Certificate of Conformity

Similar documents
Certificate of Conformity

Certification of EXPLOSION PROTECTED ELECTRICAL EQUIPMENT

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar)

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE

February Cable glands For general industry and hazardous areas

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres

Junction Boxes Series 8118

Operating Instructions

Operating Instructions

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Operating Instructions

PEPPERS CABLE GLANDS.

IECEx Certificate of Conformity Annexe

Conductor Bushings Series 8174

IECEx Certificate of Conformity

NZQA registered unit standard version 2 Page 1 of 7. Conduct a conformity assessment of explosion-protected apparatus

Electro-Pneumatic Converter YT-940 SERIES

Cable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.

IECEx Cert f cate of Gonform ty. IECEX SIR ' X issue No.:1 9-e j{ca!ells_tgryi _ lssue No. 1 ( ) lssue No.

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

Cable entries. Contents. Cable entries. Cable entries Introduction C.2 C.1. Standard cable glands - Plastic C.6. Standard cable glands - Brass C.

Manual Power relay SR853

Cable Glands. Special Applications. RoHS Compliance. Plastic & Metal Cable Glands Adapters Reducers & Enlargers Grommets & Accessories

The evolution of the Ex-proof flame path

IECEx Certificate of Conformity

Arran LED Floodlight Luminaire

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

CABLE GLANDS. Connector~Tech Providing Harsh Environment Connector SOLUTIONS

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

NZQA registered unit standard version 3 Page 1 of 6

IECEx Certificate of Conformity

Pressure Measurement Single-range transmitters for general applications

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Further technical information is available on

ATH-EXx. B Operating Instructions

Pressure switch, Differential pressure switch and Thermostat RT-E

Technical Data. General specifications. Rated operating distance s n 2 mm

FTR Series Track Roller Assembly Flanged Stud Type Concentric Ball & Tapered Roller Bearings

SITRANS P measuring instruments for pressure

Heavy Duty Pocket Insets for the Oil & Gas Industry

4/2 way Pneumatic Solenoid Valve

PTR Series Track Roller Assembly Plain/Cylindrical Stud Type Concentric Ball & Tapered Roller Bearings

Explosion Protection Technology Pty Ltd

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

IECEx Certificate of Conformity Annexe

High Pressure Equipment Taper Seal Valves, Fittings and Tubing

Actuating elements for ComEx

Certificate of Compliance

XCE: Explosionproof Control Enclosures

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Magnetic level switch type MR783 Instruction Manual

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

ComEx Actuating elements

Torque Specifications

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Infrared Linescanners

Pressure control, differental pressure control and thermostat Type RT

VTRE Series Track Roller Assembly V-Grooved Stud Type Eccentric Ball & Tapered Roller Bearings

ATH-EXx. B Operating Instructions

W E NE E D TO TA LK A BOUT COLD FLOW. The Problem With The Cold Flow Standard.

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Certificate of Compliance

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

PTRE Series Track Roller Assembly Plain/Cylindrical Stud Type Eccentric Ball & Tapered Roller Bearings

RTD Temperature sensor TH11

Diaphragm Accumulators

Technical Guideline for Selection of Cable Gland

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

Certificate of Compliance

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

SEALED CONNECTORS FOR THE LIMIT SWITCHES

@h..p. lntertek. IECEx Certificate of Conformity

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Explosion Protection Technology Pty Ltd

EX-RECESSED CEILING LIGHT FITTINGS

4400 TwinHybrid Gas Seal

120 Series Explosion-Proof Pressure and Differential Pressure Switches

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Technical Data. Dimensions

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

TYPE 7800 SERIES 7848D/7848W UNIVERSAL VESSEL SEAL Technical Specification

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

Inductive slot sensor

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

slra of Gonformity IECEx Cert f cate )ol4- ob cst

PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS

Pressure Transmitter P41

AIDGC PRESENTATION MARCH 2006 HAZARDOUS AREAS STANDARDS & CLASSIFICATION

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing

UHrasonic Sensor VEGASON60 type series SN6*.CI**H***

3/8" Dr. Air Butterfly Impact Wrench

Transcription:

Certificate of Conformity Certificate Holder: CCG Cable Terminations (PTY) LTD 33 37 Forge Road Spartan Industrial Area, Kempton Park 1619 SOUTH AFRICA Electrical Apparatus: A2F, A2FX, and A2FCG Cable Gland Range Type of Protection: Ex d, Ex e, Ex nr and Ex td A21 Marking Code: ANZEx 09.4079X Ex d IIC, Ex e II Ex nr II Ex td A21 IP66/67/68 (2m) Manufacturing Location(s): CCG Cable Terminations (PTY) LTD 33-37 Forge Rd Spartan Industrial Area, Kempton Park 1619 SOUTH AFRICA ABN 60 098 886 563 Certificate issued by ITACS Pty. Ltd. 4-6 Second Street SA 5007 Australia PO Box 300 Hindmarsh SA 5007 Australia Phone: +61 8 8346 8680 Fax: +61 8 8346 7072 Email: itacs@itacslab.com Accreditation by the Joint Accreditation System of Australia and New Zealand Acc No. Z2870404AA www.jas-anz.org Page 1 of 12

This certificate is granted subject to the conditions as set out in Standards Australia/Standards New Zealand Miscellaneous Publication MP87.1:2008 STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: AS/NZS 60079.15:2006 AS/NZS 60079.0:2005 AS/NZS 60079-1:2005 AS/NZS 60079-7:2006 AS/NZS 61241-0:2005 AS/NZS 61241-1:2005 AS 1939-1990 Electrical apparatus for explosive gas atmospheres Part 15 Construction, test and marking of type of protection, n electrical apparatus Electrical apparatus for explosive gas atmospheres Part 0: General requirements. Electrical apparatus for explosive gas atmospheres Part 1: Flameproof enclosures d Electrical apparatus for Explosive atmospheres Part 7: Equipment protection by increased safety e Electrical apparatus for use in the presence of combustible dust Part 0: General requirements. Electrical apparatus for use in the presence of combustible dust Part 1: Protection by enclosures td Degrees of protection by enclosures of electrical equipment (IP Code) This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. Attention is drawn to the fact that the above Standards have been superseded. TEST & ASSESSMENT REPORTS: The equipment listed has successfully met the examination and test requirements as recorded in Test Report No. and Issuing Body: ITACS TR 5397 & 19400793.001 Quality Assessment Report No. and Issuing Body: IECEx QAR, ITACS - AU/ITA/QAR08.0002/03 File Reference: ANZ Ex 09.4079X-2 Signed for and on behalf of issuing body Certification Authority 18 th October 2011 Position Date of Issue This certificate is not transferable and remains the property of the issuing body and must be returned in the event of it being revoked or not renewed. Page 2 of 12

EQUIPMENT: Schedule A2F is a single seal compression gland providing sealing and cable retention onto the outer sheath of unarmoured cable. It comprise of a metallic outer compression nut, a skid ring, a tapered displacement seal, a metallic inner body and washer. The glands are available with metric threads and NPT threads. A2FX is a double seal compression gland providing sealing and cable retention at two independent sealing points on the outer sheath of unarmoured cable. It comprises of a metallic outer compression nut, a skid ring and tapered displacement seal, an inner compression nut, an inner skid ring and displacement seal and a metallic inner body with a washer. Glands are available with metric threads and NPT threads. A2FCG is a double seal compression gland providing sealing and cable retention at two independent sealing points on the outer sheath of unarmoured cable. It comprises of a non-metallic outer compression nut, a skid ring and displacement seal locking against a non-metallic body. The non-metallic body covers the whole of the metallic parts and compresses against the washer located against the body of the enclosure. The non-metallic body engages the metallic inner compression nut, skid ring and displacement seal and a metallic inner body with the washer. Glands are available with metric threads. Note: The non-metallic parts provide corrosion protection to the metallic gland and does not form an essential part of the explosion protection. Therefore, the corrosion guard gland is essentially of the same construction / design as the A2F gland (with a single seal), covered by a non metallic shroud and seal. All cable glands hold an IP rating of IP66/IP67/IP68(2m). The models listed in the tables below are covered. Page 3 of 12

