2.07 Amperometric Sensors

Size: px
Start display at page:

Download "2.07 Amperometric Sensors"

Transcription

1 Chlorine Sensor Type CC 1 Measurement of free, organic cyanuric acid chlorine ; reduced dependence to ph-level Type CC 1 utomatic, with integrated NTC resistor Restricted concentration of surfactants allowed. Organic based cyanuric acid chlorine ppm ph Range: ph 4 12 Membrane Cap: M48 Electrolyte: ECC ml Chlorine Sensor Type CC 1 HUn mv/ppm N mv/ppm ±5 to ±15 Un mv/ppm M m pin terminal (Type CC 1-M only) M 2 3 (Example for order code) 9 Technical and commercial modification and misprints reserved V12/06

2 mperometric Sensor Type DOSSens DCL10 for the registration of free, inorganic chlorine, at stable ph-level Special Performance Features: The DOSSens DCL10-Sensor for the of free, inorganic chlorine is a logical follow -up development of membrane-covered sensors. This type of sensors are already approved in disinfection control of potable water and swimming-pool applications over many years. The brand new features of the DOSSens DCL10-Sensors are focused in the practical functionality. pproved electro-chemical meats recent microprocessor technology and produces new synergies and advantages facing the existing sensors on market: Microprocessor-control integrated in sensor-shaft for the output of the sensor signal, already temperature compensated Different signal outputs are realized in only one system: - Current output 4 20 m - Voltage output mv - Serial Interface RS 485 The serial interface provides the following inform ation to a connected controlling system: - Chlorine value, already temperature compensated - Temperature - Operation hour counter - ID-Code and the capability for the connection of several sensors in the same communication system - dd. OEM-specific information, as failure memory, incl. time-stamp for the last 6 faults (e.g. strong osci l- lating values, oscillating power-supply etc.) In addition the DOSSens DCL10-Sensor provides a ma g- nificent new feature: Two LED s placed in the sensor-shaft are showing the actual sensor performance: Green (luminous): - The sensor is working proper - The sensor is detecting chlorine and the chlorine concentration is within the sensor measuring range. Red (luminous): - The detected chlorine concentration is lower or nearby the lower measuring range. The signaloutput is set to 0 m (mv) to block a sensor calibration. Either green nor red : - No power supply. V12/06 Technical and commercial modification and misprints reserved 2

3 mperometric Sensor Type DOSSens DCL10 for the registration of free, inorganic chlorine, at stable ph-level DOSSens DCL10 : Measured variable: Measuring range*: Signal output: Polarisation time: First polarization Subsequent Response time: Upwards Downwards Drift: Max. counter- Passive-operated, membrane-covered, amperometric two-electrode system Chlorine in drinking, swimming pool-, process-, or industrial water and water of similar quality. Surfactants are not allowed. Stable ph level is required. Free, inorganic chlorine Sodium hypochlorite Calcium hypochlorite ppm ppm ppm ppm - Serial Interface RS Current output 4 20 m, or - Voltage output mv approx. 60 min approx. 30 min 90% < 2 min, 99% < 5 min 90% < 0,5 min, 99% < 3 min < 1.5% per month 1.0 bar ph Range: ph Min. flow rate**: Min. flow velocity: Electrical connection: 0-2V version: 4 20 m version: Protection category Shaft material: Dimension: 15 cm/s 0-2V version: VDC 4 20 m version: 24 VDC 6 pin snap-on connector with interlocking 3 pin snap-on connector with interlocking IP 67 in fixed condition PVC Diameter approx.: Length approx: 25 mm 175 mm * The measuring range depends to the selected output signal. ** For a proper process installation the DOSFlow in-line probe housings are recommended. 3 Technical and commercial modification and misprints reserved V12/06

