GC Accessories. Agilent Consumables. Agilent Instrument Specific Replacement Parts. SGE Replacement Parts by Instrument Vendor.

Size: px
Start display at page:

Download "GC Accessories. Agilent Consumables. Agilent Instrument Specific Replacement Parts. SGE Replacement Parts by Instrument Vendor."

Transcription

1 GC Accessories Agilent Consumables GC and GC/MS Maintenance Schedule Bulk GC Supplies Inlet Septa Inlet Liners Specialty Injection Liners Gold Seals for Split/Splitless Inlets Liner O-Rings Capillary Column Ferrules and Nuts Ultra Inert Press Fits Self Tightening GC Column Nut GC Chromatography Supplies Agilent Instrument Specific Replacement Parts 7890B/7890A/6890 GC Supplies Quick Pick 7890/6890/6850 Split/Splitless Inlet Supplies 7890 Multimode Inlet Supplies 7890/6890/6850 Flame Ionization Detector (FID) Supplies 7697A Headspace Sampler Supplies Mass Spectrometer Supplies Autosampler Syringes Agilent Intuvo Supplies SGE Replacement Parts by Instrument Vendor Agilent Shimadzu Thermo Scientific Gas Management Flow Meters Gas Leak Detectors Gas Cylinder Regulators Gas Purification Systems Agilent Gas Clean Filters In-Line Big Traps In-Line Standard Size Gas Traps Fittings & Connections Restek Swagelok Fittings Gas Management Accessories

2 Featured Product 380 NEW! Agilent Intuvo Supplies An innovative range of supplies and fittings makes Intuvo the most efficient, cost-effective, premium GC to own and operate. This specially-designed range of supplies includes: ferrule-free fittings, Guard Chip retention gap technology, and no-trim columns, that transform your GC experience. Intuvo Flow Chips are fitted with smart keys, meaning Intuvo knows exactly how to set itself up, whether for splitting, backflush, GC detectors, or mass spectrometry. Fast Guard Chip replacement makes troublesome column trimming and associated downtime a thing of the past Gaskets take the place of ferrules, providing easy leak-free face seal connections for columns and detectors of the Intuvo flow path. Intuvo columns are coated with industry proven chemistries in a revolutionary form factor. Smart keys enable immediate identification of the column configuration, temperature limits, and monitors usage. Direct heating can save you time, and improve productivity in half the bench footprint. The torque driver for column installation is mounted to the inside of your GC. GC Accessories

3 GC ACCESSORIES Agilent Parts & Supplies Maintenance Schedule GC and GC/MS Maintenance Schedule GC AND GC/MS MAINTENANCE SCHEDULE ITEM TYPICAL SCHEDULE ACTION/COMMENTS GAS MANAGEMENT Gas purifiers (carrier gas and detector gas) Every 6 to 12 months Replacement schedule is based on capacity and grade of gas. In general, replace nonindicating traps every 6 to 12 months or when indicating traps start to change color. Replace indicating traps when indicating material is starting to change color. Internal split vent trap Every 6 months* Replace to prevent material backing up into EPC control and to avoid costly repair. External split vent trap Every 6 months* Replace to prevent sample analytes from escaping into the laboratory environment. Flow meter calibration Every 1 to 2 years Re-calibrate electronic flow meters follow recommended schedule for the unit (shown on the calibration certificate). SAMPLE INTRODUCTION OF INLETS Syringes and/or syringe needles Every 3 months* Replace syringe if dirt is noticeable in the syringe. If it cannot be cleaned, if the plunger doesn t slide easily, or if clogged. Replace needle if septa wear is abnormal or the needle becomes clogged. Inlet liner Weekly* Check often. Replace when dirt is visible in the liner or if chromatography is degraded. Liner O-rings Monthly* Replace with every liner change. Inlet septum Daily* Check often. Replace when signs of deterioration are visible (gaping holes, fragments in inlet liner, poor chromatography, low column pressure, etc.) Inlet hardware Every 6 months Every year Check for leaks and clean. Check parts and replace when parts are worn, scratched, or broken. Inlet gold or stainless steel seal Monthly* For highest level of reproducibility, change inlet seal with every liner change, but minimally replace monthly or when scratched, corroded, or if there is build-up of non-volatile sample components. COLUMNS Front-end maintenance Weekly-monthly* Remove 1/2 to 1 m from the front of the column when experiencing chromatographic problems (peak tailing, decreased sensitivity, retention time changes, etc.). Replace inlet liner and septum, and clean inlet as necessary. Guard column may be useful for increasing column lifetime. Solvent rinse As needed Perform when chromatography degradation is due to column contamination. Only for bonded and cross-linked phases. Replacement As needed Replace when trimming and/or solvent rinsing no longer restore chromatographic performance. Ferrules As needed Replace when changing columns and inlet/detector parts. DETECTORS FID/NPD jets and collector As needed Clean when deposits are present. Replace when they become scratched, bent, or damaged, or when having difficulty lighting FID or keeping flame lit. NPD bead As needed Replace when signal drifts or there is a dramatic change in sensitivity. FID Every 6 months Measure hydrogen, air, and makeup gas flows. TCD As needed Thermally clean by "baking-out" when a wandering baseline, increased noise, or a change in response is present. Replace when thermal cleaning does not resolve the problem. ECD FPD Every 6 months or as needed Every 6 months or as needed Wipe test. Thermally clean by "baking out" when baseline is noise, or the output value is abnormally high. Replace when thermal cleaning does not resolve the problem. Measure hydrogen, air, and makeup gas flows. Clean/replace FPD windows and seals when detector sensitivity is reduced. NCD and SCD Every 3 months* Change pump oil, oil coalescing filter and chemical trap. MASS SELECTIVE DETECTORS Tune MSD As needed Keep plenty of PFTBS (P/N ) on hand. Check the calibration vial Every 6 months Vial can be refilled without venting the system. Replace the foreline pump oil Every 6 months Check the fluid weekly. Change when the fluid becomes discolored or every 6 months. Replace the diffusion pump fluid Every year or as needed Check the fluid weekly. Too little fluid will cause the pump to run at a higher temperature, resulting in degradation and loss of high vacuum. Change when the fluid is discolored or contains particulates. Clean the ion source As needed Clean when performance deteriorates to remove contamination and to restore the electrostatic properties of the ion lens system. Replace scratched parts to maintain optimal performance. *Schedule is an approximation of average usage requirements. Frequency may vary widely based upon application and sample type. 364 Chrom Tech your chromatography specialists

4 Agilent Parts & Supplies GC ACCESSORIES Agilent Bulk GC Supplies AGILENT BULK GC SUPPLIES PART NO DESCRIPTION QTY LINERS Ultra Inert Liner, low pressure drop, glass wool 100/pk Ultra Inert Liner splitless liner, single taper, no wool 100/pk Ultra Inert splitless liner, single taper, glass wool 100/pk Ultra Inert split liner, straight, glass wool 100/pk Single taper split liner, low pressure drop 100/pk Single taper splitless liner, no wool 100/pk Single taper splitless liner, glass wool 100/pk Double taper splitless liner, no wool 100/pk SEALS Certified gold plated seal kit, includes washer 10/pk O-RINGS Non-stick fluorocarbon O-ring for Flip Top 100/pk Certified non-stick fluorocarbon O-ring 100/pk SEPTA Non-stick BTO septa, 11 mm 400/pk Non-stick Advanced Green septa, 11 mm 400/pk SILTITE FERRULE BULK PACKS G Ferrules, Siltite, mm column 100/pk G Ferrules, Siltite, 0.32 mm column 100/pk G Ferrules, Siltite, 0.53 mm column 100/pk Agilent Inlet Septa Economical and convenient packaging, same great Agilent quality AGILENT INLET SEPTA FOR AGILENT GC SYSTEMS DIAMETER QTY NON-STICK BLEED TEMP OPTIMIZED PREMIUM NON-STICK SEPTA NON-STICK LONG LIFE NON-STICK ADVANCED GREEN ECONOMICAL GENERAL PURPOSE 11 mm 50/pk mm 100/pk mm 400/pk SUMMARY OF PREMIUM INLET SEPTA CHARACTERISTICS Bleed Lifetime Temp Limits to 400 C inj port to 350 C to 350 C to 350 C Premium Non-Stick Septa Proprietary plasma treatment prevents sticking and unnecessary inlet cleaning Innovative blister packaging each septum is clean and ready for use Center point guides the needle for easy penetration, less coring and longer life AGILENT CROSSLAB INLET SEPTA FOR OTHER GC SYSTEMS DIAMETER QTY NON-STICK BLEED TEMP OPTIMIZED PREMIUM NON-STICK SEPTA NON-STICK LONG LIFE NON-STICK ADVANCED GREEN ECONOMICAL GENERAL PURPOSE 17 mm 24/pk mm 48/pk for Shimadzu 50/pk for Shimadzu 100/pk Authorized Distributor

5 GC ACCESSORIES Agilent Parts & Supplies Agilent Inlet Liners Agilent Ultra Inert Inlet Liners AGILENT ULTRA INERT LINERS DESCRIPTION VOLUME (µl) ID (mm) EA 5/PK 25/PK 100/PK* SPLIT INLET LINERS Low pressure drop, Ultra Inert Liner w/glass wool Straight, Ultra Inert Liner with glass wool SPLITLESS INLET LINERS Single taper, Ultra Inert Liner Single taper, Ultra Inert Liner with glass wool Splitless, double taper Ultra Inert Liner, no wool Dimpled, splitless, Ultra Inert Liner Straight, Ultra Inert Liner Straight Ultra Inert Liner for SPME *The 100/pk is not in the Touchless packaging. O-rings must be purchased separately. TECH TIP Agilent s Ultra Inert GC liners are delivered in Touchless packaging with a certified, non-stick o-ring pre-installed. Now you can quickly and easily install the new, clean liner without searching for the o-ring pack or risking contamination from touching. Agilent Original Deactivation Split & Splitless Liners AGILENT ORIGINAL DEACTIVATION SPLIT & SPLITLESS LINERS DESCRIPTION VOLUME (µl) ID (mm) EA 5/PK 25/PK 100/PK SINGLE TAPER SPLIT LINERS Single taper glass wool, deactivated, low pressure drop Single taper, glass wool, deactivated SINGLE TAPER SPLITLESS LINERS Single taper, deactivated Single taper, inert i Single taper, glass wool, deactivated STRAIGHT SPLIT LINERS STRAIGHT SPLITLESS LINERS Straight, glass wool, non-deactivated Straight, deactivated, quartz Straight, non-deactivated, quartz Straight, non-deactivated FOCUS SPLIT LINERS Deactivated with glass wool Tapered, deactivated with glass wool DOUBLE TAPER SPLITLESS LINERS Double taper, deactivated DIRECT INLET SPLITLESS LINERS Chrom Tech your chromatography specialists Straight, non-deactivated (for gas samples, headspace, or purge & trap)

6 Agilent Parts & Supplies GC ACCESSORIES Agilent Specialty Injection Liners Agilent MultiMode Inlet Heavy Matrix Injection Liners AGILENT MULTIMODE INLET HEAVY MATRIX DESCRIPTION VOLUME (µl) ID (mm) EA 5/PK 25/PK DIMPLED Dimpled splitless single taper, deactivated ULTRA INERT DEACTIVATED DIMPLED LINERS Dimpled, splitless, Ultra Inert Liner MANUAL INJECTION SPME Straight, with cup (for manual injections) Straight split liner with cup, glass wool, and packing, SPME, Ultra Inert deactivation VOLATILES Volatiles Organic Analysis liner Agilent Programmed Temperature Vaporization (PTV) Liners AGILENT PROGRAMMED TEMPERATURE VAPORIZATION (PTV) LINERS DESCRIPTION VOLUME (µl) ID (mm) PART NO PTV LINERS PTV liner, single baffle, glass wool, deactivated PTV liner, single baffle, deactivated PTV liner, multi baffled, deactivated PTV liner, sintered glass, deactivated LINERS FOR HIGH TEMPERATURE PTV INLET, G3506A PTV liner, high temperature, quartz PTV liner, high temperature, borosilicate Agilent Programmed Temperature Vaporization (PTV) Liners AGILENT DIRECT CONNECT DESCRIPTION ID (mm) PART NO Direct Connect Liner, single taper, deact 4 G Dual taper direct connect liner, splitless, Agilent proprietary deactivation 4 G Direct Connect Liner, single taper, deact 4 G Agilent Gold Seals for Split/Splitless Inlets AGILENT SPLIT/SPLITLESS INLET SEALS DESCRIPTION EA 10/PK 50/PK Certified gold plated seal kit, includes washer Gold plated seal with cross* Stainless steel seal Ultra Inert gold seal & washer *Use with total flow rates above 200 ml/min Authorized Distributor

