Electromechanical pressure switches
|
|
- Grace Young
- 5 years ago
- Views:
Transcription
1 References : pages / and / page /5 Presentation Functions Pressure switches type XMX and XMA are switches for control circuits, with an adjustable differential. They are used to control the pressure of water and air, up to 5. Equipment fitted to various models Location of setting screw Pressure switches type XMX have an internal setting screw, only accessible after removing the cover. Pressure switches type XMA have an external setting screw, accessible without removing the cover. Case Pressure switches type XMX have a black opaque case. Pressure switches type XMA can have a transparent case or a black opaque case. Setting When setting XMX or XMA pressure switches, adjust the switching point on rising pressure (PH) first and then the switching point on falling pressure (PB). Switching point on rising pressure The switching point on rising pressure (PH) is set by adjusting screw-nut. Switching point on falling pressure The switching point on falling pressure (PB) is set by adjusting screw-nut. / Te
2 References : pages / and / page /5 Characteristics Environment Conforming to standards è, IEC/EN Product certifications Protective treatment UL, CSA (pending) TC Ambient air temperature C Operation : Storage : Fluids controlled Materials Air, fresh water, sea water ( + 7 C) Case : polycarbonate impregnated with Lexan 5R fibre glass (black opaque cover) or polycarbonate impregnated with Lexan fibre glass (transparent cover). Component materials in contact with fluid : chromated zinc alloy (fluid enrty), nitrile covered canvas (diaphragm) Operating position All positions Electric shock protection Class I conforming to IEC 5 Degree of protection IP 5 conforming to IEC/EN 59 Operating rate Operating cycl/min. Repeat accuracy <.5 % Fluid connections /" or x /" BSP (female) conforming to NF E -5, ISO 8 Electrical connections Contact block characteristics Screw terminals. tapped entries for Pg.5 cable gland Rated operational characteristics c AC-5, B (Ue = V, Ie =.5 A ; Ue = V, Ie = A) a DC-, R (Ue = 5 V, Ie =. A) Rated insulation voltage V Ui = 5, conforming to IEC/EN 97- Rated impulse withstand voltage kv U imp = conforming to IEC/EN 97- Contact operation C/O single-pole contact, snap action Terminal referencing Conforming to CENELEC EN 5 Short-circuit protection A cartridge fuse type gg (gi) Cabling Screw clamp terminals. Clamping capacity, min. : x mm, max. : x.5 mm Electrical durability a.c. supply 5/ Hz, Ith = A Inductive circuit, utilisation category AC-5, A/ V : million operating cycles Te /
3 Accessories : page / page /5 For control circuits, type XMX Sizes to 5 (87 to.5 psi). Adjustable differential, for regulation between thresholds. Switches with C/O single-pole contact References, characteristics Pressure switches type XMX (internal setting screw) Adjustable range of switching point (PH) () (.5 87 psi) ( psi) ( psi) (.5 87 psi) ( psi) ( psi) Fluid connection /" BSP (female) x /" BSP (female) References Switches with black opaque cover Fluids controlled : air, fresh water, sea water, from C to + 7 C () XMX-AL5 XMX-AL5 XMX-A5L5 XMX-AL5 XMX-AL5 XMX-A5L5 Weight (kg) Complementary characteristics not shown under general characteristics (page /) Possible Min. at low setting.8 (. psi) (.5 psi). (9. psi).8 (. psi) (.5 psi). (9. psi) differential (subtract from Min. at high setting. (7. psi).7 (. psi).5 (5. psi). (7. psi).7 (. psi).5 (5. psi) PH to give PB) Max. at high setting. (.9 psi) 8. (.8 psi) (9 psi). (.9 psi) 8. (.8 psi) (9 psi) Maximum Per cycle 7.5 (8.7 psi) 5 (7.5 psi).5 (5. psi) 7.5 (8.7 psi) 5 ( 7.5 psi).5 (5. psi) permissible pressure Occasional surge.5 (95.7 psi) 7 (9.5 psi) 5.5 (85. psi).5 (95.7 psi) 7 (9.5 psi) 5.5 (85. psi) Destruction pressure (5 psi) (5 psi) (5 psi) (5 psi) (5 psi) (5 psi) Mechanical durability Cable entry x operating cycles entries tapped for Pg.5 cable gland Pressure switch type Operating curves XMX-Aiiiii 5 Diaphragm XMX-Aiiiii 8 XMX-A5iiiii 5 5 Pressure PH PB,,8,8 Maximum differential Minimum differential,,, 8, Maximum differential Minimum differential () See Component materials of switch in contact with the fluid, page /.,5, 5 5,5 5 Maximum differential Minimum differential Time Adjustable value Connections Other versions / Te Pressure switches with alternative tapped cable entries : ISO, NPT, etc. Please call our Customer information centre on
