Analysis A1 and B2 Methods of Hydrostatic Testing Applied at Gas Pipeline; Cause Study A1-Method

Similar documents
OCTOBER 2017 ISSUE Page 1 of 7

SECTION PRESSURE TESTING OF PIPING

Subpart E. Pressure Testing

Safety. April 2018 Supersedes all previous publications 2018 Chevron Phillips Chemical Company LP

Casing Spacer Technology Leaders

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Standard Pneumatic Test Procedure Requirements for Piping Systems

Hydrostatic Pressure Testing Plan

Hydrostatic Pressure Testing

Self-operated Pressure Regulators for special applications

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

HYDROSTATIC LEAK TEST PROCEDURE

Pressure Reducing Valve for Steam Type 2333 A

Pipeline Systems PIP PLSC0019 Specification for Pressure Testing HDPE Plastic Pipeline Systems

PE 2708 CTS & IPS GAS PIPE

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints

Appendix C Field Testing of Pipelines

WELCOME to CAUx Local India 2018

San Antonio Water System Standard Specifications for Construction ITEM NO. 841 HYDROSTATIC TESTING OPERATIONS

Rules for the Installation, Inspection and Testing of Air Reservoirs (Other than on Locomotives)

Annex to the Accreditation Certificate D-IS according to DIN EN ISO/IEC 17020:2012

Pressures MAOP MOP OP

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

Part 192 Subparts J & K. Testing & Uprating

REFER TO AQUATHERM TECHNICAL BULLETIN A-AQTTB FOR ADDITIONAL INFORMATION AND SAFETY PRECAUTIONS

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL)

Design and Analysis of Pressure Safety Release Valve by using Finite Element Analysis

Instruction Manual Contact Pressure Vacuum Gauge

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

PIP PNE00012 Piping Examination and Leak Test Guide

WATER METERS.

ACS.TPCP1 SAFETY ASSESSMENT CRITERIA INITIAL AND RE-ASSESSMENT NON-DOMESTIC NATURAL GAS; LPG; OTHER GASES TESTING AND PURGING

DESIGN AND ANALYSIS OF PRESSURE VESSEL

Pressure Independent Control Series

2003 WJTA American Waterjet Conference August 17-19, 2003 Houston, Texas Paper PIPE THREADS-WHAT IS THE LIMIT?

F-08 HIGH-PRESSURE HOSE USED IN CO2 SYSTEM

Bermad Pressure Reducing. Model: 42T

776 Cryogenic Safety Valve

Liquefied gas cargo tanks and process pressure vessels

Flange Bolt Torquing. for Resistoflex Plastic-Lined Piping Products. Torquing. Retorquing. Hydrotesting. Annual retorquing

Use equation for the cylindrical section and equation or for the ends.

Hydrostatic Testing of In-Situ Pipelines & Spike Testing. Colin Silla, PE, PMP Southeast District Manager 6/27/18

INTRODUCTION TABLE OF CONTENTS

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Models 106-RF / 206-RF Rate of Flow Control Valve

ASYBCO 90 O ELBOW LONG RADIUS O.D. I.D.

HON 219 Pressure Reducer (D119a)

The Powerful Sealing Calculation

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

Contents. 1. Non Destructive Testing Requirements. 2. Non Destructive Testing Methods Magnetic Particle Examination

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Irrigation System Winterization and Pressurization Procedures

VACUVENT VE SERIES CATALOGUE

Module 6. Tightness Testing

The Discussion of this exercise covers the following points:

Casing Collapse Pressure for Non-zero Internal Pressure Condition. (Effect of Internal Pressure on Collapse)

Structurals Rationalised sizes of Beams/Joists, Channels and Angles

Pressure and Flow Control Valves DBGM, German and European Patents

AVP-F. p setting range (bar) Code No. 003H6200

Structural Design and Analysis of the New Mobile Refuge Chamber

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Mounting and Operating Instructions EB EN. Self-operated Pressure Regulators. Type 2335 Excess Pressure Valve with pilot valve

Installation and Operating Instructions Bypass Flow Meter DST

SECTION 25 TESTING AND DISINFECTING WATER MAINS General

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

Gas Pressure Regulator HON 300

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

SECTION BUTTERFLY VALVES

PVP Copyright 2009 by ASME

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

Technical Data Sheet T 2025

Safety Shut-Off Valve HON 720

Automatic balancing valves ASV

CERTIFICATION OF COMPLIANCE OF THE USER S DESIGN SPECIFICATION

MSC Guidelines for Independent Fuel Tanks

Pressure Relief Valve DHV 718

Analysis of Shear Lag in Steel Angle Connectors

Flowmeter. Original operating manual DFM

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

Homework 2 PROBLEM No. 1

Date of Issue: July 2016 Affected Publication: API Specification 16C, Choke and Kill Equipment, Second Edition, March 2015 ADDENDUM 1

