420 Mobile Piston Pump Design Code B

Size: px
Start display at page:

Download "420 Mobile Piston Pump Design Code B"

Transcription

1 42 Mobile Piston Pump Design Code B ADU41 ADU49 ADU62 ADU8

2 Introduction 42 Series Mobile Piston Pump Eaton s 42 Series mobile pumps are open circuit, axial piston designs with displacements of 41cc, 49cc, 62cc, and 8cc for operating speeds up to 2,65 rpm. They are available with a variety of control options to match their performance to a broad range of mobile applications. The highly efficient pump controls reduce cooling system requirements, allowing a smaller and less expensive design to be used. Or, cooling capacity can be kept the same and the flow capability of the system increased to improve performance. A strong, field-proven rotating group allows the pumps to handle pressures to 28 bar (4 psi) continuous and 32 bar (46 psi) intermittent with less maintenance cost. 42 Series pumps use a saddletype swashplate with steel-backed polymer bearings and a pressure lubrication passage to reduce wear and support internal loads. The swashplate is very stiff, which reduces deflection and allows even loading of the bearings to extend the unit s service life. The combination of high load capacity bearings and a stiff drive shaft help provide a pump B1 bearing life of 332 hours at rated mobile conditions, reducing operating costs and extending operating life. A single control piston is used to vary pump output. This design reduces the forces acting on the swashplate, resulting in reduced package size, which allows pump installation into tighter locations. In response to customer expectations and regulatory requirements, Eaton has designed the 42 Series pumps to operate at very low noise levels. A bimetal timing plate is used to improve pump filling characteristics which further reduces fluid-borne noise and extends pump life. Both SAE and ISO mounting flange configurations are available as well as SAE and ISO tube- and flangetype ports. Side- or end-ported models are available to facilitate plumbing and help fit the pump to machine space needs, as are multiple drain ports to allow many mounting orientations. Typical Applications Loader backhoes Vibratory cable plows Mining machinery Dump truck lifts Agriculture tractors Chemical applicator trucks Railroad equipment Container handling, all-terrain, and truck cranes Vibratory cable plows Mining machinery and tunnel boring equipment Utility boom, off-road dump, and refuse trucks Material handling trucks and rough terrain fork lifts Concrete and asphalt pavers Feller/bunchers, forwarders, and log loaders Crawler dozers Articulate haulers Mini-excavators Features and Benefits Long pump life Quiet pump operation Low installed and operating costs Reduced maintenance Flexibility in machine design Compact size saves space Design promotes leak-free system 2 EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

3 Table of Contents Model Codes Specifications and Performance Control Options Load Sense and Pressure Compensator Pressure Compensator Torque Control Cold Start Valve Performance ADU ADU ADU ADU Pump Installation B-mount Rear-ported B-mount Side-ported C-mount Rear-ported C-mount Side-ported Thru-Drive SAE A Option Thru-Drive SAE B Option Dual Shaft Seal Option Control Installation Load Sense and Pressure Compensator Pressure Compensator Torque Control Cold Start Valve External Manual Stroke Adjustment Input Shaft Options Center of Gravity Installation and Start-up EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 3

4 Model Codes 42 Mobile Piston Pump * Additional Settings Available by Request A D U 6 2 R 8 A B 1 A A 1 A B 1 C D B Pump Series ADU 42 Series Open Circuit Piston Pump Pump Displacement cm 3 /r [2.5 in 3 /r] cm 3 /r [3. in 3 /r] cm 3 /r [3.8 in 3 /r] 8 8. cm 3 /r [4.88 in 3 /r] 7 Input Shaft Rotation R Right Hand L Left Hand 8 9 Front Mount and Shaft 1 2 Bolt B, 22.2 mm (.875in.) Dia. Keyed Shaft 2 2 Bolt B, 25.4 mm (1.in.) Dia. Keyed Shaft 3 2 Bolt B, mm (.875in.) Dia. Tapered Keyed Shaft 5 2 Bolt B, 13 Tooth 16/32 Spline 8 2 Bolt B,15 Tooth 16/32 Spline 32 2/4 Bolt C, 14 Tooth 12/24 Spline 33 2/4 Bolt C, 31.8 mm (1.25in) Dia. Keyed Shaft 34 2 Bolt B, 15 Tooth 16/32 Sled Runner Spline 35 2 Bolt B, 14 Tooth 12/24 Spline 38 2/4 Bolt C, mm (1.25) Dia. Tapered Keyed Shaft 1 11 Main Ports Size & Location AA Rear Ports Suction - 2 (Code 61); Pressure - 1 (Code 61) AB Side Ports Suction - 2 (Code 61); Pressure - 1 (Code 61) AC Rear Ports Suction - 2 (Code 61) with M12 Threads; Pressure - 1 (Code 61) with M1 Threads. AD Side Ports Suction - 2 (Code 61) with M12 Threads; Pressure - 1 (Code 61) with M1 Threads. AE Rear Ports Suction - SAE O-Ring Port; Pressure - UN-2B SAE O-Ring Port (ADU41 & ADU49 only) AF Side Ports Suction - #24 SAE O-Ring; Pressure - #16 SAE O-Ring (ADU41 and ADU49 Only) AG Rear Ports Suction - M48 Metric O-Ring; Pressure - M33 Metric O-Ring (ADU41 & ADU49 Only) AH Side Ports Suction - M48 Metric O-Ring; Pressure - M33 Metric O-Ring (ADU41 & ADU49 Only) AK Rear Ports Suction - 2 (Code 61); Pressure - #16 SAE O-Ring (ADU62 Only) 12 Case Drain Ports 1 #12 SAE O-Ring - Top 2 #12 SAE O-Ring - Bottom 3 M27 x 2 O-Ring - Top 4 M27 O-Ring - Bottom 5 #12 SAE O-Ring - Left Side (Swash Sensor Boss) 6 G 3/4 (BSPP) - Top 13 Diagnostic Pressure Ports Not available on thru-drive units No Diagnostic Pressure Ports 1 #6 SAE O-Ring - Plugged (Rear Ports Only) 2 M14 Metric O-Ring - Plugged (Rear Ports Only) 3 #4 SAE O-Ring - Plugged (Side Ports Only) 4 M12 Metric O-Ring - Plugged (Side Ports Only) 14 Controller Type A Pressure Flow Compensator With #4 SAE O-Ring Load Sense Port B Pressure Flow Compensator With M12 Metric O-Ring Load Sense Port C Pressure Compensator Only E Pressure Flow Compensator With G 1/4 (BSPP) Load Sense Port H Pressure Flow Compensator With Torque Control #4 SAE O-Ring Load Sense Port J Pressure Flow Compensator With Torque Control M12 Metric O-Ring Load Sense Port K Pressure Compensator With Torque Control Pressure Compensator Setting (Tolerance on Setting)* bar [3-31 lbf/in 2 ] bar [35-36 lbf/in 2 ] bar [4-41 lbf/in 2 ] Items that are bold indicate preferred configuration. 4 EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

5 Model Codes 42 Mobile Piston Pump * Additional Settings Available by Request A D U 6 2 R 8 A B 1 A A 1 A B 1 C D B Flow Compensator Setting (Tolerance on Setting)* No Flow Compensator Setting bar [18-22 lbf/in 2 ] bar [33-37 lbf/in 2 ] 19 2 Torque Control Setting No Torque Control AA 4 Nm [35 in-lbs] (41,49) AB 51 Nm [45 in-lbs] (41,49) AC 62 Nm [55 in-lbs] (41,49,62) AD 73 Nm [65 in-lbs] (41,49,62,8) AE 85 Nm [75 in-lbs] (41,49,62,8) AF 96 Nm [85 in-lbs] (41,49,62,8) AG 17 Nm [95 in-lbs] (41,49,62,8) AH 119 Nm [15 in-lbs] (49,62,8) AJ 13 Nm [115 in-lbs] (49,62,8) AK 141 Nm [125 in-lbs] (49,62,8) AL 153 Nm [135 in-lbs] (62,8) AM 164 Nm [145 in-lbs] (62,8) AN 175 Nm [155 in-lbs] (62,8) AP 186 Nm [165 in-lbs] (62,8) AR 198 Nm [175 in-lbs] (62,8) AT 29 Nm [185 in-lbs] (62,8) AU 22 Nm [195 in-lbs] (8) Control Special Features Control Special Features A Bleed Down Orifice D 12V Cold Start Valve 23 Maximum Displacement Option* 1 Standard Displacement (As Given In Code Title) 2 External Manual Stroke Adjustment Auxiliary (Rear) Mount & Output Shaft No Auxiliary Mounting Features AB SAE A 2 Bolt, 11T 16/32 Spline AC SAE B 2 Bolt, 13T 16/32 Spline AD SAE B 2 Bolt, 15T 16/32 Spline AE SAE A 2 Bolt, 9T 16/32 Spline 26 Shaft Seal No Shaft Seal 1 Standard Polyacrylate Shaft Seal 2 Viton Shaft Seal 3 Double, Two-Way Shaft Seal, Viton With VHO Filter 4 Nitrile Shaft Seal 5 Single Viton Shaft Seal in 2/4 Bolt C Mount Pump Housing Not available on SAE B mount Pump Special Features No Special Features AA Auxiliary Mounting Cover Plate AB Swash Position Sensor AC Shaft Speed Sensor AD Modified End Cover, Corner Removed AE Support Studs (1/2-13 UNC-2B x (4.64) Long in Top Two End Cover/Housing Bolt Locations AG Swash Position Sensor and Shaft Speed Sensor 29 3 Paint No Paint CD Blue Primer 31 Identification/Packaging Standard Eaton Identification Box Packaging 32 Design Level B Second Design Items that are bold indicate preferred configuration. EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 5

