1 Technical specifications
|
|
- Jordan Allison
- 5 years ago
- Views:
Transcription
1 Siemens AG 06 SITRANS P S III for gauge/absolute pressure, with front-flush diaphragm Technical specifications SITRANS P S III series for gauge and absolute pressure, with front-flush diaphragm Input of gauge pressure, with front-flush diaphragm Measured variable Gauge pressure, front-flush Span (continuously adjustable) or measuring range, max. operating pressure and max. test pressure HART PROFIBUS PA/ FOUNATION Fieldbus Span Nominal measuring range bar kpa psi bar kpa psi bar kpa psi bar kpa psi bar 00 kpa 4.5 psi 4bar 400 kpa 58 psi 6 bar 600 kpa 3 psi 63 bar 6300 kpa 94 psi Lower measuring limit Measuring cell with silicone oil filling 00 mbar a/0 kpa a/.45 psia Measuring cell with inert filling liquid 00 mbar a/0 kpa a/.45 psia Measuring cell with Neobee 00 mbar a/0 kpa a/.45 psia Upper measuring limit 00 % of max. span Input of absolute pressure, with front-flush diaphragm Measured variable Absolute pressure, front-flush Span (continuously adjustable) or measuring range, max. operating pressure and max. test pressure HART PROFIBUS PA/ FOUNATION Fieldbus Span Nominal measuring range mbar a kpa a in O a mbar a kpa a psia bar a MPa a psia 300 mbar a 30 kpa a 55 in O a 5000 mbar a 500 kpa a 7.5 psia 30 bar a 3 MPa a 435 psia Max. operating pressure MAWP (PS) 4bar 400 kpa 58 psi 7bar 0.7 MPa 0 psi bar. MPa 305 psi 67 bar 6.7MPa 97 psi Max. operating pressure MAWP (PS).6 bar a 60 kpa a 37.7 psia 0 bar a MPa a 45 psia 45 bar a 4.5 MPa a 653 psia Max. perm. test pressure 6bar 600 kpa 87 psi) 0 bar MPa 45 psi 3 bar 3. MPa 464 psi 00 bar 0 MPa 450 psi Max. perm. test pressure 0 bar a MPa a 45 psia 30 bar a 3 MPa a 435 psia 00 bar a 0 MPa a 450 psia epending on the process connection, the span may differ from these values Lower measuring limit 0 mbar a/0 kpa a/0 psia Upper measuring limit 00 % of max. span Output HART PROFIBUS PA/FOUNATION Fieldbus Output signal ma igital PROFIBUS PA and FOUNATION Fieldbus signal Lower limit (infinitely adjustable) 3.55 ma, factory preset to 3.84 ma - Upper limit (infinitely adjustable) 3 ma, factory preset to 0.5 ma or - optionally set to.0 ma Load Without HART R B (U H V)/0.03 A in, - U H : Power supply in V With HART R B = (SIMATIC PM) or - R B = (HART Communicator) Physical bus - IEC 658- Protection against polarity reversal Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. Electrical damping (step width 0. s) Set to s ( s) / Siemens FI 0 06 US Edition
2 Siemens AG 06 SITRANS P S III series for gauge and absolute pressure, with front-flush diaphragm Measuring accuracy Acc. to IEC Reference conditions (All error data refer always refer to the set span) SITRANS P S III for gauge/absolute pressure, with front-flush diaphragm Increasing characteristic Start-of-scale value 0 bar/kpa/psi Stainless steel seal diaphragm Silicone oil filling Room temperature 5 C (77 F) Measuring span ratio r (spread, Turn-own) r = max. measuring span/set measuring span or nom. pressure range Error in measurement at limit setting incl. hysteresis and reproducibility Linear characteristic Gauge pressure, front-flush Absolute pressure, front-flush -r % - - 5<r 00 (0.005 r ) % - -r 0-0. % -0<r % Influence of ambient temperature (0.08 r + 0.6) % (0.6 r + 0.4) % (in percent per 8 C (50 F)) Effect of ambient temperature (in pressure per temperature change) Temperature difference between medium 3 mbar/0.3 kpa/0.04 psi per 0 K temperature and ambient temperature Long-term stability (temperature change 30 C ( 54 F)) (0.5. r) % in 5 years Effect of mounting position (in pressure per change in angle) 0.4 mbar/0.04 kpa/0.006 per 0 inclination (zero point correction is possible with position error compensation) Effect of auxiliary power supply % per V (in percent per change in voltage) Measuring value resolution for PROFIBUS PA and of nominal measuring range FOUNATION Fieldbus Rated conditions Installation conditions Ambient temperature Observe the temperature class in areas subject to explosion hazard. Measuring cell with silicone oil C ( F) Measuring cell with Neobee oil (with front-flush diaphragm) C ( F) Measuring cell with inert liquid C ( F) Transmitter (with 4-wire connection, observe temperature values of supplementary 4-wire electronics) C ( F) isplay readable C ( F) Storage temperature C ( F) (in the case of Neobee: C ( / F)) (for high temperature oil: C ( F)) Climatic class Condensation Relative humidity % Condensation permissible, suitable for use in the tropics egree of protection (to IEC 6059) IP66 (optional IP66/IP68), NEMA 4X Electromagnetic Compatibility Emitted interference and interference immunity Acc. to IEC 636 and NAMUR NE Medium conditions The max. medium temperature of the front-flush process connections is to be taken into account in accordance with the relevant connection standards (e. g. IN 3676, IN 85 etc.). Temperature of medium Measuring cell with silicone oil C ( F) Measuring cell with silicone oil (with front-flush diaphragm) C ( F) Measuring cell with Neobee oil (with front-flush diaphragm) C ( F) Measuring cell with silicone oil, with temperature decoupler C ( F) (only for gauge pressure version with front-flush diaphragm) Measuring cell with Neobee oil, with temp. decoupler (only for C ( F) gauge pressure version with flush-mounted diaphragm) Measuring cell with inert filling liquid C ( F) Measuring cell with high-temperature oil (only for gauge pressure version with front-flush C ( F) diaphragm) Siemens FI 0 06 US Edition /3