4 Chlorine Sensor Type CP 2.1 Measurement of total chlorine (= free and bounded chlorine), inorganic and organic (cyanuric acid chlorine); reduced dependence to ph-level Type CP 2.1 utomatic, with integrated NTC resistor Surfactants, fat and oil are not allowed. Sodium -hypochloride (NaOCl), Calcium -hypochloride(ca(ocl)2), electrolytic generated chlorine, chlorine gas and organic based cyanuric acid chlorine ppm ph Range: ph 4 12 Membrane Cap: M48 Electrolyte: ECP 1 Gel 100 ml Chlorine Sensor Type CP 2.1 HUn mv/ppm N mv/ppm ±5 to ±15 M m pin terminal (Type CP 2.1-M only) M 2 3 (Example for order code) V12/06 Technical and commercial modification and misprints reserved 8

5 Chlorine Sensor Type CS 2.3 Measurement of free, inorganic chl orine; reduced dependence to ph-level Type CS 2.3 utomatic, with integrated NTC resistor Surfactants, fat and oil are not allowed. Sodium -hypochlorite (NaOCl), Calcium -hypochlorite(ca(ocl)2), Electrolytic generated chlorine, Chlorine gas 0,005 10,00 ppm ph Range: ph 4 11 Membrane Cap: M48G Electrolyte: ECS 1 Gel 100 ml Chlorine Sensor Type CS 2.3 HUn mv/ppm N mv/ppm ±5 to ±15 M m pin terminal (Type CS 2.3-M only) M 2 3 (Example for order code) 7 Technical and commercial modification and misprints reserved V12/06

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly Technical Information CCS240 and CCS241 Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Chlorine dioxide is used for disinfection

More information

swimming pool technology

swimming pool technology 68 swimming pool technology 69 Measuring and control equipment Measuring, control and dosing systems for private swimming pools Systematic water care: Swim-tec dosing systems are responsible for controlling

More information

Ozone. Sensoric O3 3E 1

Ozone. Sensoric O3 3E 1 Ozone Sensoric O3 3E 1 1 FEATURES Amperometric 3 electrode sensor cell Long life time High reliability High resolution Fast response time Fixed organic gel electrolyte TYPICAL APPLICATIONS Environmental

More information

Sensoric 4-20 ma Transmitter Board Operation Manual

Sensoric 4-20 ma Transmitter Board Operation Manual Sensoric 4-20 ma Transmitter Board Operation Manual 1 Content Features Operation Manual Technical Data Mechanical Dimensions Remarks & Contact information 2 Features Soldered sensor cell (non replaceable)

More information

STERILIZABLE DISSOLVED OXYGEN SENSORS

STERILIZABLE DISSOLVED OXYGEN SENSORS STERILIZABLE DISSOLVED OXYGEN SENSORS USER MANUAL Table of Contents 1. Introduction 2. Operation 3. Calibration 4. Electrode Verification 5. Mounting 6. Maintenance 7. Storage 8. Instructions for Exchange

More information

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument OxyScan Graphic Operating Instructions UMS Micro-oxygen sensor 501 Microprocessor instrument Introduction Thank you for choosing the UMS Micro Oxygen Sensor 501 - a highly advanced product! Please read

More information

Datasheet: K-30 ASCII Sensor

Datasheet: K-30 ASCII Sensor Datasheet: K-30 ASCII Sensor The K30 ASCII sensor is a low cost, infrared and maintenance free transmitter module intended to be built into different host devices that require CO2 monitoring data. The

More information

Non-Membrane Disinfection Sensors Instruction Manual

Non-Membrane Disinfection Sensors Instruction Manual W A L C H E M IWAKI America Inc. Disinfection Sensors Non-Membrane Disinfection Sensors Instruction Manual Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA TEL: 508-429-1110 WEB: www.walchem.com

More information

Walchem Disinfection Sensors WCDB, WFCB, WOZB and WPAB Instruction Manual

Walchem Disinfection Sensors WCDB, WFCB, WOZB and WPAB Instruction Manual W A L C H E M An Iwaki America Company Disinfection Sensors Walchem Disinfection Sensors WCDB, WFCB, WOZB and WPAB Instruction Manual Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA TEL: 508-429-1110

