TS1. Ultrasonic Tank Sender. Installation and Operating Instructions. For TS1 Firmware v3.8. Page 1 INST-TS1-V13 18/11/10

Similar documents
Ultrasonic Fuel Level Sensor - UFLS

Ultrasonic level transmitter and indicator

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Expert Hydrostatic Level Transmitters

User s Manual. Revision 1.2. Copyright 2010 Maretron, LLP All Rights Reserved

Electro Controls. Level WattsIndustries.co.uk

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

200A Series ELECTRONIC LEVEL TRANSMITTER

INTRODUCTION TO NETWORK WIND 3 MOUNTING THE UNIT 14 SELECTING THE DISPLAY MODE 5 ABBREVIATIONS AND DEFINITIONS 17

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Sondaloop and MiniSonda Version 2 Ultrasonic Level Transmitter

Installation, operating and maintenance Instructions for Seemag bypass level indicator

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

LS-UT Ultrasonic Level Transmitter

Level MEASUREMENT 1/2016

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

Preferred Instruments Danbury, CT USA

CentriFlow Meter Integrated Air Entrainment System

Thanks for choosing EJAI SOLAR product

Engineering Data Sheet

Unit 1, Fullerton Road Rotherham S60 1DJ. Tele: Fax:

Installing a Probe. Typical Installation

GUMMIKOMPENSATOR GKF8000 / GKF8130

How to specify a product. Process Sensors and Mechanical Instruments

RAI-M series RUDDER ANGLE INDICATOR SYSTEM

INSTRUCTION MANUAL. process. Ultrasonic Flowmeter Range

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Materials : Galvanized steel flanges

INSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK

Materials : Electro galvanized steel flanges

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

CKL2 Series. Powerful chuck. Operational stroke length: 5, 6, 8, 10, 12, 16, 20, 23mm. Specifications. Switch specifications

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

PyroCouple Series Operators Guide

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

IMPORTANT SAFETY INSTRUCTIONS

Pressure transmitters EMP 2

Electro-Pneumatic Converter YT-940 SERIES

L21S/SR/ST Glass Level Gauges

OUS31. Technical Information

Air Eliminators and Combination Air Eliminators Strainers

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

EXH. Specifications. Descriptions. Min. working pressure MPa

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

100C Air Compressor Kit

Operation Manual Air Saver Unit ASV5000 Series

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

UsER manual for Watersens ph -REDOX

FTC130 Transmitter. Operating Manual

Model MTB-ASME Vertical Bladder Tanks

Materials : Dichromate zinc plated steel flanges or AISI 316

200 PSI COMPRESSORS - MODEL NUMBERS

Model MTB-ASME Vertical Bladder Tanks

Mass Flow Controller (MFC) for Gases

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

INSTRUCTION MANUAL Pressure Relief Device LPT

INSTALLATION GUIDELINES

Installation, Operation and Maintenance Manual for Back Pressure Regulator

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

Precision Liquid Settlement Array Manual

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

Presents the following instructional slide show:

MODEL WEIGH MODULE

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

3M Electrial Markets Division EMS. Electronic Marker System

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

Malema Sensors M-2700 Integrated Ultrasonic Flow Meter

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Cable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.

Mass Flow Controller (MFC) for Gases

DTG - LCD Digital Temperature Gauge USER MANUAL

GUKO FDA. einfach. gut. beraten.

Gas density monitor With integrated transmitter Model GDM-100-TI

Electropneumatic Transducer (I/P) Installation, Operation and

ALF400 to 900, ALT-5/-9

Size : Ends : Min Temperature : Max Temperature : Materials : Galvanized steel flanges

GILMONT ACCUCAL FLOWMETERS

Pressure Measurement Single-range transmitters for general applications

Liquid level instruments BM 24 /BM 51

Float Operated Level Controllers

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

MSC Guidelines for Vents, Fills and Sounds

Tapped Hole (.375) Tapped hole 15 (.594) (.391±.004) Frame 19±0.2 (.750±.008) 12.7±0.2 (.500±.008) 19±0.2 (.750±.008) R S 4 x Ø 5.4 (.

