EZ-CAL HIGH PRESSURE CUT-OUT TEST BLOCK & CALIBRATION KIT

Size: px
Start display at page:

Download "EZ-CAL HIGH PRESSURE CUT-OUT TEST BLOCK & CALIBRATION KIT"

Transcription

1 Form IO (FEB 2018) INSTALLATION - OPERATION File: SERVICE MANUAL - Section 160 Replaces: NOTHING Dist: 3, 3a, 3b, 3c Revised: EZ-CAL HIGH PRESSURE CUT-OUT TEST BLOCK & CALIBRATION KIT THIS MANUAL CONTAINS RIGGING, ASSEMBLY, START-UP, AND MAINTENANCE INSTRUCTIONS. READ THOROUGHLY BEFORE BEGINNING INSTALLATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY OR DEATH, DAMAGE TO THE UNIT, OR IMPROPER OPERATION. Please check for the latest version of this publication.

2 IO (FEB 2018) Page 2 EZ-CAL INSTALLATION - OPERATION Contents GENERAL INFORMATION Preface... 3 Design Limitations... 3 Unit Inspection... 3 Transit Damage Claims... 3 Kit Maintenance... 3 INSTALLATION Retrofit Installation... 4 OPERATION Operation Instructions & Testing... 5 Principals of Operation... 5 Operation Procedure Example... 6 SAFETY PRECAUTION DEFINITIONS DANGER WARNING CAUTION NOTICE Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation or practice which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation or practice which, if not avoided, will result in damage to equipment and/or minor injury. Indicates an operating procedure, practice, etc., or portion thereof which is essential to highlight.

3 EZ-CAL INSTALLATION - OPERATION IO (FEB 2018) Page 3 PREFACE This manual has been prepared to acquaint the owner and serviceman with the INSTALLATION and OPERATION procedures as recommended by Frick Industrial Refrigeration for the EZ-CAL High Pressure Cut-out Test Block and Calibration Kit. Both ASHRAE 15 and IIAR-2 safety standards prohibit the use of an intervening stop valve in the compressor discharge line leading to the high-pressure-limiting device (High Pressure Cut-out, or HPCO). The IIAR-6 standard will require testing of the HPCO yearly to show the function of the device to shut down an operating compressor. The standard does not allow removal and bench testing of the HPCO or testing on a shutdown compressor. There is a safe, simple calibration solution that complies with safety standards. The Frick EZ-CAL test block is designed to be installed between the compressor discharge connection and the HPCO. The unit provides a simple calibration method in compliance with safety standards, while reducing the risk of prematurely lifting a safety relief valve with a resultant ammonia release. It is most important that these units be properly applied to an adequately controlled refrigeration system. Your authori zed Frick representative should be con sulted for their expert guidance in this determination. Proper performance and continued satisfaction with these units is dependent upon: CORRECT INSTALLATION PROPER OPERATION REGULAR, SYSTEMATIC MAINTENANCE To ensure correct installation and application, the HPCO unit should be connected to a properly designed and installed system. General Information NOTICE Trained personnel are required for handling and installation. DESIGN LIMITATIONS The compressor units are designed for operation within the pressure and temperature limits as shown in Frick publication SED. UNIT INSPECTION Immediately upon delivery examine the box and components for dam age. Unpack all items and check against shipping lists for any discrepancy. Examine all items for damage in transit. TRANSIT DAMAGE CLAIMS All claims must be made by consignee. This is an ICC requirement. Request immediate inspection by the agent of the carrier and be sure the proper claim forms are execut ed. Report damage or shortage claims im mediately to Johnson Controls, Frick Sales Ad ministration Depart ment, in Waynesboro, PA. KIT MAINTENANCE If, in the course of regular use, any component in the EZ-CAL block or calibration kit fails to work or any component becomes damaged, the damaged component should be discarded and replaced with a new one.

4 IO (FEB 2018) Page 4 EZ-CAL INSTALLATION - OPERATION This page intentionally left blank.

5 EZ-CAL INSTALLATION IO (FEB 2018) Page 5 Installation RETROFIT INSTALLATION During installation of the test block, care should be taken to minimize total system volume from the test block to the HPCO. Directly installing the HPCO discharge pressure transducer on the test block will keep the volume low, and be much easier to pressurize during testing. WARNING This section must be read and un der stood before installing or performing any main tenance or service to the unit. When installing or performing service you must take several precau tions to ensure your safety: WARNING 1. If unit is running, press [stop] key. 2. Disconnect power from unit before performing any maintenance. 3. Wear proper safety equipment when compressor unit is opened to atmosphere. 4. Ensure adequate ventilation. 5. Take necessary safety precautions required for the refrigerant being used. WARNING Close all compressor package isolation valves prior to servicing the unit. Failure to do so may result in serious injury. SUCTION HIGH PRESSURE CUT-OUT CALIBRATION DIAGRAM COMPRESSOR MOTOR DISCHARGE DISCH PRESSURE HPCO CALIBRATION BLOCK R PE DISCHARGE PRESSURE & HPCO TRANSDUCER TEST PORT CONNECTION PERMANENTLY INSTALLED LOCKABLE '2' POSITION VALVE (RUN/CALIBRATE) C CONNECTION HOSE TO TEST PORT TEMPORARILY INSTALLED FOR FIELD CALIBRATION PI MASTER GAUGE RUN POSITION HAND OIL PUMP CALIBRATE POSITION REFRIGERATION OIL SUMP

