Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E

Size: px
Start display at page:

Download "Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E"

Transcription

1 AIRFIX EXPANSION VESSELS Flamco Airfix Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX AIRFIX -E Flamco Edition 2005 / EXP

2 Flamco Flamco offers you a wide choice in the field of expansion vessels for potable water installations The use of Airfix expansion vessels offers the user a number of important advantages. Airfix expansion vessels are through-flow vessels, meaning that they are specially constructed so that they regularly rinse themselves with fresh mains water. In this way, still, stagnant water, which is associated with the formation of detrimental bacteria, is eliminated from the equation. This fact improves the quality of the drinking water. By using the Airfix A and expansion vessels, you can also limit water wastage. AIRFIX A The Airfix A expansion vessel enlarged here is supplied with a synthetic flow divider. This flow divider can be fitted between the standard T-piece (not supplied with the vessel) and the Airfix A vessel. The Airfix A expansion vessel and T-piece assembly can be fitted in the cold-water installation of the boiler and through-flow is established. 2 USER AVANTAGES AIRFIX A AN AIRFIX Very easy to fit. Covered inside and out with an anti-corrosion coating, both in the water half and the nitrogen half. Neither the diaphragm nor the coating give off any dye, smell or taste to the water; both have been approved by CE and the VGW (in Germany). Can be used with any storage water heater. Can also be used in pressure boosting systems.

3 Airfix -E Pressure expansion tanks with exchangeable diaphragms, suitable for use in hot-water, pressure boosting and water- AIRFIX AIRFIX -E AIRFIX -E-B management systems. The Airfix -E is a solid, stable tank which is easy to fit. It is a through-flow tank with two flange connections which has an exchangeable butyl diaphragm. The high-quality material of which the diaphragm is constructed is your guarantee of low permeability (which means that your gas will not leak away) and if used correctly, renders permeability negligible. Airfix -E tanks are fitted standard with an electronic diaphragm-rupture sensor and an internally-coated steel through-flow flange. USER AVANTAGES AIRFIX -E Complete through-flow from the tank, free choice of flow direction. Low pressure loss. The standard diaphragm-rupture sensor can, if so desired, be configured for remote reading device. Simple installation and long service life. The Airfix -E diaphragms come with a VGW certificate. Whichever Airfix vessel I choose, I know in advance that I m fitting quality. Airfix vessels are solid and have clever technological solutions to improve the through-flow of the water. In practice, they are the best choice for the specialist! Ensure that the double system connection is directly connected with the main flow in the potable water installation. 3

4 Flamco Logical Airfix technology offers the user signi Without an expansion vessel for sanitary appliances, the safety-valve (inlet combination) will leak water every time water is heated causing water wastage on each occasion. This significantly heightens the chance of lasting leakage as a result of pollution or calcium deposits building up in the area of the valve seat. This kind of serious water loss can now be stemmed by using an Airfix A or Airfix expansion vessel. AIRFIX All Airfix A and Airfix vessels are white in colour. Both diaphragm and vessel coating are internationally approved for use in combination with drinking water, meeting the CE standards (2002/16/EC). A reliable clamp construction which damages neither the vessel nor the diaphragm while allowing conservation of the entire vessel surface, something which is unthinkable in welded vessels without flanges. Airfix vessels use a special T-piece (supplied) which aids through-flow with its internal divider to ensure full through-flow in the vessel. An AirfixControl is fitted between the vessel and T-piece, enabling the Airfix vessel to be de-pressurized for maintenance work without the need for the installation to be put out of commission. The vessel pre-pressure must be 0.2 bar lower than the pressure in the cold-water installation or the pressure on the other side of the pressure-reducing valve. irections on how to fit the Airfix pressure expansion vessel Airfix A or Airfix expansion vessels should always be used with a Prescor B boiler valve. The vessel must be mounted in the cold-water pipe, between the Prescor valve and boiler. Airfix A or 4

