1 Heating Ventilation Air Conditioning (HVAC) Technical Platform Recommended specialist equipment including instruments for those working with Healthcare Ventilation Systems Those working with Healthcare Ventilation Systems should have access to and use appropriate specialist equipment including instruments (and have appropriate training and knowledge to use and operate safely), the following is a list of equipment: This table is applicable to, project managers, designers, installers, commissioners, validators, operators, maintainers, verifiers, infection prevention and other with an interest in Healthcare Ventilation and is in addition to the normal engineering tools, equipment and instruments. Tachometer suitable for measuring fan and motor speeds Pitot-static tube for the measurement of velocity within ducts Bal-o-meter (or hood) Swirl air flow conditioner Stand for Bal-o-meter Rotary vane anemometer Testing correct direction and speed of rotation e.g. Fans Traversing duct work for main, branch and volumes Note suitable for measurements above 3m/s (BSRIA BG49). Measurement volumes needs to have a correction factor for each type and size of. Also, used to aid calculation of air change rates. Measurement of swirl diffusers, correction factors required With Bal-o-meter, for safe working, more accurate results. Only for use on grilles, limited accuracy, needs to have a correction factor applied
2 (not suitable for diffusers) Hot-wire/thermal anemometer Specialist dust-lamp (Tyndall beam) Sound meter, class to suit use, incl acoustic calibrator Wound site velocities conventional theatre, clean room, Ultra Clean Canopy velocities, Traverse measurements below and above 3m/s Visualising particle streams Measuring sound levels in rooms and ventilation systems. Photometer Aerosol Generator Particle counter Active air sampler DOP tests for HEPA filters in ultra clean canopies, Sterile services and aseptic suites, Entrainment testing of Ultra Clean Canopies, Generator of, DOP for testing HEPA filters in ultra clean canopies, Sterile services and aseptic suites, Entrainment testing of Ultra Clean Canopies Clean room classification of Sterile services and aseptic suites Microbiological air sampling. Pro air sampler Monitoring and sampling in small confined spaces. Fan Belt tension tester Pulley alignment tester Fan Belt Gauge Testing fan belt tension pulley alignment drive belt
3 Pulley (Sheave) Gauge Micromanometer also for use when testing filter gauges and pressure switches, duct static pressures, room pressures Thermometer with humidity sensor CO2 Monitor Temperature thermocouple for use with say thermometer or anemometer Duct and dust measurement equipment/instruments as defined in BESA TR/19 (DTT/PVT) (dust thickness measurement instruments either comb or electronic or vacuum instruments as defined in BESA TR/19 for example in appendix E Digital camera Volt meter Ammeter Proving unit (electrical) Draft or worn pulley Measuring differential pressures for hierarchy of cleanliness air paths / pressure cascades and open/closed door protection. Used with Pitot tube to traverse duct work for main, branch and volumes. Also, system static pressures, component pressure drops, fan pressure. Environmental conditions inside and out, as well as temperature changes in vent system components Monitoring and surveying CO2. Temperature changes on energy recovery devices and other ventilation components Testing amount of dust on ducts or ventilation plant. Photographic evidence on the condition of parts of ventilation system e.g. fire dampers, water ponding etc Checking control function. Checking control function. Electrical safety isolation, testing for dead. Water manometer incl electronic, pressure rating to suit use Caution signs and marked padlocks (with single key) Manometer for measuring flow rates and component pressure drops. To communicate to others persons working on system, essential part of safe system of work
4 Lock out tag out system As above Laser Measure Calculation of room sizes e.g. for air change rates. Denotes recommendation Copies of test and/or calibration certificates shall be available and calibrated at values the equipment could be used, recommended maximum calibration period 1 year, if damaged the equipment should be repaired and recalibrated before next use. The list is recommended for use by all those commissioning, validating, verifying or operating healthcare ventilation systems, in short anyone involved in the delivery or use of healthcare ventilation systems. The lists above are not intended to be complete or exhaustive, so please do let the committee know of any that you think should be added or removed. There is no objection to the free reproduction of this Page, providing is source and author Richard Knight CEng., MCIBSE, FIHEEM and Dave Williams MIHEE, MIET
