Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.
|
|
- Rosalind McCarthy
- 6 years ago
- Views:
Transcription
1 Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using electricity. Energy and cost saving will be achieved in total manufacturing lines, since pressure can be increased at the required point in plant. tank and optional pressure gauge directly combined to air are also available. Features Boosting up to double ratio Boosting ratio is adjusted within range of twice primary pressure (.0MPa max.) by pressure adjustment knob, since boosted with compression by piston. Flexible installation This can be installed vertically due to flexible installation attitude. Pipe can be connected from 3 directions. Tool not required pressure adjustment Enabling pressure adjustment by single hand and lock by one push. Futhermore knob can be easily manually adjusted even for high pressure setting. Longitudinal direction shortened compact shape. C O N T E N T S Series variation 8 Product introduction 8 Safety precautions 8 (ABP) 86 tank (AT) 8 : Standard, : Option nic sensor Pressure OUT port position Option Model Model no. JIS symbol Same side of IN port ( ) Bottom tank directly connected Rear side of IN port Pressure gauge Foot bracket Page Blank D L G S B ABP IN OUT 86 EXH 8
2 Double high compressed air is obtained. less air ABP Produce high compressed air (.0MPa max.) up to twice primary pressure (equivalent). (Option) longitudinal direction Pressure adjustment knob Tool not required and a lock by one push Pressure gauge (option) For primary pressure and secondary pressure Primary pressure (supply pressure) nic Boosting to twice pressure sensor Pressure Set screw Flexible installation attitude design and flexible installation Always read precautions on page 8 before starting use. 8
3 Plant wide total cost reduction is achieved. Pressure source Example of increasing thrust of cylinder for welding Pneumatic cylinder Low pressure line air unit Regulator Pneumatic 5 port solenoid valve Regulator Medium pressure line tank AT tank Regulator High pressure line ABP nic sensor Pressure Other applications. Downsized air cylinder. Improving unsatisfied actuator (air cylinder, air motor etc.) output 3. High pressure and quick filling to air tank. Boosting in explosive environment 5. For pressure change (such as pressure decrease of line) of plant line 83
4 ABP Series WARNING Pneumatic components Safety precautions Always read this section before starting use. Refer to Intro 67 for general precautions. Do not use the air for continuous operation such as in a compressor. The air is designed for partial boosting in a factory, etc. Life is shortened if used for high frequency continuous operation, such as in a compressor. (The air 's nominal life is approximately 5 million times when used under normal conditions) Refer to page 87 for the estimate life calculation. Design & Selection CAUTION Do not use this product if vibration exceeds 50 m/s or impact exceeds 300 m/s. Pressure is raised by air pressure, so half of the air is discharged during boosting. If the secondary side flow rate must be, the primary side requires a flow rate of + =. The inside is cylindrical, so noise of 60 to 80 db (primary side 0.9 MPa and secondary side 0.95 MPa for measurement of m) is generated during boosting. * This is noise when a silencer is used. nic sensor Pressure WARNING Do not supply pressure exceeding 0.99 MPa onto the primary side. Check that set pressure does not exceed 0.99 MPa. CAUTION Install a on the primary side to remove rust, foreign matter, and drainage. The air compresses compressed air so drainage is discharged easily from the secondary side. Installation of a is recommended to remove any moisture from piping. Install primary side piping at /B and over to attain sufficient flow. Install a silencer (SLW-5A, SL-5) or exhaust cleaner (FA30-5A) on the exhaust port of the air. When using exhaust cleaner, common porting of the exhaust port is recommended. Use piping with a stop valve to the air tank's drain port. Regularly discharge from the tank. Installation & Adjustment There are no set regulations regarding the air 's installation angle, it should optimally be horizontally installed on a flat surface. Install the air using -M8 depth 0 screw holes on the bottom or -M0 depth 5 screw holes on both sides. Use these screw holes only for installing the air. -M8 depth 0 OUT port position D rear side (air tank fixing side) The bolt used to install the air must not exceed the screw hole depth. Forcibly tightening a long bolt could damage the screw hole and cause air leakage. CKD edge -M0 depth 5 8