6 Specifications and Performance General Performance Specifications Units ADU41 ADU49 ADU62 ADU8 Displacement cc/r (in 3 /r) 41. (2.5) 49.2 (3.) 62.3 (3.8) 8. (4.88) Weight Single Seal 1 kg (lbm) 22.9 (5.4) 22.9 (5.4) 23.8 (52.4) 24.2 (53.4) Dual Seal (53.1) 24.1 (53.1) 25. (55.1) 25.4 (56.1) Pressure Continuous bar (psi) 28 (46) 28 (46) 28 (46) 21 (35) Intermittent 2 32 (46) 32 (46) 32 (46) 23 (3335) Peak 3 35 (5) 35 (5) 35 (5) 25 (3625) Speed 4 At 1 bar abs ( psig) rpm At.85 bar abs (5 in.hg) At 2 bar abs (15 psig) N/A Max (standby) Min Power Max (theoretical) kw (hp) 5.7 (68.) 6.8 (81.5) 75.6 (11.3) 61.7 (82.7) Standby.98 (1.3).98 (1.3) 1.1 (1.5) 1.4 (1.9) Torque Max (theoretical) Nm (lb-ft) 183 (135) 219 (162) 278 (25) 268 (198) Bearing Life 5 At 14 bar (23 psi) B1 Hours 13,65 55,58 33,5 17,15 At 21 bar (345 psi) 26,83 14,38 8,67 4,44 At 28 bar (46 psi) 1,28 5,51 3,32 N/A Mass Moment of Inertia Nm-sec (lb-in-sec 2 ) (.288) (.288) (.43) (.517) 1 Standard SAE B non-through drive. 2 Less than 1% of duty cycle. 3 Momentary system pressure spikes only. 4 Ratings based on Flange ports. Note: Tube ports are not available on the 62cc and 8cc displacements. 5 Bearing life ratings at rated speed - 1 bar abs ( psig) inlet. Inlet Pressure, Case Pressure, and Operating Temperature Requirements Inlet Pressure Case Pressure Operating Temperature Maximum Maximum Minimum Maximum Rated Minimum Maximum Continuous Intermittent Peak Rated Temperature Intermittent bar abs (psig) bar abs (in. Hg) bar abs (psig) bar abs (psig) bar abs (psig) bar abs (psig) C ( F) C ( F) C ( F) 1. ().85 (5) 4.4 (5) 1.3 (5) 3.1 (3) 6.2 (75) 93 (2) -37 (-35) 14 (22) Hydraulic Fluids Recommended Minimum Max. Operating Maximum Maximum Viscosity Intermittent Temperature of Minimum Viscosity Range Continuous at Startup 93 C (2 F) Intermittent Fluid cst (SUS) cst (SUS) cst (SUS) cst (SUS) cst (SUS) Use antiwear hydraulic oil, 16 to 4 (8 to 188) 43 (1192) 21 (972) 1 (59) 6 (46) or automotive type crankcase oil (designations SC, SD, SE or SF) per SAE J183 FEB8 For more information, see Eaton publication 579. For operation on other alternative or environmentally friendly fluids, please contact your Eaton Representative. 6 EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

7 Control Options Load Sense and Pressure Compensator Load Sense and Pressure Compensator Control The pump will provide power matching of pump output to system load demand, maximizing efficiency and improving load metering characteristics of any directional control valve installed between the pump and the load. Load sensing ensures that the pump always provides only the amount of flow needed by the load. At the same time, the pump operating pressure adjusts to the actual load pressure plus a pressure differential required for the control action. When the system is not demanding power, the load sense control will operate in an energysaving stand-by mode. Typically, the differential pressure is that between the pressure inlet and service port of a proportionally controlled directional valve, or a load sensing directional control valve. See the model code on page 4 for differential pressure settings for load sensing. If the load pressure exceeds the system pressure setting, the pressure compensator de-strokes the pump. The load sensing line must be as short as possible and can also be used for remote control or unloading of the pump pressure. For remote control purposes, it is recommended that you contact your Eaton Representative for the correct configuration of the control. Warning: The pressure compensator may be adjusted beyond the rated pressure of the pump. When adjusting the pressure limiter, install a -35 bar (-5 psi) gage in the outlet gage port and limit the pressure setting to the continuous rated pressure for the pump displacement shown on page 6. Pressure Limit Settings The pressure compensator uses two springs to cover the full pressure range of the ADU pumps. The high pressure spring covers the range from 14 bar (25 psi) to 28 bar (46 psi). The low pressure spring is adjustable from minimum pressure through 14 bar (25 psi). Flow Compensator (Load Sense) Settings There are three springs used to cover the load sense adjustment range of this control. Typical Operating Curve F case drain K inlet gage port (optional) K outlet gage port (optional) B inlet To load Optional bleed-down orifice in Code A or B with control special feaure "A". ø,4 mm (.15 in.). Orifice is plugged for no bleed down in control Code A or B. C outlet Dynamic Response per SAE J745 (Using Swash Plate Position) Outlet Flow Q Outlet Pressure Response Recovery Load Sense (off stroke) (on stroke) Recovery msec msec msec ADU ADU ADU ADU P J load sense signal port EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 7

8 Control Options Pressure Compensator Pressure Compensator Control The pump will provide a continuously modulated flow to meet changing load demands at a pre-adjusted compensator pressure. At pressures below the compensator setting, the pump will operate at maximum displacement. See model code on page 4 for compensator pressure ranges. Warning: The pressure compensator may be adjusted beyond the rated pressure of the pump. When adjusting the pressure limiter, install a -35 bar (-5 psi) gage in the outlet gage port and limit the pressure setting to the continuous rated pressure for the pump displacement shown on page 6. Pressure Limit Settings The pressure compensator uses two springs to cover the full pressure range of the ADU pumps. The high pressure spring covers the range from 14 bar (25 psi) to 28 bar (46 psi). The low pressure spring is adjustable from minimum pressure through 14 bar (25 psi). F Case Drain K Inlet Gage Port K Outlet Gage Port Pressure Cut-off Characteristics of Pressure Compensator Control at 49 C (12 F), static conditions. Outlet Flow + + Q B Inlet To Load See Model Code on Page 4 for Spring (Pressure) Adjustment Ranges. C Outlet Outlet Pressure P Dynamic Response per SAE J745 (Using Swash Plate Position) Response Recovery (off stroke) (on stroke) msec msec ADU ADU ADU ADU EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

9 Control Options Torque Control Torque Control The 42 Torque Control limits the power input to the pump preventing the engine from stalling while also optimizing the use of the engine power. When combined with Pressure Compensator Control and/or Load Sense (refer to page 7) it will allow the 42 to remain inside the power envelope of the Pressure Flow curve. When the combination of pump flow and outlet pressure moves outside the envelope, the pump displacement will automatically be reduced. F Case Drain B Inlet See Page 7 for Pressure Compensator Control and Load Sense J Load Sense Signal Port This maximum setting is easily calculated using the following steps: 1. Select the 42 pump displacement you intend to use 2. Identify the available engine horsepower (HP) and speed (rpm) 3. Calculate the torque limit required by the system using the equations shown 4. Select the MAX torque setting from the table shown C Outlet To Load Torque = Horsepower (HP) x 6325 Torque = Horsepower (KW) x 955 (in-lbs) Engine RPM (Nm) Engine RPM Code Torque Setting 41CC 49CC 62CC 8CC AA 4 Nm (35 in-lbs) AB 51 Nm (45 in-lbs) AC 62 Nm (55 in-lbs) AD 73 Nm (65 in-lbs) AE 85 Nm (75 in-lbs) AF 96 Nm (85 in-lbs) AG* 17 Nm (95 in-lbs) AH 119 Nm (15 in-lbs) AJ 13 Nm (115 in-lbs) AK 141 Nm (125 in-lbs) AL 153 Nm (135 in-lbs) AM 164 Nm (145 in-lbs) AN 175 Nm (155 in-lbs) AP 186 Nm (165 in-lbs) AR 198 Nm (175 in-lbs) AT* 29 Nm (185 in-lbs) AU 22 Nm (195 in-lbs) * reference 62cc Torque (lbf-in) Flow (GPM) Power Curve* % 75% Torque Curve* % 75% with Torque Control Pressure (PSI) with Torque Control Full Flow Pressure for Torque Limit Setting Pressure (PSI) without Torque Control Pressure Limit Setting 62cc AT 62cc AG EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 9

10 Control Options Cold Start Valve Cold Start Valve The 42 Cold Start Valve reduces pump start-up torque by directing control pressure to the outlet. It is primarily used in cold weather applications and includes a 12 or 24 VDC directional control valve mounted between the pump housing and compensator. F Case Drain K Inlet Gage Port (Optional) B Inlet Optional Bleed-down Orifice in Code A or B with Control Special Feature "A". Ø,4 mm (.15 In.). Orifice is Plugged for No Bleed Down in Control Code A or B. J Load Sense Signal Port K Inlet Gage Port (Optional) C Outlet To Load 1 EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

