Hatchery Tips from Jamesway s Technical Team. Essential Hatchery Tools by Phillip Perry

Size: px
Start display at page:

Download "Hatchery Tips from Jamesway s Technical Team. Essential Hatchery Tools by Phillip Perry"

Transcription

1 Hatchery Tips from Jamesway s Technical Team Essential Hatchery Tools by Phillip Perry

2 HATCHERY TOOLS FOR A JAMESWAY HATCHERY by Phillip Perry, Consultant and Technical Advisor Phillip is a former hatchery manager and has spent his life in the incubation/poultry world. His input on managing a hatchery is invaluable. We hope you enjoy his article on hatchery tools. The Bitter Taste of Poor Quality Lingers Long after the Sweetness of Low Price is Forgotten. Probably the best piece of advice I got when I started to work for Jamesway as a consultant to hatcheries was to carry my own tools. The truth is that often the hatcheries I would visit would not have the proper tools for the job, they would be broken or just too cheap to work properly; sometimes they simply could not be found. A basic set of tools should always be available at every hatchery for routine maintenance and troubleshooting so I have created a check list which should outline the most essential tools for managing your hatchery.

3 BASIC HAND TOOLS Screwdrivers A multi tool screwdriver is handy and with an assortment of bits eliminates the need to carry around a pouch full of screw and nut drivers. Electric Screwdrivers - Manually screwing and tightening can be a killer on the arms and wrist. There are many electric screwdrivers available with plenty of torque such as the Dewalt 8-volt. These hold a myriad screwdriver bits to use the correct driver for the job. Jamesway equipment requires Slotted, Philips, and Robertson drivers. Pliers Linesman s, needle nose, Channellocks, vise grips etc... An assortment of pliers is needed in the hatchery tool box for various gripping and cutting jobs. Needle nose pliers are great for inserting (or removing) wire in terminal blocks. Wrenches All Jamesway equipment uses SAE American Standard. Ratchet wrenches enable you to work more quickly and efficiently. You also have an easier time fastening or removing bolts and nuts in cramped spaces. An adjustable wrench is also a great pocket tool to carry when doing machine checks. Handy sizes 3/8 for damper adjustment and 7/16 for airlines. Other Tools Cordless drill and bits. VOM Multimeter. Socket Set (SAE). Measuring Tape. Hammer Flashlight. A VOM multi-meter is a combination of a multi-range DC/AC voltmeter, ammeter, and ohmmeter. Measurements needed for Jamesway electronic equipment.

4 SPECIFIC TOOLS FOR MULTI-STAGE Some of the Jamesway machines have specific tool requirements which have been developed by Jamesway or are part of our recommendation for optimization of machine performace. The following tools pertain to our Multi-Stage machines. HA1145 Incubator rack testing device, connects to rack turn cords to test left and right turning. The turning of your eggs is essential so always want to be sure of your rack s ability to turn. This device will help to detect a turn failure before it affects your hatch. Test racks with eggs in egg storage before setting eggs in your incubator. A Clamp Amp Meter is an electrical device with jaws to allow clamping around heater rods. This allows measurement of the current without the need to make physical contact. Incubators should measure amps, Hatchers 7-8 amps.

5 SPECIFIC TOOLS FOR SINGLE-STAGE ECU Water Flow Tester This device can be attached to the ECU water return and includes a flow meter to assess the GPMs, dial thermometer to check water temperature and pressure gauge to check water pressure coming out of ECU. This helps to optimize the equipment and maintain high standards in your hatchery. Brass Couplers HA1143P Plastic Coupler HA1153 Shark Bite HA1160 ACI P1 P2 P80-P120 incubators have greater water requirements than other machines as they have two (2) ECUs compared to one (1) ECU for other machines. Easily disconnect Shark Bite fittings in hard to reach places with Disconnect Tongs. Jamesway uses ½ Shark Bite Fittings CO 2 Calibration The carbon dioxide sensor should be checked regularly to ensure continued sensor accuracy. There are two options for calibration: either a gas meter or calibration gas. Jamesway sells the HA1155 CO2 meter and calibration gas with regulators can be purchased on line or from a local gas company. If calibration is necessary, perform the zero point calibration first, followed by span calibration.

6 TEMPERATURE CALIBRATION SS AND MS For temperature calibration Jamesway recommends the HA1070 Digital Thermometer with HA1071 plastic probe. The HA1152 temperature and humidity is very useful for calibration between your machines, ventilation software, communication systems and displays, etc. Part of every hatchery technician s toolkit. Be sure to request certification when ordering to ensure accuracy. Always label and keep the same probe with same digital thermometer since probes are only calibrated to a specific digital thermometer. Temperature can vary when sharing multiple instruments and probes.

