Table of contents. I Drawings 33. A1 Design criteria 1 A1.1 Local thermal discomfort indices... 1

Similar documents
Effect of airflow direction on human perception of draught

THE AIRCRAFT SEAT AS INDOOR AIR QUALITY AND TEMPERATURE CONTROL SYSTEM

CFD Modeling of Thermal Manikin Heat Loss in a Comfort Evaluation Benchmark Test

REQUIREMENTS AND HAND-OVER DOCUMENTATION FOR ENERGY-OPTIMAL DEMAND-CONTROLLED VENTILATION

CORESTA RECOMMENDED METHOD N 6

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

Thermal Conditions in a Simulated Office Environment with Convective and Radiant Cooling Systems

Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations

WP2 Fire test for toxicity of fire effluents

Cross Infection in Hospital Wards with Downward Ventilation - Different Locations of Return Openings without and with Partitions between Beds

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

APPENDIX A SAMPLE FHT SPECIFICATION (This recommended FHT specification is available from

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Mott Manufacturing Limited

Aerodim TM The new aerodynamic silencer reduces sound by half

Validation of a Neutral Pressure Isolation Room

Group Quality Certification System of Performance Test for Clean Rooms (CR Mark)

Single-sided Natural Ventilation Driven by a Combination of Wind Pressure and Temperature Difference Larsen, Tine Steen; Heiselberg, Per Kvols

THE EXAMINATION OF COMFORT AND CROSS INFECTION IN A DISPLACEMENT VENTILATED ROOM

VENTILATION EFFICIENCIES OF A DESK-EDGE-MOUNTED TASK VENTILATION SYSTEM

CHAPTER 3 RESULTS AND DISCUSSION

Keywords: Chilled beam, Thermal plume, Air diffusion, Draught risk

Astudy of the air quality in the breathing zone in a room with displacement ventilation

How to Test Air Change Effectiveness

Universities of Leeds, Sheffield and York

MEASURING AIR FLOW. Ventilation (Outside Air) Calculations. Derive % of OA as part of total air flow using air temperatures:

INTERPRETATION IC OF ANSI/ASHRAE STANDARD VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY

Statesville, NC. Results of AM ASHRAE 110 Laboratory Fume Hood Performance Evaluations Venturi Hood

STANDARD PROCEDURE OF A TIGHTNESS TEST OF A SOLAR COLLECTOR BOX. (EUROSUN 2000 SOLAR CONGRESS)

Exp. 5 Ideal gas law. Introduction

Outside Air Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program

Measurement of Air Flow Rate in a Naturally Ventilated Double Skin Facade Larsen, Olena Kalyanova; Jensen, Rasmus Lund; Heiselberg, Per Kvols

Automatic Isokinetic Sampler. ST5 Evo

ANALYSES OF THERMAL COMFORT AND INDOOR AIR QUALITY UNDER STRATUM, DISPLACEMENT, AND MIXING VENTILATION SYSTEMS

This test shall be carried out on all vehicles equipped with open type traction batteries.

Biography. Abstract. Keywords. Body box, garments, validation, calibration, clean garments, IEST-RP-CC003.3, garment. Introduction and Scope

Results of Field Measurements and CONTAM Simulation. Building Science

Cover Page for Lab Report Group Portion. Pump Performance

01 18/11/2013 correction of the reference of the product 1 4 5

Boyle s Law: Pressure-Volume Relationship in Gases

Anemometry. Anemometry. Wind Conventions and Characteristics. Anemometry. Wind Variability. Anemometry. Function of an anemometer:

AIRFLOW AND TEMPERATURE FIELD CALCULATIONS FOR WINTER SPORTS FACILITIES

WBEA Standard Operating Procedure

FLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN

VAV SYSTEM INDOOR AIR QUALITY CONSIDERATIONS FOR OFFICE SPACES

Methods of Test for Determining Application Data of Overhead Circulator Fans

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A

Manual of SF6 Comprehensive Tester

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

International Journal of Research in Advent Technology Available Online at:

BERNOULLI EFFECTS ON PRESSURE.ACTIVATED W ATER LEVEL GAUGES

USER'S MANUAL HOT-WIRE TYPE GAS SENSOR NAP-100A SERIES ( NET10A(R) ) (For All Combustible Gases)

Testing the Vented, 2-Liter Induction Chamber. Report 14 October 2004

AC : ACCURATE CRYOCHAMBER FOR A SMALL LABORATORY WITH SMALL BUDGET

DISCLAIMER OF QUALITY

EXPERT SYSTEMS IN ULTRASONIC FLOW METERS

Instruction and Maintenance Manual

In addition to reading this assignment, also read Appendices A and B.

