Intrinsically explosion-proof and safety barrier introduction

Size: px
Start display at page:

Download "Intrinsically explosion-proof and safety barrier introduction"

Transcription

1 Intrinsically explosion-proof and safety barrier introduction Summary of Topics Page 1. Explosion basic knowledge 1 2. Explosion groups 1 3. Zone classification 2 4. Explosion-proof electrical apparatus design standards 3 5. Explosion-proof mark of different countries 3 6. Explosion-proof type of electrical apparatus 3 7. The basic principles of the intrinsically explosion-proof technology 4 8. The feature of the intrinsically explosion-proof technology 4 9. Intrinsically safety apparatus and associated apparatus Intrinsic safety electrical apparatus type Marking of apparatus The basic components of intrinsically safe explosion-proof system Safety barrier Guidelines for use of devices with intrinsically safe circuits Explosion basic knowledge Explosion is that the material produces a high-speed exothermic reaction. In order to have an explosion, the following three components must be present simultaneously: NO. component interpretation 1 Fuels (flammable substances) Flammable concentrations of gases and vapours or solids which have the potential for igniting an explosion 2 Oxidizers air (21 % Oxygen), pure Oxygen, oxygen releasing compounds (i.e. potassium manganate) 3 Possible sources of ignition hot surfaces, flammable or explosive gases, mechanically generated sparks, electrical installations, transient currents, static electricity, lightning, ultrasonic energy... 4 Explosive limits A mixture is only explosive when its concentration falls within certain material specific limits. These limits are called the upper and lower explosive limits and are listed in according tables. 2. Explosion groups GB ordains that combustible materials are divided into the following classes in accordance with the degree of the inflammable hierarchy. Factory type Classification Representative The min. energy of the gases gases detonating the spark Underground the miner Ⅰ Methane 0.280mJ he factory outside miner ⅡA Propane 0.180mJ Inflammable hierarchy Difficultly Page 1 of 12

2 ⅡB Ethylene 0.060mJ ⅡC Hydrogen, acetylene 0.019mJ easily The United States of America and Canada (NEC500) divide the explosive objects spreading in the air into three classes firstly. The CLASS Ⅰ are gas and vapour. The CLASS Ⅱ is dust. The CLASS Ⅲ is fiber. Then divide the gas and vapour into Group: Class group Representative gases or China/IEC/European countries corresponding dusts class (GB3836.1/IEC /EN50014) A Acetylene ⅡC (Hydrogen, Acetylene) CLASS Ⅰ B Hydrogen ⅡC (Hydrogen, Acetylene) C Ethylene ⅡB (Ethylene) D Methane ⅡA (Propane) E Metal dusts Ⅰ(Methane) CLASS Ⅱ F Coal dusts G Grain dusts To be determined(Ⅲ) CLASS Ⅲ Ⅲ No grouping 3. Zone classification According to EN and EN explosion hazardous areas are divided into zones such as flammables gases, vapours, mists and combustible dust. The classification is based on the likelihood that a dangerous explosive atmosphere occurs. The ATEX directive has re-defined the zone division as follows: Likelihood of an China IEC European explosive Likelihood of an Likelihood of an atmosphere : explosive explosive China occasionally atmosphere: unlikely atmosphere: continuously, for or infrequently - for a Description occasionally long periods or short period only frequently Union European Union constant or long occasionally seldom or short term term corresponds corresponds to corresponds to < 10 to > 1000 h/year h/year h/year gases and Zone zone 0 zone 1 zone 2 vapours classification dusts zone 20 zone 21 zone 22 North America Description Under normal operating conditions, it The flammable gas or continuously, intermittently or vapor will release and periodically exist the flammable gas become dangerous or vapor and the concentrations reach only when the a dangerous level. container rupture, the system is failure or the equipment anomalies Page 2 of 12

3 Zone classification (gases and dusts) Div.1 abnormal operate occasionally. Div.2 4. Explosion-proof electrical apparatus design standards country Standards Code Standards Name Country Standards GB Electrical apparatus for explosive gas atmospheres--part 1:General requirements GB Electrical apparatus for explosive gas atmospheres--part 4:Intrinsic safety IEC IEC :1998 IEC :1999 European Committee for Standardization(CENELEC) EN Intrinsic safety North American (America, Canada) NEC500 Country Standards GB is equivalent to adopting IEC Explosion-proof mark of different countries mark signification Ex Explosion-proof mark of China and IEC EEx European economic community AD Italy MS AE France FLP Great Britain UL FM America E Germany \IEC China National Quality Supervision and Test Centre for Explosion Protected Electrical Products (CQST): CQST is one of the China famous professional testing and certification authorities and engages in safety test, examination and evaluation of Ex electrical products. CQST has made deep research and obtained extensive experience in the field of explosion protection electric safety technique and has a high reputation in the word. CQST has signed the cooperation agreements of mutual acceptance of test results separately with more than ten international wellknown Ex scientific research and test bodies, such as UL (U.S.A.), FM (U.S.A.), PTB (Germany), NEMKO (Norway), testsafe (Australia), CCVE (Russia) and LCIE (France).These cooperation have promoted the international exchange of Ex technique and offered convenient services for sino-foreign Ex product entering into opposing side market. 6. Explosion-proof type of electrical apparatus GB (Electrical apparatus for explosive gas atmospheres) defines as follows: Page 3 of 12

