Large Animal Volume Controlled Ventilator User's Manual

Similar documents
Large Animal Volume Controlled Ventilator User's Manual

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Large Animal Volume Controlled Ventilator

Model 687 Mouse Ventilator User s Manual. Model 687 Mouse Ventilator

Research Grade Blood Pressure Transducer User's Manual

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

IMPORTANT SAFETY INSTRUCTIONS

Model 405 &407 Small Animal Ventilator. User Manual v3.5

100C Air Compressor Kit

444C DUAL PERFORMANCE VALUE PACK

200 PSI COMPRESSORS - MODEL NUMBERS

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Yoke Block Instruction Manual

Index Table. Model 794. Installation, Operating and Maintenance Instructions

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Freedom8 ShoeBox Compressor Manual

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

400C & 450C DUAL PERFORMANCE VALUE PACKS

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Yoke Block Instruction Manual

200 PSI FAST-FILL AIR SOURCE KIT

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

200 PSI HIGH-FLOW AIR SOURCE KIT

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

AIR INLINE METAL SHEAR

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

Operating Manual. Model BAC-30RT30/BAC-30DC

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

5 Channel Calibrator

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

User Instruction Manual

Introduction INDEX. INTRODUCTION HSE

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

Code AWC20HP Air Compressor

PVQ 13 A2 R SE 1 S 20 C-11 D

Operating Instructions Model and Hydrostatic Test Pump

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Model No Product Name Handpiece Only Complete System

Models: C62/63/64-A/D

User s Guide. Vacuum Controller for liquid delivery systems

IMPORTANT SAFETY INSTRUCTIONS

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Techcon Systems TS1254 Pressure Pot

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

EXH. Specifications. Descriptions. Min. working pressure MPa

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

480C DUAL PERFORMANCE VALUE PACK

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

Air Operated Hydraulic Pumping Systems to 50,000 psi

PC1131 Electric Air Compressor

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

Model ASSEMBLY and OPERATING INSTRUCTIONS

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

SPECIFICATIONS ATTENTION

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

REPAIR PART NUMBER NUMBER DESCRIPTION 0137 ELE 0136 ELE 12 VOLT SOLENOID

J Air and Water Kit Instructions Part# 02584

D Series Air and Water Kit Part# 02550

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

Budget Range Operators Handbook

In Vivo Scientific, LLC INSTRUCTION MANUAL

CS150 CAP STAPLER OWNER S MANUAL

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

Instruction Manual Updated 7/26/2011 Ver. 2.2

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

MODEL NUMBER: AS18-2 USER GUIDE

MD R a n g e O p e r a t o r s H a n d b o o k

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

VAPOMATIC ANESTHETIC VAPORIZER

2 Gallon, 100 PSI Oilless

RoVent Jr. Automatic Ventilator Volume & Pressure Controlled. User s Guide

IMPACT WRENCH ASSEMBLY AND OPERATING INSTRUCTIONS

INFUSION SYSTEM (110V) (220V) USER S MANUAL

COMPRESSOR MANUAL. (888)

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

MODEL NUMBER: P PORTABLE COMPRESSOR

Columbus Instruments

Operating Instructions Models and Hydrostatic Test Pumps

M5400 Operators Manual

Marschalk Model # 94000

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

The Univentor 1250 Anaesthesia Unit

Transcription:

Large Animal Volume Controlled Ventilator User's Manual Large Animal Volume Controlled Ventilator, 115 VAC/60 Hz55-0715 Large Animal Volume Controlled Ventilator, 230 VAC/50 Hz55-0723

1 Table of Contents SUBJECT PAGE Warranty and Repair Information...2 General Information...3 Description...3 Specifications...3 Operation...4-6 Volume Adjustment...4-5 Recommended Setup...6 Dual Rate Compensation Chart...7 Ventilation Graph...8 Maintenance Instructions...9 Model 613 Parts and Assembly Drawing...10 Parts List...11 Repair Kit Information...12

2 Warranty and Repair Information Serial Numbers All inquires concerning our product should refer to the serial number of the unit(s). Warranty Harvard Apparatus warranties the instrument(s) for a period of one year from date of purchase. At its option, Harvard Apparatus will repair or replace the unit(s) if it is found to be defective as to workmanship or material. This warranty does not extend to damage resulting from misuse, neglect or abuse, normal wear and tear, or accident. This warranty extends only to the original customer purchaser. IN NO EVENT SHALL HARVARD APPARATUS BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you. THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR USE, OR OF ANY OTHER NATURE. Some states do not allow this limitation on an implied warranty, so the above limitation may not apply to you. If a defect arises within the one-year warranty period, promptly contact Harvard Apparatus, Inc. 84 October Hill Road, Holliston, Massachusetts 01746-1371 using our U.S. only toll free number 1-800-272-2775 or dial (508) 893-8999. Goods will not be accepted for return unless an RMA (returned materials authorization) number has been issued by our customer service department.the customer is responsible for shipping charges. Please allow a reasonable period of time for completion of repairs, replacement and return. If the unit is replaced, the replacement unit is covered only for the remainder of the original warranty period dating from the purchase of the original device. This warranty gives you specific rights, and you may also have other rights which vary from state to state. Repair Facilities and Parts Harvard Apparatus stocks replacement and repair parts. When ordering, please describe parts as completely as possible, preferably using our part numbers. If practical, enclose a sample or drawing.we offer a complete reconditioning service. CAUTION: Not for clinical use on human patients.

