SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS
|
|
- Matthew Baker
- 6 years ago
- Views:
Transcription
1 STORAGE INSTRUCTIONS Until it is time to install a new or reconditioned valve on the car, the valve must be kept in its original packaging in order to protect it from dirt and damage. INSTALLATION INSTRUCTIONS 1. DO NOT PAINT VALVE! This may interfere with the valve s performance. 2. Before beginning any work on the car, ensure that you follow your company s and all applicable safety standards. 3. When no valve is present on the pressure relief valve opening, always protect the opening from dirt, debris, damage, etc. by placing a cover or plug over the opening and flange mating surface. 4. If stud threads are showing wear, contain burrs or are dirty, gauge the threads and replace as necessary according to the AAR Manual of Standards and Recommended Practices or your company s practices. 5. Each time a new or reconditioned valve is installed, a new gasket must be used. Carefully remove and throw away the existing gasket. 6. Before installation of the valve, examine the groove and/or gasket surface for nicks or burrs. Ensure the gasket surface is clean. It is important for the sealing of the valve that there be no interference. 7. When ready to install the valve, remove the new or reconditioned valve from its packaging and inspect the sealing surfaces for nicks or burrs. It is important for the sealing of the valve that there be no interferences. To remove nicks and burrs, the AAR does allow machining of the flat face gasket surface or tongue by a trained specialist. However, AAR specified tolerances must not be exceeded. 8. Remove the protective covering or plug from the pressure relief valve opening and install the new gasket. Carefully lower the valve onto the gasket orienting the valve bolt holes to align with the stud holes. 9. Tighten the stud nuts uniformly, alternating across from one (1) to three (3) and then two (2) to four (4). It is important to compress the gasket evenly and to not over tighten one side or the other or the gasket will not seal. 10. Torque the stud nuts to a value recommended by your engineering department. 11. Inspect the bolted connection for leaks in a method compliant with your company procedures. OPERATING INSTRUCTIONS 1. It is your responsibility to operate this valve in accordance with each applicable federal regulation and your company s instructions and procedures. 2. This valve is a spring-loaded device designed to automatically open when there is an overpressurization in the tank. The valve s internal components should never be adjusted when on a tank car. Any adjustments to the set pressure must be done while the valve is on a pressure test stand. See Maintenance/Testing Instructions. TOMBALL, TEXAS (281) of 5
2 MAINTENANCE/TESTING INSTRUCTIONS Intervals The Department of Transportation (DOT) and the Association of American Railroads (AAR) have established minimum retesting intervals for pressure relief valves. It is important that each end user of a pressure relief valve establish their own procedures and testing intervals for valves used in their particular service. The DOT and AAR regulations should be viewed as a minimum and experience with your own service conditions should be used to establish specific procedures concerning your equipment. New Valves Valves that are bought new from Salco Products, Inc. and are still in the original packaging are ready to go into service without any further testing as long as they have not been in storage for longer than six (6) months. Valves that have been in storage for longer than six (6) months should be retested following the procedure outlined below. Retesting 1. A valve that needs to be retested shall first be visually inspected for product damage, and for missing, bent, or broken parts. Damaged parts must be replaced with only Salco OEM parts. Contact Salco for replacement parts. Repair work must be limited to the AAR s Manual of Standards and Recommended Practices, M-1002, Specifications for Tank Cars, Appendix A, Section Disassembly (Refer to Figure 1.) Caution: Internal spring may be under pressure. Exercise caution when removing the Spring Holder Cut the cable seal running from the Cap Cable Seal Hole to the Flange Cable Ring To disassemble the valve, first remove the Cap using a 9/16 allen wrench Remove the Retainer using the Retainer Removal Tool (sold separately) Before removing the Spring Holder, mark the interior threads of the body to help locate the current location of the