6 IO (FEB 2018) Page 6 EZ-CAL INSTALLATION - OPERATION This page intentionally left blank.

7 EZ-CAL OPERATION IO (FEB 2018) Page 7 Operation OPERATION INSTRUCTIONS & TESTING The Frick EZ-CAL test block, 720B0129H01, is designed to be installed between the compressor discharge connection and the discharge pressure limiting device, (the high pressure cut-out, or HPCO). Figure 1. Test Block in Test & Run Position will open and expose the HPCO to the high pressure level, still allowing protection of the compressor during testing of the HPCO. One EZ-CAL test block should be installed permanently on each compressor and only be used when the HPCO is to be tested. They can be locked in the RUN position during normal operation, but the compressor is still protected from a high pressure event in either operational position. NOTICE Leaving the test block valve in the TEST position after testing is complete can trap the external pressure between the HPCO and the test port. The only risk by leaving the test block valve in the TEST position after testing is complete is trapping the external pressure between the HPCO and the test port. The discharge pressure reading on the control panel would not see the decrease in discharge pressure as the system is returned to normal operation. Returning the test block valve to RUN position after test opens a direct two-way connection between discharge pressure and the HPCO transducer or switch. During installation of the test block, care should be taken to minimize total system volume from the test block to the HPCO. Directly installing the HPCO on the test block will keep the volume low, and be much easier to pressurize during testing. TEST PUMP CALIBRATION KIT (720B0129G01) Figure 2. Test Block in Run Position The valve is lockable in the RUN position. PRINCIPLES OF OPERATION TEST BLOCK The test block functions as a low pressure drop check valve, not a stop valve, in the line from the discharge pressure source to the HPCO. In the RUN position the HPCO is fully open to the discharge pressure source. In the TEST position an external pressure source is connected to the test connection quick connect and when the valve is switched to TEST position, the external source is connected directly to the HPCO. This allows the function of the HPCO and pressure setting to be confirmed by application of external pressure while comparing the compressor discharge pressure reading to a master gauge. Once the HPCO is confirmed to trip the compressor at the correct set point, the valve is switched back to run mode and any high pressure trapped above the check valve is relieved back to the system. Should an actual high pressure event occur, even during testing, the check valve in the test block Figure 3. Calibration Kit in Hard Case with Hose The test pump calibration kit comes complete with hydraulic test pump, a 15 foot quick connect hose, oil reservoir, and calibrated master gauge all suitable for use with refrigeration oil as the pressurizing media. The pump is used to connect to the quick connect test port on the test block. Once the test block is switched to the TEST position, operation of the test pump will allow the technician to raise the pressure measured at the HPCO until the running unit is proven to stop at the correct cut-out pressure. The actual cut-out pressure can be compared between the pressure display on the control panel and the master gauge included with the test pump. If the reading is beyond the permissible tolerance (generally 2.5% of cut-out pressure), the control panel should be recalibrated to read correctly at the set point.

8 IO (FEB 2018) Page 8 EZ-CAL OPERATION If used to test a pressure switch, and the switch does not function to stop the compressor at the correct set point, the switch should be properly adjusted or replaced, and re-tested to show proper cut-out within tolerance. Once testing is complete the pump can be removed at the quick connect to the block, and the block can be switched back to the RUN position. Any test refrigeration oil used during the testing will drain harmlessly into the compressor sump without introducing non-condensable gas to the system. The test pump is then ready to calibrate the next compressor HPCO. OPERATION PROCEDURE EXAMPLE 1. Each technician that is using this test block and test pump for calibration should be trained in general ammonia refrigeration safety practices (or other refrigerants used). All technicians need to be aware they are dealing with high pressure toxic or flammable gases and due caution is essential to assure safety. We suggest that each facility review this example procedure and modify as necessary to assure safety in their facility. NOTICE The test block and calibration kits are refrigerant specific and the refrigerant to be used must be specified at time of order. O-ring material will vary between different refrigerants. 5. Select an oil that is compatible with the refrigeration system being calibrated and with the MECP10K pump. Frick oils 3, 9, 9S, 11, and 11S are all suitable for ammonia systems, but it is not recommended to change the oil used in the pump back and forth. Pick an oil for the pump and always use the same oil and pump together to avoid O-ring swell or shrinkage issues. 6. The pump is equipped with a safety relief valve set to 500 psi to avoid overpressure of the pump or hose during the test. This safety valve is adjustable with an allen wrench. It is advisable to test the function of the safety valve with CAUTION before the first time the pump is used to be sure it will not open at a normal test pressure. The hose and pump are designed for operation pressures well above normal refrigeration pressure. 7. Fill the reservoir to the fill line with clean refrigeration oil then reinstall the fill plug finger tight. During use do not let the reservoir drop below 50% of the reservoir capacity. (Doing so may allow air to be introduced into the test system). 2. The test block and calibration kits are refrigerant specific and must be ordered with the refrigerant to be used specified. O-ring material will vary between different refrigerants. 3. Remove test pump from hard carrying case. Inspect for any damage. 4. Familiarize yourself with the components and operation of the pump and gauge. GAUGE Gauge Display ZERO MAX MIN CONFIG ENTER Side Port 1/8 FNPT for optional Relief Valve only (P/N ) Top Port 1/4 FNPT Fill Port and Cap Vernier Control Needle Bleed Valve Fill Line Media Reservoir Stroke Limiter