4 Accessories : page / page /5 For control circuits, type XMA Sizes to 5 (87 to.5 psi). Adjustable differential, for regulation between thresholds. Switches with C/O single-pole contact References, characteristics Pressure switches type XMA (external setting screw) Adjustable range of switching point (PH) () (.5 87 psi) ( psi) ( psi) (.5 87 psi) ( psi) ( psi) Fluid connection /" BSP (female) x /" BSP (female) References Switches with black opaque cover Fluids controlled : air, fresh water, sea water, from C to + 7 C XMA-HL5 XMA-HL5 XMA-H5L5 XMA-HL5 XMA-HL5 XMA-H5L5 Switches with transparent cover Fluids controlled : air, fresh water, sea water, from C to + 7 C XMA-VL5 XMA-VL5 XMA-V5L5 XMA-VL5 XMA-VL5 XMA-V5L5 Weight (kg) Complementary characteristics not shown under general characteristics (page /) Possible Min. at low setting.8 (. psi) (.5 psi). (9. psi).8 (. psi) (.5 psi). (9. psi) differential (subtract from Min. at high setting. (7. psi).7 (. psi).5 (5. psi). (7. psi).7 (. psi).5 (5. psi) PH to give PB) Max. at high setting. (.9 psi) 8. (.8 psi) (9 psi). (.9 psi) 8. (.8 psi) (9 psi) Maximum Per cycle 7.5 (8.7 psi) 5 (7.5 psi).5 (5. psi) 7.5 (8.7 psi) 5 ( 7.5 psi).5 (5. psi) permissible pressure Occasional surge.5 (95.7 psi) 7 (9.5 psi) 5.5 (85. psi).5 (95.7 psi) 7 (9.5 psi) 5.5 (85. psi) Destruction pressure (5 psi) (5 psi) (5 psi) (5 psi) (5 psi) (5 psi) Mechanical durability x operating cycles Cable entry entries tapped for Pg.5 cable gland Pressure switch type Diaphragm Operating curves XMA-iiiiii iiiii XMA-iiiiii iiiii XMA-i5iiiii iiiii Pressure PH PB 5,,8,8 Maximum differential Minimum differential,, 8, Maximum differential Minimum differential () See Component materials of switch in contact with the fluid, page /.,,5, 5 5,5 5 Maximum differential Minimum differential Connections Time Adjustable value Other versions Pressure switches with alternative tapped cable entries : ISO, NPT, etc. Please call our Customer information centre on Te /
5 Accessories and replacement parts page /5 References Description Reference Weight kg Fixing bracket XMA-ZL.5 XMA-ZL XML-ZL Knurled adjustment knob, Ø mm XML-ZL. fits over adjustment screws to facilitate setting Pg.5 plastic With anti pull-out ring DE9-PM.5 cable gland (for cable Ø 9 mm) DE9-PM Without anti pull-out ring DE9-PM.5 (for cable Ø 9 mm) With anti pull-out ring DE9-PM.5 (for cable Ø 9.5 mm) DE9-PM Without anti pull-out ring DE9-PM.5 (for cable Ø 9.5 mm) Description For pressure switch Reference Weight kg Diaphragms Size XMP-Z.5 XMP-Zi Size XMP-Z.5 Size 5 XMP-Z.5 / Te
6 Characteristics : page / References : pages / and / Dimensions XMX-AL5, XMX-AL5 XMA-iL5, XMA-iL5 XMA : 7 XMX-AL5, XMX-AL5 XMA-iL5, XMA-iL5 XMA : 7 (), ,5 r = () A ØA = /" BSP (female) ØA = ØB = ØC = ØD = /" BSP (female) () tapped entries for Pg.5 cable gland () tapped entries for Pg.5 cable gland () Minimum clearance zone for screwing-on pressure switch at point A () Minimum clearance zone for screwing-on pressure switch at point A XMX-A5L5, XMX-A5L5 Fixing bracket XMA-i5L5, XMA-i5L5 XMA-ZL Ø5, Ø,,, ØA,5 = = 57 ØC ØA (), ,5,5 = = 57 r = () D C A B XMA : 7 8,5,5 8 5 ØC () ØA, ,5 D,5 = = 57 r = () C A B XMi-i5L5 : ØA only = /" BSP (female) XMi-i5L5 : ØA = ØB = ØC = ØD = /" BSP (female) () tapped entries for Pg.5 cable gland () Minimum clearance zone for screwing-on pressure switch at point A Te /5
Electromechanical pressure switches
Presentation Electromechanical pressure switches OsiSense XM For power circuits, type XMP Presentation Pressure switches type XMP are switches for power circuits (direct switching), with an adjustable
More informationXMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type