7 VENTILATION TOOLS Properly controlled ventilation is essential to the success of any hatchery and Jamesway provides the Guardian HVAC control system to give customers the control they need. The HA1150 Handheld digital manometer measures differential pressures in a wide variety of applications for room and Multi- Stage equipment. A simple way to check if the current air supply into a setter/hatcher room is adequate is to measure the room pressure. When measuring room pressure while within a room, place one end of tubing on (-) port and place the other end outside, with the (+) port open to the space being measured. A calibrated humidity and temperature measuring device is also a must, for calibrating your sensors. We recommend using the Electrotherm, as you can measure both in one convenient device (part HA1152). A reliable multimeter, with the ability to measure current, is also necessary, for troubleshooting the system. A good set of electrical screwdrivers are necessary for replacing components and testing. An anaemometer is a good reference tool to give you an idea of the airflow from your units.

8 PILOT AND HATCHSENSE Whether used to control your machine, or just as a tool to give the feedback necessary to fine-tune your profiles, Pilot and Hatchsense are invaluable tools giving insight into what is actually happening in your machine. What better way to check on your eggs than to see the eggshell temperature, or check on your chicks by confirming movement and a humidity peak. The Pilot System is a sensor system that accurately and consistently monitors the temperature of eggs in an incubator. It ensures that the temperature settings inside the incubator are adequately adjusted to provide the proper amount of heating and cooling for ideal embryo development. HatchSense comprises sensors that are attached to a stack of plastic hatcher baskets. HatchSense automatically monitors the eggs, detects when the first birds hatch, and adjusts the environment to decrease the hatch window (the time from the first to the last chick hatching). HATCHCOM The final most important tool is Hatchcom. Having real-time data from your ventilation and incubators and hatchers gives you the most power in running your hatchery. Hatchcom also gives you the unique ability to profile your multi-stage hatchers, as well as to schedule your Guardian HVAC controls. This degree of fine tuning is precisely what is needed to produce exceptional chicks.

9 TROUBLESHOOTING PROBLEMS As with all systems, there will be occasional mechanical breakdown or electronic failure. Unfortunately for technicians and those on call this usually occurs 2 a.m. on weekends. Always be aware of safety concerns and identify the hazards. Before opening the control box or panel, an inspection of the appropriate mechanical operations may uncover the source of a problem. Are several units alarming or just one? Are the inputs correct power, hot and cold water, air, humidity supply? Charts in Operation Manuals outline a course of action to be followed beyond the mechanical operations and into the electronic board level of our Control Systems. By following these flow charts you can, by process of elimination, solve most problems. Manuals Page for troubleshooting guide PT PS P1 SS 93 P2 SS 71 Guardian Complete Guide For copies of User s Manuals go to One common method that I like to use is the split-half troubleshooting approach: With a problem resulting from a number of possibilities in the flow chart, one tests half-way down the line of components. If the middle component works, one goes to the middle of the remaining parts, approaching the end. If the test finds a problem at the mid-point, one does a split towards the start of the line until the problem part is found. The split-half process can save time when the flow chart has many components to test. I also advise to read through the complete chart before attempting to diagnose. A good approach to troubleshooting is to ask What is the simplest thing that can be wrong

10 ORGANIZING SPARE PARTS Practical spare part management is the foundation for reliable hatchery operation and is crucial to its success. A spare parts inventory does not have to be all-encompassing to be effective. To achieve better control over inventory, define and categorize spares. Designations such as critical spares can help you prioritize your inventory. The most typical cause for out of stock parts is the delay that may exist within a supply chain (internally/externally). Properly storing and organizing spare parts in a designated, secure space is beneficial when a crucial part needs replaced. Some hatcheries have more than one incubator type and it is easy for parts to get mixed. Some Jamesway hatcheries have Multi-Stage, P1, and P2 within the same hatchery. A prompting for reorder will not take place if a part is taken without a record. Likewise, if new stock is placed on the shelf without a record, it cannot be accounted for. A review and analysis of your storage and check-out system can reveal reasons for stock inaccuracies. Jamesway s online parts store makes it easy to add parts to your cart the minute you are using them, rather than waiting to call in during business hours. Used parts can often accumulate during a desperate emergency trying to get a machine back on. They may or may not work and should be tested at a more convenient time or thrown out. Remember When in doubt Throw it out!