Testing the Vented, 7-Liter Induction Chamber. Report 6 April 2008

Influence of Persons' Movements on Ventilation Effectiveness Brohus, Henrik; Hyldig, Mikkel; Kamper, Simon; Vachek, Ulla Maria

University of North Florida Performance Requirements For Laboratory Fume Hoods. As Manufactured Performance Tests. As Installed Performance Tests

Evaluation of Commercially Available Techniques and Development of Simplified Methods for Measuring Grille Airflows in HVAC Systems

OPTIMIZING THE LENGTH OF AIR SUPPLY DUCT IN CROSS CONNECTIONS OF GOTTHARD BASE TUNNEL. Rehan Yousaf 1, Oliver Scherer 1

Results and Discussion for Steady Measurements

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

INSTRUCTION MANUAL. Microphone Type 4966 for Hand held Analyzer Types 2250, 2250 L and Supplement to Instruction Manual BE 1712

Application Note AN-107

SEMEM3-78 Testing and calibrating instrumentation and control equipment and circuits

7 th International Conference on Wind Turbine Noise Rotterdam 2 nd to 5 th May 2017

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

CONSIDERATION OF DENSITY VARIATIONS IN THE DESIGN OF A VENTILATION SYSTEM FOR ROAD TUNNELS

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK

vento specification sheet

Detecting points of unintentional ventilation

Walk - Run Activity --An S and P Wave Travel Time Simulation ( S minus P Earthquake Location Method)

Instruction Manual. Pipe Friction Training Panel

Ideal gas law. Introduction

Agilent Dimension Software for ELSD User Manual

deltaflowc deltaflowc Venturi or Probe

Instruction and Maintenance Manual

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

AIR DIFFUSION INDUCTIVE MICRO-PERFORATED DUCTS

HYDROGEN - METHANE MIXTURES : DISPERSION AND STRATIFICATION STUDIES

for Pleasant & Healthy Air-Distribution ISO 9001:2000 Linear Slot Diffusers Product Bulletin 133-D

Pressure Losses in 12, 14, and 16 Non-Metallic Flexible Ducts with Compression and Sag

HAP e-help. Obtaining Consistent Results Using HAP and the ASHRAE 62MZ Ventilation Rate Procedure Spreadsheet. Introduction

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Occupant body movement and seat occupancy rate for design of desk microenvironment

Flow in a shock tube

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

Evaluation of the optimum conditions for a local ventilation system in connection with the mine ventilation network

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Elimination of Oil Residual inside the Copper Pipe Using Ladder Technique

Advanced Test Equipment Rentals ATEC (2832)

bespoke In general health and rehabilitation Breath-by-breath multi-functional respiratory gas analyser In human performance

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Uncertainties in Environmental Noise Assessments ISO 1996, Effects of Instrument Class and Residual Sound

Draft. Equipment/Instrument

Smart Water Application Technologies (SWAT)

Transcription:

Table of contents A1 Design criteria 1 A1.1 Local thermal discomfort indices........................... 1 A2 Experiment set-up 3 A2.1 Equipment....................................... 3 A2.2 Test cases....................................... 5 A3 Experiment results 11 A3.1 Airflow distribution.................................. 11 A3.2 Tracer gas concentration measurements for Case 13................. 21 A3.3 Pressure drop..................................... 22 A4 CFD Results 27 I Drawings 33 Bibliography 37 I

Appendix A1 Design criteria A1.1 Local thermal discomfort indices In DS/EN ISO 7730 [2006] can be found equations for Percentage Dissatisfied caused by vertical air temperature difference (PD VTG ), see (A1.1), and caused by radiant assymetry related to cool ceiling (PD RA ), see (A1.2). PD V T G = 100 1 + exp(5.76 0.856 t a,v ) for t a,v < 8 C (A1.1) PD V T G Percentage Dissatisfied due to vertical temperature gradient [%] t a,v Vertical air temperature assymetry between head and feet [ C] PD RA = 100 1 + exp(9.93 0.50 t pr ) for t pr < 15 C (A1.2) PD RA Percentage Dissatisfied due to temperature assymetry related to cool ceiling [%] t pr Radiant temperature assymetry [ C] 1

Appendix A2 Experiment set-up A2.1 Equipment This section consider equipment used for measuring velocity, temperature, concentration and power for heat gains. Logging equipment, sensors and theirs precision are given. Measuring points are described in main report in section 4.2. Velocity is measured in 15 points on five movable columns using Dantec 54R10 hot-sphere anemometers, see figure 4.8(b) in main report. The accuracy of the sensors can be estimated to ±5% of reading, see Cena and de Dear [1998], but also depends on the accuracy of calibration. According to Stannov et al. [1998] and DS/EN ISO 7726 [2001] required accuracy of mean air velocity measurments is equal to ±0.05 m / s, so used velocity sensors fulfill accuracy requirements. These anemometers are low velocity transducers and are connected to two dataloggers, which are next connected to laptop with a control software, see figure A2.1. Figure A2.1: Set-up of equipment measuring velocity. Temperature is measured by thermocouples. Two kind of type K thermocouples are used, which are thick and thin. The main difference is size of the sensor and their time constant. Thin thermocouple can be seen on figure 4.12(a) in main report and thick thermocouples is presented on figure A2.2(a). Thin thermocouples are used to measure surface temperature and temperature gradient below the ceiling and the rest of thermocouples are thick. According to DS/EN ISO 7726 [2001] required accuracy of air and surface temperature measurements is ±0.5 C and desired is equal to ±0.2 C. 3

