IMPORTANT: All features subject to change without notice.
|
|
- Alexis Daniels
- 5 years ago
- Views:
Transcription
1 4.0.1
2
3 Table of Contents 1. Contents 4 2. Quick Start 4 3. Icon Key 5 4. Changing GaitSens View / Exiting GaitSens 5 5. Select User 6 6. Validate Setup 7 7. Therapist View 8 8. My Goals 9 9. Replay Session Analysis Export Report User View Balance Select Units Importing Archived Users Updating GaitSens Using Google Play: Calibration Reference - Gait Parameters Reference - Normal Values Warranty 29 IMPORTANT: All features subject to change without notice. 3
4 1. Contents a. Instrumented GaitKeeper Treadmill / Walking Surface. b. GaitSens 2.0 Software installed on Android tablet. c. Charger cord for tablet for Android tablet. IMPORTANT: GaitSens 2.0 is intended for light commercial, rehabilitation, and home use. 2. Quick Start Congratulations on the purchase of the GaitSens 2.0 gait analysis software designed specifically for the busy rehabilitation clinic. This quick reference guide will help you get your GaitSens running quickly. a. Plug the GaitSens enabled treadmill into an appropriate electrical outlet per the specifications of the treadmill. GaitSens is powered from the treadmill so does not require any additional outlet plug. b. Wait at least 15 seconds after the treadmill has been plugged in before opening the GaitSens application in the tablet for Android. c. Click on the GaitSens icon in the provided tablet. Within Bluetooth Range (Less than 30 feet away from treadmill) Outside Bluetooth Range (Greater than 30 feet away from treadmill) Initialize Treadmill i. Ensure treadmill is level with all four adjustable feet touching ground. ii. Remove all weight from the treadmill and ensure the treadmill is not touched during initialization iii. Press Initialize. Error Prompt to: Quit close out the treadmill application Run Disconnected Run the application without connection to review previously recorded sessions. Connect Attempt to reconnect. IMPORTANT: If the treadmill has been moved since the last use of GaitSens, for best results validate that the zero values are accurate. Complete Validation Instructions found on page 7. 4
5 3. Icon Key Therapist View Select User Add User Start Session View Report Scale Selected - Enable Video Video Selected - Enable Scale Open Session Therapist View Session/Replay Event Marker Start Duration Marker Stop Duration Marker Enable Video Cancel Video Record Stop Record Report - Icon Key User View Export Report PDF / Data File Return to Therapist View without Report Print Report Save Report Balance - Test Conditions Both Feet Left Foot Right Foot Both Feet on Foam Left Foot on Foam Right Foot on Foam 4. Changing GaitSens View / Exiting GaitSens Click to select view from drop down list. Select preferred view. GaitSens defaults to Therapist view. Enable Balance Mode. Switch to BiSym App. To exit software select Quit or tablet Back icon. 5
6 5. Select User a. Therapist View - Select User Before Running Session START HERE Select a User Create a new user. NOTE: Select the preferred measurement units by following instructions on page 23.. The Selected User information is displayed here. b. Therapist View - Selecting User Information Select User from List of existing users. GaitSens will contain a Start Up user. Search for User Information using the initials, name or ID. c. Therapist View - Creating New User Each user profile must include the following. User ID Weight User ID must be unique to each user. The following user fields are optional. First Initial Last Initial Clinician 6
7 6. Validate Setup (Required only on first use) i. Select default user on the therapist view screen. ii. After the user has been selected, select start session icon to start session. Confirm that weight is reading properly by standing on each of the four corners of the treadmill walking surface. Review the weight value from the Weight Display in the bottom left window for each corner. Each corner should display the same weight reading within +/- 5 lbs. If one corner displays a weight that varies more than +/- 5 lbs, lower the respective adjustable feet until the reading is within the acceptable +/- 5 lbs range. Start Session iii. Repeat process once more to ensure that weight is within +/- 5lbs on each of the corners of the treadmill walking surface. iv. If it is not possible to reach the acceptable range for each of the four corners of the walking surface, recalibrate the GaitSens following the calibration instructions on page 25. If the treadmill does not calibrate properly, please contact the Mobility Research Service & Parts department at v. Press Stop Session to exit validation and return to the therapist view screen. 7. Therapist View a. Starting Session Start recording a new session for the current user. Load a previously recorded session for the current user. See Section 8.d regarding video capture Load a report if a previously recorded session for the current user. 7
8 7. Therapist View - Continued a. During Session Swing Phase Time: Bars show each step swing phase measurement in seconds. Total Weight Bearing: Table below shows weight. Butterfly shows position of center of mass as the user cycles through the gait phases (see pg. 26). Dashboard displays speed, distance, steps and steps per minute. Step Length: Bars shows each step length. Step Width: Step width shown in green. Note: Missed steps in the capture of the session will show as a gray bar in each of the measurement parameter boxes. b. During Session Elapsed Time Clock: Time since start of session. Duration Markers Start Duration End recording session Left Toe Up Events Right Toe Up Stop Duration Left Heel Strike Right Heel Strike Event Marker Event Marker c. Therapist View Naming and Saving Event Markers at End of Session Durations are indicated by Markers # - # Event Markers are indicated by Enter optional session name for future reference. Enter optional marker names for future reference. Marker # 8
9 d. Enable / Disable Video Capture Mode Scale Readout Selected Video Capture Selected Click to enable video capture option. Click to disable video and return to total weight bearing display. e. During Session - Video Enabled When video is enabled a preview will be shown in the video capture window. Press record icon to capture If video is enabled, the session will display preview until Start Record Video icon is s e l e c t e d. W h e n recording, video display has a red outline. Video will be captured for a maximum of 30 seconds, by default*. 8. My Goals * See Settings screen to remove 30 second limitation. a. Set Goals for gait parameters during a session. Goals will be used as comparison values on reports generated from session results For Definition of report p a r a m e t e r s, s e e Reference section on page 26. 9