Characteristics pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type Main Range of product Pressure sensor type Pressure sensor name Pressure sensor size OsiSense XM Electromechanical
More informationReferences, characteristics. References (1) Complementary characteristics not shown under general characteristics (page 30395/3)
References, characteristics Electromechanical pressure switches For power circuits, type XMP. IP degree of protection Size (87 psi). Adjustable differential, for regulation between thresholds Switches
More informationXML Electromechanical Pressure Switches
Selection Guide Industrial Switches Type of installation ontrol circuits Applications Media controlled Type of operation Air, water, hydraulic oils, corrosive fluids, viscous products Fixed differential:
More informationLimit switches OsiSense XC Special For material handling applications, type XC1 AC
Presentation For material handling applications, type XC C b XC C with slow break contacts v With head for linear movement () 00_ 00_ 000_ Page / 00_ 00_ XCC XCC Page / XCC XCC / General characteristics
More informationPrewired position switches FA series
2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45
More informationPosition switches FP series
A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever
More informationPrewired position switches FA series
Prewired position switches Technical data Housing Made of metal, coated with baked epoxy powder 2 m wired cable with 5x0,5 mm 2 wires marked SEV and IMQ Protection degree: IP6 General data Ambient temperature:
More informationData sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119
Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,
More informationEmergency Stop Devices/Rope Pull Switches
Rope pull switch with pulltoreset button for emergency stop device Metal housing Emergency stop device with detent mechanism according to EN ISO 13850 and EN 602041 Clamping head for pull rope Indication
More informationZelio Relays RSL Slim Interface Plug-In Relays
Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3
More informationPressure switches for air and water CS
Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the
More informationDifferential Pressure Control Types MP 54, MP 55 and MP 55A
MAKING MODERN LIVING POSSIBLE Data sheet Differential Pressure Control Types MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure controls are used as safety switches to protect refrigeration
More informationTeSys protection components
Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively
More informationDifferential pressure controls, Type MP 54, 55 and 55A
MAKING MODERN LIVING POSSIBLE Technical brochure Differential pressure controls, Type MP 54, 55 and 55A MP 54 and oil pressure controls are used as safety switches to protect refrigeration compressors
More informationDifferential pressure switch MP 54, MP 55 and MP 55A
Data sheet Differential pressure switch MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors against low lubricating
More informationPressure switch and Thermostat Type KPS
MAKING MODERN LIVING POSSIBLE Data sheet Pressure switch and Thermostat Type KPS The KPS Series consists of a series of pressure and temperature controlled switches. In this series, special attention has
More informationOperating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073
Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4
More informationPressure switch and Thermostat KPS
Data sheet Pressure switch and Thermostat KPS The KPS Series consists of a series of pressure and temperature controlled switches. In this series, special attention has been given to meeting demands for
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationPressure Switch for gas and air GGAO-A4
Pressure Switch for gas and air GGAO-A4 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 Commonwealth of Massachusetts Approved Product Approval code G3-0106-191 Gas pressure switch Codes
More informationPressure switches and thermostats, type KPS
