TITAN FLOW CONTROL, INC.

Similar documents
TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC.

Eaton Filtration, LLC

Eaton Filtration, LLC

BS Series Basket Strainer

FloWash. Industrial Filter Cart

WHEATLEY Series 500 Swing Check Valve

North American Simplex Basket Strainers for Gas and Oil

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

FLANGED TWO-PIECE BALL VALVES

SCA Series Inverted Bucket Steam Traps

HIGH RATE BASKET STRAINER

FLANGED TWO-PIECE BALL VALVES

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

Hygienic Bubble Trap Installation and Operations Manual

FLANGED MULTI-PORT BALL VALVES

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

TP1 and TP2 Temporary Cone Shaped Strainers

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

Installation, Operation, and Maintenance Manual

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

Sterile Visual Flow Indicator

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

PP-1, PP-1W, PP-2, & PP-3

DelVal Flow Controls Private limited

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

Flange Bolt Torquing. for Resistoflex Plastic-Lined Piping Products. Torquing. Retorquing. Hydrotesting. Annual retorquing

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

WHEATLEY Series 822/820 Swing Check Valve

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

ISO 9001:2000 Certifi ed Certifi cate No. C By-Pass Pigging Valves

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

Engineering Data Sheet

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

Circular Sight Windows

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

CA10S, CA14 and CA14S Air and Gas Traps

Materials : Carbon steel ASTM A216 WCB

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

INSTALLATION, OPERATION and MAINTENANCE MANUAL

Manual Actuated Boiler Blowdown Valves

GREIG FILTERS, INC. OPERATION MANUAL

PV4 and PV6 Piston Valves

Model ASSEMBLY and OPERATING INSTRUCTIONS

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

INSTALLATION, OPERATING & MAINTENANCE MANUAL WATER DRAIN VALVE

INSTALLATION / OPERATION / MAINTENANCE INSTRUCTION

PC3_ and PC4_ Pipeline Connectors

Vertical Bladder Tanks

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

WKM Model 320F Floating Ball Valve

Models 1720A / 1760A

1805 Series Relief Valves

Model MTB-ASME Vertical Bladder Tanks

Horizontal Bladder Tanks

Models: C62/63/64-A/D

Model MTB-ASME Horizontal Bladder Tanks

MF2M Monnier Miniature Compressed Air Filter

Model MTB-ASME Vertical Bladder Tanks

Armored Gauge O S & Y Bolted Bonnet Valves Series BB-100

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

KECKLEY. Installation, Operation, and Maintenance Manual. Style KGV - Knife Gate Valve

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

Atmospheric relief valve type 1100 Installation and maintenance instructions

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

BUTTERFLY VALVES Series 800

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

Instruction Manual Pressure Relief Valve and Rupture Disc Chlorine or Sulfur Dioxide, Series 869

756 Safety Relief Valves

FV Flash Vessel Installation and Maintenance Instructions

HAYWARD FLOW CONTROL FLV SERIES, PVC/CPVC FILTER VESSEL INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Transcription:

SIMPLEX BASKET STRAINER f LANGED ENDS (R) TITAN ASME CLASS 150 f CARBON AND STAINLESS STEEL BS61-0718 MODELS: EATURES BS 61-CS ( c a r b o n steel) BS 61-SS (s ta i n l e s s steel) SIZES: 1" ~ 16" All Sizes Equipped: Quick-Open Cover Large Sizes in Stock Ready to Ship! s s BETTER LOW CHARACTERISTICS w i t h i t s d ua l a n n u l u s d e s i g n, t h e BS61 s e r i e s p rov i d e s a s t r a i g h t e r f l ow pat h. d u r i n g f l ow s i m u l at i o n t e s t i n g, t h e b s 61 ac h i e v e d a 10 p e r c e n t r e d u c t i o n i n p r e s s u r e loss when compa r e d to "ov e r-the-to p" style b a s k e t strainers. INER ILTRATIONS t h e BS61 s e r i e s i s d e s i g n e d w i t h a m ac h i n e d, f l at s e at f o r t h e s t r a i n i n g e l e m e n t. t h i s a l l ow s a n o- r i n g to b e i n s ta l l e d u n d e r n e at h t h e l i p o f t h e s t r a i n i n g e l e- m e n t, c r e at i n g a t i g h t s e a l. t h i s f e at u r e p r e v e n t s d e b r i s f ro m s l i p p i n g pa s t t h e s t r a i n i n g e l e m e n t l i p- a s i s o f t e n t h e c a s e w i t h ' s l a n t-type' b a s k e t s t r a i n e r s t h at c a n n ot utilize an o-ring. s l a r g e straining capac i t y s w i t h i t s l a r g e b o dy a n d s i z e a b l e s t r a i n i n g e l e m e n t, t h e b s 61 CS/SS h a s t h e a b i l i t y to s to r e l a r g e q ua n t i t i e s o f d e b r i s w i t h o u t a f f e c t i n g p r e s s u r e l o s s - t h u s m a x i m i z i n g time between serv i c i n g. n u m e r o u s straining element options s t r a i n i n g elements are ava i l a b l e in a va r i e t y of perforat i o n s, m e s h e s, a n d m at e r i a l s. s p e c i a l designs are also ava i l a b l e including mag n e t i c, w e d g e w i r e, d r i l l e d perforat i o n s, a n d pleat e d straining elements. s HIGH QUALITY CONSTRUCTION t h e BS61 s e r i e s is ava i l a b l e in c a r b o n and sta i n l e s s steel with either threaded or f l a n g e d ( r f) e n d c o n n e c t i o n s. c a r b o n s t e e l p e r f o r m s e x c e p t i o n a l ly w e l l i n h i g h t e m p e r at u r e s, u p to 800 i n c o n t i n u o u s s e rv i c e. i t p rov i d e s h i g h r e s i s ta n c e to s h o c k, v i b r at i o n, p i p i n g s t r a i n s, a n d f i r e a n d f r e e z i n g h a z a r d s. s ta i n l e s s s t e e l i s h i g h ly c o r ro s i o n r e s i s ta n t, e x t r e m e ly s t ro n g, a n d i s c o m m o n ly s p e c i f i e d f o r h i g h t e m p e r at u r e serv i c e, u p to 1000 i n continuous serv i c e. T TECHNICAL PRESSURE/ TEMPERATURE RATING CS - ASTM A216 GR. WCB - CLASS 150 WOG (Non-shock): 285 PSI @ 100 PRESSURE/ TEMPERATURE RATING SS - ASTM A51 GR. C8M - CLASS 150 WOG (Non-shock): 275 PSI @ 100 Carbon Steel not recommended for prolonged use above 800. Stainless Steel not recommended for prolonged use above 1000. APPLICATIONS A m a r k e t s: wat e r & wa s t e wat e r, p u l p & pa p e r, c h e m i c a l & p e t ro c h e m i c a l, p e t ro l e u m, o i l & g a s, t r a n s p o rtat i o n, m a r i n e industry, a n d food industry g e n e r a l applicat i o n: s i m p l e x b a s k e t strainers are insta l l e d into a pipeline sys t e m to remov e unwa n t e d d e b r i s fro m the pipeline flow. b a s k e t strainers are commonly used in horizonta l pipelines where debris l oa d i n g is high and the collection of solids is required. s t r a i n i n g is ac c o m p l i s h e d via a perforat e d or m e s h lined straining element, i n t e r n a l to the b a s k e t strainer. i n general, t h e size of the perforat i o n or m e s h should be slightly smaller than the smallest debris pa rt i c l e to be remov e d. i t is importa n t to not e t h at the correct size of a b a s k e t strainer is determined by its job function, n ot by the size of the pipeline. The above data represents common market and service applications. No representation or guarantee, expressed or implied, is given due to the numerous variations of concentrations, temperatures and flow conditions that may occur during actual service.

