NAVSEA STANDARD ITEM. 2.2 T9074-AS-GIB-010/271, Requirements for Nondestructive Testing Methods

Similar documents
Section GATE VALVES

DETAIL SPECIFICATION VALVES, ANGLE, PRESSURE RELIEF, NAVAL SHIPBOARD, FOR STEAM SERVICE

SECTION BUTTERFLY VALVES

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

Telefon (+45) Telefax (+45)

Team Insert Valve Sample Specification The Insert Valve shall conform to the following:

Leak testing of Valves. Standards for acceptable Rates of Valve Leakage

Propor tional Re lief Valve s

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

LARGE R/W GATE VALVES

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Engineering Data Sheet

Proportional Relief Valves

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

CLASS DH - PNEUMATIC TESTING - GREATER THAN 1 BAR (15 PSIG)

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

Types S100K and S102K Pressure Regulators

NAVSEA STANDARD ITEM. 1.1 Title: Authorization, Control, Isolation, Blanking, Tagging, and Cleanliness; accomplish

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Types 95L and 95H Pressure Regulators

INSTRUMENTATION VALVES

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

PIP PNE00012 Piping Examination and Leak Test Guide

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Type Testing of Rising Stem Valves Equipped with Graphite Packing for Fugitive Emissions

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Perform Pressure & Leak Test, Tubing & Piping. Module 12306

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

Instruction Manual Pressure Relief Valve and Rupture Disc Chlorine or Sulfur Dioxide, Series 869

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

TECHNICAL DATA. Page 1 of 12

Torque Specifications

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

INSTRUCTION MANUAL. Anchor Darling 800 Globe Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

2.2 S0600-AA-PRO-160/CH-16, Underwater Ship Husbandry Manual, Cofferdams

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

DETAIL SPECIFICATION VALVES, FILLER, LIQUID OXYGEN, AIRCRAFT TYPE

PRO-50 Instrument Supply Regulator

Model PIV UL/FM Post Indicator Valve. Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515

MEGR-1627 Instruction Manual

1805 Series Relief Valves

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

SECTION VALVES AND APPURTENANCES

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

World Area Differences Technical Information

BUTTERFLY VALVES Series 800

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

1200B2 Series Service Regulators. Instruction Manual

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

From: Commander, Carderock Division, Naval Surface Warfare Center, Philadelphia, PA To: Program Executive Officer, Ships (PMS 400D)

Type OS2 Slam-Shut Device

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

HYDROSTATIC LEAK TEST PROCEDURE

TECHNICAL DATA CAUTION

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

NOT MEASUREMENT SENSITIVE. MIL-DTL-2G 29 September 2006 SUPERSEDING MIL-DTL-2F 25 September 2002 DETAIL SPECIFICATION

64 Series Pressure Reducing Regulators

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

SPECIFICATIONS - DETAILED PROVISIONS Section Butterfly Valves C O N T E N T S

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

Product Bulletin No.: D99-RRV2015-PIB-001

FLANGED TWO-PIECE BALL VALVES

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Section: R100 Bulletin: R100.50A Date: 12/07 Supersedes: 08/06 THE STANDARD

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Date of Issue: July 2016 Affected Publication: API Specification 16C, Choke and Kill Equipment, Second Edition, March 2015 ADDENDUM 1

MSC Guidelines for Refrigeration Machinery

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

Atmospheric relief valve type 1100 Installation and maintenance instructions

1800C and 1800C-HC Series Service Regulators

Other Si min/max. Cr min/max. 0.4/ / / / Bal.

