7 set range: 0,5-0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level of
More informationSafety relief valves Type SFA 15 and SFA 15-50
Data sheet Safety relief valves SFA 15 and SFA 15-50 SFA 15 and SFA 15-50 are standard, back pressure dependent safety relief valves in angleway execution, specially designed for protection of vessels
More informationLiquid ring compressors
Liquid ring compressors KPH 85220, KPH 85227 Compression pressures: Suction volume flow: 2 to 7 bar 940 to 1450 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors
More informationUniflair LE TDAR-TUAR
Uniflair LE TDAR-TUAR Direct Expansion air-cooled units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDAR) >
More informationSTAIRCASE PRESSURIZATION SYSTEM
STAIRCASE PRESSURIZATION SYSTEM Staircase Pressurization System SMOKE AND HEAT CONTROL SYSTEMS: Specification for pressure differential systems NORM: BS EN 12101-6:2005 This norm specifies the pressure
More informationJUMO dtrans p30 Pressure Transmitter
609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure
More informationLiquid ring compressor
Liquid ring compressor KLH 47005, KLH 47105 Compression pressures: Suction volume flow: 2 to 11 bar 56 to 65 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors of
More informationDifferential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting
Data sheet Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Description AVPQ is a self-acting differential pressure and flow controller primarily for use in
More informationOn-Off switch. Selectable manual control for commissioning. Remote start input for control via an irrigation controller, or external sensor.
SPEEDMAN VARIABLE SPEED PUMP SET VARIABLE SPEED PUMP SET PRODUCT DESCRIPTION Variable speed / constant pressure system consisting of a Davey VM vertical multistage pump with Speedman controller, VSD unit,
More informationVLT 2000 Series. How to size your VLT
Selection of frequency converter Usually the size of frequency converter is chosen on the basis of the shaft output, as this may be the only value known. However, if the data are known for both the application,
More informationEvaporator (DX) Freon Applications 1 12 Tons MHF
Evaporator (DX) Freon Applications 1 12 Tons > > Used For small to medium freon applications The Global Leader In Heat Exchange Technology With seven decades of experience and commitment to total client
More informationInstruction Manual. Pipe Friction Training Panel
Instruction Manual HL 102 Pipe Friction Training Panel 100 90 80 70 60 50 40 30 20 10 HL 102 Instruction Manual This manual must be kept by the unit. Before operating the unit: - Read this manual. - All
More informationPressure controls for hydro carbons, zone II applications, Type KPE
MAKING MODERN LIVING POSSIBLE Technical brochure Pressure controls for hydro carbons, zone II applications, Type KPE KPE pressure controls for use in refrigeration and air conditioning systems with hydrocarbons
More informationOPTIBAR P 1010 C Technical Datasheet
Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability
More informationEtanorm V Type Series Booklet
Vertical Low-pressure Pump Etanorm V Type Series Booklet Legal information/copyright Type Series Booklet Etanorm V All rights reserved. The contents provided herein must neither be distributed, copied,
More informationPressure Reducing Valve DMV 750 set range: bar
Pressure Reducing Valve DMV 750 set range:.0-6.0 bar Advantage pressure setting possible at any time, also during operation hermetically sealed by valve diaphragm high level of operating safety and long
More informationRound duct nozzle jet diffuser Model DSA-RR
Round duct nozzle jet diffuser Model DSA-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3
More informationR133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid
R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder
More informationDSL, DSH: Specially designed pressure limiter
Product data sheet 11.1 23.770 DSL, DSH: Specially designed pressure limiter How energy efficiency is improved Control and monitoring according to needs and with no auxiliary energy. Features Switching
More informationE 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm
Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features
More informationNikuni KTM Series Pumps
Nikuni KTM Series Pumps ( Micro Bubble Generator for DAF System ) Client : Project : Model : KTM2N- (SS34 Material) Doc. No. : Date : Revision No. : Japan Headquarters : 843-5, Kuji, Takatsu-Ku, Kawasaki-Shi,
More information2-Port Seat Valves with Flange, PN 16
4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic
More informationPressure relief valve DHV 725 set range: 0,2-10,0 bar
Pressure relief valve DHV 75 set range: 0, - 0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level
More information10.2. Basketball Single Post System
Basketball Basketball Single Post System The single-post basketball stand is made with oval aluminium profiles with a cross-section of 120 x 100 mm. The wall thickness of this robust apparatus is 4 to
More informationSafety relief valves Type SFV 20-25
Data sheet Safety relief valves Type SFV 20-25 SFV 20-25 are standard, back pressure dependent safety relief valves in angle-way execution, specially designed for protection of vessels and other components
More informationCOMMERCIAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet
For Door Heights To 8 (environmental separation) COMMERCIAL LOW PROFILE 8 Data Sheet STANDARD CONSTRUCTION 8 1/2 high x 13 1/2 deep 1/5 hp two speed motor(s) Factory installed fan speed/heat switch White
More informationPressure Reducing Valve DMV 755
Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to
More informationUNIK 5600/5700 Marine Certified Pressure Sensing Platform
GE Measurement & Control UNIK 5600/5700 Marine Certified Pressure Sensing Platform The new UNIK 5600/5700 carries marine certification for most zones on-board ship, as well as Intrinsically Safe certifications.