5
CTG Certification Protocol -- Version 3.0 SUMMARY
Date of Test: Test Report Number: SUMMARY Date of Prior Certification: Certified by: Re-certification Due Date: Unit Description: Make : Model: Serial Number: Location: CERTIFIER INFORMATION Name: Client
More informationProficiency Module Syllabus. P601 - Thorough Examination and Testing of Local Exhaust Ventilation Systems
Proficiency Module Syllabus P601 - Thorough Examination and Testing of Local Exhaust Ventilation Systems Aim To provide the methodology, theoretical and practical knowledge to enable candidates to: Understand
More informationTExT Thorough Examination & Test of LEV Local Exhaust Ventilation Systems
ILEVE -Institute of LEV Engineers CPD & Information Day TExT Thorough Examination & Test of LEV Local Exhaust Ventilation Systems Jane Bastow CMIOSH Chartered Safety and Health Practitioner OSCHR Registered
More informationAirborne Activity Sampling and Monitoring at Hinkley Point A Site. David Williams, Hinkley Point A Site
Airborne Activity Sampling and Monitoring at Hinkley Point A Site David Williams, Hinkley Point A Site Presentation objectives Ventilation controls in use at Hinkley Point A Site The air sampling and monitoring
More informationLEV Inspection & Test Report
LEV Inspection & Test Report CLIENT: SITE: XXXXXXX LTD XXXXXXX Report Reference: Hinge Room-LEV System Identification: BeCu ESTA Survey Conducted By: Name: Position: Signed: XXXX Environmental Consultant
More informationHPI-4N1 NEGATIVE PRESSURE COMPOUNDING ASEPTIC ISOLATOR PERFORMANCE EVALUATION
HPI-4N1 NEGATIVE PRESSURE COMPOUNDING ASEPTIC ISOLATOR PERFORMANCE EVALUATION by Yayi Nestiti and Alexander Atmadi Esco Micro Pte. Ltd. Introduction The United States Pharmacopeias (USP) has published
More informationFAN ENGINEERING. Field Testing of Fans FE-900. Introduction. Testing Equipment. Testing Standards. Prior to Testing
FAN ENGINEERING Information and Recommendations for the Engineer Introduction There are many reasons why a fan test may be performed. AMCA publications cover three categories of tests. 1. General Fan System
More informationK V A L I F I K. Our accreditation number: NAH /2015. Valid to:
KVALIFIK Ltd. has founded in 1991. In 1993 our calibration laboratory has get the accredited status and we have calibrated standards for the generally used physical parameters. Our standards are traceable
More informationThe routine maintenance and inspection of local exhaust ventilation (LEV)
The routine maintenance and inspection of local exhaust ventilation (LEV) This document details the standards for inspection and maintenance that should be achieved for all local exhaust ventilation owned
More informationLaboratory Ventilation. Environmental, Health, and Safety
No.: BCF020.054 Page: 1 of 7 RECORD OF REVISIONS Date Rev # Details of Change 09/13 1 Updated job titles to reflect ICON job descriptions. Added a definition for Approved Ventilation Contractor and included
More informationGroup Quality Certification System of Performance Test for Clean Rooms (CR Mark)
Group Quality Certification System of Performance Test for Clean Rooms (CR Mark) KOREA AIR CLEANING ASSOCIATION 1. Overview What is the group quality certification mark of performance test for clean rooms
More informationCHAPTER 6 INDUSTRIAL VENTILATION
CHAPTER 6 INDUSTRIAL VENTILATION 1. GENERAL. Ventilation is the process of supplying and removing air by natural or mechanical means to or from any space. It is used for heating, cooling, and controlling
More informationATTACHMENT O WIPP MINE VENTILATION RATE MONITORING PLAN
ATTACHMENT O WIPP MINE VENTILATION RATE MONITORING PLAN (This page intentionally blank) ATTACHMENT O WIPP MINE VENTILATION RATE MONITORING PLAN TABLE OF CONTENTS O- Definitions... O- Objective... O- Design
More informationESTATES OFFICE OPERATIONS WORKS INSTRUCTIONS WI 6. Fume Cupboards, Ventilated Cabinets, Local Exhaust Ventilation
ESTATES OFFICE OPERATIONS WORKS INSTRUCTIONS WI 6 ISSUE RECORD Revision Description Updated Date Compiled by Review date 01 Modified Mar 2010 J Cummins Mar 2011 02 Reviewed Aug 2011 J Cummins Aug 2012
More informationIC Sentinel Applications Guide for Healthcare Environmental Air Quality Monitoring