Smart Water Application Technologies (SWAT) TM

Remotely-installed Hydraulic Module

DGZfP-Proceedings BB 90-CD Lecture 4 EWGAE 2004

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

I. CHEM. E. SYMPOSIUM SERIES NO. 85

Automatic balancing valves ASV

756 Safety Relief Valves

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Installation, operation & maintenance manual - original version

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Gas Pressure Regulator HON 200

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Transcription:

Analysis A1 and B2 Methods of Hydrostatic Testing Applied at Gas Pipeline; Cause Study A1-Method Alfred HASANAJ Abstract in this paper we will analyze methods of hydrostatic testing applied in Trans Adriatic Pipeline Project. According to DVGW469 test methods applied in this project we have: A1, A2 and B2. We will analysis the A1 Test Method,which is applied to sections that are subject to be re-tested after being laid in final position as part of the main line testing, e.g. HDD crossings, RDX, RVX,AGI etc.. Another method for testing pipeline is A2 Test Method, which is applied to exposed sections and is the final hydro test and are not subject to be re-tested again. Also another method that we will be apply in this project is B-2 Test Method that is applied to buried sections and no access over the whole section for visual leak. Our study consist in Pre-test Horizontal Direction Drilling Section in SEMAN River Crossing at Kp198 using A1 method,the outside diameter of this section is 48",wall thickness 24.9 mm, length 1129.94 mm, volume 1219.56 m 3. After filling the section with water we start pressurization no more than 3 bar/min, where pressure is meassured by dead weight tester and indiceted by pressure recorder. The minimum test pressure was 123.5 bar, max test pressure 152 bar and strength test pressure 144 bar. After pressure in the section reaches test pressure we start stabilization time. When pressure reached 144.170 bar, no leak was founded during the visual check after 4-hour pressure holding time. When the holding time is up, we start depressurization by no more than 3-5 bar/min after this test came to an end. Finally, we accepted this pre-test because in the best test period chosen we had a differences on the temperature of -0.6454 C, for a temperature decrease we must have a pressure decrease, in our test period we have a pressure decrease of -0.59 bar, which means that a correct ΔP/ΔT behavior for the section tested. In addition, for this test section we have a maximum ΔP/ΔT= 1.3494 Bar/ C. The ΔT of the test period is -0.6454 C, where the allowed pressure decrease is -0.8709 Bar, at the final of the test period we received a ΔP of -0.59 bar which s is less than 0.8709 bar, the test is between the accepted ranges. As result test is accepted. Index Terms DVGW469, A1 Test Method, HDD section, Dead Weight Tester, Pressure Recorder. I. DESCRIBE METHODS OF HYDROSTATIC TESTING APPLIED AT GAS PIPELINE We will describe A1 and B2 methods of hydrostatic testing based on to DVGW G469. A 1 METHOD The test pressure is defined by the DVGW Technical Rules applying to the pipeline or installation. The Test pressure shall be specified prior to testing but must not exceed 95% of the minimum proof stress Rt 0.5 of the pipelines and/or installation components as per DIN 30690 Part 1 at the lowest point of the pipeline. The test pressure shall be at least 1.3 times the maximum permissible operating pressure at the highest point of the pipeline. After filling and de-aeration (cf. 3.3), the test pressure shall be applied with a pressure increase of up to 3bar/min max., and shall, as a general rule, be held for 3 hours in pipelines and installations. The holding time may be reduced for installation assemblies in accordance with DIN 30690 Part 1 and pipelines in accordance with DVGW Code of Practice G 496. During the holding time, in particular the connections and fixtures (flanges, socket joints, fittings, etc.) of the pipeline or installation assemblies shall be tested for tightness. The A 1 method is one pressurization interval+ 4-hour leak test. Test Method is applied to sections which are subject to be re-tested after being laid in final position as part of the main line testing, e.g. HDD crossings, RDX, RVX). The hydro test is carried out before the section is laid in final position to verify the section has passed the strength test and is free of leaks. The pre-hydrostatic strength test and leak test pressure shall be slightly higher than the test pressure at the location when re-tested during the main line testing. The 4-hour leak test may be continued at the strength test pressure carried out at a reduced pressure as long the test pressures are higher than the expected test pressure when re-tested. Volume controlled pressurization is only required when the test pressures raise above 95% SMYS. Section can be water filled with the free-flooding method providing the air can be vented-off at a high point, or one bi-direction pig is pushed with water for air free water filling of the section. Air entrapment 14