5 ficant advantages The Airfix -E expansion tank can be used in pressure boosting systems, on either the intake or compression sides of the pumps. These installations are intended to prevent excessively low feeding pressure and help prevent excessive pressure changes at low flow speeds. At the same time, they reduce the number of times the pressure-water assembly needs to be switched. The Airfix -E expansion tank offers the precise solution for this. AIRFIX -E Inspection port (from 600 litres above and below). Pressure gauge with self-sealing valve case and an Rp 3 /8 IN connection to the tank itself. iaphragm-rupture sensor, basic appliance, display with red LE indicating diaphragm rupture. Maximum permissible gas prepressure on delivery: 6 bars. Maximum working pressures 10 and 16 bar. Airfix -E tanks are coated green. iaphragm-rupture sensor including signal cable. The Airfix -E diaphragm expansion tank has a gas space between the tank wall and the exterior of the membrane, and a water space within the diaphragm. The configuration of the gas space depends on the operating characteristics and the required pressure. A pressure boost in the water space will compress the gas volume and fill the diaphragm, while a reduction in pressure will lead to draining of water. Should the pressure in the gas space reach the set water pressure in the installation, water will be drained from the connection pipe. In all operating conditions, water flows through the tank with a very low loss of pressure. Airfix -E-L Airfix -E-B ouble system connection with through-flow function. For use in hot-water, pressure boosting and water-management systems. Airfix -E ouble system connection the link with the connection pipe. For pressure boosting, potable household, processing or fireextinguishing installations. Single steel threaded connection (without through-flow function) and without electronic membrane-rupture sensor. All materials used in this tank are potable water quality. 5

6 Flamco Airfix A and Airfix expansion vessels As long as the flow divider is not used, the Airfix A expansion vessel will function as a non-through-flow vessel. The pressure expansion vessels, when used in boiler systems, must always meet the requirements of the water board. The maximum temperature in Airfix vessels is 70 C. Versions and dimensions Airfix and Airfix Control Versions and dimensions Airfix A Prepressure Capacity Max. operating Connection (male imensions in mm Weight Code number pressure thread) in bar in litres in bar Ø A in kg Airfix A / , Airfix A / , Airfix A / , Airfix A / , Airfix A / , Versions and dimensions Airfix and AirfixControl Pre- Capacity Max. Connection imensions Weight Code pressure operating (male in mm number pressure thread) in bar in litres in bar Ø A in kg Airfix / , Airfix / , Airfix / , Airfix / , Airfix / , AirfixControl A * ifferent pre-pressures available on request. A 6

7 Flamco Airfix -E, -E-L and -E-B expansion tanks Airfix -E and -E-B tanks from litres with a maximum operating pressure of 10 or 16 bars and a maximum temperature of 70 C. Airfix -E-L tanks from litres with a maximum operating pressure of 10 bar. Tanks with model approval in compliance with Council irective 97/23/EC. iaphragm-rupture sensor, Council irective 89/336/EC-compliant. Special execution (available on request) stainless steel through-flow flange (mat ) or a stainless steel mono-connection. If a mono-connection is fitted, the tank is no longer equipped with through-flow. Versions and dimensions Airfix -E Capacity imensions in mm Flanges Weight in kg Code number in litres Ø a e PN bar 16 bar 10 bar 16 bar Airfix -E N Airfix -E N Airfix -E N Airfix -E N Airfix -E N Airfix -E N Airfix -E N Airfix -E N Airfix -E N Airfix -E N Airfix -E N Airfix -E N Versions and dimensions Airfix -E-L Capacity imensions in mm Female-thread Weight in kg Code number in connection litres Ø e a ISO bar 10 bar Airfix -E-L G 1 1 / Airfix -E-L G 1 1 / Airfix -E-L G 1 1 / Airfix -E-L G 1 1 / Airfix -E-L G 1 1 / Airfix -E-L G 1 1 / Airfix -E-L G 1 1 / a e Accessories Airfix -E Codenummer Remote reading diaphragm-rupture e Versions and dimensions Airfix -E-B Capacity imensions in mm Female-thread Weight in kg Code number in connection litres Ø e ISO bar 16 bar 10 bar 16 bar Airfix -E-B G 1 1 / Airfix -E-B G 1 1 / Airfix -E-B G 1 1 / Airfix -E-B G 1 1 / Airfix -E-B G 1 1 / Airfix -E-B G 1 1 / Airfix -E-B G Airfix -E-B G Airfix -E-B G Airfix -E-B G 2 1 / Airfix -E-B G 2 1 / Airfix -E-B G 2 1 / NOTE: When selecting the pre-pressure and after-pressure, please ensure that the maximum efficiency is not exceeded (60%). a e 7