IC Sentinel Applications Guide for Healthcare Environmental Air Quality Monitoring IC Sentinel is a real-time environmental quality monitoring solution, comprised of facilitywide, low-cost, compact, multi-sensor
More informationTWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3
TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3 The following tasks parallel the Jr. Tech (JT-1, 2, 3) description and development plan and use the Refrigeration and Air conditioning
More informationAF100. Subsonic Wind Tunnel AERODYNAMICS. Open-circuit subsonic wind tunnel for a wide range of investigations into aerodynamics
Open-circuit subsonic wind tunnel for a wide range of investigations into aerodynamics Page 1 of 4 Works with Computer, chair and work table shown for photographic purposes only (not included) Screenshot
More information2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A
2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A PROJECT ADDRESS TESTING AUTHORITY TELEPHONE Checked by/date Enforcement Agency Use GENERAL INFORMATION OF BLDG. PERMIT PERMIT # BLDG. CONDITIONED FLOOR
More informationPERFORMANCE QUALIFICATION AND OCCUPATIONAL EXPOSURE LIMIT (OEL) FOR ISOLATOR
wjpmr, 2017,3(7), 157-162 SJIF Impact Factor: 4.103 WORLD JOURNAL OF PHARMACEUTICAL Ratnesh and Vivek et al. AND MEDICAL RESEARCH www.wjpmr.com Research Article ISSN 2455-3301 WJPMR PERFORMANCE QUALIFICATION
More informationMaintenance, examination and testing of local. exhaust ventilation
Maintenance, examination and testing of local exhaust ventilation Maintenance, examination and testing of local exhaust ventilation Crown copyright 1998 First published 1990 Second edition 1998 Reprinted
More informationSTANDARDS FOR COMPRESSED GAS TESTING
STANDARDS FOR COMPRESSED GAS TESTING APPLICATION NOTE HPD-002 (US) Introduction This publication provides excerpts from some of the many guidelines and standards that pertain to compressed gases in cleanrooms.
More informationSECTION TESTING ADJUSTING AND BALANCING FOR HVAC
SECTION 23 05 93 - TESTING ADJUSTING AND [Note to PSC: Existing System Coordination When connecting to an existing system, it is the PSC s Responsibility to examine existing documents, field verify existing
More informationCRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF PRESSURE METROLOGY
CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF PRESSURE METROLOGY Approved By: Chief Executive Officer: Ron Josias Senior Manager: Mpho Phaloane Revised By: Specialist Technical Committee Date of
More informationField Evaluation of ASTM E in Relation to Control Room Habitability Testing and Boundary Maintenance in Nuclear Power Plants.
Field Evaluation of ASTM E741-00 in Relation to Control Room Habitability Testing and Boundary Maintenance in Nuclear Power Plants. Presented By Clinton B. Summers Eric M. Banks NUCON International, Inc.
More informationBiography. Abstract. Keywords. Body box, garments, validation, calibration, clean garments, IEST-RP-CC003.3, garment. Introduction and Scope
NEW METHOD CALIBRATION FOR CALIBRATION OF A BODY BOX [Paper presented at IEST s ESTECH 2003 Conference, Phoenix, AZ, May 18-21] Rajan Jaisinghani, Technovation Systems, Inc. Biography Rajan (Raj) Jaisinghani
More informationGetting the Most From Your Diagnostic Equipment
Getting the Most From Your Diagnostic Equipment Tuesday, February 20, 2007 2007 Annual RESNET Conference San Diego, CA Joe Kuonen Building Performance Institute Learning Objectives Diagnostic tools and
More informationThorough Examination and Test of Local Exhaust Ventilation Systems to Regulation 9 of the COSHH Regulations 2002 (as amended)
Thorough Examination and Test of Local Exhaust Ventilation Systems to Regulation 9 of the COSHH Regulations 2002 (as amended) Test of LEV Systems 6 Monthly Test Report Ref: LEV16012014 Date: 16 th January
More informationFeltest AirSpeed/2 Instruction manual
Feltest AirSpeed/2 Instruction manual 2 1. Table of contents 3 2. Safety instructions 4 2.1 Intended use 4 2.2 Safety precautions 4 3. About the instrument 6 3.1 Names of parts 6 3.2 Working principle
More informationP06 & P012 Pitot-Static Probes
P06 & P012 Pitot-Static Probes Operating Instructions: Measure in straight duct sections that are at least 1.5 diameters upstream and 8.5 diameters downstream of any duct disturbance such as elbows and
More informationAre you really doing your job if you fail to measure static pressure every time you service a unit? The answer is no.