4 code type standards explosion-proof measure application zone d flameproof GB Isolate the ignition source Zone1,Zone2 existing e increased safety GB Try to prevent producing the Zone1,Zone2 ignition source ia intrinsic safe GB Limit the energy of the ignition Zone0-2 source ib intrinsic safe GB Limit the energy of the ignition Zone1,Zone2 source p Pressurized GB Isolate the hazardous substance Zone1,Zone2 and the ignition source o jelly filled GB Isolate the hazardous substance Zone1,Zone2 and the ignition source q sand filled GB Isolate the hazardous substance Zone1,Zone2 and the ignition source n non-sparking GB Try to prevent producing the Zone2 ignition source m pour enveloping GB Try to prevent producing the Zone1,Zone2 ignition source h hermetically sealed GB Try to prevent producing the ignition source Zone1,Zone2 For automatic control and instrumentation, intrinsic safe, flameproof and increased safety types are used commonly. 7. The basic principles of the intrinsically explosion-proof technology In electrical apparatus, electric spark and thermal effect is the main ignition sources that set danger explosive gas off. The intrinsic safety methods are considered protection devices and their function is to avoid possible errors and faults by preventing the transfer of unsafe levels of energy to the hazardous area. Possible faults are: 1) Excessive voltage in the hazardous area. 2) High current levels in the hazardous area (short-circuit). The intrinsic safety method of explosion protection always relates to intrinsically safe circuitry that comprises an intrinsically safe apparatus, an appropriate electrical power source and the connecting cables. In intrinsically safe circuits, an explosive environment cannot be ignited by sparking or a thermal effect when operating normally under prescribed fault conditions. In an intrinsically safe circuit for categroy ia, 2 calculable faults (see definition EN 50020) must not cause an ignition and in category ib only 1 such fault is permissible. Limiting the power supply, total inductance and total capacitance within the intrinsically safe circuitry is the basic principle of the intrinsically safe explosion protection method. The project manager or user has to compare the permissible internal limit values for intrinsically safe electrical apparatus with the permissible connection values of the associated electrical apparatus. 8. The feature of the intrinsically explosion-proof technology Page 4 of 12

5 Intrinsically safe explosion-proof technology is actually a low-power design technology. It is a very good apparatus for the design of industrial automation instrument. Compared with other explosion-proof type, using the explosion-proof electrical technology has following characteristics: 1. Intrinsically electrical apparatus have simple structure, small size, light weight. 2. Installation and maintenance can be with power input. 3. High security and reliability. Do not reduce the security and reliability of the electrical apparatus for outside structural damage. 4. Applicable range is wide range. It is the only explosion-proof technology that can be applied in the zone Intrinsically safety apparatus and associated apparatus a. Intrinsically safety apparatus In the conditions of the national standards, any spark and thermal effects produced by this electric apparatus can not ignite the explosive gas environment It can be used in hazardous area. It can be divided into general electrical apparatus and simple electrical apparatus. General electrical apparatus: Has the energy storage element, need explosion-protection authentication. Such as intrinsically transmitter, approach switch, and so on. Simple electrical apparatus:if Voltage is lower than 1.2V, current is lower than 0.1A,energy is lower than 20uJ or power is lower than 25mW, it is considered as simple electrical apparatus. Do not need explosion-protection authentication, can directly access to the intrinsically explosion-protection system. Typical feature as followers: Internal equivalent inductance Li = 0, Internal equivalent capacitance Ci = 0. Common simple apparatuses are: thermocouples, thermal resistors, resistor, light emitting diode, contact switch, and so on. b. Associated apparatus (safety barrier) It is an apparatus installed in a safety area, connecting the intrinsically electric apparatus and non-intrinsically electric apparatus. Safety barrier limit the energy get in to the hazardous area in the safety rang and ensure that the field equipment, personnel and production are safety. 10. Intrinsic safety electrical apparatus type a. Apparatus groups According to the principle of GB , intrinsic safety electrical apparatus has 2 types as follows: Group interpretation Device Group I For mining underground with a potential hazard due to firedamp and/or combustible dusts. Device Group II For all other locations in which a potentially explosive atmosphere exists. There are three class of A, B and C b. Apparatus Category Intrinsic safety electrical apparatus and associated apparatus can be divided into ia class and ib class according to the places used or connected and the safety standards. Code interpretation Page 5 of 12

6 ia ib Very high level of safety: devices featuring two independent means of protection; even in the event of rare device disturbances, the device remains functional and maintains the requisite level of protection. It can be used in the hazardous areas of zone0, zone1 and zone2. High level of safety: devices featuring one means of protection. Even in the event of frequently occurring device disturbances or equipment faults which normally have to be taken into account the device provides the requisite level of safety. It can be used in the hazardous areas of zone1 and zone2. c. Install temperature class The temperature class indicates the maximum surface temperature of an apparatus and must be lower than the minimum ignition temperature of the flammable material to prevent an ignition. The ignition temperature (defined as the temperature at which a mixture self-ignites during testing) directly relates to the temperature class. see table below. temperature class Maximum surface temperature ignition temperatures of flammable materials T T T T Common explosive gas Hydrogen, acrylonitrile, etc. (46 kinds) Ethane, ethylene, etc. (47 kinds) Petrol, crotonaldehyde, etc. (36 kinds) Acetaldehyde, tetrafluoroethylene, etc. (6 kinds) T carbon disulfide T ethyl nitrate and ethyl nitrite Intrinsically safe equipment for direct installation in hazardous areas requires temperature classification. For associated apparatus temperature classification is not needed. Electrical safety Low High 11. Marking of apparatus Equipment for explosion protected areas must be clearly marked. There are two different types of marking. According to CENELEC marking of an apparatus conforming to EN 50014/20 must provide the following information: Manufacturer s name or trademark Part number EEx-symbol Ignition category (e. g. ia ) Designated group together with the respective subdivision (e. g. IIC) Temperature class or maximum surface temperature (for group II devices only) Page 6 of 12