3 Siemens AG 06 SITRANS P S III for gauge/absolute pressure, with front-flush diaphragm SITRANS P S III series for gauge and absolute pressure, with front-flush diaphragm esign Weight (without options).5 kg ( 3.3 lb) Enclosure material Low-copper die-cast aluminum, G-AlSi or stainless steel precision casting, mat. no Wetted parts materials Stainless steel, mat. no..4404/36l or Hastelloy C76, mat. no..489 Measuring cell filling Silicone oil or inert filling liquid Process connection Flanges as per EN and ASME F&B and pharmaceutical flanges Surface quality touched-by-media R a -values 0.8 µm (3 µ-inch)/welds R a).6 µm (64 µ-inch) (Process connections acc. to 3A; R a -values 0.8 µm (3 µ-inch)/welds R a ) 0.8 µm (3 µ-inch) Power supply U H HART PROFIBUS PA/FOUNATION Fieldbus Terminal voltage on transmitter V C V C in intrinsically-safe mode Power supply - Supplied through bus Separate 4 V power supply necessary - No Bus voltage Not Ex V With intrinsically-safe operation V Current consumption Basic current (max.) -.5 ma Start-up current basic current - Yes Max. current in event of fault ma Fault disconnection electronics (FE) available - Yes /4 Siemens FI 0 06 US Edition
4 Siemens AG 06 SITRANS P S III for gauge/absolute pressure, with front-flush diaphragm SITRANS P S III series for gauge and absolute pressure, with front-flush diaphragm Certificates and approvals Classification according to PE 04/68/EU For gases of fluid group and liquids of fluid group ; complies with requirements of article 4, paragraph 3 (sound engineering practice) Explosion protection Intrinsic safety "i" PTB 3 ATEX 007 X - Marking Ex II / G Ex ia/ib IIC T4/T5/T6 Ga/Gb - Permissible ambient temperature C ( F) temperature class T4; C ( F) temperature class T5; C ( F) temperature class T6 - Connection To certified intrinsically-safe circuits with peak values: U i = 30 V, I i = 00 ma, P i = 750 mw; R i =300 FISCO supply unit: U o = 7.5 V, I o = 380 ma, P o = 5.3 W Linear barrier: U o = 4 V, I o = 50 ma, P o =. W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 H, C i =. nf Explosion-proof "d" PTB 99 ATEX 60 - Marking Ex II / G Ex d IIC T4/T6 Gb - Permissible ambient temperature C ( F) temperature class T4; C ( F) temperature class T6 - Connection To circuits with values: U H = V C To circuits with values: U H = V C ust explosion protection for zone 0 PTB 0 ATEX Marking Ex II Ex ta IIIC T0 C a Ex II / Ex ta/tb IIIC T0 C a/b - Permissible ambient temperature C ( F) - Max. surface temperature 0 C (48 F) - Connection To certified intrinsically-safe circuits with peak values: U i = 30 V, I i = 00 ma, P i = 750 mw, R i = 300 FISCO supply unit: U o = 7.5 V, I o = 380 ma, P o = 5.3 W Linear barrier: U o = 4 V, I o = 50 ma, P o = W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 H, C i =. nf ust explosion protection for zone / Ex II Ex tb IIIC T0 C b - Marking Ex II IP65 T 0 C - Connection To circuits with values: U H = V C; P max =. W Type of protection "n" (zone ) PTB 3 ATEX 007 X - Marking Ex II /3 G Ex na II T4/T5/T6 Gc Ex II /3 G Ex ic IIC T4/T5/T6 Gc - Connection (Ex na) U m = 45 V U m = 3 V - Connections (Ex ic) To circuits with values: U i = 45 V To circuits with values: U H =9...3 V C; P max = W FISCO supply unit ic: U o = 7.5 V, I o = 570 ma Linear barrier: U o = 3 V, I o = 3 ma, P o = W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 H, C i =. nf Explosion protection acc. to FM Certificate of Compliance Identification (XP/IP) or (IS); (NI) CL I, IV, GP ABC T4...T6; CL II, IV, GP EFG; CL III; CL I, ZN 0/ AEx ia IIC T4...T6; CL I, IV, GP ABC T4...T6; CL II, IV, GP FG; CL III Explosion protection to CSA Certificate of Compliance Identification (XP/IP) or (IS) CL I, IV, GP ABC T4...T6; CL II, IV, GP EFG; CL III; Ex ia IIC T4...T6; CL I, IV, GP ABC T4...T6; CL II, IV, GP FG; CL III Hygiene version In the case of SITRANS P SIII with 7MF43x front-flush diaphragm, selected connections comply with the requirements of EHEG. Siemens FI 0 06 US Edition /5
5 Siemens AG 06 SITRANS P S III for gauge/absolute pressure, with front-flush diaphragm HART communication HART Protocol HART Version 5.x Software for computer SIMATIC PM PROFIBUS PA communication Simultaneous communication with 4 master class (max.) The address can be set using Configuration tool or local operation (standard setting address 6) Cyclic data usage Output byte 5 (one measured value) or 0 (two measured values) Input byte 0,, or (register operating mode and reset function for metering) Internal preprocessing evice profile PROFIBUS PA Profile for Process Control evices Version 3.0, class B Function blocks Analog input - Adaptation to customer-specific process variables Yes, linearly rising or falling characteristic - Electrical damping, adjustable s - Simulation function Input /Output - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode parameterizable (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively Physical block Transducer blocks Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Specification of a container Max. 30 nodes characteristic with - Square-rooted characteristic Yes for flow measurement - Gradual volume suppression Parameterizable and implementation point of square-root extraction - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function FOUNATION Fieldbus communication Function blocks 3 function blocks analog input, function block PI Analog input - Adaptation to customer-specific process variables characteristic Yes, linearly rising or falling - Electrical damping, adjustable s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic Yes for flow measurement PI Standard FOUNATION Fieldbus function block Physical block resource block Transducer blocks transducer block Pressure with calibration, transducer block LC Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function /6 Siemens FI 0 06 US Edition