7 GC ACCESSORIES Agilent Parts & Supplies Agilent Liner O-Rings AGILENT LINER O-RINGS DESCRIPTION QTY PART NO Certified non-stick fluorocarbon O-ring 10/pk /pk Graphite O-ring for splitless liner 10/pk Graphite O-ring for split liner 10/pk Non-stick fluorocarbon liner O-ring for Flip Top 10/pk /pk High temperature PTV inlet liner fluorocarbon O-ring 10/pk TECH TIP Packaged for convenience and cleanliness in a novel dial package that delivers 1 clean o-ring at a time. Agilent Capillary Column Ferrules and Nuts AGILENT CAPILLARY COLUMN FERRULES FOR USE WITH THE MOST BRANDS OF COLUMN, INCLUDING DB AND HP COLUMNS (10/PK) COLUMN ID (mm) FITS AGILENT BRAND COLUMN SERIES FERRULE NOMINAL ID SHORT FERRULE GRAPHITE SHORT FERRULE VESPEL SHORT FERRULE 85% VESPEL/ 15% GRAPHITE PRE-CONDITIONED LONG FERRULE 85% GRAPHITE/ 15% VESPEL ULTIMETAL PLUS FLEXIBLE METAL FERRULE DB, HP G DB, HP G DB, HP G No hole CAPILLARY COLUMN FERRULES FOR USE WITH CP, VF AND SELECT COLUMNS CP, VF, Select CP, VF, Select CP, VF, Select CP, VF, Select CP-silica PLOT CP, VF, Select No hole AGILENT COLUMN NUTS DESCRIPTION SHORT NUTS Chrom Tech your chromatography specialists PART NO Universal column nut, 1/16" hex, 2/pk Blanking plug, finger tight style column nut, 2/pk High Temperature SimDis PTV inlet, 4 mm hex LONG NUTS MS interface column nut, female, (requires long ferrule) Column nut for long or long two-hole ferrules ACCESSORIES Open end wrench, 1/4" and 5/16" SELF TIGHTENING COLUMN NUT (USES SHORT FERRULE) Self Tightening Column nut, Inlet/Detector Self Tightening Column nut, MSD UltiMetal Plus Flexible Metal Ferrule Self Tightening Column Nut Grips capillary tubing for proper seal without over tightening Highly inert for your trace-level analysis Robust, leak-free column connection Leak-free seal, even at high temperatures Easy finger-tight design no retightening needed Use with short graphite/polyimide ferrules Available for the inlet, detector and the MS transfer line

8 Agilent Parts & Supplies GC ACCESSORIES Agilent Ultra Inert Press Fits In the past it was necessary to use press-fit connectors with specific dimensions to connect columns of those dimensions. The new universal design means that you no longer have to choose a specific column dimension for the Press Fit. The taper of the Ultra Inert Press Fits allows for multiple column dimensions. Modern press-fit connectors are "laser-milled" to provide highly reproducible taper angles throughout the length of the press-fit, ensuring an excellent seal. The press-fits are now treated with Agilent Ultra Inert deactivation to provide a robust and inert flow path. The new Ultra Inert Press Fit containers have batch certification of inertness, easier to use instructions, and improved packaging to ensure your product arrives intact Universal Press Fit Union DESCRIPTION QTY PART NO Resin, Capillary Sealing, 5 grams Dangerous Good ea Y-splitter, Ultra Inert, universal press fit ea Universal Press Fit Union, Ultra Inert, for mm 10/pk Y-splitter Step 1 Lightly scribe column with wafer cutter (p/n ) Step 2 Gently break column apart Step 3 Inspect column end for clean, smooth cut using magnifier (p/n ) Wipe end of column with isopropyl alcohol and lint free cloth. Step 4 Grasp column near end and insert column into Press Fit. Plush the two straight together firmly. Step 5 Inspect connection, using the magnifier. A brown ring completely around the end of the column indicates a leak free seal. A tug on the column/union will assure an accurate connection. Though not required, you may also install your capillary columns using polyimide sealing resin. Check union for leaks before and after thermal cycling. Authorized Distributor

9 GC ACCESSORIES Agilent Parts & Supplies Agilent Self Tightening GC Column Nut & GC Chromatography Supplies Maintain the validity of your results with Agilent GC connection supplies. UltiMetal Plus Flexible Metal Ferrule Grips capillary tubing for proper seal without over tightening Highly inert for your trace-level analysis Robust, leak-free column connection Column Installation Pre-Swaging Tools Optimize GC performance and reproducibility by ensuring a proper length of column into the fittings, time after time Available for Agilent GC models 7890 and 6890, for graphite or metal ferrules Self Tightening Column Nut Leak-free seal, even at high temperatures Easy finger-tight design no retightening needed Use with short graphite/ polyimide ferrules Available for the inlet, detector and the MS transfer line UltiMetal Plus Deactivated Metal Tubing and Valves UltiMetal Plus Deactivated Stainless Steel Transfer Lines and Capillary Tubing Improves peak shapes for active compounds Ensures your entire chromatographic solution is inert and corrosion resistant Provides high inertness performance Stainless steel transfer line tubing, capillary guard column and retention gap tubing available in 0.25, 0.32, and 0.53 mm ID UltiMetal Plus Ultimate Union/UltiMetal Plus Tee Deactivated with UltiMetal Plus Leak-free connection of guard columns or retention gaps Saves money by allowing you to replace columns less frequently Completes Inert Flow Path with UltiMetal Plus Flexible Metal Ferrules Self-Tightening Column Nut or Flexible Metal Ferrule: Which is right for your application? If you need Ease of use Inertness Compatibility with installed or older hardware A leak-free seal at high temperatures (above 350 C) Capillary Flow Technology Device connection Pre-swaging connections for precise height into fitting Re-use of the ferrule MS interface Self Tightening Column Nut with graphite/ polyimide ferrule UltiMetal Plus Flexible Metal ferrule 370 Chrom Tech your chromatography specialists

10 Agilent Parts & Supplies GC ACCESSORIES DESCRIPTION QTY PART NO UltiMetal Plus Flexible Metal Ferrule Self Tightening Column Nut The Self Tightening GC Column nut uses the short ferrule for both the inlet and MS UltiMetal Plus Ultimate Union/ UltiMetal Plus Tee Column Installation Pre-Swaging Tools For mm columns 10/pk G For 0.32 mm columns 10/pk G For mm columns 10/pk G Self Tightening Column nut, MSD ea Self Tightening Column nut, Inlet/Detector ea Short graphite/polyimide ferrules mm columns 0.32 mm columns 0.45 and 0.53 mm columns 10/pk 10/pk 10/pk Ultimate Union, deactivated ea G Inert Tee ea G Graphite ferrule ea G Metal ferrule ea G AGILENT ULTIMETAL PLUS DEACTIVATED STAINLESS STEEL TUBING AND FITTINGS DESCRIPTION QTY PART NO 1/16" x 1.0 mm UltiMetal Plus tubing, 10 m ea /8" x 2.1 mm UltiMetal Plus tubing, 10 m ea /4" x 4.3 mm UltiMetal Plus tubing, 5 m ea /16" UltiMetal Plus nuts, front and back ferrule set 10/pk /8" UltiMetal Plus nuts, front and back ferrule set 20/pk /4" UltiMetal Plus nuts, front and back ferrule set 20/pk /16" UltiMetal Plus Tee ea /8" UltiMetal Plus Tee ea /4" UltiMetal Plus Tee ea /16" UltiMetal Plus Union ea /8" UltiMetal Plus Union ea /4" UltiMetal Plus Union ea /16" Inert tube ID x 560 mm ea /16" Inert Valco nut 10/pk /16" Inert Valco tee ea /16" Inert Valco union ea /16" Inert Valco ferrule 10/pk AGILENT ULTIMETAL PLUS DEACTIVATED STAINLESS STEEL TRANSFER LINES, CAPILLARY TUBING, AND GUARD COLUMNS PRODUCT TYPE DESCRIPTION PART NO Transfer line 1/16" OD Guard columns Tubing UM Plus transfer line 2 m x 0.25 mm ID UM Plus transfer line 10 m x 0.25 mm ID UM Plus transfer line 2 m x 0.75 mm ID UM Plus transfer line 10 m x 0.75 mm ID UltiMetal Plus Guard Column 2 m x 0.25 mm UltiMetal Plus Guard Column 2 m x 0.53 mm UltiMetal Plus Guard Column 5 m x 0.53 mm UltiMetal Plus Guard Column 10 m x 0.53 mm UltiMetal Plus tubing 50 m x 0.25 mm ID UltiMetal Plus tubing 50 x 0.32 mm ID UltiMetal Plus tubing 50 m x 0.53 mm ID CP6571 CP6572 CP6573 CP6574 CP6575 CP6576 CP6577 CP6578 CP6579 CP6580 CP6581 The Agilent Self Tightening GC Column Nut eliminates the need for retightening once and for all Agilent Self Tightening GC Column Nut for Agilent inlet and detector Agilent Self Tightening GC Column Nut for Agilent MS transfer line. This unique, self-tightening stainless steel GC column nut delivers a tight connection without expensive upgrades or adaptors and gives you the advantages of: Reliable performance: An innovative spring-driven piston continuously presses against the short graphite/polyimide ferrule maintaining a leak-free seal even after hundreds of injections. Less wasted time: No need to retighten after repeated thermal cycles. Ease of use: Finger-tight design lets anyone in your lab make consistent connections reliably without tools. Authorized Distributor

11 GC ACCESSORIES Agilent Parts & Supplies Agilent 7890B/7890A/6890 GC Supplies Quick Pick AGILENT QUICK REFERENCE GUIDE DESCRIPTION PART NO COLUMN INSTALLATION SUPPLIES Universal column nut FERRULES, 10/PK FERRULE ID (mm) COLUMN ID (mm) Graphite , 0.2, 0.25, Graphite Vespel/Graphite , 0.2, Vespel/Graphite Vespel/Graphite , Column ferrule installation tool Diamond-tipped column cutting pencil INLET SEPTA 11 mm Non-Stick BTO septa, 50/pk mm Advanced green septa, 50/pk mm Long Life Inlet septa, 50/pk mm through hole septa, 24/pk mm Long Life Inlet septa, 50/pk High Pressure Merlin Microseal Merlin Microseal, seal only SPLIT/SPLITLESS INLET SUPPLIES Liner, split, straight, glass wool, non-deactivated Splitless, single taper, deactivated, 4 mm ID Liner, splitless, single-taper, glass wool, deactivated Split, single taper, low pressure drop, glass wool Non-Stick Fluorocarbon O-ring, 10/pk Non-Stick Fluorocarbon O-ring for Flip Top, 10/pk, 6890 only Gold plated seal kit COOL ON-COLUMN INLET SUPPLIES PCOC 530um Septum Nut G Spring INSERTS For 200 µm columns, 1 ring For 250 µm columns, 6 rings For 320 µm columns, 5 rings Inserts for capillary columns PACKED COLUMN INLET SUPPLIES O-ring, Fluorocarbon, 12/pk Ferrule, 1/4" Vespel /4" nut, brass, 10/pk Disposable glass liner, 170 µl internal volume AGILENT QUICK REFERENCE GUIDE DESCRIPTION PART NO FLAME IONIZATION DETECTOR (FID) SUPPLIES Igniter glow plug assembly Blanking plug, finger-tight style FID collector assembly G High-temperature jet, SimDis 0.018" ID tip G Jet, 0.011"/0.29 mm ID tip, capillary dedicated Jet, packed standard 0.018" ID tip FID flow measuring insert FID cleaning kit NITROGEN PHOSPHORUS DETECTOR (NPD) SUPPLIES NPD white ceramic bead assembly G NPD black ceramic bead assembly Jet, 0.011"/0.29 mm ID tip, capillary dedicated G Jet, 0.011" ID tip, capillary adaptable FID AND NPD ADAPTERS FID/NPD adapter for capillary column Ferrule, 1/4" Vespel µm, 1.0 mm ID graphite ferrule µm, 0.5 mm ID graphite ferrule /4" nut, brass THERMAL CONDUCTIVITY DETECTOR (TCD) SUPPLIES TCD Capillary Column Adapter G ELECTRON CAPTURE DETECTOR (ECD) SUPPLIES Micro ECD wipe test kit TOOLS GC Installation Kit with Gas Purifiers (no tools) 19199N GC Installation Kit with Tools (no gas purifiers) 19199M General laboratory tool kit Injection Port Cleaning Kit GAS MANAGEMENT SUPPLIES CGA 580, 125 PSI max (8.6 bar), He, Ar, N OT3 Trap OT3-2 Hydrocarbon S-Trap, 1/8" fittings Moisture S-trap, preconditioned, 1/8" fittings CAPILLARY FLOW TECHNOLOGY SUPPLIES Ultimate Union kit, deactivated G Internal nut G Swaging nut G Column storage fitting G Fused silica, deactivated, 0.15 mm x 1 m Fused silica, deactivated, 0.15 mm x 5 m Fused silica, deactivated, 0.15 mm x 10 m Ferrule, flexi inert 0.25mm col 10/pk G Ferrule, flexi, inert 0.32mm col 10/pk G Ferrule, flexi, inert 0.53mm col 10/pk G Chrom Tech your chromatography specialists

12 Agilent Parts & Supplies GC ACCESSORIES Agilent 7890/6890/6850 Split/Splitless Inlet Supplies AGILENT 7890/6890/6850 SPLIT/SPLITLESS INLET SUPPLIES ITEM DESCRIPTION QTY PART NO 1 Headspace septum retainer nut ea Septum retainer nut ea Strain relief septum nut ea HSP 2 11 mm Certified BTO septa 50/pk Insert Weldment Top insert weldment assembly, standard ea G Top insert assembly, valve ea G Insert Weldment S/SL insert weldment; Used with large charcoal canister type filter, for 6890/6850 S/SL insert assembly for G1540A with valved system option; Uses the large charcoal canister split vent filter, for 6890/6850 Similar to G except carrier lines separated for interface to valved systems of a G1540A instrument ea G ea G ea G Original standard EPC using 1/4" split vent filter ea G Similar to G except allows insertion of 1/4" chemical filters to clean carrier gas for ECD operation ea G Insert Weldment Standard manual pneumatics ea Certified non-stick fluorocarbon O-ring 10/pk Graphite O-ring for split liner 10/pk Graphite O-ring for splitless liner 10/pk Non-stick fluorocarbon liner O-ring for Flip Top 10/pk Split vent rap kit ea G Repl cartridge (2) cartridges and (4) O-rings ea G Split vent trap Pm kit (1) cartridge & (2) O-rings ea Retaining nut ea G Stainless steel seal ea Certified gold plated seal kit, includes washer ea Gold plated seal with cross ea Washers, OD 12/pk Reducing nut ea Insulation kit, 3 pieces ea Lower insulation cover ea Ferrules (see pg 368) 13 Universal column nut 2/pk column nut 2/pk Split/splitless septum nut angled wrench ea Authorized Distributor