11 Performance ADU41 Overall Efficiency Versus 49º C (12º F), Full Flow, and 1. bar ( psi) Inlet bar (22 psi) 2 bar (29 psi) Efficiency (%) bar (36 psi) 28 bar (4 psi) Overall Efficiency Versus 49º C (12º F), Full Flow, and 1. bar ( psi) Inlet bar (15 psi) 68 bar (1 psi) Efficiency (%) bar (5 psi) 5 bar (7 psi) EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 11

12 Performance ADU41 Input Power Versus 49º C (12º F), Full Flow, and 1. bar ( psi) Inlet Input Power, Kw (hp) 52 (7) 45 (6) 37.5 (5) 3 (4) 22.5 (3) 15 (2) 2 28 bar (4 psi) 25 bar (36 psi) 2 bar (29 psi) 15 bar (22 psi) 13 bar (15 psi) 7.5 (1) 5 bar (7 psi) Input Torque Versus 49º C (12º F), Full Flow, and 1. bar ( psi) Inlet 226 (2) 181 (16) 28 bar (4 psi) 25 bar (36 psi) Input Torque, Nm (in-lb) 136 (12) 9 (8) 45 (4) 28 bar (29 psi) 15 bar (22 psi) 13 bar (15 psi) 5 bar (7 psi) 68 bar (1 psi) 34 bar (5 psi) EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

13 Performance ADU41 Delivery and Case Flow Versus 49º C (12º F) 134 (35) 3.5 Main Flow, lpm (gpm) 115 (3) 95 (25) 76 (2) 57 (15) 28 (1) 25 bar (365 psi) 28 bar (4 psi) 28 bar (4 psi) (1.) Case Flow, lpm (gpm) 19 (5) (.5) 25 bar (365 psi) Input Torque and Case Flow 49º C (12º F) Input Torque and Case Flow 49º C (12º F) Input Torque, Nm (in-lb) 4.5 (4) 3.94 (35) 3.38 (3) 2.81 (25) 2.25 (2) 1.69 (15) 1.13 (1).56 (5) 2 bar (29 psi) 11 bar (16 psi) (1.) 3. (.75) 2..5(.5) 1..25(.25) Case Flow, lpm (gpm) Input Torque, Nm (in-lb) 5.5 (45) 45. (4) 39.4 (35) 33.8 (3) 28. (25) 22.5 (2) 16.9 (15) 11.3 (1) 5.6 (5) 28 bar (46 psi) Torque 15 bar (2175 psi) Torque 28 bar (46 psi) Case Flow 15 bar (2175 psi) Case Flow (2.) 6. (1.5) 14. (1.).5 2. (.5) Case Flow, lpm (gpm) EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 13

14 Performance ADU49 Overall Efficiency Versus 49º C (12º F), Full Flow, and 1. bar ( psi) Inlet Efficiency (%) bar (22 psi) 2 bar (29 psi) 25 bar (36 psi) 28 bar (4 psi) Overall Efficiency Versus 49º C (12º F), Full Flow, and 1. bar ( psi) Inlet Efficiency (%) bar (15 psi) 68 bar (1 psi) 5 bar (7 psi) 34 bar (5 psi) EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

15 Performance ADU49 Input Power Versus 49º C (12º F), Full Flow, and 1. bar ( psi) Inlet 6 (8) 52 (7) 45 (6) 28 bar (4 psi) 25 bar (36 psi) Input Power, Kw (hp) 37.5 (5) 3 (4) 22.5 (3) 15 (2) 2 bar (29 psi) 15 bar (22 psi) 13 bar (15 psi) 7.5 (1) 5 bar (7 psi) Input Torque Versus 49º C (12º F), Full Flow, and 1. bar ( psi) Inlet 271 (24) 226 (2) 28 bar (4 psi) 25 bar (36 psi) Input Torque, Nm (in-lb) 181 (16) 136 (12) 9 (8) 45 (4) 28 bar (29 psi) 15 bar (22 psi) 13 bar (15 psi) 5 bar (7 psi) 68 bar (1 psi) bar (5 psi) EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 15

16 Performance ADU49 Delivery and Case Flow Versus 49º C (12º F) Main Flow, lpm (gpm) 153 (4) 134 (35) 34 bar (5 psi) 115 (3) 28 bar (4 psi) 95 (25) 76 (2) 57 (15) 1 28 (1) 3.8 (1.) 28 bar (4 psi) 1.9 (.5) 19 (5) 34 bar (5 psi) Case Flow, lpm (gpm) Input Torque and Case Flow 49º C (12º F) Input Torque and Case Flow 49º C (12º F) Input Torque, Nm (in-lb) 5.6 (45) 4.5 (4) 3.94 (35) 3.38 (3) 2.81 (25) 2.25 (2) 1.69 (15) 1.13 (1).56 (5) 2 bar (29 psi) 11 bar (16 psi) (1.) 3. (.75) 2. (.5) 1. (.25) Case Flow, lpm (gpm) Input Torque, Nm (in-lb) 67.5 (6) bar (46 psi) Torque 56.3 (5) (4) bar 33.8 (3) (46 psi) Case Flow (1.5) (1.25) 15 bar (2175 psi) Case Flow 22.5 (2) 14. (1.) (.75) 11.3 (1) 15 bar (2175 psi) Torque.5 2. (.5) (.25) Case Flow, lpm (gpm) 16 EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

17 Performance ADU62 Overall Efficiency Versus 49º C (12º F), Full Flow, and 1. bar ( psi) Inlet bar (29 psi) 15 bar (22 psi) 25 bar (36 psi) bar (4 psi) Efficiency (%) Overall Efficiency Versus 49º C (12º F), Full Flow, and 1. bar ( psi) Inlet Efficiency (%) bar (15 psi) bar (1 psi) bar (7 psi) bar (25 psi) EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 17

18 Performance ADU62 Input Power Versus 49º C (12º F), Full Flow, and 1. bar ( psi) Inlet 82 (11) 74.5 (1) 28 bar (4 psi) Input Power, kw (hp) 67 (9) 6 (8) 52 (7) 45 (6) 37.5 (5) 3 (4) 22.5 (3) 15 (2) 7.5 (1) 25 bar (36 psi) 2 bar (29 psi) 15 bar (22 psi) 13 bar (15 psi) 25 bar (365 psi) Input Torque Versus 49º C (12º F), Full Flow, and 1. bar ( psi) Inlet 317 (28) 271 (24) 28 bar (4 psi) 25 bar (36 psi) Input Torque, Nm (in-lb) 226 (2) 181 (16) 136 (12) 9 (8) 2 bar (29 psi) 15 bar (22 psi) 13 bar (15 psi) 69 bar (1 psi) 45 (4) 34 bar (5 psi) EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

19 Performance ADU62 Delivery and Case Flow Versus 49º C (12º F) Main Flow, lpm (gpm) 191 (5) 172 (45) 153 (4) 134 (35) 115 (3) 95 (25) 76 (2) 57 (15) 25 bar (365 psi) 28 bar (4 psi) Case Flow, lpm (gpm) 28 (1) 28 bar (4 psi) 3.8 (1.) 19 (5) 1.9 (.5) 25 bar (365 psi) Input Torque and Case Flow 49º C (12º F) Input Torque and Case Flow 49º C (12º F) Input Torque, Nm (in-lb) 5.6 (45) 4.5 (4) 3.94 (35) 3.38 (3) 2.81 (25) 2.25 (2) 1.69 (15) 1.13 (1).56 (5) 2 bar (29 psi) 11 bar (16 psi) Case Flow, lpm (gpm) 14. (1.) (.75).5 2. (.5) (.25) Input Torque, Nm (in-lb) 67.5 (6) 56.3 (5) 45. (4) 28 bar (46 psi) Torque 33.8 (3) 28 bar (46 psi) Case Flow 6. (1.5) 5. (1.25) 15 bar (2175 psi) Case Flow 22.5 (2) 4. (1.) 3. (.75) 11.3 (1) 15 bar (2175 psi) Torque 2. (.5) 1. (.25) Case Flow, lpm (gpm) EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 19

20 Performance ADU8 Input Power Versus 49º C (12º F), Full Flow, and 1. bar ( psi) Inlet bar (25 psi) 138 bar (2 psi) 86 Efficiency (%) bar (3 psi) Overall Efficiency Versus 49º C (12º F), Full Flow, and 1. bar ( psi) Inlet bar (1 psi) bar (15 psi) Efficiency (%) bar (5 psi) EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

21 Performance ADU8 Input Power Versus 49º C (12º F), Full Flow, and 1. bar ( psi) Inlet 7 (93.9) 6 (8.5) 27 bar (3 psi) Input Power, kw (hp) 5 (67.1) 4 (53.6) 3 (4.2) 2 (26.8) 172 bar (25 psi) 138 bar (2 psi) 13 bar (15 psi) 67 bar (1 psi) 1 (13.4) 35 bar (5 psi) Input Torque Versus 49º C (12º F), Full Flow, and 1. bar ( psi) Inlet 35 (398) 3 (2655) Input Torque, Nm (lb-in) 25 (2213) 2 (177) 15 (1328) 1 (885) 27 bar (3 psi) 172 bar (25 psi) 138 bar (2 psi) 13 bar (15 psi) 67 bar (1 psi) 5 (443) 35 bar (5 psi) EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 21