BS61-0718 TITAN CONTROL, Inc. 290 Corporate Drive E-mail: titan@titanfci.com Lumberton, NC 2858 Web: www.titanfci.com Tel: 910.75.0000 ax: 910.78.88 SIMPLEX BASKET STRAINER BS 61-CS - (Carbon Steel) BS 61-SS - (Stainless Steel) langed Ends Raised ace Carbon & Stainless Steel ASME Class 150 BILL O MATERIALS (1) No. PART BS61-CS (2) BS61-SS 1 Body Carbon Steel A216 Gr. WCB Stainless Steel A51 Gr. C8M 2 Cover Carbon Steel A216 Gr. WCB Stainless Steel A51 Gr. C8M Cover Standard: Garlock Blue Guard 000 Gasket ()() Quick Open: Buna O-Ring Quick Open: Viton O-Ring 5 2 D Centerline to Outlet A (Includes Raised ace) Eye Bolt Stainless Steel 18-8 Series 00 E Basket Removal Clearance C Centerline to Top of Cover (Does not include studs) Standard Quick Open Cover Shown. Straining () Element Type 0 Stainless Steel (Other materials are available) NPT Gauge Taps 5 Stud Alloy Steel A19-B7 Stainless Steel A20-B8 6 Nut Standard: A19-2H Quick Open: CS A105 Standard: A19-8 Quick Open: CS A105 7 Drain Plug Carbon Steel Stainless Steel 1 B Centerline to Bottom Gauge Tap BS61 with Bolted Cover Gauge Tap Body Material Application Notes: 1. Equivalent or better materials may be substituted at the manufacturer's discretion. 2. Carbon Steel bodies are epoxy painted.. Denotes recommended spare parts.. Carbon iber Compressed gasket may be substituted at the manufacturer's discretion. 7 NPT Bottom Drain NPT Side Drain DIMENSIONS AND PERORMANCE DATA (1) Size in 1 1 1 /2 2 2 1 /2 6 8 10 12 1 16 mm 25 0 50 65 80 100 150 200 250 00 50 00 A DIMENSION in 7.62 10.50 10.50 1.1 1.1 17.25 19.6 27.00 2.00.75 7 7 ACE TO ACE mm 19 267 267 8 98 686 81 857 119 119 B DIMENSION in.88 6.9 6.9 9.81 9.81 11.25 15.8 22.91 26.8.50 28.7 28.7 CTR. LINE TO BOTTOM mm 12 176 176 29 29 285 90 582 670 850 720 720 C DIMENSION in.9 5.00 5.00 6.50 6.50 6.9 768 10.25 1.91 1.75 1.8 1.8 CTR. LINE TO TOP mm 100 128 128 16 16 176 195 260 5 7 77 77 D DIMENSION in.81 5.25 5.25 6.56 6.56 8.62 9.81 1.50 16.00 16.87 2.5 2.5 CTR. LINE TO OUTLET mm 97 1 1 166 166 219 29 06.5 28.5 597 597 E DIMENSION in 7.75 11.50 11.50 16.75 16.75 18.25 2.75 5.00.50 51.75 55.12 55.12 SCREEN REMOVAL mm 197 29 29 26 26 6 601 885 110 115 100 100 DIMENSION in n/a n/a n/a n/a n/a n/a.9.72 6. 6. 9.50 9.50 MOUNTING mm n/a n/a n/a n/a n/a n/a 100 120 16 16 20 20 G DIMENSION in n/a n/a n/a n/a n/a n/a 10.6 1.56 19.68 19.68 22.5 22.5 MOUNTING mm n/a n/a n/a n/a n/a n/a 270 70 500 500 571 571 H DIMENSION in n/a n/a n/a n/a n/a n/a 0.71 0.79 0.87 0.87 0.9 0.9 MOUNTING HOLES mm n/a n/a n/a n/a n/a n/a 18 20 22 22 2 2 ASSEMBLED WEIGHT lb 22.5 9.9 6.9 69.5 110.1 207 25.1 707 916. 176.7 187.9 APPROXIMATE kg 10.2 18.1 19.5 29 1.5 50 9 19 21 16 1150 1165 low Coefficient C V 2 50 78 10 210 60 780 1250 200 00 5100 6800 1. Dimensions, weights, and flow coefficients are provided for reference only. When required, always request certified drawings. 2. ace to face values have a tolerance of ±0.06 in (±2.0 mm) for sizes 10" and lower and a tolerance of ±0.12 in (±.0 mm) for sizes 12" and larger.. Standard Vent and Gauge Plugs shall be Brass for Carbon Steel Units and Stainless Steel for Stainless Steel Units. H Mounting Holes Mounting NPT ITTING SCHEDULE: SIZE Gauge Taps Bottom Drain Side Drain Cover Vent 1" 1/8" 1/2" NA 1/8" 1 1 /2" ~ 2" 1/8" /" NA 1/8" 2 1 /2" ~ " 1/8" /" 1/2" 1/8" " 1/8" 1" 1/2" 1/8" 6" 1/" 1" 1/2" 1/8" 8" 1/" 1" 1/2" 1/8" 10" 1/" 2" 1" (1) 1/8" 12" 1/" 2" 1" (1) 1/8" 1" 1/" 2" 1" (1) 1/8" 16" 1/" 2" 1" (1) 1/8" 1. 10" and larger models have two side drains. G Mounting Pressure (PSI) 00 250 200 150 100 PRESSURE - TEMPERATURE RATING SOURCE: ASME B16.5-1 Carbon Steel A216 Gr.WCB ASME Class 150 Carbon Steel not recommended for prolonged use above 800 o Stainless Steel A51 Gr.C8MASME Class 150 Stainless Steel not recommended for prolonged use above 1000 o REERENCED STANDARDS & CODES CODE DESCRIPTION ASME B16.5 Pipe langes and langed ittings ASME B16. Valves - langed, Threaded, and Welding End. MSS SP-55 Quality Standard - Visual Inspection PRESSURE - TEMPERATURE RATING ASME CLASS 150 A216 Gr. WCB A51 Gr. C8M WOG (Non-shock) 285 PSI @ 100 275 PSI @ 100 50 0-100 50 200 50 500 650 800 950 Temperature ( ) Titan CI makes every effort to ensure the information presented on our literature accurately reflects exact product specifications. However, as product changes occur, there may be short-term differences between actual product specifications and the information contained within our literature. Titan CI reserves the right to make design and specification changes to improve our products without prior notification. When required, request certified drawings. 1100 STANDARD SCREEN SELECTIONS Size Liquid Open Area Steam Open Area 2" ~ " 1/16 (.0625) 1% /6 (.05) 6% 5" ~ 12" 1/8 (.125) 0% 0 Mesh Ln. (1).8 % 1. or 10" and above, consult factory on screen selections for steam.

