Halsey Taylor Owners Manual

Similar documents
Halsey Taylor Owners Manual

Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD

Halsey Taylor Owners Manual

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

Owners Manual. Models 4420BF1U & 4420BF1L Floor Mounted Bi-Level Bottle Filler Tubular Fountain

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual STOP!

Owners Manual Models 4430BF3, 4430BF2 & 4430BF1 Floor Mounted Tri-Level Bottle Filling Tubular Fountain

PAGE (Rev. A - 06/17)

Installation/Care/Use Manual

Installation and Use Manual

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

Installation Instructions

Installation Instructions

LK4420BFFR - FTN, 4420BFFR - FTN. Owners Manual

INSTALLATION INSTRUCTIONS

Pressure Dump Valve Service Kit for Series 2300 Units

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

INSTRUCTION MANUAL. January 23, 2003, Revision 0

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

Operating Instructions Models and Hydrostatic Test Pumps

K Page 1 of 48 Air Intake - Pg. 17

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Floor Drinking Systems

Carter Option X Valve connector assembly. Maintenance manual

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

INSTALLATION INSTRUCTIONS

Medical Gas Control Panel

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

CO2 Tank Conversion Kit P.N , P.N , and P.N

Installation, Operation and Maintenance Manual for Back Pressure Regulator

PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Pressure Dump Valve Service Kit for Series 3000 Units

INSTALLATION AND SERVICE MANUAL FOR LANCER DISPENSING TOWERS

INSTALLATION INSTRUCTIONS

Vibration isolation system 1VIS10W. User manual

STEP 3 GLASS FINISHES. Empire Floral Victorian Deco Tulip Tulip Border Traditional Roman Battuto Confetti Tebori Arabesque Palmier

VOLUMATIC WATER REGULATOR

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

UltRo Dual Flow Reverse Osmosis Water System

BPB26-1 AND SSPB26-1 PATIO BASE INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS SAFETY FIRST!...3 BASIC OPERATION...4 ADJUSTMENTS...5. Cocking Pressure...5. Three-Way Valve Adjustment...6

Multi-Probe Sampling System User Guide & Manual

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

Installation Instructions

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

AIR/OVER HYDRAULIC JACK 20 TON

PVQ 13 A2 R SE 1 S 20 C-11 D

Parts Manual HEAVY DUTY RIGHT HAND ARM

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

Operating Instructions Models and Hydrostatic Test Pumps

Parts Manual STRIKER Striker 2840 Parts List - PN Printed in USA 03/18/08

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

BP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS

CentriFlow Meter Integrated Air Entrainment System

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Speed control assembly model A-1

2.5 & 5.0 GALLON PRESSURE TANKS

APPENDIX A MAIN ASSEMBLIES

Operation Manual Piston Sensed Gas Pressure Regulators

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Installation Troubleshooting Maintenance Instructions Installation / Start-up

Booster Pump PB4-60 Replacement Kits

15000 Series Exhausting Arm - Wall Mount Models: 15076/15106/15146

DelVal Flow Controls Private limited

Continental Industries TRANSITION FITTINGS or FAX Visit

HP-104 & HP-106 Tapping Machine OPERATIONS MANUAL

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

GX200 QX2 ENGINE, JPN, VIN# GCAE Page 1 of 34 AIR CLEANER (DUAL)

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Operating Instructions Models and Hydrostatic Test Pumps

OPERATING AND MAINTENANCE MANUAL

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

TECHNICAL DATA CAUTION

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

3190A NEO-ANGLE DOOR INSTALLATION INSTRUCTIONS. Series MODEL NO

Yoke Block Instruction Manual

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Parts Manual. Versa Hand Arm

Operation Manual Guillotine Cutter RC-5

35 TON HYDRAULIC PUNCH WARNING

Owners Manual Bottle Filler Freeze Resistant Tubular Fountain & Pet Fountain with 98837C Dual Valve Control Assembly

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

830 SureFlo Soap Systems Installation Instructions. Foam Soap Cabinet... Pages 2-9 Liquid Soap Cabinet... Pages 10-19

DESIGN AND PRE - INSTALLATION INFORMATION

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

ASSEMBLY & USE MANUAL

WIDDER TOOLS. HPICAL Calibration Station 1 (203)

3.5 litr es per INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap

Transcription:

Halsey Taylor Owners Manual Non-Refrigerated Fountains OVL-EBP OVL-SBP OVL-SEBP OVL-ESBP Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE ITRUCTIO BEFORE STARTING THE ITALLATION. CHECK YOUR ITALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference. IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON IMPORTANT! ITALLER PLEASE NOTE. THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELEC- TROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE ITALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. 1/4" O.D. TUBE WATER INLET TO COOLER 3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY BUILDING WATER INLET OPERATION OF QUICK CONNECT FITTINGS SIMPLY PUSH IN TUBE TO ATTACH TUBE IS SECURED IN POSITION PUSH IN COLLET TO RELEASE TUBE FIG. 1 NOTE: WATER FLOW DIRECTION SERVICE STOP (NOT FURNISHED) FIG. 2 PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE 23 24 15 FIG. 3 FIG. 4 PAGE 1 14 Regulator Mounting Bracket 97638C (Rev. A - 11/00)

OVL - EBP/SBP/SEBP/ESBP COOLER ITALLATION 1. Wall should already be framed for the fountain using the rough-in dimensions shown in Fig s. 5,6,7, or 8. Shown dimensions pertain to installation location (framing must support up to 150 lbs. weight for single fountain and 300 lbs. for dual fountains). These dimensions are required for compliance with AI Standard A117.0. 2. Attach wall plate assembly to wall as shown in Fig s. 5,6,7, or 8 using 5/16" x 2" long bolts and flat washers (not provided). Tighten securely. (Fastener must match wall type, i.e. lag screws for wood studs, bolts and anchors for masonary construction.) 3. Install back panel. Place the upper edge of the panel above hanger on the wall. Slide the panel down until it engages the hanger. Be sure back panel is firmly engaged before releasing it. 4. Install rough-in plumbing as shown in Fig s. 5,6,7, or 8. Waste line should extend a minimum of 2" (51mm) thru the back panel. Run supply water inlet line thru back panel. Install a service stop (not provided). Turn on supply water and flush thoroughly. 5. Remove bottom access panel from fountain basin and save the screws. Install the fountain to the back panel and wall using (4) 5/16 x 3/4 long bolts and washers (provided) thru holes in back panel. Washer used on bottom two (2) holes only. Tighten securely. 6. Cut waste tube to required length using plumbing hardware and trap (not provided) as a guide. Install hardware and trap. Tighten securely. 7. Make water supply connections from service stop to the fountain strainer. Insert the water inlet line into the inlet side of strainer until it reaches a positive stop - about 3/4" (See Fig. 2). Turn on water supply and check for leaks. Newly installed water supply line should be insulated after leak check is completed. DO NOT SOLDER TUBES IERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT. 8. Check stream height from bubbler. Stream height is factory set at 45-50 PSI. If supply pressure varies greatly from this, adjust the screw on regulator (item 14, on page 1). Clockwise adjustment will raise stream height and counter-clockwise will lower stream height. For best adjustment stream height should be approximately 1-1/2" (38mm) above the bubbler guard. (See Figure 3) 9. Water Valve Mechanism - ADJUSTMENT PROCEDURE: - Turn adjustment screw (Item 26, page 7) counter-clockwise until water flow from bubbler starts - Turn adjustment screw clockwise until water flow stops, then turn an additional 1/2 turn 10. Replace bottom access panel to fountain using the screws provided. Tighten securely. 97638C (Rev. A - 11/00) PAGE 2

LEGEND: A = 1-1/4" O.D. Waste Tube (Trap And Elbow Not Provided) B = 3/8" O.D. Unplated Copper Tube Connect (Water Inlet) C = 1/4" (6mm) DIA. Holes For Mounting Plate To Wall ROUGH-IN FOR OVL-EBP FINISHED FLOOR FIG. 5 PAGE 3 97638C (Rev. A - 11/00)

LEGEND: A = 1-1/4" O.D. Waste Tube (Trap And Elbow Not Provided) B = 3/8" O.D. Unplated Copper Tube Connect (Water Inlet) C = 1/4" (6mm) DIA. Holes For Mounting Plate To Wall ROUGH-IN FOR OVL-SBP FINISHED FLOOR FIG. 6 97638C (Rev. A - 11/00) PAGE 4

LEGEND: A = 1-1/4" O.D. Waste Tube (Trap And Elbow Not Provided) B = 3/8" O.D. Unplated Copper Tube Connect (Water Inlet) C = 1/4" DIA. (6mm) Holes For Mounting Plate To Wall ROUGH-IN FOR OVL-SEBP FIG. 7 FINISHED FLOOR PAGE 5 97638C (Rev. A - 11/00)