7 Serial number (may be omitted if space is restricted) Test authority, date and file number X after the test certificate number indicates that special conditions must be met (see certificate for special conditions) An intrinsically safe apparatus could have the following marking: Ex ia ⅡC T6 temperature class explosion group type of protection conform to IEC or chian standard An associated apparatus could have the following marking: [Ex ia]Ⅱc associated apparatus explosion group type of protection conform to IEC or chian standard 12. The basic components of intrinsically safe explosion-proof system Hazardous Area Safe Area Intrinsically Safety apparatus cable Associated apparatus (safety barrier) Centralized Control System/ PLC/ Operation Terminal Intrinsically performance certification parameter of intrinsically electrical apparatus: 1 Maximal Input Voltage (Ui):The maximal voltage put on the intrinsically safety apparatus, and can not lead to the intrinsically performance failure (AC peak or DC). 2 Maximal Input Current (Ii):The maximal current put on the intrinsically safety apparatus, and can not lead to the intrinsically performance failure (AC peak or DC). 3 Maximum Input Power (Pi):The intrinsically current maximum input power that may consume in the intrinsically safety apparatus inside when the intrinsically safety apparatus connects with the external power and do not lead to the intrinsically performances failure. Page 7 of 12

8 4 Maximum internal Equivalent Capacitance (Ci): Total equivalent capacitance inductance appearing by the intrinsically safety apparatus. 5 Maximum internal Equivalent Inductance (Li): Total equivalent internal inductance appearing by the intrinsically safety apparatus. Intrinsically performance certification parameter of associated apparatus (safety barrier): 1 Maximal Voltage (AC RMS or DC Um):The maximal voltage put on the associated apparatus (safety barrier), and can not lead to the intrinsically performance failure 2 Maximum Output Voltage (Uo):The maximum Output Voltage that may appear in the intrinsically current when open circuit and the intrinsically safety apparatus voltage (including the Um and Ui ) is maximal (AC peak or DC). 3 Maximum Output Current (Io):The intrinsically current maximum current that come from the intrinsically safety apparatus (AC peak or DC). 4 Maximum Output Power (Po):The intrinsically current maximum power that can from the intrinsically safety apparatus. 5 Maximum external Capacitance (Co):The intrinsically current maximum capacitance that can connects to the intrinsically safety apparatus and do not lead to the intrinsically performances failure. 6 Maximum external Inductance (Lo):The intrinsically current maximum inductance that can connects to the intrinsically safety apparatus and do not lead to the intrinsically performances failure. Patch cable:intrinsically cable is a low capacitance and low inductance cable. Compared with other cable has excellent shielding and anti-interference performance. It suits for explosion hazardous area and having high explosion-proof security requirement. Its intrinsically performance as follows: Maximum distribution capacitance that the cable allow: Cc = Ck * L Maximum distribution inductance that the cable allow: Lc = Lk * L Ck Distributed capacitance per unit length of the cable Lk Distributed inductance per unit length of the cable L The actual length of the cable The various configuration of the intrinsically explosion-protection system must meet the following conditions: 1. The explosion-protection mark class of the intrinsically safety apparatus can not higher than the associated apparatus (safety barrier). 2. Authentication parameters have to satisfy the following inequality between the associated apparatus, intrinsically safety apparatus and the cable. Associated apparatus Demonstration of intrinsic safety apparatus Intrinsically safe apparatus + cable Uo Ui Io Ii Po Pi Co Ci + Cc Lo Li + Lc Page 8 of 12

9 13. Safety barrier Some special industrial fields not only need the two-wire transmission for signal isolation and providing power input, but also need the explosion-protection performance about safety spark-proof and reliably avoiding the high voltage and signal contacting. Using the current and voltage double limiting loop, limiting the energy getting into the hazardous area lower than the ration, these can improve the explosion-protection performance of the intrinsically system, at the same time increase the anti-interference ability greatly enhanced the reliability greatly of the system. These field products having specific function are safety barrier. Safety barrier is used in the design of an intrinsically explosion-proof system. It is installed in a safety area. Safety barrier is an apparatus with intrinsically current and non-intrinsically. These current limits the energy get in to the hazardous area by limiting the current and limiting the voltage, then avoid the hazardous energy enter into the hazardous area. Safety barrier is named associated apparatus, it is an important component of the intrinsically system. Because the safety barrier is designed as an interface between the field apparatus and the control room apparatus, no matter the control room apparatus is in normal or fault, safety barrier both can ensure the energy send to the field through it is intrinsically safe. According to signal direction, Safety barrier have two types as follow: Ⅰ. Detection type safety barrier: Detection type safety barriers usually are used with the transmitter at hazardous area. The functions as follow: a. Convert the signal from the hazardous area to standard current or voltage signal, isolate, and transmit it to safety area. B. Limit the risk energy getting into s hazardous area from intrinsic safety terminal. C. Give isolation power distribution to the field transmitter. Ⅱ. Operation type safety barrier: Operation type safety barrier usually are used with the current to pneumatic converter or electric appliance valve positioner at hazardous area. The functions as follow: a. Isolate and transmit the current signal from the safety area to the hazardous area, and driver the field actuating element (current to pneumatic converter ), etc. b. Limit the risk energy getting into s hazardous area from intrinsic safety terminal. C. Give isolation power distribution to the safety area. Safety barrier can be devided into zener safety barrier and isolation safety barrier according to construction. Ⅰ. Zener safety barrier The current uses the rapid fuse, current-limiting resistance or voltage-limiting diode to limit the input energy, thus ensue the energy output to the hazardous area. The principle as follows: Hazardous Area Safe Area Zener safety barrier have simple principle. Its current can achieve easily and the price is cheap. But the Page 9 of 12