More information

SCL SCL 11 SCL2 SCL 9 SCL 10 SCL 3/S SCL 3/N SCL 8 SBR SCT OPERATING MANUAL CLOSED AMPEROMETRIC CELLS

SCL SCL 11 SCL2 SCL 9 SCL 10 SCL 3/S SCL 3/N SCL 8 SBR SCT OPERATING MANUAL CLOSED AMPEROMETRIC CELLS SCL EN SCL 3/S SCL 3/N SCL 8 SBR SCT SCL2 SCL 9 SCL 10 CLOSED AMPEROMETRIC CELLS SCL 11 OPERATING MANUAL GENERAL SAFETY GUIDELINES...3 PURPOSE OF USE AND SAFETY...4 ENVIRONMENTAL SAFETY...5 LABELS...5

More information

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump Page 1 of 6 TPS Australia - Quality hand-made instruments since 1968. Nothing's as cool, as a freshwater pool easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump Automatic

More information

GasSense NDIR User Manual

GasSense NDIR User Manual INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION

More information

Heavy Duty Dissolved Oxygen Meter

Heavy Duty Dissolved Oxygen Meter User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 FAX 781.665.0780 - TestEquipmentDepot.com Introduction Congratulations

More information

Series 4000 Transmitter Analyzer Controller. Series CL4000 Chlorine Probes used with MicroChem 2

Series 4000 Transmitter Analyzer Controller. Series CL4000 Chlorine Probes used with MicroChem 2 www.severntrentservices.com MicroChem 2 Series 4000 Series 4000 Transmitter Analyzer Controller Series CL4000 Chlorine Probes used with MicroChem 2 Series 4000 Transmitter and CL4000 Bufferless Probe Series

More information

Phosgene Sensor. Sensoric COCl2 3E 1

Phosgene Sensor. Sensoric COCl2 3E 1 Phosgene Sensor 1 FEATURES Amperometric 3 electrode sensor cell Fixed organic electrolyte High reliability TYPICAL APPLICATIONS Ambient monitoring of TLV levels Chemical Industry, Homeland Security PART

More information

Operating Instructions CCS120. Sensor for total chlorine. BA388C/07/en/

Operating Instructions CCS120. Sensor for total chlorine. BA388C/07/en/ Operating Instructions CCS120 Sensor for total chlorine BA388C/07/en/07.06 51517372 Brief overview Here is how to use these Operating Instructions to commission your sensor quickly and safely: Safety instructions

More information

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)

More information

Dosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &

Dosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing & C hemical Dosing & Controllers Granudos Chemical Dosing & Controllers Controllers Chemical Storage Granudos Granudos 10-CPR Touch Granudos 10-CPR Touch swimming pool disinfection system using IQ Granu-Chlor

More information

Jacuzzi. J-SS40 Salt System Installation and Operating Instructions

Jacuzzi. J-SS40 Salt System Installation and Operating Instructions Jacuzzi J-SS40 Salt System Installation and Operating Instructions IMPORTANT SAFETY INSTRUCTIONS WARNING: Before installing this product. Read and follow all warning notices and instructions accompanying

More information

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications Technical Information Oxymax W COS41 Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications Application The continuous measurement of the dissolved

More information

11. Aquasalt. Aquasalt Aquasalt 440. Salt electrolysis demonstration 442. Spare parts and Accessories 443. Chemical Products

11. Aquasalt. Aquasalt Aquasalt 440. Salt electrolysis demonstration 442. Spare parts and Accessories 443. Chemical Products . 434. 440. Salt electrolysis demonstration 442. Spare parts and Accessories 443. Chemical Products 432 433 Pleasure and benefits for our health removes the unpleasant smell from chlorine in your swimming

More information

Your Bonus. Steps for doing the Homework. Make sure you convert to the correct units of measure:

Your Bonus. Steps for doing the Homework. Make sure you convert to the correct units of measure: Your Bonus Steps for doing the Homework 1. Read the entire question. 2. Read it again: understand what it is asking. 3. Apply the appropriate formula (from page 5 of the Handout Packet). 4. Write the formula

More information

E N G L I S H. Please carefully read this operating instructions completely before commissioning the probe! Do not discard!