8 AIRFIX EXPANSION VESSELS AIRFIX A CONTENTS PAGE Flamco Advantages of Airfix vessels 2/3 Airfix technology means the best in through-flow 4/5 Tables 6/7 Flamco b.v. P.O. Box AC Gouda Industriestraat AC Gouda The Netherlands Tel.: Fax: info@flamco.nl AIRFIX On the C which accompanies this brochure, you will find plenty more information. AIRFIX -E Copyright Flamco b.v., Gouda, olland. No part of this publication may be reproduced in any way without explicit reference to the source. The data listed applies solely to Flamco products. Flamco b.v. is in no way liable for the misuse of the equipment or incorrect interpretation of the technical information contained herein. We reserve the right to make technical alterations. Flamco b.v. refers you further to its international sales and delivery conditions as drawn up by Orgalime S

Airfix Pressure expansion vessels for sanitary appliances and potable water systems

Airfix Pressure expansion vessels for sanitary appliances and potable water systems airfix expansion vessels Your reliable partner 4 Airfix Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX AIRFIX -E AIRFIX P Edition EXP 2009 Flamco offers you

More information

Expansion Vessels for Potable Installations

Expansion Vessels for Potable Installations 4. Expansion Vessels for Potable Installations Domestic installations lose millions of litres of potable water due to expansion water leaking from the vent and expansion pipe. Flamco s Airfix diaphragm

More information

Flexcon. Flamco. Flamco. Diaphragm pressure expansion vessels FLEXCON C 2-80 FLEXCON CE FLEXCON M FLEXCON V-B FLEXCON EXPANSION VESSELS

Flexcon. Flamco. Flamco. Diaphragm pressure expansion vessels FLEXCON C 2-80 FLEXCON CE FLEXCON M FLEXCON V-B FLEXCON EXPANSION VESSELS FLEXCON EXPANSION VESSELS Flexcon Diaphragm pressure expansion vessels FLEXCON C 2-80 FLEXCON CE 110 1000 FLEXCON M FLEXCON V-B 2005 edition / EXP Choose quality choose a Flexcon the choice of a satisfied

More information

Airfix D-E-B Installation and operating instructions

Airfix D-E-B Installation and operating instructions www.flamco.nt-rt.ru Airfix D-E-B Installation and operating instructions Dear Customer, With the Airfix D-E-B membrane expansion vessel you have acquired a Flamco quality product. This expansion vessel

More information

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps Airfix D-E 6442.eps GB Installation and operating instructions 1999, Exclusion of liability All operation and maintenance related technical information, data and instructions contained in these installation

More information

Accessories for Sanitary Installations

Accessories for Sanitary Installations 5. Accessories for Sanitary Installations Flamco s Prescor B safety valves protect potable water systems from exceeding the maximum design operating pressure. Once the set pressure has been reached the

More information

Flamco. Flamco. Flamco. Accessories for heating systems PRESCOR PRESCOR S FLEXCON THERMO-PRESSURE GAUGE FLEXFAST FLEXCONSOLE

Flamco. Flamco. Flamco. Accessories for heating systems PRESCOR PRESCOR S FLEXCON THERMO-PRESSURE GAUGE FLEXFAST FLEXCONSOLE HETING SYSTEM ESSORIES ccessories for heating systems PRESOR PRESOR S FLEXON THERMO-PRESSURE GUGE FLEXFST FLEXONSOLE 2005 Edition / EXP complete programme for the protection of Prescor safety valves are

More information

VESSELS. DIAPHRAGM OR BLADDER TANKS For expansion and pressure boosting applications. Temperature range : -10 to C* Operating pressure :