GET IN TOUCH WITH YOUR AIR SIDE by Rob Falke Like a doctor taking a blood pressure reading, measuring static pressure should be at the heart of every HVAC system exam EDITOR'S NOTE TOOLS OF THE TRADE AIR
More informationP8 to P60 Pitot-Static Probes
P8 to P60 Pitot-Static Probes Operating Instructions: Install optional PX NPT fitting if required. See separate documentation for details. Measure in straight duct sections that are at least 1.5 diameters
More informationOperating instructions Pitot Static Tube
Operating instructions Pitot Static Tube halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten, Germany Phone: +49 (0) 76 61/39 63-0 Fax: +49 (0) 76 61/39 63-99 E-mail: info@halstrup-walcher.de
More informationMeasuring range Δp (span = 100%) Pa
4.4/ RLE 5: Volume-flow controller, continuous How energy efficiency is improved Enables demand-led volume flow control for the optimisation of energy consumption in ventilation systems. Areas of application
More informationCETA Compounding Isolator Testing Guide CAG Revised December 8, 2008
CETA Compounding Isolator Testing Guide CAG-002-2006 Revised December 8, 2008 1.0 Overview: The purpose of this document is to establish an industry-based minimum set of testing criteria appropriate for
More informationAutomatic Isokinetic Sampler. ST5 Evo
Automatic Isokinetic Sampler ST5 Evo Automatic Isokinetic Sampler ST5 Evo Moreover, in case of pump failure, the CU can work with a spare Dado PU unit or with any pump capable to supply the needed flowrate,
More informationPressure is our Business
Pressure is our Business Count on gauges and calibrators that perform Wherever you work Reduce Measurement Error Protect against diminished accuracy from environmental conditions, accidental damage, and
More informationNSAI Agrément Approval Scheme for. Certified Air Tightness Tester Scheme Master Document
NSAI Agrément Document Title Air Tightness Tester Page Page 1 of 10 Scheme NSAI Agrément Approval Scheme for Certified Master Document to I.S. EN ISO 9972:2015 - Thermal Performance of Buildings - Determination
More informationR2S Standard Sampling Assembly OPERATION PROCEDURE
PURPOSE 1 of 10 To describe the procedure to monitor for viable airborne bacteria with the Remote-Slit- Sampler Assembly (R2S) from EMTEK, LLC. Principle A 100 mm agar based test plate is placed on the
More informationExhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)
1 APPLICABILITY Exhibit 4 Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N) Definitions common to all certification and test procedures
More informationDESIGN AND INSTALLATION CONSIDERATIONS FOR TSI AEROTRAK VHP-RESISTANT REMOTE PARTICLE COUNTERS
DESIGN AND INSTALLATION CONSIDERATIONS FOR TSI AEROTRAK VHP-RESISTANT REMOTE PARTICLE COUNTERS APPLICATION NOTE CC-111 (A4) Introduction A widely used method to inactivate bio-contamination on surfaces
More informationSEMEM3-78 Testing and calibrating instrumentation and control equipment and circuits
Testing and calibrating instrumentation and control equipment and Overview This unit identifies the competences you need to carry out tests and calibration of instrumentation and control equipment and,
More informationSubsonic Wind Tunnel 300 mm
aerodynamics AF1300 An open circuit suction subsonic wind tunnel with a working section of 300 mm by 300 mm and 600 mm long Screenshot of the optional VDAS software Saves time and money compared to full-scale
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 CORPORATE CONSULTING, SERVICE, & INSTRUMENTS, INC. University Park, 221 Beaver Street Akron, OH 44304 Michael Kent Warner Phone: 330 376 3600 CALIBRATION Valid
More informationPacific Gas & Electric Model Energy Communities Program Air Flow & Duct Leakage Comparative Study
Prepared by: Proctor Engineering Group, Ltd. San Rafael, CA 94901 (415) 451-2480 Pacific Gas & Electric Model Energy Communities Program Air Flow & Duct Leakage Comparative Study Prepared for: PG&E Final