13 GC ACCESSORIES Agilent Parts & Supplies Agilent 7890 Multimode Inlet Supplies AGILENT MULTIMODE INLET BODY ITEM DESCRIPTION PART NO 1 Merlin cap Merlin Microseal Septum retainer nut mm Certified BTO septa 50/pk, for more septa, turn to page Top insert assembly, standard G Certified non-stick fluorocarbon O-ring Dimpled splitless single taper, deactivated Column nut adapter G Foil (LN 2 only) 10 Multimode Inlet insulation 11 Ferrule, for complete offering of ferrules, turn to page Agilent 7890/6890/6850 Flame Ionization Detector (FID) Supplies AGILENT 7890/6890/6850 FLAME IONIZATION DETECTOR (FID) SUPPLIES ITEM DESCRIPTION QTY PART NO 3 PTFE chimney (optional) ea FID collector assembly ea G FID collector cleaning brush 2/pk FID retainer nut wrench 5880, 5890, 6890 ea /4" nut driver for FID jet, drilled shaft ea Collector nut ea Spring washer 10/pk Igniter castle ea Hastelloy igniter castle (optional) ea Collector insulator ea G Collector body ea G Hastelloy collector body ea G FID igniter cable for 6890/6850 only ea G Collector mount 10 Silicone gaskets, 0.890" OD/0.709" ID 12/pk Igniter glow plug assembly ea FID igniter cable, 7890A only ea G AGILENT FID JETS DESCRIPTION JET TIP ID LENGTH PART NO JETS FOR CAPILLARY OPTIMIZED FITTINGS G Capillary 0.011" (0.29 mm) 42.8 mm G Capillary Optimized for simulated distillation 0.018" (0.47 mm) 42.8 mm G G JETS FOR ADAPTABLE FITTINGS Capillary 0.011" (0.29 mm) 61.5 mm Capillary Optimized for simulated distillation 0.018" (0.47 mm) 61.5 mm Packed 0.018" (0.46 mm) 63.5 mm Packed, wide-bore Use w/high-bleed applications 0.030" (0.76 mm) 63.5 mm Chrom Tech your chromatography specialists

14 Agilent Parts & Supplies GC ACCESSORIES Agilent 7697A Headspace Sampler Supplies AGILENT 7697A HEADSPACE REPLACEMENT PARTS AND SUPPLIES DESCRIPTION PART NO Tray vial racks G Vial rack label G Universal/external split vent trap with 3 cartridges, 1/8" Swagelok fitting Leak test kit Includes instruction sheet, no-hole ferrule, 1/8" nylon tube fitting plug, headspace leak test vial, 1/16" stainless steel ZDV plug, 11 mm low bleed septa (5/pk) RDT-1020 G A Sample Probe, Deactivated G Sample probe, deactivated SN 2000 G SAMPLING LOOPS, SN 2000 DESCRIPTION SN 1030 SN 2000 Sample loop, Headspace ml, inert G G Sample loop, Headspace 0.05 ml, inert G G Sample loop, Headspace 0.10 ml, inert G G Sample loop, Headspace 0.50 ml, inert G G Sample loop, Headspace 1.00 ml, inert G G Sample loop, Headspace 3.00 ml, inert G G Sample loop, Headspace 5.00 ml, inert G G CERTIFIED SAMPLE LOOPS* Certified sample loop, 1.00 ml G Certified sample loop, 3.00 ml G VIALS & CAPS FOR 7697A DESCRIPTION QTY PART NO Vial kit 20 ml Headspace crimp top, flat bottom vials, silver aluminum onepiece crime caps with safety feature, PTFE/white silicone septa 100/pk Headspace crimp top, flat bottom vials, 10 ml 100/pk Headspace crimp top, flat bottom vials, 20 ml 100/pk Silver aluminum crimp caps with 20 mm, PTFE/silicone septa 100/pk mm electronic crimper w/lithium battery ea Ergonomic manual crimper for 20 mm caps ea *Certified sample loops are validated by Micro Precision Calibration, Inc and come with a calibration certificate. Loops can be recertified yearly by contacting Micro Precision directly at +1 (530) A Headspace Sampler Authorized Distributor

15 GC ACCESSORIES Agilent Parts & Supplies Agilent Mass Spectrometer Supplies AGILENT ELECTRON IMPACT (EI) ION SOURCE ITEM DESCRIPTION SS SOURCE INERT SOURCE 2 Cap screw, gold plated G G Transfer line socket G G Inert ion source body G G Drawout cylinder G G Drawout plate, 3 mm G Drawout plate, 6 mm G G Filament assembly, high temperature (El) G G Lens insulator G G Entrance lens assembly G G Ion focus lens Repeller insulator G G Repeller G G /5975/5973 MSD Electron Impact Ion Source Parts G G AGILENT 5977/7000C EXTRACTOR ION SOURCE PARTS ITEM DESCRIPTION PART NO 3 Extraction source body G Extractor lens G Extractor lens insulator G Filaments, 4-turn G Lens insulator G /7000C Extractor Ion Source Parts Entrance lens assembly G Ion focus lens Repeller insulator G Inert repeller G * 7* 2* 7* 2* * 7* 6* 1* 5975/5973 MSD CHEMICAL IONIZATION ION SOURCE PARTS (CI) ITEM DESCRIPTION PART NO 2 Cap screw, gold plated G Drawout plate G CI 350 repeller assembly G Entrance lens G Filament assembly (CI), 2/pk G /5973 MSD Chemical Ionization Ion Source Parts (CI) Chrom Tech your chromatography specialists

16 Agilent Parts & Supplies GC ACCESSORIES Agilent Mass Spectrometer Supplies (cont.) MSD Filaments AGILENT MSD FILAMENTS DESCRIPTION 7000 SERIES 5977 SERIES 5975 SERIES 5973 SERIES Filament assembly, high temperature (EI), ea G G G G Filament assembly (CI), 2/pk G G G G G G MSD Electron Multipliers and Replacement Horn AGILENT MSD ELECTRON MULTIPLIERS AND REPLACEMENT HORN DESCRIPTION 7000A SERIES 7000B/C SERIES 5973 SERIES 5975 SERIES 5977 SERIES Electron multiplier replacement horn Use with electron multipliers with "straight" horns Triple Axis Detector Assy, 5975 Ceramic G G G Triple axis electron multiplier G G G G High energy dynode G *Included on 5975 triple axis detector systems G Cleaning & Maintenance Supplies AGILENT CLEANING & MAINTENANCE SUPPLIES DESCRIPTION One Year Maintenance Kit (for diffusion pump systems). Includes Big Universal Trap for He (1/8"), abrasive sheets (5/pk), lint-free cloths (15/pk), cotton swabs (100/pk), SantoVac Ultra, 18.5 ml (2 ea), rough pump oil (1 L), filament assembly, octafluoronapthalene (OFN) PART NO Nylon gloves, lint-free, large, 1 pair Nylon gloves, lint-free, small, 1 pair Lint-free industrial wipes, 100% cotton, 9" x 9", 300/pk Ion source cleaning kit. Includes lint-free cloths (15/pk), abrasive sheets (5/pk), cotton swabs (100/pk), lint-free nylon gloves, abrasive Alumina powder Cloths, lint-free, 15/pk Cotton swabs, 100/pk Abrasive sheets, aluminum oxide green lapping paper, 600 mesh, 5/pk Alumina powder, abrasive, 1 kg PFTBA sample, certified, 10 g, 5.32 ml Replacement glass bulb for PFTBA and PFDTD test sample G Replacement glass vial for PFTBA and PFDTD test sample Activated alumina, absorbent pellets for Edwards rough pump traps, non-lc/ms, 1 lb can Quiet Cover DS for vacuum pump models: Agilent DS202, DS302, DS402, DS602 Quiet Cover GC/MS for vacuum pump Models: Pfeiffer Duo2.5, Agilent DS42, Agilent DS42i, Edwards E2M , Pfeiffer Duo 2.5 G or Higher G6012A G6014B G6012A Quiet Cover for vacuum pumps Removable oil tray Easy access to pump Authorized Distributor

17 GC ACCESSORIES Agilent GC Autosampler Syringes Agilent 7693A Autosampler Syringes Blue Line Autosampler Syringes with Fitted plunger syringes are recommended for homogeneous liquid samples. Each fitted syringe is individually matched with the plunger for precision injection. Plungers are not interchangeable or replaceable. Blue Line Autosampler Syringes with PTFE-Tipped Plungers are suitable for gas and liquid samples, the PTFE tip of the plunger creates a tight seal between the plunger and glass, helping to reduce carry-over and increase syringe lifetime. Replacement plungers are available. AGILENT 7693A AUTOSAMPLER SYRINGES VOLUME 1 µ L 2 µ L DESCRIPTION GAUGE 42 mm/cone tip 42 mm/cone tip Fixed Needle Blue Line w/fitted plunger 23 G G Replacement plunger G G AGILENT 7693A AUTOSAMPLER SYRINGES 26 26s "s" indicates thicker wall for added strength VOLUME 5 µ L 10 µ L 25 µ L 50 µ L 100 µ L DESCRIPTION GAUGE 42 mm/hp tip 42 mm/hp tip 42 mm/hp tip 42 mm/hp tip 42 mm/hp tip 23 G G G (6/pk) G (6/pk) Fixed Needle Syringes Removable Needle Syringes & Repl Needles Blue Line w/fitted plunger Blue Line w/ptfe-tipped plunger 26s G G G (6/pk) G (6/pk) 23 26s G G G (6/pk) G (6/pk) G G G G G (6/pk) 23 26s G G (6/pk) G G G G G Repl PTFE Tip plunger for FN G Blue Line w/fitted plunger 23 G G Blue Line w/ptfe-tipped plunger Replacement RN Needles (3/pk) s 23 26s G G G G G G G Advanced Sample Enhancement 7693A Autosampler Syringes with PTFE-Tipped Plungers Used with the 7693A optional Enhanced Sample Handling Syringe Carriage, these syringes can eliminate analyst-to-analyst variability and reduce re-work in sample preparation, such as dilution and internal standard addition. AGILENT SAMPLE ENHANCEMENT 7693A AUTOSAMPLER SYRINGES WITH PTFE-TIPPED PLUNGERS VOLUME 250 µ L 500 µ L DESCRIPTION GAUGE 42 mm/hp tip 42 mm/hp tip Fixed Needle Blue Line w/ptfe-tipped plunger 23 G G Chrom Tech your chromatography specialists

18 Agilent GC Autosampler Syringes GC ACCESSORIES Agilent Gold Standard 7693A Autosampler Syringes Use one needle and get the benefits of two. The upper portion of the tapered needle offers the strength of a 23-gauge needle, while the lower portion at 26s-gauge allows use with split/splitless or on-column injections with 0.53 mm ID columns. All standard plungers are stainless steel. AGILENT GOLD STANDARD 7693A AUTOSAMPLER SYRINGES VOLUME 1 µ L 2 µ L DESCRIPTION GAUGE 42 mm/hp tip 42 mm/hp tip Fixed Needle Blue Line w/fitted plunger AGILENT GOLD STANDARD 7693A AUTOSAMPLER SYRINGES 26 26s Fixed Needle Syringes Removable Needle Syringes & Repl Needles "s" indicates thicker wall for added strength VOLUME 5 µ L 10 µ L 25 µ L 50 µ L 100 µ L DESCRIPTION GAUGE 42 mm/hp tip 42 mm/hp tip 42 mm/hp tip 42 mm/hp tip 42 mm/hp tip Blue Line w/fitted plunger (6/pk) 26s (6/pk) 23 26s (6/pk) (6/pk) (6/pk) (6/pk) Replacement plunger for FN Blue Line w/ptfe-tipped plunger (6/pk) 23 26s (6/pk) Repl PTFE Tip plunger for FN Blue Line w/fitted plunger Blue Line w/ptfe-tipped plunger s s Repl PTFE Tip plunger for RN Replacement RN Needles (3/pk) s HP 7670/71/72 Autosampler Syringes 7673/7683 On-Column Autosampler Syringes HP 7670/71/72 AUTOSAMPLER SYRINGES VOLUME 5 µ L 10 µ L DESCRIPTION GAUGE 56 mm/pt 2 50 mm/hp tip Straight, removable Straight, fixed Straight, fixed, PTFE-tipped plunger /7683 ON-COLUMN AUTOSAMPLER SYRINGES VOLUME DESCRIPTION Removable needle, syringe only SS needle for 0.53 mm column SS needle for 0.32 mm column SS needle for 0.25 mm column Plunger button 5 µ L (3/pk) (3/pk) (3/pk) (10/pk) Authorized Distributor