VESSELS. DIAPHRAGM OR BLADDER TANKS For expansion and pressure boosting applications. Temperature range : -10 to C* Operating pressure : operating limits Temperature range : -10 to + C* Operating pressure : to 20 bar* * according to models. VESSES IAPHRAGM OR BAER TANKS For expansion and pressure boosting applications AdVANTAGES APPICATIONS

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic

More information

Two-port valves, male threaded, PN25

Two-port valves, male threaded, PN25 4 379 Two-port valves, male threaded, PN25 VVG55... Two-port valves, externally threaded, PN25 Bronze Rg5 DN15... 25 mm (½"... 1") k vs 0.25... 6.3 m 3 /h Stroke 5.5 mm Suitable for type SQS35... or SQS65...

More information

Gas Pressure Regulator HON 502

Gas Pressure Regulator HON 502 Gas Pressure Regulator HON 502 Product information serving the gas industry worldwide Gas Pressure regulator HON 502 Application, Characteristics, Technical Data Application for offtake stations in gas

More information

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel OM006 Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel The operating and maintenance instructions contained within this package are for standard mild steel buffer vessels

More information

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X Calibration Hydraulic comparison test pump Models CPP1000-X, CPP1600-X WIKA data sheet CT 91.12 for further approvals see page 2 Applications Calibration service companies and service industry Maintenance

More information

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting Description AVP(-F) is a self-acting differential pressure controller primarily for use in district heating systems.

More information

3-port seat valves with externally threaded connection, PN 16

3-port seat valves with externally threaded connection, PN 16 4 463 Acvatix 3-port seat valves with externally threaded connection, PN 16 VXG41.. ronze CuSn5Zn5Pb2 valve body DN 15 50 k vs 1.6 40 m 3 /h Flat sealing connections with external thread G to ISO 228-1

More information

2-port and 3-port seat valves, PN16

2-port and 3-port seat valves, PN16 s 4 47 VVI47 VXI47 CVTIX 2-port and 3-port seat valves, PN6 with internally threaded connections VVI47.. VXI47.. ronze valve body CC49K (Rg5) DN 5...5 k vs 2.5...4 m 3 /h Internally threaded connections

More information

Pressure Independent Control Series

Pressure Independent Control Series Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single

More information

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014 Air Purge Unit Series: LSP-compact Type: EJG 2-2 (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014 Headquarters Sales Office BENELUX Intra-Automation GmbH B. V. Intra-Automation HTP

More information

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

Installation, Operation and Maintenance Instructions Buffer Vessel OM006 Installation, Operation and Maintenance Instructions Buffer Vessel OM006 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail: sales@gmsthermal.co.uk

More information

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28 Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) and balanced Type 2422 Valve Type 42-24 Type 42-28 Application Differential pressure regulators

More information

Self-supporting hot water high pressure cleaner on trailer Hudson 315

Self-supporting hot water high pressure cleaner on trailer Hudson 315 Self-supporting hot water high pressure cleaner on trailer Hudson 315 High pressure system mounted in a Waterkracht single-axle trailer, with flip top. The trailer is made of stainless steel top and galvanised

More information

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Data sheet Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Description AVPQ is a self-acting differential pressure and flow controller primarily for use in

More information

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L Calibration Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L WIKA data sheet CT 91.05 for further approvals see page 2 Applications Calibration service companies and service industry Calibrations

More information

Self-operated Pressure Regulators for special applications

Self-operated Pressure Regulators for special applications Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic

More information

Sealed Systems Altecnic Ltd - Caleffi group. Sealed Systems. Heating vessel sizing guide

Sealed Systems Altecnic Ltd - Caleffi group. Sealed Systems. Heating vessel sizing guide 1.25 Sealed Systems Sealed Systems Sealed primary central heating systems are the most commonly used form of heating system throughout Europe and the rest of the developed world. Sealed central heating

More information

Gas Pressure Regulator HON 300

Gas Pressure Regulator HON 300 Product information serving the gas industry worldwide Applications, characteristics, technical data Applications direct acting gas pressure regulator, for systems in accordance with DVGW working instruction