9 EZ-CAL OPERATION IO (FEB 2018) Page 9 8. Use only the provided hose between the pump and block. The provided hose is rated for the system pressures it will be exposed to, and has internal check valves to prevent leakage of refrigerant into the pump or from the hose once disconnected. 12. Close needle bleed valve on pump, clockwise, and position Vernier dial about middle position. Insert quick connect fitting labeled pump end into the hand pump quick connect at red guide sleeve. It should click into place. 9. Press enter to turn on the Gauge. If the reading is not zero, press zero to adjust for atmospheric pressure. 10. The male-end of the hose connects to the test block. 11. The female-end of the hose connects to the test pump and gauge unit. 13. The hose can trap high pressure oil or gas between the pump and the check valve. Read the gauge reading to see if internal pressure is trapped in the hose from the last use. The pressure can be carefully bleed off to the reservoir by slowly opening the bleed valve. If air or refrigerant is trapped in the hose it can foam the oil in the reservoir, so open the bleed slowly if pressure is shown on the gauge. Once pressure is relieved close the bleed valve, (turn clockwise). 14. On first use the hose should be filled with oil to avoid pushing air into the system. Push the stroke limiter into the prime mode position to allow the handles to have maximum travel. Hold the center post of the block end quick connect in while working the pump handles until oil comes out of the hose end. NOTE: this can take many strokes of the pump depending on the volume of the hose and whether the pump has been used in a while. It is important to hold the reservoir reasonably level to allow the pump to properly fill between strokes. Slow operation of the pump is more effective than fast operation, to give the plunger time to properly fill on each pump stroke. 15. See image below. GA ZERO MAX MIN CONFIG ENT

10 IO (FEB 2018) Page 10 EZ-CAL OPERATION 16. Once fluid starts to exit the end of the hose switch the valve on the test block to test position and connect the hose to the test port on the test block. 17. Insert the hydraulic hose (block end) into the test port of the test block. 20. The person conducting the test should be able to see the reading from the discharge pressure sensor on the control panel begin to rise and follow the pressure increase created by the test pump once the pump pressure exceeds the discharge pressure. As the test pressure begins to approach the cut-out set-point, the stroke limiter button can be pushed in, (from the back side of pump), while the handles are squeezed together to put the pump in pump mode where the pressure increase can be controlled more precisely. NOTE: Failure to use the stroke limiter will greatly reduce the mechanical advantage the user has and will limit the maximum pressure that can be generated with reasonable handle pressure. 21. See below. 18. Equipment is now ready for testing. The block valve is shown in the test position. 22. As the test pressure approaches the cut-out set point, the final pressure adjustment can be made by turning the Vernier dial. The Vernier is capable of fine pressure adjustment but only a few psi. 23. See below. 19. Squeeze the pump handles until the master gauge starts to show a sharp rise in pressure.

11 EZ-CAL OPERATION IO (FEB 2018) Page If the HPCO fails to stop the compressor from operating when the HPCO reaches its set point, repairs will be required. The transducer on discharge pressure will need to be recalibrated to the master gauge, within allowable tolerance, (IIAR-6 proposes a maximum disagreement of 2.5% of set point pressure). A HPCO switch will need to be adjusted (if possible), or replaced. 25. See final image on Once the HPCO is proven to stop the compressor within allowable tolerance at set point, the calibration is complete and should be documented. 27. The block end of the test hose can be removed from the test block while the test valve is still in the test position. Internal check valves are used to prevent oil leakage in either direction. 29. There is still oil pressure trapped in the hose after the test. This can be left in the hose if it will be used immediately to calibrate another compressor. If not being used immediately, the pressure can be slowly bled off by opening the bleed valve on the pump. There should be no refrigerant trapped in the hose if the above procedure was followed. But, use CAUTION when bleeding the hose in case any gas is in the hose, as it will cause bubbles in the oil reservoir which can spray oil out of the reservoir, Unless a check valve fails to function there should never be ammonia vapor in the test hose, but always open the bleed valve cautiously as any vapor in the hose will be fed back to the reservoir. 30. Once the testing and calibration is complete the pump and hose can be drained of oil and safety quick connect plugs can be inserted in the test port connectors on the block and pump to keep the connections clean. 28. The test block valve can then be switched back to run position, You should observe the panel reading dropping back to the normal discharge pressure reading once the valve position is switched to run. The compressor can be restarted, as necessary, and the test block can be locked in run position with the lock ring in the handle. 31. To assure the master gauge is accurate to NIST (National Institute of Standards and Technology) it should be calibrated to a dead weight tester or master calibration gauge on a scheduled basis with certificate and date maintained.