calculation is not required. The acceptance criteria: No leak is found during the visual leak check after the 4-hour pressure holding time. 1. Pressurization to 80 % of Test Pressure 2. 20 min stabilization 3. Pressurization to 100% of Test Pressure 4. Minimum 4 hours holding time and Perform Visual Check 5. Depressurization Pressure 100%TP 4 80%TP 2 3 1 5 Fig 1: Pressurisation Sequence Method A-1 B 2 METHOD Testing Method: Two Pressurization Intervals + 24-hour leak test. The B-2 Test Method is applied to buried sections. It applies to sections with no access over the whole section for visual leak. The tightness of the test section is checked by evaluating the temperature-dependent fluctuations in pressure compared to the measured pressure differences over a minimum of 24-hour continuous testing time. The maximum strength test pressure is equivalent to 95% of SMYS with the exception in higher elevated areas to <100% SMYS pressure but shall never be less than 1.3 x MOP of each pipe at the location. The minimum leak test pressure is 1.1 x MOP but shall not exceed the strength test pressure applied to this section. After completion of water filling and sufficient time allowed for water temperature stabilization Test section is ready for pressurization. Pipeline temperatures will be obtained for proof of stabilization of filling water temperature and for calculating the theoretical volume necessary for raising 1 bar pressure. The maximum test pressure is equivalent to <100% SMYS (E.g. 99.9%).At test pressures exceeding 95% SMYS, a quick-pressure-release-valve is installed in the pressurizing system which can be remote opened if necessary, e.g. in the unlikely event of pipe yield. 1st Pressurizing Interval The pressurization shall be at a rate of not exceeding 3 bar per minute and stop at 100% test pressure. The pump rate, once established, shall be maintained to avoid pressure surges in the test section which can cause instable pressure/volume readings. The test pressure is held for 90 minutes. During this time the test pressure is logged every 15minutes and pressure values are transferred on a pressure decay plot. Upon completion of the 90-minute pressure holding time, the test pressure is decreased at a rate not exceeding 3-5 bar per minute to a pressure not lower than 2-5 bar at the high point. 2nd Pressurizing Interval Same method is followed as during the 1st pressurization interval. Time 15

Determine Air Content The air contend is calculated during the pressurization to test pressure by comparing the theoretical Volume vs actual volume injected per pressure increase at 80% test pressure. The actual injected volume is measured by a high precision flow meter and transmitted to the test control cabin.the difference between the actual and theoretical data shall no exceed the factor 1.06 (6%).Optional a Drain-Test can be used for determine the air content. The Test pressure is recorded during all time on end-less paper roll by means of a mechanically clockwork operated pressure recorder. Pressure gauges are installed inside and outside the test cabin and indicating at all time the pressure status of the test section. Fig 2: Pressurisation Sequence Method B-2 Leak Test Pressure Holding Period for Leak Test After completion of the second 90-minute holding time the Test Engineer shall decide whether to continue with the leak test at the same pressure (strength test pressure) or at a lower pressure. A lower test pressure shall consider the head pressure to the high point and the expected effect of temperature change on test pressure, to ensure that the leak test pressure is not falling below the minimum test pressure at the section high point. The minimum leak test pressure is 1.1 x DP at the high point. Once the leak test has commenced the test data shall be recorded for a minimum continuous time of twenty-four (24) hours. Acceptance Criteria The permissible unaccountable volume change is regulated by the equation: 4xV ri /3000= litre/hour The maximum value is limited to 4 litre/hr regardless of the Section volume. If the temperature corrected pressure loss is greater than the unaccountable, an assessment will be conducted to determine if there is a leak. This may be achieved by continuing the assessment of the test over a longer period of time. If a leak is determined, the location will be identified and repair undertaken. Pipeline Details Subject Service Nominal Pipe Size / Outside Diameter Nominal Wall Thickness Design Pressure Inside Diameter II. A1 METHOD-CAUSE STUDY Detail HP Gas Pipeline 48 / 1219 mm Outside Diameter 17.5mm / 21.0mm / 24.9mm / 30.9mm 95 bar 1184.0mm /1177.0mm /1169.2mm /1157.2mm 16