6 Siemens AG 06 Pressure transmitter for gauge and absolute pressure, front-flush diaphragm, SITRANS P S III HART Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Measuring cell cleaning SITRANS P S III for gauge/absolute pressure, with front-flush diaphragm Article No. 7 M F Silicone oil normal Inert liquid grease-free to 3 cleanliness level FA compliant fill fluid Neobee oil normal 4 Measuring span (min.... max.) bar ( psi) B bar ( psi) C bar ( psi) bar ( psi) E mbar a ) ( psia) ) S bar a ) ( psia) ) T bar a ) ( psia) ) U Wetted parts materials Seal diaphragm Connection shank Stainless steel Stainless steel A Hastelloy ) Stainless steel B Process connection Flange version with Order M.., N.., R.. or Q.. 7 Non-wetted parts materials Housing made of die-cast aluminium 0 Housing stainless steel precision casting 3 Version Standard version, German plate inscription, setting for pressure unit: bar International version, English plate inscription, setting for pressure unit: bar Chinese version, English plate inscription, 3 setting for pressure unit: Pascal All versions include V with documentation for SITRANS P in German, English, French, Italian and Spanish. Includes Compact operating instructions in various EU languages. Explosion protection None A With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" B - "Explosion-proof (Ex d)" 3) - Ex na/ic (Zone ) 4) E FM + CSA intrinsic safe (is) 5) F FM + CSA (is + ep) + Ex ia + Ex d (ATEX) + S Zone / 5)6)7) With FM + CSA, Type of protection: - "Intrinsic Safe and Explosion Proof (is + xp)" 3)5) N C Article No. Pressure transmitter for gauge and absolute 7 M F pressure, front-flush diaphragm, SITRANS P S III HART isplay Without display 0 Without visible display (display concealed, setting: ma) With visible display (setting: ma) 6 With customer-specific display 7 (setting as specified, Order "Y" or "Y" required) Power supply units see Chap. 7 "Supplementary Components". Included in delivery of the device: Brief instructions (Leporello) V with detailed documentation ) Not with temperature decoupler P00 and P0, not for process connections R0, R04, R0 and R, and can only be ordered in conjunction with silicone oil. ) Only available for flanges with options M.., N.. and Q.. 3) Without cable gland, with blanking plug 4) Configurations with HAN and M connectors are only available in Ex ic. 5) Explosion protection acc. to FM/CSA: suitable for installations according to NEC 500/505. 6) Only in connection with IP66. 7) With enclosed cable gland Ex ia and blanking plug. 8) Only in connection with Ex approval A, B or E. 9) Only in connection with Ex approval A, B, E or F. 0) M delivered without cable socket Electrical connection/cable entry Inner thread M0 x.5 Female thread ½-4 NPT Han 7 plug (plastic housing) incl. mating connector 8) M connectors (stainless steel) 9) 0) F B C Siemens FI 0 06 US Edition /7
7 Siemens AG 06 Article No. Pressure transmitter P for gauge and absolute pressure, front-flush diaphragm: SITRANS P S III with PROFIBUS PA (PA) 7 M F SITRANS P S III with FOUNATION Fieldbus (FF) 7 M F Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Measuring cell cleaning Silicone oil normal Inert liquid grease-free to 3 cleanliness level FA compliant fill fluid Neobee oil normal 4 Nominal measuring range bar (4.5 psi) B 4 bar (58 psi) C 6 bar (3 psi) 63 bar (94 psi) E 300 mbar a ) (8.85 psia) ) S 5 bar a ) (7.5 psia) ) T 30 bar a ) (435 psia) ) U Wetted parts materials Seal diaphragm Connection shank Stainless steel Stainless steel A Hastelloy ) Stainless steel B Process connection Flange version with Order M.., N.., R.. or 7 Q.. Non-wetted parts materials Housing made of die-cast aluminium 0 Housing stainless steel precision casting 3 Version Standard version, German plate inscription, setting for pressure unit: bar International version, English plate inscription, setting for pressure unit: bar Chinese version, English plate inscription, 3 setting for pressure unit: Pascal All versions include V with documentation for SITRANS P in German, English, French, Italian and Spanish. Includes Compact operating instructions in various EU languages. Explosion protection None A With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" B - "Explosion-proof (Ex d)" 3) - Ex na/ic (Zone ) 4) E FM + CSA intrinsic safe (is) 5) F FM + CSA (is + ep) + Ex ia + Ex d (ATEX) + S Zone / 5)6)7) With FM + CSA, Type of protection: - "Intrinsic Safe and Explosion Proof (is + xp)" 3)5) (available soon) N C Electrical connection/cable entry Screwed gland M0 x.5 B Screwed gland ½-4 NPT C M connectors (stainless steel) 8) 9) F Article No. Pressure transmitter P for gauge and absolute pressure, front-flush diaphragm: SITRANS P S III with PROFIBUS PA (PA) 7 M F SITRANS P S III with FOUNATION Fieldbus (FF) 7 M F isplay Without display 0 Without visible display (display concealed, setting: bar) With visible display (setting: bar) 6 With customer-specific display (setting 7 as specified, Order "Y" required) Included in delivery of the device: Brief instructions (Leporello) V with detailed documentation ) Not with temperature decoupler P00 and P0, not for process connections R0, R0, R04, R0 and R, and can only be ordered in conjunction with silicone oil. ) Only available for flanges with options M.., N.. and Q. 3) Without cable gland, with blanking plug 4) Configurations with HAN and M connectors are only available in Ex ic. 5) Explosion protection acc. to FM/CSA: suitable for installations according to NEC 500/505. 6) Only in connection with IP66. 7) With enclosed cable gland Ex ia and blanking plug. 8) Only in connection with Ex approval A, B, E or F. 9) M delivered without cable socket SITRANS P S III for gauge/absolute pressure, with front-flush diaphragm /8 Siemens FI 0 06 US Edition