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road PROPORTIONING VALVE Model 150 INSTRUCTION MANUAL March 2017 IMS Company 10373 Stafford Road Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: sales@imscompany.com 1 Introduction IMS Company reserves

More information

AVIATION MAINTENANCE TECHNOLOGY REQUIRED TOOL LIST

AVIATION MAINTENANCE TECHNOLOGY REQUIRED TOOL LIST AVIATION MAINTENANCE TECHNOLOGY REQUIRED TOOL LIST REVISED 9/1/17 (per AVM Student Handbook) Tools are not needed the first day of class but are required by the second semester of class. TOOLS Under our

More information

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii Operator s Manual Table of Contents Operator Safety... 1 Introduction... 2 Unpacking and Setup... 3 Unpacking... 3 Setup... 4 FLYER Overview... 5 FLYER Diagram... 5 Capabilities... 5 Control Panel... 6

More information

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin Electronic Control Manual 216 Sensors and Stats Section S Technical Bulletin CDS-2000 Issue Date 0393 CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin Introduction 3 Pre-Verification

More information

How to... The only equipment required for measuring eggshell temperature is a medical infrared ear thermometer. It is recommended to use a Braun

How to... The only equipment required for measuring eggshell temperature is a medical infrared ear thermometer. It is recommended to use a Braun The Procedure for Measuring Eggshell Temperature The only equipment required for measuring eggshell temperature is a medical infrared ear thermometer. It is recommended to use a Braun ThermoScan ExacTemp

More information

Operating Instructions for Cobra and Lynx Duct Leakage Testers

Operating Instructions for Cobra and Lynx Duct Leakage Testers Operating Instructions for Cobra and Lynx Duct Leakage Testers Table of Contents Introduction Introduction... 2 Safety Precautions Safety Precautions.. 2 Prior to Testing System Preparation.. 4 Power Requirements...

More information

222 Schwinn Recumbent Exercise Bike Parts List Full Size Hardware Chart Product Illustration Assembly Instructions

222 Schwinn Recumbent Exercise Bike Parts List Full Size Hardware Chart Product Illustration Assembly Instructions 222 Schwinn Recumbent Exercise Bike Parts List Full Size Hardware Chart Product Illustration Assembly Instructions FITNESS SAFEGUARDS AND WARNINGS Before starting any exercise program, consult with your

More information

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302 SL 40-399 G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302 If converting from Propane to Natural Gas, order the Natural Gas Conversion Parts Kit (IBC Part # P-303) from your authorized IBC Distributor.

More information

DISCLAIMER & COPYRIGHT CONTENTS

DISCLAIMER & COPYRIGHT CONTENTS DISCLAIMER & COPYRIGHT No part of this publication may be duplicated or edited in any form or by any means, including any type of electronic or mechanical method without prior written permission from ShowTe.

More information

MoveRoll Conveyor Operating and Maintenance Manual

MoveRoll Conveyor Operating and Maintenance Manual MoveRoll Conveyor Operating and Maintenance Manual 1. Read this first! This manual contains information for protection of personnel in the roll handling area from possible injury and/or equipment damage.

More information

RAI-M series RUDDER ANGLE INDICATOR SYSTEM

RAI-M series RUDDER ANGLE INDICATOR SYSTEM RUDDER ANGLE INDICATOR SYSTEM RAI-M series SEAFIRST ENGINEERING CO 45-16, Ga Um Dong, Chang Won, Kyong Nam Korea Tel : 82 55 267 1645 Fax ; 82 55 266 1646 http://www.seafirst.co.kr GENERAL Seafirst Rudder

More information

UsER manual for Watersens ph -REDOX

UsER manual for Watersens ph -REDOX UsER manual for Watersens -REDOX Cl 8 1 2 6 3 3 7 7 4 4 4 4 Parts List 1 Redox Probe 1 x 2 PH Probe 1 x 5 Tube Weight 2 x 6 Connection Valve 1 x chlorine 3 Chlorine and Pumps 2 x 7 Dosing Valve 2 x 5 5

More information

SL G3 - Fuel Conversion to Natural Gas (LP to NG) P-Kit 301

SL G3 - Fuel Conversion to Natural Gas (LP to NG) P-Kit 301 SL 26-260 G3 - Fuel Conversion to Natural Gas (LP to NG) P-Kit 301 Note If converting from Natural Gas to Propane, order the Natural Gas Conversion Parts Kit (IBC Part # P-300) from your authorized IBC

More information

SL G3. Warning

SL G3. Warning Important: If converting from Propane to Natural Gas - order the Natural Gas Conversion Parts Kit (IBC Part # P-307) from your authorized IBC Distributor. Use the Propane Gas conversion parts kit if the

More information

Automatic Isokinetic Sampler. ST5 Evo

Automatic Isokinetic Sampler. ST5 Evo Automatic Isokinetic Sampler ST5 Evo Automatic Isokinetic Sampler ST5 Evo Moreover, in case of pump failure, the CU can work with a spare Dado PU unit or with any pump capable to supply the needed flowrate,