E N G L I S H. Please carefully read this operating instructions completely before commissioning the probe! Do not discard! October 2015 E N G L I S H Please carefully read this operating instructions completely before commissioning the probe! Do not discard! The operator shall be liable for any damage caused by installation

More information

Swell UK. The UK's leading online aquatic retailer.

Swell UK. The UK's leading online aquatic retailer. Swell UK The UK's leading online aquatic retailer www.swelluk.com - Operation Manual ph - Computer With the purchase of this digital measuring and control equipment you have selected a top quality product.

More information

CHAPTER 5 WATER QUALITY, TEST KITS, RECORD KEEPING

CHAPTER 5 WATER QUALITY, TEST KITS, RECORD KEEPING CHAPTER 5 WATER QUALITY, TEST KITS, RECORD KEEPING Section 1. Water Quality. (a) The water quality for pools, spas and similar installations shall meet the criteria outlined in the following charts: Sanitizing

More information

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

COM280. Technical Information. Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement

COM280. Technical Information. Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement Technical Information COM280 Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement Application COM280 is a pocket meter for measuring dissolved oxygen. It is suitable for the

More information

Pool and Spa. Water Testing

Pool and Spa. Water Testing Pool and Spa Water Testing Pocket Digital Testers for Pools HI-701 Checker: Free Chlorine Hand-held Colorimeter The HI-701 is a simple, accurate and cost effective way to measure free chlorine. Free Chlorine:

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

O3 3E 1 F Gas Sensor Module

O3 3E 1 F Gas Sensor Module Product Information Pack O3 3E 1 F Gas Sensor Module (Ozone) CONTENTS Product Data Sheet Product Specification 2 Poisoning and Cross Sensitivities 3 Operating Instructions Introduction 4 Electrostatic

More information

Membrane covered optical CO 2 sensor

Membrane covered optical CO 2 sensor Membrane covered optical CO 2 sensor - Manual - 30 mg/l CO 2, 4-20 ma output Exclusively Distributed & Supported By: www.edaphic.com.au info@edaphic.com.au Ph: 1300 430 928 Warning! Do never try to unscrew

More information

SENSORS Pressure CALDARO

SENSORS Pressure CALDARO SENSORS Standards Specials THE MMI & MMF SPECIALIST The Caldaro Way From the very beginning Caldaro has managed to establish itself as a highly reputable OEM supplier of tailored controller and sensor

More information

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Oxygen Measurement Systems High Reliability and Wide Application Coverage Introduction High Process Efficiency Under Any Condition Oxygen Measurement Systems High Reliability and Wide Application Coverage METTLER TOLEDO provides sensors to measure dissolved oxygen (DO) in demanding

More information

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range: The ECO-Sure X is a long life, high quality, cost effective 2-electrode electromechanical cell designed for the detection of Carbon Monoxide CO in a range of applications but particularly for domestic/residential

More information

Instruction and Maintenance Manual

Instruction and Maintenance Manual Instruction and Maintenance Manual GRYF OXY ZM 02/100/2 E Contact GRYF HB, spol. s r.o. Cechova 314 Havlickuv Brod 580 01 tel.: +420 569 426 627 fax: +420 569 426 627 www.gryf.eu ver.: 11.2.2015 OEM module

More information

Instruction Manual MicroChem 2 Chlorine Probes Series CL4000

Instruction Manual MicroChem 2 Chlorine Probes Series CL4000 Instruction Manual MicroChem 2 Chlorine Probes Series CL4000-1 - 210.6405.15 These instructions describe the installation, operation and maintenance of the subject equipment. Failure to strictly follow

More information

Precision pressure sensor Basic version Model CPT6020

Precision pressure sensor Basic version Model CPT6020 Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications

More information

All Sixth Sense cells for toxic gas detection are based on electrochemical principles and can be classified as amperometric fuel cells.

