Data Sheet. Vacuum generators

Similar documents
Pilot Check Valve: Metal Body Type

SPCH/ Blowing block

Air Saving Valve. Pressure Valve Flow Valve

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

VACUUM REGULATORS CONTENTS

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Series ZL. Multistage Ejector. New models! ZL212 large flow rate type and ZL112 with valve. ZX ZR ZM ZY ZH ZU ZL ZF ZP ZCU

Air Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.

Multistage Ejector Series ZL

Multistage Ejector Series ZL

OWNER S TECHNICAL MANUAL

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

4/2 way Pneumatic Solenoid Valve

ALF400 to 900, ALT-5/-9

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Direct Operated Precision Regulator Modular Style. Standard Specifications

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Pneumatic valve islands

Precision Regulator. Series Model Regulating pressure range Port size Page

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Series IRV1000/2000/3000

SOLENOID VALVES AND PNEUMATIC VALVES

Compact Pressure Switch

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Slit Valve. XGT Series. Low particle generation. With end lock mechanism. Service life of two million cycles. XLA XL XL Q D- XSA XVD XGT CYV

// ADapters GUIDelines

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

F l o w c o n T R o l v a l v E S

LMU100/200 Series. Standard Specifications

WARNING. Work drop prevention check valves FPV series. Vacuum accessories. Safety handling of workpiece with several pads

ALF400 to 900, ALT-5/-9

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

SECTION 11 VACUUM GRIPPER

Piloted Non-Return Valves

Pressure decay sensor Pressure decay sensor Flow at 90 psi (6 bars) Tripping point at 90 psi (6 bar) supply Connection Mechanical life Relay C

OPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson

Smooth Vent Valve XVD. Series

Coiling Tube with Twist-Proof Fitting

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Smooth Vent Valve. XVD Series

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Standard style

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

Precision and Instrument Regulators 1/4" port size

Pneumatic spool valve islands

Series MX pressure regulators 3/

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Operation Manual Air Saver Unit ASV5000 Series

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Specifications. JIS Symbol 2 port valve 3 port valve (A) 2 (A) 2. Construction. 2 port valve/series VHK2 3 port valve/series VHK3.

ALF400 to 900, ALT-5/-9

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV

Standard Specifications

Process Pump. PAF3000 Series/PAF5000 Series

Spool compact valves pilot and solenoid actuated G 1/8 - G 1/4

Plant, components and devices for very high and high pressures (7000 bar and over)

GM Series Dual-Block Multi-Function Gas Control Valves

Process Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

Space Saving Vacuum Ejector & Vacuum Pump System

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

1200 Series Pressure Regulators

VALVES ISO 5599/1, SERIES IPV-ISV

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

Manual Actuated Boiler Blowdown Valves

Air preparation units

PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

Booster Regulator/Air Tank

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Nugget 120 V14 Series

Electro Controls. Pressure WattsIndustries.co.uk

VERTICAL BLADDER TANK

Compressed Air Cleaning Filter Series

Flow control valves Series RFU - RFO 2/

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

[Graphic Division] 10

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

RR 16 Commercial & Industrial Regulator

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

Pressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5.

RR 16 Commercial & Industrial Regulator

Air Differentail Pressure Switch

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Pressure Independent Control Series

Proportional Throttle Cartridges, Size 16

CKL2 Series. Powerful chuck. Operational stroke length: 5, 6, 8, 10, 12, 16, 20, 23mm. Specifications. Switch specifications

Position locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Description Total stroke Maximum Recommended Page in mm gripping force in N workpiece weight in kg

Transcription:

Data Pack G Issued March 1997 1502323721 Data Sheet Vacuum generators Specifications Fluid Air perating pressure range 2.5~6kgf/cm 2 Max. operating pressure 7kgf/cm 2 perating temperature range 5~60 C Lubrication Not advised Max. suction flow rate/air consumption unit (Nl/min) Max. vacuum pressure Nozzle diameter mmø Specifications mmhg (Torr) 0.5 0.7 1.0 1.3 Max. suction flow rate 660 (0) 5 12 24 40 660 (0) 20 34 68 *At 4.5kgf/cm 2 Standard box type generators A range of light compact boxed vacuum generators with built-in silencers. These units are compact and lightweight for easy mounting to mobile units. The RS range includes units with nozzle diameters from 0.5 to 1.3mm. Construction SUP. Cassette Seal Generator symbol Cover Diffuser ass'y Body Sound absorption material Cover VAC. Box type (Built-in silencer) General precautions for all vacuum generators Air supply side circuit It is necessary to design appropriate sized piping on air supply side circuit to be in line with the air consumption of each generator. The effective orifice area of tubes, fittings, valves etc. should be large enough to prevent suction flow from pressure drop. Also it is necessary to ensure the air source is sufficient to allow for maximum air consumption of generator and air consumption circuit. A filter and unlubricated air supply to the generator is recommended for maximum performance. Vacuum side circuit Piping between generator and pad etc. should be kept as short as possible to prevent it from unnecessary delay and leakage. Number of pads ne pad per generator is the general rule. If using two or more pads, they must be seated correctly to avoid leakage. Selecting nozzle diameter Selection depends on suction flow rate requirements. Points to consider: 1. Volume of air to be evacuated in Nl/min 2. Porosity of component. If porosity is large a larger nozzle diameter should be selected 3. should be considered to maximise efficiency. Exhaust At least one exhaust should be left open.

Exhaust characteristics/flow characteristics Flow characteristics: at 4.5kgf/cm 2 supply air pressure Max. vacuum pressure: 660mmHG (0 Torr) 0.5mm nozzle diameter (RS stock no. 725-2) Exhaust characteristics Flow characteristics 0.7mm nozzle diameter (RS stock no. 725-226) Suction flow rate Exhaust characteristics Suction flow rate 20 0 20 Nl /min Nl /min 0 2 4 6 8 Flow characteristics ne touch fittings/vacuum specifications Specifications perating vacuum pressure Torr~ Note 1) Leakage -5 cm 3 atm/sec max. Ambient and fluid temperature 5~60 C Note 1) Leakage per one fitting when tube is connected. When connecting tube, the state of connection should exceed minimum bending radius. Applicable tube Material Note 2).D. Note 2) Accuracy of tube diameter The accuracy of tube diameter should be as follows. Nylon tube, Soft nylon tube: ±0.1mm Polyurethane tube: ±0.15/-0.2mm Nylon, Soft nylon, Polyurethane ø6, ø8, ø Precautions RS tubing can be used with vacuum, and will withstand vacuum pressures in excess of 700mm Hg. Conventional compressed air fittings should not be used with vacuum. The fittings incorporated with the RS vacuum equipment are suitable for vacuum. Combination vacuum generator 0 0 5 15 20 1.0mm nozzle diameter (RS stock no. 725-232) Exhaust characteristics Flow characteristics 1.3mm nozzle diameter (RS stock no. 725-248) Suction flow rate Exhaust characteristics Suction flow rate 25 0 0 50 0 50 Nl /min Nl /min 0 20 30 40 50 Flow characteristics 0 20 40 60 80 An all in one vacuum generator, silencer, suction filter incorporating an on/off air supply valve. This valve switches the air supply and therefore vacuum on or off via the in-built solenoid. Additionally the unit has a vacuum release (blow-off) valve. This valve switches a positive pressure to quickly release the object being picked. An integral flow control valve provides adjustment to the rate of flow of air used to release the object. The generator has a nozzle diameter of 1.2mm and incorporates a 1 8 BSP inlet port and two 1 8 BSP outlet vacuum ports. Also included with each unit is a range of fittings for connection to 6mm or 8mm diameter tubing (all 6 fittings are suitable for use with both positive pressure and for use with vacuum). A blanking plug is also included for situations where only one vacuum port is required. The combination generator incorporates a two stage nozzle system to increase suction flow. 2