More information

User Manual for the Mars Calibration Bench

User Manual for the Mars Calibration Bench User Manual for the Mars Calibration Bench Fall 2013 Table of Contents Table of Contents Table of Contents... iii Introduction... v Chapter 1: The Mars Calibration Bench... 1 What Is the Mars Calibration

More information

Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves

Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves Monday Morning Minutes by Norm Hall, August 20, 2018 The flow balance of a hydronic system is a critical component in the commissioning of

More information

Tooling List 3/8 Ratchet 3/8-10mm Deep Socket 10mm Wrench 3mm Allen Wrench #2 Phillips Screwdriver Large Jaw Pliers Needle Nose Pliers

Tooling List 3/8 Ratchet 3/8-10mm Deep Socket 10mm Wrench 3mm Allen Wrench #2 Phillips Screwdriver Large Jaw Pliers Needle Nose Pliers Thank you for purchasing the CorkSport Cold Air Intake System. Help your ND Miata breathe easy with the CorkSport Cold Air Intake System. The CorkSport CAI features a CAD designed ABS box and lid, billet

More information

Precision Liquid Settlement Array Manual

Precision Liquid Settlement Array Manual Precision Liquid Settlement Array Manual All efforts have been made to ensure the accuracy and completeness of the information contained in this document. RST Instruments Ltd reserves the right to change

More information

Model 106 DPI "Micro-switch" Installation and Operating Instructions

Model 106 DPI Micro-switch Installation and Operating Instructions Mid-West Instrument Model 106 DPI "Micro-switch" Installation and Operating Instructions BULLETIN NO. IM116DPImicro/09A Replaces --- INSPECTION Before installation carefully check the Model Number on each

More information

Converting a 2006 Royal Enfield Classic to a Kick Start Only Machine. There are good reasons for not having an electric start.

Converting a 2006 Royal Enfield Classic to a Kick Start Only Machine. There are good reasons for not having an electric start. Converting a 2006 Royal Enfield Classic to a Kick Start Only Machine Reasons There are good reasons for not having an electric start. They are: 1. Reliability. There simply are fewer parts to fail. When

More information

Understanding Hatchery Ventilation

Understanding Hatchery Ventilation Understanding Hatchery Ventilation By Steve Tweed: Hatchery Specialist, Cobb World Technical Support Team. The importance of good ventilation is taken for granted on the farm but it doesn t always attract

More information

B. Assemble the Method-25 sample train with a heated probe/filter.

B. Assemble the Method-25 sample train with a heated probe/filter. 6/30/2015 VOC Reporting, Inc. Method 25 Heated Controller Operating Instructions. pg. 1 of 5 INSTRUCTIONS FOR EPA METHOD-25 FIELD SAMPLE COLLECTION USING A VRi HEATED PROBE AND FILTER ASSEMBLY Introduction:

More information

MARATHON SENSORS INC. TROUBLESHOOTING A CARBON PROBE

MARATHON SENSORS INC. TROUBLESHOOTING A CARBON PROBE When there is a problem making consistent product in a carborizing furnace you must consider all the possibilities before replacing the oxygen sensor. In many cases using the sensor and the control instrument

More information

To save this document, scroll up and select the download icon

To save this document, scroll up and select the download icon Thank you for purchasing a RustySpokes Softcruise. We know you are going to enjoy the bike, but if you had it shipped to you, there are a few things you need to do to assemble the bike. The seat, pedals

More information

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide ABB MEASUREMENT & ANALYTICS PRODUCT GUIDE PG/SMD140 EN REV. B UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide Measurement made easy UKAS calibration laboratory

More information

Cleaning rod: spring steel, stainless steel or carbon fibre cleaning rod - only use a one-piece rod. Avoid using snakes.

Cleaning rod: spring steel, stainless steel or carbon fibre cleaning rod - only use a one-piece rod. Avoid using snakes. Telemark Biathlon Where performance and precision come together http://telemarkbiathlon.com Rifle Cleaning Date : July 19, 2013 Anschutz Rifle Manual - Click Here Izhmash 7-3 Rifle Manual - still looking

More information

Sideshift SS230 Installation on a 2006 Bayliner 265SB

Sideshift SS230 Installation on a 2006 Bayliner 265SB The Sideshift SS230 was packaged very well and all parts were clearly labelled and documented. The overall quality seems far more durable than I expected... I was somewhat concerned that the unit may become

More information

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F29, F30, F31, F32 & F33

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F29, F30, F31, F32 & F33 INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F29, F30, F31, F32 & F33 FOR TWO-STAGE 90 PLUS DOWNFLOW/HORIZONTAL (-GTK) MODELS Recognize this symbol as an indication of Important Safety Information

More information

5 Channel Calibrator

5 Channel Calibrator 212 N. Woodwork Lane Palatine, IL 60067 800-223-3977 5 Channel Calibrator Part # 0724 User Manual Questions? Contact us at 800-223-3977 or online at http://www.cleanair.com/equipment/express/main.html