Spring Holder. This will help during the reassembly of the valve. In lieu of making a mark, a measurement from a reference location can be made to accomplish the same objective Since it is possible that the spring is under preload, care must be taken when removing the Spring Holder. Using the Spring Holder Removal Tool (sold separately), carefully remove the Spring Holder while ensuring that the pressure on the threads is equalized. Uneven pressure on either side of the Spring Holder may cause galling of the threads Remove the Washer, Spring and Stem Assembly from the Body Visually inspect the seating area inside the Body, the Stem Assembly, Washer, Spring, and Spring Holder for visual signs of damage and wear. TOMBALL, TEXAS (281) of 5
3 2.08 In accordance with the AAR s Manual of Standards and Recommended Practices, M- 1002, Specification for Tank Cars, Appendix D, Section 4.3, elastomeric materials used for gaskets or gasket seals must be replaced each time a valve is retested or taken apart. Replace the O-ring in the Stem by removing the Screw, Lock washers and Seal Holder. Use an O-ring of a compatible material with the lading. Place a small amount of a lubricant approved for service on the O-ring and reinstall it in the Stem Assembly. The Lock washers and Screw should not be reused. Replace these each time in-kind and torque to 5-6 ft-lbs. 3. Reassembly (Refer to Figure 1.) 3.01 Place the Stem Assembly with the new O-ring, Lock washers and Screw in the Body of the valve making sure the O-ring is properly seated by turning the Stem by hand Reinstall the Spring, Washer and Spring Holder in the Body using the Spring Holder Removal Tool (sold separately). Ensure that even pressure exists on both sides of the Spring Holder so that galling does not occur. Return the Spring Holder to the position that was marked/measured during the disassembly Reinstall the Retainer in the Body using the Retainer Removal Tool (sold separately) Reinstall the Cap tool tight using a 9/16 allen wrench. 4. All retesting of valves or troubleshooting of leaking valves must take place off the car and on a pressure test stand (except for leaks occurring between the valve flange and tank.) 5. Definitions (as found in the AAR s Manual of Standards and Recommended Practices, M- 1002, Specifications for Tank Cars, Appendix A): Start-to-Discharge (STD) the pressure, measured at the valve inlet, at which there is a measurable lift of the closure device on a pressure relief valve or at which discharge becomes continuous as determined by seeing, feeling, or hearing. Start-to-Leak Pressure the pressure, measured at the valve inlet of the pressure relief valve, at which the relieved fluid is first detected at the downstream side of the seat. Vapor-Tight-Pressure (VTP) the pressure, measured at the valve inlet after closing, at which no further fluid flow is detected at the downstream side of the seat of a pressure relief valve. 6. The STD pressure of each valve is indicated on the nameplate. The purpose of retesting a valve is to ensure that the valve maintains the proper STD pressure setting and that the VTP is above the minimum required. The tolerances of these values are stated in the AAR s Manual of Standards and Recommended Practices, M-1002, Specifications for Tank Cars, Appendix D. 7. The test must be performed on an appropriate pressure test stand using an appropriate gasket. Install the flange on the stand and tighten the bolts in alternating fashion (1, 3, 2, 4). 8. Using a certified test gauge per the AAR s Manual of Standards and Recommended Practices, M-1002, Specifications for Tank Cars, Appendix D, 4.5, apply the specified test pressure with a suitable gas. 9. Note the pressure at which the valve starts to discharge (STD). 10. Reduce the pressure slowly and note the pressure when the valve is bubble-tight (VTP). 11. The spring tension may need to be reset if the valve does not function within the prescribed pressure ranges as defined in the AAR s Manual of Standards and Recommended Practices, M- TOMBALL, TEXAS (281) of 5