All Sixth Sense cells for toxic gas detection are based on electrochemical principles and can be classified as amperometric fuel cells. 1.1 Two or Three Electrodes? All Sixth Sense cells for toxic gas detection are based on electrochemical principles and can be classified as amperometric fuel cells. The simplest form of electrochemical

More information

UsER manual for Watersens ph -REDOX

UsER manual for Watersens ph -REDOX UsER manual for Watersens -REDOX Cl 8 1 2 6 3 3 7 7 4 4 4 4 Parts List 1 Redox Probe 1 x 2 PH Probe 1 x 5 Tube Weight 2 x 6 Connection Valve 1 x chlorine 3 Chlorine and Pumps 2 x 7 Dosing Valve 2 x 5 5

More information

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES PROCESS ANALYSERS DF-310E The DF-310E is a Coulometric sensor based oxygen analyzer designed to measure trace and percent level oxygen in pure and multi-gas backgrounds for process and quality control

More information

DULCOTEST Sensor CGE, Type: CGE 3-mA-2 ppm; CGE 3-mA-10 ppm

DULCOTEST Sensor CGE, Type: CGE 3-mA-2 ppm; CGE 3-mA-10 ppm Assembly and operating instructions DULCOTEST Sensor CGE, Type: CGE 3-mA-2 ppm; CGE 3-mA-10 ppm EN A1953 Please carefully read these operating instructions before use! Do not discard! The operator shall

More information

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving Technical Information Oxymax H COS21 Sensor with long-term stability for frequent sterilization and autoclaving Application Process control in enzyme production Control of culture growth Biotechnological

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Operating manual. TA 197 Oxi. Dissolved Oxygen Depth Armature

Operating manual. TA 197 Oxi. Dissolved Oxygen Depth Armature Operating manual Dissolved Oxygen Depth Armature ba25302e05 04/2009 Copyright Weilheim 2009, WTW GmbH Reprinting - even as excerpts - is only allowed with the explicit written authorization of WTW GmbH,

More information

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS Electronic pressure switches ATM/GR CUSTOMER BENEFITS Pressure sensor with integrated switching contacts Modular sensor structure (any process and electrical connections can be combined) Manual readjustment

More information

Technical Data Sheet MF010-O-LC

Technical Data Sheet MF010-O-LC Technical Data Sheet MF010-O-LC - 1 - 1. Properties The oxygen measuring system MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 C. It is particularly suitable for the

More information

Flow metering in gases Introduction to COMBIMASS family

Flow metering in gases Introduction to COMBIMASS family Flow metering in gases Introduction to COMBIMASS family - physical principle, basic information - different types of instruments, pricing & delivery time Sales Training Germany October 17 th to 19 th,

More information

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Bante820 Portable Dissolved Oxygen Meter Instruction Manual Bante820 Portable Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante820 Portable Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante820 portable dissolved oxygen

More information

Optical Dissolved Oxygen Meter

Optical Dissolved Oxygen Meter Optical Dissolved Oxygen Meter HI764113 Rugged Optical Dissolved Oxygen Probe for Fresh and Saltwater Applications Digital, weighted probe No membranes No electrolytes No oxygen consumption No flow dependence

More information

better measurement Simply a question of

better measurement Simply a question of Simply a question of better measurement SCHMIDT Flow Sensor SS 20.600 The powerful industrial professional for demanding applications involving air and gases. Industrial processes Pneumatic technology

More information

Instruction and Maintenance Manual

Instruction and Maintenance Manual Instruction and Maintenance Manual GRYF OXY Z 02/100/2 E Contact GRYF HB, spol. s r.o. Cechova 314 Havlickuv Brod 580 01 tel.: +420 569 426 627 fax: +420 569 426 627 Czech Republic www.gryf.eu Technical

More information

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter INSTRUCTION MANUAL Loop Powered Dissolved Oxygen Transmitter Contents Contents...2 Introduction...3 Range and Display Settings...4 Installation...5 Electrical Installation...6 Calibration...7 EasyCal...8

More information

ph measuring system for hygienic process applications

ph measuring system for hygienic process applications ph measuring system for hygienic process applications Sterile design, CIP-compatible, in-line sterilizable Extremely robust and unbreakable construction Extremely long service life Long calibration intervals

More information

Dissolved Oxygen Guide

Dissolved Oxygen Guide Educat i onser i es Di ssol vedoxygengui de Dissolved Oxygen Guide Introduction Dissolved oxygen probes provide a convenient approach to essentially direct measurement of molecular oxygen. The membrane