More information

LRS(H)4 Pressure-Reducing Regulator User Manual

LRS(H)4 Pressure-Reducing Regulator User Manual LRS(H)4 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be considered

More information

Pure Water Power Purification System 4-Stage RODI Operations Manual

Pure Water Power Purification System 4-Stage RODI Operations Manual Pure Water Power Purification System 4-Stage RODI Operations Manual Flush Valve Lever Quick Disconnect for RO Water Testing Water Supply In Drain Hose Pure Water Out to Waterfed Pole New Machine Setup

More information

DPC-30 DPC-100. Reference Manual

DPC-30 DPC-100. Reference Manual DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,

More information

Eurostyle Terminal Blocks Focus Product Stock List

Eurostyle Terminal Blocks Focus Product Stock List Eurostyle Terminal Blocks Focus Product Stock List Introduction Table of Contents In an ongoing effort to better serve the Industrial Machinery, Commercial, and HVAC markets, Tyco Electronics is pleased

More information

Postal Service Practice Exam Sample Exam # 5 Exam # 955E

Postal Service Practice Exam Sample Exam # 5 Exam # 955E Postal Service Practice Exam Sample Exam # 5 Exam # 955E Copyright 2017 All rights reserved Customer Support: support@postaljobssourcewcs.com About Exam 955E This exam is only used for a few positions,

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration 4 Digit Display, 4-20mA Output Instruction Manual (Digital Differential Pressure Transmitter) 1. General Specification 2. Installation 3. Wiring 4. Function 5. Setting & Calibration 1 4 20 1 Differential

More information

Digital Melting Point Apparatus

Digital Melting Point Apparatus Digital Melting Point Apparatus Heating Plateau Ramping Start/Stop Plateau set Ramp stop Hold User Guide Version 1.1 Heating Viewing tube Sample Chamber IEC power inlet socket Power on/off Temperature

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for the installation, operation, and

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021-PR Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-PR For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4

More information

Installation Instructions

Installation Instructions LP and High Altitude LP Gas Conversion Kit For United States Installations Installation Instructions For Model Series *G6/PGF1 Furnaces, *L1/PGC1 Furnaces, and *R4/PPG1 Gas/Electric Appliances using Honeywell

More information

Datasheet: K-30 ASCII Sensor

Datasheet: K-30 ASCII Sensor Datasheet: K-30 ASCII Sensor The K30 ASCII sensor is a low cost, infrared and maintenance free transmitter module intended to be built into different host devices that require CO2 monitoring data. The

More information

Bearhawk #164 Three Sigma Checkout Report. Date: Mar 08. Objectives:

Bearhawk #164 Three Sigma Checkout Report. Date: Mar 08. Objectives: Bearhawk #164 Three Sigma Checkout Report Date: 21-23 Mar 08 Objectives: 1. Stop fuel seep around plug in top of gascolator 2. Remove fuel selector handle and remaining floor 3. Pitot-static leak check

More information

GV Standard X-Vent. Setup, Commissioning & Installation Guide

GV Standard X-Vent. Setup, Commissioning & Installation Guide GV Standard X-Vent Setup, Commissioning & Installation Guide Technical experts in the design, manufacture and supply of precision engineered, architectural rooflights for residential and commercial buildings.

More information

Symptom: The basic symptom is your sail will not roll in or out without force. The drum unit is hard to turn. Your sail will not roll out on its own.

Symptom: The basic symptom is your sail will not roll in or out without force. The drum unit is hard to turn. Your sail will not roll out on its own. Schaefer 2100 roller furler drum replacement on Catalina 320 Danny Jensen, A BOA VIDA hull #972, Thanks to contributions Chris Burti, Jeff Hare and C320 group for comments Photos were taken and edited

More information

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50 Rev.02 (2014.06) OL Page 1 of 8 Table of contents I. STRUCTURE OF THE MANUAL / CLARIFICATION... 3 II. SAFETY AND HEALTH CONCERNS... 4 1 INTRODUCTION... 5 1.1 Use

More information

K V A L I F I K. Our accreditation number: NAH /2015. Valid to:

K V A L I F I K. Our accreditation number: NAH /2015. Valid to: KVALIFIK Ltd. has founded in 1991. In 1993 our calibration laboratory has get the accredited status and we have calibrated standards for the generally used physical parameters. Our standards are traceable

More information

FILTER TYPE PRESSURE SNUBBER

FILTER TYPE PRESSURE SNUBBER FILTER TYPE PRESSURE SNUBBER Pressure oscillations and other sudden pressure changes can affect the delicate mechanisms of a pressure gauge or pressure transmitter. This can result in either complete failure