4 1002, Specifications for Tank Cars, Appendix D, Table D2, which shall also match the nameplate on the valve. 12. Resetting the Tension on the Spring If the desired STD pressure is above where the valve starts to discharge, the spring is not under enough load and the Spring Holder and Retainer need to be tightened against the spring If the desired STD pressure is below where the valve starts to discharge, the spring is under too much load and the Spring Holder and the Retainer need to be backed off Carefully make the necessary adjustments to the Spring Holder and Retainer by using the Retainer Removal and Spring Holder Removal Tools (sold separately). Ensure that even pressure is always maintained on both sides of the Spring Holder when making adjustments so that galling does not occur in the threads The amount of adjustment should be in proportion to the difference between the set point and the actual reading. As the gap between the set point and the actual reading reduce, the amount of adjustment made should be reduced proportionally so that gradual improvements are made. 13. Repeat testing of the valve and resetting of the spring until the results from testing are consistently in the proper range. 14. After completion of the retesting, place protective coverings over the flange surface of the valve to protect it from damage and replace the cable seal by looping it through the Cap Cable Seal Hole and Flange Cable Ring. 15. Follow your company s procedures and DOT s regulations when completing all necessary documentation of the results of the retest. 16. Place the valve in protective packaging and store it in a clean, dry place until it is applied to a car. INSPECTION 1. At each loading and unloading of the tank car, it is appropriate to visually inspect the pressure relief valve for visual indications of damage, debris, corrosion, and cracks. 2. Should any signs of deterioration of the valve be present at any time, the valve should be removed from the car and subjected to a full inspection and retest. TOMBALL, TEXAS (281) of 5
5 NO. 1 PART NAME CAP 2 RETAINER 3 4 SPRING HOLDER WASHER SPRING STEM 7 O-RING 8 SCREW 9 SEAL HOLDER 10 LOCK WASHER 11 BODY 12 CAP CABLE SEAL HOLE FLANGE CABLE RING NAMEPLATE 14 TONGUE AND GROOVE FLANGE OPTIONAL FIGURE 1 TOMBALL, TEXAS (281) of 5
WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual
WHEATLEY SERIES 500 SWING CHECK VALVE STANDARD INTEGRAL SEAT & OPTIONAL REMOVABLE SEAT 2" FP - 6" FP 150# - 1500# 8" FP - 12" FP 150# - 900# API 6D and B16.34 2" FP - 4" FP 5000# DRILLING PRODUCTION VALVE
More informationPressure Relief Valves
Instructions for NGRTC EXTERNAL-STYLE Valve A-14378-ML A-14308-ML A-14228-ML A-1403 series A-1406 series Installation Operation Doc. No. A-14378, Supersedes: Rev. 1.0, 02/16 ITEM QTY PART NAME 1 1 TOP
More informationInstallation, Operation and Maintenance Manual for Back Pressure Regulator
Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN
More informationLarge Internal-Style Pressure Relief Valve A-3000, A-3100, A-3200, A-3400, A & A Series
Part Number: A-3000-M, Rev. 3.7 Issue Date: July 23, 2018 Supersedes: A-3000, Rev. 3.6 Large Internal-Style Pressure Relief Valve A-3000, A-3100, A-3200, A-3400, A-35000 & A-37000 Series Installation,
More informationExternal-Style Pressure Relief Valve
Document Number: A-1402C, Rev. 1.2 Issue Date: September 27, 2016 Supersedes: Rev. 1.1 Page 1 of 30 External-Style Pressure Relief Valve A-1402C Series Installation, Operation & Maintenance Manual 7733
More informationInternal-Style Pressure Relief Valve A Series and A Series
Part Number: A-22075/6, Rev. 1.1 Issue Date: July 25, 2016 Supersedes: A-22075/6, Rev. 1.0 Internal-Style Pressure Relief Valve A-22075 Series and A-22076 Series Installation, Operation and Maintenance
More information1.0 - OPENING AND CLOSING THE DOOR
The purpose of this manual is to provide the user with instructions on how to safely open and close, how to conduct routine maintenance, and how to install the PEI TWINLOCK Closure on a pressure vessel.
More informationINDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES
INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts
More informationWHEATLEY Series 500 Swing Check Valve
Document Number: TC003001-13 Revision: 02 WHEATLEY Series 500 Swing Check Valve Installation, Operation, and Maintenance Manual TABLE OF CONTENTS BILL OF MATERIALS...3 SCOPE...5 INSTALLATION AND OPERATION
More informationINSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES
PBV-USA,Inc. 12735 Dairy Ashford. Stafford, Texas USA 77477 281-340-5400; 800-256-6193 FAX: 281-340-5499 INDUSTRIAL BALL VALVES IM0 69 April 2001 Rev 9 INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS
More informationInstallation Instructions For Flat Seated Bolted Type RAH Series Disk Holders
Installation Instructions For Flat Seated Bolted Type RAH Series Disk Holders RA Series Rupture Disks 1. WARNING a) Read the complete instructions before attempting to install the rupture disk and holder
More informationTITAN FLOW CONTROL, INC.
PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Simplex Basket Strainers. To ensure efficient and safe operation of Titan
More informationINSTALLATION, OPERATION AND MAINTENANCE GUIDE
INSTALLATION, OPERATION AND Placement in Pipeline System When installing Process Development & Control s ElastoTITE Elastomer-Hinged Check Valves in a pipeline, a minimum of five pipe diameters should
More informationModels: C62/63/64-A/D
Installation & Service C62-991-24A3 Models: C62/63/64-A/D Diaphragm Bypass Pressure Regulating Valves IMPORTANT Record your pump model number and serial number here for easy reference: Model No. Serial
More informationInstallation Troubleshooting Maintenance Instructions Installation / Start-up
Model ZW207 Installation Troubleshooting Maintenance Instructions Installation / Start-up NOTE: Flushing of all pipe lines is to be performed to remove all debris prior to installing valve. 1. For making
More informationHydraulic Piston Accumulators
Ride Control Engineering Services PWCE Extendavator Paul Wever Construction Equipment Co., Inc. P.O. Box 85 401 Martin Drive Goodfield, IL 61742-0085 Phone (309) 965-2005 Fax (309) 965-2905 1-800-990-PWCE
More informationExternal-Style Pressure Relief Valve A Series. Installation, Operation & Maintenance (IOM) Manual. P/N: A-19075, Rev. 2.2
P/N: Issue Date: September 26, 2018 Supersedes: A-19075, Rev. 2.1 External-Style Pressure Relief Valve A-19075 Series Installation, Operation & Maintenance (IOM) Manual Manual content is subject to change.
More informationEASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:
2 Table Of Contents 1. Introduction 3 2. About this Manual 3 3. Contacting YZ Systems 3 4. Vessel Components 4 5. Specifications 5 6. Application 6 7. Theory of Operation 7 8. DuraSite Installation & Use
More information1700ESL Kamvalok Coupler
PART #H32138PA November 2008 1700ESL Kamvalok Coupler OPW Transport Series Dry Disconnect Couplings are considered the standard of the industry. For use on multi-compartment petroleum, solvent and chemical
More informationAssembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &
REDQ Regulators Model 411B Barstock Design Powreactor Dome Regulator OPERATION AND MAINTENANCE Contents Scope..............................1 Installation..........................1 General Description....................1
More informationWafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1
Serial No. H-V066-E-3 Wafer Check Valve User s Manual Contents (1) Be sure to read the following description of our product warranty 1 (2) General operating instructions 2 (3) General instructions for
More informationAtmospheric relief valve type 1100 Installation and maintenance instructions
SAPAG 1. Description Sapag atmospheric relief valves type 1100 have been selected for installation because of their performance features, reliability and ease of maintenance. They are designed to protect
More informationSCUBAPRO. Balanced Power Inflator
SCUBAPRO Balanced Power Inflator USE THIS GUIDE AS A REFERENCE WHEN SERVICING THE BALANCED POWER INFLATOR Important note: The following information is not designed to be a complete training guide for servicing
More informationApollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual
I854000.D Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual Introduction This manual presents guidelines for the Installation, Operation and
More informationNeedle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2
Serial No. H-V024-E-7 Needle valve User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for transportation,
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Pressure Vacuum Thief Hatch & Combo. Gauge Hatch SECTION I
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Model 2199 Pressure Vacuum Thief Hatch & Combo. Gauge Hatch IOM-2199 09-17 ISO Registered Company SECTION I I. DESIGN AND FUNCTION The Model 2199 is an inexpensive,
More informationRHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.
RHPS Series RD(H)F40 User Manual Read the complete manual before installing and using the regulator. 2 WARNING Before removing a regulator from the system for service, you must depressurize system purge
More informationInternal-Style Pressure Relief Valve A-1076/A-1281 Series. Installation, Operation & Maintenance (IOM) Manual. P/N: A-1076/A-1281, Rev. 2.
