Residential Road_Lighting Class S5

Similar documents
SPORTS: Single Tennis court 24x11m for class III

SPORTS: Single Tennis court 24x11m for class III

CONTOUR SPECIFICATION

LUMILUX T5 HO CONSTANT

QTi DALI/DIM / QTi GII / QTP5

Less power great performances

SIROCCO. Robust high-pressure diecast aluminium housing. Computer aided design reflector. Graduated scale for accurate aiming.

Convia. A sparkling innovation along the road.

QTi DALI/DIM / QTi GII / QTP5

WE-EF LEUCHTEN General Catalogue Asia Paci c Edition Tennis Court Lighting

QT-FIT8 2X58-70/ VS20

QT-FIT8 2X58-70/ VS20

QTi DALI/DIM / QTi GII / QTP5

DULUX L LUMILUX DE LUXE

LED Lightsource-R High Bay - EU

LED Lightsource-R High Bay - EU

CEAG HandRail LED. Hand rail mounted Luminaire for all applications

CURION 185 FIXED Colour White = MW Matte White RAL 9016 Colour Black = BL Matte Black RAL 9005 Beam Angle 80 EN60598 / EN62031 / EN62471 >25 >25.

DULUX L LUMILUX IMPROVED LIFETIME & SYSTEM GUARANTEE. DULUX L LUMILUX & QUICKTRONIC TECHNICAL INFORMATION 1.

HCI-T 70 W/942 NDL PB

HCI-T 70 W/942 NDL PB

HCI-TT 250 W/942 NDL PB

POWERBALL HCI -T. Technical Information. POWERBALL HCI -T for enclosed fixtures.

LED lighting systems

POWERBALL HCI -TC. Technical Information. POWERBALL HCI -TC for enclosed luminaires.

POWERBALL HCI -T. Technical Information. POWERBALL HCI -T for enclosed luminaires.

SDGOG SDGLK. Device mount with indirect component

FL200 Monochromatic Architectural Spot and Floodlight

Photometric Test Report

PrevaLED Linear Slim 2

ChromaLit Extruded Linear

LED FLOOD LIGHTING SPORTS LIGHTING CASE STUDY. Yankee Stadium. New York USA

POWERBALL HCI-T. Product family datasheet. Metal halide lamps with ceramic technology for enclosed luminaires

DRIVER VOLTAGE DRIVER TYPE. DM v Low Voltage Dimming (10% - 100%) (Standard) LV - Line Voltage Dimming *Specify Voltage (120v or 277v)

POWERBALL HCI-T. Product family datasheet. Metal halide lamps with ceramic technology for enclosed luminaires

DRIVER VOLTAGE DRIVER TYPE. DM v Low Voltage Dimming (10% - 100%) (Standard) LV - Line Voltage Dimming *Specify Voltage (120v or 277v)

HALODIUM II. Product family datasheet. Outdoor flood- and spotlights. Areas of application _ Facades and monuments _ Parks

CABRIO LAMPS REFLECTORS CHARACTERISTICS LUMINAIRES LIGHT DISTRIBUTION THREE SIZES, MULTIPLE PHOTOMETRIC SOLUTIONS

Technical data: SCHUCH quality - Your advantage:

LIMBA SUSPENDED LUMINAIRES

Experience bright and vivid colors

Technical data: SCHUCH quality - Your advantage:

RobLight FL 1500 B-2. User manual. Applies to: RobLight A/S Nordhavnsvej 1A DK Frederikshavn. Phone:

BSM SEAL. Kitchens, bathrooms, saunas, porches, balconies and similar high humidity environments. IP65 SMALL RECESSED DOWNLIGHTS

Dialight LED Conveyor Light - CE / RCM. for Indoor and Outdoor Industrial Applications

Light Engines. Data Sheets. Nix II Series. Oberon II Series. Pluto II Series. Titan II Series. Mercury II Series. Aries II Series.

POWERED BY IP66 IK08 LM-80 LED URBAN LIGHT. LED Urban Light

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

LED Down Light (8 ) Dimension:

EX-RECESSED CEILING LIGHT FITTINGS

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

MultiWoody design Mario Cucinella

Assolo parete soffitto

LED Modules. Fortimo LED Line High Flux PR. 2ft 4000lm 1R NA

POWERSTAR HQI -TM 600 and 1000W POWERBALL HCI -TM 250 and 400W

Datasheet. Inground. The Inground series is an LED luminaire for in-ground installation for a variety of architectural applications.

