Differential Pressure Control Types MP 54, MP 55 and MP 55A

Similar documents
Differential pressure switch MP 54, MP 55 and MP 55A

Differential pressure controls, Type MP 54, 55 and 55A

Differential pressure switch / Lube oil protection control MP 54 and MP 55

Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING. Technical leafl et

Pressure controls for hydro carbons, zone II applications, Type KPE

Pressure switch KP-E. Data sheet

Pressure switch and Thermostat CAS

Pressure controls, differential pressure controls type RT

Pressure switch and Thermostat KPS

Pressure switch and Thermostat Type KPS

Pressure switches for air and water CS

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Data sheet. Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E B0782

Pressure switch, Differential pressure switch and Thermostat RT-E

Pressure switches and thermostats, type KPS

Condensing pressure regulator, type KVR Differential pressure valve, type NRD

Pressure control, differental pressure control and thermostat Type RT

Evaporator pressure regulator Type KVP

Condensing pressure regulator, type KVR Receiver pressure regulator, type NRD

Pressure transmitters EMP 2

Pressure switch Type BCP

Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet

TeSys protection components

Pressure switch RT. Data sheet

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

Position switches FP series

Evaporator pressure regulator Type KVP

Electromechanical pressure switches

Solenoid valve type EVR for Hydrocarbons

Types and approvals. Page 1/6. Data Sheet

Pilot valves for pilot operated servo valves

Prewired position switches FA series

MAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.

Float valves Types SV 1 and SV 3

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Technical leaflet. Pressure and Temperature Regulators. January 1999 RC.4X.B1.22. Danfoss A/S

2-step solenoid valve Type ICLX

SITRANS P measuring instruments for pressure

Electromechanical pressure switches

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Meta-MEC Manual Motor Starters

Float valves Types SV 4, SV 5 and SV 6

Gas density monitor With integrated transmitter Model GDM-100-TI

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Pressure switch SANHUA PS01/50/15 SERIES. ideas worldwide STANDARD

Electric expansion valves Types AKV 10, AKV 15 and AKV 20

2-step solenoid valve Type ICLX

) for different types of systems Test of contact function The correct pressure control for your system

Liquid level regulating valves Types PMFL / PMFH and SV

CALEFFI. Ball zone valves. series /03 GB

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Operating Instructions

ATH-EXx. B Operating Instructions

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

Dual position solenoid valve Type ICSH 25-80

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Tightness controls TC 1 3 and TC 4

ATH-EXx. B Operating Instructions

Shut-off ball valve Type GBC

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

High-performance submersible pressure transmitter For level measurement Model LH-10

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

EX-RECESSED CEILING LIGHT FITTINGS

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

2-port seat valves PN25 with externally threaded connections

JUMO dtrans p30 Pressure Transmitter

Prewired position switches FA series

High-performance submersible pressure transmitter For level measurement Model LH-10

Monitoring device NTS 30

Compact pressure switches for gas and air

XML Electromechanical Pressure Switches

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

Manual Power relay SR853

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

XMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

Solenoid Valves, one - or two step, on/off ICLX

Operating Instructions

Pressure Switch for gas and air GGAO-A4

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

Technical Data. Dimensions

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

[Instruments for vacuum measurement, checking and adjustment] 3

Modulating liquid level regulators, direct-controlled, type SV 1 and 3 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Pressure Switch for gas and air

Pressure regulating valves Types OFV, OFV-SS

Sales Office: Danfoss Expansion Valves. T*2 Range Order valve and orifice separately Range N -40 C to +10 C Without MOP

Shut-off ball valve Type GBC

Valve Proving System VDK 200 A S02

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10.

Valve Proving System VDK 200 A S06*

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

SPECIFICATIONS ATTENTION

Emergency Stop Devices/Rope Pull Switches

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Operating Instructions Rope Pull Switches RPS...