12 Form IO ( ) Supersedes: NOTHING Subject to change without notice Published in USA 02/18 PDF 2018 Johnson Controls Int'l PLC - ALL RIGHTS RESERVED JOHNSON CONTROLS 100 Cumberland Valley Avenue Waynesboro, PA USA Phone: FAX:

MANUAL BE SERIES Test Benches

MANUAL BE SERIES Test Benches The CustomCrimp Manual BE Series Test Benches are designed with features that make proof and burst testing of hydraulic hose assemblies a quick and easy procedure. CUSTOMIZED AND SPECIAL DESIGN BENCHES

More information

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-15 OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE

More information

OPERATION MANUAL NTF-60 Plus

OPERATION MANUAL NTF-60 Plus OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)

More information

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289 3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for

More information

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier Tentec Page 1 w w w. t e n t e c. n e t Instruction Document Mini Air Driven Pump Unit Model: HTT.627X Series HTT.6271 Maximum Working Pressure = 1500bar (21750 psi) HTT.6272 Maximum Working Pressure =

More information

WIKA INSTRUMENT CORPORATION

WIKA INSTRUMENT CORPORATION WIKA INSTRUMENT CORPORATION Instruction Manual DIFFERENTIAL PRESSURE GAUGE Series 1500 Series 1000 Series 300 WIKA Instrument Corporation 1000 Wiegand Boulevard Lawrenceville, GA 30043 1-888-945-2872 http://www.wika.com

More information

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax: 2 Table Of Contents 1. Introduction 3 2. About this Manual 3 3. Contacting YZ Systems 3 4. Vessel Components 4 5. Specifications 5 6. Application 6 7. Theory of Operation 7 8. DuraSite Installation & Use

More information

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to: HANDBOOK Squeeze Off Unit SOU 400 Please refer any queries to: Hy Ram Engineering Co Ltd Pelham Street Mansfield Nottinghamshire NG18 2EY Telephone No: (01623) 422982 Please note all queries should state

More information

Installation Instructions

Installation Instructions LP and High Altitude LP Gas Conversion Kit For United States Installations Installation Instructions For Model Series *G6/PGF1 Furnaces, *L1/PGC1 Furnaces, and *R4/PPG1 Gas/Electric Appliances using Honeywell

More information

NGP-250/500 Nitrogen Generator Quick Start Guide

NGP-250/500 Nitrogen Generator Quick Start Guide NGP-250/500 Nitrogen Generator Quick Start Guide Version: A July 2013 Potter Electric Signal Company, LLC 5757 Phantom Dr., Suite 125 P. O. Box 42037 Hazelwood, MO 63042 Phone: (314) 595-6900 Document

More information

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com

More information

COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE Rohrback Cosasco Systems, Inc. 11841 E. Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 www.cosasco.com

More information

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09 PRESSURE TEST PUMP Model No: PTP00 Part No: 06020 OPERATING & MAINTENANCE INSTRUCTIONS GC0/09 INTRODUCTION Thank you for purchasing this CLARKE Pressure Testing Pump. Before attempting to use the product,

More information

Constant Pressure Crude Oil Container Model CPCCP

Constant Pressure Crude Oil Container Model CPCCP Installation, Operations, and Maintenance Manual Constant Pressure Crude Oil Container Model CPCCP The information in this manual has been carefully checked for accuracy and is intended to be used as a

More information

R E D I C O N T R O L S

R E D I C O N T R O L S R E D I C O N T R O L S Operation & Maintenance Manual Portable Service Purger for Low Pressure Chillers Model: PSP-LP-1B For Refrigerants R-11, R-113, R-114 & R-123 & Other Similar Refrigerants File Literature

More information

KJ4000 Operating Instructions & Parts Manual NSN

KJ4000 Operating Instructions & Parts Manual NSN KJ4000 Operating Instructions & Parts Manual NSN 1025-01-473-7710 Mandus Group Ltd. KJ4000 Operators Manual Date: 3 Jan. 2002 TABLE OF CONTENTS General Safety Instructions...Page 1 Operator Instructions...Page

More information

Spirax Compact FREME Flash Recovery Energy Management Equipment

Spirax Compact FREME Flash Recovery Energy Management Equipment IM-UK-cFREME UK Issue 1 Spirax Compact FREME Flash Recovery Energy Management Equipment Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.