8 Siemens AG 06 Further designs Add "-Z" to Article No. and specify Order. Order Plug Han 7 (metal) A30 Han 8 (instead of Han 7) A3 Angled A3 Han 8 (metal) A33 SITRANS P S III for gauge/absolute pressure, with front-flush diaphragm HART PA FF Cable sockets for M connectors A50 (metal (CuZn)) Rating plate inscription (instead of German) English B French B Spanish B3 Italian B4 Cyrillic (russian) B6 English rating plate B Pressure units in in 0 and/or psi Quality Inspection Certificate (5-point characteristic C curve test) according to IEC Inspection certificate C Acc. to EN Factory certificate C4 Acc. to EN Functional safety (SIL) C0 evices suitable for use according to IEC 6508 and IEC 65. Includes SIL conformity declaration Functional safety (PROFIsafe) Certificate and PROFIsafe protocol C ) Functional safety (SIL/3) C3 evices suitable for use according to IEC 6508 and IEC 65. Includes SIL conformity declaration evice passport Russia C99 Setting of upper limit of output signal to 05.0 ma egree of protection IP66/IP68 (only for M0x.5 and ½-4 NPT) Capri cable gland 4F CrNi and clamping 59 device ( ) included Oxygen application E0 (In the case of oxygen measurement and inert liquid max. 00 bar (450 psi) at 60 C (40 F)) Export approval Korea E CRN approval Canada E (Canadian Registration Number) ual seal E4 Explosion-proof "Intrinsic safety" (Ex ia) to E5 ) INMETRO (Brazil) (only for transmitter 7MF B..) "Flameproof" explosion protection according E6 ) to INMETRO (Brazil) (only for transmitter 7MF ) Explosion-proof "Intrinsic safety" (Ex ia + E8 ) Ex d) to INMETRO (Brazil) (only for transmitter 7MF P..) Ex Approval IEC Ex (Ex ia) E45 ) (only for transmitter 7MF B..) Ex Approval IEC Ex (Ex d) E46 ) (only for transmitter 7MF ) Order Further designs Add "-Z" to Article No. and specify Order. HART PA FF Explosion-proof "Intrinsic safety" to NEPSI E55 ) (China) (only for transmitter 7MF B..) Explosion protection "Explosion-proof" to E56 ) NEPSI (China) (only for transmitter 7MF ) Ex protection "Zone " to NEPSI (China) E57 ) (only for transmitter 7MF E..) Ex protection Ex ia, Ex d and Zone E58 ) to NEPSI (China) (only for transmitter 7MF R..) "Intrinsic safety" and "Explosion-proof" E70 ) explosion protection acc. to Kosha (Korea) (only for transmitter 7MF [B, ]..-Z + E) Ex-protection Ex ia according to EAC Ex E80 3) (Russia) Ex-protection Ex d according to EAC Ex (Russia) E8 3) Ex-protection Ex na/ic (Zone ) according to E8 3) EAC Ex (Russia) Ex-protection Ex ia + Ex d + Zone / E83 3) according to EAC Ex (Russia) Two coats of lacquer on casing and cover G0 (PU on epoxy) Transient protector 6 kv (lightning protection) J0 Flanges to EN 09-, Form B N 5, PN 40 4) M N 40, PN 40 M3 N 40, PN 00 M3 N 50, PN 6 M04 N 50, PN 40 M4 N 80, PN 6 M06 N 80, PN 40 M6 Flanges to ASME B6.5 Stainless steel flange " class 50 4) M40 Stainless steel flange ½" class 50 M4 Stainless steel flange " class 50 M4 Stainless steel flange 3" class 50 M43 Stainless steel flange 4" class 50 M44 Stainless steel flange ½" class 300 M46 Stainless steel flange " class 300 M47 Stainless steel flange 3" class 300 M48 Stainless steel flange 4" class 300 M49 Threaded connector to IN 385-, form A, thread to ISO 8 G ¾"-A, front-flush 5) R0 G "-A, front-flush 5) R0 G "-A, front-flush R04 Tank connection 6) Sealing is included in delivery TG 5/50, PN 40 R0 TG 5/50, PN 40 R Siemens FI 0 06 US Edition /9
9 Siemens AG 06 SITRANS P S III for gauge/absolute pressure, with front-flush diaphragm Order Further designs HART PA FF Add "-Z" to Article No. and specify Order. Sanitary process connection according IN 85 (airy connection with slotted union nut) N 50, PN 5 N04 N 80, PN 5 N06 Tri-Clamp connection according IN 3676/ISO 85 N 50/", PN 6 N4 N 65/3", PN 0 N5 Varivent connection EHEG compliant Type N = 68 for Varivent housing N8 N and ½"... 6", PN 40 Temperature decoupler up to 00 C 7) P00 for version with front-flush diaphragm Temperature decoupler up to 50 C P0 Measuring cell filling: High-temperature oil, only in conjunction with measuring cell filling silicone oil Sanitary process connection to R N 50, PN 40 M3 SMS socket with union nut M67 ½ M68 3 M69 SMS threaded socket M73 ½ M74 3 M75 IF socket with union nut ISO 853 M8 ½ M83 3 M84 IF threaded socket ISO 853 M9 ½ M93 3 M94 Sanitary process connection to NEUMO Bio-Connect screw connection EHEG compliant N 50, PN 6 Q05 N 65, PN 6 Q06 N 80, PN 6 Q07 N 00, PN 6 Q08 N ", PN 6 Q3 N ½", PN 6 Q4 N 3", PN 6 Q5 N 4", PN 6 Q6 Sanitary process connection to NEUMO Bio-Connect flange connection EHEG compliant N 50, PN 6 Q3 N 65, PN 6 Q4 N 80, PN 6 Q5 N 00, PN 6 Q6 N ", PN 6 Q3 N ½", PN 6 Q3 N 3", PN 6 Q33 N 4", PN 6 Q34 Order Further designs HART PA FF Add "-Z" to Article No. and specify Order. Sanitary process connection to NEUMO Bio-Connect clamp connection EHEG compliant N 50, PN 6 Q39 N 65, PN 0 Q40 N 80, PN 0 Q4 N 00, PN 0 Q4 N ½", PN 6 Q48 N 3", PN 0 Q49 N 4", PN 0 Q50 Bio-Control sanitary process connection EHEG compliant 8) N 50, PN 6 Q53 N 65, PN 6 Q54 Sanitary process connection to NEUMO Bio-Connect S flange connection EHEG compliant N ", PN 6 Q7 Aseptic threaded socket to IN 864- Form A EHEG compliant N 50, PN 5 N33 N 65, PN 5 N34 N 80, PN 5 N35 N 00, PN 5 N36 Aseptic flange with notch to IN 864- Form A EHEG compliant N 50, PN 6 N43 N 65, PN 6 N44 N 80, PN 6 N45 N 00, PN 6 N46 Aseptic flange with groove to IN 864- Form A EHEG compliant N 50, PN 6 N43 + P N 65, PN 6 N44 + P N 80, PN 6 N45 + P N 00, PN 6 N46 + P Aseptic clamp with groove to IN FormA EHEG compliant N 50, PN 5 N53 N 65, PN 5 N54 N 80, PN 6 N55 N 00, PN 6 N56 ) Profisafe transmitters can only be operated with the S7 F Systems V6. configuration software in combination with S7-400H. ) Option does not include ATEX approval, but instead includes only the country-specific approval. 3) Approval pending. 4) Special seal in Viton included in the scope of delivery. FKM; temperature range C ( C) 5) Cannot be combined with Order s P00 and P0. Can only be ordered with silicone oil measuring cell filling. 6) The weldable socket can be ordered under accessories. 7) 3A and EHEG compliant. The maximum permissible temperatures of the medium depend on the respective cell fillings (see medium conditions). 8) 3A compliance ensured only when 3A compliant sealing rings are used. /30 Siemens FI 0 06 US Edition