Description KPS units are pressure-controlled switches. The position of the contacts depends on the pressure in the inlet connection and the set scale value. In this series, special attention has been
More informationPressure switch and Thermostat CAS
Data sheet Pressure switch and Thermostat CAS The CAS Series consists of a series of pressure controlled switches and temperature controlled switches. In this series, special attention has been given to
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More information1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure
Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3
More informationCMC Series Moulded Case Circuit Breaker Cielo Electric
Model name CMC: Series 225: mpere frame size Line side terminal In: Rated current Ue: Rated operational voltage Icu: Rated ultimate short-circuit breaking capacity Ta: mbient temperature In: 225 Icu: 55k@415V
More informationData sheet. Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E B0782
Data sheet Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E2.02 520B0782 Survey Type KPS pressure switches 1. Standard pressure switches Range Further -1 0 10 20 30 40 50 60 bar P e Type
More informationMeasurement of Low GAS & Liquid Flows
Measurement of Low GAS & Liquid Flows The Measurement Measurement with a float in a tapered borosilicate glass tube. Series 2100 with a 100 mm flow tube Series 2150 with a 150 mm flow tube Series 2300
More informationJUMO dtrans p30 Pressure Transmitter
609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationModel range*1) Switching pressure difference
Pneumatic pressure switch electromechanical actuated -...00 bar, G/2 Microswitch with gold plated contacts Intrinsically safe operation Electrical connection: connector acc. to IN EN 7530-803 (form A)
More informationTypes and approvals. Page 1/6. Data Sheet
Page 1/6 Panel-mounting Thermostats EM Series as: Protection temperature monitor STW (STB) Protection temperature limiter STB tested to DIN 3440 and Pressure Equipment Directive 97/23/EC Brief description
More informationPressure switch KP-E. Data sheet
Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches
More informationLevel switches Series LD Vibrating fork level switch for liquids and solids
Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant
More informationCompact differential pressure switch Flameproof enclosure Ex d Models DE, DEC
Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring
More informationPressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. 13 and No. 0 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
More informationAvailable models Devices Color White sealing bellows Black sealing bellows NDT SW NDT GB NDT RT NDT GN NDT WS NDT BL NDT GR
Pushbuttons Left: type series N with sealing bellows, color white (standard). Right: type series N with sealing bellows, color black. Protective collar against unintentional actuation: refer to page 58
More informationPneumatic pressure switch 20DD
Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI
Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationPressure switch for gas and air
Pressure switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF GXX_A4
More informationCompact pressure switches for gas and air
Compact pressure es for gas and air / 5.0 Printed in Germany Edition 0.8 Nr. 9 544 6 Technical description The pressure is an adjustable compact pressure according to EN 854 for combustion plants. The
More informationEX-RECESSED CEILING LIGHT FITTINGS
EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic
More informationTightness controls TC 1 3 and TC 4
Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems
More informationPressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
More informationMECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET
CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS GENERAL CHARACTERISTICS CONSTRUCTION FEATURES ENCLOSURE OPERATING TEMPERATURE 20 C/+60 C COVER Diecast aluminium (anodised) WEIGHT CSN 5 3.5 kg CSN 8 5 kg CSN
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or