Appendix A2 - Experiment set-up For sensors the uncertainty can be estimated to be equal to 0.08 K for thick thermocouples and 0.09 K for thin thermocouples, see Artmann et al. [2008], so used thermocouples fulfill both required and desired accuracy. The thermocouples are connected to compensation boxes and next to Helios Fluke Datalogger, which is linked to a personal computer that saves the results. Temperature in each of two compensation boxes is measured by two thick thermocouples, which are connected to Ice Point Reference. Data from Ice Point Reference is also logged by Helios Fluke Datalogger. The set-up for thermocouples can be seen on figure A2.2(b). (a) Figure A2.2: Pictures of a) thick thermocouple sensor, b) set-up for equipment measuring temperature. (b) Concentration is measured by Innova 1412 Photoacoustic Field Gas-Monitor connected to Multipoint Sampler and Doser INNOVA 1303. It is possible to measure concentration at six points at the same time, when the Multipoint Sampler and Doser is used. This equipment, see figure A2.3(a), is used to observe concentration of tracer gas, N 2 O, in the chosen sampling points. Sampler and Doser collect samples and one by one transfer them to Gas-Monitor. Sensitive microphone measures radiation level in measuring chamber and using calibration factors concentration of N 2 O in the sample can be calculated. Detection level for nitrous oxide is equal to 0.05 ppm. The last large set of equipment is used to measure power supplied to mannequins, radiators, light bulbs or heating wires. Three variable AC power supplies are used. Each of them is connected to wattmeter. The set-up is presented on figure A2.3(b). Power supplied to the room is monitored, but it can variate due to changes of voltage in power grid. Error is estimated to ±2% of the reading. 4

Appendix A2 - Experiment set-up (a) Figure A2.3: Picture of a) set-up of equipment measuring velocity and concentration, b) variable AC power supply with watt meter to measure power supplied to heat gains. (b) A2.2 Test cases In this section detailed drawings of heat sources locations for different cases will be presented. For all the cases drawings presenting plane view will be given, cross-section showing heights of the heat sources will be presented only for Case 5, with mannequines densely located in one part of the room and light bulbs. For other cases the heights of the heat sources are equal to the mentioned one. It should be noted that heating wires are not presented on the cross-section, as they are located on the floor. Legend with symbols of the heat sources used on drawings in this section is presented in table A2.1. Symbol Description Light bulb Mannequin Radiator Heating wires Table A2.1: Legend of symbols of the heat sources. 5

Appendix A2 - Experiment set-up Mannequins equally distributed in the room Cases: 1, 2, 3 Figure A2.4: Plane view of the room with heat sources location for the cases with mannequins equally distributed in the room. 6

Appendix A2 - Experiment set-up Mannequins and radiators on one side the room Case: 4 Figure A2.5: Plane view of the room for the case with heat sources located on one side of the room. Mannequins densely located in one part of the room and light bulbs Case: 5 (a) Figure A2.6: Drawings for the case with mannequins densely located in one part of the room and light bulbs a) plan view, b) cross-section. (b) 7

Appendix A2 - Experiment set-up Radiator in the corner Case: 6 Figure A2.7: Plane view of the room with radiator located in the corner. Radiator in the middle Case: 7 Figure A2.8: Plane view of the room with radiator located in the middle of the room. 8

Appendix A2 - Experiment set-up Heating wires and light bulbs Cases: 8, 9, 10 Figure A2.9: Plane view of the room with heating wires and light bulbs. 9

Appendix A3 Experiment results A3.1 Airflow distribution A3.1.1 Velocity distribution In this part mean velocity results, which are not presented in the main report are introduced. Cases with unequally distributed heat sources 1 2 3 4 5 A B C D E 1.7 m 0.16 X X 0.17 0.19 1.1 m 0.13 0.17 0.16 0.15 0.17 0.1 m 0.09 0.12 0.16 0.13 0.13 1.7 m 0.13 X X 0.13 0.28 1.1 m 0.11 0.25 0.13 0.10 0.20 0.1 m 0.11 0.15 0.15 0.07 0.14 1.7 m 0.08 X X 0.10 0.07 1.1 m 0.09 0.08 0.06 0.11 0.07 0.1 m 0.12 0.18 0.12 0.10 0.18 1.7 m 0.07 X X 0.10 0.09 1.1 m 0.08 0.08 0.13 0.11 0.13 0.1 m 0.17 0.23 0.28 0.17 0.24 1.7 m 0.09 X X 0.11 0.23 1.1 m 0.11 0.20 0.21 0.11 0.20 0.1 m 0.20 0.22 0.19 0.18 0.19 1 2 3 4 5 A B C D E 1.7 m 0.13 X X 0.11 0.18 1.1 m 0.10 0.15 0.14 0.10 0.14 0.1 m 0.08 0.11 0.11 0.07 0.07 1.7 m 0.10 X X 0.10 0.21 1.1 m 0.08 0.19 0.10 0.09 0.14 0.1 m 0.06 0.11 0.13 0.05 0.10 1.7 m 0.08 X X 0.08 0.06 1.1 m 0.08 0.07 0.05 0.10 0.06 0.1 m 0.12 0.13 0.09 0.07 0.10 1.7 m 0.06 X X 0.08 0.07 1.1 m 0.10 0.10 0.11 0.11 0.10 0.1 m 0.19 0.27 0.23 0.20 0.22 1.7 m 0.08 X X 0.07 0.15 1.1 m 0.09 0.17 0.21 0.06 0.13 0.1 m 0.15 0.18 0.16 0.15 0.18 (a) Figure A3.1: Velocity distribution in the room for a) Test 4a, b) Test 4c. (b) 11