More informationCover Page for Lab Report Group Portion. Drag on Spheres
Cover Page for Lab Report Group Portion Drag on Spheres Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 29 September 2017 Name 1: Name 2: Name 3: [Name 4: ] Date: Section number:
More informationMet One E-BAM Particulate Monitor
STANDARD OPERATING PROCEDURES Met One E-BAM Particulate Monitor AMBIENT AIR MONITORING PROGRAM for the 130 LIBERTY STREET DECONSTRUCTION PROJECT LOWER MANHATTAN DEVELOPMENT CORPORATION 1 Liberty Plaza
More informationVertex VP Operation and Maintenance
AIRBENCH LTD Vertex VP Operation and Maintenance This Edition: 2 October 2018 AirBench Ltd, 14 Grange Farm Road, Colchester CO2 8JW www.airbench.com +44 (0) 1206 791191 Copyright AirBench Ltd 2016 Page
More informationAir Handling Unit (AHU) Air handling unit which serves to condition the air and provide the required air movement within a facility.
IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 13, Issue 5 Ver. I (Sep. - Oct. 2016), PP 28-35 www.iosrjournals.org. Heating, Ventilation and Air
More informationHatchery Tips from Jamesway s Technical Team. Essential Hatchery Tools by Phillip Perry
Hatchery Tips from Jamesway s Technical Team Essential Hatchery Tools by Phillip Perry HATCHERY TOOLS FOR A JAMESWAY HATCHERY by Phillip Perry, Consultant and Technical Advisor Phillip is a former hatchery
More information01 18/11/2013 correction of the reference of the product 1 4 5
The signed original report cancels all results and draft documents previously submitted. Each updated version of the report supersedes all previous ones. All void copies must be returned to CETIAT or destroyed.
More informationSafety Services. Introduction
Safety Services Guidance on the Selection, Installation, Maintenance and Operation of Microbiological Safety Cabinets for use in containment level 2 (CL2) laboratories Introduction 1. Microbiological safety
More informationJob Number Plant Location 123 Roadrunner Avenue, Tombstone, AR Fuel Devices
Combustion Services Safety Survey ETRO SERVICES Incorporated Customer Acme Incorporated Contact Name W. E. Coyote Job Number 5380 Plant Location 23 Roadrunner Avenue, Tombstone, AR 56884 Plant Name Test
More informationDomestic ventilation systems
A BSRIA Guide www.bsria.co.uk A guide to measuring airflow rates EXPOSURE DRAFT In Association with ED46/2013 This publication has been printed on Nine Lives Silk recycled paper. The guidance given in
More informationNuAire Model NU PR797 Positive Pressure Recirculating Compounding Aseptic Isolator Performance Evaluation Compliance to USP797
TECHNICAL BULLETIN : GENERAL INFORMATION NuAire Model NU PR797 Positive Pressure Recirculating Compounding Aseptic Isolator Performance Evaluation Compliance to USP797 Background The United States Pharmacopeia
More informationUse of Correction Factors When Commissioning Air Systems
Shaun Matthews G5 Thesis 24 th January 2016 Rev. 2 Use of Correction Factors When Commissioning Air Systems S. Matthews Grade 5 Thesis - Use Of Correction Factors Rev. 2 1 of 12 Contents Introduction What
More informationHS653 Negative Pressure Ventilation Controller
HS653 Negative Pressure Ventilation Controller General Installation Notes: Make sure that power is disconnected from system prior to servicing. Installation of this equipment and related OEM equipment
More informationDPC-30 DPC-100. Reference Manual
DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,
More informationGOOD MANUFACTURING PRACTICES FOR HEATING, VENTILATION AND AIR-CONDITIONING SYSTEMS FOR NON-STERILE PHARMACEUTICAL DOSAGE FORMS: PART 2
February 2018 Draft document for comment 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 GOOD MANUFACTURING PRACTICES FOR HEATING, VENTILATION
More information1020 Industrial Drive, Orlinda, TN fax
Operation Manual Tank Distribution System A-UPT Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.2 Warnings and Cautions... 1 1.2 Theory of Operation...