More informationQPL... Pressure Switches. Siemens Building Technologies HVAC Products
7 221 Pressure Switches QPL... The pressure switches are used for monitoring gas or air pressures. When the pressure falls below the switching point, the associated electrical circuit will open or switch
More informationIP65 Air Differential Pressure Switch
Page 1 of 5 PA-DPS-9x IP65 Air Differential Pressure Switch Features: Benefits: Close switching differential IP65 Housing Duct fixing kit included Switching point easily adjusted with scale in One screw
More informationExpert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationLevel switches Series LD Vibrating fork level switch for liquids and solids
Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant
More informationPressure controls for hydro carbons, zone II applications, Type KPE
MAKING MODERN LIVING POSSIBLE Technical brochure Pressure controls for hydro carbons, zone II applications, Type KPE KPE pressure controls for use in refrigeration and air conditioning systems with hydrocarbons
More informationEXH. Specifications. Descriptions. Min. working pressure MPa
Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition
Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection
More informationPressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview
f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationGas Pressure Switch for DMV safety shutoff valves
Gas Pressure Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL File # MH 668 CSA Certified CSA C. No. LR File # 07 FM Approved Class 0, 0 File # J.I. Y9A9.AF Commonwealth of Massachusetts
More informationJunction Boxes Series 8118
> Enclosure in glass fibre reinforced polyester resin > 3 different sizes available with 4, 5 or as a junction box with integrated miniature fuse: 3 terminals and 1 miniature fuse 7 terminals and 1 miniature
More informationF series Foot Switches
F series Foot Switches ITC presents a complete line of foot switches from Bernstein, designed to respond to the most stringent requirements for machine control and safety applications. The F series includes
More informationPressure independent control valve (PICV) FLOWMATIC
Pressure independent control valve (PICV) FLOWMATIC 145 series FM 21654 003 01262/19 GB replaces dp 01262/17 GB Function The pressure independent control valve is a device composed of an automatic flow
More informationDifferential pressure control and flow limiter AVPB/AVPB-F, PN 16
Data sheet Differential pressure control and flow limiter AVPB/AVPB-F, PN 16 Application AVPB is a self-acting differential pressure control and flow limiter primarily for use in district heating systems.
More informationASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom
NE ASM Asynchronous Spindle Motors SEM Limited Faraday Way Orpington, Kent BR 3QT United Kingdom Tel: +44 ()189 8847 Fax: +44 ()189 884884 Email: sales@sem.co.uk Web: www.sem.co.uk Version 4 August 2 Asynchronous
More informationThe Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure
General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal
More informationPressure switch Type BCP
Data sheet Pressure switch Type BCP The BCP type is a series of dedicated switches for safety and monitoring of steam and hot water boilers. The BCP incorporates a single-pole changeover microswitch where
More informationPressure controls, differential pressure controls type RT
Data sheet Pressure controls, differential pressure controls type RT Introduction Features An RT pressure control contains a pressure operated single-pole changeover contact, the position of which depends
More informationGas Pressure Switch for DMV safety shutoff valves
Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts
More informationTechnical explanations for mechanical pressure switches
Technical explanations for mechanical pressure switches 7 6 5 4 7 5 6 4 Diaphragm pressure switch NO Piston pressure switch NC Change over 3 2a 1 3 2b 10 9 What is a mechanical pressure switch? Mechanical
More informationDMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.
Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:
More informationMeta-MEC Manual Motor Starters
Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationGlass tube flowmeters Series 2000
Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Short mounting length and compact construction, especially indicated for control panels Easy installation. No
More informationHYDRA-line. HYDRA-Gauges Ultra High Purity Pressure Gauge Model HG. Pressure Systems. Applications. Special features. Description
Pressure Systems HYDRA-Gauges Ultra High Purity Pressure Gauge Model HG WIKA Data Sheet SP 99.20 Applications Semiconductor industry UHP-liquid chemicals distribution Special features Patented double diaphragm
More information9700 Transmitter Submersible hydrostatic level transmitter
Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous
More informationSeries K Air service units G 1/8, G 1/4
Air service units G /8, G /4 Series FK Filter, G /8 G /4.02 Series RK Pressure regulator, G /8 G /4.04 Series FRK Filter/regulator, G /8 G /4.06 Series OK Lubricator, G /8 G /4.08 Series FROK Two piece
More informationTechnical Data. Dimensions
00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable
More informationOperating Instructions
LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.
More informationSPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection
SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces
More information2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure
Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationGas Pressure Switch for DMV safety shutoff valves
Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts
More informationPressure switch Model PS01
Mechatronic pressure measurement Pressure switch Model PS01 Switzer data sheet PS-PS01 Applications Hydraulics and pneumatics Steel Power Special purpose machine Special features Diaphragm-sealed piston
More informationDiaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34
Pressure Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34 WIKA data sheet DS 95.18 Applications Chemical/petrochemical industry, oil/gas industries
More informationDiaphragm pressure switches, 42 V
0166 Diaphragm pressure switches, 42 V Zinc-plated steel body With push-on terminals Overpressure safe to 300 bar *) 0166 Diaphragm pressure switches Adjustment range Thread Normally open (no) : Normally
More informationTECHNICAL CHARACTERSTICS
and solenoid valves spool version GM - GL series Type of valves with dorsal consumption: GM-...series with integrated connections GL-...series without connections TECHNICAL CHARACTERSTICS Ambient temperature:
More informationLMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.
LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationAVPQ/AVPQ-F, PN 16. Application
Data sheet Differential pressure and flow control AVPQ/AVPQ-F, PN 16 Application AVPQ is a self-acting differential pressure and flow control primarily for use in district heating systems. AVPQ closes
More informationDifferenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar
692 Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle 0 0.1 25 bar E Technical overview The differential pressure transmitter of type series 692 with
More informationOperating Instructions Rope Pull Switches RPS...
Safety rope pull switch RPS Correct use In accordance with EN 60947-5-5, EN ISO 13850, it must be ensured that parts of or complete industrial machines or installations can be stopped as quickly as possible
More informationMiniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800
KROHNE 1/22 7.236.22. GR Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 8 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationDifferential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting
Data sheet Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Description AVPQ is a self-acting differential pressure and flow controller primarily for use in
More information2-port seat valves PN25 with externally threaded connections
4 379 2-port seat valves PN25 with externally threaded connections VVG55.. Valve body bronze CC491K (Rg5) DN 15...25 (½...1 ") kvs 0.25...6.3 m3/h Stroke 5.5 mm Sets of ALG.. with threaded and ALS.. with
More informationOperating Instructions
Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table
More informationAVP-F. p setting range (bar) Code No. 003H6200
Data sheet Differential pressure controller (PN 16) AVP - return and flow mounting, adjustable setting AVP-F - return mounting, fixed setting Description The controller has a control valve, an actuator
More informationPILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R
PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is
More informationExpansion Thermometers Stainless Steel Series, Model 70
Mechanical Temperature Measurement Expansion Thermometers Stainless Steel Series, Model 70 WIKA Data Sheet TM 81.01 Applications General-purpose temperature measuring instruments for gaseous, liquid and
More information44 CE RANGE WATERTIGHT SURFACE-MOUNTING JUNCTION BOXES
WALL BOXES IN GWPLAST 75 - GWT 650 C GWT 650 C TP 85 C WALLS WITH CABLE GLAND - IP44 AND IP55 GW44001 JUNCTION BOXES WITH PLAIN PRESS-ON LID - IP44 - GREY RAL 7035 LxHxD (mm) No. holes / Ø GW 44 001 Ø
More informationProp. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08
Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size