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

Pressure Regulator B-95

MODELS 1500, 1520, 1530, 1560

Models 1720A / 1760A

Types 749B and R130 Changeover Manifolds

OPERATING AND MAINTENANCE MANUAL

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

FLANGED TWO-PIECE BALL VALVES

NAVSEA STANDARD ITEM. 2.2 S0600-AA-PRO-160/CH-16, Underwater Ship Husbandry Manual, Cofferdams

Transcription:

NAVSEA STANDARD ITEM ITEM NO: 009-53 DATE: 29 JUL 2011 CATEGORY: II 1. SCOPE: 1.1 Title: Bolted Bonnet Steam Valve; repair (shop) 2. REFERENCES: 2.1 S9086-CJ-STM-010/CH-075, Fasteners 2.2 T9074-AS-GIB-010/271, Requirements for Nondestructive Testing Methods 2.3 MIL-STD-2035, Nondestructive Testing Acceptance Criteria 2.4 S9253-AD-MMM-010, Maintenance Manual for Valves, Traps, and Orifices (Non-Nuclear), User's Guide and General Information 2.5 S9086-RJ-STM-010/CH-504, Pressure, Temperature and Other Mechanical and Electromechanical Measuring Instruments 2.6 S9086-RK-STM-010/CH-505, Piping Systems 3. REQUIREMENTS: 3.1 Matchmark valve parts. (V) "INSPECT PARTS FOR DEFECTS" 3.2 Disassemble, clean internal and external surfaces free of foreign matter (including paint), and inspect parts for defects. 3.2.1 The removal of body-bound studs only to determine the condition of threads is not required. 3.2.1.1 Exposed portion of body-bound studs shall be inspected in accordance with Section 075-8.3 of 2.1. (I) or (V) TORQUE TEST (See 4.3) 3.2.2 Torque test each body-bound stud in accordance with Section 075-8.6.3.2(d) of 2.1. 1 of 5 ITEM NO: 009-53

(I) "LIQUID PENETRANT INSPECT" 3.2.3 Accomplish liquid penetrant inspection of seats (including back seat), discs, or gate in accordance with 2.2. 3.2.3.1 Acceptance criteria shall be in accordance with Paragraph 7 of 2.3, except hairline cracks in hard-faced areas of seats and discs or gate are acceptable provided the valve does not show evidence of leakage. 3.3 Repair valve as follows: 3.3.1 Straighten stem to within 0.002-inch total indicator reading. Polish stem to a 32 Root-Mean-Square finish in way of packing surface and remove raised edges and foreign matter. 3.3.2 Chase and tap exposed threaded areas. 3.3.3 Dress and true gasket mating surfaces. 3.3.4 Machine, grind, or lap and spot-in gate or discs to seats (including back seat) to obtain a 360-degree continuous contact. (I) or (V) "INSPECT CONTACT" (See 4.3) 3.3.4.1 Inspect contact using blueing method. 3.3.4.2 Transfer line for gate valve shall not exceed 3/16 inch in width and shall appear within the lower 75 percent of the gate seating surface. inch in width. 3.3.4.3 Transfer line for globe valve shall not exceed 1/16 (I)(G) "VERIFY LEVEL I PARTS AND CLEANLINESS" 3.4 Assemble valve, installing new gaskets in accordance with the manufacturer's specifications, installing new fasteners for those removed in 3.2, in accordance with Attachment A. 3.4.1 Install new valve stem packing conforming to MIL-P-24503/24583 combination in accordance with Chapter 6 of 2.4. 3.5 Hydrostatically test valve as follows: 3.5.1 Hydrostatic test equipment shall have the following capabilities: 3.5.1.1 Manual overpressure protection release valve. 2 of 5 ITEM NO: 009-53