More informationConstant Pressure Inlet (CCN) Operator Manual
Constant Pressure Inlet (CCN) Operator Manual DOC-0125 Revision J 2545 Central Avenue Boulder, CO 80301-5727 USA C O P Y R I G H T 2 0 1 1 D R O P L E T M E A S U R E M E N T T E C H N O L O G I E S, I
More informationOutside Air Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program
1 Outside Air Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program Jim Meacham, CTG Energetics Agenda 2 In Situ Testing Results Reduced Ventilation after
More informationB. Diagnostic Equipment Information 01 Number of Manometers Used to Measure Home Pressurization Manometer Make. Manometer Serial Number
(Page 1 of 3) A. Building Air Leakage General Information 01 Test Procedure Used: 02 Indoor temperature during test (degreef) 03 Outdoor temperature during test (degreef) 04 Blower door location 05 Building
More informationSubsonic Wind Tunnel 300 mm
aerodynamics AF1300 TecQuipment s AF1300 Subsonic Wind Tunnel. See also AF300S starter set that includes AF1300Z Basic Lift and Drag Balance and a set of AF1300J Three Dimensional Drag Models with the
More informationSmoke and heat Ventilator Testing
Instituut vir Termodinamika en Meganika Institute for Thermodynamics and Mechanics Smoke and heat Ventilator Testing by CJ Zietsman and GR Smith November 2005 Departement Meganiese Ingenieurswese Privaat
More informationAseptic processing. the starting material to the finished product, should be controlled by Validation Control of the aseptic process
10 Aseptic processing When products are prepared aseptically in unlicensed units there is usually no possibility of quality control of the product before release and use. Consequently quality assurance
More informationCalibration certificates
Temperature Caibration certificate for temperature measuring chains consisting of a contact temperature sensor and an instrument (also individual sensors). The calibration of the sensors or sensor + measuring
More informationEMISSION SURVEY FOR SONAE NOVOBORD: WHITE RIVER. Report No. 565/12 FR.1. March 2013 C & M CONSULTING ENGINEERS PO BOX LYNNWOOD RIDGE 0040
EMISSION SURVEY FOR SONAE NOVOBORD: WHITE RIVER Report No. 565/12 FR.1 BY C & M CONSULTING ENGINEERS PO BOX 74936 LYNNWOOD RIDGE 0040 PRETORIA SOUTH AFRICA SONAE NOVOBORD 1 SUMMARY C&M Consulting Engineers
More informationValidation of a Neutral Pressure Isolation Room
Validation of a Neutral Pressure Isolation Room Andrew Fletcher, William Booth and Blanca Beato Arribas BSRIA Ltd., UK Corresponding email: Andrew.Fletcher@bsria.co.uk SUMMARY The principles behind a new
More informationEvaluation of Commercially Available Techniques and Development of Simplified Methods for Measuring Grille Airflows in HVAC Systems
LBNL 51551 ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY Evaluation of Commercially Available Techniques and Development of Simplified Methods for Measuring Grille Airflows in HVAC Systems I.S.