Table 1 A2F Gland Gland Size Ref Entry Thread CABLE DETAILS Diameter (Sheath) Thread Type Thread Length (mm Min) Min (mm) Max (mm) (mm) 00-16ss M16 x 1.5 15.0 3.0 8.5 00-20ss M20 x 1.5 15.0 3.0 8.5 0-20s M20 x 1.5 15.0 7.0 12.0 1-20 M20 x 1.5 15.0 11.0 15.5 2-25s M25 x 1.5 15.0 11.5 17.5 2-25 M25 x 1.5 15.0 15.0 20.2 3-32s M32 x 1.5 15.0 16.0 22.0 3-32 M32 x 1.5 15.0 20.0 26.5 4-40s M40 x 1.5 15.0 22.0 31.5 4-40 M40 x 1.5 15.0 26.0 34.5 5-50s M50 x 1.5 15.0 29.0 38.0 5-50 M50 x 1.5 15.0 34.0 44.5 6-63s M63 x 1.5 15.0 38.0 50.0 6-63 M63 x 1.5 15.0 44.0 57.0 7-75s M75 x 1.5 15.0 50.0 62.0 7-75 M75 x 1.5 15.0 56.0 68.0 8-80s M80 x 2.0 20.0 54.0 69.0 8-80 M80 x 2.0 20.0 65.0 74.0 9-90s M90 x 2.0 20.0 60.0 75.0 9-90 M90 x 2.0 20.0 73.0 82.0 10-100 M100 x 2.0 20.0 81.0 92.0 11-110 M110 x 2.0 20.0 91.0 102.0 Page 4 of 12

Table 2 A2F - NPT Gland Gland Size Ref Entry Thread CABLE DETAILS Diameter (Sheath) Thread Type (inch) Thread Length (mm Min) Min (mm) Max (mm) 00-20ss 1/2 15.0 3.0 8.5 00-20ss 3/4 15.0 3.0 8.5 0-20s 1/2 15.0 7.0 12.0 0-20s 3/4 15.0 7.0 12.0 1-20 1/2 or 3/4 15.0 11.0 15.5 2-25s 3/4 or 1 15.0 / 19.0 11.5 17.5 2-25 3/4 or 1 15.0 / 19.0 15.0 20.2 3-32s 1 or 1 1/4 19.0 16.0 22.0 3-32 1 or 1 1/4 19.0 20.0 26.5 4-40s 1 1/4 or 1 1/2 19.0 / 21.0 22.0 31.5 4-40 1 1/4 or 1 1/2 19.0 / 21.0 26.0 34.5 5-50s 1 1/2 or 2 21.0 29.0 38.0 5-50 1 1/2 or 2 21.0 34.0 44.5 6-63s 2 or 2 1/2 21.0 / 30.0 38.0 50.0 6-63 2 or 2 1/2 21.0 / 30.0 44.0 57.0 7-75s 2 1/2 or 3 30.0 / 32.0 50.0 62.0 7-75 2 1/2 or 3 30.0 / 32.0 56.0 68.0 8-80s 3 32.0 54.0 69.0 8-80 3 32.0 65.0 74.0 9-90s 3 or 3 1/2 32.0 / 33.0 60.0 75.0 9-90 3 or 3 1/2 32.0 / 33.0 73.0 82.0 10-100 3 1/2 or 4 33.0 / 34.0 81.0 92.0 11-110 4 34.0 91.0 102.0 Page 5 of 12

Table 3 A2FX Gland Gland Size Ref Entry Thread Cable Details Thread Type Thread Length (mm Min) Min (mm) Max (mm) (mm) 00-16ss M16 x 1.5 15.0 3.0 8.5 00-20ss M20 x 1.5 15.0 3.0 8.5 0-20s M20 x 1.5 15.0 7.0 11.0 1-20 M20 x 1.5 15.0 11.0 15.5 2-25s M25 x 1.5 15.0 11.5 17.5 2-25 M25 x 1.5 15.0 15.0 20.5 3-32s M32 x 1.5 15.0 16.0 22.0 3-32 M32 x 1.5 15.0 20.0 26.5 4-40s M40 x 1.5 15.0 22.0 31.5 4-40 M40 x 1.5 15.0 26.0 34.5 5-50s M50 x 1.5 15.0 29.0 38.0 5-50 M50 x 1.5 15.0 34.0 44.5 6-63s M63 x 1.5 15.0 38.0 50.0 6-63 M63 x 1.5 15.0 44.0 57.0 7-75s M75 x 1.5 15.0 50.0 62.0 7-75 M75 x 1.5 15.0 56.0 68.0 8-80s M80 x 2 20.0 54.0 67.0 8-80 M80 x 2 20.0 65.0 74.0 9-90s M90 x 2 20.0 60.0 75.0 9-90 M90 x 2 20.0 73.0 82.0 10-100 M100 x 2 20.0 81.0 92.0 11-110 M110 X 2 20.0 91.0 102.0 Page 6 of 12