I/P Transducer Positioner Module

Model MTB-ASME Horizontal Bladder Tanks

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Horizontal Bladder Tanks

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

LIQUID LEVEL GAUGE FOR WELDING ZGAU 716 O&M, 717 O&M, 718 O&M, 719 O&M

MANUAL. Sesame. Thermoplastic Tank Technologies

VK/VP SERIES : Sealless Vertical Pump. Assembling Instructions 2010

Transcription:

TS1 Ultrasonic Tank Sender Installation and Operating Instructions For TS1 Firmware v3.8 Page 1

Table of Contents 1. FEATURES... 3 2. SPECIFICATIONS... 3 3. DIMENSIONS... 4 4. MOUNTING AND INSTALLATION... 5 5. WIRING... 9 6. PROGRAMMING AND SETUP... 10 7. PROBLEM SOLVING... 10 8. FREQUENTLY ASKED QUESTIONS... 11 Important TS1 Installation Issues 1. The sender must not be mounted closer than 150mm from the centre of the sender to sides of the tank, baffles or other intrusions. 2. Only use on tanks greater than 200mm in depth. 3. Sender must be mounted parallel to the surface of the liquid. 4. Do not install on flexible tanks that may bulge/distort as fluid levels change. 5. Check unit is calibrated to suit tank shape, depth and fluid type. 6. Make sure that sender protrusion is NOT in contact with any object including sealants when mounted. 7. Use gasket and fittings as provided. 8. Mount above deepest point of the tank. Page 2

1. Features 12V and 24V operation Extremely low profile only 20mm high once mounted Operating distance of 0mm to 2000mm maximum Programmable tank dimensions via windows application Linear and non linear tank calibration at 5 levels Supports metal and plastic tanks Supports tanks wall thickness up to 6mm (or larger if spacer is used and top limit adjusted) Industry standard SAE-5 stud mounting pattern with gasket seal and washers. Supports analogue gauge types 10-180, 300-10, 240-33 Supports Digital meter that require 0-5 volt inputs Operating temperature range of 4 c to 65 c 2. Specifications Electrical 10V MIN to 32V MAX DC. Ignition protected to ISO 8846 Fire Resistance tested to ABYC, US Coast guard and ISO10088 Output types: Analogue 10-180, 300-10, 240-33 ohm gauges and 0-5volt Environmental Resistant to Petrol, Diesel, Water, and Chemical Toilet. Maximum Tank depths Operating distance of 0mm to 1100mm for Petrol tanks Operating distance of 0mm to 2000mm for Water tanks Operating distance of 0mm to 2000mm for Diesel tanks Operating distance of 0mm to 1500mm at 55 c Note: Liquids that may have a sound absorbing surface will limit tank depth or in the worst case provide no return signal eg. foam bubbles or porous sludge. Permanent liquid surfaces that are more than 3 degree s off level will have a tank depth derating effect. Liquids that have higher viscosities than water (e.g. oil) may not propagate liquid ripples that create a strong return signal. This will also have a tank depth de-rating effect. Don t use on tanks shallower than 200mm in depth as angular reflections will reduce accuracy. Page 3

3. Dimensions 19.64 [3/4"] 95.35 [3 3/4"] ACOUSTIC PROTRUSION 8.9 [3/8"] 95.35 [3 3/4"] 84.88 [3 5/16"] Page 4

4. Mounting and Installation 68 Ø5 [Ø3/16"] 72 Ø42 [Ø1 5/8"] 80 R27 [R1 1/16"] VERY IMPORTANT: DIAMETER MUST NOT BE LESS THAN Ø42mm 68 72 INDICATES CUTOUT GASKET TANK LID 4.5mm ACOUSTIC PROTRUSION TANK LID 4.5mm GLUE BARRIER RING 42mm IMPORTANT SIDE WALLS OF ACOUSTIC PROTRUSION MUST BE NO CLOSER THAN 4.5mm TO THE TANK SIDES OF THE CUTOUT HOLE The acoustic protrusion should be positioned in the tank aperture in the centre of the hole. The protrusion should ideally be protruding into the tank and not be recessed in the hole. See drawing above. For tightening screws ensure base and washers are sitting flat. Tighten screw until screw head makes contact with the washer, and then tighten another 2 full turns. Maximum torque for the mounting screws is 0.5 Newton meter. Note: Drawing is not to scale. Please use the tank gasket as a template and make sure the tank hole is 42mm. Page 5