22 Performance ADU8 Delivery and Case Flow Versus 49º C (12º F) 18 (47.6) 16 (42.3) 35 bar (5 psi) Main Flow, lpm (gpm) 14 (37.) 12 (31.7) 1 (26.4) 8 (21.1) 6 (15.9) 4 (1.6) 2 (5.3) 27 bar (3 psi) 27 bar (3 psi) 35 bar (5 psi) Case Flow, lpm (gpm) 1.5 (.4) 1. (.3).5 (.1) Input Torque and Case Flow 49º C (12º F) Input Torque and Case Flow 49º C (12º F) 8 (71) 6 (531) Input Torque, Nm (lb-in) 7 (62) 6 (53) 5 (44) 4 (35) 3 (27) 2 (18) 1 (9) 2 bar (3 psi) 2 bar (3 psi) 3 (.8) 2 (.5) 1 (.3) Case Flow, lpm (gpm) Input Torque, Nm (lb-in) 5 (443) 4 (354) 3 (266) 2 (177) 1 (89) 27 bar (3 psi) 27 bar (3 psi) 6 (1.6) 4 (1.1) 2 (.5) Case Flow, lpm (gpm) EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

23 Pump Installation B-mount / Rear-ported RH Rotation 72.6 ( 2.86) (Diagnostic Port) 69.1 ( 2.72) (Diagnostic Port) Top Case Drain 11.2 (4.34) 46 ( 1.81) 72.1 ( 2.84) (Case Drain) 2X 13.6 (.54) For Compensator Configuration See Separate Compensator Installation Drawing Suction Port A Pressure Port Optional Diagnostic A Port 38.1 (1.5) (1.62) X.5-13 UNC-2B.77 Min. -4X UNC-2B.57 Min. 191 ( 7.52) 2X 218 ( 8.58) Optional Case Drain 87.9 ( 3.46) 97.3 ( 3.83) For Shaft Configuration See Separate Shaft Installation Drawing 9.4 (.37) 5.1 (.2) Ø11.6 ( 4.) 2X Ø14.2 (.56) ( 5.75) ( 4.81) ( 3.12) (Case Drain) ( 2.84) ( 3.) (Case Drain) 74.7 ( 2.94) 77.5 ( 3.5) Bottom Case Drain View A A p. 22 LH Rotation P. 24 Pressure Port ( ) ( ) Ø ( ) [7.58] ( ) X ( ) ( ) Optional Diagnostic Port.81 [2.6] 25.3 [8.8] Suction Optional PortDiagnostic Port.81 [2.6] EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 23

24 Pump Installation B-mount / Side-ported Case Drain Top 11.1 ( 4.34) RH Rotation A 73.8 ( 2.91) 74.7 ( 2.94) For Compensator Configuration See Separate Compensator Installation Drawing 72.1 ( 2.84) (Case Drain) 2x 13.6 (.54) Optional Case Drain 46 ( 1.81) 21.3 (.84) A 53.1 ( 2.9) Optional Suction Port 44.5 ( 1.75) Pressure Port Optional Diagnostic Port X UNC-2B.57 Min. ( 8.34) -4X UNC-2B (Diagnostic.57 Min. Port) 24.9 ( 9.39) ( 9.49) 71.4 ( 2.81) 71.4 ( 2.81) 97.3 ( 3.83) 87.9 ( 3.46) 9.4 (.37) 5.1 (.2) 11.6 ( 4.) 2x Ø14.2 (.56) For Shaft Configuration See Separate Shaft Installation Drawing Bottom Case Drain ( 5.75) ( 4.81) 79.2 ( 3.12) (Case Drain) ( 2.84) ( 3.) (Case Drain) (Diagnostic Port) ( 9.9) ( 1.9) View A A Suction Port Suction Port LH Rotation 4X.5-13 UNC-2B.77 Min. 4X.5-13 UNC-2B.77 Min ( 8.59) ( 8.59) 24 EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

25 Pump Installation C-mount / Rear-ported Top Case Drain ( 4.84 ) RH Rotation 46 ( 1.81) 74.7 ( 2.94) For Compensator Configuration See Separate Compensator Installation Drawing 2x 15.4 (.61) Suction Port A A Pressure Port Optional Diagnostic 41.1 Port 38.1 ( 1.62) 23.7 ( 1.5) 4X.5-13 UNC-2B.77 Min. -4X UNC-2B.57 Min. Bottom Case Drain ( 8.2) 2x 23.7 ( 9.8) Optional Case Drain 13.1 ( 4.6) 11 ( 4.33) For Shaft Configuration See Separate Shaft Installation Drawing 12.4 (.49) 5.8 (.2) ( 4.5) 2x Ø17.5 (.69) ( 4.58) ( 7.2 ) 4x Ø14.33 (.564) ( 4.81) 79.2 ( 3.12) (Case Drain) ( 2.84) ( 3.) (Case Drain) 69.1 ( 2.72) (Diagnostic Port) 72.6 ( 2.86) (Diagnostic Port) Ø127. ( 5.) View A A P. 24 LH Rotation 5.8 (.2) Optional Diagnostic Port Pressure Port Suction Port (.49) ( 4.6) 23.7 ( 8.2) 2x [8.8] ( 9.8).81 [2.6] ] EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 25

26 Pump Installation C-mount / Side-ported RH Rotation A Optional Suction Port 21.3 (.84) A A Optional Suction Port 21.3 (.84) Case Drain Top ( 4.84) Case Drain Top 73.3 ( 2.89) ( 2.81) ( 2.89) ( 2.81) ( 2.81) ( 2.94) ( 2.81) 74.7 ( 2.94) Optional Diagnostic Port 46 ( 1.81) ( 2.84) 2x 15.4 For Compensator (.61) 2x 15.4 Configuration See Separate For Shaft (.61) Configuration Optional For Compensator Compensator Installation Drawing See Separate Shaft Diagnostic Configuration See Separate For Shaft Configuration Installation Drawing Compensator Installation Drawing See Separate Shaft Port Installation Drawing Pressure Port Pressure Port ( 4.84) Case Drain Left Case Drain Left 5.1 (.2) ( 4.5) 2x Ø A 44.5 (.69) ( 4.6 ) (.49) ( 2.9) ( 1.75) ( 8.84 ) ( 4.6 ) -4X ( 2.9) ( UNC-2B 1.75).57 Min. ( 8.84 ) -4X UNC-2B Min. ( 9.99) 251.2(Diagnostic Port) ( 9.99) ( 9.89) 11 Case Drain Bottom 251.2(Diagnostic Port) ( ) 11 Case Drain Bottom ( 4.33) (.49) 4x Ø14.33 (.564) 46 ( 1.81) ( 2.84) 5.1 (.2) ( 4.5) 2x Ø (.69( ) 4.58) ( 7.2) 4x Ø14.33 (.564) ( 4.81) 79.2 ( 3.12) (Case Drain) ( 2.84) ( 3.) (Case Drain) ( 4.58) ( 7.2) ( 4.81) 79.2 ( 3.12) (Case Drain) ( 2.84) ( 3.) (Case Drain) Ø127. (5.) Ø127. (5.) 264.1(Diagnostic Port) ( 1.4) (Diagnostic Port) ( 1.59) ( 1.4) ( 1.59) View A A LH Rotation Suction Port 4X.5-13 UNC-2B.77 Min. 4X.5-13 UNC-2B.77 Min ( EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

27 Pump Installation Thru-Drive SAE A Ø82.63 ±.2 (3.253±.1) 7.9 (.31) Groove to Accept an Cap as 568A Size 42 (1/16 X 3 1/4 ID) O-ring UNC-2B 19 (.75) Min 86.4 (3.4) 3x UNC-2A Thru (4.188) (6.8) ( 4.188) For Output Shaft Configuration See Separate Output Shaft Installation Drawing A Thru-Drive Cover Plate Installation 2X 15.5 (.61) (4.188) (4.188) Optional Mounting Position 9.5 (.38) (11.31) 3. (11.81) With Double Shaft Seal Output Shaft Installation 9T Spline Output Shaft Installation 11T Spline Maximum Torque 75 Nm (66 in-lbf) Maximum Torque 119 Nm (156 in-lbf) Ø16.54 (.651) 9 Tooth 3 Flat Root Side Fit 16/32 Class 5 Internal Spline per ANSI B92.1 Accepts 9 Tooth 3 Flat Root Side Fit 16/32 External Splines per SAE J498b Class 1 or ANSI B92.1 Class 5 with 31.8 (1.25) Extension From Mounting Flange Additional Units Drive by This Spline Must Not Require More Than 74.6 N m (55 Lbf ft) of Torque 31.8 (1.25) (11.31) 3. (11.31) With Double Shaft Seal and C-mount Ø19.33 (.761) 11 Tooth 3 Flat Root Side Fit 16/32 Class 1 Internal Spine per SAE J498B Accepts 11 Tooth 3 Flat Root Side Fit 16/32 External Splines per SAE J498B Class 1 or ANSI B92.1 Class 5 with 31.8 (1.25) Extension From Mounting Flange Additional Units Driven by This Spline Must Not Require More Than N m (88 Lbf ft) of Torque 31.8 (1.25) (11.31) 3. (11.31) With Double Shaft Seal and C-mount EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 27