2-stage nozzle system 2-stage nozzle system increases suction flow increase System circuit (including optional vacuum switch) Q Q First diffuser nozzle Second diffuser nozzle Q Q Suction flow 40% Suction flow increase Vacuum switch Generator characteristics standard supply pressure of 5kgf/cm 2 Specifications Fluid Air Max. operating pressure 7kgf/cm 2 Working pressure 2~5.5kgf/cm 2 perating temperature 5~50 C (with valve) perating valve (air supply and release valve) Main (in body) poppet valve Pilot valve solenoid valve Vacuum switch (option) Diaphragm type switch RS stock no. 725-305 Suction filter 30µm, PE (polyethylene) Valve specifications perating method Pilot operated Main valve type Rubber poppet Effective area (Cv factor) 3mm 2 (0.17) perating pressure 2.5~7kgf/cm 2 Rated coil voltage* 24Vdc Power consumption* 1W Electrical entry* Plug connector Max. cycle time 5 times/sec *Applicable to pilot valves. Vacuum switch specifications Sensor type Diaphragm mechanism Switch type Contact (reed switch) Pressure range 200~ 600mm Hg Differential Max. 150mm Hg Supply voltage dc12~26v ac24~0v Indicator light Lighting under N condition Max. pressure 5kgf/cm 2 Wire 2 wire Maximum vacuum pressure mmhg Max. vacuum pressure Max. suction flow rate 70 60 50 40 30 20 Maximum suction flow rate Nl /min air consumption Nl /min 3

Construction/Parts list Vacuum release valve Pilot valve Vacuum release flow control needle valve Air supply port Filter cover 4 ass'y 12 11 Air supply valve 3 13 Adaptor plate Poppet valve ass'y 2 1 6 5 Valve cover Body Diffuser ass'y Cover 14 Vacuum switch Contact protection Diaphragm type switches have no built-in contact protection circuit. A suitable protection device should be used when using 5m or more lead wire length, and 0Vac. See Suppressors/Filter Shielding section of the current RS catalogue. perating instructions switch adjustment Diaphragm switch adjustment Tension 8 bolt Vacuum port Suction filter 7 9 Silencer ass'y Check valve No. Name Material ❶ Body Aluminium diecast ❷ Valve cover Aluminium diecast ❸ Adaptor plate Aluminium diecast ❹ Filter cover assembly ❺ Cover Zinc diecast ❻ Diffuser assembly ❼ Suction filter Polyethylene ❽ Tension bolt Stainless steel ❾ Silencer assembly ❿ Check valve NBR (Nitrile Butyl Rubber) 11 12 13 14 Release flow rate control screw Pilot valve Poppet valve assembly Vacuum switch Vacuum switch specifications Reed switch Red Black Stainless steel Reed switch contact: RS stock no. 725-305 Max. switching current : 0mA at 30Vdc 5-20mA at 0Vac Max power : 2 watts There is a slotted adjuster on top of the vacuum switch for setting actuation vacuum pressure levels. Precautions How to operate generator with valve When the pilot valve for air supply is on, air flows to diffuser assembly and vacuum is generated. When the pilot valve for vacuum break is on, air flows into vacuum port and vacuum is rapidly broken. Vacuum breaking speed is controlled by the flow control screw. When the air supply valve is off, air counterflows from silencer by atmospheric pressure and vacuum is broken. However, vacuum break valve should be used to ensure broken vacuum. Notes Adjusting the vacuum release Vacuum release air flow rate is adjusted by vacuum release flow rate control screw. Cleaning the suction filter Check filter at regular intervals, if necessary remove and clean with soapy water. Installing the silencer Install the internal silencer so that the open vanes are towards the vacuum port side and be sure there are no obstructions blocking the exhaust flow. To change the orientation of the silencer push the unit out of the generator body, turn it over and push the silencer back into generator body. 4