More information

Electrochemical Sensor

Electrochemical Sensor ME3-O3 Electrochemical Sensor Manual (Model:ME3-O3) Version V1.2 Valid from May 1 st,2014 Zhengzhou Winsen Electronics Technology Co., Ltd ME3-O3 gas sensor ME3-O3 electrochemical sensor detect gas concentration

More information

e2c 20 - easy to connect

e2c 20 - easy to connect closer contacts Fieldbus Communications e2c 20 - easy to connect e2c 20 / IP 20 Distributed I/O System for Switch Cabinets Switch cabinets and distribution boxes continue to rely on wiring systems that

More information

Treatment Tables Unless otherwise noted, the tables below are reproduced from those in the Taylor DPD 2000 test kit.

Treatment Tables Unless otherwise noted, the tables below are reproduced from those in the Taylor DPD 2000 test kit. Adjustment compounds It is important to know not only what compounds to use in adjusting pool water balance, but also to know what order to add them in. For instance, adding acid to a pool that is not

More information

OWNER S MANUAL NMB SERIES

OWNER S MANUAL NMB SERIES OWNER S MANUAL NMB SERIES NMB Manual V2.0.doc 1. PARTS IDENTIFICATION LIST 1. 5. 2. 4. 3. 6(a). 6(b). Figure 1.1 1. Powerpack with timer option (x1) 2. Cell (x1) 3. Cell Housing (x1) 4. O-ring (x1) 5.

More information

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range: The ECO-Sure (2e) is a high quality, cost effective 2-electrode electromechanical cell designed for the detection of Carbon Monoxide CO in a range of applications but particularly for domestic/residential

More information

Fundamental Pool Water Chemistry Chapter 5 8 6/27/2011 Disinfection: (book definition on page 49)

Fundamental Pool Water Chemistry Chapter 5 8 6/27/2011 Disinfection: (book definition on page 49) CHAPTER 5: THE CHEMISTRY OF CHLORINATION WATER CHEMISTRY: DISINFECTION CHAPTER 6: TYPE OF CHLORINE CHAPTER 7: PROTECTING CHLORINE FROM SUNLIGHT CHAPTER 8: CHLORINE GENERATORS, BROMINE, AND OZONE 2011 1

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

Climatic Independent Level Sensor LAR

Climatic Independent Level Sensor LAR 1 Product Information LAR-361 LAR-761 Climatic Independent Level Sensor LAR Application / Specified usage Authorizations Hydrostatic level measurement in humid ambiance Special applicable for exterior

More information

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

Datasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code

Datasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code Datasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code ENGLISH These quick connect versions allow rapid termination Miniature connector

More information

User Manual. µ-gard MD Electrochemical Carbon Monoxide Transmitter Serial No. MD April, 2011

User Manual. µ-gard MD Electrochemical Carbon Monoxide Transmitter Serial No. MD April, 2011 µ-gard Electrochemical Carbon Monoxide Transmitter Serial No. MD01-002 User Manual April, 2011 Page 2 1 Intended Use... 3 2 Functional Description... 3 2.1 Transmitter... 3 2.2 Sensor... 3 3 Installation...

More information

User Manual. PolyGard DT V4. Electrochemical Carbon Monoxide Transmitter Serial No. DT December, 2008

User Manual. PolyGard DT V4. Electrochemical Carbon Monoxide Transmitter Serial No. DT December, 2008 PolyGard DT5-1112 V4 Electrochemical Carbon Monoxide Transmitter Serial No. DT5-1112 User Manual December, 2008 August 29, 2017 Revision Specifications subject to change without notice. USA 170829 Page

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual

Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual Topline Electronics Limited 2105 This publication may not be copied, in full or in part, without prior written consent

More information

12mm Dissolved Oxygen Sensor Care and Use Instructions

12mm Dissolved Oxygen Sensor Care and Use Instructions 12mm Dissolved Oxygen Sensor Care and Use Instructions How Dissolved Oxygen Sensors Work Your Dissolved Oxygen (DO) Probe is a galvanic electrochemistry device; i.e. it does not require power from your