More informationCHAPTER 3 RESULTS AND DISCUSSION
CHAPTER 3 RESULTS AND DISCUSSION The research included the development and verification of the earlier apparatus, and the collection and validation of moisture diffusion data under both isothermal and
More informationFABRICATION OF VERTICAL AXIS WIND TURBINE WITH WIND REDUCER AND EXPERIMENTAL INVESTIGATIONS
87 CHAPTER-4 FABRICATION OF VERTICAL AXIS WIND TURBINE WITH WIND REDUCER AND EXPERIMENTAL INVESTIGATIONS 88 CHAPTER-4 FABRICATION OF VERTICAL AXIS WIND TURBINE WITH WIND REDUCER AND EXPERIMENTAL INVESTIGATIONS
More informationB. Diagnostic Equipment Information 01 Number of Manometers Used to Measure Home Pressurization Manometer Make. Manometer Serial Number
STATE OF CALIFORNIA BUILDING LEAKAGE WORKSHEET CEC-CF2R-MCH-24-H (Revised 06/14) CERTIFICATE OF INSTALLATION Building Leakage Worksheet CALIFORNIA ENERGY COMMISSION Project Name: Enforcement Agency: Permit
More informationGetting the Most From Your Duct Blaster
Bob Davis, Ecotope Bruce Manclark, Delta T The Duct Blaster, made by the Energy Conservatory, or similar devices like it, is a durable, versatile calibrated fan/flexible duct assembly that accurately measures
More informationTOPIC: KNOWLEDGE: K1.01 [2.5/2.7] An atmospheric pressure of 15.0 psia is equivalent to... A psig. B psig. C psig.
P73 An atmospheric pressure of 15.0 psia is equivalent to... A. 30.0 psig. B. 29.4 psig. C. 14.7 psig. D. 0.0 psig. ANSWER: D. P273 A pressure gauge on a condenser reads 27.0 inches Hg vacuum. What is
More informationISO 7218 INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 7218 Third edition 2007-08-15 AMENDMENT 1 2013-08-01 Corrected version 2014-04-15 Microbiology of food and animal feeding stuffs General requirements and guidance for microbiological
More informationBAPI Pressure Line of Products - FAQs
Table of Contents 1. Several manufacturers produce pressure transmitters, why should I purchase from BAPI?... p. 2 2. BAPI makes several styles of pressure transmitters. What are the features of each?...
More informationAPPENDIX A SAMPLE FHT SPECIFICATION (This recommended FHT specification is available from
SAMPLE FHT SPECIFICATION (This recommended FHT specification is available from www.nebb.org) NEBB recommends that these FHT Specifications be referenced as related documents in other appropriate sections
More informationSECTION TESTING, ADJUSTING, AND BALANCING CONTRACT NO SECTION TESTING, ADJUSTING, AND BALANCING
SECTION 15990 TESTING, ADJUSTING, AND BALANCING PART 1 -GENERAL 1.01 GENERAL A. This section of the Specifications covers testing and balancing of environmental systems, including, but not limited to distribution
More informationNZQA unit standard New US 1Non-coal of 7145 version 1 Page 1 of 5
Page 1 of 5 Title Design and maintain effective ventilation systems for a non-coal underground operation Level 5 Credits 20 Purpose People credited with this unit standard are able to: explain the principles
More informationProcedure for Field Calibration Check of Digital Pressure Gauges (Using a DG-700 or DG-500 as the Reference Standard)
Procedure for Field Calibration Check of Digital s (Using a or DG-500 as the Reference Standard) 1. Testing Apparatus Set up the (or DG-500) Standard and the gauge to be tested as shown in the diagrams
More informationMeasurement Technology
In the field of compressed air, measuring pressure provides the data basis for rating the correct pressure head of pressure differences in the distribution system as well as for controlling and regulating
More informationS-Type Pitot Tube. Operating Instructions
Tube Operating Instructions Duct diameter should be 4 inches or more. Take readings in a smooth and straight section of the duct. The section should be 1.5 duct diameters upstream and 8.5 duct diameters
More informationAnnex 8. Guidelines on heating, ventilation and air-conditioning systems for non-sterile pharmaceutical products. Background. Summary of main changes
Annex 8 Guidelines on heating, ventilation and air-conditioning systems for non-sterile pharmaceutical products Background The World Health Organization (WHO) published the first edition of the WHO Guidelines
More informationUsing the Models TA-460, PVM610, and PVM620 to Measure Pressure
Using the Models TA-460, PVM610, and PVM620 to Measure Pressure Application Note AF-107 Models TA-460, PVM 610 and PVM 620 measure differential pressure, or in other words, the pressure difference between