Transcription:

MAKING MODERN LIVING POSSIBLE Data sheet Differential Pressure Control Types MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure controls are used as safety switches to protect refrigeration compressors against low lubricating oil pressure. If the oil pressure fails the oil differential pressure control stops the compressor after a certain time period. MP 54 and MP 55 are used in refrigerating systems using HCFC and non-flammable HFC refrigerants. MP 55A is used in refrigerating systems with R717. MP 55A can also be used in systems with HCFC and non-flammable HFC refrigerants. MP 54 has a fixed differential pressure setting. It also incorporates a thermal time relay with a fixed release time setting. MP 55 and MP 55A have adjustable differential pressure and are available both with and without thermal time relay. Features y Wide regulating range y Can be used for deep freeze, refrigeration and air conditioning plant y Can be used for HCFC and non-flammable HFC refrigerants y Electrical connection at the front of the unit y Suitable for both alternating and direct current (a.c. and d.c.) y Screwed cable entry for cables from 6 14 mm diameter y Small contact differential Approvals CE mark according to LVD 2006/95/EC EN 60947-1, EN 60947-4-1, EN 60947-5-1 China Compulsory Certificate, CCC Versions having UL and CSA approvals can be supplied to special order Ship approvals Germanischer Lloyd, GL Registro Italiano Navale, RINA (MP55) DKRCC.PD.CG0.B7.02 / 520H7400

Materials in contact with the medium Unit type MP 54 MP 55 MP 55A Material Stainless steel 19/11, no. 1.4306 to EN 10088 Cold forming steel, no. 1.0338, EN 10139 Free cutting steel, no. 1.0718, EN 10277 Stainless steel 19/11, no. 1.4306 to EN 10088 Cold forming steel, no. 1.0338, EN 10139 Free cutting steel, no. 1.0401, EN 10277-2 Technical data Control voltage Permissible voltage variation -15 10% Max. working pressure Max. test pressure Ambient temperature The time relay is temperature-compensated in the range 230 V or 115 V a.c. or d.c. PS/MWP = 17 bar Pe = 22 bar -40 60 C Screwed cable entry Pg 13.5 Cable diameter 6 14 mm Max. bellows temperature 100 C Switch differential max. p [bar] 0.2 Enclosure IP20 to EN 60529 / IEC 60529 Contact loads MP with time relay (contacts M-S) MP without time relay AC15 = 2 A, 250 V DC13 = 0.2 A, 250 V AC15 = 0.1 A, 250 V DC13 = 12 W, 125 V solid / stranded 0.2 1.5 mm 2 Wire dimensions flexible, without ferrules 0.2 1.5 mm 2 flexible, with ferrules 0.2 1 mm 2 Tightening torque Rated impulse voltage max. 1.2 Nm 4 kv Pollution degree 3 Short circuit protection, fuse Insulation 2 A 250 V Terminology Differential range The pressure difference between LP and OIL connections within which the control can be set to operate. Scale reading The differential between the oil pump pressure and the pressure in the crankcase that exists at the moment the contact system cuts in current to the time relay on falling oil pressure. Operating range The pressure range on the LP connection within which the control can operate. Contact differential The pressure rise above the set differential pressure (scale reading) necessary to cut off current to the time relay. Release time The period for which the differential pressure control allows the compressor to run with too low an oil pressure during start-up and operation. 2 DKRCC.PD.CG0.B7.02 / 520H7400