5 ABP Series A foot bracket installed on both ends is available as an option. (Model no. ABP--B) Fix the air tank with the - ø3 anchor bolt hole on the bottom. When directly connecting the air to the air tank (AT-), use OUT port position D, and mount the enclosed with the air tank on the air. Then, fix to the top of the air tank with a hexagon head bolt. Hexagon head bolt Hole -ø3 Installation of an air tank and after the air is recommended for attaining stable secondary pressure. WARNING Stop primary pressure and release secondary pressure before maintenance, inspecting, or repairing the air. During Use & Maintenance CAUTION When setting pressure, lift the pressure adjustment knob to release the lock, and then the pressure adjustment knob. Secondary pressure increases when the pressure adjustment knob is turned clockwise. Pressure adjustment knob must be locked after using. If primary pressure exceeds set pressure due to fluctuation in pressure, etc., air is released from the pressure adjustment knob. Set a on the primary side, and adjust the pressure at least 0.MPa lower from the set pressure. nic sensor Pressure The silencer and pressure gauge are consumables and must be regularly replaced. *Refer to the separate Maintenance Manual (ST-30606) for the maintenance procedures. 85
6 nic sensor Pressure Functional explanation Primary pressure flowed from IN passes through check valve on IN side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve, and flows in drive room A. Piston moves to left hand due to pressure of drive room A. in chamber A is compressed, and passes through check valve on OUT side, and goes to OUT side. If piston reaches stroke end, changeover switch is pushed, and compressed air is supplied to pilot room of switching valve, and switching valve is switched. Then the air in drive room A is exhausted, and the air is delivered to drive room B. Therefore, piston moves to right hand and air in chamber B is compressed, and passes through check valve on OUT side, and goes to OUT side. Boosting on OUT side is compressed, if operations above are repeated. Feedback pressure is transmitted to pressure adjustment section due to OUT side pressure passes through shuttle valve, and boosting is continued until pressure adjustment spring and pressure is balanced. ABP Series JIS symbol Specifications Descriptions Working fluid Max. working pressure MPa Min. working pressure MPa Set pressure range MPa Withstanding pressure MPa Flow m 3 /min. (ANR) Boosting ratio Ambient temperature range C Lubrication Port size Weight kg Product sevice life How to order ABP D G Internal air circuit diagram Drive room B Fixed orifice ABP Compressed air From primary pressure+0.mpa to twice primary pressure (0.99MPa max.).5 Refer to the right graph rate flow characteristics Max. double pressure (or equivalent) 0 to 50 (no freezing) Not required (use the turbine oil Class ISO VG3 if lubricated) Rc/.6 5 million (nominal) Switching valve Booster chamber B A OUT port position Blank Same side of IN port D Bottom (air tank directly connected) L Rear side of IN port B Option G Pressure gauge S B Foot bracket IN side check valve Pressure adjustment section Booster chamber A Note) Option G (pressure gauge) is installed onto air at shipment. B (foot bracket) and S (silencer) are attached. IN (primary pressure) Drive room A Select switch Piston OUT side check valve Piston OUT side (secondary pressure) 86
7 ABP Series Specifications Flow characteristics (With air tank AT- installed, double pressure increase) Secondary pressure (MPa) MPa 0.MPa Primary pressure 0.5MPa Pressure characteristics (Setting: Primary pressure 0.69MPa, secondary pressure 0.97MPa, flow rate 0.0m 3 /min.anr) Secondary pressure (MPa) Flow (m 3 /min. (ANR)) Flow rate characteristics show max. flow rate of air. If primary pressure is constant and secondary side flow rate is increased, max. secondary pressure decreases. Note) needs approx. twice secondary side flow rate (max.) for primary side due to structure. Confirm that the instantaneous flow rate is within the curve. Filling characteristics Filling time (second/ ) Boosting ratio (time) Filling characteristics show relations between boosting ratio and filling time, if tank etc. filled with compressed air. To find filling time, when filling tank with air, where secondary side air pressure P0, air pressure in tank before filling P, air pressure after filling P, boosting ratio before filling k and boosting ratio after filling k, therefore k = P and k = P are led. P0 P0 Find k and k at first, then read filling time t and t according to graph where boosting ratio k, k, finally filling time for tank capacity A ( ) is obtained with t = (t-t) A Primary pressure (MPa) Pressure characteristics show variation of set secondary pressure according to primary pressure variation. If primary pressure is decreases, secondary pressure decreases slightly. Pulsation Pulsation width (MPa) Tank capacity ( ) Pulsation shows width of pulsation if air tank is installed onto secondary side of air. Formula of air operational cycle N= Formulation of air service life Since nomin.al service life of operational cycle is 5 million T= Q P ,000,000 N60 AT- N : Operational cycle Q : Required flow (m 3 /min.(anr)) P : Primary pressure (MPa) T : Service life (hour) nic sensor Pressure Each characteristics are just reference, but not assured conditions. 87
8 ABP Series Internal structure E PUSH T E E A-A cross section nic 55 sensor Pressure A 65 CKD A