19 GC ACCESSORIES Agilent Intuvo Agilent Intuvo Guard Chips The Intuvo Guard Chip is an innovative solution that replaces guard columns and extends column lifetime. The Guard Chip is a simple disposable chip that is easily installed and replaced in minutes. These chips prevent unwanted material from depositing on, and damaging the head of the column by providing almost a meter of sample flow path just before the Intuvo GC column, This protection eliminates the need for retention time adjustment and means that you never have to trim a column again. For applications where a Guard Chip is not needed, the jumper chip provides a short direct flow path. The guard and jumper chips are inlet-dependent so versions are available for split/splitless inlets and the multimode inlet. AGILENT INTUVO GUARD CHIPS PART NO DESCRIPTION QTY G Guard Chip, Intuvo, split/splitless inlet 2/pk G Jumper Chip, Intuvo, split/splitless inlet ea G Guard Chip, Intuvo, multimode inlet 2/pk G Jumper Chip, Intuvo, multimode inlet ea G G G G Agilent Intuvo Flow Chips Intuvo Flow Chips are modular components that enable flexible configuration of the GC flow path. These chips provide connections between the inlet, column, and detector without the need for cumbersome ferrules. Furthermore, Intuvo Flow Chips are fitted with smart keys, so Intuvo knows exactly how to set itself up, whether for splitting, backflush, GC detectors, or mass spectrometry. The inlet chip provides a direct connection from the Guard Chip to the column. The D1, D2 and D2-MS chips provide a connection from the column to detector 1, detector 2, or the mass spectrometer. The remaining Flow Chips combine all the complex connections for backflush and splitting into a single device. Some of the Flow Chips require an Intuvo with an additional EPC module configured. AGILENT FLOW CHIPS PART NO DESCRIPTION PURPOSE G Inlet Connects Guard Chip to column G Inlet splitter chip Splits flow from Guard Chip to two columns G D1 Connects column to detector 1 G D2 Connects column to detector 2 G D2-MS Connects column to MS G Mid column backflush to D1 Connects column to detector 1, mid column backflush capability G Mid column backflush to D2 Connects column to detector 2, mid column backflush capability G D1 post column backflush Connects column to detector 1, post column backflush capability G D2-MS post column backflush Connects column to MS detector, post column backflush capability G D1-D2 splitter chip, 1:1 Equally splits column effluent between two GC detectors G D1-MS splitter chip, 1:1 Equally splits column effluent between GC detector and MS G D1-MS splitter chip, 7:1 Splits column effluent between GC detector and MS at 7:1 ratio G G G G G G G G G G G G Chrom Tech your chromatography specialists

20 Agilent Intuvo GC ACCESSORIES Agilent Intuvo Detector Tails AGILENT DETECTOR TAILS PART NO DESCRIPTION G Flow Chip, Intuvo, swaged MS tail G Flow Chip, Intuvo, swaged HES MS tail G Flow Chip, Intuvo, FID-TCD tail G Flow Chip, Intuvo, ECD tail G Flow Chip, Intuvo, NPD tail G Flow Chip, Intuvo, FPD tail G Flow Chip, Intuvo, XCD tail G G G G G G G Agilent Intuvo Gaskets Intuvo uses ferrule-free face seals for all fittings within the sample gas flow path. Gaskets take the place of ferrules throughout the GC, providing the face seal between components of the Intuvo flow path. Easily replaced, these unique leakfree connections enable confident click-and-run column changes. The Intuvo gaskets are available in three types: polyimide, nickel, and as a plug. The polyimide gasket is for standard use up to 350 C, while the nickel gasket provides a solution for high temperature applications up to 450 C. The plug gasket can be used to check for leaks and for troubleshooting the flow path AGILENT INTUVO GASKETS PART NO DESCRIPTION QTY Gasket, Intuvo, polyimide 5/pk Gasket, Intuvo, nickel 2/pk Gasket plug, Intuvo, polyimide 2/pk Intuvo gaskets are intended for one-time use Agilent Intuvo Supplies AGILENT INTUVO SUPPLIES PART NO DESCRIPTION UNIQUE DETECTOR PARTS G FID Jet 0.11" ID COMPRESSION BOLTS G Compression bolt, detector tail G Compression bolt, Intuvo G Compression bolt, Guard Chip G Compression bolt, split/splitless inlet G Compression bolt, multimode inlet TOOLS Wrench, open end, " Wrench, open end, 0.25" Torque driver kit, includes G and G Torque driver extension* Screw driver, torque, preset adjustable* EXHAUST VENT G Exhaust Vent *Includes in G G G G Authorized Distributor

21 GC ACCESSORIESSGE Instrument Quick Pick for Agilent SGE Autosampler Syringes for Agilent 7673, 7683 & 6850 ALS All needles are 42 mm long with a cone point. VOLUME FIXED TAPERED NEEDLE NEEDLE GAUGE (OD mm) SYRINGE CODE SYRINGE QTY SPARE NEEDLE QTY SPARE PLUNGER QTY 5 µl 23 26s (0.63/0.47) 5F-AG-0.63/0.47C ea 10 µl 23 26s (0.63/0.47) 10F-AG-0.63/0.47C ea 10 µl Gas Tight 23 26s (0.63/0.47) 10F-AG-GT-0.63/0.47C ea /pk FIXED STRAIGHT NEEDLE 5 µl 26 (0.47) 5F-AG-0.47C ea 5 µl(m) 23 (0.63) 5F-AG-0.63C ea 10 µl 26 (0.47) 10F-AG-0.47C ea 10 µl(m) 23 (0.63) 10F-AG-0.63C ea 10 µl(m) Gas Tight 23 (0.63) 10F-AG-GT-0.63C ea /pk REMOVABLE TAPERED NEEDLE 0.5 µl 23 26s (0.63/0.47) 0.5BR-AG-0.63/0.47C ea ea** 10 µl 23 26s (0.63/0.47) 10R-AG-0.63/0.47C ea /pk 10 µl Gas Tight 23 26s (0.63/0.47) 10R-AG-GT-0.63/0.47C ea /pk /pk REMOVABLE STRAIGHT NEEDLE 0.5 µl 26 (0.47) 0.5BR-AG-0.47C ea ea** 0.5 µl(m) 23 (0.63) 0.5BR-AG-0.63C ea ea** 1 µl 23 (0.63) 1BR-AG-0.63C ea ea** 10 µl 26 ( R-AG-0.47C ea /pk 10 µl(m) 23 (0.63) 10R-AG-0.63C ea /pk (M) Suitable for use with the Merlin Microseal Injector ** Denotes Spare Needle and Plunger kit SGE Septa for Agilent Instruments PART NO DIAMETER SEPTUM TYPE QTY FOR AGILENT 7890, 6890, 5890, 5880, 4890 & CS 50/pk TCS Pre-drilled 50/pk Auto-Sep T 100/pk HT 25/pk EC 25/pk 382 Chrom Tech your chromatography specialists

22 SGE Instrument Quick Pick for Agilent GC ACCESSORIES SGE Inlet Liners for Agilent Instruments DESCRIPTION AND GEOMETRY SKETCH OD (mm) ID (mm) LENGTH (mm) QTY PART NO FOR AGILENT 5890, 6850, 6890, 7890 & HP4890 Split / Splitless FocusLiner ea /pk /pk Split/ Splitless Tapered FocusLiner ea /pk /pk Split / Splitless FAST FocusLiner ea /pk /pk Split/Splitless Tapered FAST FocusLiner ea /pk /pk Split, Straight-through Liner ea /pk /pk Split, with Quartz Wool ea /pk /pk Split / Splitless with Single Taper ea /pk /pk Split / Splitless with Single Taper (Quartz Wool) ea /pk /pk Split / Splitless with Double Taper ea /pk /pk Direct, Straight-through Liner 5/pk /pk Split / Splitless Quartz, Straight-through Liner ea /pk Taper/Gooseneck FocusLiner Taper Focus ConnecTite Straight Double Taper PTV/LVI Splitless with Recessed Gooseneck ea /pk Split / Splitless Recessed Gooseneck (Quartz Wool) ea /pk /pk PACKED COLUMN LINER FOR AGILENT 5880, 5890, & mm ID Packed Column Liner ea /pk /pk FOR AC CONTROL INJECTOR Sim Dist Liner for Programmed Injector 5/pk /pk FOR GERSTEL CIS 4 INJECTOR Sintered Glass, Large Volume Injection (LVI) ea /pk Single Baffle /pk Authorized Distributor

23 GC ACCESSORIESSGE Instrument Quick Pick for Agilent SGE O-Rings for Agilent Instruments PART NO DESCRIPTION USAGE QTY Viton O-Ring Can be used at temperatures up to 300 C. Suitable for liners with OD of 6.3 mm Graphite Sealing Ring Can be used at temperatures up to 450 C. Suitable for all inlet liners above except and Graphite Sealing Ring Can be used at temperatures up to 450 C. Suitable for use with liners and /pk 10/pk 10/pk SGE Ferrules for Agilent Instruments INSTRUMENT COLUMN ID FERRULE ID QTY PART NO 15% GRAPHITE / 85% VESPEL FERRULES For Injectors & Detectors at atmospheric pressure e.g. FID For GC-MS Interface Connection 100% GRAPHITE FERRULES Injectors & Detectors at atmospheric pressure e.g. FID (Not for GC-MS) S iltite METAL FERRULES For GC-MS Interface Connection (Starter Kit) For Split / Splitless Injectors (Starter Kit) REPLACEMENT SilTite METAL FERRULES For All Connections REPLACEMENT SilTite NUTS mm 0.4 mm 10/pk mm 0.5 mm 10/pk mm 0.8 mm 10/pk for 1/8" OD Packed Columns 1/8" 10/pk for 1/4" OD Packed Columns 1/4" 10/pk mm 0.4 mm 10/pk mm 0.5 mm 10/pk mm 0.8 mm 10/pk mm 0.5 mm 10/pk mm 0.8 mm 10/pk for 1/8" OD Packed Columns 1/8" 10/pk for 1/4" OD Packed Columns 1/4" 10/pk mm 0.4 mm 10/pk * mm 0.5 mm 10/pk * mm 0.8 mm 10/pk * mm 0.4 mm 10/pk ** mm 0.5 mm 10/pk ** mm 0.8 mm 10/pk ** /32* 0.81 mm 10/pk ** mm 0.4 mm 10/pk mm 0.5 mm 10/pk mm 0.8 mm 10/pk /32" 0.81 mm 10/pk For GC-MA Interface Connections 5/pk For Split / Splitless Injector 5/pk REPLACEMENT SilTite BASE SEALS For Split / Splitless Injector * Includes: 10 ferrules, 2 SilTite nuts ** Includes: 10 ferrules, 2 SilTite nuts and 2 SilTite Inlet Base Seals 2/pk /pk Chrom Tech your chromatography specialists

24 SGE Instrument Quick Pick for Agilent GC ACCESSORIES SGE SilTite FingerTite Ferrules for Agilent Instruments PART NO DESCRIPTION QTY Siltite Fingertite Agilent INJ / FID Starter Kit * Siltite Fingertite Agilent INJ / MS Starter Kit * Siltite Fingertite Ferrule 0.4 mm Replacement Items 10/pk Siltite Fingertite Ferrule 0.5 mm Replacement Items 10/pk Siltite Fingertite Blanking Ferrule Replacement Items 2/pk Siltite Fingertite Female Nut Replacement Items 5/pk Siltite Fingertite Agilent INJ Base Seal Replacement Items 2/pk * Each starter kit includes all the parts necessary to convert one GC system (one injector and one detector) to the SilTite FingerTite system suitable for installing mm ID capillary columns. In addition there are 5 SilTite FingerTite nuts, one packet (10 ferrules) of 0.4 mm ID SilTite Fingertite ferrules and a ferrule install tool which allows you to seat the ferrule in the correct position on the capillary column SGE Electron Multipliers for Agilent Instruments PART NO INSTRUMENT ANALYZER TYPE TECHNIQUE (All) Quadrupole GC-MS , 5972, GCD Quadrupole GC-MS (For initial installation includes mount) Quadrupole GC-MS (Replacement multiplier only) Quadrupole GC-MS Authorized Distributor

25 GC ACCESSORIESSGE Instrument Quick Pick for Shimadzu SGE Autosampler Syringes for Shimadzu AOC14, AOC17 and AOC20 All needles are 42 mm long with a cone point style. VOLUME NEEDLE GAUGE (OD mm) SYRINGE CODE SYRINGE QTY SPARE NEEDLE QTY SPARE PLUNGER QTY FIXED NEEDLE 5 µl 23 (0.63) 5F-S-0.63C ea REMOVABLE NEEDLE 0.5 µl 26 (0.47) 0.5BR-PE-0.47C ea ea* 0.5 µl 23 (0.63) 0.5BR-PE-0.63C ea ea* 0.5 µl 23 26s (0.63/0.47) 0.5BNR-S-0.63/0.47C ea* 10 µl 26 (0.47) 10R-S-0.47C ea /pk 10 µl 23 (0.63) 10R-S-0.63C ea /pk 10 µl Gas Tight 23 (0.63) 10R-S-GT-0.63C ea /pk /pk *Denotes spare Needle and Plunger kit SGE Septa for Shimadzu Instruments PART NO SEPTUM TYPE QTY FOR SHIMADZU 9A, 14, 15A, 16, 17A, 2010 & Enduro Blue 50/pk HT 50/pk 386 Chrom Tech your chromatography specialists