More information

Table of Contents Documentation for PIT TROLLEY A4

Table of Contents Documentation for PIT TROLLEY A4 Table of Contents Documentation for PIT TROLLEY A4 Declaration of conformity 1 Safety instructions and routines to check for safety 2 Description of features and technical data 3 Assembly instructions

More information

Schaefer recognized this issue and they offer to replace the drum bearing assembly for $

Schaefer recognized this issue and they offer to replace the drum bearing assembly for $ Schaefer 2100 roller furler drum replacement on Catalina 320 Danny Jensen, A BOA VIDA hull #972, Thanks to contributions Chris Burti, Jeff Hare and C320 group for comments Photos were taken and edited

More information

Mate ULTRA IMT Multi Tool Assembly Tooling Installation Instructions

Mate ULTRA IMT Multi Tool Assembly Tooling Installation Instructions Installation and assembly instructions for Mate ULTRA IMT Multi Tool Punch and Die Holder assemblies. 8-Station is shown. 3-Station uses the same procedure. Lubrication Port Keep top lubricated (for machine

More information

Operating Instructions Part No

Operating Instructions Part No DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0545 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service

More information

A4s Operation Manual

A4s Operation Manual A4s Operation Manual Safety Instruction Please read this manual carefully, also with related manual for the machinery before use the controller. For installing and operating the controller properly and

More information

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F13, RXGY-F27 AND RXGY-F28

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F13, RXGY-F27 AND RXGY-F28 INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F13, RXGY-F27 AND RXGY-F28 FOR TWO-STAGE (GPL/GPR/GPE/GLL/GLR/GLE) MODELS Recognize this symbol as an indication of Important Safety Information THESE

More information

! Warning, refer to accompanying documents.

! Warning, refer to accompanying documents. About this Manual To the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures accurate and adequate to operate this instrument

More information

Operating Instructions Part No

Operating Instructions Part No DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0578 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service

More information

CSA Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual 30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

Safe Work Instructions For Oxygen Acetylene Equipment

Safe Work Instructions For Oxygen Acetylene Equipment Safe Work Instructions For Oxygen Acetylene Equipment Policy Sponsor: Assistant Vice President Facilities Management Responsible Unit: Trade Services Approval Date: September 2010 Revisions: January 2018

More information

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer July 2011 OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer WARNING! Before operating this product, read and understand this Operator s Manual. Become familiar with the potential hazards of this unit. Contact

More information

Met One E-BAM Particulate Monitor

Met One E-BAM Particulate Monitor STANDARD OPERATING PROCEDURES Met One E-BAM Particulate Monitor AMBIENT AIR MONITORING PROGRAM for the 130 LIBERTY STREET DECONSTRUCTION PROJECT LOWER MANHATTAN DEVELOPMENT CORPORATION 1 Liberty Plaza

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.

More information

Model 130M Pneumatic Controller

Model 130M Pneumatic Controller Instruction MI 017-450 May 1978 Model 130M Pneumatic Controller Installation and Operation Manual Control Unit Controller Model 130M Controller is a pneumatic, shelf-mounted instrument with a separate

More information

MODEL 269DF-LCF-LCF/WS FILLING SYSTEM

MODEL 269DF-LCF-LCF/WS FILLING SYSTEM MODEL 269DF-LCF-LCF/WS FILLING SYSTEM 29975 Parkway Roseville, Michigan 48066 (586) 778-0426 Fax (586) 778-0479 www.gordinier.com Email: pat@gordinier.com MODEL 269DF-LCF-LCF/WS TABLE OF CONTENTS Receiving

More information

LNVx Gas Conversion Kit Instructions

LNVx Gas Conversion Kit Instructions TB134 Issue 1.0 Nov 2018 Applies to models: LNVx LNVx Gas Conversion Kit Instructions +44 (0) 1460 53535 info@powrmatic.co.uk www.powrmatic.co.uk General Information Heater conversion between gases will

More information

RD(H)20/25 Pressure-Reducing Regulator User Manual

RD(H)20/25 Pressure-Reducing Regulator User Manual RD(H)20/25 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be

More information

BIOPAK 240R MAINTENANCE TOOL KIT. TOOL KIT PART NUMBER: B Revision A

BIOPAK 240R MAINTENANCE TOOL KIT. TOOL KIT PART NUMBER: B Revision A BIOPAK 240R MAINTENANCE TOOL KIT User Manual TOOL KIT PART NUMBER: B6 02 5003 79 0 Revision A Contents Subject Page About the Maintenance Tool Kit 1 Description of the Maintenance Tool Kit 2 Various Test