28 Pump Installation Thru-Drive SAE B Ø11.68±.2 (4.3 ±.1) 1.4 Groove to Accept an (.41) as 568A Size 45 (1/16 X 4 ID) O-ring 4x.5-13 UNC-2B Thru 86.4 [ 3.4] [ 5.75] [ 6.8] [ 5.75] For Output Shaft Configuration See Separate Output Shaft Installation Drawing B Thru-Drive Cover Plate Installation* 2X 2.6 (.81) (5.75) (5.75) * Contact your Eaton Representative for this option. Output Shaft Installation 13T Spline 9.7 (.38) (11.31) 3. (11.81) With Double Shaft Seal and C-mount Output Shaft Installation 15T Spline Maximum Torque 29 Nm (185 in-lbf) Maximum Torque 337 Nm (2987 in-lbf) Ø22.5 (.886) 13 Tooth 3 Flat Root Side Fit 16/32 Class 1 Internal Spline Per SAE J498B Accepts 13 Tooth 3 Flat Root Side Fit 16/32 External Splines Per SAE J498B Class 1 or ANSI B92.1 Class 5 with 41.2 (1.62) Extension From Mounting Flange 41.2 [ 1.62] (11.31) 3. (11.81) With Double Shaft Seal and C-mount Ø25.5 (1.6) 15 Tooth 3 Flat Root Side Fit 16/32 Internal Spline per ASA B Accepts 15 Tooth 3 Flat Root Side Fit 16/32 External Splines per SAE J498B Class 1 or ANSI B92.1 Class 5 with 46 (1.81) Extension From Mounting Flange 46 ( 1.81) (11.31) 3. (11.81) With Double Shaft Seal and C-mount 28 EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

29 Pump Installation Dual Shaft Seal B-Mount Dual Shaft Seal* 5.7 (.22) C-Mount Dual Shaft Seal* Cross Section of Dual Shaft Seal Assembly Seal Leakage Drain (VHO Filter Optional) * Refer to C-Mount Pump installation drawings for port locations. EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 29

30 Control Installation Load Sense and Pressure Compensator Load Sense and Pressure Compensator 92.3 [ 3.63] 74.3 [ 2.93] Load Sense Port 69.9 [ 2.75] [ 5.75] [ 5.19] 18.5 [ 4.27 ] [ 6.79] [6.95] With Double Shaft Seal 3 EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

31 Control Installation Pressure Compensator Pressure Compensator [ 6.22] 16.2 [4.18] With Double Shaft Seal 93.5 [ 3.68] 71.4 [ 2.81] 13.7 [ 4.8] [ 4.64] EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 31

32 Control Installation Torque Control (2.94) Compensator/Control Not Shown For Clarity (5.85) (1.32) 32 EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

33 Control Installation Cold Start Valve 92.2 (3.63) (4.9) (2.92) Load Sense Port (3.8) (2.75) (6.5) (4.7) (5.58) (7.6) (6.22) (6.79) (6.79) With Double Shaft Seal Housing (3.68) With Double Shaft Seal Housing (3.68) (1.79) 12 VDC Flying Lead Coil Shown See Below For Options (3.8) (2.81) (5.39) (4.71) (5.95) Optional Connectors Deutsch Option Metri-pack 28 Option Metri-pack 15 Option EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 33

34 External Manual Stroke Adjustment Maximum Stroke Limiter 18 [.71 ] Max Displacement Torque 2±5 Lbf ft After Adjusting Max Displacement Max Displacement is Reduced By Approximately 5 to 6% Per Clockwise Turn 3.5 [.14 ] 25% of Max Displacement Compensator/Control Not Shown For Clarity [ 4.14 ] [ 7. ] 19.6 [ 7.5 ] With Double Seal Housing and C-mount 34 EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

35 Input Shaft Options 1 Code 2 Code Maximum Torque 29 Nm (185 in-lbf) Maximum Torque 337 Nm (2987 in-lbf) 41.3 (1.62) 24.6 (.97) 3 [.12 ] 6.31±.4 Key Width ( ) 46 (1.81) 28.6 (1.12) 3 [.12 ) 6.31±.4 Key Width ( ) ( ) ( ) Ø 22.21±.1 ( ) Ø ( ) 3 Code Code.248 Maximum Torque 29 Nm (185 in-lbf) Maximum Torque 37 Nm (2717 in-lbf) Section A-A 41.3 [ 1.62 ].969 A UNF-2A Ø (.8558) 13 Tooth 3º Flat Root Side Fit 16/32 Class 5 Spline per ANSI B92.1 (Modified).875 Fits 13 tooth 3º Flat Root Side Fit 16/32 Internal Splines per SAE J498b Class 1 or ANSI B92.1 Class 5 A [63] 125:1 [1.5:12] EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 35

36 Input Shaft Options 8 Code 32 Code Maximum Torque 397 Nm (3514 in-lbf) 46 [ 1.81 ] Maximum Torque 64 Nm (566 in-lbf) Ø (.988) 15 Tooth 3º Flat Root Side Fit 16/32 Class 5 Spline per ANSI B92.1 (Modified) Fits 15 tooth 3º Flat Root Side Fit 16/32 Internal Splines per SAE J498B Class 1 or ANSI B92.1 Class 5 Ø (1.2293) 14 Tooth 3 Flat Root Side Fit 12/24 Class 5 Spline per ANSI B92.1 (Modified) Fits 14 Tooth Flat Root Side Fit 12/24 Internal Splines per SAE J498B Class 1 or ANSI B92.1 Class 5 33 Code 34 Code Maximum Torque 45 Nm (398 in-lbf) Maximum Torque 397 Nm (3514 in-lbf) Ø [.988] 15 Tooth 3 Flat Root Side Fit 16/32 Class 5 Spline per ANSI B92.1 (Modified) 1/4-2 UNC-2B 16 (.63) R EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

37 Input Shaft Options 35 Code 38 Code Maximum Torque 64 Nm (566 in-lbf) Maximum Torque 45 Nm.3125 (398 in-lbf).169 Section A-A Ø (1.2293) 14 Tooth 3 Flat Root Side Fit 12/24 Class 5 Spline per ANSI B92.1 (Modified) Fits 14 Tooth Flat Root Side Fit 12/24 Internal Splines per SAE J498B Class 1 or ANSI B92.1 Class A A UNF-2a Ø3.99 Thru [.157] [63] 125:1 [1.5:12] EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 37

38 Center of Gravity L3 Lt L2 L1 L4 Rear Port Side Port Thru-Drive Length Dual Seal Lcg L3 L4 Lcg L3 L4 Lcg L3 L4 Lt Lds ADU (4.31) 9.6 (.38) 2.9 (.11) (4.51) 9.2 (.36) 2.4 (.1) (5.18) 8.2 (.32) 2.1 (.8) (11.31) 13. (.5) ADU (4.31) 9.6 (.38) 2.9 (.11) (4.51) 9.2 (.36) 2.4 (.1) (5.18) 8.2 (.32) 2.1 (.8) (11.31) 13. (.5) ADU (4.32) 9.4 (.37) 2.9 (.11) (4.52) 9. (.35) 2.4 (.1) (5.17) 8. (.31) 2.1 (.8) (11.31) 13. (.5) ADU (4.32) 9.4 (.37) 2.9 (.11) (4.52) 9. (.35) 2.4 (.1) (5.17) 8. (.31) 2.1 (.8) (11.31) 13. (.5) Dimensions in mm (in) Examples: Calculation L 1 and L 2 Tandem ADU62 Thru-drive with ADU41 Rear Ported L 1 = Lcg L 2 = Lt + Lcg 131.3mm (5.17 inches) 287.3mm mm = 396.9mm (15.6 inches) Tandem Dual Seal ADU49 Thru-drive with ADU49 Side Ported L 1 = Lcg + Lds 131.5mm + 13mm = 144.5mm (5.69 inches) L 2 = Lt + Lds + Lcg 287.3mm + 13mm mm = 415mm (16.34 inches) Tandem Pump Applications Eaton recommends that tandem pump applications be provided with additional support to limit overhung loading of the mounting flange. The thru-drive alternate attachment points on the rear flange may be used with a customer designed support. 38 EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29