More information

Dissolved Oxygen/Temp Waterproof Tester

Dissolved Oxygen/Temp Waterproof Tester User's Guide AM-DO-01 Battery Compartment Cap Main Display Dissolved Oxygen/Temp Waterproof Tester Lanyard Connection old/max/min Button Function Mode Button Power / Calibration Button Probe Coller Probe

More information

TH-1800-T TRX-700-CNG Converter

TH-1800-T TRX-700-CNG Converter TH-1800-T TRX-700-CNG Converter low detector The CNG fuel gas flowmeter is so accurate as to meet a demand of measuring the CNG directly by making the most use of our well-established mini-thermal flowmeter

More information

OXY 3690 MP. Measuring transducer for air oxygen

OXY 3690 MP. Measuring transducer for air oxygen T02.0.4X.6C-11 Measuring transducer for air oxygen OXY 3690 MP as of version V1.3 operating manual OXY 3690 MP - LO WEEE-Reg.-Nr. DE 93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26

More information

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION SCENTROID is the global leader in sensory technology providing intelligent environmental solutions across a wide range of industries

More information

EC214 EC215 - EC215R Bench Conductivity Meters

EC214 EC215 - EC215R Bench Conductivity Meters Instruction Manual EC214 EC215 - EC215R Bench Conductivity Meters http://www.hannainst.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments

More information

LDO II AQ 2/2014, Edition 1.5

LDO II AQ 2/2014, Edition 1.5 9623800 LDO II AQ 2/2014, Edition 1.5 USER MANUAL Table of Contents Specifications on page 2 General information on page 3 Product overview on page 4 Installation on page 5 Operation on page 7 Maintenance

More information

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968. TPS Australia - Quality hand-made instruments since 1968. Waterproof Dissolved Oxygen - ph -mv Temperature Meter Dual readout of Dissolved Oxygen and ph/mv Waterproof to IP65 Easy to use One-touch calibration

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

AMS 6916 Board mount pressure sensor with ratiometric analog output

AMS 6916 Board mount pressure sensor with ratiometric analog output FEATURES Piezoresistive pressure sensor with amplified analog output Calibrated and temperature compensated Ratiometric voltage output, 0.5 4.5 V Digital signal conditioning, 12 bit output resolution Differential,

More information

BI-680 Online Dissolved Oxygen Controller Instruction Manual

BI-680 Online Dissolved Oxygen Controller Instruction Manual BI-680 Online Dissolved Oxygen Controller Instruction Manual BANTE INSTRUMENTS CO., LTD BI-680 Online Dissolved Oxygen Controller 1 Introduction Thank you for selecting the BI-680 online dissolved oxygen

More information

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements

More information

MODEL GT820 OXYGEN SENSOR

MODEL GT820 OXYGEN SENSOR INSTRUCTION MANUAL MODEL GT820 OXYGEN SENSOR 70046 The information and technical data disclosed by this document may be used and disseminated only for the purposes and to the extent specifically authorized

More information

AMS 2710 PCB pressure sensor module with V output

AMS 2710 PCB pressure sensor module with V output FEATURES Universal pressure sensor module with 0.. 10 V voltage output Fully calibrated and temperature compensated sensor module Variants for (bidirectional) differential, gage, absolute and barometric

More information

Electrochemical Sensor

Electrochemical Sensor ME3-H2 Electrochemical Sensor Manual (Model:ME3-H2) Zhengzhou Winsen Electronics Technology Co., Ltd ME3-H2 gas sensor ME3-H2 electrochemical sensor detect gas concentration by measuring current based

More information

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal LK-SX CO 2 +VOC Sensor for detection of carbon dioxide (CO 2) and mixed gas content in air ducts Data sheet Subject to technical alteration Issue date: 24.08.2015 Application For detection of CO2 and VOC.

More information

Optical Dissolved Oxygen Meter

Optical Dissolved Oxygen Meter Optical Dissolved Oxygen Meter HI764113 Rugged Optical Dissolved Oxygen Probe for Fresh and Saltwater Applications Digital probe Fast and stable readings No membranes Not affected by sunlight No electrolytes

More information

These variables can be accessed by holding the UP button for 5 seconds.