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

MIMIK 20 MIMIK 30 MADE IN ITALY

Compact pressure switches for gas and air

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

Bollards. by Collingwood Lighting. Mastering light together. collingwoodlighting.com

COMFORT LED. The new TECO range

code: NEWS _EN s/p LED 2016 NEWS 02 -EN

LED Product Guide. LED Lamps LED Luminaires

Operating Instructions

High Pressure Breathing Air Compressors

TECHNICAL MANUAL. DHR70N Polar. Den Haan Rotterdam

Photometric Data of Lamp

(Certification N:o VTT 08 ATEX 066 or IECEx VTT )

Table of Contents. Version 5.1. Mounting Hardware 9-10 Aluminum 9 Plastic 9 Plastic & Aluminum 10

IECEx Certificate of Conformity

NITELED CURVE BOLLARD NITELED DOME BOLLARD NITELED NITELED DOME BOLLARD NITELED ROUND TOP BOLLARD

Mass Flows of Selected Target Materials in LED Products

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Prewired position switches FA series

Position switches FP series

HBLT-A1 LIQUID LEVEL SENSOR

Actuating elements for ComEx

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Cualiti Photo Studio

User manual. PCA EXCEL one4all with corridorfunction PCA T5 ECO lp with corridorfunction TE one4all with corridorfunction

TEST REPORT. ACCORDING TO IES LM For. Samsung Electronics Co., LTD. 1,Samsung-Ro,Giheung-Gu,Yongin-City,Gyeonggi-Do 17113, Korea

Blackfalds Downtown. Architectural Guidelines: Streetscape

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

L230 LED 40 Watt Searchlight

In Ground Buried Uplights

CHAPTER 8 STAKING SIGNALS AND LIGHTING FIELD GUIDE. 8.1 Staking Traffic Control Signal Systems

Technical information

Sloped Ceiling Recessed Fixtures. LED Housings and LED Inserts Medium Base Housings and Trims

Cualiti Photo Studio

Product Description TUV PL-L

A60 A65 YEAR MODEL. 100 mm VT w SKU: K WARM WHITE SKU: K DAY WHITE SKU: K WHITE. 37 mm MODEL SHAPE A60 VT

Mistral LED. Exterior Amenity Luminaires.

The same, but better. Much better.

D-Sub Vertical Surface Mount Connectors RoHS compliant Economical Interface Solution for SMT Applications

Adjustable swirl diffuser ODZA TECHNICAL DATA

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

Pressure Switches Application Guideline

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Transcription:

Residential Road_Lighting Class S5 Customer : Processed by : Siteco Light Consulting Project description: Lighting Class S5 according to DIN EN 13201:2005 Luminaire: Streetlight Micro 10 Plus 5XA5803K1B08 4000K Maintenance factor: 0,94 Width of Road = 6m Mounting height = 4,50m Luminaires outreach = -1,5m Luminaire spacing = 32 m The determination of the lighting results is performed on a sales support basis, with great thoroughness, using the documents at our disposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux). A guarantee / warranty / liability for this free calculation is not provided by SITECO. In this respect, we refer to the services of the light planning and engineering office. The following values are based on exact calculations on calibrated lamps, luminaires and their arrangement. In practice, gradual divergences can occur. Guarantee claims for luminaire data are excluded. Relux and the luminaire manufacturers accept no liability for consequential damage and damage which is occasioned to the user or to third parties. Page 1/8

Table of contents First Page 1 Table of contents 2 1 Luminaire data 1.1 Siteco, Streetlight 10 micro LED (5XA5803K1B08) 1.1.1 Data sheet 3 2.1 Description, Residential Road_S5 2.1.1 Floor plan 4 2.1.2 3D view, View from the left 6 2.2 Summary, Residential Road_S5 2.2.1 Result overview, Road 7 2.3 Calculation results, Residential Road_S5 2.3.1 Table, Road (E horizontal) 8 Page 2/8