Appendix A3 - Experiment results 1 2 3 4 5 A B C D E 1.7 m 0.07 x x 0.17 0.06 1.1 m 0.07 0.14 0.18 0.16 0.07 0.1 m 0.16 0.15 0.11 0.14 0.16 1.7 m 0.07 x x 0.06 0.09 1.1 m 0.11 0.09 0.05 0.05 0.10 0.1 m 0.18 0.19 0.19 0.17 0.17 1.7 m 0.07 x x 0.04 0.07 1.1 m 0.10 0.07 0.06 0.06 0.09 0.1 m 0.14 0.18 0.09 0.16 0.17 1.7 m 0.10 x x 0.06 0.06 1.1 m 0.11 0.12 0.06 0.05 0.07 0.1 m 0.09 0.12 0.11 0.04 0.04 1.7 m 0.10 x x 0.07 0.20 1.1 m 0.09 0.11 0.08 0.08 0.08 0.1 m 0.09 0.06 0.06 0.04 0.04 1 2 3 4 5 A B C D E 1.7 m 0.07 x x 0.11 0.05 1.1 m 0.07 0.14 0.15 0.11 0.08 0.1 m 0.16 0.15 0.14 0.15 0.15 1.7 m 0.07 x x 0.04 0.05 1.1 m 0.10 0.07 0.06 0.06 0.09 0.1 m 0.21 0.19 0.20 0.16 0.18 1.7 m 0.06 x x 0.05 0.05 1.1 m 0.08 0.06 0.07 0.05 0.08 0.1 m 0.07 0.08 0.08 0.05 0.05 1.7 m 0.11 x x 0.04 0.07 1.1 m 0.11 0.13 0.05 0.05 0.07 0.1 m 0.17 0.16 0.09 0.04 0.03 1.7 m 0.11 x x 0.07 0.18 1.1 m 0.11 0.12 0.08 0.08 0.08 0.1 m 0.12 0.06 0.05 0.04 0.03 (a) Figure A3.2: Velocity distribution in the room for a) Test 5a, b) Test 5b. (b) 12

Appendix A3 - Experiment results Cases with heating wires and light bulbs 1 2 3 4 5 A B C D E 1.7 m 0.19 X X 0.18 0.22 1.1 m 0.21 0.21 0.21 0.18 0.20 0.1 m 0.18 0.20 0.20 0.15 0.15 1.7 m 0.14 X X 0.16 0.11 1.1 m 0.16 0.14 0.13 0.17 0.14 0.1 m 0.28 0.31 0.29 0.25 0.24 1.7 m 0.12 X X 0.13 0.09 1.1 m 0.16 0.12 0.10 0.15 0.13 0.1 m 0.28 0.16 0.17 0.27 0.25 1.7 m 0.14 X X 0.12 0.09 1.1 m 0.19 0.12 0.10 0.12 0.09 0.1 m 0.29 0.17 0.14 0.14 0.12 1.7 m 0.16 X X 0.18 0.19 1.1 m 0.19 0.18 0.17 0.20 0.16 0.1 m 0.13 0.12 0.15 0.13 0.10 (a) 1 2 3 4 5 A B C D E 1.7 m X X X X X 1.1 m X X X X X 0.1 m X X X X X 1.7 m 0.12 X X 0.13 0.10 1.1 m 0.13 0.14 0.14 0.14 0.13 0.1 m 0.21 0.28 0.26 0.23 0.23 1.7 m X X X X X 1.1 m X X X X X 0.1 m X X X X X 1.7 m X X X X X 1.1 m X X X X X 0.1 m X X X X X 1.7 m X X X X X 1.1 m X X X X X 0.1 m X X X X X (b) 1 2 3 4 5 A B C D E 1.7 m X X X X X 1.1 m X X X X X 0.1 m X X X X X 1.7 m 0.11 X X 0.10 0.11 1.1 m 0.13 0.14 0.14 0.13 0.13 0.1 m 0.21 0.26 0.25 0.21 0.22 1.7 m 0.12 X X 0.13 0.10 1.1 m 0.12 X 0.13 0.16 0.14 0.1 m 0.14 X 0.15 0.23 0.22 1.7 m 0.06 X X X X 1.1 m 0.16 X X X X 0.1 m 0.20 X X X X 1.7 m X X X X X 1.1 m X X X X X 0.1 m X X X X X (c) Figure A3.3: Velocity distribution in the room for a) Test 8a b), Test 8b, c) Test 8c. 13