More information

System Pressure Manager Standard & System Pressure Manager Plus

System Pressure Manager Standard & System Pressure Manager Plus System Pressure Manager Standard & System Pressure Manager Plus Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,

More information

2-port and 3-port valves PN 16

2-port and 3-port valves PN 16 OEM 2-port valves VVP459.10-0.63 to VVP459.25-6.3 3-port valves VXP459.10-0.63 to VXP459.25-6.3 3-port valves with bypass VMP459.10-0.63 to VMP459.20-4 2-port valves VVP459.25-6.3 to VVP459.40-25 3-port

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25 Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating

More information

Two-port seat valves

Two-port seat valves 4 345 Two-port seat valves with flange, PN16 VVF45... Two-port seat valves with flange, PN16 Spheroidal cast iron GGG-40 DN50...150 mm k vs 19...300 m 3 /h Stroke 20 or 40 mm Can be equipped with actuators

More information

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Self-operated Regulators Accessories Differential Pressure and Flow Regulators Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application

More information

Air Reservoirs. 1st edition. This publication is not subject to any update service. New versions are available in INFORM at

Air Reservoirs. 1st edition. This publication is not subject to any update service. New versions are available in INFORM at 1st edition This publication is not subject to any update service. New versions are available in INFORM at www.wabco-auto.com 815 000 490 3 8150004903 c Copyright WABCO 2005 Vehicle Control Systems An

More information

Pressure reducing valves Index

Pressure reducing valves Index Index General information page Introduction 506 General introduction 507 for a steam plant 509 Product information BSP thread page Brass 510 ; BSP female thread 511 ; BSP male thread 513 Stainless steel

More information

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work? 94270 What is Tank Blanketing? blanketing systems are used to prevent the escape of liquid vapors into the atmosphere or to prevent moisture from entering a tank and contaminating its contents. A tank

More information

Safety Relief Valve HON 832

Safety Relief Valve HON 832 Safety Relief Valve HON 832 product information serving the gas industry worldwide Application, characteristics, technical data Application 2 As leak gas SRV with internal vent connection (function class

More information

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1 HANDBOOK Ed. 2017 DS-ED 01/2017 - ENG 1 CHAPTER 9 BURSTING DISC DEVICES IN SERIES 3070 SCOPE Use: protection against possible overpressure of the apparatuses listed below, with regard to the operating

More information

CAST IRON SAFETY VALVE TYPE 6301

CAST IRON SAFETY VALVE TYPE 6301 CHARACTERISTICS The 6301 safety valve is dedicated to protect the equipment from potential overpressure. This is an automatic device that closes when the pressure conditions are back to normal. It is a

More information

AVP-F. p setting range (bar) Code No. 003H6200

AVP-F. p setting range (bar) Code No. 003H6200 Data sheet Differential pressure controller (PN 16) AVP - return and flow mounting, adjustable setting AVP-F - return mounting, fixed setting Description The controller has a control valve, an actuator

More information

INDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS

INDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS IBAIONDO, HYDROPNEUMATIC TANKS IBAIONDO, INTRODUCTION Hydropneumatic tanks are designed to be used in potable water supply installations as a part of the pressure booster set in order to ensure the adequate

More information

Safety Shut-off Valve SSV

Safety Shut-off Valve SSV Safety Shut-off Valve SSV 8200-8300 < Accurate operation < Compact design < Easy maintenance Applications The safety shut-off valve is designed for use in gas distribution, and pressure regulation systems.

More information

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger OM008 Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger The operating and maintenance instructions contained within this package are for Pacific water/water

More information

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL Capital Controls Series 71V3000 The Series 71V3000 electrically-heated vaporizer automatically vaporizes and superheats liquid chlorine, sulfur dioxide or ammonia at a rate controlled by the gas feed system.