10 Siemens AG 06 Order Additional data HART PA FF Please add "-Z" to Article No. and specify Order (s) and plain text. Measuring range to be set Y0 ) Specify in plain text (max. 5 characters): Y0:... up to... mbar, bar, kpa, MPa, psi Stainless steel tag plate and entry in Y5 device variable (measuring point description) Max. 6 characters, specify in plain text: Y5:... Measuring point text (entry in device variable) Y6 Max. 7 characters, specify in plain text: Y6:... Entry of HART address (TAG) Y7 Max. 8 characters, specify in plain text: Y7:... Setting of pressure indicator in pressure Y units Specify in plain text (standard setting: bar): Y: mbar, bar, kpa, MPa, psi,... Note: The following pressure units can be selected: bar, mbar, mm O *), in O *), ft O *), mmhg, inhg, psi, Pa, kpa, MPa, g/cm, kg/cm, Torr, ATM or % *) ref. temperature 0 C SITRANS P S III for gauge/absolute pressure, with front-flush diaphragm Setting of pressure indication in non-pressure units ) Specify in plain text: Y:... up to... l/min, m 3 /h, m, USgpm,... (specification of measuring range in pressure units "Y0" is essential, unit with max. 5 characters) Y + Y0 Preset bus address Y5 possible between and 6 Specify in plain text: Y5:... amping adjustment in seconds ( s) Y30 Only Y0, Y5, Y6, Y7, Y, Y, Y5 and 05 can be factory preset = available ordering example Item line: 7MF433-B0-AB7-Z B line: A + Y0 + Y C line: Y0:... 0 bar ( psi) C line: Y: bar (psi) ) Measuring accuracies for PROFIBUS PA transmitters with Option Y0 are calculated in the same way as for HART devices. ) Preset values can only be changed over SIMATIC PM. Siemens FI 0 06 US Edition /3
11 Siemens AG 06 SITRANS P S III for gauge/absolute pressure, with front-flush diaphragm imensional drawings 5 (0.6) 43 (5.6) 74 (.9) 53 (.) 5 (0.6) 4 (0.94) 9 (.4) 84 (3.3) 4 50 (.97) Ø80 (3.5) 7 Space for rotation of housing 50 (.97) (5.) H = approx. H = approx. 55 (.7) Temperature decoupler min. 90 (3.54) ) 3 Electronic side, digital display (longer overall length for cover with window) ) Terminal side ) Electrical connection: Screwed gland M0 x,5 or screwed gland ½-4 NPT or M conector Protective cover over keys Blanking plug Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) Process connection: see flange tables ) ) Allow approx. 0 mm (0.79 inch) thread length to permit unscrewing 9 mm (3.6 inch) for minimum distance to permit rotation with indicator SITRANS P pressure transmitters, S III series for gauge pressure, with front-flush diaphragm, dimensions in mm (inch) The diagram shows a SITRANS P S III with an example of a flange. In this drawing the height is subdivided into H and. H = Height of the SITRANS P300 up to a defined cross-section = Height of the flange up to this defined cross-section Only the height is indicated in the dimensions of the flanges. /3 Siemens FI 0 06 US Edition
12 Siemens AG 06 SITRANS P S III for gauge/absolute pressure, with front-flush diaphragm Flanges as per EN and ASME Sanitary process screw connection to NEUMO Bio-Connect Flange to EN Order N PN EN 09- Order N PN H Q mm (3. ) Approx. Q mm (4. ) 5 mm ( ) M mm (4.5 ) Approx. Q mm (4.5 ) M mm (5.9 ) 5 mm ( ) Q mm (5.7 ) Q3 6 8 mm (3. ) M mm (6.7 ) Q4 ½ 6 05 mm (4. ) M mm (6.5 ) Q mm (4. ) M mm (6.5 ) Q mm (5.7 ) M mm (7.9 ) M mm (7.9 ) Sanitary process connection to NEUMO Bio-Connect flange Flanges to ASME connection ASME B6.5 Order N PN Order N PN Q mm (4.3 ) Approx. Q mm (5.5 ) 5 mm ( ) M mm (4.3 ) Approx. Q mm (5.9 ) M4 ½ mm (5. ) 5 mm ( ) Q mm (6.9 ) M mm (5.9 ) Q mm (3.9 ) M mm (7.5 ) Q3 ½ 6 0 mm (4.3 ) M mm (9. ) Q mm (5.5 ) M46 ½ mm (6. ) Q mm (6.9 ) M mm (6.5 ) M mm (8. ) Sanitary process connection to NEUMO Bio-Connect clamp M mm (0.0 ) connection NuG and pharmaceutical connections Order N PN Connections to IN IN 85 (milk pipe union with slotted union nut) Order N PN N mm (3.6 ) Approx. N mm (5.0 ) 5 mm ( ) Tri-Clamp nach IN 3676 Order N PN N mm (.5 ) Approx. N mm (3.6 ) 5 mm ( ) Q mm (3.0 ) Approx. Q mm (3.6 ) 5 mm ( ) Q mm (4. ) Q mm (4.7 ) Q48 ½ mm (3.6 ) Q mm (4. ) Q mm (4.7 ) Sanitary process connection to NEUMO Bio-Connect S flange connection Order N PN Q7 6 5 mm (4.9 ) Approx. 5 mm ( ) Other connections Varivent connection Order N PN N mm Approx. (3.3 ) 5 mm ( ) Sanitary process connection to R Order N PN M mm (4. ) Approx. 5 mm ( ) Threaded connection G¾", G" and G" acc. to IN 385 Order N PN R0 ¾ mm (.5 ) Approx. 45 mm (.8 ) R mm (.9 ) Approx. 47 mm (.9 ) R mm (3. ) Approx. 5 mm ( ) Siemens FI 0 06 US Edition /33
13 Siemens AG 06 SITRANS P S III for gauge/absolute pressure, with front-flush diaphragm Tank connection TG 5/50 and TG5/50 Order N PN R mm (.5 ) Approx. 63 mm (.5 ) R mm (.5 ) Approx. 70 mm (6.7 ) Aseptic threaded socket to IN 864- Form A Order N PN N x /6 Approx. N x /6 5 mm ( ) N x ¼ N x ¼ SMS socket with union nut Order N PN M mm (3.3 ) Approx. M68 ½ 5 00 mm (3.9 ) 5 mm ( ) M mm (4.5 ) SMS threaded socket Order N PN M x /6 mm Approx. M74 ½ 5 85 x /6 mm 5 mm ( ) M x /6 mm IF socket with union nut Order N PN M mm (3 ) Approx. M83 ½ 5 9 mm (3.6 ) 5 mm ( ) M mm (4. ) IF threaded socket Order N PN M mm (.5 ) Approx. M93 ½ mm (3. ) 5 mm ( ) M mm (3.6 ) Aseptic flange with notch to IN 864- Form A Order N PN N Approx. N mm ( ) N N Aseptic flange with groove to IN 864- Form A Order N PN N Approx. P 5 mm ( ) N P N P N P Aseptic clamp with groove to IN Form A Order N PN N Approx. N mm ( ) N N /34 Siemens FI 0 06 US Edition