More information

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels 12.09 product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels Introduction: This manual covers the installation and operation of Humboldt FlexPanels for Triaxial and Permeability

More information

TECHNICAL MANUAL CALIBRATION PROCEDURE FOR PRESSURE GAUGE. This publication replaces T.O. 33K dated 30 January 2012.

TECHNICAL MANUAL CALIBRATION PROCEDURE FOR PRESSURE GAUGE. This publication replaces T.O. 33K dated 30 January 2012. TECHNICAL MANUAL CALIBRATION PROCEDURE FOR GAUGE This publication replaces T.O. 33K6-4-427-1 dated 30 January 2012. Distribution Statement C - Distribution authorized to U. S. Government agencies and their

More information

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT P.O. Box 1058 1058 West Industrial Avenue Guthrie, OK 73044-1058 405-282-5200 FAX: 405-282-8105 www.autoquip.com Item # 830ABS Version 1.0 07/2001

More information

12V AIR STATION ALL-IN-ONE

12V AIR STATION ALL-IN-ONE [ACT 027] Manual E 6/9/05 10:18 PM Page 3 Multi use 12V AIR STATION ALL-IN-ONE OWNER S MANUAL MODEL NO: C71A-54 KEEP THE ORIGINAL BOX, PACKAGING AND RECEIPT. BEFORE OPERATING THIS UNIT, READ THE MANUAL

More information

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures Operations & Service Manual TESCOM 50-4X Series Safety, Installation & Start-Up Procedures Do not attempt to select, install, use or maintain this product until you have read and fully understood this

More information

User Instruction Manual

User Instruction Manual User Instruction Manual 4500 psi Air Compressor Ver 2, 1.18 Contents Parts Included...3 Assembly Instructions...3-5 Operation Instructions...6-7 Oil Change Intervals...8 Air Filter Replacement...9 Setting

More information

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS Installation Instructions For Model Series *G7/*GC2 Furnaces and Appliances Using Honeywell Gas Valves. BEFORE THE CONVERSION

More information

Section 3- Repair and Calibration Procedures

Section 3- Repair and Calibration Procedures Section 3- Repair and Calibration Procedures 1. Refrigerant Removal Procedures 2. Scale/PC Board Recalibration Procedure 3. PC Board Configuration Procedure of AR400 4. Scale Tare Procedure 5. Gauge Calibration

More information

Wilo Triple Duty Valve / Triple Service Valve Installation and operating instructions

Wilo Triple Duty Valve / Triple Service Valve Installation and operating instructions Wilo Triple Duty Valve / Triple Service Valve Installation and operating instructions WIL-IO-SD-001-10 1 Description The Triple Duty Valve (TDV) / Triple Service Valve (TSV) is a quiet operating heavy-duty

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS 1NP0680 - PROPANE CONVERSION FOR USE WITH MODELS: PM8, PC8, PM9, PC9, FL9M, FL9C, FC9M, FC9C This conversion kit is to be installed by a qualified service agency

More information

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock or Electrocution: MODEL NUMBER: 20008 200 PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT: It is

More information

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION Jackco Transnational Inc. 202 South El Monte, CA 888-452-2526 www.jackco.com FOR YOUR SAFETY Read all instructions, warnings and cautions carefully. Follow all

More information

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to: HANDBOOK Squeeze Off Unit SOU 250 Please refer any queries to: Hy Ram Engineering Co Ltd Pelham Street Mansfield Nottinghamshire NG18 2EY Telephone No: (01623) 422982 Please note all queries should state

More information

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80589-02 Table of Contents Components... 2 Test... 4 Recovery/Recycling... 5 Evacuation... 7 Charging...

More information

NTF-230 OPERATION MANUAL

NTF-230 OPERATION MANUAL NTF-230 OPERATION MANUAL MAHLE Aftermarket Inc., Service Solutions 10 Innovation Drive York, Pennsylvania 17402 USA Phone: 717-840-0678 Toll Free: 800-468-2321 Web-site: www.servicesolutions.mahle.com

More information

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions Jacuzzi J-CQ420 Cartridge Filter Installation and Operating Instructions IMPORTANT SAFETY PRECAUTIONS ATTENTION INSTALLER: This guide contains important information about the installation, operation and

More information

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE MODEL NUMBER: M20005 AIR SOURCE KIT 30% Duty Compressor on 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock

More information

Pressure Regulators. Operating Instructions. Instrumentation

Pressure Regulators. Operating Instructions. Instrumentation Pressure Regulators Operating Instructions FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THIS PRODUCT CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from the

More information

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150 Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150 January 2013 Form FVC 084 - Rev 02 IMPORTANT: KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER. 1.