10 application reliability is affected greatly for its principle defect and this limits its application range. The reason as follows: a. Installation location must have reliable ground system, and the ground must be less than 1Ω, otherwise it would lose the explosion-protection performance and reduce signal anti-interference capacity directly, affect the stability of the system. b. The instrument from hazardous area must is isolation type, or the signal connected to the ground by the ground terminal of the zener safety barrier can not transmit correctly, and because of signal grounding, it will reduce signal anti-interference capacity directly, affect the stability of the system. c. Zener safety barrier has greater impact on the power supply, at the same time it can be damaged easily for the instability of the power supply. d. Using zener safety barrier, signal negative pole all need to the intrinsically ground, it will reduce signal anti-interference capacity directly, affect the stability of the system., the impact on the DCS system is sharp prominent. Ⅱ. Isolation safety barrier Isolation safety barrier is composed of limiting energy unit, isolation unit, signal process unit, power supply unit, etc. The principle as follows: Hazardous Area Safe Area Isolation safety barrier not only has limiting energy function, but also has isolation function, at the same time in accordance with intrinsically limiting energy requirements. Compared to zener safety barrier, although the price is slightly higher, but its others outstanding advantage give more benefits to user. a. Transformer isolated barriers do not require grounding, because the transformer in the barrier galvanically isolates the hazardous area from the safe area. b. Transformer isolated barriers have an internal voltage regulator. The function necessary to the application is thereby assured.a regulated power supply is only necessary for Zener barriers. If the power supply for Zener barriers is too low, the field device can no longer operate. The same applies to: If the power supply becomes too high, the Zener diodes divert the current and the fuse blows when the current exceeds its maximum rating. c. Any process monitoring signal circuit (ma- or mv-signal) that is connected to a transformer isolated barrier is not grounded. In contrast to this, Zener barriers require a suitable ground. From an instrumentation point of view this is best achieved through a quasi ungrounded system. d. Transformer isolated barriers from MORNSUN can be repaired; Zener barriers cannot, because they are filled with an epoxy resin. e. Transformer isolated barriers have an internal current limit. The fuse is not activated if there is a short circuit at the exterminal. f. Instead of using diagrams and Ohm's Law to determine the proper barrier, each transformer isolated barrier is designed for special applications (i. e. 4 ma~20 ma amplifier, thermocouple amplifier, solenoid drivers, etc.) limiting energy unit Isolation unit signal process unit Page 10 of 12

11 According to the function, the types of safety barrier commonly used are as follows: switch safety barrier, analog safety barrier, digital safety barrier, resistance thermometry safety barrier, thermocouple safety barrier, frequency safety barrier, and so on. 14. Guidelines for use of devices with intrinsically safe circuits The principle of selecting the intrinsic safety electrical apparatus Simple electrical apparatus: According to the principle of GB about explosion-protection standards, if voltage is lower than 1.2V, current is lower than 0.1A, energy is lower than 20uJ or power is lower than 25mW, it is considered as simple electrical apparatus. Typical feature as followers: Internal equivalent inductance Li = 0, Internal equivalent capacitance Ci = 0. Common simple apparatuses are: thermocouples, thermal resistors, ph electrode, strain gauge, switch, and so on. General electrical apparatus: a. The design whether or not in accordance with the GB and GB requirements and if the electrical apparatus had been approved by the explosion-proof inspection agency which was authorized by the national. b. If the explosion-proof mark class is applicable to the safety requirements of the hazardous area. c. Clear the authentication parameters of Ui, Ii, Pi, Ci and Li. d. If intrinsically safety current ground or if it is isolated effectively between the grounding intrinsically current and the safety barrier interface current. e. What is the method of the signal transmission? f. Clear the minimum operating voltage and loop normal operating current of the intrinsically electrical apparatus. The principle of selecting the safety barrier a. Safety barrier s explosion-proof mark class is not lower than the class of the intrinsically field apparatus. b. Make sure the end and circuit resistances can meet the minimum operating voltage of the intrinsically field apparatus. c. Safety barrier s safety parameters of the intrinsically port can conform to Uo Ui, Io Ii, Co Ci+Cc, Lo Li+Lc. d. The safety and the signal transmission mode between the safety barrier and the intrinsically field instrument must be best match. e. Do protection well. Avoid leakage current of the safety barrier affects the normal operation of the field intrinsically safety apparatus. f. Safety barrier have two types: one is zener safety barrier, the other is isolation safety barrier. The principle of selecting the cables The governing regulations cover installation of intrinsically safe circuits, mounting to external connections, cable characteristics and cable installation. Cables and terminals with intrinsically safe circuits must be marked and separated from nonintrinsically safe circuits or feature appropriate isolation (> VAC). Following an excerpt from the requirements according to EN : a. Protection against external electrical or magnetic fields (e.g. power current cables). b. Prevent conductor splicing of fine wires through wire sleeves. c. Min. cross section of 0.1 mm (also single wires of a conductor). d. Protection against damaging (mechanical, chemical, thermic...) e. Armouring, metal cladding, shielding of cables and lines Page 11 of 12