PREACE: This manual contains information concerning the installation, operation, and maintenance of Titan low Control (Titan CI) Simplex Basket Strainers. To ensure efficient and safe operation of Titan CI Simplex Basket Strainers, the instructions in this manual should be thoroughly read and understood. This manual is general in nature and is not meant to take the place of an on-site, process engineer or pipe fitter. As such, Titan CI recommends that only experienced, skilled personnel be allowed to install and maintain Titan CI Simplex Basket Strainers. Please retain this manual in a location where it is readily available for reference. GENERAL INORMATION: A Basket Strainer is installed into a pipeline system to remove unwanted debris from the pipeline flow. In comparison to WYE Strainers, Basket Strainers are commonly used in pipelines where debris loading is high and the collection of solids is required. Basket Strainers can be installed in a series to provide more effective filtration of unwanted debris. Straining of the pipeline flow is accomplished via a perforated or mesh lined basket, internal to the strainer. In general, the size of the basket perforation should be slightly smaller than the smallest debris particle to be removed. If the basket perforation is undersized, the basket may require excessive cleaning. Consequently, if the basket perforation is oversized, unwanted debris may be permitted to flow through the pipeline, possibly damaging downstream equipment. The correct size of Basket Strainer is determined by its job function, not by the size of the pipeline. Prior to selection of a Titan CI Basket Strainer, the following factors must be determined: Material construction requirements of the Basket Strainer. Design and working pressure/temperature requirements. Operating conditions (throttling, pressure drop, condensation, flow reversal, operation frequency, etc.). Service media type (liquid, gas, abrasive, corrosive, dirty, etc). Pipeline Media low-rate and Viscosity. Debris Size to be removed and debris loading of the pipeline. Ability to interrupt flow for servicing and cleaning Clean Start-up Pressure of the Pipeline. Space availability for installation. Please contact a Titan Design Engineer to assist in the determination of these requirements prior to selection and purchase. igure 1: Simplifed Illustration of Installed Basket Strainer with Bolted Cover UNPACKING AND INSPECTION: Upon receipt of product, it is important to follow these unpacking and inspection procedures. All Titan CI Basket Strainers are shipped in specialized shipping containers designed to prevent damage during transportation. If external damage to the shipping container is evident upon receipt of product, please request that a representative of the shipping carrier be present before unpacking the product. Carefully open the shipping container, following any instructions that may be marked on the container. Remove all packing material surrounding the Basket Strainer and carefully lift it from the container. It is recommend to keep the shipping container and all packing material for reuse in storage or reshipment. or large or heavy Basket Strainers, the appropriate material handling equipment must be used to prevent injury and possible damage to the Basket Strainer. SIMPLEX BASKET STRAINER 1 BSIOM0709