Siemens AG Span (min... max.) Max. perm. test. 87 psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar)
SITRANS P S III for gauge/absolute pressure, Technical specifications SITRANS P S III series for gauge and absolute pressure, HART PROFIBUS PA and FOUNATION Fieldbus Input of gauge pressure, Measured variable
More informationPressure Measurement Transmitters for applications with advanced requirements (Advanced)
Siemens AG 206 Technical specifications SITRANS P DS III series for absolute pressure (from the gauge pressure series) Input Measured variable Absolute pressure Span (fully adjustable) or measuring range,
More informationSiemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar)
Technical specifications SITRANS P, DS III series Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure HART Gauge pressure Span (min.... max.)
More information1 Technical specifications
Siemens AG 07 Technical specifications SITRANS P, DS III series for gauge pressure Input Measured variable Gauge pressure Span (fully adjustable) or measuring range, max. operating HART pressure (in accordance
More informationPressure Measurement Transmitters for applications with advanced requirements (Advanced)
Siemens AG 207 Technical specifications SITRANS P DS III series for absolute pressure (from the gauge pressure series) Input Measured variable Absolute pressure Span (fully adjustable) or measuring range,
More informationPressure Measurement Transmitters for applications with advanced requirements (Advanced)
Siemens AG 06 Technical specifications SITRANS P, DS III for differential pressure and flow Input Measured variable Differential pressure and flow Span (fully adjustable) or measuring range, max. operating
More information1 Technical specifications
Siemens AG 07 Technical specifications SITRANS P, DS III for differential pressure and flow Input Measured variable Differential pressure and flow Span (fully adjustable) or measuring range, max. operating
More informationPressure Measurement Single-range transmitters for general applications
Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials
More informationPressure Measurement Transmitters for food, pharmaceuticals and biotechnology
Siemens AG 206 Overview The SITRANS P300 is a digital pressure transmitter for relative and absolute pressure. The conventional thread versions are available as process connections, as are flush-mounted
More information1 Overview. Pressure Measurement Transmitters for food, pharmaceuticals and biotechnology. SITRANS P300 for gauge and absolute pressure
Siemens AG 208 Overview The SITRANS P300 is a digital pressure transmitter for relative and absolute pressure. The conventional thread versions are available as process connections, as are flush-mounted
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More information1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure
Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3
More informationPressure Measurement. Transmitters for food, pharmaceuticals and biotechnology. SITRANS P300 for gauge and absolute pressure. 2/34 Siemens FI
Overview The SITRANS P300 is a digital pressure transmitter for relative and absolute pressure All conventional thread versions are available as process connections. In addition, various hygienebased connections
More information2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure
Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More information1 Overview. Pressure Measurement Transmitters for general requirements. SITRANS P DS III - Technical description
Siemens AG 204 SITRANS P DS III - Technical description Overview SITRANS P DS III pressure transmitters are digital pressure transmitters featuring extensive user-friendliness and high accuracy. The parameterization
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationPressure Measurement. Transmitters for general requirements SITRANS P DS III Technical description. 2/74 Siemens FI
Technical description Overview Siemens AG 010 pressure transmitters are digital pressure transmitters featuring extensive user-friendliness and high accuracy. The parameterization is performed using control
More informationPressure Measurement Transmitters for applications with advanced requirements (Advanced)
Overview SITRANS P DS III - Technical description SITRANS P DS III pressure transmitters are digital pressure transmitters featuring extensive user-friendliness and high accuracy. The parameterization
More informationTYPE APPROVAL CERTIFICATE
TYPE APPROVAL CERTIFICATE Certificate No: TAA0000123 This is to certify: That the Pressure Transmitter with type designation(s) SITRANS P series DS III, P310, P410 Issued to Siemens AG - Process Industries
More informationPressure Measurement Transmitters for applications with advanced requirements (Advanced)
Siemens AG 07 Overview SITRANS P DS III - Technical description SITRANS P DS III pressure transmitters are digital pressure transmitters featuring extensive user-friendliness and high accuracy. The parameterization
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition
Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationPressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview
f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI
Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationSITRANS P measuring instruments for pressure
Siemens AG 009 SITRANS P measuring instruments for pressure Overview The SITRANS P300 is a digital pressure transmitter for gauge and absolute pressure. All conventional thread versions are available as
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure
More informationDMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.
Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:
More informationTechnical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications
Technical Datasheet D Series SMART Pressure Transmitter Model: DPC-2000 Key Features ATEX - Flameproof and Intrinsically Safe IECEx - Flameproof and Intrinsically Safe SIL 2 certificate Compliant to NAMUR
More informationx act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor
Precision- Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output
More informationx act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.
Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output
More informationPressure transmitter PASCAL Ci4
Pressure transmitter PASCAL Ci4 for general application,type Series CI4100 Features Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids High-resolution
More informationSITRANS P measuring instruments for pressure
Siemens AG 007 SITRANS P measuring instruments for pressure / Product overview /4 Transmitters for gage and absolute pressure /4 Z series for gage and absolute pressure /9 ZD series for gage and absolute
More informationElectropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765
Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Application Single-acting positioner for attachment to pneumatic control valves. Supplied with either an electric input signal from
More informationOPTIBAR P 1010 C Technical Datasheet
Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability
More informationIDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger
More informationDM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More information2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor
INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters Features Include Base accuracy : ±0.075% Span limits
More informationETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More information2600T Series Pressure Transmitter
Data Sheet 2600T Series Pressure Transmitter Model 261GC/GG/GJ/GM/GN Gauge Model 261AC/AG/AJ/AM/AN Absolute with direct mount seal Base accuracy: ±0.15 % Span limits 0.3 to 60000kPa; 1.2inH 2 O to 8700psi
More informationDM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
More informationBourdon tube pressure gauge for diaphragm seals
Bourdon tube pressure gauge for diaphragm seals and switch function, Type series BR42.. Features Bourdon tube pressure gauge for diaphragm seal and switch function Nominal range -1 3 bar to -1 15 bar,
More informationType N-10, N-11 Hazardous Area Non-incendive Transmitters
Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial
More informationCompact differential pressure switch Flameproof enclosure Ex d Models DE, DEC
Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring
More informationATM.1ST/Ex - High Precision Transmitter
Pressure Transmitter - ATEX / IECEx certified ATM.1ST/Ex - High Precision Transmitter CUSTOMER BENEFITS Certificate: ATEX, IECEx & EAC High measurement accuracy is ensured by sophisticated digital temperature
More informationLMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.
LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...
More informationSITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.
Introduction 1 Safety instructions 2 SITRANS Pressure transmitter SITRANS P, Z series for gauge and absolute pressure 7MF1564 Description 3 Assembly and connection 4 Technical data 5 Dimensional drawings
More informationTechnical Data. Dimensions
00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationsitrans p Operating Instructions (de/en) Edition 03/2004
(de/en) Edition 03/2004 sitrans p Messumformer für Food, Pharma und Biotechnik Transmitters for food, pharmaceuticals and biotechnologgy 7FM8010 Contents Information for the operator...27 Important security
More informationRTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features
GE Measurement & Control RTX 1000H Series Versatile Transmitters for a World of Pressure GE Measurement & Control is renowned for the design and manufacture of compact and rugged high performance pressure
More informationATM.ECO/IS - Analog Transmitter with Temperature compensation
Pressure Transmitter - FM / FM-C certified ATM.ECO/IS - Analog Transmitter with Temperature compensation CUSTOMER BENEFITS Certificate: FM, FM-C & IECEx & ATEX Entry level series into precision pressure
More informationED 701 Hygenic Pressure Transmitter
ED 701 Hygenic Pressure Transmitter Hygienic process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response time < 25 ms (Option
More informationTorque Tube TB300 Digital Transmitters
Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional
More informationPrecision pressure sensor Basic version Model CPT6020
Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications
More informationSeries INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN
INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries Series 2000 ALL STAINLESS DESIGN EASY CALIBRATION WITHOUT TEST PRESSURE BY 3 PUSH BUTTONS ACCURACY 0,1% 4-20 ma AND HART PROTOCOL ATEX II
More information1 Overview. Pressure Measurement Remote seals for transmitters and pressure gauges SITRANS P320/P420. 1/352 Siemens FI US Edition
Siemens AG 08 Technical description Overview In many cases the pressure transmitter and the measured medium have to be physically separated. It is then necessary to use a remote seal. The remote seals
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20
More informationA Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >
A Higher Level of Performance Data Sheet Pressure and Level Transmitters For more information, please visit > www.hawkmeasure.com Description Intelligent pressure and level transmitters for all industries
More informationHydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN
Hydrostatic Continuous level measurement 8 Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 187 Hydrostatic Level and pressure measurement Measuring principle The pressure
More informationATM/Ex - Analog Pressure Transmitter
Pressure Transmitter - ATEX certified ATM/Ex - Analog Pressure Transmitter CUSTOMER BENEFITS Certificate: ATEX & EAC Fast customization thanks to configurable product design Demountable electrical connector
More informationTechnical Data. Dimensions
00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable
More informationModel 261GR for gauge pressure Model 261AR for absolute pressure
Change from one to two columns Data Sheet SS/261GR/AR-EN Rev. 07 Model 261GR for gauge pressure Model 261AR for absolute pressure 2600T series pressu re transmitters Engineered solutions for all applications
More informationDifferential pressure
Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor
More informationTechnical Data. Dimensions
0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output
More informationFlow Measurement SITRANS F X
Overview Using a vortex flowmeter with integrated pressure and temperature compensation such as the allows you not only to lower installation costs but also increase the measuring accuracy of the measuring
More informationUltrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63
Ultrasonic 58 Overview VEGASON 60 VEGASON 61, 62, 63 57 Overview VEGASON Area of application The ultrasonic sensors of the VEGASON series are suitable for non-contact level measurement of liquids and bulk
More informationSales presentation. SITRANS P portfolio extension P310 P DS III P410
Sales presentation SITRANS P portfolio extension P310 P DS III P410 Unrestricted / Siemens 2016 All Rights Reserved. usa.siemens.com/pressure SITRANS P The extended pressure family Page 2 Click here to
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 2 mm
0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching
More informationPrecision digital pressure gauge Model CPG1000
Calibration technology Precision digital pressure gauge Model CPG1000 WIKA data sheet CT 10.01 Applications Oil and gas industry Maintenance and service facilities Calibration service companies and service
More information9700 Transmitter Submersible hydrostatic level transmitter
Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous
More informationFlow Measurement SITRANS F C
Overview High-pressure program as standard The sensor calibration factor is also valid for gas measurement. SITRANS FC00 is a compact Coriolis mass sensor suitable for flow measurement of a variety of
More informationJUMO dtrans p30 Pressure Transmitter
609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
More informationSiemens AG Transmitters with WirelessHART 1/42 SITRANS P280 for gauge and abs. pressure. Transmitters for food, pharmaceuticals
Siemens AG 07 / Product overview Single-range transmitters for general applications /5 SITRANS P00 for gauge and abs. pressure / SITRANS P0 for gauge pressure /6 SITRANS P0 for gauge pressure Transmitter
More informationPressure switch with bourdon tube
Pressure switch with bourdon tube for plants requiring special supervision,type series BN4 Features Pressure switch with bourdon tube for plants requiring special supervision, Nominal ranges -1...0 bar
More informationSITRANS P measuring instruments for pressure
Remote seals for transmitters and pressure gauges Technical description Overview In many cases the pressure transmitter and the measured medium have to be physically separated. It is then necessary to
More informationSeries INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN
INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries Series 2000 ALL STAINLESS DESIGN EASY CALIBRATION WITHOUT TEST PRESSURE BY 3 PUSH BUTTONS ACCURACY 0,1% 4-20 ma AND HART PROTOCOL ATEX II
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationMulti Vision. Digital Transmitter 10/ EN
Multi Vision Digital Transmitter 2010TD for Differential Pressure, Flow Rate and Level Spans: 50 Pa... 10 MPa (0.2 in. H 2 O...1500 psi) 2 kpa... 2 MPa abs. (8 in. H 2 O... 300 psia) 2010TDSW.TIF Measured
More informationHow to specify a product. Process Sensors and Mechanical Instruments
How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification
More informationATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified
Intrinsically safe pressure transmitters ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified CUSTOMER BENEFITS Certificate: ATEX & IECEx Fast customization thanks to configurable
More informationATM - Analog Pressure Transmitter
Pressure Transmitter ATM - Analog Pressure Transmitter CUSTOMER BENEFITS Fast customization thanks to configurable product design Demountable electrical connector option to allow adjustment of zero and
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable
More informationUser s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E
User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] 12th Edition 1 1. Introduction Thank you for purchasing the DPharp electronic pressure transmitter. This manual
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationModel 266HSH Gauge Model 266NSH Absolute. 2600T Series Pressure Transmitters Engineered solutions for all applications
Data Sheet DS/266HSH/NSH-EN Rev.C Model 266HSH Gauge Model 266NSH Absolute 2600T Series Pressure Transmitters Engineered solutions for all applications Base accuracy from 0.06 % of calibrated span (optional
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationHigh-speed pressure sensor Model CPT6140
Calibration technology High-speed pressure sensor Model CPT6140 WIKA data sheet CT 25.11 Applications Testing technology Calibration technology Laboratories and maintenance shops Leak and burst applications
More informationUNIK 5600/5700 Marine Certified Pressure Sensing Platform
GE Measurement & Control UNIK 5600/5700 Marine Certified Pressure Sensing Platform The new UNIK 5600/5700 carries marine certification for most zones on-board ship, as well as Intrinsically Safe certifications.
More informationDimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm
Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting
More informationOSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide
OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature
More informationHand-held pressure calibrator with integrated pump Model CPH6600
Calibration technology Hand-held pressure calibrator with integrated pump Model CPH6600 WIKA data sheet CT 16.01 Applications Calibration service companies and service industry Measurement and control
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationDifferential Pressure Transmiter
Differential Pressure Transmiter Description The is an economical alternative to established differential pressure transmitters. It combines state of the art electronics and a high performance sensor;
More informationC-Flow Coriolis Mass Flow Meters
Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM
More informationL (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:
Smart level probe type APC-2000ALW/L Programmable zero shift, range and damping ratio 4...20 ma output signal + HART protocol Accuracy 0,16% Local display Intrinsic safety certificate (ATEX, IECEx) II
More informationProgrammable pressure and temperature transmitters PTM/RS485
Programmable pressure and temperature transmitters PTM/RS485 Version: 03-28-2012 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x
More informationSafety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85
XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions
More information