More information

Preliminary filter Precision measurement chamber Flow meter Instruction manual

Preliminary filter Precision measurement chamber Flow meter Instruction manual Preliminary filter 0554 3311 Precision measurement chamber 0554 3312 Flow meter 0554 3313 Instruction manual en 2 Safety and the environment Safety and the environment About this document Please read this

More information

Fiber Cable Puller with Tuf-Lugger lite

Fiber Cable Puller with Tuf-Lugger lite 7 OPERATING INSTRUCTION MANUAL Fiber Cable Puller with Tuf-Lugger lite Copyright 2015 DCD Design & Manufacturing Ltd. Revision 1.0 IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING The Fiber

More information

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A 2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A PROJECT ADDRESS TESTING AUTHORITY TELEPHONE Checked by/date Enforcement Agency Use GENERAL INFORMATION OF BLDG. PERMIT PERMIT # BLDG. CONDITIONED FLOOR

More information

INSTALLATION & OPERATION MANUAL. Dual Duct VAV Terminals. Redefine your comfort zone.

INSTALLATION & OPERATION MANUAL. Dual Duct VAV Terminals. Redefine your comfort zone. INSTALLATION & OPERATION MANUAL Dual Duct VAV Terminals IOM Dual Duct VAV Terminals IMPORTANT! READ BEFORE PROCEEDING! GENERAL SAFETY GUIDELINES This equipment is a relatively complicated apparatus. During

More information

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM

More information

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235) P/N 126905-01 Rev. B 11/2016 INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235) For All Single, Dual and Triple Burner Natural and Propane/LP Gas Logs P126905-01 For

More information

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual Air Bubbler Depth Gauge DG2200 Installation and Reference Manual Rev. 3.2.2 06/2011 Installation and Reference Manual Page 2 Contents Chapter 1: Installation and Overview... 3 1.1 DG2200 Location Diagram...

More information

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F23, F24, F25, F26, F38, F39, F40 & F41

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F23, F24, F25, F26, F38, F39, F40 & F41 INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F23, F24, F25, F26, F38, F39, F40 & F41 FOR MODULATING DOWNFLOW/HORIZONTAL AND DEDICATED HORIZONTAL MODELS (-GGD, -GGE, -GGF)! Recognize this symbol

More information

Final Assembly Instructions Bikes with Threaded Headsets

Final Assembly Instructions Bikes with Threaded Headsets Final Assembly Instructions Bikes with Threaded Headsets Thank you for buying your new bicycle from L.L.Bean. Read these instructions carefully before beginning the final assembly. Prior to shipping, our

More information

GEN-1e CO2 Generator OVERVIEW INSTALLATION PROPANE GENERATORS ONLY NATURAL GAS GENERATORS ONLY

GEN-1e CO2 Generator OVERVIEW INSTALLATION PROPANE GENERATORS ONLY NATURAL GAS GENERATORS ONLY GEN-1e CO2 Generator Custom Automated Products offers economical and safe carbon dioxide generators. They produce CO2 by burning either propane or natural gas. We have designed our CO2 generator to allow

More information

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission

More information

RAM Operation Manual

RAM Operation Manual RAM 4021-1 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-1 For Your Safety... 2 Description... 2 Setup Mode... 3 Lights/Alarms... 3 Operation... 4 Calibration...

More information

In Vivo Scientific, LLC INSTRUCTION MANUAL

In Vivo Scientific, LLC INSTRUCTION MANUAL CO 2 Controller In Vivo Scientific, LLC INSTRUCTION MANUAL CONTENTS CONTENTS...1 ABOUT THIS MANUAL...2 INTRODUCTION...2 Cautions and Warnings...2 Parts List...2 Unpacking...2 INSTRUMENT DESCRIPTION...3

More information

Improving distillation tower operation

Improving distillation tower operation Improving distillation tower operation Measuring differential pressure across long sections of distillation columns has always been challenging, but purpose-built sensor systems provide a solution Fast

More information

I N N O V A T I O N C O N T I N U E S... International Patent Filed in 45 Leading Countries

I N N O V A T I O N C O N T I N U E S... International Patent Filed in 45 Leading Countries I N N O V A T I O N C O N T I N U E S... Quick Check International Patent Filed in 45 Leading Countries World's First Single Piece Multi-Function Check Standard for Calibration or Verification of Various

More information

H.T.S.T. EQUIPMENT TEST PROCEDURES. Field Reference. Sequence of Testing. Pasteurizer Not Operating 3, 1, 4, 2, 7, 10, 8, 5B, 5E, 5C (dual stem), 9

H.T.S.T. EQUIPMENT TEST PROCEDURES. Field Reference. Sequence of Testing. Pasteurizer Not Operating 3, 1, 4, 2, 7, 10, 8, 5B, 5E, 5C (dual stem), 9 H.T.S.T. EQUIPMENT TEST PROCEDURES Field Reference Sequence of Testing Equipment testing should be conducted in the following sequence to minimize equipment run times. Pasteurizer Not Operating 3, 1, 4,

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION Models No. TD0101, TD0101F Description Impact Driver L PRODUCT P 1/ 14 CONCEPT AND MAIN APPLICATIONS Models TD0101 and TD0101F are cost-competitive 100N.m-class impact driver developed

More information

RPS900W Redundant Power Supply. Installation Guide.