More information

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use. AWG Fittings LLC Pressure Relief Valve Up to 250 PSI Product Number 30004033 Read this instruction manual before use. Using this device without t understanding di this products operation and care may lead

More information

MMR Air Mask With. with Quick-Connect Hose

MMR Air Mask With. with Quick-Connect Hose MMR Air Mask With with Quick-Connect Hose Upgrade Kits P/N 10025120 Slide to Connect P/N 10050038 Slide to Connect w/ Solid Cover P/N 10038666 Push To Connect P/N 10050037 Push To Connect w/ Solid Cover

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established

More information

Rejuvenation Instructions

Rejuvenation Instructions Rejuvenation Instructions #401 Air Systems UPR This NRI covers the following: Understanding the applications and operation of flow meters. Understand the application and operation of test pressure gauges.

More information

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS READ ALL INSTRUCTIONS PRIOR TO INSTALLATION AND OPERATION TO AVOID POSSIBLE INJURY Warning: Always consider any accumulator to contain pressure until proven

More information

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150, CARTRIDGE FILTERS Models: CF50, CF75, CF00, CF50, The installation of this product should be carried out by a qualified pool technician, following the installation instructions provided in this manual.

More information

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator. LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the

More information

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP LIMITED WARRANTY Getz Equipment Innovators warrants its products, and component parts of any product manufactured by

More information

Model 106 DPI "Micro-switch" Installation and Operating Instructions

Model 106 DPI Micro-switch Installation and Operating Instructions Mid-West Instrument Model 106 DPI "Micro-switch" Installation and Operating Instructions BULLETIN NO. IM116DPImicro/09A Replaces --- INSPECTION Before installation carefully check the Model Number on each

More information

30T A/Manual Hydraulic Shop Press

30T A/Manual Hydraulic Shop Press 30T A/Manual Hydraulic Shop Press Operation Manual 1 1. Important Information 1.1 Safety Information 1.1.1 Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when

More information

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com P5513 Pneumatic Comparison Test Pump Users Manual PN 3963372 November 2010 2010 Fluke Corporation. All

More information

FV Flash Vessel Installation and Maintenance Instructions

FV Flash Vessel Installation and Maintenance Instructions 4041050/5 IM-P404-10 EMM Issue 5 FV Flash Vessel Installation and Maintenance Instructions 1. Safety information 2. Specific product safety information 3. Product information 4. Installation 5. Commissioning

More information

COSASCO 6000 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

COSASCO 6000 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE COSASCO 6000 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE 11841 Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 www.cosasco.com Page: 2 of 26 Revision

More information

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors 0862050/1 IM-P086-18 MI Issue 1 Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors Installation and Maintenance Instructions 1. Safety Information 2. General product information 3. Installation 4.

More information

DPC-30 DPC-100. Reference Manual

DPC-30 DPC-100. Reference Manual DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,

More information

Installation and Service Manual

Installation and Service Manual An Actuant Company Installation and Service Manual Heavy Duty Hydraulic Stabilization Legs CONTENTS Part # 3010003129 REV 0D Section Page 1.0 Receiving Instructions 2 2.0 Safety Issues 2 3.0 Hydraulic

More information

FAULT CODE TROUBLESHOOTING INDEX

FAULT CODE TROUBLESHOOTING INDEX FAULT CODE TROUBLESHOOTING INDEX 1. Display indicates Change Filters 2. Display indicates Drip Tray Full Continuous Alarm will Sound 3. Display indicates Cold Fault 4. Display indicates Hot Fault 5. Display

More information

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation PRESSURE COMPARATOR GauGeCaLXP 10000PSI 700bar Operator Instructions Page 2 GaugeCalXP Operator Instructions PRESSURE is Our BUSINESS Introduction Thank you for purchasing a GaugeCalXP Pressure tor from

More information

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY FOR USE

More information

Types 749B and R130 Changeover Manifolds

Types 749B and R130 Changeover Manifolds Instruction Manual MCK-1179 Types 749B and R130 June 2012 Types 749B and R130 Changeover Manifolds TYPE HSRL-749B TYPE 64SR/122 TYPE R130/21 TYPE 749B/21 Figure 1. Changeover Manifolds and Regulator Assemblies

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves Tools Required: Flow Meter Pressure gauge Holding valve test block Wrenches for installation of

More information

User Manual Pressure Calibration System C and Hydraulic Pressure Pump Models T-620/T-620H Copyright 2008 AMETEK Denmark A/S

User Manual Pressure Calibration System C and Hydraulic Pressure Pump Models T-620/T-620H Copyright 2008 AMETEK Denmark A/S User Manual Pressure Calibration System C and Hydraulic Pressure Pump Models T-620/T-620H Copyright 2008 AMETEK Denmark A/S About this manual. The structure of the manual This user manual is aimed at users

More information

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

XpressFill XF2500 Counter Pressure Filler. Operating Instructions XpressFill XF2500 Counter Pressure Filler Operating Instructions ii XPRESSFILL Systems LLC lling machine. ank you for choosing our handcrafted bottle filler as the technology to bottle your passion. We

More information

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR MODEL NUMBER: 45043-450P-A AUTOMATIC PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and

More information

Operating Instructions and Parts Manual 24529

Operating Instructions and Parts Manual 24529 Please read and save these instructions. Read through this owner s manual carefully before using product. Protect yourself and others by observing all safety information, warnings, and cautions. Failure

More information

AIR/OVER HYDRAULIC JACK 20 TON

AIR/OVER HYDRAULIC JACK 20 TON AIR/OVER HYDRAULIC JACK 0 TON 4487 ASSEMBLY AND OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com Copyright 999 by Harbor Freight Tools.