10 9. Replay Session a. Replay a Session No Video Start Playback Duration Markers Start Playback Start Duration Pause Playback Stop Duration Event Marker Event Marker b. Replay a Session - Video Playback Enabled Video Markers Video Start Video Stop Event Marker Event Marker 10. Analysis a. Select to analyze between Analyze either the entire duration markers session or the portion selected with Set In and Set Out. Purple bar shows Select to analyze 30 the segment for the seconds analysis. Before Event After Event Indicate the portion of the session to be analyzed and included in the report with Set In and Set Out buttons, while playing back a session. 10
11 b. C l i c k to generate report c. Record optional comments here Zoom in/out with touch screen. For Definition of report p a r a m e t e r s, s e e Reference section on page 26. Press User View to start feedback session - See User View section on page 14. Select Export to generate a PDF file of report data Select Done to return to the Therapist View without saving the report e. Compare results to previous sessions or a set of normal values (see reference section for definition of Normal values). To compare results to previous session, select the name of the session in the drop down in the top right corner. Select comparison data set. Previous Session Name Normal Values Clear comparison values Comparison results will show as a green bar below each report parameter. Current Session Results Comparison Session Results 11
12 11. Export Report a. Export Report Data - Generate a PDF and file of report data GaitSens 2.0 allows you to retrieve reports by ing the report, saving the report and moving it to view on a desktop computer, or printing reports directly from your tablet. After selecting to view a report, select Export. The top line of the popup displayed the defaulted file name User ID-date-time. If desired you can over write this with a different file name. Report Print Report Save Report Enter preferred filed name for report data, or accept default. b. Print Report Data Directly from Tablet Plug the short mini USB cord adaptor into the tablet, unplug the USB from your printer, and plug the Tablet into the printer i. Select Save and Print to File 12
13 ii. Select Nearby USB Select your printer and print. c. Allow Print Share to access USB printer if applicable. d. Transfer to Desktop To transfer the report to a desktop computer, plug the long USB connector from the tablet to the USB port on your desktop. Navigate to the tablet, and locate the GaitSens 2.0 subfolder, and to the subfolder titled with User ID. Below you can see user ID of abcd. Select the PDF or CVS file and move to the desktop. 13
14 12. User View a. User View - Provides your user with real time audible and visual feedback. Select User View to go to the User View screen. Start Session Press Configure To change the displayed parameter on the User view. b. User View Configurations Select the desired Test Parameter to change. For Definition of report p a r a m e t e r s, s e e Reference section on page 26. Select the preferred adjustment of the selected parameter Symmetry Threshold Increase Decrease Enter units - Percent updates. Enter Percent - Units updates. c. User View Feedback - During Session Goal Threshold Visualization of step feed back. Magenta missed goal Selected test goal Step Ratio Successful steps vs. total steps. Step Percentage Percentage of successful steps measured. 14
15 d. User View Feedback - During Session Visualization of step feed back. End Session Green - Successful met goal. Target Goal Threshold SECTION INTENTIONALLY LEFT BLANK 15
16 13. Balance Active User Test Mode Test Duration Selected Test Condition Preview Record / Stop Session Center / Orientation Zoom View Report Balance Test Modes Test Mode Sway Targeting Description Measures the users passive sway distance from a set center point. Measures the users active targeting distance towards changing set points Test Modes Select Balance Mode Click to select test mode. 16
17 Start Balance Preview Preview shows the position of the user s center of mass. Press to start preview mode. Center and Orientation 1. Position the user in the preferred standing position parallel or perpendicular to the sides of the treadmill. 2. Once stationary, press the icon to set the position of the user s center of mass. 3. Next, set the user s orientation by stepping in the region directly in front of the user. Step in front of user. Click to set center reference point 17
18 Test Conditions Use the balance mode conditions to record the user s physical stance configuration. Below is list of the standard feet positions commonly tested in the balance mode. For the Sway test, each condition can be set for recording with the user s eyes open or eyes closed. Both Feet Both Feet on Foam Left Foot Left Foot on Foam Right Foot Right Foot on Foam There are an additional 3 optional fields for user defined custom conditions. Select test condition Click to select test condition. Sway Mode - Measures the user s sway distance from a set center point. User s Center of Mass Center of Mass Reference Sway measure distance from the user set center reference point. 18
19 The sway mode duration can be adjusted to sessions of 30 seconds, 1 minute and 3 minutes. Select Duration Time Session Report - Upon ending the session a session report will be generated summarizing the session. The session report can be saved as a PDF file and view through the PDF viewer on the tablet. Left Anterior Right Anterior Percentage of time spent in quadrant region. Percentage of time spent in semicircle region. Average Distance into the quadrant region. Average Distance into semicircle region. Left Posterior Right Posterior 19
20 Summary Report - To compare multiple sessions, click the Button on the Balance mode screen. Select up to 5 sessions to view on a single chart. Select Sway Target Mode - Measures the user s active targeting distance towards changing set points Target Region User s Center of Mass 5 seconds before changing position, the target changes color from blue to red. Target measures distance from the user s center mass to a changing target region. 20
21 The target distance can be set to distances of 1, 2, and 3 inches away from the user s center of mass. Select Target Distance Session Report - Upon ending the session a session report will be generated summarizing the session. The session report can be saved as a PDF file and view through the PDF viewer on the tablet. Average distance in quadrant region. Target Points 21
22 Summary Report - To compare multiple sessions, click the Button on the Balance mode screen. Select up to 5 sessions to view on a single chart. Select Targeting SECTION INTENTIONALLY LEFT BLANK 22