P/N: Issue Date: April 10, 2018 Supersedes: A-1076/A-1281, Rev. 2 Internal-Style Pressure Relief Valve A-1076/A-1281 Series Installation, Operation & Maintenance (IOM) Manual Manual content is subject
More information1200B2 Series Service Regulators. Instruction Manual
00B Series Service Regulators Instruction Manual 00B Series Service Regulators 0 Elster American Meter 00B Series Service Regulators General Information The 00B Series Service Regulators are available
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL
INSTALLATION, OPERATION & MAINTENANCE MANUAL AWWA C500 SOLID WEDGE GATE VALVE 2 72 NRS and OS&Y Series 100 and Series 105 TABLE OF CONTENTS SECTION PAGE # Equipment List 2 General 3 Receipt and Inspection
More informationRHPS Series PRV 6 User Manual
RHPS Series PRV 6 User Manual Read the complete manual before installing and using the valve. 1 WARNING Before removing a valve from the system for service, you must depressurize system purge the system
More informationTBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:
TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE For technical questions, please contact the following: Engineering Department 1537 Grafton Road Millbury, MA 01527 Phone: (508) 887-9400
More informationRHPS Series PRV 2 all types of connections User Manual
RHPS Series PRV 2 all types of connections User Manual Read the complete manual before installing and using the valve. Before removing a valve from the system for service, you must depressurize system
More informationAnderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions
Before installation these instructions must be fully read and understood Installation and maintenance instructions for Series 93 Positive Pressure Pilot Operated Safety Relief Valves (POSRV). The intent
More informationInternal-Style Pressure Relief Valve A-1000 Series. Installation, Operation & Maintenance (IOM) Manual
P/N: Issue Date: April 10, 2018 Supersedes: A-1000, Rev. 3.1 Internal-Style Pressure Relief Valve A-1000 Series Installation, Operation & Maintenance (IOM) Manual Manual content is subject to change. Visit
More informationMODEL PAF 450 ASSEMBLY
INSTALLATION, OPERATION, & #: MM-PRV003 11/17/09 Rev. C MODEL PAF 450 ASSEMBLY PART NUMBERS (Including, but not inclusive) FVA9710 _, FVA9716_X_, FVA9742_X_, FVA9820_X_, and FVA9863_X_ Page 1 of 13 MODEL
More informationTHE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)
THE BP-301 SERIES Operating and Service Manual Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) Issue B October 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation...
More informationKTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be fully read and understood SECTION 1 - STORAGE 1.1 Preparation and preservation for storage All valves should be properly packed in order to protect the parts
More informationBUTTERFLY VALVES Series 800
BUTTERFLY VALVES Series 800 WARNING Before proceeding read ALL instructions and become familiar with the equipment and associated drawings. Follow ALL applicable safety regulations and codes for pressurized
More informationAPCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A
APCO ARV CLEAN WATER AIR RELEASE VALVES Model 50A Instruction D12013 February 2017 Instructions These instructions provide installation, operation and maintenance information for APCO ARV Clean Water Air
More informationMODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL
MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL Index 1. List of components / General arrangement 2. Description 3. Handling 4. Installation 5. Actuators / Operation 6. Maintenance a. Changing
More informationRS(H)20, 25 USER MANUAL
RS(H)20, 25 USER MANUAL Read the complete manual before installing and using the regulator. WARNING Before removing a regulator from the system for service, you must depressurize system purge the system
More informationTITAN FLOW CONTROL, INC.
PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) WYE Type Strainers. To ensure efficient and safe operation of Titan FCI
More informationTHE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301
THE HF-300 SERIES Operating and Service Manual Series includes all variants of HF-300/301 Issue A July 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 3.1. Spring Loaded...
More informationRS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.
RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationModel 3600 IOM Vacuum Relief Vent Side-Mounted Connection SECTION I I SERIES DESIGN AND FUNCTION
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Model 3600 Vacuum Relief Vent Side-Mounted Connection IOM-3600 01-17 ISO Registered Company SECTION I I. 3000 SERIES DESIGN AND FUNCTION MODEL P V DESCRIPTION
More informationOperation Manual Piston Sensed Gas Pressure Regulators
687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Operation Manual Piston Sensed Gas Pressure Regulators (Models KT9, KT10, Welded KT10, KT12) Table of Contents:
More informationType S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual
Fisher Controls Instruction Manual Type S301 & S302 Gas Regulators October 1981 Form 5180 WARNING Fisher regulators must be installed, operated, and maintained in accordance with federal, state, and local
More informationTorque Specifications
SENR3130-10 Torque Specifications All Caterpillar Products S/N From the library of Barrington Diesel Club CONTENT General Information 01/07/2005 Introduction to Torque 01/07/2005 Torque-Turn 01/07/2005
More informationEaton Filtration, LLC
Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Phone: 908-787-1000 Fax: 908-351-7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Installation, Operation & Service Manual
More informationSummary of Accumulators These operating instructions apply to the accumulators listed in the table shown below.
