Transmitter CS 21 Operation Manual

Similar documents
Transmitter CS 21 Operation Manual

CC Operation Manual Oak Valley Drive, Suite 20, Ann Arbor, Michigan USA fax

Operation Manual. Transmitter IR 24. Models MWG 2491 / MWG Worldwide Supplier of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-DPX Operation Manual

RAM Operation Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Sensoric 4-20 ma Transmitter Board Operation Manual

High-performance submersible pressure transmitter For level measurement Model LH-10

RAM 4021 Operation Manual

High-performance submersible pressure transmitter For level measurement Model LH-10

MODEL GT820 OXYGEN SENSOR

O3 3E 1 F Gas Sensor Module

Instruction Manual Differential Pressure Transmitter

GasSense NDIR User Manual

Operation Manual. Rev. C LPT Low Power Transmitter (Electrochemical Sensor)

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

210 Series Transmitter with External Electrochemical Sensor

Electro-Pneumatic Converter YT-940 SERIES

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Operating Instructions

Instruction and Maintenance Manual

INSTALLATION & MAINTENANCE INSTRUCTIONS

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Installation, operating and maintenance Instructions for Seemag bypass level indicator

SANP ACTING RELAYS YT-520/525/530 SERIES

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Model PDT Dewpoint Transmitter

Pressure Measurement Single-range transmitters for general applications

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

RGC-IR Remote Gas Calibrator for IR400

Visualize Nitrogen Gas Consumption

Instruction and Maintenance Manual

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

Instruction Manual Contact Pressure Vacuum Gauge

ZIRCONIA OXYGEN DETECTOR SERVICE MANUAL

with O 2 Controller Instruction Manual

Preferred Instruments Danbury, CT USA

Evaporative Emissions (EVAP) system, checking

FLAMMABLE GAS SENSOR/TRANSMITTER

Operating Instructions Temperature Measuring System MF420-5T-100

OXY 3690 MP. Measuring transducer for air oxygen

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Climatic Independent Level Sensor LAR

Electronic gas volume corrector model DGVC-04

444C DUAL PERFORMANCE VALUE PACK

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

User Manual. PolyGard AT-1130 V3. Electrochemical Nitrogen Dioxide Transmitter. July, 2011

Technical Data Sheet MF010-O-LC

400C & 450C DUAL PERFORMANCE VALUE PACKS

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Best Practice Guide, Servomex 2700

Installation and Operation Manual

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev

AMS 2710 PCB pressure sensor module with V output

200 PSI COMPRESSORS - MODEL NUMBERS

Malema Sensors M-2700 Integrated Ultrasonic Flow Meter

CSA Sample Draw Aspirator Adapter Operator s Manual

EPP4 Pressure Regulator Basic G 1/4"

Model 130M Pneumatic Controller

A17W49_MASEM_F_EN MANUAL

MANUAL KPS Pressure Control Valve

IMPORTANT SAFETY INSTRUCTIONS

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Operating Manual VSA100A. tina29e1 ( )

FTC130 Transmitter. Operating Manual

dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Columbus Instruments

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

GEMS SENSORS & CONTROLS

! Warning, refer to accompanying documents.

Operation and Maintenance Manual

Operating Instructions Part No

SDX Submersible Depth Transmitter User Manual

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Relative Pressure Sensor for Automobile Fuel Tanks

Gas density monitor With integrated transmitter Model GDM-100-TI

100C Air Compressor Kit

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Datasheet: K-30 ASCII Sensor

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

RK LEL Sample Draw Aspirator Adapter Operator s Manual

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

User Manual. µ-gard MD Electrochemical Carbon Monoxide Transmitter Serial No. MD April, 2011

Instruction Manual Differential Pressure Transmitter

Transcription:

Transmitter CS 21 Operation Manual 1194 Oak Valley Drive, Suite 20, Ann Arbor, MI 48108 800-959-0573 734-769-1888