23 14. Select Units a. Units can be changed by pressing the icon in the top right hand corner and selecting the DISPLAY UNITS option. Select DISPLAY UNITS S e l e c t t h e dimension to toggle the units for. Select the preferred units. 23
24 15. Importing Archived Users a. Therapist View - Import Archived Users On Main Therapist View Press and select Import Users. If Desired, i m p o r t p r e v i o u s l y archived users (optional). Identify Archived User by User ID. Each imported user requires completion of the user Weight. The First Initial and Last Initial fields are optional. b. Therapist View - Import Archived Users Return to Therapist View Delete User Import User 16. Updating GaitSens Using Google Play: The update through Google Play requires a Wi-Fi connection to the tablet and a Gmail account. After the tablet is connected to your Wi-Fi, open the Google Play app on the GaitSens tablet. In Google Play you then search GaitSens and download the software. You also can forward this to the Google account and open the on the tablet. Once located in Google Play, this should give you the option to install the update. Follow the instructions regarding the installation and open the GaitSens application. If you are unable to install the software, please feel free to contact us at for alternative update options. 24
25 17. Calibration NOTE: Calibration should only be performed if values are skewed. Errors in calibration procedure will effect captured data. For assistance during calibration process, please contact the Service & Parts department at EXT Click to calibrate GaitSens. 2. Enter your weight. 3. The calibration will first ask for you to stand off of the treadmill. Additional weight to the treadmill will skew the calibration of the instrumentation. 4. Follow the calibration steps as shown below. 5. The final step asks for you to stand off of the treadmill. Additional weight to the treadmill will skew the calibration of the instrumentation. 6. Press Finish to complete calibration. NOTE: Upon completion of calibration a dialogue box will display the Total Calibration correction coefficient. This value is for Mobility Research Use only. If the calibration fails or if you are experiencing issues with the calibration process, please contact the Service & Parts department at EXT
26 18. Reference Gait Parameters Gait Parameter Definition How GaitSens Calculates Ave Speed Treadmill belt speed Measures actual speed directly from the treadmill Ave Cadence Steps per minute Divides the total number of steps left and right, by the total time. Stride Time Left / Right Stride Length Left / Right Time between heel strike of selected side to next heel strike of same side (Seconds) Distance between center of mass (COM) at heel strike of selected side to next heel strike of same side, (in or cm) Subtracts timestamp of previous step from timestamp of current step of same foot Subtracts location of previous heel strike from location of current heel strike of same foot relative to the moving frame of the walking belt Step Time Left / Right Time between heel strike of opposite side to heel strike of selected side (Seconds) Subtracts timestamp of previous heel strike from timestamp of current heel strike of opposite feet Step Length Left / Right Distance between COM at heel strike of opposite side to heel strike of selected side (in or cm) Subtracts location of previous heel strike from location of current heel strike of opposite feet relative to the moving frame of the walking belt Stance Left / Right Swing Left / Right Double Support Left / Right Percent of time between heel strike of selected side to toe off of same side, compared to total time of selected side stride (%) Percent of time between toe off of selected side to heel strike of same side, compared to total time of selected side stride (%) Percent of time between heel strike of selected side to toe off of opposite side, compared to total time of selected side stride (%) Divides time between heel strike and subsequent toe off of same foot by time between consecutive heel strikes of same foot Subtracts STANCE percentage from 100% Divides time between heel strike of one foot and subsequent toe off of opposite foot from time between consecutive heel strikes of same foot Base Width Left / Right Medial lateral distance between COM at toe off of opposite side to heel strike of selected side (in or cm) Subtracts average lateral location of left foot during right swing from average lateral location of right foot during left swing 26
27 Gait Parameter Definition How GaitSens Calculates Avg WB Left / Right Step Length Asymmetry Double Support Asymmetry Average weight supported during each single stance of selected side, averaged with all single stance through the session (lb or kg) Average asymmetry for step lengths of each stride, averaged over all session strides 0= no asymmetry, > 1=no symmetry Average asymmetry of Double Support of each stride, averaged with all session strides 0= no asymmetry, 1= no symmetry Time-average of total measured load during all single-stance phases of gait for one foot Absolute value of difference in step length between left and right foot divided by average step length of both feet abs(rsl-lsl)/(rsl+lsl) RSL = Right Step Length LSL = Left Step Length Absolute value of difference in left and right double support times divided by average of double support times abs(rds-lds)/(rds+lds) RDS = Right Double Support time LDS = Left Double Support time What does the Butterfly mean? Graphical representation of the COM as the user cycles through the gait phases 27
28 19 - Reference - Normal Values Normal Values: Session results were gathered using a set of 30 "typical" adults who walked on a GaitSens enabled treadmill, at 5 different walking speeds (0.5mph, 1 mph,1.5 mph,2.0 mph, 2.5 mph). The software compares your user s data with the mean of the data collected from this normal population, based upon the average speed of the session. Speed (mph) Stride Length (in) Step Length (in) Stance (%) Swing (%) Double Support (%) Stride Time (s) Step Time (s) Step width (in) Cadence (steps/min) SECTION INTENTIONALLY LEFT BLANK 28