39 Installation and Start-up Warning: Care should be taken that mechanical and hydraulic resonances are avoided in the application of the pump. Such resonances can seriously compromise the life and/or safe operation of the pump. Drive Data Mounting attitude should be horizontal using the appropriate case drain ports to ensure that the case remains full of fluid at all times. Consult your local Eaton Representative if a different arrangement is required. In those cases where geometric tolerances of mounting are critical, or where specific tolerance ranges are required and not specified, consult Eaton Engineering for specific limits. Direction of shaft rotation, viewed from the prime mover end, must be as indicated in the model designation on the pump either right hand (clockwise) or left hand (counterclockwise). Direct coaxial drive through a flexible coupling is recommended. If drives imposing radial shaft loads are considered, please consult your Eaton Representative. Start-up Procedure Make sure the reservoir and circuit are clean and free of dirt/debris prior to filling with hydraulic fluid. Fill the reservoir with filtered oil and fill to a level sufficient enough to prevent vortexing at the suction connection to pump inlet. It is good practice to clean the system by flushing and filtering, using an external slave pump. Caution: Before the pump is started, fill the case through the uppermost drain port with hydraulic fluid of the type to be used. The case drain line must be connected directly to the reservoir and must terminate below the oil level. Once the pump is started, it should prime within a few seconds. If the pump does not prime, check to make sure that there are no restrictions between the reservoir and the inlet to the pump, and that the pump is being rotated in the proper direction, and that there are no air leaks in the inlet line and connections. Also check to make sure that trapped air can escape at the pump outlet. After the pump is primed, tighten the loose outlet connections, then operate for five to ten minutes (unloaded) to remove all trapped air from the circuit. If the reservoir has a sight gage, make sure the fluid is clear not milky. Fluid Cleanliness The 42 Series pumps are rated in anti-wear petroleum fluids with a contamination level of 21/18/13 per ISO 466. Operation in fluids with levels more contaminated than this is not recommended. Fluids other than petroleum, severe service cycles, or temperature extremes are cause for adjustment of these codes. Please contact your Eaton Representative for specific duty cycle recommendation. Eaton 42 Series pumps, as with any variable displacement piston pumps, will operate with apparent satisfaction in fluids up to the rating specified here. Experience has shown however, that pump and hydraulic system life is not optimized with high fluid contamination levels (high ISO cleanliness codes). Proper fluid condition is essential for long and satisfac tory life of hydraulic components and systems. Hydraulic fluid must have the correct balance of cleanliness, materials, and additives for protection against wear of components, elevated viscosity and inclusion of air. Essential information on the correct methods for treating hydraulic fluid is included in Eaton publication 561 Eaton Guide to Systemic Contamination Control available from your local Eaton distributor. In this publication, filtration and cleanliness levels for extending the life of axial piston pumps and other system components are listed. Included is an excellent discussion of the selection of products needed to control fluid condition. EATON 42 Mobile Piston Pump Technical Manual E-PUPI-TM2-E3 September 29 39

40 Eaton Hydraulics Group USA Lone Oak Road Eden Prairie, MN USA Tel: Fax: Eaton Hydraulics Group Europe Route de la Longeraie Morges Switzerland Tel: +41 () Fax: +41 () Eaton Hydraulics Group Asia Pacific Eaton Building 4th Floor, No.3 Lane28 Linhong Rd. Changning District Shanghai 2335 China Tel: (+86 21) Fax: (+86 21) Eaton Corporation All Rights Reserved Printed in USA Document No. E-PUPI-TM2-E3 Supersedes E-PUPI-TM2-E2 September 29

420 Mobile Piston Pump Design Code B

420 Mobile Piston Pump Design Code B 42 Mobile Piston Pump Design Code B ADU41 ADU49 ADU62 ADU8 Introduction 42 Series Mobile Piston Pump Eaton s 42 Series mobile pumps are open circuit, axial piston designs with displacements of 41cc, 49cc,

More information

220 Mobile Piston Pump Catalog Design Code A AEC028

220 Mobile Piston Pump Catalog Design Code A AEC028 220 Mobile Piston Pump Catalog Design Code A AEC028 Introduction 220 Series Piston Pump Eaton s new 220 Series piston pump signifies a step change in the generation of hydraulic power. Utilizing the latest

More information

E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21

E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21 E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21 Table of Contents Introduction......................................................................................................

More information

PVQ 13 A2 R SE 1 S 20 C-11 D

PVQ 13 A2 R SE 1 S 20 C-11 D PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders ENGINEERING DT PV Piston Pumps Same Day Shipments of Units or Part Orders Interchangeable Parts Fully Tested w w w. F l u i D y n e F P. c o m Email:cs@FluiDyneFP.com Contents asic characteristics.........................................................................................

More information

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications Replaces: 04.95 Dual displacement motor 10VM Plug-in dual displacement motor 10VE for open and closed circuit applications Size 28-60 Series 5 Nominal pressure 280 bar Peak pressure 350 bar 10VM Contents

More information

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design Brueninghaus Hydromatik Series 1, for open circuits Axial piston - swashplate design, Back to back - design RE 93100/02.97 Sizes 60...260 Nominal Pressure up to 350 bar Peak Pressure up to 400 bar Preliminary

More information

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC Publ. 1 - EN0709 - A 01 / 2000 / 2500 / FB Replaces : 1 - EN 084 - B L25-10709 - 1 CONTENTS GENERAL CHARACTERISTICS T67GB T6GC - T6ZC T67GB

More information

OMS Technical Information. Versions OMS. Versions

OMS Technical Information. Versions OMS. Versions Versions Versions Mounting flange Shaft Port size European version US version Drain connection Check valve Main type designation Standard flange Cyl. 32 G 1/2 l Yes Yes Cyl. 1.25 in 7/8-14 UNF l Yes Yes

More information

Fixed Displacement Motor A4FM

Fixed Displacement Motor A4FM Fixed Displacement Motor 4FM RE 91 12/4. replaces: 3.95 and RE 91 1 for open and closed circuits Sizes 22...5 Series 1, Series 3 Nominal pressure up to bar Peak pressure up to 45 bar Index Features 1 Ordering

More information

Directional Controls

Directional Controls Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP

More information

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Displacement 12, , Maximum flow rate (at 1450 rpm) bar. 00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment

More information

OMS Technical Information Technical data

OMS Technical Information Technical data Technical data TECHNICAL DATA FOR OMS Type OMS OMS OMS OMS OMS OMS OMS OMS OMS OMSW OMSW OMSW OMSW OMSW OMSW OMSW OMSW OMSW OMSS OMSS OMSS OMSS OMSS OMSS OMSS OMSS OMSS Motor size 80 100 125 160 200 250

More information

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries HYDRAULIC APPLICATION Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries Special vehicles Plastic and rubber machinery etc. CONTENTS Specification

More information

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request www.atos.com Table TA60obs/E Axial piston pumps type PVPY- (-R, -) variable displacement, with mechanical controls obsolete components - availability on request PVPY are variable displacement axial piston

More information

PVK OPEN LOOP PUMPS. Bulletin E

PVK OPEN LOOP PUMPS. Bulletin E PVK OPEN LOOP PUMPS Bulletin 47025-E Table of Contents Performance Assurance page 3 Features and Benefits page 4-5 Specifications page 6 Pump Controls page 7 Table of Contents Curves Performance page 8

More information

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump Sauer Danfoss Series 90 Hydraulic Axial Piston Pump www.hydpump.com 90R030, 90R042, 90R055, 90R075, 90R100, 90R130, 90R180, 90R250 90L030, 90L042, 90L055, 90L075, 90L100, 90L130, 90L180, 90L250 Series

More information

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94 Vickers Flow Controls Flow Controls FN, F(C)G, FRG Released 6/94 685 Table of Contents FN03/06/10 Model Series Application Data...............................................................................

More information

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Fixed Displacement Pump KFA for commercial vehicles in open circuits RE 91 501/05.98 Replaces: 11.96 Fixed Displacement Pump KFA for commercial vehicles in open circuits Sizes 23...107 Series 6 Nominal pressure 300 bar Peak pressure 350 bar KFA List of contents Features

More information

Orbital Motors Type OMP X and OMR X

Orbital Motors Type OMP X and OMR X Technical Information Orbital Motors Type OMP X and OMR X powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev January 218 Major revision. 21 February 217 First edition. 11 2

More information

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm) Vickers Cartridge Valves Load Controls Screw In Cartridge Valves Pressures to 50 bar (5000 psi) Flows to 90 l/min (50 USgpm) Rev. 2/99 722 Contents MODEL DESCRIPTION TYP. APPLICATION PRESSURE bar (psi)

More information

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics. Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum

More information

Fixed Displacement Motor A4FM

Fixed Displacement Motor A4FM Industrial Hydraulics Electric Drives and Controls Linear Motion and ssembly echnologies Pneumatics Service utomation Mobile Hydraulics Fixed Displacement Motor 4FM RE 91 12/4. replaces: 3.95 and RE 91

More information

Axial piston pumps type PVC

Axial piston pumps type PVC www.atos.com Table TA16-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low noise

More information

Axial piston pumps type PVC

Axial piston pumps type PVC www.atos.com Table TA16SK-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low

More information

Fixed Displacement Plug-In Motor A2FE

Fixed Displacement Plug-In Motor A2FE www.phphyds.com Series 6, axial tapered piston, bent axis design for mounting in mechanical gearboxes Sizes 28...355 Nom. Pressure up to 400 bar Peak Pressure up to 450 bar he fixed displacement plug-in

More information

HYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL

HYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL HYDRAULIC OORS APPLICAION» Skid Steer Loaders» etal working machines» renchers» Augers» Agricultural machines» Road building machines» Special vehicles» ine machines» Woodworking and sawmill machinery»

More information

DENISON HYDRAULICS T6 industrial application

DENISON HYDRAULICS T6 industrial application DENISON HYDRAULICS T6 industrial application vane pumps - single, double, triple Publ. 1 - EN0700 - B 10 / 2000 / FB Replaces : 1 - EN0700 - A L13-10700 - 2 CONTENTS - T6 SERIES INDUSTRIAL APPLICATION

More information

PLD 03 T A CASAPPA S.p.A.

PLD 03 T A CASAPPA S.p.A. GEAR FLOW DIVIDERS INDEX Section Page GENERAL FEATURES... 3 GENERAL DATA... 5 FLOW EQUALIZER... 6 FLOW DIVIDERS... 8 TYPICAL CIRCUITS... 10 NOTES ABOUT COMPOSITION... 12 PORTS DIMENSIONS.... 14 GROUP DIMENSIONS...