Content Page For your Safety 3 General Description 3 Detection Principle 4 Operation 4 Design 4 Mounting 5 Electrical Connections 6 Start-up 7 Check of Electrical Zero Point 7 Check Dead Band (Should not be adjusted without GfG Authorization) 7 Check Sensitivity (Calibration) / Bump Test 8 Service 9 Maintenance and Inspection 9 Trouble Shooting 9 Accessories 9 Connection Diagram CS21 / Built-in Sensor 10 Connection Diagram CS21 / External Sensor 11 Technical Data 12

T Y P E L ABE L I N S I D E ME NU C H A N N E L O N F A U L T % For your Safety As with any piece of complex equipment, the GfG CS21 transmitter will do the job it is designed to do only if it is used and serviced in accordance with the manufacturer's instructions. Please protect yourself and your employees by following the instructions in this manual. All individuals who have or will have the responsibility for using and servicing this product must carefully read this manual. The warranties made by GfG with respect to the product are voided if functions or parameters are changed without the permission of GfG. They are also voided if the product is not used and serviced in accordance with the instructions in this manual. Failures or false alarms caused by interfering gases or electrical signals are not part of the warranty obligation. The above does not alter any statements by GfG regarding warranties, conditions of sale and/or delivery. General Description A fixed gas monitoring system consists of a transmitter and a control module, which are connected by means of a transmitter cable. The transmitter converts the gas concentration into an electrical signal, which is sent to the control module for evaluation. Fixed Gas Monitoring System A 3 ou N A3 nm A2 A1 U 100 80 60 40 20 A 2 A 1 F A ULT U TEST MENU QU T MENU Detection Evaluation Warning Fig. 1 The CS21 is an "intelligent" transmitter. Its comprehensive electronic circuitry allows easy handling and servicing and increases the measurement reliability and accuracy. The CS21 is characterized by following features: Easy calibration at site. Long sensor life. 3

Detection Principle The CS21 is operated on the chemosorption principle. The basic element is a sensor, which is different depending on the application and the gas to be monitored. As long as there is no gas in the ambient air, the internal resistance of the sensor is rather high. As soon as gas is adsorbed at the sensor surface, the internal resistance is reduced. The change in resistance is the measure for the gas concentration and is converted to a standardized current signal (0.2.. 1 ma or 4.. 20 ma) by the integrated electronic circuit. The chemosorption principle has proven long-term stability. Operation The CS21 passes function and performance tests before shipment and is calibrated with suitable test gases. This does not preempt the user s obligation to perform a function test after putting the transmitter in operation. Design The design of the CS21 is shown in Fig. 2. The sensor is mounted in the sensor support (pos. 5). Gas enters the sensor chamber through the diffusion inlet (pos. 6). The casing (pos. 2) includes a resin encapsulated p.c. board with electronic components. The electronics convert the measurement signal into the output of 0.2.. 1 ma or 4.. 20 ma, which is transferred to the controller by a cable. CS21 Design 1. Casing top 2. Casing bottom 3. Type label 4. EMC cable gland (PG 11) 5. Sensor support 6. Diffusion inlet Fig. 2 4

Poti N CS21 Schematic Poti 0 (option) Poti C Test Contacts Resin Fuse 1 2 3 6 5 4 Terminals EMC cable gland-pg 11 Sensor Fig. 3 Mounting It is essential to ambient conditions before deciding on the mounting position. To achieve representative measurement results, check the: the room ventilation and the gas density, the danger highlights. Install the CS21 in a place where the gases will pass the sensor even in case of bad ventilation. If necessary, use a smoke cartridge to check air flow. Take the following into consideration as well: Ambient temperature, Rain, hose water, dripping water, condensate and Dust in the atmosphere Other possible contaminants The CS21 is to protected to a great extent against water and dust (IP 54). Special accessories are available to provide additional protection for very harsh conditions. Please contact GfG for detailed information.! The warranty may be voided, if the transmitter is exposed to ambient conditions that were unknown to GfG during planning, production or delivery. When deciding on the transmitter position, make sure it is always accessible for service and maintenance. Mounting the CS 21 with the sensor facing the floor is recommended. A different mounting position, however, does not affect the sensor accuracy. 5