Page 1 of 15 Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below. Model Number A25-XXXX-3.6K Series A40-XXXX-3K Series A40X-XXXX-3.6K Series A60-XXXX-3K
More informationModel: 43T. Bermad Pressure Relief Valve
Model: 43T Bermad Pressure Relief Valve Installation Operation Maintenance Manual () Rev.C1_01.08.17 Page 1 of 10 Safety First BERMAD believes that the safety of personnel working with and around our equipment
More informationProduct Bulletin No.: D99-RRV2015-PIB-001
Product Bulletin No.: D99-RRV2015-PIB-001 Titan BX Automatic Pressure Relief Valves Issue Date: April 22, 2016 Subject: Product: Affected Assemblies Objectives: Structural failure of a Titan Type BX pneumatically-operated
More informationLIQUIP DRYBREAK COUPLER. API800 Series MAINTENANCE INSTRUCTIONS
LIQUIP DRYBREAK COUPLER API800 Series MAINTENANCE INSTRUCTIONS API LOADING COUPLER TO API RP1004 June 2015 Issue: F M:\Product-Info\API8xx\6-Service-Maintenance\API800 MAINTENANCE INSTRUCTIONS 40183.doc
More informationKIRBY MORGAN DEEP SEA DIVING HELMETS ALL MODELS OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A
KIRBY MORGAN DEEP SEA DIVING HELMETS ALL MODELS OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A2.1 05-23-17 THIS INSPECTION AND MAINTENANCE SHOULD BE PERFORMED AT LEAST ANNUALLY AND AS DICTATED
More informationType ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002
Installation Guide English May 2002 Type ACE97 Introduction This installation guide provides instructions for installation, startup, and adjustment. To receive a copy of the instruction manual, contact
More informationReduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections
VALVCHEQ Backflow Preventers Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections Features General application The RP03 provides protection from both
More informationKENNEDY VALVE OPERATION & MAINTENANCE MANUAL
2 54 ROTATING DISC GATE VALVE OPERATION & MAINTENANCE MANUAL Rel. 5/27/16 1 TABLE OF CONTENTS 3 General 3 Receipt & Inspection 4 Gate Valve Storage & Handling 5 6 Installation 7 Operation 8 Field Testing
More informationInstallation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Welker Probe Instrument Regulator Model The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for
More informationModel PIV UL/FM Post Indicator Valve. Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515
Model 2010 -PIV UL/FM Post Indicator Valve Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515 2 LAYOUT AND SITING At the design stage, it should be considered where valves
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Model 1100 Sanitary Vent IOM-1100 03-17 ISO Registered Company SECTION I I. DESCRIPTION AND SCOPE The Model 1100 is a stainless steel sanitary vent designed
More informationEngineering Data Sheet
Page 1 of 6 CE MARKING AND THE PRESSURE EQUIPMENT DIRECTIVE 97/23/EC Valves must be installed into a well designed system and it is recommended that the system be inspected in accordance with the appropriate
More informationThreaded Closures Installation, Operation & Maintenance
Howard Street Bulletin TT Louisville, KY 0 USA Revised Jan 0 Phone 0--0 Fax 0--00 Threaded Closures Installation, Operation & Maintenance Caution: Operating a closure can be a hazardous activity and certain
More informationLIQUIP DRYBREAK COUPLER. LYNX Series MAINTENANCE INSTRUCTIONS
LIQUIP DRYBREAK COUPLER LYNX Series MAINTENANCE INSTRUCTIONS API LOADING COUPLER TO API RP1004 February 2016 Issue: DRAFT A Issue: DRAFT - A 02/01/16 Page 1 CONTENTS LYNX Series Datasheet... 3 LYNX Series
More informationPressure Dump Valve Service Kit for Series 2300 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit
More informationINSTALLATION, OPERATION and MAINTENANCE MANUAL
INSTALLATION, OPERATION and MAINTENANCE MANUAL TRUNNION MOUNTED BALL VALVE NEXTECH I ValvTechnologies, Inc. 5904 Bingle Road Houston, Texas 77092 U.S.A. Email: sales@valv.com www.valv.com 705_Nextech IOM
More informationGREIG FILTERS, INC. OPERATION MANUAL
GREIG FILTERS, INC. OPERATION MANUAL MODEL DCFH 3P 15/3 100 S4 DOE/222 DUAL CARTRIDGE FILTER HOUSING TABLE OF CONTENTS I. INTRODUCTION II. CARTRIDGE FILTER HOUSING UNIT A. OPERATION B. INSTALLATION C.