26 SGE Instrument Quick Pick for Shimadzu GC ACCESSORIES SGE Inlet Liners for Shimadzu Instruments DESCRIPTION AND GEOMETRY SKETCH OD (mm) ID (mm) LENGTH (mm) QTY PART NO FOR GC-2010 (SPL-2010 INJECTOR), GC-2014 (SPL-2014 INJECTOR) AND GC-17A (SPL-17 INJECTOR) Split/ Splitless FocusLiner * ea /pk /pk Split / Splitless Tapered FocusLiner ea /pk /pk Split/ Splitless FocusLiner ea /pk Split/ Splitless Tapered FocusLiner ea /pk /pk Split, Straight-through Liner ea /pk Splitless, Straight-through Liner ea /pk Split / Splitless with Single Taper ea /pk Split / Splitless with middle gooseneck ea /pk Split / Splitless with recessed gooseneck & quartz wool ea /pk Taper/Gooseneck FocusLiner Taper Focus ConnecTite Straight Double Taper PTV/LVI Split / Splitless with middle gooseneck ea /pk /pk ConnecTite (0.53 mm ID columns) ea /pk SPME Liner ea /pk FOR GC-14 (SPL-14 INJECTOR) Split / Splitless FocusLiner ea /pk Split / Splitless Tapered FocusLiner ea /pk Split / Splitless with 2.0 mm middle gooseneck ea /pk Split / Splitless with Single Taper ea /pk Splitless, Direct, wide bore liner for Shimadzu 9A/16A GC ea /pk * When using a standard 42 mm needle for autosamplers, the sample will be injected on top of the wool for this liner. Authorized Distributor

27 GC ACCESSORIESSGE Instrument Quick Pick for Shimadzu SGE O-Rings and Sealing Rings for Shimadzu Instruments PART NO DESCRIPTION USAGE QTY Graphite Sealing Ring Can be used at temperatures up to 450 C. For 14, 15A & 16 (SPL-14 injector) Graphite Sealing Ring Can be used at temperatures up to 450 C For 17A (SPL-17 injector) Viton O-Ring Can be used at temperatures up to 300 C For 2010 & 2014 (SPL-2010 injector & SPL-2014 injector) 10/pk 10/pk 10/pk SGE Ferrules for Shimadzu Instruments PART NO COLUMN ID DESCRIPTION QTY FOR GC14A, GC17A, GC2010 AND GC2014 DETECTOR / INJECTORS (NOT FOR MS INTERFACES OR QP2010 INJECTOR) mm ID columns 100% Graphite 10/pk mm ID columns 100 % Graphite 10/pk mm OD packed columns 100% Graphite 10/pk mm ID columns SilTite Metal Initial installation 10/pk* mm ID columns SilTite Ferrules 10/pk mm ID columns SilTite Metal Initial Installation 10/pk* mm ID columns SilTite Ferrules 10/pk mm ID columns SilTite Metal Initial Installation 10/pk* mm ID columns SilTite Ferrules 10/pk n/a SilTite Metal Nuts Slotted 5/pk FOR QP5000/5050 STANDARD MS INTERFACE QP5000-I mm ID columns 15% Graphite / 85% Vespel Ferrules 10/pk QP5000-I 0.32 mm ID columns 15% Graphite / 85% Vespel Ferrules 10/pk QP5000-II & QP mm ID columns 15% Graphite / 85% Vespel Ferrules 10/pk QP5000-II & QP mm ID columns 15% Graphite / 85% Vespel Ferrules 10/pk mm ID columns SilTite Metal Initial Installation 10/pk* mm ID columns SilTite Ferrules 10/pk mm ID columns SilTite Metal Initial Installation 10/pk* mm ID columns SilTite Ferrules 10/pk mm ID columns SilTite Ferrules 10/pk n/a SilTite Metal Nuts 5/pk FOR QP5000/5050 WIDE BORE MS INTERFACE, QP2010 INJECTOR AND QP2010 STANDARD MS INTERFACE mm ID column 15% Graphite / 85% Vespel Ferrules 10/pk mm ID columns 15% Graphite / 85% Vespel Ferrules 10/pk mm ID columns 15% Graphite / 85% Vespel Ferrules 10/pk mm ID columns SilTite Metal Initial Installation 10/pk* mm ID columns SilTite Ferrules 10/pk mm ID columns SilTite Metal Initial Installation 10/pk* mm ID columns SilTite Ferrules 10/pk mm ID columns SilTite Metal Initial Installation 10/pk* mm ID columns SilTite Ferrules 10/pk n/a SilTite Metal Nuts 5/pk * Includes 10 ferrules, 2 SilTite nuts Chrom Tech your chromatography specialists

28 SGE Instrument Quick Pick for Shimadzu GC ACCESSORIES SGE Replacement SilTite Nuts for Shimadzu Instruments PART NO MATERIAL QTY For 2010 GC-MS System 5/pk For 2010 GC-MS System with QP5000 series MS 5/pk For 2010 / 2014 GC Injectors and atmospheric detectors 5/pk QP5000 Jet Separator MS Interface 5/pk QP5000 Direct MS Interface 5/pk For All Injectors Jet Separator (Starter Kit) except 2010/2014 5/pk SGE SilTite FingerTite Ferrules for Shimadzu Instruments PART NO DESCRIPTION QTY SilTite Fingertite Shimadzu 2010 Inj / Fid Starter Kit * SilTite Fingertite 5/pk SilTite Fingertite Ferrule 0.4 mm Replacement Items 10/pk SilTite Fingertite Ferrule 0.5 mm Replacement Items 10/pk SilTite Fingertite Blanking Ferrule Replacement Items 2/pk SilTite Fingertite Female Nut Replacement Items 5/pk * Each starter kit includes all the parts necessary to convert one GC system (one injector and one detector) to the SilTite FingerTite system suitable for installing mm ID capillary columns. In addition there are 5 SilTite FingerTite nuts, one packet (10 ferrules) of 0.4 mm ID SilTite Fingertite ferrules and a ferrule install tool which allows you to seat the ferrule in the correct position on the capillary column. SGE Electron Multipliers for Shimadzu Instruments PART NO MS DESCRIPTION ANALYZER TYPE TECHNIQUE QP5000 Quadrupole GC-MS Authorized Distributor

29 GC ACCESSORIESSGE Instrument Quick Pick for Thermo Scientific SGE Autosampler Syringes for Thermo Scientific / CE Instruments / Fisons All needles have a cone point style. AUTOSAMPLER NEEDLE SPECIFICATIONS TriPlus AS3000 AS2000 AS200/800 VOLUME (µ L) LENGTH (mm) GAUGE SYRINGE CODE SYRINGE NEEDLE QTY FIXED NEEDLE (0.63) 10F-C/T-GT-5/0.63C (0.47) 10F-C/T-8/0.47C (0.63) 10F-C/T-5/0.63C (0.47) 10F-C/T-5/0.47C REMOVABLE NEEDLE (0.47) 10R-C/T-5/0.47C (0.63) 10R-C/T-5/0.63C /pk (0.47) 10R-C/T-8/0.47C /pk (0.47) 0.5bnr-C/T-5/0.47C (0.63) 0.2BNRC/T-5/0.63C SGE Septa for Thermo 8000 Series, FOCUS, Trace/Ultra GC PART NO DIAMETER SEPTUM TYPE QTY HT 25/pk EE 25/pk SGE Inlet Liners for Thermo TRACE & Focus DESCRIPTION AND GEOMETRY SKETCH OD (mm) ID (mm) LENGTH (mm) QTY PART NO Splitless FocusLiner (for use with 70 mm needle) Splitless FocusLiner with Top-end Restriction (for use with 70 mm needle) Split FocusLiner (for use with 50 mm needle) Splitless FocusLiner (for use with 50 mm needle) ea /pk ea /pk /pk /pk ea /pk Taper/Gooseneck FocusLiner Taper Focus ConnecTite Straight Double Taper PTV/LVI Splitless with Single Taper Splitless with Single Taper Splitless, Straight-through Liner SPME Liner ea /pk /pk ea /pk /pk ea /pk ea /pk Split, Straight-through Liner Trace 2000 PTV Liner /pk /pk Sintered Glass, Large Volume Injection (LVI) Liner Chrom Tech your chromatography specialists / ea /pk /pk

30 SGE Instrument Quick Pick for Thermo Scientific GC ACCESSORIES SGE Sealing Rings for Thermo Instruments PART NO DESCRIPTION USAGE QTY Graphite Sealing Ring 8 mm ID. For 8000 & TRACE GCs. 10/pk SGE Ferrules for Thermo Instruments INSTRUMENT COLUMN ID FERRULE ID QTY PART NO 15% GRAPHITE / 85% VESPEL FERRULES For All Injectors & Detectors (Not for 8000 Series, Focus, Trace/Ultra GC) For All Focus, Trace/Ultra Injectors & Detectors at atmospheric pressure e.g. FID (Not for GC-MS) Brass Nut for Focus, Trace/Ultra GC Injectors & Non-MS Detectors 100% GRAPHITE FERRULES For Injectors & Detectors at atmospheric pressure e.g. FID (Not for GC-MS) S iltite METAL FERRULES For GC-MS Interface Connection (Starter Kit) REPLACEMENT SilTite METAL FERRULES For GC-MS Interface Connection mm 0.4 mm 10/pk mm 0.5 mm 10/pk mm 0.8 mm 10/pk mm 0.4 mm 10/pk# mm 0.5 mm 10/pk# mm 0.8 mm 10/pk# /pk mm 0.5 mm 10/pk mm 0.5 mm 10/pk for 1/8" OD Packed Columns 1/8" 10/pk for 1/4" OD Packed Columns 1/4" 10/pk mm 0.4 mm 10/pk* mm 0.5 mm 10/pk* mm 0.8 mm 10/pk* mm 0.4 mm 10/pk mm 0.5 mm 10/pk mm 0.8 mm 10/pk /32" 0.81 mm 10/pk Replacement SilTite Nuts 5/pk # To be used in combination with brass nut (Part No ) * Includes: 10 ferrules, 2 SilTite nuts SGE SilTite FingerTite Ferrules for Thermo Instruments PART NO DESCRIPTION COLUMN ID FERRULE ID (mm) QTY Injector/GC MS (non ISQ) mm 0.4 * Injector/GC MS ISQ mm 0.4 * Injector/FID mm 0.4 * Ferrule 0.4 mm mm /pk Ferrule 0.5 mm 0.32 mm /pk Ferrule Blanking 2/pk Female Nut 5/pk * Each starter kit includes all the parts necessary to convert one GC system (one injector and one detector) to the SilTite FingerTite system suitable for installing mm ID capillary columns. In addition there are 5 SilTite FingerTite nuts, one packet (10 ferrules) of 0.4 mm ID SilTite Fingertite ferrules and a ferrule install tool which allows you to seat the ferrule in the correct position on the capillary column. Authorized Distributor

31 GC ACCESSORIES Gas Management Agilent Flow Meters Precision Gas Flow Meter High accurate and reliable measurement of common carrier and fuel gases used in GC, including nitrogen, air, carbon dioxide, hydrogen, helium, and argon methane Two year guaranteed calibration period traceable to NIST standards Measures flow based on gas viscosity properties with an accuracy of ±0.8% of reading + 0.2% of full scale volume Flow rate range from ml/min Displays mass flow, volumetric flow, temperature and pressure readings simultaneously Can be plumbed inline Agilent s Precision Gas Flow Meter is the ultimate gas flow meter for chromatography applications. This hand-held flow meter incorporates industry leading performance and features a highly accurate and reliable package. The inherent stability of the rugged, solid state components allows us to provide the longest calibration interval on the market, all traceable to NIST standards. ADM Flowmeter Accuracy ± 2% of reading or ± 0.2 ml/min Operating temp range 0 45 C for the instrument, C for the tubing Calibration NIST traceable cartridge (G6692A) Flow rate range from ml/min Allows for continuous real time flow measurement with data storage The Agilent ADM Flow Meter is a reliable platform for measuring volumetric gas flow without having to know the gas composition (limited to non-caustic gases). Moreover, the Agilent ADM Flow Meter does not have to be shipped back for recalibration to maintain NIST-Traceable standards. Simply order a new NIST-calibrated cartridge and replace the old cartridge yourself. Guaranteed accuracy A built-in calibration timer automatically warns you when the calibration cartridge needs replacing. This minimizes the risk of volumetric measurement drift. Hands-free operation/easy view of screen The kickstand feature allows you to conveniently operate above bench level. Direct download of new features/capabilities There s no need to ship the flow meter out every time a firmware upgrade is needed. AGILENT FLOW METERS PART NO DESCRIPTION Precision Gas Flow Meter G6691A ADM Flow Meter ADM FLOW METER ACCESSORIES G6692A FID Adapter NPD Adapter TCD Adapter FLOW RATE (ml/min) ACCURACY ± 0.8 % of reading + 0.2% of full scale ± 2 % of reading or 0.2 ml/min, whichever is greater Replaceable NIST calibrated cartridge ECD Detector Split Vent Adapter FLOW THROUGH DESIGN GASES MEASURED (NON-CORROSIVE) VOLUMETRIC 1 OR MASS 2 FLOW METER COMMUNICATION UNIQUE FEATURES Both RS232 output Displays mass flow, Yes N 2, H 2, He, Air, CO 2, CH 4, 95% Ar/CH 4 volumetric flow, temperature and pressure readings simultaneously No All Both USB Replaceable NIST calibrated cartridge POWER SUPPLY 9v battery (3) AA Alkaline batteries & USB 1) Volumetric measurements are accurate and are independent of the gas that is being measured, allowing measurements of mixed gases commonly found in chromatography. 2) Mass flow measurements are very accurate for specific gases and are not affected by temperature and pressure fluctuations 392 Chrom Tech your chromatography specialists