More information

Pressure Reducing Valve DMV 755

Pressure Reducing Valve DMV 755 Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to

More information

2-port seat valves PN25 with externally threaded connections

2-port seat valves PN25 with externally threaded connections 4 379 2-port seat valves PN25 with externally threaded connections VVG55.. Valve body bronze CC491K (Rg5) DN 15...25 (½...1 ") kvs 0.25...6.3 m3/h Stroke 5.5 mm Sets of ALG.. with threaded and ALS.. with

More information

Peak Pressure Indicator MSI-3

Peak Pressure Indicator MSI-3 Peak Pressure Indicator MSI-3 Operating Instructions Cylinder Pressure Monitoring Digital Pressure Indicator DPI No installation Ready to use High quality sensor Large memory Easy handling Cost effective.com

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

STAUFF Accumulators Accessories

STAUFF Accumulators Accessories Local Solutions For Individual Customers Worldwide STUFF ccumulators Clamps & Supports 28 Safety Blocks 30 Burst Discs 34 Fuse Discs 35 Replacement Back-up Bottles 36 Clamps & Supports ccumulator Clamps

More information

Tank Blanketing Pressure Regulators RHPS Series

Tank Blanketing Pressure Regulators RHPS Series www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22

More information

Installation, operation & maintenance manual - original version

Installation, operation & maintenance manual - original version Installation, operation & maintenance manual - original version AVK gate valves for water and wastewater Series 01, 02, 06, 12, 15, 18, 20, 26, 32, 33, 36, 38, 50, 55 and 636 COPYRIGHT AVK GROUP A/S 2018

More information

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301 THE HF-300 SERIES Operating and Service Manual Series includes all variants of HF-300/301 Issue A July 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 3.1. Spring Loaded...

More information

Booster Regulator/Air Tank

Booster Regulator/Air Tank Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed

More information

2-Port and 3-Port Seat Valves with Female Thread, PN16

2-Port and 3-Port Seat Valves with Female Thread, PN16 4 362 VVI4 VXI4 2-Port and 3-Port Seat Valves with Female Thread, PN6 VVI4... VXI4... ronze valve body CC49K (Rg5) DN5... DN50 k vs 2.5... 40 m 3 /h Female threaded connections Rp as to ISO 7/ Can be equipped

More information

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils 4 440 Three-port valves with flange, PN6 VXF4... Three-port valves with flange, PN6 Can be used as mixing or diverting valves Grey cast iron GG-25 DN5...50 mm k vs.9...300 m 3 /h Stroke 20 or 40 mm Can

More information

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance CVI Valve Line Exceeds the industry s highest standards for reliability and performance Available in the most standard models with the shortest lead times in the industry Exceptional quality every CVI

More information

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1 ATH 500 M Compact integrated drive Installation in any orientation Water or air cooled CE marked and ROHS compliant Heated version (MT) available for corrosive applicaitons. Pumping speed N 2 He H 2 Ar

More information

Instruction Manual Contact Pressure Vacuum Gauge

Instruction Manual Contact Pressure Vacuum Gauge MS10 Instruction Manual Contact Pressure Vacuum Gauge Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

Neotecha SAPRO - Tank Valve Type ST for aseptic sampling with bottles Installation, Operation and Maintenance Instruction

Neotecha SAPRO - Tank Valve Type ST for aseptic sampling with bottles Installation, Operation and Maintenance Instruction 7 Before installation these instructions must be fully read and understood 1.4 Illegal technical changes It is illegal to do mechanical changes of the design of the Sapro tank valve, or to use parts of

More information

Mainsboost Installation, Operation & Maintenance Instructions

Mainsboost Installation, Operation & Maintenance Instructions mainsboost Mainsboost Installation, Operation & Maintenance Instructions Please leave this instruction booklet with the home owner as it contains important guarantee, maintenance and safety information

More information

553 Series.

553 Series. 38467.03 www.caleffi.com Pre-adjustable filling units Copyright 01 Caleffi 3 Series Function The automatic filling valve is a device consisting of a pressure reducing valve with compensating seat, visual

More information

BERMAD Waterworks. Combination Air Valve. Air Valves Series. Typical Applications. Features & Benefits. Additional Features.