For connecting the CS 21 refer to the connection diagram (also refer to the terminal diagram of your GMA controller). To mount the transmitter, remove the four lock screws and lift the casing top off. Attach the casing by putting two screws through the appropriate borings. The optional potentiometer N is factory-set and MUST NOT be turned.! The CS21 is not certified for use in hazardous areas. Electrical Connections An electrician following the applicable regulations should install cable and electrical connections. A shielded 18/3 cable should be used (Belden #8770 or equivalent) for distances less than 500 yards. Connections Terminals Resin Terminals Resin 0 1 2 3 6 5 4 red red Sensor green yellow Signall Ground Voltage Supply EMC-PG 11 0 1 2 3 6 5 4 green brown white blue Sensor Signall Ground Voltage Supply EMC-PG 11 Sensor Connecting Wire, max. 2 m External Sensor Fig. 4 The supply voltage for the transmitter (terminal 4) is 10.. 30 V DC. Once the installation is completed, close the casing top and fix it with the screws. Note: Shielding is done over the EMC cable screwing. 6

Transmitter Casing S h ie ld T ransm itter Cable EMC Screwing The shield is to be connected to the transm itter casing by m eans of the cable screwing. Fix the shield as shown in above sketch. Fig. 5 Start-up Once the CS 21 is installed, the user can put it into operation. Before shipment, the CS 21 is calibrated and tested after a specific warm-up time. When connecting the transmitter to a controller (power supply) you should allow approximately 60 minutes to warm-up the chemosorption sensor before checking the sensitivity. Should you notice that a recalibration is required, allow an extended warm up period of about 4 hours. The CS 21 is calibrated and tested before shipment. Certain deviations, however, are possible due to transport, mounting, and ambient conditions. Inside the CS 21 there are two test contacts to check the electrical output signal (fig. 3). The voltage at the test contacts can be measured with a voltmeter. Warm-up time is approximately 60 minutes. Terminals Poti N Poti 0 (option) Poti C 1 2 3 6 5 4 Test Contacts Resin Fuse EMC cable gland-pg 11 Figure 3 Sensor Check of Electrical Zero Point 1) Use a multimeter to check the output signal by measuring the voltage at the test contacts. 2) The reading should be approximately 0.197 V. 3) If there is a deviation from this range it is possible to adjust the value by turning pot 0. Pot 0 0 1 2 3 6 5 4 Test Contacts 0.197 V Sensor Check Dead Band (Should not be adjusted without GfG Authorization) 1) Use a multimeter to check the output signal by Pot N measuring the voltage at the test contacts. 2) After the warm-up time of approximately 30 minutes, + 0 the signal should be approximately 0.200 V for zero - gas*. 3) In case of a deviation it is possible to adjust the value by turning potentiometer N. 0 1 2 3 6 5 4 Test Contacts 0.200 V * In this case, gas is not fresh air but test gas specified gas to be monitored Sensor 7

Check Sensitivity (Calibration) / Bump Test 1) Use a multimeter to check the output signal by measuring the voltage at the test contacts. 2) Attach the calibration adapter to the diffusion inlet of the transmitter. Moisten and wring out the humidifier sponge, install the sponge in the humidifier and attach to the calibration adapter. 3) Select a suitable test gas, taking into consideration which gas has been used for initial calibration (found on the test report). Gas concentration should be at least 20% above the second alarm threshold (for bump testing). 4) The reading should be in the 10% range for 4.. 20 ma interface. 5) In case of a deviation you can correct the value by turning potentiometer C. + 0 - Sensor Pot C 0 1 2 3 6 5 4 Test Contacts 1.00 V When using a GMA controller, signal checks and adjustments should be done at the GMA (please refer to the GMA manual).! Do not use a test gas with a balance of nitrogen You must use an inline humidifier, and a ½ l/min. valve with test gas. For measurement accuracy it is important to use the end range gas to calibrate the CS 21. Adhere to the following procedure for checking the sensitivity: Suppress alarm transmission. Put calibration adapter on transmitter. Supply test gas to CS21 without pressure and with a flow rate of approx. 0.5 l/min. Within about 2-5 minutes a voltage corresponding to the gas concentration can be measured at the test contacts. Alternatively the calibration can be checked at the GMA controller. Is the measured value equivalent to the calibration curve? yes no Re-adjust calibration by turning potentiometer C. Alternatively: Re-adjust calibration point at GMA controller. Please refer to the operation manual of your GMA controller. Disconnect test gas and calibration adapter. Disconnect alarm suppression. 8