32 Gas Management GC ACCESSORIES Agilent Gas Leak Detector AGILENT GAS LEAK DETECTOR PART NO G3388B Detects thermal conductivity differences Audible and visual alerts Min. detection limit ml/min hydrogen and helium Lightweight only 105 g Small roughly 50 x 19.5 x 111 mm Rechargeable lithium ion battery with over 5 hours of life Includes a USB cable for battery charging One year warranty ACCESSORIES DESCRIPTION Handheld electronic gas leak detector Replacement filter tip Replacement battery G3388B Gas leaks can cause detector noise and baseline instability, shorten column life and waste expensive carrier gas. Liquid leak detectors, although inexpensive, can contaminate your system. Agilent s G3388B electronic leak detector is an easy way to quickly identify leaks in your system and prevent system downtime. Agilent Gas Cylinder Regulators, U.S. Only To plumb your system properly, select one of our economical brass regulators and the proper gas purification devices from our newly expanded product offering. BRASS BODY, DUAL STAINLESS STEEL DIAPHRAGMS SPECIFICATIONS MAX INLET PRESSURE OPERATION TEMP RANGE INLET/OUTLET 3,000 PSI -40 F 165 F 1/4", MNPT OUTLET VALVE DELIVERY PRESSURES WEIGHT 1/4", MNPT, 2 1/2" in dualscale gauges, CGA-346, 350, 340, 580, 590, Internal selfreseating relief valve Body: Brass Bonnet: Brass Seat assemblies: Encapsulated Seat material: PTFE PSI 5.6 lb Gauges: Brass Diaphragms: Stainless steel Outlet needle valve: Brass Adjusting Knob GAS CYLINDER REGULATORS PART NO DESCRIPTION Snoop Leak test most pressurized gas systems. We recommend that leak detecting solutions be used with care where there is any possibility of the fluid being aspirated into gas flow streams supplying the column or detector. This squeezable bottle comes with a "Snooper Tube" extendable up to 12 inches. Electronic leak detectors are preferred. In their absence, a volatile nonreactive solvent like Snoop may be used. Use caution to avoid aspiration of materials such as snoop into the column. SNOOP PART NO DESCRIPTION Snoop, 8 oz (236 ml) bottle Snoop, 1 gallon bottle BRASS BODY, TWO-STAGE STAINLESS STEEL DIAPHRAGMS, 1/8", U.S. ONLY CGA 346, 125 psi max, Air CGA 350, 125 psi max, H2, Ar/Me CGA 540, 125 psi max, O CGA 580, 125 psi max, He, Ar, N CGA 590, 125 psi max, Air CONNECTORS (SWAGELOK TO FEMALE NPT) /8" (1) x 1/4" (B) connector, brass (included with brass regulators) /4" (A) x 1/4" (B) connector, brass 2 ACCESSORIES Copper tubing, 1/8", 50 ft Copper tubing, 1/8", 12 ft PTFE tape, industrial roll Cylinder wall bracket with strap & chain (cylinder size up to 14", 35 cm) Authorized Distributor

33 GC ACCESSORIES Gas Purification Systems DETECTOR CONNECTION DIAGRAMS FID Flame Ionization Detector (Carrier Gas = Make-Up Gas) Carrier Gas Oxygen Filter Moisture Filter Column Hydrogen Air Charcoal Filter Charcoal Filter FID FID Flame Ionization Detector (Carrier Gas differs from Make-Up Gas) Carrier Gas GC/MS Filter Column Make-Up Gas Charcoal Filter Hydrogen Air Charcoal Filter Charcoal Filter FID MS (ITD, MSD) Ion Trap Detector, Mass Selective Detector Two Possibilities (See diagrams to the right) Carrier Gas GC/MS Filter Column MS Carrier Gas Oxygen Filter Moisture Filter Column MS TCD Thermal Conductivity Detector Carrier Gas Oxygen Filter Moisture Filter Column Reference Channel Make-Up Gas, if necessary TCD ICP-OES/ICP-MS Inductively Coupled Plasma-Optical Emission Spectrometry/Mass Spectrometry (Plasma Gas = Nebulizer Gas) Supply Gas Oxygen Filter Oxygen Filter ICP-MS ICP-OES ICP-OES Inductively Coupled Plasma-Optical Emission (Different Optic Flush Gas) Supply Gas Oxygen Filter ICP-OES Oxygen Filter High-Flow Base Plate Optic Flush Gas Oxygen Filter TECH TIP Helpful Hints for Purification Success Determine desired purity level Keep number of fittings in gas line to a minimum Install purifiers in a convenient location close to GC Use purifier log books to determine maintenance and cartridge replacement schedule Use indicating traps closest to the GC so you can determine when to change the traps that are upstream 394 Chrom Tech your chromatography specialists

34 Gas Purification Systems GC ACCESSORIES Agilent Gas Clean Filters Deliver clean gases for accurate analyses Fast, leak-free filter replacement reduces downtime Economical, with immediate payback Highly sensitive filter indicators provide maximum instrument protection The Agilent Gas Clean Filter System delivers clean gases, reducing the risks of column damage, sensitivity loss, and instrument downtime. Inserting a Gas Clean Filter System in the gas line immediately before the instrument inlet greatly reduces the level of impurities, thus improving trace analysis. Contaminants entering your GC column will also be reduced, which is critical for high temperature analysis and essential for longer column lifetime. Replacing the filters when they have reached absorption capacity ensures maximum protection of your GC columns and analytical hardware. The sensitive indicators change color, alerting you that the filter needs to be replaced. A Gas Clean Filter System allows you to use % (6.0) grade while still yielding high quality analytical results. The expected cost savings are 30%. AGILENT GAS CLEAN FILTERS SPECIFICATIONS PART NO DESCRIPTION FUNCTION CP17970 Oxygen Filter Removes oxygen as well as traces of sulfur and chlorine compounds from carrier gas CP17971 Moisture Filter Removes water, oil, and other foreign material from the carrier gas CP17971P CP17972 Process Moisture Filter Charcoal Filter *at operating flow of 1 10 L/min Removes water, oil, and other foreign material from the carrier gas INDICATOR COLOR CHANGE CAPACITY OUTLET CONCENTRATION* From green to gray 150 ml oxygen < 50 µg/l From green to pale brown From green to pale brown 7.2 g water < 0.1 mg/l 7.2 g water < 0.1 mg/l Removes organic compounds from gas streams No indicator Approximately 7 g, depending on impurities CP17973 GC/MS Filter Single combination filter, removes water, oxygen, and organic compounds Oxygen, from green to gray; Moisture, from green to pale brown 100 ml oxygen, 1 g water, organics depending on impurities < 0.1 mg/l CP17969 CO 2 Filter Removes CO 2 from the gas stream; use with moisture filter From white to violet 9 g CO 2 < 1 mg/l Oxygen < 50 µg/l Moisture < 0.1 mg/l Organics < 0.1 mg/l AGILENT GAS CLEAN FILTER STARTER KITS DESCRIPTION 1/4" 1/8" Agilent Gas Clean FID Filter kit Includes a 4-position connecting unit and (2) Charcoal filters, (1) Oxygen filter, and (1) Moisture filter Agilent GC Installation Kit Includes CP and many useful fittings and accessories Agilent Gas Clean GC/MS Filter kit Includes a 1-position connecting unit and (2) GC/MS filters Agilent Gas Clean GC/MS Filter Installation kit Includes 1 m copper tubing (P/N CP17976), (2) nuts and (2) ferrules Agilent Gas Clean CO2 kit Includes 2-position connecting unit and CO2 and moisture filters Agilent TCD Filter Kit Includes a 2-position connecting unit, (1) Oxygen filter, and (1) Moisture filter CONNECTING UNITS CP7995 CP N CP17977 CP17976 CP17978 CP17982 CP17983 CP position connecting unit (filters sold separately) CP7980 CP position connecting unit (filters sold separately) CP CP position connecting unit (filters sold separately) CP7989 CP High flow connecting unit, 2-position (filters sold separately) CP17984 CP17985 ACCESSORIES AND FITTINGS DESCRIPTION Wall mounting bracket for connecting unit For CP7980 and CP7988 Upper part filter connecting unit Flush head for connecting unit Male connector, 1/4" w/dust filter Male connector, 1/8" w/dust filter Viton O-rings two sets Male connector, stainless steel, 1/4" w/dust filter Male connector, stainless steel, 1/8" w/dust filter Male connector, stainless steel, 3 mm w/dust filter Male connector, stainless steel, 6 mm w/dust filter CP7988 CP PART NO CP7981 CP7978 CP7987 CP7986 CP82117 CP7983 CP7986SS CP82117SS CP82117SS3 CP7986SS6 Authorized Distributor

35 GC ACCESSORIES Agilent In-Line Gas Traps Agilent Big Traps One Big Universal Trap unit will easily purify the contents of thirteen "K" size cylinders of % purity helium Big Universal Traps utilize a layered, multi-adsorbent bed packing of the most effective, highest capacity adsorbent materials available today for the removal of oxygen, moisture, hydrocarbons, carbon dioxide, and carbon monoxide from helium gas streams. The volume of the various adsorbent materials in the Big Universal Trap was developed through rigorous testing and evaluation in order to ensure that breakthrough of the five major contaminant groups occurs as simultaneously as possible as each material achieves complete saturation. Big Universal Traps are ideal for any GC or GC/MS application where helium is employed and assurance of purity is essential. Combining the contents of three individual in-line traps into a single unit reduces the number of potential leaks and the possibility of aspirating contaminants into the gas stream. A single purifier also simplifies installation and replacement. AGILENT BIG TRAPS DESCRIPTION CAPACITY EFFICIENCY 1/8" 1/4" BIG UNIVERSAL TRAPS (RMS SERIES) Hydrogen 1.07 L O2, 20 g THC*, 46 g H2O see effluent chart RMSHY-2 RMSHY-4 Helium (Ar/Me) 1.07 L O2, 20 g THC*, 46 g H2O see effluent chart RMSH-2 RMSH-4 Nitrogen 1.07 L O2, 20 g THC*, 46 g H2O see effluent chart RMSN-2 RMSN-4 BIG TRAPS Big Moisture Trap 130 g H 2 O Reduction of H 2 O to less than 5 µg/l Big Oxygen Trap 3 L O 2 or 3.2 g Reduction of O 2 to less than 1 µg/l Big Hydrocarbon Trap MOUNTING CLIPS Big Mounting Clip, 2/pk 80 g of medium to heavy molecular weight hydrocarbons Reduction of C4 hydrocarbons to less than 15 µg/l REFILL 1500 CC BMT-2 BMT-4 BMSR-1 BOT-2 BOT-4 BHT-2 BHT-4 BACR UMC-5-2 EFFLUENT CONCENTRATION FROM UNIVERSAL BIG TRAP RESEARCH GRADE HELIUM, % Impurities N 2 O 2 THC* CO+CO 2 H 2 O H 2 Ar Ne BMT-2 TECH TIP The effectiveness of the traps depends on the initial quality of the gas < 1 mg/l < 0.5 mg/l < 0.5 mg/l < 0.1 mg/l < 0.1 mg/l < 0.2 mg/l < 0.2 mg/l < 0.1 mg/l < 0.5 mg/l *Total Hydrocarbons, analysis limited to three contaminant groups Agilent Standard Size Gas Traps AGILENT STANDARD SIZE IN-LINE GAS TRAPS DESCRIPTION CAPACITY EFFICIENCY INDICATING TRAPS SIZE (cc) 1/8" 1/4" Glass Indicating Moisture Trap Glass Indicating Oxygen Trap Glass Indicating Oxygen Trap, Stainless Steel Fitting NON-INDICATING TRAPS Oxygen Trap < 1 µg/l 70 OT1-2 OT1-4 Hydrocarbon Trap 200 HT200-2 HT200-4 REFILL 1 PINT Capillary Grade Hydrocarbon Trap 100 HT3-2 HT3-4 ACR Oxygen/Moisture Trap 500mL O 2 or 2 g H 2 O <15 µg/l 100 OT3-2 OT3-4 Hydrocarbon/Moisture Trap 200 HMT200-2 HMT200-4 HCRMS Mounting clip for Non-Indicating Traps MC-1 MC-1 UNIVERSAL/EXTERNAL SPLIT VENT TRAP Universal/external split vent trap with 3 cartridges, 1/8" Swagelok fitting RDT-1020 Replacement cartridges, 3/pk RDT-1023 Glass Indicating Oxygen trap Oxygen trap, OT1-2 Hydrocarbon trap, HT200-2 TECH TIP Glass indicating oxygen trap is recommended as a downstream indicator for high-capacity traps 396 Chrom Tech your chromatography specialists

