INFLATOR TDUX-IT-16 AND GAS CYLINDER E

Similar documents
TDUX Inflatable Duct Sealing System 1.0 General Product Information

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

OPERATING INSTRUCTIONS

MUELLER GAS. No-Blo Operations Using D-5. Drilling Machine. Reliable Connections. General Information 2

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

INSTRUCTION MANUAL. January 23, 2003, Revision 0

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE. MODEL TB3/0.1mm

Flexi-pro Aerosol Delivery System (FADS) Manual

SIMPLAIR PIPING TOOL. JXT Company

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

VERSA BIKE RACK INSTRUCTIONS

HYQUEST SOLUTIONS PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB6

64 Series Pressure Reducing Regulators

Installation Instructions

INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

Types 749B and R130 Changeover Manifolds

Installation, Operation, and Maintenance Manual

1305 Series Pressure Reducing Regulators

Electron Microscopy Sciences

1200B2 Series Service Regulators. Instruction Manual

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

MyControl Bathing System Signature Series

Vibration isolation system 1VIS10W. User manual

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

POOL ROVER ST POOL CLEANER Installation Instructions

Hydraulic Punch Drivers

Model 130M Pneumatic Controller

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Rapidmain Installation Guide

DBML-60/80 Squeeze Tool

Final Assembly Instructions Bikes with Quill Stems

RB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

SINORIX Valve Reconditioning

Halsey Taylor Owners Manual STOP!

HD Mast Series. Installation & Operation Manual

Operation and Maintenance Instructions

Instruction Manual. B&O WITH SLOPE BACK TENDER Live Steam

INSTALLATION INSTRUCTIONS

FX IMPACT OWNER S MANUAL

Float Operated Level Controllers

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

BOYLE S / CHARLES LAW APPARATUS - 1m long

Supplementary Operation, Assembly, Maintenance Manual for F3-42 model and optional attachments

GAS STRUT SAFETY INFORMATION

Type BBS-03, BBS-05, BBS-06, BBS-25

MAINTENANCE PROCEDURE FOR X 650

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

Fit Testing. C50 APR New Equipment Training Module March 2010 Rev01

Final Assembly Instructions Bikes with Threaded Headsets

1805 Series Relief Valves

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

INSTALLATION & MAINTENANCE INSTRUCTION

PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included)

OPERATING AND MAINTENANCE MANUAL

HORNE 20 THERMOSTATIC MIXING VALVE TYPE H-2003

TOOL BOX 033- HOSEREEL SERVICE / FAULT FINDING

1800C and 1800C-HC Series Service Regulators

CO2 Tank Conversion Kit P.N , P.N , and P.N

Installation, Operation, and Maintenance Manual

Installation Instructions and valve Maintenance Rev. 0 of 29/09/15

Halsey Taylor Owners Manual

Bedienungsanleitung / Operating Instructions / Instrucciones de uso / Mode d emploi / Istruzioni d'uso

BMW Motorrad. Installation Instructions. BMW Motorrad Communications System for Schuberth C3

Operation Manual. PEGAS NovoTap, PEGAS NovoTap+

Model 106 DPI "Micro-switch" Installation and Operating Instructions

15000 Series Exhausting Arm - Wall Mount Models: 15076/15106/15146

Tri-Tech Medical Inc.

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

BR 27g. Operating, assembly and maintenance instructions for discontinuous sampling valve. 1. Design, operation and dimensions:

Regulator from 1800 B series

Bulletin /06/2012 Supersedes 10/23/00. Installation of John Crane Type 73 Inflatable Mechanical Seal. Page 01 of 10

Installation and Maintenance Instruction Manual

Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

REVERSE OSMOSIS INSTALLATION Watermark 4 Stage

DS06D,G Dial Set Pressure Regulating Valve

Techcon Systems TS1258 Pressure Pot

ACCUCRAFT UK LTD Unit 4, Long Meadow Industrial Estate, Pontrilas, Herefordshire. HR2 0UA Tel:

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

5 Gallon EVkeg Operation Manual

2.0 INSTALLATION & SERVICE

Budget Range Operators Handbook

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING!