More informationREPORT ON ENVELOPE AIR TIGHTNESS TESTING SPORTS HALL HMP LITTLEHEY CROW SPINNEY LANE PERRY HUNTINGDON PE28 0SR CLIENT: WATES CONSTRUCTION
REPORT ON ENVELOPE AIR TIGHTNESS TESTING AT SPORTS HALL HMP LITTLEHEY CROW SPINNEY LANE PERRY HUNTINGDON PE28 0SR CLIENT: WATES CONSTRUCTION 2587 Name Position Signature Date Paul Cousins Acoustic Office
More informationProduct Guide. Crawler Crane
Crawler Crane 220 US Tons (100 Metric Tons) @ 16 ft 5 in Radius 285 ft Max Tip (Main Boom) Main Boom, Fixed Jib and Luffing Jib Configurations Product Guide KEY FEATURES ULTRA CAB The Ultra Cab, designed
More informationCover Page for Lab Report Group Portion. Lift on a Wing
Cover Page for Lab Report Group Portion Lift on a Wing Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 17 January 2017 Name 1: Name 2: Name 3: [Name 4: ] Date: Section number:
More informationInstallation Instructions
Page 5750-S-1 Installation Instructions General These mounting instructions for Circular INCINO- PAK Burners are in addition to the specific instructions offered for other Maxon component items: Shut-Off
More informationMine Foreman Training Ventilation Unit 7 Part 2 Ventilating A Mine. Program developed by Wayne Collett Office of Mine Safety & Licensing 2006
Mine Foreman Training Ventilation Unit 7 Part 2 Ventilating A Mine Program developed by Wayne Collett Office of Mine Safety & Licensing 2006 1 The purpose of mine ventilation is to provide a safe and productive
More informationPneumator. Testo Industrial Services More assurance, better service. Pressure calibrator and measuring instrument.
Pressure calibrator and measuring instrument Testo Industrial Services More assurance, better service. www.testotis.com Full versatility for industrial requirements In industrial practice, the precision
More informationRules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations
VI Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations 6 Guidelines for the Construction, Equipment and Testing of Closed Fuel Oil Overflow Systems Edition
More informationGas Measurement Fundamentals Certification. Curriculum
Gas Certification Institute, LLC P.O. Box 131525 Houston, Texas 77219-1525 281-598-7200 Phone 281-598-7199 Fax contact@gascertification.com www.gascertification.com Curriculum Copyright 2007-2012 Gas Certification
More informationSPD310/SPD360 Air Differential
SPD310/SPD360 Air Differential Pressure SPD310 / SPD360 SPD310 / SPD360 differential pressure transmitters are intended for use in air handling systems for the monitoring of air ducts, filters and fans.
More informationInstrumentation & Data Acquisition Systems
Instrumentation & Data Acquisition Systems Section 3 -Level Robert W. Harrison, PE Bob@TheHarrisonHouse.com Made in USA 1 Level Section Question Which level measuring technology is the best solution when
More informationUsing Vaporized Hydrogen Peroxide
for Bio-Decontamination D-111046-2013 Using Vaporized Hydrogen Peroxide In 1994, Dräger introduced the first electrochemical hydrogen peroxide (H2O2) sensor for monitoring low concentrations of vaporized
More informationTable of contents. I Drawings 33. A1 Design criteria 1 A1.1 Local thermal discomfort indices... 1
Table of contents A1 Design criteria 1 A1.1 Local thermal discomfort indices........................... 1 A2 Experiment set-up 3 A2.1 Equipment....................................... 3 A2.2 Test cases.......................................
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationMass Spec will not Autotune
Mass Spec will not Autotune Applies to 5973A/N MSD What could be the problem? There could be several things that would cause your Mass Spec not to Autotune. The most common, easily corrected Autotune problems
More informationP-5215 Differential Pressure Transmitter
P-5215 Differential Pressure Transmitter Pneumatic Control Manual 717.1 Pressure Section Product Bulletin P-5215 Issue Date 0891 Features and Benefits Ultra Sensitive Feedback Circuit - Enhances System
More informationThe System Curve, the Fan Curve, and the Operating Point
The System Curve, the Fan Curve, and the Operating Point AIHA-RMS Sept. 12, 2018 Keith D. Robinson, P.E. Overall Objective To equip an Industrial Hygienist with the skills necessary to document the performance
More information