Mounting direction of silencer Rubber/Material and characteristics Diffuser window Vacuum pads How to calculate lift force By means of equation W: Lift force (kgf) P: (mmhg) S: area (cm 2 ) t: Safety rate Horizontal lift: 1 2 Vertical lift: 1 4 W= P S t (1.033) 760 Table of theoretical lift force Theoretical lift force (kgf) = P S t (1.033) 760 W Horizontal lift W Vertical lift Avoid it unless otherwise needed ( ) Material Nitrile rubber Item NBR Tensile strength Elongation il-proof (gasoline) il-proof (Benzol) Solvent proof (Toluene) Solvent proof (Alcohol) Weather-proof zone-proof Heat-proof Cold-proof Wear-proof Burst-proof Water-proof (Water) Little or no influence Good and strong subject to conditions Not compatible Note. The above table covers only general characteristics of rubber subject to change depending upon the application conditions. How to calculate response time Approximate response time upon the time of suction will be worked out by following the equation below. dia. ø Adsorption area (cm 2 ) 0.785 650 0.694 600 0.641 550 0.587 Vacuum 500 0.534 pressure 450 0.483 mmhg 400 0.427 350 0.374 300 0.320 dia. ø16 ø25 ø40 ø50 Adsorption area (cm 2 ) 2.01 4.91 12.6 19.6 650 1.77 4.34 11.1 17.3 600 1.64 4.00.2 16.01 550 1.50 3.67 9.35 14.7 Vacuum 500 1.37 3.34 8.54 13.3 pressure 450 1. 23 3.00 7.69 12.0 mmhg 400 1.09 2.67 6.83.7 350 0.96 2.33 6.00 9.34 300 0.82 2.00 5.12 8.01 Calculation of suction flow rate ❶ Calculation Q1 Generator/Average suction flow rate Q1 = (1 2~ 1 3) Q max. Q max: Generator/Maximum flow rate Nl/min. ❷ Calculation Q2 Piping system/maximum flow rate Q2 = S 11.1 S: Effective orifice area of piping mm 2 ❸ Calculation of response time T1 = V 60 T1= Necessary second to reach final Q vacuum pressure (PV) 63% T2 = 3 T1 Pv 0.95 T2: Necessary second to reach final vacuum pressure (PV) 95% V: Capacity from generator up to pad l Q: Q1 or Q2 whichever smaller *Final vacuum pressure (PV): steady pressure after suction. Final vacuum pressure Pv 0.63 PV 1T 2T 3T 4T Response time 5

Calculation/Example Conditions (Max. vacuum pressure 660mmHg Max. suction rate 24 Nl/min) Tube length 1m tube dia ø8/ø6 dia ø Effective pressure 63% final vacuum pressure Leakage from suction area between work and pad Nil ❶ Q1 Generator/Average suction rate Q1 = (1 2~ 1 3) 24Nl/min = 12-8Nl/min ❷ Piping system/maximum flow rate The following diagram shows effective orifice area corresponding to respective tube length. maintenance The pad is made of rubber and will deteriorate. The rate of deterioration depends upon the application, environment and temperature. Therefore regular maintenance is necessary. s having scratches, cracks, and showing wear should be replaced. Never scratch the surface of the pad. 50 Tube ID Replacement Corresponding effective orifice area mm 2 20 5 3 2 1 ❸ Capacity from generator up to pad V= 1 π D 2 L 00 4 V: Capacityl 8 7.5 6.5 6 5 4.54 3 2.5 2.18 0.5 2 0.3 0.2 0.5 1 2 3 5 20 Tube length m = 1 π (0.6) 2 0 = 0.028l 00 4 D: Tube I.D. cm L: Tube length cm ❹ Response time/calculation Compare generator/average suction flow rate Q1 with piping system/max. flow rate Q2. Q1 (8Nl/min) <Q2 (98Nl/min) consequently Q = 8Nl/min Response time (at 63% of final vacuum pressure) Deteriorated pad How to replace ❶ Pull locking ring up until it comes above pad, then pull pad down to remove and replace pad with new one. (Soapy water can assist removal and replacement.) ❷ Confirm that Lock ring is surely locked into pad. Adaptor Lock ring New pad T1 = V 60 = 0.21= 0.2 sec Q peration guide Safety Vacuum conveyance is, needless to say, to adsorb and convey things to a certain place. The most important thing to be taken into consideration, when designing, is safety. When operating, safety is must and a safety factor should be the first priority when designing. Mounting The standard mounting is horizontal. Slant or perpendicular mounting should be avoided as far as possible unless absolutely necessary. Nevertheless, if unavoidable, it is important to ensure that allowance is large enough to warrant safety. 6