More informationHorizontal Bladder Tanks
DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationDifferential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN
Differential Pressure Regulator Type 45-6 Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Edition March 2008 Contents Contents Page 1 Design and principle of operation...................
More informationWW-720. Pressure Reducing Control Valve
WW-720 Pressure Reducing Control Valve (Size Ranges: 2-4 and 6-14 ) Installation Operation & Maintenance Page 1 of 6 1. DESCRIPTION The Model 720 Pressure Reducing is an automatic control valve (powered
More informationVertical Bladder Tanks
DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationFLANGED TWO-PIECE BALL VALVES
INTRODUCTION This instruction manual includes installation, operation, and maintenance information for FNW flanged split-body ball valves. This manual addresses lever operated ball valves only. Please
More informationHygienic Bubble Trap Installation and Operations Manual
Hygienic Bubble Trap Installation and Operations Manual Darren Bean / J. LaFleur 1/1/2010 Table of Contents 1.00 Warranty... 1 1.10 Exceptions... 1 1.20 Provisions... 1 2.00 Components... 1 2.10 Exploded
More informationTHE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691
THE BP-690 SERIES Operating and Service Manual Series includes all variants of BP-LF/MF-690/691 Issue B April 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special
More informationAluminum 13 cu tank Includes regulator Fill pressure: 3,000 psi (200 bar) Output: 1,100 psi +/- 10% (75bar)
Aluminum 13 cu tank Includes regulator Patent numbers: 6,851,447 7,059,343 7,051,751 Fill pressure: 3,000 psi (200 bar) Output: 1,100 psi +/- 10% (75bar) Contents Safety system... 3 Fill your tank... 4
More informationInstallation Instructions
Installation Instructions Durametallic MD-200 Series Gas Dual Cartridge Canister Seal for Mixers and Agitators Experience In Motion 1 Equipment Check 1.1 Follow plant safety regulations prior to equipment
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE MODELS RV-1 RV-2 RV-2CP RV-3 DRAWING NUMBERS AD017A[ ] AD018A[ ] AD020A[ ] AD282BO MANUAL NUMBER IOM-033 REVISION Rev. E, 3/28/2016 TABLE
More informationSAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE
SAPAG IMPORTANT NOTICE Contents Important notice 1 0 Valve identification 2 1 Storage 2 2 Installation 2 3 Operation 2 4 Maintenance 3 4.1 Dismantling 3 4.2 Inspection 3 4.3 Repair 3 4.4 Assembly 4 4.5
More informationLRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.
LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Gauge Hatch SECTION I SECTION II
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Model 2100 Gauge Hatch IOM-2100 01-17 ISO Registered Company SECTION I I. DESIGN AND FUNCTION Model 2100 is primarily designed to provide easy access into
More informationDIRECT DRIVE DIXIE DOUBLE SEAMER Model 25D
OPERATOR'S MANUAL DIRECT DRIVE DIXIE DOUBLE SEAMER Model 25D LUBRICATE DAILY: A. Gears inside gear housing at chuck shaft (1) Oil B. Seam rolls and cam rolls (4) - Oil C. Seam roll levers through gear
More informationPRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.
PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationVALVCHEQ BACKFLOW PREVENTERS FIGURE RP03
Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections FEATURES GENERAL APPLICATION The RP03 provides protection from both backsiphonage and backpressure
More informationFLANGED TWO-PIECE BALL VALVES
INTRODUCTION This instruction manual includes installation, operation, and maintenance information for FNW flanged split-body ball valves. This manual addresses lever operated ball valves only. Please
More informationKIRBY MORGAN DEEP SEA DIVING HELMETS ALL MODELS OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A
KIRBY MORGAN DEEP SEA DIVING HELMETS ALL MODELS OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A2.1 9-22-15 THIS INSPECTION AND MAINTENANCE SHOULD BE PERFORMED AT LEAST ANNUALLY AND AS DICTATED
More informationPP-1, PP-1W, PP-2, & PP-3
Welker Pitot Probe Model PP-1, PP-1W, PP-2, & PP-3 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for the installation, operation, and maintenance
More informationPressure Dump Valve Service Kit for Series 3000 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator
More informationCrosby style JCE Safety Valve Installation, Maintenance and Adjustment Instructions CROSBY
CROSBY Table of contents 1. Installation 1 1.1. Drainage 1 1.2. Discharge pipework 1 1.3. Preparation for installation 1 2. Pressure adjustment 1 3. Maintenance 1 4. Dismantling 1 4.1. All valve types
More informationINSTRUCTION MANUAL. Anchor Darling 800 Globe Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM
INSTRUCTION MANUAL Anchor Darling 800 Globe Valves Sizes 1/2 through 2 Installation Operation Maintenance FCD ADENIM0008-00 Revision Record Revision Section Description Date - All Original Issue 04/02/2004
More informationDelVal Flow Controls Private limited
DelVal Flow Controls Private limited (A DIVISION OF DelTech CONTROLS LLC, USA) DelVal Series 50/5, 5A/5B Butterfly Valves INSTALLATION, OPERATION AND MAINTENANCE MANUAL ENGINEERING DATA SHEET E.D.S. NO
More informationType CT88 Backpressure Regulator
Instruction Manual Type CT88 July 2016 Type CT88 Backpressure Regulator Table of Contents Introduction...1 Specifications...2 Principle of Operation...2 Installation...3 Overpressure Protection...4 Startup...4
More informationMEGR-1627 Instruction Manual
MEGR-1627 HIGH FLOW GAS REGULATOR Instruction Manual- Look Inside For: Description Installation Remote Vent Line Installations Startup and Adjustment Shutdown Maintenance Body Maintenance Procedures Diaphragm
More informationMAINTENANCE PROCEDURE FOR X 650
MAINTENANCE PROCEDURE FOR X 650 X 650 25. juli 2005-1/6 MAINTENANCE PROCEDURE FOR X 650 2 ND STAGE WARNING: This maintenance procedure is only for appointed Scubapro technicians that completed a course
More information1800C and 1800C-HC Series Service Regulators
1800C and 1800C-HC Series Service Regulators Installation Instructions www.elster-americanmeter.com General Information: The 1800C and 1800C-HC Regulators are available as Full Capacity Internal Relief
More informationModel MTB-ASME Vertical Bladder Tanks
DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationWW-720. Pressure Reducing Control Valve
WW-720 Pressure Reducing Control Valve (Size Ranges: 2-4 and 6-14 ) Installation Operation & Maintenance Page 1 of 6 1. DESCRIPTION The Model 720 Pressure Reducing is an automatic control valve (powered
More informationPreparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable
GEP-6075 Rev. B 101574 Ref. I.D.: 16973 Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable WARNING USER SHOULD READ AND THOROUGHLY UNDERSTAND THESE
More information15ME-014 INSTRUCTION MANUAL OF STERN TUBE SEALING TYPE EVK2RV. URL
15ME-014 E INSTRUCTION MANUAL OF STERN TUBE SEALING TYPE EVK2RV URL http://www.kemel.com CONTENTS [A] Installation [B] Piping [C] Inspection [D] Handling [E] Parts replacement intervals [F] Handling check
More informationLRS(H)4 Pressure-Reducing Regulator User Manual
LRS(H)4 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be considered
More information299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012
Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of
More information