36 Gas Management Fittings & Connections GC ACCESSORIES Restek Swagelok Fittings RESTEK SWAGELOK FITTINGS QTY PART NO QTY PART NO QTY PART NO FITTING TYPE SIZE SWAGELOK # Brass 316 Stainless Steel Siltek/Sulfinert Treated Nut 1/16" /pk RTK /pk RTK /8" /pk RTK /pk RTK /4" /pk RTK /pk RTK Front Ferrule 1/16" /pk RTK /pk RTK /8" /pk RTK /pk RTK /4" /pk RTK /pk RTK Back Ferrule 1/16" /pk RTK /pk RTK /8" /pk RTK /pk RTK /4" /pk RTK /pk RTK Nut & Ferrule Set 1/16" 10/pk RTK /pk RTK /8" 20/pk RTK /pk RTK /4" 20/pk RTK /pk RTK Plug 1/16" 100-P 5/pk RTK /pk RTK /8" 200-P 10/pk RTK pk. RTK ea RTK /4" 400-P 10/pk RTK pk. RTK ea RTK Union 1/16" /pk RTK ea RTK ea RTK /8" /pk RTK /pk RTK ea RTK /4" /pk RTK /pk RTK ea RTK Reducing Union 1/8" to 1/16" /pk RTK ea RTK ea RTK /4" to 1/16" /pk RTK /pk RTK ea RTK /4" to 1/8" /pk RTK /pk RTK ea RTK Tee 1/16" /pk RTK ea RTK ea RTK /8" /pk RTK ea RTK ea RTK /4" /pk RTK ea RTK ea RTK Male Connector 1/8" to 1/4" NPT /pk RTK /pk RTK ea RTK Nut Front ferrule Back ferrule Nut & ferrule set Plug Tee Union Reducing union Male connector Gas Management Accessories MISCELLANEOUS GAS MANAGEMENT PART NO DESCRIPTION Pre-cleaned copper tubing, 1/8" OD, 2.1 mm ID, 50 ft length Ceramic Wafer GC Column Cutter, 4/pk TT-1008 Terry Tool tubing cutter for 1/8" with 3 replacement wheels Angled wrench for split/splitless septum nut Wrench, 1/2" and 7/16" (for typical 1/8" tube connections) Adjustable wrench, 12", for use with regulators FID Cleaning kit (improves sensitivity, reduces noise and decreases detector spiking) Cylinder wall bracket with strap and chain (cylinder size up to 14") TT

Recent Advances to Ensure Simple, Leak Free GC Column Connections. Ken Lynam R&D/Application Chemist Agilent Consumables and Supplies Division

Recent Advances to Ensure Simple, Leak Free GC Column Connections. Ken Lynam R&D/Application Chemist Agilent Consumables and Supplies Division Recent Advances to Ensure Simple, Leak Free GC Column Connections Ken Lynam R&D/Application Chemist Agilent Consumables and Supplies Division 1 GC column installation is a challenge A routine, basic procedure

More information

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 7820MSD Series G3175A (G7020A), G3176A (G7021A)

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 7820MSD Series G3175A (G7020A), G3176A (G7021A) Purpose of Procedure Your site must meet this specification or set of requirements to assure a successful and timely installation of your 7820MSD Series Mass Selective Detector (MSD). This checklist is

More information

Best Practice for Identifying Leaks in GC and GC/MS Systems

Best Practice for Identifying Leaks in GC and GC/MS Systems Best Practice for Identifying Leaks in GC and GC/MS Systems Technical Overview Maintaining a leak-free GC or GC/MS system is critical for obtaining optimal system performance with reliable, reproducible,

More information

6890 GC Site Preparation

6890 GC Site Preparation 6890 GC Site Preparation (a16011) This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use of this material. The information

More information

Considerations and Best Practices for Maintaining Your Agilent GC s Split/Splitless Injection Port

Considerations and Best Practices for Maintaining Your Agilent GC s Split/Splitless Injection Port Considerations and Best Practices for Maintaining Your Agilent GC s Split/Splitless Injection Port So, Why Do I Have To Do Maintenance? 1. Things wear out septa, syringes, nuts, ferrules, o-rings, etc.

More information

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 5975C MSD Series G3170A, G3171A, G3172A, G3174A

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 5975C MSD Series G3170A, G3171A, G3172A, G3174A Purpose of Procedure Your site must meet this specification or set of requirements to assure a successful and timely installation of your 5975C Series Mass Selective Detector (MSD). This checklist is designed

More information

Customer Responsibilities. Important Customer Information GCMS QQQ Site Preparation Checklist

Customer Responsibilities. Important Customer Information GCMS QQQ Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

no peaks missing peaks too small peaks increasing retention decreasing retention

no peaks missing peaks too small peaks increasing retention decreasing retention GC Troubleshooting We can help you. 1. Observation: no peaks no peaks missing peaks too small peaks increasing retention decreasing retention declining baseline rising baseline bleeding plateaus interfering

More information

Please refer to the Hydrogen Safety Guide which is shipped with the Instrument. 5977B Series GC/MS Systems Site Preparation Checklist

Please refer to the Hydrogen Safety Guide which is shipped with the Instrument. 5977B Series GC/MS Systems Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

Products Designed to Solve Nagging GC Problems

Products Designed to Solve Nagging GC Problems Products Designed to Solve Nagging GC Problems Abby Folk Chromatography Technical Specialist Page 1 Contaminated Gas Fouls the Whole GC Dirty Lines, Inlet, Column, Detector More Frequent Maintenance More

More information

Super-Clean Gas Filters from Restek

Super-Clean Gas Filters from Restek Super-Clean Gas Filters from Restek Chromatography Products www.restek.com 800-356-688 84-353-300 regulator instrument-grade tubing on/off valve GC carrier gas moisture trap hydrocarbon trap high-capacity

More information

Agilent G3180B Two-Way Splitter Kit

Agilent G3180B Two-Way Splitter Kit Agilent G3180B Two-Way Splitter Kit With Makeup Gas Installation and Operation Guide Agilent Technologies Notices Agilent Technologies, Inc. 2006 No part of this manual may be reproduced in any form or

More information

7820A GC Site Preparation Checklist

7820A GC Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

For additional information about our solutions, please visit our web site at US/Pages/HomePage.

For additional information about our solutions, please visit our web site at  US/Pages/HomePage. Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

Agilent 7890 / 220 Ion Trap GCMS Site Preparation Checklist

Agilent 7890 / 220 Ion Trap GCMS Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane Gas requirements Gases for packed columns The carrier gas you use depends upon the type of detector and the performance requirements. Table 520-1 lists gas recommendations for packed column use. In general,

More information

Mass Spec will not Autotune

Mass Spec will not Autotune Mass Spec will not Autotune Applies to 5973A/N MSD What could be the problem? There could be several things that would cause your Mass Spec not to Autotune. The most common, easily corrected Autotune problems

More information

Capillary Conversion System CCS-4/NC & CCS-05/NC. Installation and Operating Instructions. Operating Instructions

Capillary Conversion System CCS-4/NC & CCS-05/NC. Installation and Operating Instructions. Operating Instructions Operating Instructions Check the detector for the correct operating conditions. If make-up gas is being used a flow of 30ml/min. of carrier plus make-up is normally recommended. This can most effectively

More information

Thermo Scientific Chromatography Well Plates

Thermo Scientific Chromatography Well Plates Thermo Scientific Chromatography Well Plates High-throughput sample handling solutions Well Plates for Chromatography A full selection of high quality sample well plates for your UHPLC, LC and GC applications.

More information

Thermo Scientific Chromatography Well Plates

Thermo Scientific Chromatography Well Plates Thermo Scientific Chromatography Well Plates High-throughput sample handling solutions Well Plates for Chromatography A full selection of high quality sample well plates for your UHPLC, LC and GC applications.

More information

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more! After years of development and testing, DPS Instruments is pleased to present the newest, most expandable and versatile Gas Chromatography Systems in history. The DPS 600 Series GC systems are the world

More information

Instant Connect Helium Saver Injector Module

Instant Connect Helium Saver Injector Module Thermo Scientific Instant Connect Helium Saver Injector Module for TRACE 1300/1310 Gas Chromatographs User Guide PN 31709737 Revision B January 2016 2016 Thermo Fisher Scientific Inc. All rights reserved.

More information

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems Inorganic Analysis Chromatography Molecular Spectroscopy Thermal/Elemental Analysis Informatics Gas Chromatography MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass

More information

Markes Thermal Desorption Systems Site Preparation Page 1 of 8

Markes Thermal Desorption Systems Site Preparation Page 1 of 8 Thermal Desorption Systems Site Preparation Purpose of site preparation Your site must meet this specification to assure a successful and timely installation of your Agilent thermal desorption equipment.

More information

Ghost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager

Ghost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager Ghost Peaks: How to Fix a Haunting Problem Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager Outline of Topics What is a ghost peak? How to identify ghost peaks and their source How to correct

More information

Tips and Tricks of Injector Maintenance. Abby Folk Agilent GC Technical Support August 2009

Tips and Tricks of Injector Maintenance. Abby Folk Agilent GC Technical Support August 2009 Tips and Tricks of Injector Maintenance Abby Folk Agilent GC Technical Support August 2009 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Have to be able to get things to their gas

More information

Agilent 7697A Headspace Sampler

Agilent 7697A Headspace Sampler Agilent 7697A Headspace Sampler Site Preparation Agilent Technologies Notices Agilent Technologies, Inc. 2012 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation Gas Clean Filters Delivering Clean Gases for GC and GC/MS Operation Gas Clean Filters Fast, leak-free replacement without tools! Each Gas Clean Filter features a unique quick disconnect design which allows

More information

Agilent 5975T LTM GC/MSD

Agilent 5975T LTM GC/MSD Agilent 5975T LTM GC/MSD Site Preparation Guide Agilent Technologies Notices Agilent Technologies, Inc. 2010 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer application Note Gas Chromatography/ Mass Spectrometry Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer Overview A mass spectrometer

More information

Advances in Capillary Column Backflushing

Advances in Capillary Column Backflushing Advances in Capillary Column Backflushing Matthew S. Klee, Ph.D. ISCCE 2010 1 Capillary Flow Technology Traits Ease of use - ruggedness Inertness Usability to > 350 oc Excellent exclusion of air No unpurged

More information

Connectors. SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses. Top Seller SEE STARRED PRODUCTS. VHP Tees & Crosses for Capillary Tubing

Connectors. SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses. Top Seller SEE STARRED PRODUCTS. VHP Tees & Crosses for Capillary Tubing SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses VHP Tees & Crosses for Capillary Tubing VHP Tees & Crosses for 1/16 OD Tubing IDEX Health & Science offers Very High Pressure, designed to bring

More information

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note Gas Chromatography Author Matthew S. Klee Agilent Technologies 2850 Centerville Road Wilmington, DE 19808-1610 USA Abstract

More information

Connecting a SSL/PTV Backflush System

Connecting a SSL/PTV Backflush System This section provides instructions for connecting your SSLBKF/PTVBKF injector modules with pre-column and analytical capillary column into the oven. Refer to the chapters SSLBKF Injector Module and PTVBKF

More information

USER'S GUIDE. Nanoflow Probe. Red Stripe. 3-4mm. ptfe Sleeve. To Injector. ZU1XC Fused Silica TTF115. Fused Silica. ptfe Sleeve

USER'S GUIDE. Nanoflow Probe. Red Stripe. 3-4mm. ptfe Sleeve. To Injector. ZU1XC Fused Silica TTF115. Fused Silica. ptfe Sleeve USER'S GUIDE Nanoflow Probe 3-4mm Red Stripe ptfe Sleeve To Injector ZU1XC Fused Silica 20µm 90µm TTF115 ptfe Sleeve Fused Silica 25µm 375µm Micromass UK Limited Floats Road Wythenshawe M23 9LZ Tel: +44

More information

The Open-Split Capillary Interface. Part No

The Open-Split Capillary Interface. Part No The Open-Split Capillary Interface Part No. 113532 2 INTRODUCTION With the advent of fused silica capillary columns and their high degree of flexibility, it is obviously attractive to be able to take the

More information

UP-F Delrin TM Winged Nut. UP-F PEEK TM Nut. with F-142 PEEK TM Ferrule

UP-F Delrin TM Winged Nut. UP-F PEEK TM Nut. with F-142 PEEK TM Ferrule One Piece or Two? A one-piece fitting is more convenient and less cumbersome, since the ferrule cannot stick in a receiving port and the fitting is more easily found if dropped. With two-piece Fingertight,

More information

Tank Blanketing Pressure Regulators RHPS Series

Tank Blanketing Pressure Regulators RHPS Series www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22

More information

Agilent G Rebuilt Electron Capture Detector

Agilent G Rebuilt Electron Capture Detector Agilent G1533-90790 Rebuilt Electron Capture Detector User Information Agilent Technologies Notices Agilent Technologies, Inc. 2002 No part of this manual may be reproduced in any form or by any means

More information

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs. Laboratory Hardware Custom Gas Chromatography Solutions Custom solutions for your analytical needs. Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions for advanced chromatography

More information

Agilent 7697A Headspace Sampler

Agilent 7697A Headspace Sampler Agilent 7697A Headspace Sampler Data Sheet Overview The Agilent 7697A Headspace Sampler is part of Agilent s line of gas chromatography products. The 7697A based on the architecture of the market-leading

More information

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere! The portable Gas Chromatograph is now more versatile than ever. DPS Instruments is pleased to present the newest Portable Companion 2 Gas Chromatograph with room for 2 Detectors. The Companion 2 GC was

More information

STANDARD OPERATING PROCEDURES

STANDARD OPERATING PROCEDURES PAGE: 1 of 9 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE 3.1 Canister Receipt 3.2 Canister Storage 4.0 INTERFERENCE AND POTENTIAL PROBLEMS

More information

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results. Laboratory Hardware Custom Gas Chromatography Solutions Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions

More information

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax: 2 Table Of Contents 1. Introduction 3 2. About this Manual 3 3. Contacting YZ Systems 3 4. Vessel Components 4 5. Specifications 5 6. Application 6 7. Theory of Operation 7 8. DuraSite Installation & Use

More information

CP-3800 GC Getting Started Manual

CP-3800 GC Getting Started Manual CP-3800 GC Getting Started Manual Getting Started Installation Basic Operation Maintenance Parts and Supplies Varian, Inc. 2700 Mitchell Drive Walnut Creek, CA 94598-1675/usa Varian, Inc. 1999 Printed

More information

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Your local gas generation partner. Precision series Modular gas generation solution for GC. Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,

More information

be present throughout these services; otherwise, they will miss important operational, maintenance and safety information.

be present throughout these services; otherwise, they will miss important operational, maintenance and safety information. Thank you for purchasing an Agilent Instrument. To get you started and to assure a successful and timely installation of your 9000 GC, please refer to this site prep checklist. Correct site preparation

More information

Agilent 1220 Infinity II LC Mobile Upgrade Kit

Agilent 1220 Infinity II LC Mobile Upgrade Kit Agilent 1220 Infinity II LC Mobile Upgrade Kit Note 1220 Infinity II LC Mobile Upgrade Kit This note describes the procedures to install an Mobile Upgrade kit to an existing Agilent 1220 Infinity II LC.