Table 4 A2FX-NPT Gland Gland Size Reference Entry Thread Cable Details Thread Type (inch) Thread Length (mm Min) Min (mm) Max (mm) 00-20ss 1/2 or 3/4 15.0 3.0 8.5 0-20s 1/2 or 3/4 15.0 7.0 11.5 1-20 1/2 or 3/4 15.0 11.0 15.5 2-25s 3/4 or 1 15.0 / 19.0 11.5 17.5 2-25 3/4 or 1 15.0 / 19.0 15.0 20.5 3-32s 1 or 1 1/4 19.0 16.0 22.0 3-32 1 or 1 1/4 19.0 20.0 26.5 4-40s 1 1/4 or 1 1/2 19.0 / 21.0 22.0 31.5 4-40 1 1/4 or 1 1/2 19.0 / 21.0 26.0 34.5 5-50s 1 1/2 or 2 21.0 29.0 38.0 5-50 1 1/2 or 2 21.0 34.0 44.5 6-63s 2 or 2 1/2 21.0 / 30.0 38.0 50.0 6-63 2 or 2 1/2 21.0 / 30.0 44.0 57.0 7-75s 2 1/2 or 3 30.0 / 32.0 50.0 62.0 7-75 2 1/2 or 3 30.0 / 32.0 56.0 68.0 8-80s 3 32.0 54.0 67.0 8-80 3 32.0 65.0 74.0 9-90s 3 or 3 1/2 32.0 / 33.0 60.0 75.0 9-90 3 or 3 1/2 32.0 / 33.0 73.0 82.0 10-100 3 1/2 or 4 33.0 / 34.0 81.0 92.0 11-110 4 34.0 91.0 102.0 Table 5 A2FCG CORROSION GUARD Gland Page 7 of 12

Gland Size Ref Entry Thread Cable Details Thread Type Thread Length (mm Min) Min Max (mm) (mm) (mm) 00-16ss M16 x 1.5 15.0 3.0 8.5 00-20ss M20 x 1.5 15.0 3.0 8.5 0-20s M20 x 1.5 15.0 7.0 11.5 1-20 M20 x 1.5 15.0 11.0 15.5 2-25s M25 x 1.5 15.0 11.5 17.5 2-25 M25 x 1.5 15.0 15.0 20.5 3-32s M32 x 1.5 15.0 16.0 22.0 3-32 M32 x 1.5 15.0 20.0 26.5 4-40s M40 x 1.5 15.0 22.0 31.5 4-40 M40 x 1.5 15.0 26.0 34.5 5-50s M50 x 1.5 15.0 29.0 38.0 5-50 M50 x 1.5 15.0 34.0 44.5 6-63s M63 x 1.5 15.0 38.0 50.0 6-63 M63 x 1.5 15.0 44.0 57.0 7-75s M75 x 1.5 15.0 50.0 62.0 7-75 M75 x 1.5 15.0 56.0 68.0 8-80s M80 x 2 25.0 54.0 67.0 8-80 M80 x 2 25.0 65.0 74.0 9-90s M90 x 2 25.0 60.0 75.0 9-90 M90 x 2 25.0 74.0 82.0 10-100 M100 x 2 25.0 81.0 91.0 Page 8 of 12