More information

DENISON HYDRAULICS high performance hydraulic vane pumps single, double, triple T7 and T67 industrial application

DENISON HYDRAULICS high performance hydraulic vane pumps single, double, triple T7 and T67 industrial application Back to Content DENISON HYDRAULICS high performance hydraulic vane pumps single, double, triple T7 and T67 industrial application Publ. 1 - EN 079 - B 01 / 97 / 3000 / FB Replaces : 1 - EN 079 - A CONTENTS

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

Axial Piston Variable Pump A10V(S)O (US-Version)

Axial Piston Variable Pump A10V(S)O (US-Version) Axial Piston Variable Pump A1V()O (U-Version) RA-A 9271/3.12 1/52 Replaces: 12.9 Data sheet eries 31 ize NG18 ((A)A1VO) ize NG28 to 14 (A1VO) Nominal pressure 4 psi (28 bar) Maximum pressure 51 psi (35

More information

Variable Displacement Pump A10VO

Variable Displacement Pump A10VO Brueninghaus Hydromatik Variable Displacement Pump A1VO Series 5, open circuits, SAE-Version Axialpiston, swash plate design size 28 6 Nominal pressure 2 bar Peak pressure 315 bar RE 9273/4.96 replaces

More information

HYDRAULIC MOTORS MV APPLICATION GENERAL

HYDRAULIC MOTORS MV APPLICATION GENERAL HYDRAULIC V APPLICAION» Conveyors» etal working machines» Agriculture machines» Road building machines» ining machinery» Food industries» Special vehicles» Plastic and rubber machinery etc. CONENS Specification

More information

PVV Open Loop Pumps. Bulletin E

PVV Open Loop Pumps. Bulletin E PVV Open Loop Pumps Bulletin 47028-E Table of Contents Table of Contents Performance Assurance page 3 Features and Benefits 4-5 Specifications 6 Controls Single Pressure Compensator 7 Single Pressure Compensator

More information

OMS, OMT and OMV Orbital Motors. Technical Information

OMS, OMT and OMV Orbital Motors. Technical Information , OMT and OMV Orbital Motors Technical Information , OMT and OMV A Wide Range of Orbital Motors Revision History Table of Revisions Date Page Changed Rev ED Dimensions changed EF A Wide Range of Orbital

More information

DISC VALVE HYDRAULIC MOTORS

DISC VALVE HYDRAULIC MOTORS DISC VALVE HYDRAULIC CONTENTS Page Hydraulic otors Series S... 4 Hydraulic otors Series T... 25 Hydraulic otors Series V... 39 otor Special Features... 51 otors with Speed Sensor... 52 Application Calculation...

More information

Orbital Motors Type OMP, OMR and OMH. Technical Information

Orbital Motors Type OMP, OMR and OMH. Technical Information Orbital Motors Type OMP, OMR and OMH Technical Information OMP, OMR and OMH Contents Revision View Date Page Changed Revision Mar 26 Small updates B Jun 27 all Major revision with new lit-number (minus

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

Directional Controls

Directional Controls Vickers Directional Controls Lever Operator Directional Control Valves DG17S-8-**-10 DG17S4-10 **-50 NF D08/D10, ISO-4401-08/10 Released 5/94 681 able of Contents General Information..................................................................................

More information

OMS, OMT and OMV Orbital Motors. Technical Information

OMS, OMT and OMV Orbital Motors. Technical Information OMS, OMT and OMV Orbital Motors Technical Information OMS, OMT and OMV A Wide Range of Orbital Motors F300540.eps F300030.TIF A wide range of orbital motors Sauer-Danfoss is a world leader within production

More information

GEAR PUMPS. Displacement from 5 to 39 ccm Pressure up to 280 bar Speed from 400 to 3000 RPM

GEAR PUMPS. Displacement from 5 to 39 ccm Pressure up to 280 bar Speed from 400 to 3000 RPM Displacement from 5 to 39 ccm Pressure up to 280 bar Speed from 400 to 3000 PM GEA PUMPS TABE OF CONTENTS DESCIPTION......................................................................................................................

More information

No October, Eaton. Gear Pumps. Parts Information. Series 26 Model Single Gear Pumps

No October, Eaton. Gear Pumps. Parts Information. Series 26 Model Single Gear Pumps Eaton Gear Pumps No. 6-634 October, 1995 Parts Information Series 26 Model 26000 Single Gear Pumps Pump Parts Drawing Righthand (CW) pump rotation shown. 14b 17 11 4D 1 25 9 4A 10 4B 14a 40 Plug 3 7 13

More information

Proper Pump Installation Practices

Proper Pump Installation Practices Proper Pump Installation Practices 80-779, Rev. 10/08 There is a Reason Every Unit Comes With This Bright Orange Tag! Proper Alignment and Coupling Installation Do Not Drive Coupling Onto Shaft Pump Alignment

More information

PRESSURE COMPENSATORS TECNORD

PRESSURE COMPENSATORS TECNORD PRESSURE COMPENSATORS 2-way, Compensating / Reducing Valves GPM PSI LPM BAR MODEL CAVITY PAGE 8 3500 30 245 DF-CP2 7/8 14 UNF 60 16 3500 60 245 QC-CP2 Special 62 Typical Schematic Typical application for

More information

HIGH PRESSURE DRILLING FLUID PUMP

HIGH PRESSURE DRILLING FLUID PUMP 1 HDF 200/250-280 HIGH PRESSURE DRILLING FLUID PUMP Dynaset HDF pump gives great water power with small amount of water in relation to its size. As self-priming it is productive in hard environment. Small

More information

Target Cleanliness Worksheet. Systemic Contamination Control

Target Cleanliness Worksheet. Systemic Contamination Control Target Cleanliness Worksheet Systemic Contamination Control Target Cleanliness Worksheet 1. SET A TARGET Eaton Recommended Cleanliness Code Chart PUMPS

More information

Directional Control Valves Technical Information Model 1500

Directional Control Valves Technical Information Model 1500 Single spool monoblock valve. 26.4 l/min [7 US gal/min] maximum flow. 138 bar [2 psi] maximum pressure with relief. 27 bar [3 psi] maximum pressure without relief. Garden tractors, mowers, utility equipment,

More information

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998 Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal

More information

Pressure reducing valve, pilot operated, Model 3DR

Pressure reducing valve, pilot operated, Model 3DR RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features

More information

Controllers DR, DP, FR and DFR

Controllers DR, DP, FR and DFR Controllers DR, DP, FR and DFR RE 9060 Edition: 04.014 Replaces: 10.006 For variable pump A4VSO series 1 and 3 Open circuit Features Control of pressure and flow Remote controlled optional Pressure controller

More information

SDM to 8 sections monoblock valve D1WWDA02A

SDM to 8 sections monoblock valve D1WWDA02A SDM 1 SDM1 1 to 8 sections monoblock valve D1WWDA2A SDM1 Additional information This folder shows the product in the most standard configurations. Please contact Sales Dpt. for more detailed information

More information

SystemStak Valves. ISO4401 Size 02

SystemStak Valves. ISO4401 Size 02 SystemStak Valves ISO441 Size 2 Reduce System Space Requirements SystemStak valves make compact hydraulic systems in which specific function valves are sandwich mounted between a directional valve and

More information

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi) Vickers Flow Controls DG**-6 Series Stacking Valves ISO-441-8 (D6) Interface Flows to 34 l/min (9 USgpm) Pressure to 21 bar (3 psi) 5125./EN/598/A Introduction These stackable modules are designed for

More information

Orbital Motors OMS, OMT and OMV

Orbital Motors OMS, OMT and OMV MKING MODERN LIVING POSSIBLE Technical Information Orbital Motors OMS, OMT and OMV powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev February 216 Corrected Hardening specification

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

Dean Pump Self-Priming Chemical Process Pumps

Dean Pump Self-Priming Chemical Process Pumps Bulletin C 1.2.34.7 Dean Pump Self-Priming Chemical Process Pumps php Series HEAD CAPACITY RANGE CHARTS php Self Primer - 2 Pole 3500 RPM 500 CAPACITY M 3 /HR 2900 RPM 50 HERTZ 25 50 75 125 150 400 TOTAL

More information

Cover headline. Cover subheadline. Check Valves

Cover headline. Cover subheadline. Check Valves Check Valves Cover headline Direct and pilot operated check valve functions for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Cover subheadline EATON Screw-In Cartridge Valves E-VLSC-MC-E December

More information

Orbital Motors OMSW with brake nose

Orbital Motors OMSW with brake nose MAKING MODERN LIVING POSSIBLE Technical Information Orbital Motors OMSW with brake nose powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev October 214 Changed to Danfoss layout

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

Axial piston-variable motor A10VM Plug-in version A10VE

Axial piston-variable motor A10VM Plug-in version A10VE Electric Drives and Controls Hydraulics inear Motion and ssembly Technologies Pneumatics Service xial piston-variable motor 10VM Plug-in version 10VE R 91703/06.09 1/28 Replaces:11.07 Technical Data Sheet

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE L15 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE TAKE CONTROL Take control with Muncie Power Products L15 directional control valve. The L15 is constructed with high-grade, iron castings and nickel-plated

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to: LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are

More information

MAKING MODERN LIVING POSSIBLE. Technical Information. Orbital Motor VMP. powersolutions.danfoss.com