RPS900W Redundant Power Supply. Installation Guide. RPS900W Redundant Power Supply Installation Guide www.edge-core.com Installation Guide RPS900W Redundant Power Supply Single DC Output Port with Dual Output Voltages RPS900W E10013-CS-R01 1500000081A

More information

Air Ball! Evaluation copy

Air Ball! Evaluation copy Air Ball! Computer 24 Do you ever wonder how the National Basketball Association (NBA) decides how much air should be in the basketballs used during a game? The NBA measures the pressure inside the ball

More information

CONTEST DESCRIPTION / DESCRIPTION DE CONCOURS SHEET METAL WORK TÔLERIE POST- SECONDARY / NIVEAUX POSTSECONDAIRE

CONTEST DESCRIPTION / DESCRIPTION DE CONCOURS SHEET METAL WORK TÔLERIE POST- SECONDARY / NIVEAUX POSTSECONDAIRE CONTEST DESCRIPTION / DESCRIPTION DE CONCOURS SHEET METAL WORK TÔLERIE POST- SECONDARY / NIVEAUX POSTSECONDAIRE Table of Contents 1 THE ESSENTIAL SKILLS FOR CAREERS IN THE SKILLED TRADES AND TECHNOLOGY...

More information

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition Depth sensor Product reference : 90-60-456 REV 1 USER GUIDE and INSTALLATION GUIDE nke Sailing competition Z.I. Kerandré Rue Gutenberg 56700 HENNEBONT- FRANCE http://www.nke.fr After sale service n 33

More information

5 Function Indicator. Outside Air Temperature (C) Outside Air Temperature (F) Pressure Altitude Density Altitude Aircraft Voltage STD TEMP SL 15000

5 Function Indicator. Outside Air Temperature (C) Outside Air Temperature (F) Pressure Altitude Density Altitude Aircraft Voltage STD TEMP SL 15000 5 Function Indicator +20 +40-5000 STD TEMP SL 15000 Outside Air Temperature (C) Outside Air Temperature (F) Pressure Altitude Density Altitude Aircraft Voltage 427 HILLCREST WAY REDWOOD CITY, CA 94062

More information

www.myrower.com support@myrower.com ASSEMBLY Congratulations on purchasing the MyRower! Please see the following pages for instructions on assembling your MyRower. Bits bag contents: Rail Cross Bolt (90mm)

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Probe Instrument Regulator Model The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for

More information

Model: 43T. Bermad Pressure Relief Valve

Model: 43T. Bermad Pressure Relief Valve Model: 43T Bermad Pressure Relief Valve Installation Operation Maintenance Manual () Rev.C1_01.08.17 Page 1 of 10 Safety First BERMAD believes that the safety of personnel working with and around our equipment

More information

ACV-10 Automatic Control Valve

ACV-10 Automatic Control Valve ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,

More information

ANNOUNCEMENT. Panther/Cougar Series SCBA Technician Training is a two day class

ANNOUNCEMENT. Panther/Cougar Series SCBA Technician Training is a two day class ANNOUNCEMENT Sperian Respiratory Protection USA, LLC, a Company is pleased to announce our next SCBA regulator repair/maintenance training class to be held in Pembroke Pines, Florida on February 7 th,

More information

HEAVY-DUTY AIR RATCHET WRENCH OWNER S MANUAL

HEAVY-DUTY AIR RATCHET WRENCH OWNER S MANUAL HEAVY-DUTY AIR RATCHET WRENCH OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Final Assembly Instructions Bikes with 16 Wheel Size

Final Assembly Instructions Bikes with 16 Wheel Size Final Assembly Instructions Bikes with 16 Wheel Size Thank you for buying your new bicycle from L.L.Bean. Read these instructions carefully before beginning the final assembly. Prior to shipping, our expert

More information

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator. LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the

More information

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante810 Benchtop Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante810 benchtop dissolved oxygen

More information

ECE 477 Digital Systems Senior Design Project Rev 9/12. User Manual

ECE 477 Digital Systems Senior Design Project Rev 9/12. User Manual User Manual Year: 2014 Semester: Fall Team: 7 Project: Digital Knockout Creation Date: November 17, 2014 Last Modified: October 7, 2015 Author: Email: rdacted@purdue.edu Assignment Evaluation:

More information