9 ABP Series Parts list Part list No. Parts name Material Quantity No. Parts name Material Valve stem (A) C type snap ring for hole Body block assembly Spring Spacer ball Packing seal Detection valve body Valve stem (B) Pipe Tie rod Plug with hexagon head hole Plain washer Spring washer Hexagon nut MY packing seal Rod bushing Cylinder tube Piston rod Piston Piston packing seal Head cover Cap Gasket Lip packing seal Piston Cylinder Hexagon socket head cap bolt Cylinder Lip packing seal Piston Spool Stopper Copper alloy Oil impregnated bearing alloy Soft packing seal Spacer Spacer Soft packing seal C type snap ring for hole Spring sheet Spring Valve seat Slip ring Adjusting assembly Guard Mounting nut Adjusting spring Diaphragm assembly Valve seat Bottom spring Stud Knob Valve assembly Regulator assembly Cross-recessed tapping screw Fixed orifice Master valve gasket Hexagon socket head cap bolt Cross headed pan Gasket Valve Plug Spring washer Urethane rubber Urethane rubber PBT resin Copper alloy Copper alloy Copper alloy Discrete consumable parts and options Parts name Model no. Part number Remarks Select switch packing set ABP-K, 3 5, 6,,, 3 Quantity 8 nic sensor Pressure Cylinder section packing seal set ABP-K 8 5, 6,, 3, 7 Switching valve piston assembly Switching valve sealant assembly shuttle valve assembly ABP-K3 ABP-K ABP-K5 3, 3, 37, 38 0,,, 3, 8, 50, 5, 53, 5 Using parts prior to minor changes Diaphragm assembly ABP-K6 60 Pressure adjustment section valve assembly ABP-K7 6, 6, 67, 69 assembly ABP-K8 8, 53, 5 Bracket ABP-B For unit Pressure gauge ABP-GAUGE Pressure gauge pc. SLW-5A pc. 89
10 nic sensor Pressure ABP Series Dimensions ABP- Optional dimensions ABracket (ABP-B) installation 95 -ø Rc/ IN Rc/ IN Rc/8 IN gauge port Rc/ OUT E L PUSH L to IN OUT LO CK H 5 65 IN OUT H 50 E CKD Rc/ OUT APressure gauge (ABP-GAUGE) A (SLW-5A) R/ R/ ø7 ø Rc/ EXH Rc/8 OUT gauge port () (0) (7) 7 5 -M0 depth Rc/ (OUT port position: L) OUT -M8 depth0 60 Rc/ OUT (OUT port position: D) (98) Rc/(OUT port position: L) OUT 80
11 6 Features tank directly connected to air ABP- with compact body. tank (related AT Series JIS symbol Specifications Descriptions AT Working fluid Max. working pressure Hydraulic test pressure MPa MPa Compressed air Ambient temperature range C 0 to 50 (no freezing) Capacity Port size Material Weight m 3 kg 0.0 Rc/ 7.5 Note:, hexagon head bolt and spring washer are attached to install air. How to order AT tank Capacity Dimensions Rc/ A ø36 Part model no. AT-K (, hexagon head bolt, spring washer) ±0.3 30±0.3 Rc/ nic sensor ø ± Pressure 00± -ø Fixing 00± 60±0.3 30±0.3 ø ø A view Rc/
EXH. Specifications. Descriptions. Min. working pressure MPa
Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,
More informationMaximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications
Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range
More informationBooster Regulator/Air Tank
Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed
More informationAir Saving Valve. Pressure Valve Flow Valve
Air Saving Valve Series Series Pressure Valve Flow Valve % reduction in air consumption Cuts air consumption by operating the return stroke at a reduced pressure. valve Pressure Air consumption reduction
More informationVACUUM REGULATORS CONTENTS
CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate
More informationPower Valve: Precision Regulator. High precision, large capacity relief regulator
Power Valve: Precision Regulator Series VEX High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air
More informationSeries VBA1110 to 4200
Booster Regulator Series 0 to 4200 Specifications increase ratio Max. supply pressure Set pressure range Ambient and fluid temperature Lubrication Installation adjustable mechanism 0-02 400-04 Handle operated
More informationSeries variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )
Series variation High damping effect and types of materials Model / appearance Metering valve with silencer Model no. SMW-6 SMW-8 FMS-M SMW- SMW- (R) M M /8 / /8 / / / / 6 8 Effective sectional area (mm
More informationNew Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A
Air Consumption 70% Down New Product Precision Regulator Air Saving Type RPE Series PRECISION REGULATOR RPE SERIES Large Air Saving CC-1072A Air Consumption 70% Down. New Type Eco-friendly Precision Regulator
More informationAir Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv
CAT.ES-173 A Air Saving Valve % reduction in air consumption Cuts air consumption by operating the return stroke at a reduced pressure. valve Pressure Air consumption reduction ratio (%) 3 1.1.1...3 pressure
More informationDirect Operated Precision Regulator Modular Style. Standard Specifications
1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com
More informationAuto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance
More informationHow to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size
Booster Regulator Series VBA How to Order VBA 0 series VBA 0 0 Body size /4 Pressure: MPa Pressure increase ratio 0 Twice Thread type Symbol F Thread type G Port size Symbol Port size 0 /4 Symbol VBA0-0
More informationPilot Check Valve: Metal Body Type
INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not
More informationALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential
More informationSelf-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.