3 General Information Description The Large Animal Volume Controlled Ventilator, Model 613, is designed for use with dogs and other large animals over 1 kilogram body weight. It has variable controls for inspiration rate (speed control) and inspiratory ratios ranging from 25-50%.The vertical slide valve provides separate pathways for inspired and expired air. Volume adjustment is made on the piston shaft, and therefore accurate volume adjustment cannot be made while the ventilator is running. However, the rate and the I:E % can be varied while the ventilator is running. Air/gas valving is by the four port system with separate ports for gas inlet, gas outlet (to animal), gas return (from animal), and ventilator exhaust. The gas inlet can be used to supply air or any non-flammable gas supply.like the other Harvard mechanical ventilators, attachment of the ventilator exhaust to a column of water can be used to produce a positive and expiratory pressure (PEEP). Specifications Volume Rate Phase Port Size: ID OD Dimensions, HxWxD Weight Power Requirements Adjustable from 30 to 750 cc/stroke. Note: Volume adjustment is made on crank, and therefore accurate volume adjustments cannot be made while ventilator is running Adjustable from 7 to 50 strokes/min while ventilator is running Adjustable from 25 to 50% of single stroke cycle continuously variable while pump is in operation 12.7 mm (1/2 in) 15.9 mm (5/8 in) 30 x 50 x 22.5 cm (12 x 20 x 9 in) 21 kg (45 lb) 110-120 V / 50-60 Hz unless otherwise specified; 110 watt max Inspire/Expire Ratio 25/75 to 50/50 Motor Dual phase, 1/15 h.p. gear head motor Variable Speed Control Motor speed is electronically controlled by solid state SCR system. AC line voltage is rectified to provide fixed DC voltage to motor field and variable DC voltage to armature Variable Phase Control Solid-state, dual phase electronic motor control is coupled to DC shunt wound motor. Cam-actuated micro-switch operates electronic phase control. Fuse Motor control is protected by 2 Amp Slo-Blo fuse. DO NOT REPLACE with higher-rated fuse. Plug 3-prong molded connector

4 Operation 40 35 CAUTION: This pump is not to be used in an explosive atmosphere or with any explosive gases such as ether, cyclopropane, etc. HARVARD APPARATUS DUAL PHASE CONTROL RESPIRATOR PUMP % INSPIRATION BREATHS / MIN 50 45 55 30 70 60 65 20 25 30 35 40 10 45 5 2.50 50 ON 2.0A S.B. OFF Figure 1. Control Panel for Large Animal Volume Controlled Ventilator, Model 613

5 Operation Connecting Rod Adjusting Nut Calibration Panel Figure 2. Stroke Volume Adjustment % Inspiration This knob controls the inspiratory ratio.the inspiratory ratio can be changed from 25-50% of a single stroke cycle.this control is continuously variable while the pump is in operation. Breaths/Min This knob controls the number of strokes/minute to be delivered by the pump.the stroke rate is affected by the phase control setting.please refer to graph on page 7.The Stroke Rate Control is continuously variable while the pump is in operation. Stroke Volume Adjustment Stroke Volume is determined by the position of the Connecting Rod on the crank. Loosen the Adjusting Nut, set the Connecting Rod to the desired position according to the Calibration Panel, and then tighten. (See Ventilation Graph, pg. 8). CAUTION: Stroke volume should not be adjusted while the pump is in operation. CAUTION: Stroke volume should not be adjusted while pump is in operation.

6 Operation Tracheal Cannula or Endotrach Tube "Y" Connector (close to animal) From Animal To Animal Cylinder Figure 3. Setup Configuration Expired Air Plastic Tubing Air/Gas Input Recommended Setup The basic pump is equipped with a length of plastic tubing connecting the output port on the Cylinder to the input port on the Valve.The lower port (Input) on the Valve directs air to the animal while the upper port (Output) conducts air from the animal to the room atmosphere. A Y Connector should be used to couple the upper and lower port tubes to the tracheal cannula.the Y Connector should be placed as close as possible to the animal in order to minimize the common pathway between inspired and expired air.

7 Dual Phase Rate Compensation Chart Phase Ratio (% Inspiration) Typical plot of actual stroke rate at various ratios and strokes. Figure 4. Dual Phase Rate Compensation Chart Note:Actual I/E ration range is 25/75 to 50/50. The graph above, taken from tests on a Harvard Model 613 Ventilator, is typical of the performance expected from a dual phase motor control pump. As observed, actual stroke rate varies considerably as the phase ratio reaches its outer limits. Users should be aware of this relationship and develop appropriate curves to assure experimental data.