29 Limited Warranty Certificate GaitSens Instrumentation is covered under warranty for 1 year against all defects. Tablet issued for use with GaitSens will be compatible with updates to GaitSens software for a limited duration of 2 years after purchase. After 2 years it may be necessary for the customer to replace their tablet to use a GaitSens update. Tablet issued for use with GaitSens is limited to 3rd party tablet manufacturer specified warranty. No additional warranty is provided. Losses due to work stoppage, lost revenues, damages due to neglect or abuse ARE NOT covered by this warranty. Shipping and handling charges ARE NOT covered by this warranty. Tampering or modification on any and all components by unauthorized personnel is discouraged and will void your warranty. THIS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, REMEDIES AND CONDITIONS, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED. MOBILITY RESEARCH SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IF MOBILITY RESEARCH INC. CANNOT LAWFULLY DISCLAIM IMPLIED WARRANTIES UNDER THIS LIMITED WARRANTY, ALL SUCH WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. NO MOBILITY RESEARCH RESELLER, AGENT, OR EMPLOYEE IS AUTHORIZED TO MAKE ANY MODIFICATION, EXTENSION OR ADDITION TO THIS WARRANTY. MOBILITY RESEARCH IS NOT RESPONSIBLE FOR DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION OR UNDER ANY OTHER LEGAL THEORY, INCLUDING BUT NOT LIMITED TO LOST PROFITS, DOWNTIME, GOODWILL, OR DAMAGE TO EQUIPMENT AND PROPERTY. Warranty excludes damage due to normal wear and tear, tampering with any components, from misuse and abuse, caused by cleaning and acts of God. Warranty does not cover losses due to work stoppage, lost revenue(s), and damages due to neglect. Warranty excludes GaitKeeper Treadmills. Shipping and handling charges are not covered by this warranty. *If present. In order for us to provide the very best in customer support, please activate your warranty by providing the following information. This information will allow us to notify you for product updates, recall information, clinical support, technical support, maintenance information and to receive our E-Newsletter. You may visit our website at warranty.html and submit this form or fill in the information below and mail or fax back. (Keep a copy for your records) Products, Education, and Rehabilitation Solutions Mobility Research Inc., P. O. Box 3141, Tempe AZ Phone: / Fax: warranty@litegait.com
Gaiter Stool User Manual
Gaiter Stool User Manual Gaiter Stool Diagram 1. Adjustable Padded Seat 2. Height Adjustment Lever 3. Adjustable Mounting Arm 4. Stool Base w/casters 5. Pin Inserts for LiteGait Base 1 2 3 5 4 NOTE: Your
More informationWARRANTY, QUICK START GUIDE
WARRANTY, QUICK START GUIDE ONE-YEAR LIMITED PRODUCT WARRANTY BABOLAT warrants to the original purchaser that the BABOLAT PLAY PURE DRIVE (the Product ) is free from defects in material or workmanship,
More informationv2.3 USER MANUAL
v2.3 USER MANUAL www.foresightsports.com Table of Contents 03 04 05 09 12 17 20 21 Activation Getting Started Play Compete Improve Settings Update Manager Glossary 04 11 05 12 03 Activation FSX Activation
More informationRAM 4021 Operation Manual
RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For your safety...3 Description...3 Set-up mode...4 Annunciator lights/alarms...4 Operation...5 Calibration...6
More informationFireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS
FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS WARNING THE WARRANTIES MADE BY MSA WITH RESPECT TO THE PRODUCT ARE VOIDED IF THE PRODUCT IS NOT USED AND MAINTAINED IN ACCORDANCE
More informationPegas 4000 MF Gas Mixer InstructionManual Columbus Instruments
Pegas 4000 MF Gas Mixer InstructionManual Contents I Table of Contents Foreword Part I Introduction 1 2 1 System overview... 2 2 Specifications... 3 Part II Installation 4 1 Rear panel connections...
More informationRAM 4021-DPX Operation Manual
RAM 4021-DPX Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS ABL 4021-DPX / RAM 4021-DPX For Your Safety... 3 Description... 3 Setup Mode... 4 Lights/Alarms... 4 Operation...
More informationSwimNumber App. Build Custom Smart Workouts Control the Wave Propulsion TM System Achieve Health and Fitness Goals INSTRUCTION MANUAL
SwimNumber App Build Custom Smart Workouts Control the Wave Propulsion TM System Achieve Health and Fitness Goals INSTRUCTION MANUAL Table of Contents Warning...2 Connecting to Swim Spa...3-7 Swim Spa
More informationSENSUS PRO MANAGER (for SENSUS or SENSUS PRO devices) User s Guide -- Windows. Version 2.0 Published October 17, ReefNet Inc.
SENSUS PRO MANAGER (for SENSUS or SENSUS PRO devices) User s Guide -- Windows Version 2.0 Published October 17, 2002 2002 ReefNet Inc. 1.0 Introduction The SENSUS PRO data recorder captures the time, depth,
More informationMicrosoft Windows Software Manual for FITstep Stream Version 4
Thank you for purchasing this product from Gopher. If you are not satisfied with any Gopher purchase for any reason at any time, contact us and we will replace the product, credit your account, or refund
More informationRace Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock
Eliminator Competition Stand Alone Mode - Instruction Manual Main Menu: After startup, the Eliminator Competition will enter the Main Menu. Press the right/left arrow buttons to move through the menu.
More informationPitchTracker User Guide. Model: DKPT01 User Guide
PitchTracker User Guide Model: DKPT01 User Guide PACKAGE CONTENTS What Comes in the Box USING YOUR SMART BALL Turn On Your Smart Ball Pair your Smart Ball Turn Off Your Smart Ball Charge your Smart Ball
More informationRAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions
RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....
More informationRAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions
RAM 4021-PR Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-PR For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4
More informationUNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008
UNITY 2 TM Air Server Series 2 Operators Manual Version 1.0 February 2008 1. Introduction to the Air Server Accessory for UNITY 2...2 1.1. Summary of Operation...2 2. Developing a UNITY 2-Air Server method
More informationNEULOG OXYGEN LOGGER SENSOR GUIDE
NeuLog oxygen logger sensor NUL-205 The oxygen sensor can be used for any science experiment or activity where oxygen levels, dissolved or gaseous, are required. Some fields of study include Chemistry,
More informationADVANCED PORTABLE LAUNCH MONITOR. ES14 User Manual
ADVANCED PORTABLE LAUNCH MONITOR ES14 User Manual Table of Contents BASICS OF THE ES14....4-6 POSITIONING THE ES14..... 7-9 KICK STAND RULER SELECTING A CLUB...........10 PROGRAMMING......... 11-24 ALTITUDE
More informationFor Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch)
HAI UPB High Power Wall Switch Dimmer and HAI Auxiliary Switch Installation and Operating Instructions For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer)
More informationClubHub. User s Guide
ClubHub User s Guide Table of Contents Setup... Initial Club Setup...7 Changing Clubs...5 Settings...8 My Clubs... Turn On/Off Sounds...9 Play Round Mode...0 List View...8 Social Sharing...0 Viewing D
More informationRAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions
RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....