Process Pump Series 3/5 Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted
More informationModel GP PRESSURE REDUCING VALVE Installation & Operation Manual
Model GP-2000 PRESSURE REDUCING VALVE Installation & Operation Manual Please read this bulletin thoroughly before using the pressure reducing valve, so that you may do so correctly and safely. Please carefully
More informationAir Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.
Air Saving Valve Series R Pressure Valve Series Q Flow Valve P r.9.7 2..3.1 D -FE KE -FG -FP -FM.1.2.2.3 pressure (MPa) -D -T P ow valve Fl N AQ V e n by o i t p nsum n stroke o c r i r a Cuts g the retu
More informationProcess Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order
Process Pump /5 Series Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted areas.
More informationUCA2 Series. Bore size: 10, 16, 25, 32. UCA2 UCA2-L (with switch) Double acting Compressed air to 60 (no freezing)
SCP* CMK CM SC CKV C/OV CT MDC SMD JSK/M U STR SRL SM RCC Specifications Descriptions Bore size mm ctuation Working fluid Max. working pressure MPa Min. working pressure MPa Withstanding pressure MPa mbient
More informationSeries SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100
Clean Air Filter Variations SFD SFD SFD SFD Made to Order Type Disposable (non-replaceable element) Cartridge (replaceable element) Flow rate L/min (ANR) (at inlet pressure.7 MPa) Up to 6 Up to 8 Up to
More informationPosition locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to
RV* FH1 G G B FH Specifications Descriptions Cylinder bore size Working fluid Max. working pressure Min. working pressure Ambient temperature Port size Operational stroke length Rod diameter Capacity of
More informationCKL2 Series. Powerful chuck. Operational stroke length: 5, 6, 8, 10, 12, 16, 20, 23mm. Specifications. Switch specifications
RV* FH1 G B FH G A S Specifications Descriptions Size Cylinder bore size mm Working fluid Max. working pressure MPa Min. working pressure MPa Ambient temperature C Port size Operational stroke length mm
More informationPrecision Regulator. Series Model Regulating pressure range Port size Page
Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.
More information/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651
/ Air Line Kit AL - M1202 / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651 002 1 Thank you for purchasing the Air Line Kit " AL - M1202 ". This Air Line Kit is designed to adjust the air supply
More informationProcess Pump. Series PAF3000/Series PAF5000
Process Pump Series 3/Series The excellent corrosion resistance is achieved due to the new PFA wetted material construction! PPS/PFA dual construction, withstand pressure and heat cycle performance have
More informationTechnical Data Sheet TI-F50 Locking Units series KFH
English translation of German original Locking Units series KF Further important practical advice is given in Operating Manual BA-F50., Rod diameter 18 mm 50 mm øz 8 L 2 6 x 6 0 min. 4x30 KF 18 to KF 32,
More informationOperation Manual Air Saver Unit ASV5000 Series
9IM-V066-b Operation Manual Air Saver Unit ASV5000 Series Thank you for your choice of Kuroda Pneumatics LTDs product on this time. Please read this operation manual carefully and use the product correctly.