Appendix A3 - Experiment results 1 2 3 4 5 A B C D E 1.7 m 0.13 X X 0.14 0.16 1.1 m 0.14 0.16 0.17 0.13 0.15 0.1 m 0.14 0.14 0.14 0.13 0.12 1.7 m 0.10 X X 0.14 0.11 1.1 m 0.12 0.12 0.11 0.14 0.12 0.1 m 0.18 0.22 0.22 0.17 0.17 1.7 m 0.09 X X 0.10 0.06 1.1 m 0.10 0.10 0.10 0.12 0.10 0.1 m 0.17 0.22 0.23 0.19 0.20 1.7 m 0.10 X X 0.10 0.08 1.1 m 0.11 0.09 0.08 0.12 0.09 0.1 m 0.16 0.20 0.21 0.18 0.18 1.7 m 0.15 X X 0.15 0.16 1.1 m 0.13 0.15 0.15 0.13 0.14 0.1 m 0.09 0.06 0.10 0.09 0.07 1 2 3 4 5 A B C D E 1.7 m 0.14 X X 0.14 0.17 1.1 m 0.15 0.16 0.17 0.14 0.15 0.1 m 0.14 0.15 0.16 0.12 0.13 1.7 m 0.12 X X 0.13 0.10 1.1 m 0.13 0.13 0.12 0.14 0.12 0.1 m 0.17 0.23 0.23 0.17 0.18 1.7 m 0.11 X X 0.11 0.07 1.1 m 0.12 0.11 0.11 0.13 0.11 0.1 m 0.17 0.23 0.25 0.21 0.19 1.7 m 0.10 X X 0.10 0.09 1.1 m 0.12 0.10 0.09 0.12 0.09 0.1 m 0.16 0.20 0.22 0.20 0.17 1.7 m 0.14 X X 0.15 0.16 1.1 m 0.14 0.15 0.15 0.14 0.14 0.1 m 0.08 0.07 0.11 0.09 0.08 (a) Figure A3.4: Velocity distribution in the room for a) Test 9a, b) Test 9b. (b) 1 2 3 4 5 A B C D E 1.7 m 0.12 X X 0.13 0.16 1.1 m 0.13 0.17 0.16 0.12 0.15 0.1 m 0.14 0.15 0.15 0.12 0.12 1.7 m 0.11 X X 0.11 0.10 1.1 m 0.12 0.13 0.12 0.13 0.13 0.1 m 0.16 0.21 0.21 0.17 0.18 1.7 m 0.11 X X 0.10 0.07 1.1 m 0.12 0.11 0.11 0.11 0.10 0.1 m 0.17 0.22 0.24 0.18 0.19 1.7 m 0.12 X X 0.11 0.10 1.1 m 0.12 0.10 0.10 0.12 0.10 0.1 m 0.15 0.19 0.22 0.16 0.18 1.7 m 0.14 X X 0.15 0.17 1.1 m 0.14 0.14 0.15 0.14 0.14 0.1 m 0.07 0.07 0.10 0.08 0.07 1 2 3 4 5 A B C D E 1.7 m 0.11 X X 0.12 0.14 1.1 m 0.11 0.14 0.13 0.10 0.12 0.1 m 0.14 0.14 0.15 0.12 0.12 1.7 m 0.09 X X 0.09 0.08 1.1 m 0.12 0.13 0.12 0.11 0.11 0.1 m 0.16 0.20 0.19 0.15 0.17 1.7 m 0.12 X X 0.10 0.08 1.1 m 0.13 0.13 0.13 0.11 0.11 0.1 m 0.15 0.19 0.20 0.16 0.17 1.7 m 0.11 X X 0.10 0.08 1.1 m 0.11 0.10 0.10 0.11 0.10 0.1 m 0.09 0.10 0.12 0.14 0.16 1.7 m 0.14 X X 0.13 0.15 1.1 m 0.14 0.14 0.14 0.13 0.13 0.1 m 0.08 0.09 0.11 0.09 0.08 (a) Figure A3.5: Velocity distribution in the room for a) Test 9c, b) Test 9d. (b) 14