More informationGait Analysis System. User Manual and Outcome parameters Patent WO2012/ A1
Gait Analysis System User Manual and Outcome parameters Patent WO212/7855 A1 Thank you for purchasing our Gait Analysis Package. Gait Up s goal is to provide you with a user-friendly setup to measure accurately
More informationRobic M-477 Instructions and Operating Guide
Robic M-477 Instructions and Operating Guide Thank you for buying the Robic M-477 pedometer. Please read these instructions carefully before using it to ensure safe and correct use. Do not expose your
More informationUNIVERSAL MASK TEST SYSTEM
f UNIVERSAL MASK TEST SYSTEM Quotation #110811 Automated Motion Inc. 225 NW Victoria Drive Lee s Summit, Missouri 64086-4709 www.automatedmotion.com SYSTEM OVERVIEW AMI s Universal Mask Test System is
More informationTR Electronic Pressure Regulator. User s Manual
TR Electronic Pressure Regulator Page 2 of 13 Table of Contents Warnings, Cautions & Notices... 3 Factory Default Setting... 4 Quick Start Procedure... 5 Configuration Tab... 8 Setup Tab... 9 Internal
More informationUser's Manual. Heavy Duty Dissolved Oxygen Meter. Model
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
More informationRAM Operation Manual
RAM 4021-1 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-1 For Your Safety... 2 Description... 2 Setup Mode... 3 Lights/Alarms... 3 Operation... 4 Calibration...
More informationKEM Scientific, Inc. Instruments for Science from Scientists
KEM Scientific, Inc. Instruments for Science from Scientists J-KEM Scientific, Inc. 6970 Olive Blvd. St. Louis, MO 63130 (314) 863-5536 Fax (314) 863-6070 E-Mail: jkem911@jkem.com Precision Vacuum Controller,
More informationOperating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com
Operating Manual Software for Fire and Gas Warning Units Order No.: 10154656/01 MSAsafety.com MSA Europe GmbH Schlüsselstrasse 12 8645 Rapperswil-Jona Switzerland info.ch@msasafety.com www.msasafety.com
More informationWalk-O-Meter User Manual
Walk-O-Meter User Manual For BlackBerry Z10 and Q10 Version 2 Date 2013-09-26 1 Thank you for purchasing the Walk-O-Meter App from Cellimagine LLC. Walk-O-Meter pedometer app for your Z10 is the ultimate
More informationQuintic Automatic Putting Report
Quintic Automatic Putting Report Tutorial www.quintic.com Introduction The Quintic Automatic Putting Report is designed to work as an add on to our premier Quintic Biomechanics analysis software. Auto
More informationPutt Metrix for Android User Guide
Putt Metrix for Android User Guide A Step-by-Step guide for getting the most out of your Putt Metrix device. This guide focuses on using Putt Metrix with Android mobile devices such as your smartphone,
More informationGolfNow Central. Rates & Inventory User Guide. February 2018
Rates & Inventory User Guide 2018 1 Table of Contents Rates & Inventory Update Tee Times Load Tee Times Dashboards Autoloads Auto Adjust Rate Fence 3 3 5 7 9 12 13 2 Rates & Inventory To access GolfNow
More informationPRODUCT MANUAL. Diver-Mobile for Android
PRODUCT MANUAL Diver-Mobile for Android Contact details: Van Essen Instruments B.V. Van Essen Instruments - Canada Delftechpark 20 630 Riverbend Drive, Suite 100 2628 XH Delft Kitchener, ON, The Netherlands
More informationPitchTracker Softball User Guide
PitchTracker Softball User Guide Model: DKPTS01 User Guide PACKAGE CONTENTS What Comes in the Box USING YOUR SMART SOFTBALL Turn On Your Smart Softball Pair your Smart Softball Turn Off Your Smart Softball
More informationMac Software Manual for FITstep Pro Version 2
Thank you for purchasing this product from Gopher. If you are not satisfied with any Gopher purchase for any reason at any time, contact us and we will replace the product, credit your account, or refund
More informationIron Filter Installation / Operation Manual
Iron Filter Installation / Operation Manual BrassMaster and BrassMaster Plus Technical Video Library: http://watercontrolinc.com/residential-technical-support/residential-technical-videos BrassMaster technical
More informationMODEL 100 NITROGEN INFLATION CART
MODEL 100 NITROGEN INFLATION CART Installation & Operation Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV120106 P/N: 81-0113 TABLE OF CONTENTS SAFETY
More informationTOMI PRO MODEL PERSONAL MODEL
TOMI PRO MODEL PERSONAL MODEL System requirements Windows System Requirements To use your TOMI and its software, your system should have: A Microsoft Windows compatible PC with a Pentium IV processor (1.5
More informationOwner s Manual Humiport 10/20
4201 Lien Rd Madison, WI 53704 Owner s Manual Humiport 10/20 Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix Humiport line of ThermoHygrometers offers the restoration
More informationBiiSafe Buddy User Guide
1 BiiSafe Buddy User Guide Guide 2 This guide explains how to set up your BiiSafe Buddy and use all of its features. You will need: 1. Your BiiSafe Buddy 2. Your Mobile device (Apple or Android) 3. Data
More informationREMOTE CLIENT MANAGER HELP VERSION 1.0.2
VERSION 1.0.2 MERCHANT SALES: 800-637-8268 New Merchant Accounts PARTNER PROGRAMS: 800-637-8268 New and existing partnerships CUSTOMER CARE: 800-338-6614 Existing merchant account support Statements and