12 f. Common use of single-core nonsheathed cables of intrinsically and nonsafe circuits in one line is not permitted. g. Separate error assessment when using multi-conductor cables and lines. h. When marking cables by colour, light-blue must be used. Installation of cables Electrical cables are the connection between field and interface devices and are important functional components of an automation system. Therefore it is advisable to observe some frame conditions when installing cables. Cables must be protected against negative environmental influences. Chemical resistance, temperature rating, resistance against ultraviolet radiation and applicable operation standards are just some of the parameters which should be taken into account. By choosing an appropriate installation method it is possible to prevent damages, e.g. through vehicles. When connected to field devices, the cable should be routed in a conduit. If connected to vibrating machines or moving parts, some extra cable should be added as a reserve. The minimum bending radius must also be observed. Cable manufacturers provide information on cable installation and valuable installation hints. Data integrity and reliability depend strongly on the cable types and installation methods. Sensor cables should always be installed separately from the power cables. Electromagnetic interferences must also be avoided. Cable connections to motors which are controlled via frequency converters should be protected according to the manufacturer s safety specifications. If long cables are needed, it is recommended to use shielded and earthed cables. The line resistance of sensors may not exceed 50 Ω (EN ); the maximum cable length is determined by the cable' cross-section: R S L= δ R = line resistance [Ω] S = cable cross-section [mm 2 ] δ = resistivity [Ω mm 2 /m] L = cable length [m] Page 12 of 12

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature

More information

The Omron STI Hazardous Location

The Omron STI Hazardous Location Hazardous Location Rating Systems for Interlock Switches The Omron STI Hazardous Location Rated Safety Interlock Switches presented in this catalog are classified by the European standard as Ex, ExdIIc

More information

Hazardous (Classified) Locations

Hazardous (Classified) Locations Hazardous (Classified) Locations Presented by: John Chambers UL HazLoc operations Presented at: Safety & You in 2002 2002 Safety Conference Flexible Packaging Association (FPA) 1 AREA CLASSIFICATIONS Class

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

Session #: Selection of Explosion Protected Equipment for Hazardous Locations

Session #: Selection of Explosion Protected Equipment for Hazardous Locations Abstract Session #: (Arial 16) Selection of Explosion Protected Equipment for Hazardous Locations Pieter Coetzee Explosion Prevention Consultant Registered person How can we mitigate the risks of explosions

More information

IA CERTIFICATE (Revision 3 Revised for Annual Review) Hazel Grove Stockport Cheshire SK14 6NG United Kingdom

IA CERTIFICATE (Revision 3 Revised for Annual Review) Hazel Grove Stockport Cheshire SK14 6NG United Kingdom Certificate Number: MASC MS/11-358X Issued: 22 September 2014 Expire: 22 September 2015 Page: 1 of 5 IA CERTIFICATE (Revision 3 Revised for Annual Review) IN TERMS OF REGULATION 21.17.2 OF THE MINERALS

More information

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] 12th Edition 1 1. Introduction Thank you for purchasing the DPharp electronic pressure transmitter. This manual

More information

Technical Data Sheet MF010-O-LC

Technical Data Sheet MF010-O-LC Technical Data Sheet MF010-O-LC - 1 - 1. Properties The oxygen measuring system MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 C. It is particularly suitable for the

More information

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching

More information

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS 1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS EXPLOSION PROTECTION In addition to the type approval and certification of industrial weighing systems concerned with accuracy, equipment that is also

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting

More information

Technical Data. General specifications. Rated operating distance s n 2 mm

Technical Data. General specifications. Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 2 mm Installation

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 10 mm flush Shielded PUR cable for oil and gas sector Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching function Normally closed (NC) Output type

More information

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9 BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9 Issue: 9 22 nd March 2013 2 CONTENTS 1. Description 2. Operation 3. Intrinsic Safety Certification 3.1 ATEX certificate

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 6 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm 0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush

More information

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review) Certificate Number: MASC MS/11-127X Issue: 09 October 2017 Expire: 09 October 2020 Page: 1 of 5 IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

More information

II 2G EEx ia IIC T6. Ignition protection class

II 2G EEx ia IIC T6. Ignition protection class ATEX General information According to 94/9/EC, a device that is to be used in an environment at risk of explosion may only be brought into the market if it satisfies the standards specified in the norm.