UNPACKING AND INSPECTION: Continued... Visually inspect the Basket Strainer for any signs of damage including scratches, loose parts, broken parts or any other physical damage that may have occurred during shipment. If damage is observed, immediately file a claim with the shipping carrier. Basket Strainers that are damaged during transportation are the responsibility of the customer. or information regarding Titan CI s warranty policy, please refer to the last page of this document. Before installation, the Basket Strainer s cover should be removed and inspected internally for any loose or foreign materials that may have become trapped in the screen during transportation. After inspection, ensure sealing surfaces are clean and replace the gasket and cover. Make sure the gasket is seated correctly before tightening the cover bolts. If the Basket Strainer is not required to be installed immediately, it should be stored indoors in a clean, dry, consistent temperature environment. It is also recommended to utilize the original shipping container and packing materials to properly store the Basket Strainer. If long term storage is required, a desiccant may be necessary. This would be based upon the local, environmental storage conditions. Please consult a Titan CI Design Engineer to assist in this determination. When ready to install, remove any preservatives with solvent dampened cloths. Remove any loose material and protective packing material. INSTALLATION: Pre-Installation Checklist Ensure Working conditions (pressure and temperature) are within the specified capacity of the product being installed. Please refer to the certified Engineering drawings to assist in determining these values. Make sure that the construction material of the Strainer is chemically compatible with the media flowing in the pipeline. igure 2: Basket Strainer (abricated Design) Pre-Installation Checklist continued... Inspect the Basket Strainer s flange ends and the pipeline s mating flanges to ensure gasket surfaces are free of defects. The pipeline should also be checked for proper alignment. Titan CI Basket Strainers should never be utilized to realign an existing piping system. Ensure that the pipeline s mating flanges are the same type as the Basket Strainer being installed. Raised face flange ends cannot be mated to flat face flange ends. Ensure that the pipeline set-up allows a horizontal installation of the Basket Strainer; Titan Simplex Basket Strainers can only be installed in horizontal pipelines. If pipeline strain is a concern when installing larger Basket Strainers (6 and above), a concrete or steel pad should be used to provide additional support. Larger Basket Strainers can also be fitted with legs to assist in reducing strain on the pipeline. If the Basket Strainer is to be located on the discharge side of a pump, then a safety release valve must be installed between the Basket Strainer and the pump. SIMPLEX BASKET STRAINER 2 BSIOM0709

INSTALLATION: Continued... 1 5 Installation Procedure Step 1: Titan Basket Strainers must be positioned in the pipeline ahead of the equipment requiring protection. If the equipment requiring protection is a pump, the Basket Strainer must be placed on the suction side of the pump. Step 2: To provide for easier maintenance, the Basket Strainer should be located where the drain plug can be removed and where there is ample space above the Basket Strainer for screen removal. Refer to the certified engineering drawing to determine the screen clearance requirements. Step : Before placing the Basket Strainer into place, support the existing pipeline with pipe supports near the inlet and outlet connections of the Basket Strainer. Step : Place the Basket Strainer into the pipeline, ensuring that the flow arrow on the body of the Basket Strainer is pointing in the direction of the pipeline flow. or large or heavy Basket Strainers, lift the Basket Strainer into place using slings positioned underneath the inlet and outlet connections. Step 5: Install a standard, ANSI (1/8 thick) flange gasket between the Basket Strainer and pipeline flanges, on both sides. Install lubricated flange bolts and hand tighten. lange bolts should then be tightened, using a star or crisscross pattern to evenly load the bolts, in accordance with established piping standards. This is illustrated in igure. Excessive bolt torque may damage flanges. Please refer to established flange bolt torques for guidelines. OPERATION: Once proper installation has been successfully completed, start the system gradually, at start up as well as after shut down. This eliminates sudden shock to the strainer and other equipment in the line. Start-up Procedure: Step 1: Remove air from the pipeline by opening the blowdown valve or other vent near the Basket Strainer. 8 6 igure : Bolting Sequence Pattern With piping systems that contain fluids other than water or when the working temperature is above 120 o, fluid must be drained to safe area, away from the operator. Operators should always be fitted with appropriate protective equipment when venting is performed. Step 2: Start the piping system by opening the outlet valve nearest the Basket Strainer s outlet first. Then gradually open the inlet valve nearest the Basket Strainer s inlet, approximately 25% of normal operational flow. It is important to start the system gradually to avoid displacing or damaging the Basket Strainer. Step : Continue to open the inlet valve until the desired service flow has been reached. 2 7 SIMPLEX BASKET STRAINER BSIOM0709 Step : Close blow-down valve or other pipeline vent.