W Horizontal lift W Vertical lift Shock against pad When pushing the pad against work, prevent shock or excessive power which will lead to deformation, cracking or wear of the pad. It is recommended that this force should fall within the range of deformation of the pad skirt or reduce it to such an extent that the rib area touches only slightly. The use of a buffered pad will help alleviate this if necessary. Lifting force, moment, horizontal force When lifting vertically, not only work weight but also acceleration and wind pressure should be taken into consideration. (Refer to illustration ❶.) Keep the moment of work as small as possible since the pad is not moment-proof. (Refer to illustration ❷.) In the case of horizontal movement with a vertical lifting, pad can receive a large force depending upon acceleration. In general, horizontal holding force comes from friction between pad and work. Therefore, when friction between pad and work are low, acceleration or deceleration of horizontal movement should be kept as low as possible. (Refer to illustration ❸.) ❶ Loading by acceleration and wind pressure lifting Take pad s position so that bump may not take place ❷ positioning and work/balance Care should be taken that the suction area of the pad is smaller than the surface of work. therwise vacuum leakage will occur. ❸ Caution against high acceleration and deceleration Caution -work/unsteady distance When pad and work positioning are difficult as in the case of workpieces with differing heights, it is recommended to use a built-in spring type with buffer in order to create a buffer between pad and work. When conveying large surface area plates with multipads, the most important thing is the well balanced positioning of pads, and care should be taken to prevent pads from protruding beyond the plate. Caution 7

Porous workpiece In the case of paper or other porous work, select as small a diameter as possible to lift the work. As a lot of air leakage reduces the suction force, a power increase of the generator, selection of larger effective orifice area of piping lines, or other appropriate counter-measures should be taken Soft work When lifting soft work such as vinyl, paper or thin board, deformation or corrugation of work due to vacuum pressure can occur. In these cases, it is recommendable to use a small pad and to reduce vacuum pressure. Vinyl, paper, etc. Porous workpiece Work-flat plate When lifting a large surface area workpiece such as plate glass, a large force due to wind pressure or shock waves can take place. In these cases, appropriate location or size of pad should be selected. Plate glass etc. type Depending upon the shape and material of work, appropriate type of pad should be selected and used. Vacuum circuit/matching Generator/No. of pads The ideal matching situation is one pad for each generator. If multi-pads are used with only one generator and one pad does not make complete suction, then vacuum pressure will be lost. Subsequently other pads will be unable to complete suction requirement. To remedy this situation each pad should be switched separately and vacuum levels checked with vacuum switches, or put a flow control valve in series with each pad in order that a large leakage does not occur, even if one pad is mispositioned. When using a multi-pad with a multi-generator system, it is important to consider, when designing, the disposition of pads and the piping circuitry in order to ensure adequate safety. Even if one generator fails to operate then the remaining pads must secure the work. Flat with rib For general use and also to be used when work is liable to be deformed Deep type To be used when work surface is curved Piping resistance The piping system should be compatible with the capacity and suction force of the generator. Excessively large piping and oversize pads lead to a long response time. The important point when piping is to make piping volume small, to minimise flow resistance from fittings, tube and pad fittings, and to reduce leakage to a minimum. The information provided in RS technical literature is believed to be accurate and reliable; however, RS Components assumes no responsibility for inaccuracies or omissions, or for the use of this information, and all use of such information shall be entirely at the user s own risk. No responsibility is assumed by RS Components for any infringements of patents or other rights of third parties which may result from its use. Specifications shown in RS Components technical literature are subject to change without notice. RS Components, P Box 99, Corby, Northants, NN17 9RS Telephone: 01536 201234 An Electrocomponents Company RS Components 1997