More information

Description Advanced Features Typical Applications

Description Advanced Features Typical Applications Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied

More information

3 Flow and Pressure Control

3 Flow and Pressure Control 3 Hydrogen shutdown Column shutdown Turning gas flows on and off EPC-controlled streams NonEPC-controlled streams Electronic Pneumatic Control (EPC) Interpreting flow and pressure readings Configuration

More information

A Column-Flow Independent Configuration for QuickSwap. Application. Authors. Abstract. Introduction

A Column-Flow Independent Configuration for QuickSwap. Application. Authors. Abstract. Introduction A Column-Flow Independent Configuration for QuickSwap Application Authors Matthew S. Klee and Bruce Quimby Agilent Technologies, Inc. 80 Centerville Road Wilmington, DE 08 USA Abstract As can be seen from

More information

M/s. Thermo fisher Scientific

M/s. Thermo fisher Scientific CLARIFICATIONS AND RESPONSES IN THE PRE BID MEETING HELD ON 19 TH AUGUST 2013 IN OUR COMMITTEE ROOM FOR THE PROCUREMENT OF DIOXIN ANALYSER (GC-MS/MS) File No : PUR/IMP/178/14 Description of Item : DIOXIN

More information

Impact of Air Leaks on the Productivity of GC and GC/MS Systems

Impact of Air Leaks on the Productivity of GC and GC/MS Systems Impact of Air Leaks on the Productivity of GC and GC/MS Systems Application Note Environmental Author Ken Lynam Agilent Technologies, Inc. Abstract Agilent 7890A GC dual-channel FID, Agilent 7890B GC,

More information

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A. Gas Lines Technical Manual Sumitomo (SHI) Cryogenics of America, Inc. 1833 Vultee Street Allentown, PA 18103-4783 U.S.A. Revision F: April 2008 261320A TABLE OF CONTENTS Page DESCRIPTION...1 SPECIFICATIONS...2

More information

MicroJet Cryo-Trap MODEL MJT-1030Ex OPERATION MANUAL

MicroJet Cryo-Trap MODEL MJT-1030Ex OPERATION MANUAL MicroJet Cryo-Trap MODEL MJT-1030Ex OPERATION MANUAL www.frontier-lab.com BEFORE USING THIS DEVICE Thank you for purchasing our MicroJet Cryo-Trap (MJT-1030Ex). We advise you to read this operation manual

More information

ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013

ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013 The SRI ASTM 3612/TOGA/ Dissolved Gas GC configuration ( TOGA GC ) permits measurement of gasses dissolved in water, oil or other liquids, and is based on the requirements of ASTM method 3612, option C,

More information

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE. Gases&Technology FEATURE Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. B Y M A T T H E W M O N A G L E Abstract Bulk gases are often delivered to

More information

GC Accessories Inlet Liners Sky Inlet Liners Other Deactivations Inlet Liner Accessories

GC Accessories Inlet Liners Sky Inlet Liners Other Deactivations Inlet Liner Accessories GC Accessories Inlet Liners Sky Inlet Liners... 175 184 Overview...175 178 For Agilent GCs...179 180 For Bruker/Varian GCs...181 For PerkinElmer GCs...182 For Shimadzu GCs...183 For Thermo Scientific GCs...184

More information

SRI Model H2-40 Hydrogen Generator Operation and Maintenance Nov 2006

SRI Model H2-40 Hydrogen Generator Operation and Maintenance Nov 2006 Nov 2006 Place the H2-40 on a benchtop surface which will not be damaged by water in the event of a leak. Fill a bottle with clean water. Tapwater is OK in most large cities, but bottled drinking water

More information

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds

More information

VACUUM & AIRLESS. Select from Kimble vacuum traps, manifolds, Schlenk tubes, adapters, and bubblers for your vacuum and airless glassware needs.

VACUUM & AIRLESS. Select from Kimble vacuum traps, manifolds, Schlenk tubes, adapters, and bubblers for your vacuum and airless glassware needs. VACUUM & AIRLESS Select from Kimble vacuum traps, manifolds, Schlenk tubes, adapters, and bubblers for your vacuum and airless glassware needs. tions precision glassware solutions precision glassware solutions

More information

ms NoVent II Instruction Booklet

ms NoVent II Instruction Booklet ms NoVent II Instruction Booklet ms NoVent II The ms NoVent II interface is designed to allow column changing or column maintenance to be carried out without the need to shut down the mass spectrometer.

More information

Crimpers and Decappers

Crimpers and Decappers Crimpers and Decappers Adjustable Hand Crimper Adjustable block corrects for differences in septum thicknesses The Adjustable Crimper has an adjustable pressure block in the crimper head that allows crimping

More information

Advancements in Gas Chromatography Analyzers - Keeping up with New Technology. Chuck Runkle Gas Phase Product Specialist ASTS June 2013

Advancements in Gas Chromatography Analyzers - Keeping up with New Technology. Chuck Runkle Gas Phase Product Specialist ASTS June 2013 Advancements in Gas Chromatography Analyzers - Keeping up with New Technology Chuck Runkle Gas Phase Product Specialist ASTS June 0 Capillary Flow Technology -- solves difficult application problems easily

More information

Agilent Inlet EPC Leak Test

Agilent Inlet EPC Leak Test Agilent Inlet EPC Leak Test Gas Chromatographs Instructions Agilent Technologies Notices Agilent Technologies, Inc. 2002 No part of this manual may be reproduced in any form or by any means (including

More information

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump

More information

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion: Automated Determination of Dissolved Gases in Water Anne Jurek Abstract: The RSK-175 standard operating procedure was developed in order to determine the amount of dissolved gas in water. Due to the expansion

More information

Setting a New Standard in Flash Chromatography Performance

Setting a New Standard in Flash Chromatography Performance Setting a New Standard in Flash Chromatography Performance What s New Faster Flow rates, up to 300 ml/min Higher pressures, up to 300 psi (20 bar) Bigger touchscreen, 12 or 15 inches Wider Dynamic Range

More information

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com P5513 Pneumatic Comparison Test Pump Users Manual PN 3963372 November 2010 2010 Fluke Corporation. All

More information

Agilent 7890 Series Gas Chromatograph

Agilent 7890 Series Gas Chromatograph Agilent 7890 Series Gas Chromatograph Advanced Operation Manual Agilent Technologies Notices Agilent Technologies, Inc. 2007-2013 No part of this manual may be reproduced in any form or by any means (including

More information

The instrument will process the samples one by one till all the samples have been cleaned up.

The instrument will process the samples one by one till all the samples have been cleaned up. Table of Contents SPE-01 Cleanup Station... 1 LC-04SP Valve System... 5 LC-04SP Standalone Valve... 10 LC-05 Auto Injector... 12 LC-06 Dosing Pump... 16 LC-08 Column Selector... 17 SPE-01 Cleanup Station

More information

Zebron Gas Management

Zebron Gas Management Zebron www.phenomenex.com/gasmanagement What are the key benefits of Zebron filters and traps? The high adsorption capacity of the Zebron Filters removes contaminants from mobile phase gases, reducing

More information

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

Agilent 1290 Infinity Pump Head Maintenance

Agilent 1290 Infinity Pump Head Maintenance Agilent 1290 Infinity Pump Head Maintenance Technical Note Agilent Technologies Notices Agilent Technologies, Inc. 2012-2015, 2016 No part of this manual may be reproduced in any form or by any means (including

More information

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI Installation, Operation, and Maintenance Manual Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model The information in this manual has been carefully checked for accuracy and is intended

More information

Jaap de Zeeuw Restek Corporation, Middelburg, The Netherlands. Copyrights: Restek Corporation

Jaap de Zeeuw Restek Corporation, Middelburg, The Netherlands. Copyrights: Restek Corporation Using Nitrogen instead of Helium as carrier gas, while maintaining exact the same separation efficiency, retention times, peak elution order, without changing the oven temperature conditions. Jaap de Zeeuw

More information

GCMSD-Headspace Analysis SOP

GCMSD-Headspace Analysis SOP Before you start GCMSD-Headspace Analysis SOP Method and Sequences names are restricted to 50 characters (MSD program will crash otherwise) The GC oven and Injection Ports need to be cooled to 50 oc to

More information

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008 UNITY 2 TM Air Server Series 2 Operators Manual Version 1.0 February 2008 1. Introduction to the Air Server Accessory for UNITY 2...2 1.1. Summary of Operation...2 2. Developing a UNITY 2-Air Server method

More information

CalCheck. Instrument User Manual V1.8

CalCheck. Instrument User Manual V1.8 CalCheck Instrument User Manual V1.8 Unrivalled Part number: 21518 Detection. Part number: 21518 Declaration of conformity Manufacturer:, The Way, Fowlmere, Cambridge, England. SG8 7UJ Product: CalCheck

More information

2 Sentry MCL Installation, Operation & Maintenance

2 Sentry MCL Installation, Operation & Maintenance Gas Liquid & Slurry Solid & Powder Steam & Water Installation, Operation & Maintenance Manual Original Instructions Liquid Sampling Manual Low-Emission Samplers S-GA-IOM-00249-7 11-17 Sentry MCL 966 Blue

More information

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist Thank you for purchasing an Agilent system. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation is

More information

HiQ laboratory gas generators.

HiQ laboratory gas generators. Product information HiQ laboratory gas generators. The convenient alternative for laboratory environments. 02 HiQ laboratory gas generators HiQ laboratory gas generators. Designed with safety and convenience

More information

Rapid and Reliable Detection of Dissolved Gases in Water

Rapid and Reliable Detection of Dissolved Gases in Water Rapid and Reliable Detection of Dissolved Gases in Water Andrea Caruso and Massimo Santoro Thermo Fisher Scientific, Milan, Italy Application Note 005 Key Words Chromeleon CDS, Environmental, Fracking,

More information

The instrument should have a mass range from 2 to 2000 m/z or better Interface

The instrument should have a mass range from 2 to 2000 m/z or better Interface Revised Specifications for Liquid Chromatography Mass Spectrometry (LC-MS/MS ) Triple Quadrupole Specification for Ultra-Fast Liquid Chromatography system Solvent Delivery 1) A quaternary Pump system for

More information

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Your local gas generation partner. Precision series Modular gas generation solution for GC. Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,

More information

Customer Responsibilities

Customer Responsibilities Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS Agilent 7800 ICP-MS Specifications and Typical Performance Fast track metals analysis with Solution-Ready ICP-MS The Solution-Ready Agilent 7800 Quadrupole ICP-MS combines proven, robust hardware, auto-optimization

More information

CORESTA RECOMMENDED METHOD Nº 67

CORESTA RECOMMENDED METHOD Nº 67 CORESTA RECOMMENDED METHOD Nº 67 DETERMINATION OF WATER IN THE MAINSTREAM SMOKE OF CIGARS BY GAS CHROMATOGRAPHIC ANALYSIS (November 2005) 1. FIELD OF APPLICATION The method is applicable to the particulate

More information

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Your local gas generation partner. Precision series Modular gas generation solution for GC. Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,

More information

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

Buck Scientific, Inc.

Buck Scientific, Inc. Buck Scientific, Inc. 910/310 Gas Chromatographs The Buck 910/310 Gas Chromatographs In the lab, the 910-series GCs perform routine industrial analyses and complicated research separations easily, generating

More information

Flexible Metal Hose Products

Flexible Metal Hose Products Flexible Metal Hose Products Specialty Flexible Hose Solutions of Stainless Steel The AEROCOM Advantage Aerocom offers engineered solutions that address specific flexible piping challenges such as vibration,

More information

Agilent 7820A GC. Site Preparation Guide. Agilent Technologies

Agilent 7820A GC. Site Preparation Guide. Agilent Technologies Agilent 7820A GC Site Preparation Guide Agilent Technologies Notices Agilent Technologies, Inc. 2009 No part of this manual may be reproduced in any form or by any means (including electronic storage and

More information

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS 6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS USER MANUAL -1- SI-BARNET DEADWEIGHT TESTER 6000 SERIES Release: S31-0250 Revision: A Date: 05/08/03 MANUFACTURED BY: GE RUSKA RUSKA INSTRUMENT CORPORATION 10311

More information

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler Optimizing Vial Pressurization Parameters for the Analysis of Residual Solvents Using the 7697A Headspace Sampler Application Note Pharmaceuticals Author Roger L Firor Agilent Technologies, Inc.

More information

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310 www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Varian 310 310 LC/MS Manual System INCLUDES: 310-MS LC/MS triple quadrople

More information

ATIS OPERATION MANUAL

ATIS OPERATION MANUAL ATIS OPERATION MANUAL Adsorbent Tube Injector System T702019A 1 Introduction The Adsorbent Tube Injector System (ATIS) is a sample preparation device that provides a quick and efficient way to transfer

More information

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator. RHPS Series RD(H)F40 User Manual Read the complete manual before installing and using the regulator. 2 WARNING Before removing a regulator from the system for service, you must depressurize system purge

More information