MAKING MODERN LIVING POSSIBLE. Technical Information. Orbital Motor VMP. powersolutions.danfoss.com MAKING MODERN LIVING POSSIBLE Technical Information Orbital Motor VMP powersolutions.danfoss.com Revision History Table of Revisions Date Changed Rev Feb 214 New dimension drawings. Converted to Danfoss

More information

SERVICE INSTRUCTIONS PVWJ A-FRAME PUMPS -011/-014/-022 FOR TYPE P-C AND P-K SOFT START PRESSURE COMPENSATING CONTROLS

SERVICE INSTRUCTIONS PVWJ A-FRAME PUMPS -011/-014/-022 FOR TYPE P-C AND P-K SOFT START PRESSURE COMPENSATING CONTROLS Bulletin 947639 SERVICE INSTRUCTIONS PVWJ A-FRAME PUMPS -011/-014/-022 FOR TYPE P-C AND P-K SOFT START PRESSURE COMPENSATING CONTROLS OILG0260 Figure 1. Typical Oilgear Type P-C and P-K Soft Start Controls

More information

6000SLX HYDRAULIC CRAWLER CRANE

6000SLX HYDRAULIC CRAWLER CRANE HYDRAULIC CRAWLER CRANE HYDRAULIC CRAWLER CRANE Contents Specifications 3-4 Symbols 4 Outline Winch Assingment 5 Dimensions & Main Specifications : Liftcrane 6 Dimensions & Main Specifications : Luffing

More information

No March, Eaton. Gear Pumps. Parts Information. Model Multiple Gear Pumps B2 Series

No March, Eaton. Gear Pumps. Parts Information. Model Multiple Gear Pumps B2 Series Eaton Gear Pumps No. 6-628 March, 1993 Parts Information Model 25380 Multiple Gear Pumps B2 Series Pump Parts Drawing 13 50 1 25 12 11 5 9 8 17 16 3 6 15 45 28 49 9 8 17 16 48 29 26 Item 2 Backplate see

More information

directional control valve series cv691

directional control valve series cv691 directional control valve series cv691 Contents Page 3 Page 4 Page 5 Page 6-7 Page 8 Page 9 Page 10 Page 11-12 General Information Technical Data Performance Curves Dimensions Relief Valve Advantages

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

Displacement. from 2 up to 6 sections balanced, unbalanced from 0.8 to 31 ccm FLOW DIVIDERS

Displacement. from 2 up to 6 sections balanced, unbalanced from 0.8 to 31 ccm FLOW DIVIDERS Displacement from 2 up to 6 sections balanced, unbalanced from 0.8 to 31 ccm FLOW DIVIDERS DP Catalogue of flow dividers DP TABLE OF CONTENTS GENERAL DESCRIPTION........................................................................................................

More information

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm) Vickers artridge Valves Logic Elements Screw-in artridge Valves Pressures to 9 bar ( psi) Flows to l/min (8 USgpm) Revised 9/98 7 ontents MODEL DESRIPTION TYPIL PPLITION PRESSURE bar (psi) RTED FLOW l/min

More information

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Copyright, 2005 GPM Hydraulic Consulting, Inc. Troubleshooting and Preventive Maintenance of Hydraulic Systems Learning to Read the Signs of Future System Failures Instructed by: Al Smiley & Alan Dellinger Copyright, 2005 GPM Hydraulic Consulting,

More information

Introduction INDEX. INTRODUCTION HSE

Introduction INDEX.  INTRODUCTION HSE Introduction INDEX SECTION PAGE INTRODUCTION ORDERING CODE GLOSSARY MOTOR OPTION TECHNICAL SE SE3 / SE5 SE7 / S7 SE9 / S9 SE12 / S12 SE14 / S14 SE14-2 / S14-2 SE17 / S17 SE17-2 / S17-2 SE21 / S21 SE21-2

More information

Inverse Proportional Pressure-Relief Cartridge, Size 10

Inverse Proportional Pressure-Relief Cartridge, Size 10 Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size

More information

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Standard Operating and Maintenance Instructions for Pumping System Model PS-150 Standard Operating and Maintenance Instructions for Pumping System Model PS-150 High Pressure Equipment Company, LLC 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075

More information

Full Range Pressure Compensating Variable Flow Control

Full Range Pressure Compensating Variable Flow Control Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever

More information

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21 Desiccant Air Breathers DBE Section 3: SCHROEDER INDUSTRIES ACCESSORIES 21 Reservoir Accessories A hydraulic systems reservoir can play a significant role in the ingression of contamination into the system.

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US Industrial Hydraulic Valves Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories Catalog HY14-2500/US Industrial Hydraulic Valves WARNING USR RSPONSIBILITY FAILUR OR IMPROPR

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 33100 and 33101 Hydrostatic Test Pumps 33100 DIMENSIONS: WEIGHT: PUMP: MOTOR: CONTROL: GAUGE: DISCHARGE HOSE: 16 (40cm) L x 22 (55cm) W x 18 (45cm) H 87 lbs., 39.5 kg Triplex

More information

Dual position solenoid valve Type ICSH 25-80

Dual position solenoid valve Type ICSH 25-80 Data sheet Dual position solenoid valve Type ICSH 25-80 ICSH dual position solenoid valve belongs to the ICV family and consists of an ICV housing, an ICS insert together with an ICSH top cover with 2

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional

More information

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features

More information

180 Series Rotary Shear Directional Control Valve

180 Series Rotary Shear Directional Control Valve 180 Series Rotary Shear Directional Control Valve Up to l 38 lpm, 10 US gpm l 700 bar, 10,000 psi Milwaukee, WI 53235, US el: +1 (414) 769-6400 sales-us@webtec.com St. Ives, Cambs. E27 3LZ, UK el: +44

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement Hydraulic Motor/Pump Fixed Displacement Specifications size F11-5 -6-10 -12-14 -19 Displacement [cm 3 /rev] 4.9 6.0 9.8 12.5 14.3 19.0 Operating pressure max intermittent 1) [bar] 420 420 max continuous

More information

-for information only- noncommittal. Axial Piston Variable Pump A10VSO RA / /24. Technical Data Sheet

-for information only- noncommittal. Axial Piston Variable Pump A10VSO RA / /24. Technical Data Sheet Electric Drives and Controls Hydraulics inear Motion and Assembly Technologies Pneumatics ervice Axial Piston Variable Pump A10VO Technical Data heet ize 71... 180 eries 32 Nominal pressure 4000 psi (280

More information

Orbital Motors Type VMP. Technical Information

Orbital Motors Type VMP. Technical Information Orbital Motors Type VMP Technical Information A Wide Range of Orbital Motors Revision View Date Page Changed Revision May 213 All First edition AA F31 245 A Wide Range of Orbital Motors Sauer-Danfoss is

More information

Air Amplifiers & SYSTEMS

Air Amplifiers & SYSTEMS Air Amplifiers & SYSTEMS We Accept VISA, MasterCard and American Express Air Amplifiers Point-of-Use Air Solutions Maximator air amplifiers are designed to boost plant air pressure or increase the supply

More information

6000SLX SL-N HYDRAULIC CRAWLER CRANE

6000SLX SL-N HYDRAULIC CRAWLER CRANE SL-N SL-N HYDRAULIC CRAWLER CRANE 1804 05H.EA292 SL-N Specifications Contents Specifications 3-4 Symbols 4 Outline Winch Assignment 5 Dimensions & Main Specifications : Liftcrane 6 Dimensions & Main Specifications

More information

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators 61 Series Pilots for Pilot-Operated Pressure Reducing Regulators June 2011 Introduction 61 Series pilots are used with Types 1098-EGR and EZL pressure reducing regulators. These pilots can also be integrally

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

3-Way Pressure-Reducing Cartridge, Size 2 4

3-Way Pressure-Reducing Cartridge, Size 2 4 -Way Pressure-Reducing Cartridge, Size 2 Q max = 2 l/min, p max = 25 bar Spool-type design, direct acting, with manual adjustment 1 Description Compact construction for cavity type AM /- UNF to Bucher

More information

SERVICE INSTRUCTIONS PVWJ B-FRAME PUMPS -025/-034/-046 FOR TYPE P-1NN/F/J/K AND P-LNN/F/J/K LOAD SENSING CONTROLS

SERVICE INSTRUCTIONS PVWJ B-FRAME PUMPS -025/-034/-046 FOR TYPE P-1NN/F/J/K AND P-LNN/F/J/K LOAD SENSING CONTROLS Bulletin 947637 SERVICE INSTRUCTIONS PVWJ B-FRAME PUMPS -025/-034/-046 FOR TYPE P-1NN/F/J/K AND P-LNN/F/J/K LOAD SENSING CONTROLS OILG0258 Figure 1. Typical Oilgear Type P-1NN/F/J/K and P-LNN/F/J/K Load

More information

Axial piston variable motor A10VM Plug-in version A10VE

Axial piston variable motor A10VM Plug-in version A10VE Electric Drives and Controls Hydraulics inear Motion and ssembly Technologies Pneumatics Service xial piston variable motor 10VM Plug-in version 10VE RE 91703/06.09 1/28 Replaces:09.07 Data sheet Series

More information

WORKHOLDING APPLICATION BOOKLET

WORKHOLDING APPLICATION BOOKLET WORKHOLDING APPLICATION BOOKLET Applications and advantages of using minibooster hydraulic pressure intensifiers MINIMUM SIZE MAXIMUM POWER B-GB Workholding 2018.04 1 of 20 2 of 20 B-GB Workholding 2018.04

More information