These variables can be accessed by holding the UP button for 5 seconds. PureSilk Chromatalyzer QUICK SETUP GUIDE Read Owners Manual before operating this unit Only electrically qualified and authorized persons are permitted to service this unit Warranty is void if non-genuine

More information

T02.0.3X.6C-06 Page 1 of 6. Operating Manual for Dissolved Oxygen-Measuring transducer OXY 3610 MP

T02.0.3X.6C-06 Page 1 of 6. Operating Manual for Dissolved Oxygen-Measuring transducer OXY 3610 MP T02.0.3X.6C-06 Page 1 of 6 Specification: Measuring range: Operating Manual for Dissolved Oxygen-Measuring transducer OXY 3610 MP 0.00.. 25.00 mg/l dissolved oxygen Output signal: refer to type plate Accuracy:

More information

RAMZONICS. Saltwater Chlorinator

RAMZONICS. Saltwater Chlorinator RAMZONICS Manufactured Chlorinator Owner s Manual Model 1400 20A Reversing Self-Clean Model 1401 30A Reversing Self-Clean Picture shows Model 1400, 20A. 1401, 30A is specified in the rating under the brand

More information

Electro-Pneumatic Converter YT-940 SERIES

Electro-Pneumatic Converter YT-940 SERIES Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product

More information

Operating instructions TARAtec sensors CD7, PES7, OZ7, WP7

Operating instructions TARAtec sensors CD7, PES7, OZ7, WP7 Operating instructions TARAtec sensors CD7, PES7, OZ7, WP7 April 2017 (EN) V10 Table of contents Table of contents 1 Information about these operating instructions... 4 1.1 Symbols and displays... 4 1.2

More information

MARTINI. instruments. THANK YOU FOR CHOOSING. Sales and Technical Service Contacts:

MARTINI. instruments.   THANK YOU FOR CHOOSING. Sales and Technical Service Contacts: THANK YOU FOR CHOOSING MARTINI instruments Sales and Technical Service Contacts: Milwaukee Electronics Kft. Alsókikötő sor 11. 6726, Szeged, Hungary Tel: +36-62-428-050 Fax: +36-62-428-051 e-mail: sales@milwaukeeinst.com

More information

BS12 Piezoresistive OEM Pressure Sensor

BS12 Piezoresistive OEM Pressure Sensor BS12 Piezoresistive OEM Pressure Sensor Feature Pressure range (-0.1~60)Mpa; Pressure reference: Gauge, absolute and sealed gauge; Constant current power supply; Isolated construction to measure various

More information

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER Features ±0.01% FS Measurement & Control Accuracy ±0.001% /ºC Thermal Stability Pressure Ranges from ±1 psid to 1200 psia Applications Barometric Measurement

More information

User Manual. MagnaMaster and ChloroMaster Electrolytic Chlorinator.

User Manual. MagnaMaster and ChloroMaster Electrolytic Chlorinator. User Manual MagnaMaster and ChloroMaster Electrolytic Chlorinator www.directpoolsupplies.com.au Contents Introducing the MagnaMaster and ChloroMaster 1 How it Works 1 Installation Guide 1 Initial Pool

More information

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS V10K SYSTEM: PROVEN TECHNOLOGY WORLDWIDE IN USE Since Charles F. Wallace and Martin F. Tiernan discovered the first chlorine gas feed system in 1913 the

More information

Oxymax W COS51D. Technical Information. Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor

Oxymax W COS51D. Technical Information. Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor Technical Information Oxymax W COS51D Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor Application The continuous measurement of the concentration of dissolved oxygen

More information

ME3-HCL Electrochemical sensor

ME3-HCL Electrochemical sensor ME3-HCL Electrochemical sensor Manual (Model:ME3-HCL) Zhengzhou Winsen Electronics Technology Co., Ltd ME3-HCL gas sensor ME3-HCL electrochemical sensor detect gas concentration by measuring current based

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information