Appendix A3 - Experiment results 1 2 3 4 5 A B C D E 1.7 m 0.08 X X 0.07 0.10 1.1 m 0.09 0.11 0.12 0.07 0.10 0.1 m 0.10 0.10 0.10 0.09 0.07 1.7 m 0.09 X X 0.09 0.07 1.1 m 0.09 0.07 0.08 0.10 0.08 0.1 m 0.14 0.15 0.14 0.13 0.12 1.7 m 0.05 X X 0.08 0.04 1.1 m 0.07 0.04 0.05 0.09 0.04 0.1 m 0.14 0.10 0.17 0.14 0.13 1.7 m 0.07 X X 0.07 0.05 1.1 m 0.08 0.06 0.06 0.07 0.05 0.1 m 0.10 0.08 0.09 0.07 0.05 1.7 m 0.10 X X 0.12 0.12 1.1 m 0.09 0.11 0.11 0.12 0.10 0.1 m 0.07 0.04 0.05 0.07 0.03 1 2 3 4 5 A B C D E 1.7 m 0.05 X X 0.06 0.11 1.1 m 0.07 0.08 0.10 0.06 0.09 0.1 m 0.11 0.10 0.08 0.08 0.07 1.7 m 0.06 X X 0.07 0.06 1.1 m 0.09 0.07 0.07 0.09 0.07 0.1 m 0.13 0.13 0.13 0.12 0.10 1.7 m 0.07 X X 0.06 0.04 1.1 m 0.09 0.06 0.06 0.10 0.06 0.1 m 0.12 0.13 0.14 0.13 0.11 1.7 m 0.07 X X 0.07 0.05 1.1 m 0.09 0.07 0.06 0.10 0.06 0.1 m 0.10 0.11 0.12 0.11 0.10 1.7 m 0.10 X X 0.11 0.11 1.1 m 0.10 0.10 0.10 0.11 0.09 0.1 m 0.07 0.04 0.04 0.06 0.02 (a) Figure A3.6: Velocity distribution in the room for a) Test 10a, b) Test 10b. (b) 1 2 3 4 5 A B C D E 1.7 m 0.05 x x 0.02 0.03 1.1 m 0.04 0.02 0.05 0.02 0.02 0.1 m 0.06 0.07 0.04 0.06 0.06 1.7 m 0.04 x x 0.03 0.04 1.1 m 0.04 0.03 0.03 0.03 0.04 0.1 m 0.06 0.06 0.07 0.06 0.05 1.7 m 0.06 x x 0.06 0.07 1.1 m 0.06 0.05 0.03 0.06 0.06 0.1 m 0.04 0.04 0.05 0.04 0.03 1.7 m 0.06 x x 0.04 0.07 1.1 m 0.07 0.05 0.03 0.03 0.05 0.1 m 0.03 0.04 0.05 0.04 0.04 1.7 m 0.07 x x 0.04 0.04 1.1 m 0.06 0.05 0.04 0.04 0.04 0.1 m 0.04 0.03 0.04 0.03 0.03 Figure A3.7: Velocity distribution in the room for Case 13. 15

Appendix A3 - Experiment results Case with equally distributed heat sources 1 2 3 4 5 A B C D E 1.7 m 0.13 X X 0.11 0.13 1.1 m 0.13 0.13 0.10 0.11 0.11 0.1 m 0.08 0.15 0.13 0.09 0.10 1.7 m 0.16 X X 0.11 0.10 1.1 m 0.15 0.11 0.09 0.11 0.09 0.1 m 0.11 0.18 0.16 0.07 0.11 1.7 m 0.14 X X 0.12 0.10 1.1 m 0.14 0.15 0.10 0.12 0.10 0.1 m 0.11 0.19 0.18 0.08 0.12 1.7 m 0.14 X X 0.11 0.10 1.1 m 0.14 0.11 0.07 0.11 0.10 0.1 m 0.13 0.20 0.18 0.08 0.13 1.7 m 0.19 X X 0.10 0.11 1.1 m 0.20 0.14 0.10 0.10 0.09 0.1 m 0.10 0.19 0.17 0.09 0.12 (a) 1 2 3 4 5 A B C D E 1.7 m 0.11 X X 0.08 0.10 1.1 m 0.10 0.10 0.09 0.06 0.09 0.1 m 0.09 0.12 0.10 0.08 0.07 1.7 m 0.08 X X 0.09 0.09 1.1 m 0.08 0.09 0.09 0.09 0.08 0.1 m 0.06 0.10 0.11 0.09 0.12 1.7 m 0.09 X X 0.07 0.09 1.1 m 0.09 0.13 0.09 0.08 0.08 0.1 m 0.09 0.12 0.12 0.07 0.07 1.7 m 0.12 X X 0.07 0.09 1.1 m 0.11 0.10 0.07 0.08 0.07 0.1 m 0.11 0.17 0.15 0.06 0.09 1.7 m 0.13 X X 0.08 0.09 1.1 m 0.13 0.09 0.06 0.07 0.08 0.1 m 0.09 0.14 0.13 0.06 0.07 (b) 1 2 3 4 5 A B C D E 1.7 m 0.08 X X 0.07 0.11 1.1 m 0.09 0.10 0.09 0.06 0.09 0.1 m 0.08 0.11 0.09 0.08 0.09 1.7 m 0.09 X X 0.07 0.09 1.1 m 0.09 0.09 0.08 0.07 0.08 0.1 m 0.10 0.13 0.11 0.06 0.07 1.7 m 0.08 X X 0.08 0.09 1.1 m 0.08 0.11 0.08 0.08 0.09 0.1 m 0.06 0.07 0.08 0.07 0.07 1.7 m 0.10 X X 0.07 0.09 1.1 m 0.09 0.09 0.06 0.07 0.07 0.1 m 0.13 0.16 0.14 0.05 0.08 1.7 m 0.12 X X 0.06 0.09 1.1 m 0.12 0.10 0.07 0.05 0.07 0.1 m 0.10 0.13 0.11 0.06 0.07 (c) Figure A3.8: Velocity distribution in the room for a) Test 1a b), Test 1e, c) Test 1f. 16