More informationUser Manual. 3BaysGSA PRO - Golf Swing Analyzer 10,000 DATA POINTS CAPTURED PER SWING. [For Android User]
User Manual 3BaysGSA PRO - Golf Swing Analyzer 10,000 DATA POINTS CAPTURED PER SWING [For Android User] PREFACE Congratulations on purchasing the 3BaysGSA PRO( MX-G102a ). The unique combination of features
More informationInventory User Guide
Inventory User Guide User Guide ~ Table of Contents ~ Sign On/Select Facility Rates & Inventory Update Tee Times Load Tee Times AutoLoad Schedule Rate Fences Dashboards Revenue At Risk, Rounds & Revenue,
More informationOxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems
Oxygen Concentrator Installation and Operation Manual ClearWater Tech, LLC. Integrated Ozone Systems 850-E Capitolio Way, San Luis Obispo, Ca 93401 805-549-9724 Fax: 805-549-0306 E-mail: service@cwtozone.com
More informationT i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)
RACEAMERICA T i m i n g S y s t e m s Demo Tree Controller Owner s Manual Models 3204D, 3204DW & 3204DX Rev D RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA 95055-3469 (408) 988-6188 http://www.raceamerica.com
More informationBante821 Portable Dissolved Oxygen Meter Instruction Manual
Bante821 Portable Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante821 Portable Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante821 portable dissolved oxygen
More informationQuick Guide. SGX-CA500 Cycle Computer SGY-PM Series Power Meters
Quick Guide SGX-CA500 Cycle Computer SGY-PM Series Power Meters Easy Installation and Advanced Functionality Fast Facts: Pioneer Power Meter Cranksets and arms ship pre-set in the ANT+ Format Simply install
More informationAFG FITNESS APP OWNER S MANUAL AFG MANUEL DU PROPRIÉTAIRE DU TAPIS ROULANT AFG MANUAL DEL PROPIETARIO DE LA CAMINADORA
AFG FITNESS APP OWNER S MANUAL AFG MANUEL DU PROPRIÉTAIRE DU TAPIS ROULANT AFG MANUAL DEL PROPIETARIO DE LA CAMINADORA Read the GUIDE and OWNER S MANUAL before using this CONNECTED FITNESS MANUAL. Lisez
More informationGait Analyser. Description of Walking Performance
Gait Analyser Description of Walking Performance This brochure will help you to understand clearly the parameters described in the report of the Gait Analyser, provide you with tips to implement the walking
More informationACI_Release_Notes.txt VERSION Fixed Tank info for ELITE in Dive section 2. Fixed USB port initializing for old DC VERSION
VERSION 2.4.0 1. Fixed Tank info for ELITE in Dive section 2. Fixed USB port initializing for old DC VERSION 2.3.9 1. Fixed Dive Computer configuration section error 2. Fixed message for download/upload
More informationPitchTracker User Guide. Model: DKPT01 User Guide
PitchTracker User Guide Model: DKPT01 User Guide PACKAGE CONTENTS What Comes in the Box USING YOUR SMART BALL Turn On Your Smart Ball Pair your Smart Ball Turn Off Your Smart Ball Charge your Smart Ball
More informationUSA Jump Rope Tournament Software User Guide 2014 Edition
USA Jump Rope Tournament Software User Guide www.usajumprope.org Table of Contents Contents System Requirements... 3 System Conventions... 4 Phase 1 Tournament Pre registration Preparation... 5 Name Your
More informationSCALE / SORTER OPERATORS MANUAL (DATED 2004 PRESENT)
SCALE / SORTER OPERATORS MANUAL (DATED 2004 PRESENT) November 2006 MST80205 This page intentionally left blank for notes - 2 - !!!!! CAUTIONS!!!!! NO WELDING NO PLASMA TORCHING MAY RESULT IN ELECTRICAL
More informationASSESMENT Introduction REPORTS Running Reports Walking Reports Written Report
ASSESMENT REPORTS Introduction Left panel Avatar Playback Right Panel Patient Gait Parameters Report Tab Click on parameter to view avatar at that point in time 2 Introduction Software will compare gait
More informationDIVE MEET SCORING INSTRUCTIONS. Day before meet
DIVE MEET SCORING INSTRUCTIONS Day before meet Physical set up Set up registration/scoring table #1 on 1 meter side and scoring table #2 on 3 meter side of diving well, judges chairs, and award stand as
More informationWELCOME TO THE REVOLUTION
USER GUIDE WELCOME TO THE REVOLUTION THANK YOU FOR CHOOSING THE GCQUAD We listened to what you wanted - and created the most accurate, versatile and game-enhancing ball and club analysis solution available
More informationCONSUMER MODEL INSTALLATION GUIDE
CONSUMER MODEL INSTALLATION GUIDE System requirements Windows System Requirements To use your TOMI and its software, your system should have: A Microsoft Windows compatible PC with a Pentium IV processor
More informationGETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP
GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP LIMITED WARRANTY Getz Equipment Innovators warrants its products, and component parts of any product manufactured by
More informationGETTING STARTED. Main MENu SCREEN: When starting E6, the Main Menu screen displays the following buttons:
CONTENTS Getting Started... 2 Play Golf... 5 Players 7 Courses 7 Holes 8 Modes 8 Configuration 10 Start 10 Back 10 Playing A Round 11 E6 Cube Menu for Play Mode 13 Stats & Options Screen 16 Practice...