BERMAD Waterworks. Combination Air Valve. Air Valves Series. Typical Applications. Features & Benefits. Additional Features. BERMA Waterworks Combination Air Valve Model C7 BERMA C7 is a high quality combination air valve for a variety of water networks and operating conditions. It evacuates air during pipeline filling, allows

More information

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ] Technical data sheet C2..QP-.. For closed cold and warm water systems For modulating control of airhandling and heating systems on the water side Snap-assembly of the actuator overview DN [ ] Vnom [ l/h]

More information

SPIROVENT VACUUM DEGASSERS

SPIROVENT VACUUM DEGASSERS SPIROVENT VACUUM DEGASSERS S P I R O V E N T A I R S U P E R I O R FLUID AND GAS There are always a certain amount of gasses in a fluid, dependent on pressure and temperature. The British physicist William

More information

6301 TYPE CAST IRON SAFETY VALVES

6301 TYPE CAST IRON SAFETY VALVES Pressure (bar) 6301 TYPE CAST IRON SAFETY VALVES FEATURES The 6301 type safety valve is a device designed to protect installations against possible overpressure. It operates automatically and closes when

More information

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401 THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions 4059051/3 IM-P405-48 EMM Issue 3 KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.

More information

MAINTENANCE AND OPERATING MANUAL

MAINTENANCE AND OPERATING MANUAL MAINTENANCE AND OPERATING MANUAL Cyclone condensate separator Type ASA EN EN Maintenance and operating manual Purpose and appropriate use Dear Customer, thank you for choosing our product. In order to

More information

Pressure maintenance systems with compressors

Pressure maintenance systems with compressors Pressure maintenance systems with compressors Compresso Pressure maintenance systems with compressors Pressurisation & Water Quality alancing & Control Thermostatic Control ENGINEERING AVANTAGE Compresso

More information

KSB Delta Compact Type Series Booklet

KSB Delta Compact Type Series Booklet Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,

More information

Diaphragm Accumulators

Diaphragm Accumulators 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydro-pneumatic accumulators for storing fluids.

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

Flexvent floatvents: reliable and easy to mount

Flexvent floatvents: reliable and easy to mount floatvents: reliable and easy to mount The floatvents /80, /80 - /80, /20 and /40 are supplied together with a shut-off valve to facilitate mounting and removal. When the floatvent is unscrewed from the

More information

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves 4059051/1 IM-P405-48 AB Issue 1 KBV21i and KBV40i Air Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

SV60 Safety valves. for use with steam, gas and liquids

SV60 Safety valves. for use with steam, gas and liquids SV60 Safety valves for use with steam, gas and liquids Spirax Sarco safety valves - protecting people, plant and profit The SV60 spring loaded full lift safety valve range from Spirax Sarco has been designed

More information

Safety Shut-Off Valve HON 720

Safety Shut-Off Valve HON 720 Safety Shut-Off Valve HON 70 Product information serving the gas industry worldwide Application, Characteristics, Technical Data Application main safety device for gas pressure regulating stations suitable

More information

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN Original manual

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN Original manual Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN2 2016-02 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without

More information

WE SAY: REFILL PLEASE!

WE SAY: REFILL PLEASE! multicontrol autofill MCA WE SAY: REFILL PLEASE! MULTICONTROL AUTOFILL SOLO MCA-S Ver.03/208-en OPERATING PRINCIPLE Operating principle Make-up Losses within the system are mostly unavoidable. To ensure

More information

Desde1963. Válvulas Pilotadas. Proveedor Integral. la Industria

Desde1963. Válvulas Pilotadas. Proveedor Integral. la Industria esde96 Válvulas Pilotadas Proveedor Integral de Por Soluciones Aire para la Industria Otras válvulas de proceso Cuerpos de Bronce, hierro fundido y conexión bridada, para completar la gama de soluciones.