Service Service includes maintenance, inspection, and repair of gas warning equipment and function tests of the equipment. A function test checks the: Zero point and sensitivity (calibration) Alarm with gas concentration Response time Gas sampling and gas processing system (if any) Alarm signal activation Failure alarm The function check should be done before putting the system into operation, and it should be repeated at least once a year. For service, please contact: Phone: (734) 761-5987 Fax: (734) 769-1888 E-mail: info@gfg-inc.com Website: www.gfg-inc.com Maintenance and Inspection With maintenance and inspection you can ensure the proper working status of the gas detection system. The CS 21 does not require special maintenance. Depending on the ambient conditions, gas detection systems may change their behavior. Therefore, it is important to perform a visual check every day, particularly during the first few days after starting up the device: Check gas processing system and filters (if any). Check gas supply for blockage (for correct measurement the gas supply to the sensor must not be blocked). Sensors are subject to ageing and exhausting. Depending on their type and on their exposure to gas they can be used up. A sensitivity check can only be done with a suitable test gas after certain periods of time. The sensitivity calibration is an expert calibration and is usually performed by GfG service or by authorized technicians. Trouble Shooting Failure Reason Solution Zero point cannot be adjusted Faulty sensor Replace sensor Full scale value cannot be set Faulty sensor Replace sensor Output current has fallen to 0 ma Defective fuse Faulty sensor Cable cut Replace fuse Replace sensor Re-fix connection Accessories Part No. Screw-on calibration adapter 2000209 9

Connection Diagram CS21 / Built-in Sensor Built-in Sensor MK red green yellow white green brown 1 2 3 6 5 4 Connect shield to Cable Gland Signal GND 20V / 24V GMA 300 2 1 5 GMA 011 2 1 5 GMA 100 2 1 5 Motherboard from 1997 (blue) GMA 100 2 0 3 Motherboard until 1996 (no color) GMA101 2 1 5 GMA41 30 29 28 GMA81 (A) 3 2 1 10

Connection Diagram CS21 / External Sensor MK External Sensor brown green white white green brown 1 2 3 6 5 4 Connect shield to Cable Gland Signal GND 20V / 24V GMA 300 2 1 5 GMA 011 2 1 5 GMA 100 2 1 5 Motherboard from 1997 (blue) GMA 100 2 0 3 Motherboard until 1996 (no color) GMA101 2 1 5 GMA41 30 29 28 GMA81 (A) 3 2 1 11

Technical Data Transmitter CS21 Type: CS21 Sensor Type (MK): see test report Gas: See test report Range: see test report Gas Supply: Diffusion Detection Principle: Chemosorption (CS) Supply Voltage: 10.. 30 V DC Output Current: 0.2.. 1mA (4kΩ) or 4..20mA (200Ω) Response Time t A : < 14 s (depending on gas) Typical Sensor Life: > 5 years Climate Conditions Operational Temperature: - 30.. + 55 C Humidity: 20.. 96 % r. h., non condensing Atm. Pressure: 920.. 1100 hpa Casing Material: Aluminum Protection: IP 54 Cable Gland: PG 11 screwing, max. cross section 3 x 1.5 mm2 Transmitter Cable: Shielded cable - #18/3 shielded or Belden 8770 equal Dimensions: 100 x 100 x 57 mm (WxHxD) Weight: approx. 370 g 12

1194 Oak Valley Drive, Suite 20 Ann Arbor, Michigan 48108 USA Phone: (800) 959-0329 or (734) 769-0573 Fax (734) 769-1888 E-mail: info@gfg-inc.com Website: www.gfg-inc.com GfG reserves the right to change part numbers, prices, and/or technical information without notification. Rev. 2 7004-CS21 042308