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element

More information

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry Operating Instructions for Intrinsically Safe ressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry Contents 1. Introduction 2. Abbreviations, symbols 3. Important

More information

Pressure switch, Differential pressure switch and Thermostat RT-E

Pressure switch, Differential pressure switch and Thermostat RT-E Data sheet Pressure switch, Differential pressure switch and Thermostat RT-E The RT-E series consist of pressure and differential pressure switches as well as thermostats. The units are designed for industrial

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output

More information

Mechanical pressure switches

Mechanical pressure switches 18 Technical features / Advantages Diecast aluminium housing IP 54 or IP 65 version also available Wall mounting or directly on the pressure line Switching element (microswitch) Lead sealable setpoint

More information

Intrinsic safety 101 hazardous locations

Intrinsic safety 101 hazardous locations Intrinsic safety 101 hazardous locations Protection methods, containment, segregation, and prevention By Robert Schosker This article answers the question, Why worry about hazardous locations? The area

More information

Pressure Switches Application Guideline

Pressure Switches Application Guideline Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Nonferrous targets Application Danger! In safety-related applications the sensor must be operated with a qualified fail

More information

IE073: Intrinsic Safety, Galvanic Isolation and Zener Barriers Technology & Applications

IE073: Intrinsic Safety, Galvanic Isolation and Zener Barriers Technology & Applications IE073: Intrinsic Safety, Galvanic Isolation and Zener Barriers Technology & Applications IE073 Rev.001 CMCT COURSE OUTLINE Page 1 of 5 Training Description: The hazardous-area circuits 'float' i.e. is

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable

More information

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use Data sheet Katharometers The ideal equipment for Process Monitoring and Control Designed for continuous industrial use Long working life Suitable for flammable gases CENELEC certified (ATEX) to EExia IIC

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable

More information

I/P Transducer Positioner Module

I/P Transducer Positioner Module I/P Transducer Positioner Module VRC P/N: 7958032 Installation, Operation and Maintenance Instructions 2.09 [53.1] 1.30 [32.9] 2.97 [75.5] 0.78 [19.8] 0.18 [4.4] 1.42 [36.1] n.18 MOUNTING HOLES (2) PLACES

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up

More information

Operating Instructions of BROSA tension load cells, types 0111, 0113

Operating Instructions of BROSA tension load cells, types 0111, 0113 Operating Instructions of BROSA tension load cells, types 0, 03. Description of BROSA tension load cells. Structure and function The BROSA type 0 and 03 tension load cells transmit and measure the tensile

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2419437 Master Contract: 203012 Issued to: ABB Automation Products GmbH 72 Schillerstrasse Minden, 32425 Germany Attention: Ralf Schaffer The products listed below

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 9 5 14 40 35 11 9 5.4 M20 x 1.5 0102 S Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies

More information

Hazardous Location Coding System - For Division. Class I / II / III, Division 1 / 2 Type of Protection. XP = Explosionproof

Hazardous Location Coding System - For Division. Class I / II / III, Division 1 / 2 Type of Protection. XP = Explosionproof Hazardous Location Equipment - Canada Equipment listed in this category for Hazardous Locations is also suitable for installations in areas that are non-hazardous locations and, unless referenced in the

More information

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB Air Sensor SAC Ex Manual AQ Elteknik AB ATEX Air Sensor SAC Ex ATEX Certified model Manual version 2.1 April 2014 AQ Elteknik AB 2 Table of contents 1. Manufacturer information... 4 Manufacture Declaration

More information

Pressure control, differental pressure control and thermostat Type RT

Pressure control, differental pressure control and thermostat Type RT MAKING MODERN LIVING POSSIBLE Technical brochure Pressure control, differental pressure control and thermostat Type RT Hydrocarbons www.danfoss.com/hydrocarbons Contents Page Introduction...3 Approvals...3

More information

DK46 - DK800 Supplementary instructions

DK46 - DK800 Supplementary instructions DK46 - DK800 Supplementary instructions Variable area flowmeter Device category II2G with electrical internals Additional Ex manual KROHNE CONTENTS DK46 - DK800 1 Safety instructions 3 1.1 General... 3

More information

Instruction Manual for Intrinsically Safe - Reed Switches

Instruction Manual for Intrinsically Safe - Reed Switches Instruction Manual for Intrinsically Safe - Reed Switches Option Code: -1S2-IS-LED or -2S2-IS-LED -1S2-IS or -2S2-IS ATEX RCM Industries, Inc. Direct Reading Differential Pressure Flowmeters 110 Mason

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 9 5 40 35 14 11 9 5.4 M20 x 1.5 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies machinery

More information

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)

More information

FLAMMABLE GAS SENSOR/TRANSMITTER

FLAMMABLE GAS SENSOR/TRANSMITTER FLAMMABLE GAS SENSOR/TRANSMITTER Plant safety protection for flammable gases. F E A T U R E S Fixed gas monitoring for point source hazards and perimeter protection in arduous duty and exposed locations.

More information

WHITE PAPER on Explosion Proof and Intrinsic Safety Solutions. Oct. 2013

WHITE PAPER on Explosion Proof and Intrinsic Safety Solutions. Oct. 2013 WHITE PAPER on Explosion Proof and Intrinsic Safety Solutions Oct. 2013 TABLE OF CONTENTS Abstract... 3 Abbreviations... 4 Introduction to Standards... 5 Protection Layers... 7 Simple Devices... 7 Mechanical

More information

TechNote FM APPROVAL: HAZARDOUS LOCATION EQUIPMENT CLASSIFICATION

TechNote FM APPROVAL: HAZARDOUS LOCATION EQUIPMENT CLASSIFICATION TechNote FM APPROVAL: HAZARDOUS LOCATION EQUIPMENT CLASSIFICATION Equipment listed in this guide for Hazardous (Classified) Locations is also suitable for installations in areas that are unclassified locations

More information

Magnetic level switch type MR783 Instruction Manual

Magnetic level switch type MR783 Instruction Manual Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2