8 Ventilation Graph 500 400 300 200 Tidal Volume vs. Weight and Rate for Laboratory Mammals in Resting State (apparatus dead space must be added) Ventilation Graph Tidal Volume vs. Weight and Rate for Laboratory Mammals in Resting State. (Apparatus dead spade must be added) 70 100 200 300 400 600 800 1 2 3 4 5 6 8 10 15 20 30 40 500 400 300 200 Tidal Volume (ml at Ambient Temperature) 150 100 80 60 50 40 30 20 15 10 8 6 5 4 3 2 Breaths per Minute: 10 15 20 25 30 100 60 70 80 90 50 40 150 100 80 60 50 40 30 20 15 10 8 6 5 4 3 2 1 0.8 40 1 0.8 0.6 0.5 0.4 0.4 70 100 200 300 400 600 800 1 2 3 4 5 6 8 10 15 20 30 40 0.6 0.5 (Grams) Tidal Volume (Kilograms) Figure 5.Ventilation Graph

9 Maintenance Instructions Lubrication Requirements Pump: The slide valve and the inside of the cylinder should be lubricated every six months with Dow Corning #33 Compound silicone grease (1 ounce jar is provided). This grease is also available as part of the Model 616 Repair Kit for Model 613 Ventilators. The connecting rod has an oil hole at each end for application of light machine oil. Machine oil is also available as part of the 616 kit. Motor: Motor bearings and ball bearings--all bearings are grease lubricated.additional lubrication is required if the pump has been run for 5 years or 10,000 operating hours, whichever comes first.these figures should serve as a guide providing that the pump is run at normal ambients and is not overly abused. For more severe conditions, more frequent servicing is required.andok C. (Penola, Inc.) or BRB #4 (Socony Oil) should be used for lubrication. Gear Reducers: Reducer housings have no sight gauge or level plug. The housings are filled to 3/4 capacity with Hodson #2-1000 No-Melt Grease.This will be sufficient for a 5 year period.to relubricate types N-10R6 reducers, remove the gear housing, clean out the old grease, and refill to 3/4 capacity with Hodson Lubricant mentioned above.to relubricate types N-1RH, N-3R, N-3RH, and N-5R reducers, remove the gear housing end shields supporting the drive shaft, clean out the old lubricant and refill to 3/4 capacity with the same Hodson grease. Note: Some gear reducers also have oilers on the output shaft binding hubs. For normal duty, lubricate every 3 months with.02 fluid ounces of the oil supplied, or any equivalent oil (such as 3 in 1 oil). Cylinder Valves: Disassemble every six months for inspection and removal of foreign matter. Water Removal: Water removal plug is provided at the bottom of the cylinder. Periodically release the valve to drain off any excess moisture that has accumulated.

10 Model 613 Ventilator Schematic 0606-010 0606-079 0606-031 5009-087* 0606-039 5013-002* 0606-044 0613-023 5153-003 0606-091 0606-040 0606-083* 0606-041 5013-038* 0614-030 0606-114 5103-021 0606-082* 5110-003 5100-013 0606-030 5112-105 5013-017 5013-023* *Supplied in Repair Kit #616 Figure 6. Large Animal Volume Controlled Ventilator Model 613 Parts and Assembly Drawing

11 Model 613 Ventilator Parts List Model No. Description Quantity Per Unit 0606-010 Cap (Chrome) 1 0606-030 Cam Follower 1 0606-031 Plunger 1 0606-039 Block-Crank Sliding 1 0606-041 Washer-Flat Precision 1 0606-044 Cam 1 0606-079 Tubing, Plastic, 24 long 1 0606-082 Assembly Intake Valve 1 0606-083 Assembly Exhaust Valve 1 0606-091 Pin Crank 1 0606-114 Volume Adjusting Knob 1 0613-023 Crank 1 0614-030 Male Valve Cover 2 5009-087 Spring 1 5013-002 O Ring, Parker #2-111 3 5013-017 O Ring, Parker #2-8 1 5013-023 O Ring, Parker #2-336 2 5013-038 O Ring, Parker #2-21 4 5100-013 Thumb Screw #10-32 1 5103-021 Acorn Nut #1/4-28 1 5110-003 Curved Spring Washer 1 5112-105 Micro Switch Only 1 5153-003 Motor Speed Control 1

12 Repair Kit Information Model 616 Repair Kit for #607 and #613 Ventilators The 613 Ventilator is built for many years of reliable operation. However, it does require reasonable care and maintenance to keep it in good condition.we strongly recommend that the pump undergo yearly parts replacement and lubrication.the Model 616 Repair Kit for the 613 Ventilator contains a complete collection of rings, valves, springs, gaskets, and lubricants. Also included is a set of instructions for overhauling procedures.the kit contains the following items: Model No. Description Quantity Per Unit 0606-028 Gaskets, Intake and Exhaust Valves 4 0606-030 Nylon Plunger Tip 1 0606-060 Oil, 3/4 oz. Bottle 1 0606-082 Intake Valve Assembly 1 0606-083 Exhaust Valve Assembly 1 0606-084 Silicone Grease 1 5009-152 Spring for Slide Valve 1 5013-002 O Rings for Slide Valve Rod (5/8 ) 3 5013-023 O Rings for Piston (3-1/4 OD) 2 5013-038 O Rings, Intake and Exhaust Valves 4