Ordering For HCFC and non-flammable HFC refrigerants Type Differential p Operation range, LP side Relay release time [bar] [bar] [s] 1 / 4 in. Flare Code no. Connection 1 m cap.tube 1 / 4 in. ODF solder M12 x 1.5 with 6 mm cutting ring 0.65-1 12 0 2) 060B029766 0.65-1 12 45 060B016666 MP 54 0.9-1 12 60 060B016766 0.65-1 12 90 060B016866 0.65-1 12 120 060B016966 0.3 4.5-1 12 45 060B017066 060B013366 0.3 4.5-1 12 60 060B017166 MP 55 0.3 4.5-1 12 60 060B017866 1) 0.3 4.5-1 12 90 060B017266 0.3 4.5-1 12 120 060B017366 0.3 4.5-1 12 0 2) 060B029966 For R717, HCFC and non-flammable HFC refrigerants Type Differential p Operation range, LP side Relay release time [bar] [bar] [s] Code no. Connection G 3 / 8 A supplied with ø6.5 / ø10 mm weld nipple M12 1.5 with 6 mm cutting ring 0.3 4.5-1 12 45 060B017466 060B018266 0.3 4.5-1 12 60 060B017566 060B018366 MP 55A 0.3 4.5-1 12 60 060B017966 1) 0.3 4.5-1 12 90 060B017666 060B018466 0.3 4.5-1 12 120 060B017766 060B018566 0.3 4.5-1 12 0 2) 060B029866 2) 060B029666 1) With glow lamp that remains on during normal operation. Note: If the operational light goes out, the compressor should not run longer than the release time. 2) MP without time relay. Versions without time relay are for applications where an external time relay is required perhaps with a different release time than the one specified. Design 2 4 The operation of the pressure control relies only on the differential pressure, i.e. the difference in pressure between the two counteracting bellows, whereas it is independent of the absolute pressure acting on both bellows. The MP 55 and 55A can be set for different differential pressures by the setting disc (3). 3 The set differential pressure can be read from the internal scale. The MP 54 has a fixed differential and has no pressure setting disc. 1. Connection to pressure side of lubrication system, OIL 2. Connection to suction s ide of refrigeration plant, LP 3. Setting disk (MP 55 and MP 55A) 4. Reset button 5. Test device 5 MP 55 1 The factory-set differential pressure is stamped on the front plate of the control. DKRCC.PD.CG0.B7.02 / 520H7400 3

Function If there is no oil pressure on starting, or if the oil pressure falls below the set pressure during operation, the compressor will stop after the release time has elapsed. The electrical circuit is divided into two completely separate circuits, a safety circuit and an operational circuit. The timer (e) in the safety circuit is activated when the effective lubricating oil pressure, the oil differential pressure (the difference between the oil pump pressure and suction pressure), is lower than the set value. The timer is deactivated when the oil differential pressure is more than the set value plus the contact differential. Electrical diagram TEST RESET OIL The two diagrams below explain the terms "oil differential pressure" and "contact differential". Both have to be considered when using oil differential pressure controls. The first diagram shows the function of the differential control during start; the second shows the function of the control during operation. [bar] Switch differential Control differential On start-up [s] 4 DKRCC.PD.CG0.B7.02 / 520H7400

Function (continued) Pos. A: Normal start-up The lubricating oil pressure is built up during start to the set/fixed differential plus the contact differential, before the timer cuts out (in this example, after 45 seconds). At point A contacts T1-T2 open and timer (e) is stopped, i.e. normal lubricating oil conditions for the compressor have been established. Pos. B: The lubricating oil pressure does not reach the set/fixed differential plus the contact differential before the timer period elapses. At point B the timer cuts out operational circuit L-M and the compressor stops. If a signal source is connected to terminal S, it will be activated. Restart can only be performed after about 2 minutes by activation of the reset button, provided the cause of the fault has been determined. [bar] [s] During operation Pos. C: The lubricating oil pressure falls during operation to a value lower than the set/fixed differential. At point C, safety circuit T1-T2 cuts in and the timer is activated. Pos. D: The lubricating oil pressure reaches the set/fixed differential plus the contact differential before the timer period elapses. At point D, safety circuit T1-T2 cuts out and the timer is stopped, i.e. normal lubricating oil conditions for the compressor have been established. Pos. E: The lubricating oil pressure falls to a value lower than the set/fixed differential during operation. At point E, safety circuit T1-T2 cuts in and the timer is activated. Pos. F: The lubricating oil pressure remains lower than the set/fixed differential. At point F the timer cuts out operational circuit L-M and the compressor stops. If a signal source is connected to terminal S, it will be activated. Restart can only be performed after about 2 minutes by activation of the reset button, provided the cause of the fault has been determined. After start-up It is important that a function check should be made to ensure that the differential pressure control is operating as it should. This check can be made by pressing the test device (inside the unit on the left hand side). When the test device is pressed down and held in this position the compressor motor should stop after the release time determined by the time relay has elapsed. DKRCC.PD.CG0.B7.02 / 520H7400 5

Dimensions [mm] and weight [kg] MP 54, MP 55, MP 55A Net weight approx. 0.8 kg 6 DKRCC.PD.CG0.B7.02 / 520H7400 Danfoss A/S (AC-MCI /jmn), 2013-02