MAINTENANCE: Titan low Control Simplex Basket Strainers require little monitoring once they are properly installed. The pressure differential across the basket should be check periodically to determine if the basket needs to be cleaned or replaced. If the pressure differential goes unchecked and the screen becomes completely clogged, the screen will break and require replacing. Basket Strainer screens are not designed to withstand the same pressure ratings as the housings. If the basket becomes completely clogged, it will be exposed to the same pressure as the housing. In most cases, this will cause the basket to fail and potentially damage downstream equipment. Titan low Control Basket Strainers are designed to require very little maintenance. Regular maintenance involves: Periodically checking for leaks. Timely cleaning or replacement of screen. During normal use, the basket will become clogged with foreign matter, causing the differential pressure to increase. Once the differential pressure has increased to an unacceptable value, typically by 5 psi to 10 psi, it is time to clean or replace the basket. It is not advisable to let the differential pressure increase by 20 psi. This may cause the screen to fail and possibly damage downstream equipment. A convenient and safe way to determine when the basket needs to be replaced is to install pressure gauges on the inlet and outlet sides of the Basket Strainer. The maximum acceptable pressure drop across the Basket Strainer will indicate when the screen needs to be replaced. Basket size and construction determine the maximum pressure drop a Basket Strainer screen can withstand. Please consult factory for exact pressure ratings. Strainer Element Cleaning Strainer Element Cleaning: continued... Before removing the Basket Strainer s cover, ensure that the media that is flowing in the pipeline is known and any special handling precautions are understood. Please review the Material Safety Data Sheet (MSDS) for that specific fluid. Step 1: Isolate the Basket Strainer by closing the inlet and outlet valve connections on either side of the Basket Strainer. Step 2: Open vent or drain plug to relieve pressure inside the Basket Strainer. Drain fluid up to screen seat level. Step : Once pressure is relieved, remove the cover. Step : Remove basket and clean. Avoid banging or hitting the screen to remove stubborn debris. It is recommended to use a high pressure water or air stream to clean screen. Step 5: Inspect basket and cover gasket for damage. If either is damaged, replace. Always ensure there is a spare gasket and basket on hand prior to maintenance. Step 6: Remove any debris or sludge from within the Basket Strainer. Step 7: Replace clean basket into its original position, ensuring it is squarely positioned on the screen seat. Step 8: Replace cover gasket and replace and tighten cover. SIMPLEX BASKET STRAINER BSIOM0709 Before removing the cover of the Basket Strainer, the pressure inside the vessel must be reduced to atmospheric via suction or venting. ailure to do so may result in serious bodily injury. ollow the Start-up procedure outlined within the OPERATION section of this manual.

SPARE PARTS LIST: or the bill of materials and spare parts listing of each Basket Strainer model, please refer to the corresponding Engineering Specification Sheet. or special or fabricated units, please refer to the certified engineering drawing for that unit. 5 6 2 1 7 No. SAMPLE PARTS LIST 1 BODY 2 COVER Simplex Basket Strainer * COVER GASKET * BASKET 5* STUD 6 NUT 7 NPT PLUG 8 NPT PLUG 8 igure : CAD Illustration * Denotes recommended spare parts WARRANTY: Seller warrants each of the products and parts sold hereunder, under normal use of service, and subject to user s compliance with any operating instructions and other directions given by seller, to be free from defects in materials or workmanship for a period of one year from date of shipment from seller s plant. Seller s liability, under this warranty, shall be limited to, at the seller s option, to repairing or replacing any such defective product OB seller s plant in Lumberton, NC, and reimbursing purchaser for shipping costs, subject to the following: (1) Timely receipt of purchaser s written notice that such products are defective. (2) Seller s written authorization to purchaser for the return of such products, () the return of such products to seller with shipping charges prepaid and () seller s inspection of and confirmation that such products are defective in materials or workmanship. If seller s inspection shows that the products returned are defective due to dirt, rust or any foreign material not attributable to seller: improper usage, over tightening on threads, abuse or incorrect assembly in the field, or other cause not due to seller s improper manufacture, seller will, subject to purchaser s written authorization, repair or replace such products at cost. Seller s factory inspection and testing reports will be made available to purchaser upon request. THIS WARRANTY IS IN LIEU O ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY O ITNESS OR MERCHANTABILITY. SELLER SHALL NOT BE LIABLE OR ANY SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. NO REPRESENTATIVE OR SELLER HAS AUTHORITY TO MAKE ANY REPRESENTATIONS OR WARRANTIES, EXCEPT AS STATED HEREIN. SIMPLEX BASKET STRAINER 5 BSIOM0709