More informationUser Manual. ENGLISH Pages FRANÇAIS Pages ESPAÑOL Páginas DEUTSCH Seiten 53-69
User Manual ENGLISH Pages 1-18 FRANÇAIS Pages 19-35 ESPAÑOL Páginas 36-52 DEUTSCH Seiten 53-69 LIT# LD2-160212 LD2-Full_Manual Rev18 Thank you for choosing the GolfBuddy LD2. The GolfBuddy LD2 is the first
More informationWickets Administrator
Wickets Administrator Software For Managing Stored Value Wickets 01/08/2008 Product Details And Operating Instructions Overview This page describes each major function of Wickets Administrator in detail.
More informationPedometer with PC download. Model: FB322 OVERVIEW FRONT VIEW INDEX
OVERVIEW FRONT VIEW Pedometer with PC download INDEX Model: FB322 Introduction...1 Overview...1 Front view...1 Back view battery compartment...1 LCD screen...1 Getting started...2 Setting the device...2
More information92831 TEL: (714) FAX:
Document No. 1800-75 Respiration Test Chamber Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA
More informationFireWorks NFIRS BI User Manual
FireWorks NFIRS BI User Manual Last Updated: March 2018 Introduction FireWorks Business Intelligence BI and analytics tool is used to analyze NFIRS (National Fire Incident Reporting System) data in an
More informationTru Flight TRUFLIGHT INSTALLATION GUIDE TRUGOLF.COM
Tru Flight T R A C K I N G S Y S T E M TRUFLIGHT INSTALLATION GUIDE TRUGOLF.COM TruFlight Camera Tracking System Setup & Installation TruFlight : How It Works... 1 TruFlight Components... 1 TruFlight Installation...
More informationCOMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6
COMBAT SWIM BOARD RJE International, Inc. YOUR SOURCE FOR DIVER NAVIGATION AND UNDERWATER RELOCATION EQUIPMENT RJE International Feb 1, 2017 12 TAC-300 Revision 6 RJE International, Inc. 15375 Barranca
More informationHigh Performance Electronic Components 1411 S. Roselle Rd Schaumburg, IL Fax
Air Quality Computer U.S. PATENT #5,509,295 Invented and Manufactured By High Performance Electronic Components 1411 S. Roselle Rd Schaumburg, IL 60193 847-923-0002 Fax 847-923-0004 www.altronicsinc.com
More informationFor The First Time Quad Doppler Radar and Dual Photometric Cameras in One Launch Monitor.» User Manual
For The First Time Quad Doppler Radar and Dual Photometric Cameras in One Launch Monitor» User Manual TABLE OF CONTENTS ES16 TOUR GETTING STARTED Package Contents Installing the Battery Selecting a Club
More informationSENSUS PRO MANAGER (for SENSUS or SENSUS PRO devices) User s Guide Palm OS. Version 2.0 Published October 17, ReefNet Inc.
SENSUS PRO MANAGER (for SENSUS or SENSUS PRO devices) User s Guide Palm OS Version 2.0 Published October 17, 2002 2002 ReefNet Inc. 1.0 Introduction The SENSUS PRO data recorder captures the time, depth,
More informationModel SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA
Calibration Guide Model SM/PL Series Precision Loads Anritsu Company 490 Jarvis Drive Morgan Hill, CA 95037-2809 USA Part Number: 10100-00056 Revision: B Published: January 2010 Copyright 2009-2010 Anritsu
More informationRevision: 23 March 2008 (nk)
CCAP Air Monitoring Protocol #01 Secondhand Smoke Drift Between Apartment Units Version 1.0 California Clean Air Project March 2008 CCAP AIR MONITORING PROTOCOL #01 SECONDHAND SMOKE DRIFT BETWEEN APARTMENTS
More informationUSER GUIDE USER GUIDE
1 TABLE OF CONTENTS GETTING STARTED 2 Included in the box 2 Compatible smartphones 2 Accessories: 2 Download Mobitee and PIQ application 2 GET STARTED WITH MOBITEE AND PIQ 3 Create your Account and Login
More informationGetting to know your Sureshotgps micro V3
Getting to know your Sureshotgps micro V3 Battery State Symbol Satellite Signal Shows distance to front, centre and rear of each green Hole Number Real Time Power on and Enter Key Down (backward) Key 1
More informationPsyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)
GE Sensing Psyclone TM Protimeter Thermo-Hygrometer Operating Manual INS7800, Rev. A (September 2007) Psyclone is a Protimeter product. Protimeter has joined other GE high-technology sensing businesses
More informationThe Complete 100 Day Dash Guide Updated May 7, 2013
The Complete 100 Day Dash Guide Updated May 7, 2013 This guide covers the following topics (click the links to read more): Official Rules Frequently Asked Questions (FAQs) How to Register for the Dash
More informationSoftware Manual for FITstep Pro Version 2
Thank you for purchasing this product from Gopher. If you are not satisfied with any Gopher purchase for any reason at any time, contact us and we will replace the product, credit your account, or refund
More informationAUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP
USER MANUEL AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP TIRE EQUIPMENT MANUFACTURER 1.866.409.RACK WWW.MARTINSINDUSTRIES.COM info@martinsindustries.com PARTS Verify that the following components
More informationTechnology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.