More information

Pressure switch KP-E. Data sheet

Pressure switch KP-E. Data sheet Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2. Introduction 1 Safety instructions 2 SITRANS Pressure transmitter SITRANS P, Z series for gauge and absolute pressure 7MF1564 Description 3 Assembly and connection 4 Technical data 5 Dimensional drawings

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 7 36 5 33.5 9 5.4 30 65 0102 Model Number Features Direct mounting on standard actuators Fixed setting Satisfies machinery directive Compact and stable housing EC-Type Examination Certificate

More information

Level transmitter LT 100

Level transmitter LT 100 KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

Intrinsically safe solenoid valves on/off controls - ATEX certification

Intrinsically safe solenoid valves on/off controls - ATEX certification www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display. Display Thermo, Inc. Instruction Manual English TP-5 Display TP-7 Display TP-8 1-1 Thermo, Inc. Instructions for use- Models TP-5, TP-7, and TP-8 The manual describes basic function and use of Thermo instruments

More information

Electrical Equipment and Installations in Hazardous Areas. Univerza v Ljubljani Fakulteta za elektrotehniko

Electrical Equipment and Installations in Hazardous Areas. Univerza v Ljubljani Fakulteta za elektrotehniko Univerza v Ljubljani Fakulteta za elektrotehniko Electrical Equipment and Installations in Hazardous Areas Student: Tiago da Silva Oliveira; Student Number: 70080035; Subject: Electrical Installations

More information

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Application Single-acting positioner for attachment to pneumatic control valves. Supplied with either an electric input signal from

More information

RTD temperature probes

RTD temperature probes RTD temperature probes Ex i for use in areas with an explosion hazard (Ex areas) Persons concerned: Experienced professional electricians as per EU Directive 1999/92/EC and trained personnel Operating

More information

CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS IN GAS UTILITY AREAS. Gerry Pickens

CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS IN GAS UTILITY AREAS. Gerry Pickens CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS IN GAS UTILITY AREAS Gerry Pickens Atmos Energy 810 Crescent Centre Drive Franklin, TN 37067 The National Electrical Code (NEC) defines hazardous

More information

BASIC NATIONAL ELECTRIC CODE APPLICABLE TO MEASUREMENT. Gerry Pickens. Atmos Energy 810 Crescent Centre Drive Franklin, TN 37067

BASIC NATIONAL ELECTRIC CODE APPLICABLE TO MEASUREMENT. Gerry Pickens. Atmos Energy 810 Crescent Centre Drive Franklin, TN 37067 BASIC NATIONAL ELECTRIC CODE APPLICABLE TO MEASUREMENT The National Electrical Code (NEC) defines hazardous locations as those areas "where fire or explosion hazards may exist due to flammable gases or

More information

Guidelines to the standard IEC60601

Guidelines to the standard IEC60601 EUROPEAN POWER SUPPLY MANUFACTURERS ASSOCIATION (Visit the EPSMA website at www.epsma.org) Medical Approvals for Power Supplies Guidelines to the standard IEC60601 Revision Date: 2009-09-12 This document

More information

Liquid level instruments BM 24 /BM 51

Liquid level instruments BM 24 /BM 51 KROHNE 09/2001 7.02362.21.00 GR/PRINTO Liquid level instruments / Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

GAS FUEL VALVE FORM AGV5 OM 8-03

GAS FUEL VALVE FORM AGV5 OM 8-03 ALTRONIC AGV5 OPERATING MANUAL GAS FUEL VALVE FORM AGV5 OM 8-03 WARNING: DEVIATION FROM THESE INSTALLATION INSTRUCTIONS MAY LEAD TO IMPROPER ENGINE OPERATION WHICH COULD CAUSE PERSONAL INJURY TO OPERATORS

More information

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres Page 1 of 7 Title Plan electrical installations for explosive atmospheres Level 5 Credits 8 Purpose This unit standard is intended for use in the training and assessment of people who work with electrical

More information

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at

More information

Wireless I/O, Connecting Remote Sensors in a Wide Range of Environments

Wireless I/O, Connecting Remote Sensors in a Wide Range of Environments Gas Well Deliquification Workshop Sheraton Hotel, February 19 22, 2012 Wireless I/O, Connecting Remote Sensors in a Wide Range of Environments Glenn Longley, Sr. Product Manager FreeWave Technologies Agenda

More information

Instruction Manual Differential Pressure Transmitter

Instruction Manual Differential Pressure Transmitter DE61 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

Process Instrumentation. Product Guide. Registered Quality System to ISO 9001

Process Instrumentation. Product Guide. Registered Quality System to ISO 9001 Process Instrumentation Product Guide Registered Quality System to ISO 9001 SORis committed to and understands the demanding requirements of the process industry. We design, develop and manufacture the

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20

More information

Technical Explanation

Technical Explanation Technical Explanation for ESI Pressure Sensors Technical Explanation What is a pressure transmitter? A pressure transmitter (also called pressure transducer or pressure converter) is a component used to

More information

Hazardous Location Coding System - NEC 500. Type of Protection. XP = Explosionproof. IS = Intrinsically Safe Apparatus

Hazardous Location Coding System - NEC 500. Type of Protection. XP = Explosionproof. IS = Intrinsically Safe Apparatus Hazardous Location Equipment - United States Equipment listed in this category for Hazardous (Classified) Locations is also suitable for installations in areas that are unclassified locations and, unless

More information

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0. Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:

More information

MODEL GT820 OXYGEN SENSOR

MODEL GT820 OXYGEN SENSOR INSTRUCTION MANUAL MODEL GT820 OXYGEN SENSOR 70046 The information and technical data disclosed by this document may be used and disseminated only for the purposes and to the extent specifically authorized

More information

Gas Network Craftsperson

Gas Network Craftsperson Gas Network Craftsperson Unit EIAU06 Maintaining Instrumentation and Control Equipment Circuits This assessment specification has been developed as part of the network maintenance craftsperson standard

More information

A i r c r a f t E l e c t r i c a l S y s t e m s ( 1 2 B )

A i r c r a f t E l e c t r i c a l S y s t e m s ( 1 2 B ) 8 5 4 9 A i r c r a f t E l e c t r i c a l S y s t e m s ( 1 2 B ) 40S/40E/40M An Aviation and Aerospace Technologies Course 8 5 4 9 : A i r c r a f t E l e c t r i c a l S y s t e m s ( 1 2 B ) 4 0

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. AK100 Series ATEX compliant gas analyzer system for hydrogen-cooled alternators

ABB MEASUREMENT & ANALYTICS DATA SHEET. AK100 Series ATEX compliant gas analyzer system for hydrogen-cooled alternators ABB MEASUREMENT & ANALYTICS DATA SHEET AK100 Series ATEX compliant gas analyzer system for hydrogen-cooled alternators AK100 S E RIE S ATEX COMP LI AN T GAS ANALY ZE R SYSTE M DS/AK100-E N RE V. O Measurement

More information

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Air Sensor. FCS Ex. Manual. AQ Elteknik AB Air Sensor FCS Ex Manual AQ Elteknik AB Air Sensor Model FCS Ex Manual version 2.0 Oct 2010 AQ Elteknik AB AQ Elteknik AB Air Sensor Manual 2 Table of contents 1. Manufacturer information... 4 Manufacture

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL

More information

AK100 Series ATEX Compliant Gas Analyzer System for Hydrogen-cooled Alternators

AK100 Series ATEX Compliant Gas Analyzer System for Hydrogen-cooled Alternators Data sheet DS/AK EN Rev. J AK Series ATEX Compliant Gas Analyzer System for Hydrogen-cooled Alternators Superior technology and quality from the world leader in hydrogen measurement ATEX compliant intrinsically

More information

(Certification N:o VTT 08 ATEX 066 or IECEx VTT )

(Certification N:o VTT 08 ATEX 066 or IECEx VTT ) (Certification N:o VTT 08 ATEX 066 or IECEx VTT 12.0009) Thank you for choosing Slam Hornet portable work light for your job site. Purpose of this manual is to provide you all the necessary safety and

More information

Monitoring device NTS 30

Monitoring device NTS 30 P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit

More information

Electro-Pneumatic Converter YT-940 SERIES

Electro-Pneumatic Converter YT-940 SERIES Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product

More information

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions

More information

Temperature gauge Installation Guide

Temperature gauge Installation Guide Temperature gauge Installation Guide improper functioning, or damage. Additional information can be found at: CAUTION: Read this installation guide carefully before unpacking the temperature gauge. Improper

More information

PRINCIPLES OF EXPLOSION PROTECTION

PRINCIPLES OF EXPLOSION PROTECTION PRINCIPLES OF EXPLOSION PROTECTION Contact Details... 19 Definitions... 1 Explosion proof apparatus... 14 Hazard zone classifications... 4 Installations... 15 Introduction... 1 Maintenance... 17 Primary

More information

VG5 Supplementary instructions

VG5 Supplementary instructions VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...

More information

Technical Explanation

Technical Explanation Technical Explanation for ESI Pressure Sensors Technical Explanation What is a pressure transmitter? A pressure transmitter (also called pressure transducer or pressure converter) is a component used to

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Supplementary Operator s Manual 42/24-14 EN Rev. 3 Advance Optima Continuous Gas Analyzers AO2000 Series with Uras26, Magnos206, Caldos25, Caldos27 Designed per Category 3G for Measurement of Flammable Gases ( Safety Concept ) and Non-flammable Gases Supplementary

More information

Coriolis Mass Flow Meter

Coriolis Mass Flow Meter Coriolis Mass Flow Meter TMFW Series Mini Type Coriolis Mass Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com;

More information

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm) Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless

More information

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres Page 1 of 8 Title Conduct detailed inspection of electrical installations for explosive atmospheres Level 5 Credits 5 Purpose This unit standard is intended for use in the training and assessment of people

More information

NZQA registered unit standard version 3 Page 1 of 6

NZQA registered unit standard version 3 Page 1 of 6 Page 1 of 6 Title Report on the integrity of explosion-protected electrical apparatus in explosive atmospheres Level 3 Credits 3 Purpose This unit standard covers the explosion-protection aspects of plant

More information

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring

More information

Polymer Electric. Product information. Normally Closed Safety Edges SL/NC II. GmbH & Co. KG. Polymer Electric

Polymer Electric. Product information. Normally Closed Safety Edges SL/NC II. GmbH & Co. KG. Polymer Electric Polymer Electric Product information Normally Closed Safety Edges SL/NC II GmbH & Co. KG Polymer Electric Örlinger Straße 1 3 89073 Ulm GERMANY Tel. 49 731 2061-0 Fax 49 731 2061-222 E-Mail: info.ulm@mayser.de

More information