More information

Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34

Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34 Pressure Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34 WIKA data sheet DS 95.18 Applications Chemical/petrochemical industry, oil/gas industries

More information

Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels

Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels OM003 Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels The operating and maintenance instructions contained within this package are for standard storage vessels

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body Size : Ends : Min Temperature : Max Temperature : DN 40 to DN 300 Flanges R.F. PN10/16-10 C + 80 C Max Pressure : 16 Bars up to DN200 Specifications : Removable stainless steel filter Bolted bonnet with

More information

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV) Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV) IMI TA / Control valves / The pressure independent balancing and control valve ensures

More information

Function. Code Automatic filling units with pressure gauge connection Size 1/2 Code Automatic filling units with pressure gauge Size 1/2

Function. Code Automatic filling units with pressure gauge connection Size 1/2 Code Automatic filling units with pressure gauge Size 1/2 utomatic filling units series 55 cert. n ISO 9 5/5 G Replaces 5/ G unction he automatic filling unit is a device consisting of a pressure reducing valve with compensating seat, an inlet strainer, a shut-off

More information

ACCREDITED. Technical specifications series

ACCREDITED. Technical specifications series nti-pollution check valves 0-0-0-0-0 series REITE ISO 0 FM LEFFI 000/ G replaces dp 000/0G Function The anti-pollution check valve is a protective plumbing device capable of preventing the backflow of

More information

Pressure Regulating Valves. Models 44, 77 & 68 PS\ UL. Pressure Relief Valve. Dorot Fire Protection Division. Certification & compliance by design

Pressure Regulating Valves. Models 44, 77 & 68 PS\ UL. Pressure Relief Valve. Dorot Fire Protection Division. Certification & compliance by design Fire Protection Div. Dorot Fire Protection Division Models, & 6 PS\ UL Pressure Relief Valve Certification & compliance by design -PS\UL ANSI FCI - Class VI seat leakage class Fire tested to EN ISO 6-:6

More information

KSB Delta Compact Type Series Booklet

KSB Delta Compact Type Series Booklet Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,

More information

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER Table of contents 1 Security and safety measures... 5 1.1 General safety instructions... 5 1.2 Intended use... 5 1.3 Danger zones and residual

More information

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

BIMBAR INFLATABLE PACKERS AND ACCESSORIES BIMBAR INFLATABLE PACKERS AND ACCESSORIES Geopro supplies a complete range of inflatable packers in nine different diameters from 28 up to 170mm. All our packers made of BIMBAR rubber technology are reinforced

More information

AUTOMATIC HOSE TEST UNIT, TYPE SPU

AUTOMATIC HOSE TEST UNIT, TYPE SPU VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE

More information

RR 16 Commercial & Industrial Regulator

RR 16 Commercial & Industrial Regulator Gas RR 16 Commercial & Industrial Regulator Applications The RR 16 regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants, as well as for all installations

More information

Pressure Reducing Valve DMV 750 set range: bar

Pressure Reducing Valve DMV 750 set range: bar Pressure Reducing Valve DMV 750 set range:.0-6.0 bar Advantage pressure setting possible at any time, also during operation hermetically sealed by valve diaphragm high level of operating safety and long

More information

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03 Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections FEATURES GENERAL APPLICATION The RP03 provides protection from both backsiphonage and backpressure

More information

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2 Self-operated Pressure Regulator Pressure Reducing Valve Type M 44-2 Type M 44-2, connection G 1 4, K VS = 0.15 Type M 44-2, connection G 1, K VS = 6 Fig. 1 Type M 44-2 Pressure Reducing Valve Mounting

More information

HIGH FLOW HIGH PRESSURE PUMP type BMS

HIGH FLOW HIGH PRESSURE PUMP type BMS When you have to test objects on different locations within your workshop, the mobile pump system BMS gives you the possibility to test adequately on different sites. Through its wheels (or forklift pockets)

More information

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar EN - english Instructions for installation and operation Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar Dear customer, Thank you for deciding in favour of the METPOINT

More information

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998 Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

MAINTENANCE & ASSEMBLY INSTRUCTIONS FUSIBLE LINK. Inline Thermal Check Valve

MAINTENANCE & ASSEMBLY INSTRUCTIONS FUSIBLE LINK. Inline Thermal Check Valve MAINTENANCE & ASSEMBLY INSTRUCTIONS IOM-FL 12-16 ISO Registered Company FUSIBLE LINK Inline Thermal Check Valve MODEL FL-200 REFERENCE DATA: FL-200 Series Assembly Drawing No. A88-60200-00. INSTALLATION:

More information

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information