Marking Code. The following Marking Code applies: A2F Glands CCG X A2F YYzz ANZEx 09.4079X Ex d IIC, Ex e II, Ex nr II Ex td A21 IP66/67/68 (2m CONT.) A2FX Glands CCG S A2FX YYzz ANZEx 09.4079X Ex d IIC, Ex e II, Ex nr II Ex td A21 IP66/67/68 (2m CONT.) A2FCG Glands CCG X A2FCG YYzz ANZEx 09.4079X Ex d IIC, Ex e II, Ex nr II Ex td A21 IP66/67/68 (2m CONT.) Where X (or S) indicates the gland number e.g. 00 to 11 (see Tables 1-5 above) and Where YY ZZ indicates the gland size (e.g. 16ss to 110) (see Tables 1-5 above) Page 9 of 12

ISSUE 0 AND VARIATIONS PERMITTED BY ISSUE 1 For details refer to previous issues of the certificate. VARIATIONS PERMITTED BY ISSUE 2 1. Additional s size glands in ranges of glands to extend the range to accommodate different diameter cables. 2. Including additional materials for seals and gaskets. 3. Increase of the service temperature of the glands to -20 C to 95 C. 4. Small dimensional corrections / improvements on the gland series. 5. Updating the standards to later series of standards with identical requirements. Full gland series covered by this update. See sheet 2 for list of current Standards. 6. Consolidating the drawings of all revisions into a single set of drawings 7. A condition of manufacture was added and the special conditions of use updated. 8. Updating of marking. Page 10 of 12

CONDITIONS OF CERTIFICATION: Conditions of manufacture It is a condition of manufacture / certification that a copy of the relevant certificate and instructions must be provided with / made available for the glands, including the installation torque. Special conditions of use a) The cable glands are only to be used on fixed installation of Group II apparatus: The end user is to ensure that adequate clamping of the cable has been made. b) Cable glands are not to be installed on Ex d group IIC equipment which has a free internal volume of more than 2 litres. c) Cable Glands are only to be used with the sealing ring, o-ring and gasket provided by the manufacturer. d) The option of using the gland in a non-threaded hole secured with a locknut is only applicable to increased safety, restricted breathing or dust ignition proof applications, providing IP54 (Ex e), IP65 (Ex td) or restricted breathing is maintained as applicable and in accordance with the manufacturer s instructions. e) The service temperature range of the gland must be within -20 C to +95 C DRAWINGS: Drawing Schedule Relating to Issue 2: Drawing No. Drawing Title Rev. Date 0540-M No. M A2F GLAND 4 11/09/23 0540-A No. M A2F GLAND 3 11/09/19 05400-05411-O No. M A2F OUTER 00-11 3 11/09/20 05400-054011-I No. M A2F INNER 2 11/09/20 0540-GS No.00 TO 11 A2F GRIPPER SEAL 4 11/09/19 0540-W No. M A2F WASHER 2 11/09/19 0540-SR No. M A2F SKID RING 3 11/09/19 0540-OR A2F O RING 00-11 3 11/09/19 Page 11 of 12

Drawing No. Drawing Title Rev. Date 0540-NPT-M A2F GLAND MATERIALS 2 11/09/23 0540-A-NPT A2F NPT CABLE GLAND 3 11/09/19 05400-054011-I-NPT No. M A2F INNER 1/2 NPT 4 NPT 3 11/09/20 0542-M A2FX GLAND MATERIALS 1 11/08/07 0542-A No. X A2FX GLAND 1 11/09/20 054016-O-054011-O No. M A2FX OUTER 1 11/09/20 0542-A-NPT No. X A2FX GLAND 1 11/09/20 0541-M A2F CORROSION GUARD MATERIAL 2 11/09/23 0541-A No. M A2F CORROSION GUARD 1 11/09/19 0542016-O-0542011-O No. M A2FX CORROSION OUTER 1 11/09/20 E.00.00.48.000/BODY-ASSY EXCG BODY COMPONENTS 5 11/08/07 054700-OS 054710-OS No X EXCG OUTER SEAL 4 11/08/07 054700-SR 054710-SR No.00 TO No.10 EXCG SKID RING 4 11/08/07 054700-SG 054710-SG No.00 TO No.10 EXCG GASKET 3 11/08/07 0540-Marking A2F GLAND MARKING 6 11/09/22 0541-Marking A2FCG GLAND Marking 9 11/09/22 0542-Marking A2FX GLAND MARKING 9 11/09/22 Page 12 of 12