3.5.1.2 Self-actuated and resetting relief valve with a set point no greater than 100 PSIG above the test pressure or 10 percent above the test pressure, whichever is less. (V) "GAGE CHECK" 3.5.1.3 Master and backup test gages with gage range and graduation in accordance with Table 504-6-1 of 2.5. The backup gage shall be cross-checked to the master hydrostatic test gage up to the maximum test pressure just prior to start of testing. Master and backup gages shall track within 2 percent of each other. 3.5.1.4 Protection equipment shall be accessible and test gages shall be located where clearly visible and readable to pump operator and inspector. (V)(G) or (I)(G) "SEAT TIGHTNESS" (See 4.4) 3.5.2 Test for seat tightness alternately on each side of gate for double seated valves, and on outboard side only on single seated valves, with the opposite side open for inspection. 3.5.2.1 Do not exceed handwheel closing force specified in Table 505-11-2 of 2.6. 3.5.2.2 Test shall be continued for a minimum of 3 minutes if there is no evidence of leakage, or in the event of visible leakage, until accurate determination of leakage can be made. Maximum allowable leakage: 10 cubic centimeters (cc) per hour, per inch of nominal pipe size; 10 cc maximum per hour for valve sizes less than 1-1/2 inches. (V)(G) or (I)(G) "SEAT TIGHTNESS" (See 4.4) 3.5.3 Test globe valve in the direction tending to open valve. 3.5.3.1 Do not exceed the handwheel closing force specified in Table 505-11-2 of 2.6. 3.5.3.2 Test shall be continued for a minimum of 3 minutes if there is no evidence of leakage, or in the event of visible leakage, until accurate determination of leakage can be made. Maximum allowable leakage: 10 cubic centimeters (cc) per hour, per inch of nominal pipe size; 10 cc maximum per hour for valve sizes less than 1-1/2 inches. (V)(G) or (I)(G) "BACK PRESSURE TEST" (See 4.4) 3.5.4 Back pressure test globe stop check valve with stem in the open position. Allowable leakage as follows: 3 of 5 ITEM NO: 009-53

VALVE SIZE (NOM) LEAKAGE RATE Up to 2 inches inclusive 25 cc/hr./in.dia. 2-1/2 inches - 10 inches inclusive 50 cc/hr./in.dia. Over 10 inches 100 cc/hr./in.dia. The back pressure applied shall be in accordance with the following: VALVE PRESSURE RATING TEST BACK PRESSURE 100 PSIG and Below 50 PSIG Over 150 PSIG 100 PSIG 4. NOTES: 4.1 The test pressures of 3.5.2 and 3.5.3 will be specified in Work Item. 4.2 Repair of valve operating gear will be specified in Work Item. 4.3 The paragraph referencing this note is considered an (I) if the valve is Level I. If the valve is not Level I, the paragraph is considered a (V). 4.4 The paragraph referencing this note is considered an (I)(G) if the valve is Level I. If the valve is not Level I, the paragraph is considered a (V)(G). 4.5 Test medium will be specified in Work Item. 4 of 5 ITEM NO: 009-53

ATTACHMENT A VALVE BODY MATERIAL 1/ Alloy Steel Carbon Steel Nonferrous 2/ 3/ Studs and Bolts to MIL-DTL-1222 Nuts to MIL-DTL-1222 Grade B-16 Grade B-16 Phosphor Bronze - Any Grade Silicon Bronze - Any Grade Nickel Copper - Class A 4/ Grade 4 or 7 Grade 4 or 7 Phosphor Bronze - Any Grade Silicon Bronze - Any Grade Nickel Copper - Class A or Class B 5/ Socket Head Cap Screws FF-S-86 FF-S-86 1/ Alloy steel is of Composition A - 2-1/4 percent Chromium, one percent Molybdenum, Composition B - 1-1/4 percent Chromium, 1/2 percent Molybdenum, and Composition C - Carbon Molybdenum. 2/ Nonferrous Alloy except Aluminum. 3/ Studs shall be Class 2 or 3 fit on the nut end and Class 5 fit on the stud and, except that a Class 3 fit with a thread locking compound may be used where temperatures do not exceed 250 degrees Fahrenheit. The thread locking compound shall conform to ASTM D 5363. Check Class 3 fit stud ends in accordance with SAE-J2270. 4/ Fasteners of Nickel Copper Aluminum shall be the only type used on sea chest and hull valves. 5/ Nuts of Nickel Copper Alloy, conforming to QQ-N-281 Class A or B, or Nickel Copper Aluminum conforming to QQ-N-286 shall be the only type used on sea chest and hull valves. 5 of 5 ITEM NO: 009-53