More informationProcess Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example
Process Pump Series 3/5 Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation No sliding parts in wetted
More informationProcess Pump. PAF3000 Series/PAF5000 Series
Process Pump PAF3 Series/PAF Series RoHS The excellent corrosion resistance is achieved due to the new PFA wetted material construction! PPS/PFA dual construction, withstand pressure and heat cycle performance
More informationfor Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity)
for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity This is a Pilot operated pressure reducing valve. It is suitable to install in the steam lines with the
More informationStandard Specifications
NARM, 2 Ways of Connection Small Size Pressure Gauge ø5mm Reverse flow function available on the standard model Space Saving -B2 NARM-6A-NG Standard Specifications Fluid Proof pressure psig (MPa) Max.
More informationSeries IRV1000/2000/3000
CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one
More informationFH500 Series. Open and close angle: 20 at open, -5 at closed. FH510-D FH512-D FH516-D FH520-D FH510-O FH512-O FH516-O FH520-O Actuation.
RV* FH G G FH G N/ S/F Specifications Double acting/single acting FH Series Open and close angle: at open, - at closed FH FH-D FH-D FH-D FH-D FH-O FH-O FH-O FH-O Actuation Double acting Single acting Working
More informationRP series Rotor Pumps
ontact etails RP series Rotor Pumps Nomenclature Features Low noise Substantial reduction of the operation noise, by to db (comparison with aikin products), and improved sound quality are achieved by adopting
More informationALF400 to 900, ALT-5/-9
uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa 0. MPa.0 MPa (Note
More informationFLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:
FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed
More informationModel GP-1000 Series PRESSURE REDUCING VALVE. Installation & Operation Manual
Model GP-1000 Series PRESSURE REDUCING VALVE Installation & Operation Manual Please read this bulletin thoroughly before using the pressure reducing valve, so that you may do so correctly and safely. Please
More informationDiscontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.
Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing
More informationPressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5.
Series 17 Pressure booster Page General Pressure boosters ø 4 Pressure boosters ø 4 c/w air pressure regulator Pressure booster ø 63 Pressure booster ø 63 c/w air pressure regulator Pressure booster ø
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 9 ACCUMULATORS The material needed for outcome 2 is very extensive so there are
More informationFOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM
IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY
More informationModel GPR Primary Pressure Regulating Valve. Instruction Manual
Model GPR-2000 Primary Pressure Regulating Valve Instruction Manual Please read this instruction manual thoroughly before using the primary pressure regulating valve, so that you may do so correctly and
More informationMounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators
Supply Pressure Regulator Type 4708 Type 4708-5352 on Type 3730 Positioner Type 4708-52 with filter receptacle Type 4708-6252 on Type 3372 ctuator Fig. Supply pressure regulators Mounting and Operating
More informationRelated Products: Auto Drain Valve. Model/Specifications. Model
Related Products: Auto Drain Valve /600 Drainage is automatically discharged in a reliable manner, without requiring human operators. Highly resistant to dust and corrosion, operates reliably, and a bowl
More informationSUPER PRECISION AIR RELAYS
CAT. No. KS-128E SUPER PRECISION AIR REGULATOR rsseries SUPER PRECISION AIR REGULATORS rr SERIES SUPER PRECISION AIR RELAYS Air Pressure Regulators that attain the ultimate in pressure control. S/R R SUPER
More informationLow torque Metal seal type Rotary joint
CAT.E0- A Low torque Metal seal type Rotary joint Long Life 0. to billion rotations Under SMC s life test conditions. Flexible Coupling Fixed (Body) Low rotational torque 0.00 to 0.0 N.m or less Rotary
More informationFLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:
FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed for outcome
More informationLMU100/200 Series. Standard Specifications
Mist Spray Unit MU/ Series Intermittent spray to cutting and press gear chains, etc. Standard Specifications Inlet air Oil tank set range Oil Dynamic viscosity of oil ( C) Oil tank capacity (cm ) mbient
More information30T A/Manual Hydraulic Shop Press
30T A/Manual Hydraulic Shop Press Operation Manual 1 1. Important Information 1.1 Safety Information 1.1.1 Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when
More informationMODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL
MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL Index 1. List of components / General arrangement 2. Description 3. Handling 4. Installation 5. Actuators / Operation 6. Maintenance a. Changing
More informationInstallation, Operation and Maintenance Manual for Back Pressure Regulator
Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN
More informationCompact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ
Compact Regulator 2 Series 2. MPa compatible, piston type compact regulator V SR X AP1 Compatible with inlet supply pressure of 2. MPa Employs a knob shape for easy operation Compact type (face to face
More informationPush-In Fitting Type Silencer
http://www.pisco.co.jp CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type 540 Reduce Exhaust Noise from Exhaust Port. Excellent Silencing Effect. Selection from 3 types. Push-In Fitting
More informationRegulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2
Regulator: Modular Type with ack flow Mechanism R3 to 6 How to Order Regulator with a built-in mechanism that ensures a quick release of the outlet air pressure (built-in check valve with back flow mechanism).