NXT Main Menu My Files Files are automatically placed into the appropriate folders. When you download a program using a Sound file to the NXT, the program will be placed under Software files while the
More informationGolfshot: Golf GPS. ios VERSION 3.0+
Golfshot: Golf GPS ios VERSION 3.0+ CONTENTS Home Screen Rounds Statistics Handicap Index Course Preview GolfNow Tee Times Apple Watch Golfplan Awards Settings Select Facility Round Setup Hole List GPS
More informationHAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions
HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions For the following Models: 40A00-1 HAI 15A Relay Switch (referred to as HAI UPB Wall Switch, in this document), and
More informationMAROC Computing Guide for running an event
MAROC Computing Guide for running an event Document History Date Who Summary 09-Oct-13 Keith Roberts Rewrite for new MAROC laptop and OE2010, based on previous MAROC PC Instructions originally authored
More informationHOW TO RESET CLOCK ON FITBIT DOCUMENT
26 April, 2018 HOW TO RESET CLOCK ON FITBIT DOCUMENT Document Filetype: PDF 229.57 KB 0 HOW TO RESET CLOCK ON FITBIT DOCUMENT So many options to choose from! To set up a FitBit on a computer, install the
More informationINSTALLATION MANUAL Residential and Small Commercial Applications
INSTALLATION MANUAL Residential and Small Commercial Applications WATERTEC S100 INSTALLATION MANUAL Congratulations on selecting the WaterTec S100 kit, the industry s leading soil-moisture sensing unit
More informationAX5000 Operational Manual
MIYACHI AMERICA CORPORATION The World Leader in Hermetic Sealing Systems AX5000 Operational Manual 0 Document #107-00092-001 Dec, 2013 AX5000 Operational Manual Miyachi America Corporation 1820 S. Myrtle
More informationiworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)
Experiment HE-5: Resting Metabolic Rate (RMR) Before Starting 1. Read the procedures for the experiment completely before beginning the experiment. Have a good understanding of how to perform the experiment
More informationTennis...32 Stay above...34 Decimal...36 Bundesliga simulator...38 Shooter management...41 Installation...43 Registration...45 Where do I get the
Content ShotAnalyzer with Scatt and the Häring target system... 3 ShotAnalyzer with Scatt and the Meyton target system... 5 ShotAnalyzer with Scatt and the Disag target system... 7 ShotAnalyzer with Scatt
More informationTechnology. Using Bluetooth
Bluetooth is a communication technology that makes it possible to send and receive data without using wires. Using the Bluetooth features, you can set up a wireless connection between your NXT and other
More informationSontek RiverSurveyor Test Plan Prepared by David S. Mueller, OSW February 20, 2004
Sontek RiverSurveyor Test Plan Prepared by David S. Mueller, OSW February 20, 2004 INTRODUCTION Sontek/YSI has introduced new firmware and software for their RiverSurveyor product line. Firmware changes
More informationBIODEX. SOFTWARE MANUAL User s Guide. ADDENDUM GAIT TRAINER TM 3 AND RTM600 TREADMILL Version
ADDENDUM GAIT TRAINER TM 3 AND RTM600 TREADMILL Version 2.02 SOFTWARE MANUAL User s Guide 950-400 950-402 950-406 950-420 950-422 950-426 BIODEX Biodex Medical Systems, Inc. 20 Ramsey Road, Shirley, New
More informationPGA3510 Portable 3-Gas IR Analyzer. Operations Manual
PGA3510 Portable 3-Gas IR Analyzer Operations Manual Please read, understand, and follow these instructions before operating this equipment. Super Systems, Inc. is not responsible for damages incurred
More informationGE Measurement & Control
GE Measurement & Control Psyclone Protimeter Thermo-Hygrometer Operating Manual INS7800, Rev. C August 2013 Psyclone is a Protimeter product. Protimeter has joined other GE high-technology sensing businesses
More informationUser s Manual. USB Golf Simulator. Contents
USB Golf Simulator User s Manual Contents safety information...1 identifying the components...2 assembly in 3 easy steps...3 plug & play...4 playing tips...5 care...6 troubleshooting...7 notes...8 warranty...9
More informationINSTALLATION MANUAL. Residential and Small Commercial Applications. Sensors just make sense
INSTALLATION MANUAL Residential and Small Commercial Applications Sensors just make sense WATERTEC S100 INSTALLATION MANUAL Congratulations on selecting the WaterTec S100 kit, the industry s leading soil-moisture
More informationARCCOS 360 NEW USER GUIDE
ARCCOS 360 NEW USER GUIDE Table of Contents 1. Getting Started a. Download & Install.2 b. Create Account....3 c. Pair Clubs..4 2. Play a. Starting a Round..5 b. Shot Editing.6 c. Shot List.7 d. Flag &
More informationDigital Vacuum Regulator
Temperature Control for Research and Industry Digital Vacuum Regulator User s Manual Model DVR-280 INDEX SECTION PAGE 1. QUICK OPERATING INSTRUCTIONS............................. 3 KEM-NET DATA LOGGING
More informationPlié 3 Microprocessor Knee
Plié 3 Microprocessor Knee 01 Plié 3 MPK Key Features Plié 3 MPK Key Features Ease of Set Up Using Set Up Wizard in Plie Control Software Advanced & Customisable Stumble Recovery Stumble recovery parameters
More informationHPICAL Operation & Data Logging Procedures. Click spacebar to advance through slides 1
HPICAL-15000 Operation & Data Logging Procedures Click spacebar to advance through slides 1 WARNING Always wear proper safety equipment when using high pressure equipment. Do not exceed 125 psi air pressure.
More informationU S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS
U S E R M A N U A L Model: PM4300 Series (PM4351 Shown) SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090
More informationExperiment HE-9: Resting, Active, and Exercising Metabolic Rates
Experiment HE-9: Resting, Active, and Exercising Metabolic Rates Before Starting 1. Read the procedures for the experiment completely before beginning the experiment. Have a good understanding of how to
More informationModule 3 Developing Timing Plans for Efficient Intersection Operations During Moderate Traffic Volume Conditions
Module 3 Developing Timing Plans for Efficient Intersection Operations During Moderate Traffic Volume Conditions CONTENTS (MODULE 3) Introduction...1 Purpose...1 Goals and Learning Outcomes...1 Organization
More information