Case 1 TS1 must be mounted at the deepest tank point! It is recommended the sender is mounted in the middle of the tank, this is particularly important on low or no baffled tanks that are mounted in moving vehicles or vessels. This allows the TS1 to average waves of fluid to the correct level when the depth is varying due to wave slop. Case 2 TS1 must be mounted at least 150mm from a vertical tank baffle, tank walls and piping. Page 6

Case 3 Correct BEP Gasket must be used! Use 5 washers provided, washers must be placed under screw heads to prevent rubber lid damage. Case 4 Acoustic protrusion must not touch the tank frame! Case 5 TS1 must be mounted so it can see the bottom of the tank if the liquid is to be measured to the bottom. Page 7

Case 6 Inlet and Outlet piping must go in at least ⅔rds of the way in to the tank on grey and black water tanks to stop water turbulence when filling. Case 7 Do not fit the TS1 with a tube. Case 8 Ensure bolts and mounting holes are aligned properly to keep plastic body isolated acoustically from tank. Do not over tighten the screws. Page 8

5. Wiring Power must be removed before TS1 is connected to the system. Ensure wiring is correct or else damage may occur rendering the device inoperable. + - 12V + - 12V NEG BAR NEG BAR POS BAR POS BAR OUTPUT (GREEN) POS (RED) NEG (BLACK) G (S) OUTPUT (GREEN) NEG (BLACK) POS (RED) USE 24V RATED GAUGES FOR 24V SYSTEMS (GAUGE SHOULD HAVE DROPPING RESISTOR) Page 9

6. Programming and Setup TS1 Tank Sender (BEP P/N TS1) Interface Box + USB-to-Serial Converter Cable (BEP P/N TS1-PK) Computer with USB Port Please visit the BEP website for the programming software. 7. Problem Solving Water Tanks After long periods of no use, condensation will build up on the roof of the water tank and the sender face. If the water droplets are large, the sender will not be able to read the contents of the tank accurately. This will clear with normal boat or RV use. Waste Tanks Large amounts of foam bubble on the surface of the liquid caused by detergents or washing powders will result in the sender not receiving reflected sound pulses back from the liquid surface, instead these will be absorbed by the bubbles until they disperse. Then normal operation will resume. Page 10

8. Frequently Asked Questions Q: What is the signal update period? A: Signal is updated in real time. Q: Why is the tank level stuck on one value? A: When the sender cannot measure a valid tank level, the sender will recover the last good reading of the tank level from its own memory. This will be sent to the monitor until a new valid level is found. Q: Is the TS1 ignition protected? A: The TS1 is ignition protected and approved. It is fully potted. Q: On power up, the analogue gauge goes full scale then back to empty. After 5 seconds it shows the correct level. A: This is normal for a 10 180ohm analogue gauge. Q: On power up, the analogue gauge goes full scale and then back to the correct level. A: This is normal for a 240 33ohm analogue gauge. Q: The gauge is reading full all the time. A: 1. The most common problem is that the acoustic protrusion is touching the tank. 2. The incorrect gasket has been used specified gasket is a Cork/viton mix. 3. The sender is to close to the side of the tank. 4. There is an obstruction in the tank. 5. The mounting screws are not isolated acoustically from body (see. Case 8) Q: Is the sender sensitive to electrical interference. Should we use shielded cable? A: There is no need to use shielded cable, unless you are running a long distance and near appliance cables that radiate noise. Q: What is the maximum distance between sender and meter? A: 50 metres. Q: What support is there for the product? A: Updates will be placed on BEP website. Q: Why is the meter reading incorrect when tank is empty? A: There must be some fluid covering the bottom of the tank for sender to receive a valid return signal. Q: What is the beam angle of the sender? A: 300mm at 2M depth Q: Can I use a sealant with the TS1 and gasket A: Yes, but ensure sealant does not get on to protrusion. Also, do not over tighten screws for purpose of providing a tighter seal. The screws should be tightened until there is contact between screw head and washer, then another 2 full turns. Page 11

BEP MARINE 55 Paul Matthews Road, Albany, Auckland 0632 New Zealand PO Box 101739 NSMC Phone (+649)4157261 Fax. (+649)4159327 www.bepmarine.com E-mail: enquiries@bepmarine.com Please visit our website for the latest International Distributor List Page 12