More informationARI-DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP
ARI-DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 ARI-DP32 / DP33 Pneumatic actuator Page 2 DP-Actuator Extended stem on air failure ARI-DP34 Pneumatic actuator Page 2 ARI-DP34T Pneumatic actuator Page 6
More informationAir preparation units
Overview Description Page Characteristics Dimensions Order instructions Type overview unit three-piece 44, 45, 48 52 6 unit two piece 44, 45, 48 52 6 Filter-regulator 44, 45, 48 53 6 Filter-water-separator
More informationALF400 to 900, ALT-5/-9
uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa Max. operating pressure
More informationRegulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K
Modular Type Regulator Series R Regulator Series R Model R M5 x.8 ccessory R2 /8, /4 R /4, 3/8 R3 /4, 3/8 R4 /4, 3/8, /2 Pages 36 through 4 Regulator with back flow mechanism Series RK R4-6 R5 R6 R2K RK
More informationREPAIR PART NUMBER NUMBER DESCRIPTION 0137 ELE 0136 ELE 12 VOLT SOLENOID
PART REPAIR PART NUMBER NUMBER DESCRIPTION 0137 ELE 0136 ELE 12 VOLT SOLENOID 0203 WHL 0250 WHL WHEEL HUB 0251 WHL AXLE 0252 WHL DUST CAPS 0253 WHL TIRE - 210 SP 0204 WHL 0211 WHL TIRE & WHEEL - SP 0250
More informationRegulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K
Modular Type Regulator Series R Regulator Series R Model R M5 x.8 ccessory R2 /8, /4 R /4, 3/8 R3 /4, 3/8 R4 /4, 3/8, /2 Pages 36 through 4 Regulator with back flow mechanism Series RK R4-6 R5 R6 R2K RK,
More informationWide opening parallel grippers Series CGLN
CATALOGUE > s 202 Wide opening parallel grippers Series CGLN > Grippers Series CGLN Magnetic Sizes: ø 0-6 - 20-25 - 32 mm» High flexibility during mounting» High grip force» Rack and pinion synchronized
More informationAMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life
Water Separator Series AMG Can remove water droplets in compressed air. Use this product in cases where water must be avoided, but not so dry as when an air dryer is used. Through the adoption of an element
More informationCompressed Air Cleaning Filter Series
Compressed ir Cleaning Filter Series M /FF Series For Water Droplet, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the
More informationOWNER S TECHNICAL MANUAL
EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,
More informationLeak free Pipe Rupture Valve for Excavators
Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................
More informationHand lever valves VHER
Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:
More informationVPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10
/ ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications
More informationPressure Reducing Valve DMV 750 set range: bar
Pressure Reducing Valve DMV 750 set range:.0-6.0 bar Advantage pressure setting possible at any time, also during operation hermetically sealed by valve diaphragm high level of operating safety and long
More informationProcess Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order. Option. Symbol.
Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) Series PAF3 Female threaded PAF31 3 3 Note 1) Actuation Actuation Automatically operated Note
More informationAssembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable
Page 1 von 8 Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV 100-575, top reparable Content Seite 0 Legend 2 1 Overview 2 2 Accumulator assembly and installation
More informationKTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be fully read and understood SECTION 1 - STORAGE 1.1 Preparation and preservation for storage All valves should be properly packed in order to protect the parts
More informationSeries AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use
CAT.ES20-19 A Speed Controller with One-touch Fitting for Clean Room Series AS-FPQ/AS-FPG Series AS-FPG Series AS-FPQ Speed controllers for clean room use AS-FPQ: Brass (electroless nickel plated) and
More informationSmooth Vent Valve. XVD Series
Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the
More information2 in. 18 Gauge Brad Nailer. User manual
8504342 2 in. 18 Gauge Brad Nailer User manual Technical Data Capacity....100pcs Nail length... 15-50mm( 5/8-2 ) Fastener size....18gauge (1.25 1.00mm) Operation pressure 70-110PSI(4.8-7.5bar) Air inlet....1/4
More informationPressure Reducing Valve DMV 755
Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to
More informationCautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the
The Silencer, connected to the exhaust port of a device, suppresses the exhaust noise. The Silencer displays an excellent noise suppression effect. Three types are available for your selection. The element
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete
More informationClean Speed Controller with One-touch Fitting
Clean Speed Controller with One-touch Fitting Series -FPQ/-FPG -FPG Series -FPQ Series Speed controllers for clean room use S R -FPQ: (electroless nickel plated) and -FPG: are now available as a series.