More informationLiquid level regulating valves Types PMFL / PMFH and SV
Data sheet Liquid level regulating valves Types / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant, a system comprising a liquid level regulating valve
More informationCALMO
---------------------------------------------------- Sound attenuator with recessed connection for rectangular ducts ---------------------------------------------------------------------- GENERAL is, due
More informationProcessMaster FEP610 Electromagnetic flowmeter
Change from one to two columns Data Sheet DS/FEP61-EN Rev. A ProcessMaster FEP61 Electromagnetic flowmeter The new flowmeter: The first choice for all industrial standard applications. Measurement made
More information50Hz. water solutions. O SerieS DGO DRO
Hz water solutions O SerieS DGO DRO D a t a b o o k l e t EN water solutions O SerieS DGO DRO Hz D a t a b o o k l e t O SERIES O Series General characteristics AISI stainless steel lifting and carrying
More informationOFFSHORE. Trasfor OFFSHORE
OFFSHORE Trasfor OFFSHORE 2 Trasfor I Offshore Introduction Trasfor s transformers for offshore applications ensure the highest performance level of reliability in any working condition. More than 40 skilled
More informationDNVGL-CP-0187 Edition March 2016
CLASS PROGRAMME Type approval DNVGL-CP-0187 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationNikuni KTM Series Pumps
Nikuni KTM Series Pumps ( Micro Bubble Generator for DAF System ) Client : Project : Model : KTM2F- (Cast Iron/SS material fittings) Date : Doc. No. : Revision No. : Japan Headquarters : 843-5, Kuji, Takatsu-Ku,
More information2-Port Seat Valves with Flange, PN 16
4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in
More informationPrewired position switches FA series
Prewired position switches Technical data Housing Made of metal, coated with baked epoxy powder 2 m wired cable with 5x0,5 mm 2 wires marked SEV and IMQ Protection degree: IP6 General data Ambient temperature:
More informationTightness controls TC 1 3 and TC 4
Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems
More informationCompressed Air Conditioning Catalog Chapter I
Compressed Air Conditioning Catalog Chapter I 2 Compressed Air Conditioning Welcome Welcome New technologies and materials, design innovations and the integration of bus-suitable electronics have opened
More informationMobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)
Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air Types: PE 200-TE PE 250-TE PE 300-TE Production status: F02 PE 250-TE with compressor control (optional equipment) General Medium
More informationR300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids
HELYON 5 Chemin du Jubin 69570 DARDILLY Tél. +33 (0)4 72 52 16 70 - Fax +33 (0)4 72 52 16 71 R300 Brass high pressure regulator, for compressed air, gas and liquids FEATURES Pressure regulator for inlet
More informationPressure switch, Differential pressure switch and Thermostat RT-E
Data sheet Pressure switch, Differential pressure switch and Thermostat RT-E The RT-E series consist of pressure and differential pressure switches as well as thermostats. The units are designed for industrial
More informationMonitoring device NTS 30
P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit
More informationDifferential Pressure Control Types MP 54, MP 55 and MP 55A
MAKING MODERN LIVING POSSIBLE Data sheet Differential Pressure Control Types MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure controls are used as safety switches to protect refrigeration
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationWorkshop Compressors CLASSIC Series
www.kaeser.com Workshop Compressors CLASSIC Series Displacement: 210 to 40 l/min Pressure: 10 bar What do you expect from your Classic workshop compressor? Quality results can be achieved only by using
More information2-port and 3-port valves PN 16
OEM 2-port valves VVP459.10-0.63 to VVP459.25-6.3 3-port valves VXP459.10-0.63 to VXP459.25-6.3 3-port valves with bypass VMP459.10-0.63 to VMP459.20-4 2-port valves VVP459.25-6.3 to VVP459.40-25 3-port
More information2-step solenoid valve Type ICLX
Data sheet 2-step solenoid valve ICLX 32-150 ICLX 2-step solenoid valves belong to the ICV family. ICLX are used in suction lines for the opening against high differential pressure, e.g. after hot gas
More informationPressure switches for air and water CS
Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the
More information2-step solenoid valve Type ICLX
Data sheet 2-step solenoid valve ICLX 32-150 ICLX 2-step solenoid valves belong to the ICV family. ICLX are used in suction lines to open against high differential pressure, e.g. after a hot gas defrost
More information