Appendix A3 - Experiment results Cases with different supply areas 1 2 3 4 5 A B C D E 1.7 m 0.07 X X 0.09 0.07 1.1 m 0.07 0.08 0.07 0.08 0.06 0.1 m 0.09 0.08 0.08 0.09 0.09 1.7 m 0.09 X X 0.08 0.07 1.1 m 0.08 0.09 0.07 0.09 0.06 0.1 m 0.09 0.12 0.10 0.06 0.05 1.7 m 0.08 X X 0.09 0.08 1.1 m 0.09 0.12 0.08 0.10 0.07 0.1 m 0.05 0.06 0.06 0.06 0.06 1.7 m 0.08 X X 0.07 0.07 1.1 m 0.07 0.08 0.06 0.07 0.06 0.1 m 0.12 0.14 0.11 0.08 0.05 1.7 m 0.11 X X 0.07 0.06 1.1 m 0.12 0.09 0.06 0.07 0.05 0.1 m 0.12 0.14 0.11 0.08 0.06 Figure A3.9: Velocity distribution in the room for Test 2a. A3.1.2 Stability problem In this part detailed velocity results with an interval of 0.1 s, which are not presented in the main report are given. Velocity graphs are made for only one measuring point where the maximum mean velocity in the room is measured. 17

Appendix A3 - Experiment results 0.6 0.5 0.4 0.3 0.2 0.1 0 0 200 400 600 800 1000 Time [s] Test 1a Mean Figure A3.10: Velocity results for Test 1a with 0.1 s interval. 0.6 0.5 0.4 0.3 0.2 0.1 0 0 200 400 600 800 1000 Time [s] Test 1c Mean Figure A3.11: Velocity results for Test 1c with 0.1 s interval. 18

Appendix A3 - Experiment results 0.6 0.5 0.4 0.3 0.2 0.1 0 0 200 400 600 800 1000 Time [s] Test 1e Mean Figure A3.12: Velocity results for Test 1e with 0.1 s interval. 0.6 0.5 0.4 0.3 0.2 0.1 0 0 200 400 600 800 1000 Time [s] Test 1f Mean Figure A3.13: Velocity results for Test 1f with 0.1 s interval. 19

Appendix A3 - Experiment results 0.6 0.5 0.4 0.3 0.2 0.1 0 0 200 400 600 800 1000 Time [s] Test 6 Mean Figure A3.14: Velocity results for Test 6 with 0.1 s interval. 0.6 0.5 0.4 0.3 0.2 0.1 0 0 200 400 600 800 1000 Time [s] Test 7 Mean Figure A3.15: Velocity results for Test 7 with 0.1 s interval. 20

Appendix A3 - Experiment results 0.6 0.5 0.4 0.3 0.2 0.1 0 0 200 400 600 800 1000 Time [s] Test 11 Mean Figure A3.16: Velocity results for Test 11 with 0.1 s interval. A3.2 Tracer gas concentration measurements for Case 13 In this section tracer gas concentration results are presented, which are results of measurements performed for Case 13. Legend for the points is presented in table A3.1 and results are shown on figure A3.17. Point Location 1 Bottle 2 Chamber 3 3 Chamber 1 4 Extract duct 5 Middle column 1.7 m 6 Middle column 4.3 m Table A3.1: Legend for the points used on graph with tracer gas results (points numbers are shown on the graph under letter C). 21

Appendix A3 - Experiment results Figure A3.17: Graph presenting tracer gas concentration results. A3.3 Pressure drop Pressure drop described in Yang [2011] shows that the solution with 7 mm hole used to supply air to the room can be characterised by low resistance for air flow. The results are presented on figure A3.18(a). It is possible that low pressure drop is connected with airflow thought slots and cracks between acoustic panels, which can also be seen for diffuse ceiling presented in Jakubowska [2009]. The results can be compared with other solutions available on the market. One of the solutions can be a diffuser distributed by Lindab company. When for instance airflow equal to 100 l / s is considered pressure drop for the ceiling is equal to 3 Pa, see A3.18(a), when for Lindab s ø125 diffuser it is around 52 Pa, see A3.18(b). However, when noise requirements are taken into consideration, for instance 35 db(a) for classroom in category B building from CR 1752 [1998], pressure drop can be lowered for ø200 diffuser to 12 Pa. 22

Appendix A3 - Experiment results Pressure drop [Pa] 4.0 4 3.5 3,5 3.0 3 2.5 2,5 2.0 2 1.5 1,5 1.0 1 Pressure drop - Flow rate Linear (Pressure drop - Flow rate) y = 0,0378x - 0,6177 R² = 0,9934 0.5 0,5 0,0 0 20,0 40,0 60,0 80,0 100,0 120,0 Flow rate [l/s] (a) Figure A3.18: Pressure drop a) as a function of a volume flow rate for diffuse ceiling inlet, b) as a function of a volume flow rate and A-weighted sound power level of diffuser from Lindab company. Figures edited from Yang [2011] (b) Diffuse ceiling described in Jacobs and Knoll [2009] is made from panels with 25 mm holes. Decentralised system with DCV is compared with traditional and modern systems for schools in Netherlands. It is presented that, when low pressure drop construction for ceiling is used and the size of system is small, due to decentralised location, Specific Fan Power, SPF, and as an effect power consumption of the system can be significantly decreased, see table A3.2. However low pressure drop, energy use and noise level for presented solutions can be only archived for low airflow, see table A3.3. This airflow, when standard CR 1752 [1998] for classroom for category B building is considered, can be enough for 21 person in classroom. For more pupils in classroom airflow can increase and change the presented parameters. It should be noted that medium and high airflows do not fulfill maximum sound pressure in the room. Ventilation system SPF [ kw / m 3] Traditional 5-10 Modern 2-2.5 Primary school Sliedrecht 0.04 Primary school Tilburg 0.5 Table A3.2: Comparison of specific fan power, SPF, for different ventilation systems. [Jacobs and Knoll 2009] 23