More information24 Litre Air Compressor
Operator s Manual 24 Litre Air Compressor WARNING! Before using this appliance, read the Operator s manual and follow all its safety rules and instructions. SPECIFICATION Model Power ITEM DATA HWKAC2 1Kw/1.5HP&1.5Kw/2HP&1.8Kw/2.5HP
More informationVBA1110 to 4200 VBA /4 (IN/OUT) 1/4
Booster Regulator to 4200 Specifications Pressure increase ratio Max. supply pressure Set pressure range Ambient and fluid temperature Lubrication Installation Pressure adjustable mechanism -02 Fluid Proof
More information(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type
These are air finger models featuring light weight and miniature size. Blank fingers are available for the K type fingers as option. R-guide leaves no possibility of misalignment. The blank finger can
More information30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.
Silencer The M silencer is now added! Space saving New RoHS ctual size 6. mm mm Fingertip size The resin silencer is now a more compact size! Existing model Entire length reduced by up to 30% (SMC comparison)
More informationPrecision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.
Precision Regulator //3 Series Basic Type Air Operated Type Series Model Set pressure range Port size Page Series Series 3 Series 3 3 3 Series 3 Series 3.5 to MPa. to MPa. to.8 MPa /8 8.5 to MPa. to MPa.
More informationOPERATING AND MAINTENANCE MANUAL
Series 4300 Engineered Performance TABLE OF CONTENTS 0 INTRODUCTION 1 1 Scope 1 2 Description 1 3 Specifications 1 0 INSTALLATION 1 1 Mounting 1 2 Piping 1 1 Connecting Process Pressure 2 2 Vent Connections
More informationPressure reducing valve, pilot operated
Pressure reducing valve, pilot operated RE 26928/09.07 Replaces: 10.97 1/8 Type 3DR Size 16 Component series 5X Maximum operating pressure 250 bar Maximum flow 220 l/min H5844 Table of contents Content
More informationHANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:
HANDBOOK Squeeze Off Unit SOU 400 Please refer any queries to: Hy Ram Engineering Co Ltd Pelham Street Mansfield Nottinghamshire NG18 2EY Telephone No: (01623) 422982 Please note all queries should state
More informationHand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.
http://www.pisco.co.jp VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Hand Valve Series 556 Control Open/Close for Air Supply. Release Residual
More informationAuxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998
Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated
More informationSUPER PRECISION AIR RELAYS
CAT. No. KS-128E SUPER PRECISION AIR REGULATOR rsseries SUPER PRECISION AIR REGULATORS rrseries SUPER PRECISION AIR RELAYS Air Pressure Regulators that attain the ultimate in pressure control. SUPER PRECISION
More informationFlanged pressure reducer/stabilizer VRCD
Flanged pressure reducer/stabilizer VRCD 2 This unit reduces and stabilizes the upstream pressure by operating on its load losses with a constant downstream pressure irrespective of the rate of flow value.
More informationTECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH
TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT CAUTION!
More informationSmooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV
Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the
More informationSIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information
SIX R431006322 (P -063892-00001) AND SEVEN R431006321 (P -063981--00002) POSITION CYLINDERS Service Information The six and seven position cylinders are medium duty pneumatic positioning devices that operate
More informationSPCH/ Blowing block
> > for linear stretch blow moulding machines > > Compact and safe design > > Best suited for PET bottles up to litres, depending on cycle time Technical features Medium: Compressed air (purity class 3..3
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional
More informationPowers Controls D Day-Night Thermostats
Powers Controls D Day-Night Thermostats Technical Instructions Document No. 155-073P25 TH 832-2 Description The D Day-Night or Two Temperature Thermostat is available as a room-type instrument. It is essentially
More informationData sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119
Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,
More information