LEGEND: A = 1-1/4" O.D. Waste Tube (Trap And Elbow Not Provided) B = 3/8" O.D. Unplated Copper Tube Connect (Water Inlet) C = 1/4" DIA. (6mm) Holes For Mounting Plate To Wall ROUGH-IN FOR OVL-ESBP FIG. 8 FINISHED FLOOR 97638C (Rev. A - 11/00) PAGE 6

16 3, 4 See Fig. 4 21 17 See Fig. 10 18 5 10 6 See Fig. 11 1 8 7 9 8 12 13 11 FIG. 9 PUSH BAR MECHANISM REGULATOR MOUNTING MECHANISM 19 22 31 29 30 2 26 29 26 27 20 Stream Height Adjustment 25 FIG. 10 FIG. 11 PAGE 7 97638C (Rev. A - 11/00)

ITEM NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 PART NO. 26990C 26988C 55836C 55991C 51546C 45396C 100322740560 160270508640 45400C 101570540560 51575C 110346220550 101637451550 161637308640 45398C 45683C 45682C 100023340560 161570808550 61314C 50986C 27006C 27342C 27000C 27344C 70861C 55840C 55839C 27002C 27338C 27004C 27340C 26992C 15005C 40045C 27008C 70856C 70854C 50198C 51468C 22646C 22635C 22797C 27885C 22799C 27887C 26958C 27889C 22795C 27891C 28120C 28121C 28168C 28169C 55996C 15008C 56092C 75541C 111577243890 PARTS LIST OVL-EBP*C, OVL-SBP*C, OVL-SEBP*F, OVL-ESBP*F DESCRIPTION Bottom Cover (OVL-S) Bottom Cover (OVL-E) Push Arm Actuator Push Arm Actuator - AG Bubbler Bubbler - AG Bubbler Gasket Strainer Plate Strainer Plate - AG Drain Gasket Packing Ring Drain Nut Friction Ring Drain Plug Drain Plug - AG Waste Elbow (OVL-E) Waste Elbow (OVL-S) Waste Tube Gasket Slip Nut Regulator Regulator Holder Basin Basin - AG Basin Liner Basin Liner - AG Screw # 10-24 x 2 Top Plate - Actuator Bottom Plate - Actuator Arm w/weldnuts (OVL-E) Carrier Arm - AG (OVL-E) Arm w/weldnuts (OVL-S) Carrier Arm - AG (OVL-S) Regulator Mounting Bracket Nut - Retaining Nut Hex - UNPLTD Reaction Bracket Screw #10-24 x.38 PHMS Rod - Pivot Bushing Snap Bumper - Reg. Valve Assy Reg. Arm Assy Arm - Reg. Adjust Back Panel (OVL-EBP) Back Panel (OVL-EBP) (AG) Back Panel (OVL-SBP) Back Panel (OVL-SBP) (AG) Back Panel (OVL-SEBP) Back Panel (OVL-SEBP) (AG) Back Panel (OVL-ESBP) Back Panel (OVL-ESBP) (AG) Wall Plate Assembly - OVL-SBP Wall Plate Assembly - OVL-SEBP Wall Plate Assembly - OVL-EBP Wall Palte Assembly - OVL-ESBP Strainer Bubbler Nipple Assy Tube - Poly 48.00" Washer-Flat.339/.359ID Steel Screw-Mach. 5/16-18 x 3/4 TROUBLE SHOOTING AND MAINTENANCE Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round file or small diameter wire. CAUTION: DO NOT file or cut orifice material. Stream Regulator: If orifice is clean, regulate flow as in STREAM HEIGHT ADJUSTMENT instructions on pg 2. If replacement is necessary, see parts list for correct regulator part number. Actuation of Quick Connect Water Fittings: Fountain is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing.(see Fig.2) To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4". CAUTION: Cleaning of Aztec Gold Models requires special care. Outer surfaces must be cleaned with a mild detergent or mixture of vinegar and water only, rinsed and wiped dry. Abrasive and acidic cleaners may eventually damage the Aztec Gold finish. SEE DETAIL (ON PAGE 7) SEE PUSH BAR MECHANISM (ON PAGE 7) SEE DETAIL (ON PAGE 7) 32 33 32 SEE PUSH BAR MECHANISM (ON PAGE 7) 33 2222 CAMDEN COURT OAK BROOK, IL 60523 630.574.3500 PRINTED IN U.S.A. FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620 97638C (Rev. A - 11/00) PAGE 8