Pipeline Material Material Grade Specified Minimum Yield Strength(Rt0.5) Specified Maximum Yield Strength (Rt0.5) Specified Minimum Tensile Strength (Rm) Specified Maximum Tensile Strength (Rm) Design Pressure Carbon Steel X70ME / L485ME 485 N/mm2 605 N/mm2 570 N/mm2 690 N/mm2 95 bar Design Temperature Minimum -20 C / max. + 60 C HDD Section Approx. Length (m) Approx. Volume (m) HDD Semani River (KP 198) 1111.74 1194.4 HDD Semani River (KP 198) with test headers 1123.74 1206.64 Test pressure Minimum test pressure = 1.3 x Design Pressure=1.3 x 95 Bar=123.5 Bar (on the highest point of the section) Maximum test pressure = ((2 x Minimum Yield strength x Wall thickness)*0.95) / ED= ((2 x 486 x 24.99)x0.95)/1219.2)x10=189.2 bar (on the highest point of the section). Depends on the start time of the test, should be between the maximum and minimum at the highest point of the test section. Test instrumentation - 1 Dead Weight Tester (Budenberg 5400 EP) - 2 Dial Pressure Gauge ( Anti parallax mirror) 0-250 Bar - 2 Magnetic Pipe Temperature Sensors - 1 Ambient temperature thermometer Filling pump Gauge Water Test Header 2 Test Header 1 High pressure pump 1111.74 m 48" wt 24.99 gr. X70ME Pipeline Magnetic Pipe Temperature Sensor Magnetic Pipe Temperature Sensor Gauge Dead Weight Tester Results of the Test: Graph Pressure vs Time Fig 3: Instrument scheme 17

Fig 4:Pressure vs Time Fig 5: Graph: Pressure vs Average Wall Temperature 18

Fig 6:Graph :Delta P vs Delta T From KP: Weld No.: Pipeline Details Pressure Test Parameters Length (m): 1129,94 Strength Test Pressure Bar: 144 O.D. (inches): 48 Minimum Test Hold Period: 3 hours I.D. (mm): 1169,4 Leak Test Pressure KPa: - 198+000 To KP: 199+130 Minimum Test Hold Period: - KP 198/J-1 Weld No.: KP 198/J-60 Pressurization Start: Date: 21/11/2016 Time: 19:33 Pressure: 50 Bar 100% Test Pressure Attained: Date: 21/11/2016 Time: 21:47 Pressure: 144.170 Bar Strength Test Hold Period Date: 22/11/2016 Time: 00:00 Pressure: 143.745 Bar Commenced: Strength Test Hold Period Date: 22/11/2016 Time: 03:00 Pressure: 142.920 Bar Completed: Depressurization Commenced: Date: 22/11/2016 Time: 03:45 Pressure: 142.860 Bar III. CONCLUSION We accepted this pre-test because no leak founded during 4 hours holding time and in the best test period chosen we had a differences on the temperature of -0.6454 C, for a temperature decrease we must have a pressure decrease, in our test period we have a pressure decrease of -0.59 bar, which means that a correct ΔP/ΔT behavior for the section tested. In addition, for this test section we have a maximum ΔP/ΔT= 1.3494 Bar/ C. The ΔT of the test period is -0.6454 C, where the allowed pressure decrease is -0.8709 Bar, at the final of the test period we received a ΔP of -0.59 bar which s is less than 0.8709 bar, the test is between the accepted ranges. As result test is accepted. 19

REFERENCES [1] BROOKS, L. E., Hydrostatic Testing of Pipe Lines, Journal of the Pipeline Division of the American Society of Civil Engineers, Vol. 83, No. PL3, September 1957. [2] EN1594:2009 - Gas supply systems Pipelines for a max operating pressure over 16 bar- Functional requirements. [3] EN12327:2000 - Gas supply systems - Pressure testing, commissioning and decommissioning procedures. Functional requirements. Remark: The German standarden12327 is referring to the DVGW Regelwerk G469 and this is referring to VdTÜV Merkblatt 1060. [4] DVGW Regelwerk G469: 2010 Druckprüfverfahren Gastransport/Gasverteilung. [5] ISO 3183: (last edition), Petroleum and natural gas industries Steel pipe for Pipeline transportation systems; EN 12327: (last edition) Pressure Testing, functional requirements. AUTHOR BIOGRAPHY Alfred HASANAJ was born in Fier Albania in 1988. He earned the MSC degree from the University Polytechnic University of Tirana majoring in Mechanical Constructions and Moving Vehicles, 2012.He was graduated from Northumbria University Newcastle Upon Tyne, United Kingdom in Pipeline Integrity Management, and currently he is following the PhD studies topic: "Assessment integrity of gas pipeline Cause study TAP-Project ". At the preset he works as Hydro test Engineer at Trans Adriatic Pipeline Project. He is continuing research on the mechanics specifically in gas pipe related fields. 20