More information

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD OPERATORS ORS GUIDE REL-510H 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD Compatible with U style and RELIABLE R12 shell type 12 ton compression dies. RELIABLE EQUIPMENT & SERVICE CO., INC. 92 Steamwhistle

More information

36H SERIES Combination Gas Valve

36H SERIES Combination Gas Valve FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION The 36H series combination gas valve is

More information

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website: 1.0 Inspection of the product upon receipt: On receipt of the product, visually inspect the item for any evidence of shipping damage. Please note shipping damage is not covered by warranty. If shipping

More information

Model No.: SFC-ED Torque Tool Serial No.: SFC Ref No.:

Model No.: SFC-ED Torque Tool Serial No.: SFC Ref No.: Model No.: SFC-ED Torque Tool Serial No.: SFC Ref No.: CONTENTS 1 Contents Page & Introduction 2 Training Requirements & General Safety 3 SFC ED Tool Models Covered By Manual Noise & Vibration Levels 4

More information

Portable Oil Lube Air Compressors

Portable Oil Lube Air Compressors Portable Oil Lube Air Compressors 8003631 8003632 0410149 8018968 8018940 Owner s Manual Read and understand operating instructions before use Safety definitions The information listed below should be

More information

20 Ton SD Shop Press Operating Instructions

20 Ton SD Shop Press Operating Instructions 20 Ton SD Shop Press Operating Instructions MODEL NO. 850SD Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when the operations or maintenance job involves a potential

More information

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT 200 PSI FAST-FILL AIR SOURCE KIT 55% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20007 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY

More information

SAMPLE WRITTEN PROGRAM for Control of Hazardous Energy LOCKOUT TAGOUT

SAMPLE WRITTEN PROGRAM for Control of Hazardous Energy LOCKOUT TAGOUT SAMPLE WRITTEN PROGRAM for Control of Hazardous Energy LOCKOUT TAGOUT SAMPLE WRITTEN PROGRAM The objective of this procedure is to establish a means of positive control to prevent the accidental starting

More information

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT 200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION DUAL SUPPLY REGULATOR ESCAPE CYLINDER VORTEX MAIN INLET PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY

More information

Model: 43T. Bermad Pressure Relief Valve

Model: 43T. Bermad Pressure Relief Valve Model: 43T Bermad Pressure Relief Valve Installation Operation Maintenance Manual () Rev.C1_01.08.17 Page 1 of 10 Safety First BERMAD believes that the safety of personnel working with and around our equipment

More information

ACCESSORY KIT INSTALLATION MANUAL

ACCESSORY KIT INSTALLATION MANUAL ACCESSORY KIT INSTALLATION MANUAL LP (PROPANE) CONVERSION KIT 1NP0366 FOR USE WITH MODELS: G8C & GF8 This conversion kit shall be installed by a qualified service agency in accordance with these instructions

More information

Operating Procedure TITON SUBSEA BOLT TENSIONER

Operating Procedure TITON SUBSEA BOLT TENSIONER Operating Procedure TITON SUBSEA BOLT TENSIONER B & A Hydraulics Ltd Block 1, Units 1 & 2 Souter Head Industrial Centre Souter Head Road Altens Aberdeen Phone: 01224 898955 Fax: 01224 898787 E-Mail: TITON@bahyd.co.uk

More information

TECHNICAL DATA Q= C. Table 1 - Specifications

TECHNICAL DATA Q= C. Table 1 - Specifications September 25, 2013 Pressure Regulation 537a 1. Description The Model B-3 Pilot Operated Pressure Control Valve is a factory assembled unit. The unit consists of a Model J-2 Halar coated Flow Control Valve,

More information

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES EXTREME SERIES PART NO. 45043 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS

More information

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES 450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES PART NO. 45053 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing

More information

1 DRIVE INDUSTRIAL IMPACT WRENCH

1 DRIVE INDUSTRIAL IMPACT WRENCH 1 DRIVE INDUSTRIAL IMPACT WRENCH 92622 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2004 by Harbor Freight

More information

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road PROPORTIONING VALVE Model 150 INSTRUCTION MANUAL March 2017 IMS Company 10373 Stafford Road Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: sales@imscompany.com 1 Introduction IMS Company reserves