Appendix A3 - Experiment results Airflow L p Pressure drop Energy use [ ] [ m3 / s ] [db(a)] [Pa] [W] Low 0.18 28 6 8 Medium 0.39 41 60 50 High 0.61 53 144 172 Table A3.3: Performance of decentralised supply and return ventilation system. [Jacobs and Knoll 2009] In addition to pressure drop measurements, tracer gas test is conducted to check the performance and tightness of ceiling s construction. In this experiment set-up the only chamber working as an inlet is Chamber 1 and this chamber is used to distribute tracer gas in the room, while tracer gas concentration is measured in two other chambers, Chambers 2 and 3, which are closed. It can be seen on figure A3.17 that concentrations in Chambers 2 and 3 are constant after a period of time and that concentrations in the chambers increase in a fast manner. This could implicate that there is a fresh air coming to the chambers or an air leakage in the system. It is decided to test this problem. The location of sampling tubes for this set-up is shown in table A3.4. Point Location 1 Bottle 2 Chamber 2 3 Chamber 3 4 Extract duct 5 Middle column 1.7 m 6 Middle column 4.3 m Table A3.4: Legend for the points used on graph tracer gas results presented below. Points numbers are shown on the graph under letter C. 24

Appendix A3 - Experiment results Figure A3.19: Graph presenting tracer gas concentration results carried out to check the performance of the ceiling s construction. 25

Appendix A4 CFD Results In this chapter the rest of CFD results is presented. High room s model results can be seen on figures A4.1, A4.2, A4.3, A4.4. Low room s model results can be seen on figures A4.5, A4.6, A4.7, A4.8. (a) Figure A4.1: High room s model results on a Short cross-section for a) temperature, b) velocity (b) 27

Appendix A4 - CFD Results (a) Figure A4.2: High room s model results on a 0.1 m plane cut for a) temperature, b) velocity (b) (a) Figure A4.3: High room s model results on a 1.1 m plane cut for a) temperature, b) velocity (b) 28

Appendix A4 - CFD Results (a) Figure A4.4: High room s model results on a 1.7 m plane cut for a) temperature, b) velocity (b) (a) Figure A4.5: Low room s model results on a Short cross-section for a) temperature, b) velocity (b) 29

Appendix A4 - CFD Results (a) Figure A4.6: Low room s model results on a 0.1 m plane cut for a) temperature, b) velocity (b) (a) Figure A4.7: Low room s model results on a 1.1 m plane cut for a) temperature, b) velocity (b) 30

Appendix A4 - CFD Results (a) Figure A4.8: Low room s model results on a 1.7 m plane cut for a) temperature, b) velocity (b) 31

Part I Drawings 33

Bibliography Artmann, Vonbank, and Jensen, 2008. N. Artmann, R. Vonbank, and R. L. Jensen. Temperature measurements using type K thermocouples and the Fluke Helios Plus 2287A data logger. Aalborg University, 2008. Cena and Dear, 1998. Krzysztof Cena and Richard de Dear. Field study of occupant comfort and office thermal environments in a hot-arid climate. ISBN: 0-86905-648-4, ASHRAE Report. Murdoch University, 1998. CR 1752, 1998. CR 1752. Ventilation for buildings - Design criteria for the indoor environment, 1998. DS/EN ISO 7726, 2001. DS/EN ISO 7726. Ergonomics of the thermal environment - Instruments for measuring physical quantities, 2001. DS/EN ISO 7730, 2006. DS/EN ISO 7730. Ergonomics of the thermal environment-analitycal determination and interpretation of thermal comfort using calculation of the PMV and PPD indicies and local thermal comfort criteria, 2006. Jacobs and Knoll, 2009. Piet Jacobs and Bas Knoll. Diffuse Ceiling ventilation for fresh classrooms. 4th Intern. Symposium on Building and Ductwork Air tightness and 30th AIVC Conference Trends in High Performance Buildings..., October 1-2, Berlin, Germany, 2009. Jakubowska, 2009. Ewa Jakubowska. Air Distribution in Rooms with Diffuse Ceiling Inlet. COLD CLIMATE HVAC 2009 : Sisimiut Greenland, 16-19 March 2009, 2009. Stannov, Melikov, Popiolek, and Jørgensen, 1998. T. Stannov, A.K. Melikov, Z. Popiolek, and F.E. Jørgensen. Test method for describing directional sensitivity of anemometers for low velocity measurements indoors. ASHRAE Transactions, Vol. 104, p. 1481 1489, 1998. Yang, 2011. Honglu Yang. Experimental and Numerical Analysis of Diffuse Ceiling Ventilation. Master Thesis, Technical University of Denmark, 2011. 37