1 Luminaire data 1.1 Siteco, Streetlight 10 micro LED (5XA5803K1B08) 1.1.1 Data sheet Manufacturer: Siteco 5XA5803K1B08 mast luminaire-pylon top Streetlight 10 micro LED Streetlight 10 micro LED, mast luminaire, primary light control with reflector, of plastic, aluminium vaporised, primary optical cover: cover, of PMMA, transparent, light emission: direct distribution, primary light characteristic: asymmetric, installation type: post-top, for 1 x LED module colour temperature: 4000K, control gear: ECG Plus, control: power reduction, digital communication interface between ECG and LED module, overheat protection, flexible luminous flux parameterisation, time-dependent luminous flux control, constant luminous flux control, electronic power reduction, with terminal, 5-pole, max. 2.5mm², mains connection: 220..240V, AC, 50/60Hz, start of lifetime: 11 W, end of lifetime: 14 W, reduction: 6 W, luminaire housing, of diecast aluminium, powder-coated, Siteco metallic grey (DB 702S), length: 480 mm, width: 176 mm, height: 218mm, spigot size: d x l = 76 x 100mm (post-top) with reducer (accessory) 60 x 100mm, protection rating (complete): IP65, insulation class (complete): insulation class II (safety insulation), certification: CE, ENEC 10, VDE, standard-compliant lighting for roads and squares, packaging unit: 1 piece, factory setting: luminousflux part=100% (dimming level=254) Luminaire data Luminaire efficiency : 100% Luminaire efficacy : 94.55 lm/w Classification : A30 100.0% 0.0% CIE Flux Codes : 31 68 96 100 100 UGR 4H 8H (20%, 50%, 70%) C0 / C90 : 34.0 / <10.0 Control gear : ECG Plus System power : 11 W Length : 481 mm Width : 177 mm Height : 231 mm Equipped with Quantity : 1 Designation : LED 4000K / CRI >= 70 Power : 11W Colour : Luminous flux : 1040 lm Page 3/8

2.1 Description, Residential Road_S5 2.1.1 Floor plan [m] 7 2-3 -30-20 -10 0 10 20 30 40 50 60 [m] 1 : 1000 Road Road layout : without central reservation Width of roadway : 6.00 m No. of lanes : 2 Road surface category : R3 q0 : 0.08 Type of mast :Streetlight 10 micro LED (5XA5803K1B08) Luminaire placing : Right row photometric centre height.: 4.50 m Distance between masts : 32.00 m Kerb distance : 1.80 m Inclination : 0.00 Luminaire arrangement for: Streetlight 10 micro LED (5XA5803K1B08)Position Rotation x[m] y[m] z[m] Z[ ] C0[ ] C90[ ] 5XA5803K1B08 : 0.00 0.30 4.50 0 0 0 Border areas: => Page 4/8

2.1 Description, Residential Road_S5 2.1.1 Floor plan Border areas: sidewalk right (1) Road layout : General surface Width of roadway : 1.50 m No. of lanes : 1 Kerb distance : 0.00 m Page 5/8

2.1 Description, Residential Road_S5 2.1.2 3D view, View from the left Page 6/8

2.2 Summary, Residential Road_S5 2.2.1 Result overview, Road h b u Luminaire data Manufacturer : Order No. : Streetlight 10 micro LED (5XA5803K1B08) Luminaire name : Streetlight 10 micro LED (5XA5803K1B08) Equipment : 1 x LED 4000K / CRI >= 70 11W / 1040 lm Road layout : without central reservation Luminaire placing : Right row Width of roadway (b) : 6.00 m photometric centre height. (h) : 4.50 m No. of lanes : 2 Distance between masts (a) : 32.00 m Road surface category : R3 Kerb distance (u) : 1.80 m q0 : 0.08 Inclination (d) : 0.00 Right hand drivers Maintenance factor : 0.94 Horizontal illuminance E Average : 3 lx (S5 min. 3) Minimum : 0.6 lx (S5 min. 0.6) Page 7/8

2.3 Calculation results, Residential Road_S5 2.3.1 Table, Road (E horizontal) [m] 5.25 3.75 2.25 0.75 2 1.8 1.7 1.2 0.8 (0.6) 0.8 1.2 1.7 1.8 2 4.5 3.5 2.8 1.6 0.8 (0.6) 0.8 1.6 2.8 3.5 4.5 8.7 5.5 3.7 1.8 0.8 0.7 0.8 1.8 3.7 5.5 8.7 [10.4] 6.7 3.6 1.5 0.7 (0.6) 0.7 1.5 3.6 6.7 [10.4] 1.45 4.36 7.27 10.18 13.09 16.00 18.91 21.82 24.73 27.64 30.55 [m Illuminance [lx] Height of the reference plane : 0.00 m Average illuminance Eav : 3 lx Minimum illuminance Emin : 0.6 lx Maximum illuminance Emax : 10.4 lx Uniformity Uo min/average : 1 : 5.11 (0.2) Diversity Ud min/max : 1 : 17.9 (0.06) Page 8/8