More information

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS VERTICAL AIR COMPRESSORS MODEL NO: VE11C150, VE15C150, VE18C150 PART NO: 2226005, 2226000, 2226015 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE Vertical

More information

Natural Gas to L.P. Gas Conversion Kit

Natural Gas to L.P. Gas Conversion Kit Natural Gas to L.P. Gas Conversion Kit For Bosch 80% AFUE Gas Furnace, BGS80 Model Installation Instructions 3124627 2 Natural Gas to L.P. Gas Conversion Kit Installation Instructions Data subject to change

More information

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013 Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release

More information

FOR TM TURRET COMBAT ENGINEER VEHICLE, M728 ( ) TECHNICAL MANUAL

FOR TM TURRET COMBAT ENGINEER VEHICLE, M728 ( ) TECHNICAL MANUAL TECHNICAL MANUAL DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL PART 4 MAINTENANCE TURRET FOR COMBAT ENGINEER VEHICLE, M728 (2350-00-795-1797) This copy is a reprint which includes current pages

More information

COSASCO 6000 PSI DOUBLE ISOLATION SERVICE VALVE MAINTENANCE

COSASCO 6000 PSI DOUBLE ISOLATION SERVICE VALVE MAINTENANCE COSASCO 6000 PSI DOUBLE ISOLATION SERVICE VALVE MAINTENANCE 11841 Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 www.cosasco.com Page: 2 of 28 Revision History

More information

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters ADI 3210-A ADI 3210-A Certified ISO 9001 Certified ISO 9001 High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters Warning: An appropriately sized pressure relief device downstream of the regulator

More information

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator. PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Thank You for Attending Today s Webinar. Today s Featured Speaker

Thank You for Attending Today s Webinar. Today s Featured Speaker Thank You for Attending Today s Webinar Your Host Mike DeLacluyse President Lesman Instrument Company miked@lesman.com Today s Featured Speaker A.J. Piskor Combustion & Controls Specialist Lesman Instrument

More information

Document How to Set Single Stage Press Pressures

Document How to Set Single Stage Press Pressures Published Document Number: IIFUUC01 Specified Date: 20040701 As-of Date: 20040701 Access Date: 20040701 Depth: detail Applicability: not used Language Code: ENG01, Purpose: publication, Format: 1colA Document

More information

KJ1000 Operating Instructions & Parts Manual NSN

KJ1000 Operating Instructions & Parts Manual NSN KJ1000 Operating Instructions & Parts Manual NSN 1025-01-473-8886 ISO 9001 Certified June 2004 MANDUS GROUP Rev. 2/11 Mandus Group Ltd. KJ1000 Operators Manual TABLE OF CONTENTS General Safety Instructions...Page

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE MODELS RV-1 RV-2 RV-2CP RV-3 DRAWING NUMBERS AD017A[ ] AD018A[ ] AD020A[ ] AD282BO MANUAL NUMBER IOM-033 REVISION Rev. E, 3/28/2016 TABLE

More information

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A. Gas Lines Technical Manual Sumitomo (SHI) Cryogenics of America, Inc. 1833 Vultee Street Allentown, PA 18103-4783 U.S.A. Revision F: April 2008 261320A TABLE OF CONTENTS Page DESCRIPTION...1 SPECIFICATIONS...2

More information

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N) 1 APPLICABILITY Exhibit 4 Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N) Definitions common to all certification and test procedures

More information

DuPage County Environmental, Safety, Health & Property Loss Control Program Hazardous Energy Control (Lockout/Tagout)

DuPage County Environmental, Safety, Health & Property Loss Control Program Hazardous Energy Control (Lockout/Tagout) Purpose: To provide the minimum requirements for the lockout or tagout of energy isolating devices whenever work is performed or servicing is done on County of DuPage machinery, equipment, vehicles and

More information

PDY TON HYDRAULIC CRIMPING TOOL WARNING

PDY TON HYDRAULIC CRIMPING TOOL WARNING OPERATORS ORS GUIDE PDY-1220 12 TON HYDRAULIC CRIMPING TOOL All information found in this guide must be read and understood before use or testing of this tool. Failure to read and understand these warnings

More information

INSTRUCTIONS FOR MODELS UPH & UPHS HIGH FLOW, HIGH PURITY GAS REGULATORS

INSTRUCTIONS FOR MODELS UPH & UPHS HIGH FLOW, HIGH PURITY GAS REGULATORS INSTRUCTIONS FOR MODELS UPH & UPHS HIGH FLOW, HIGH PURITY GAS REGULATORS THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY

More information

MODEL NUMBER: AS18-2 USER GUIDE

MODEL NUMBER: AS18-2 USER GUIDE Compressor MODEL NUMBER: AS18-2 USER GUIDE WEBSITE: EMAIL: www.airbrushheaven.co.uk enquiries@airbrushheaven.co.uk 1 YEAR WARRANTY Contents 1. Welcome Section 2. General Information & Safety Instructions

More information