ASSEMBLY INSTRUCTIONS

GILMONT ACCUCAL FLOWMETERS

WEBLEY Please read this manual before using your airgun

Transcription:

INFLATOR TDUX-IT-16 AND GAS CYLINDER E7512-0160 Operating manual Inflator TDUX-IT-16 together with the special gas cylinder E7512-0160 is specifically designed for inflating TDUX duct seals. The inflator and cylinder are not to be used for any other purpose Manufactured for CommScope by ISI Metallwarenfabrik Ges. m.b.h. A-1217 Wien, Kürschnergasse 4

Contents Section 1 Description of equipment 3 Section 2 Safety and good practice 4 Section 3 Operating instructions 5 Section 4 Trouble shooting 7 Section 5 Performance data 9 Section 6 Replacement parts 10 2

Section 1 - Description of equipment The equipment has 7 main sections. The numbers in brackets refer to the drawing on the back side of this manual.. 1.1 Gas cylinder holder (1). Material - High performance plastic. The plastic material thermally insulates the operator from the surface of the gas cylinder which cools rapidly during discharge. 1.2 Basic regulator (2) with ON/OFF control lever (3). Material - Anodised aluminium body with metal, plastic and rubber components. The regulator ensures that the pressure of the gas entering the flow controller (4) is maintained at the correct level. 1.3 Flow controller (4) with non-return valve (not shown on drawing) connects the basic regulator (2) to the pressure controller (5). Material - Anodised aluminium body with metal, plastic and rubber components. The device controls the flow rate of the gas entering the pressure controller (5) so as to achieve filling within the specified time limits. 1.4 Pressure controller (5) incorporating a relief valve (not shown on drawing) and with a pressure gauge (6). Material - Anodised aluminium body with metal, plastic and rubber components. Pressure gauge body - plastic with rubber shock resistant cover. This device ensures that the pressure in the TDUX duct seal on completion of filling is within the specified limits at all temperatures within the specified range. The pressure gauge pointer moves around when filling is taking place, approximately 30 seconds at normal temperatures, and stops within the green sector when filling is complete. Failure of the pointer to reach the green sector serves as an indicator that the gas cylinder needs replacing. This whole section is pivotally mounted on the flow controller and may be freely rotated in either direction to enable the operator to face the pressure gauge to suit himself. 1.5 Delivery pipe (7). Material - Polyurethane tubing. This flexible delivery pipe enables the operator to work in confined or awkward situations. 1.6 Tube-snap assembly (9). Material - Brass and nickel plated brass This device enables the TDUX filling tube (12) to be securely held, gas tight, without restricting the flow of gas. The tube is firmly held to enable it to be removed from the TDUX duct seal on completion of filling. 1.7 Gas cylinder E7512-0160 (8). Material - Steel cylinder filled with carbon dioxide under pressure. The gas cylinder contains a minimum of 15 grams of CO2. The gas is sealed in the cylinder by a special valve incorporated in the cylinder neck. This valve is only opened when the cylinder is connected to the inflator. 3

Section 2 - Safety and good practice 2.1 Gas cylinder - E7512-0160 SAFETY The gas pressure in the cylinder is approx. 60 Bar (900 lbf/in 2 ) at room temperature. MAX. OPERATIONAL TEMPERATURE 50 C KEEP COOL AND DRY USE ONLY AS INSTRUCTED MISUSE CAN BE DANGEROUS DO NOT HANDLE THE CYLINDER WITH UNPROTECTED HANDS IMMEDIATELY AFTER FILLING A TDUX DUCT SEAL IN COLD WEATHER - FROSTBITE CAN RESULT. Good practice I Cylinder E7512-0160 should only be used with inflator TDUX-IT-16. II To check if a gas cylinder is empty, shake the cylinder. If a rattle is heard the cylinder is empty or has been previously used. III IV Always wipe the cylinder clean, particularly the neck and sealing stem. Check if the cylinder sealing stem is not distorted, bent or damaged, before inserting it into the inflator. In cold weather, before each inflation, warm the cylinder in the gloved hand only. 2.2 Inflator TDUX-IT-16 SAFETY I II USE ONLY AS INSTRUCTED Do not attempt to make adjustments to the regulator, controller or relief valve. These have been correctly set at our factory. Good practice I When removing or replacing a gas cylinder (8) put the ON/OFF lever (3) in the OFF position. Failure to do this will, however, not impair function. II III IV V VI Always replace the gas cylinder holder (1) when the inflator is not in use. Do not store for extended periods with a gas cylinder (8) installed in the inflator. Do not knock, drop or otherwise maltreat the inflator, taking particular care of the pressure gauge which is a sensitive instrument. During inflation hold the inflator so that the gas cylinder is between vertical and horizontal, neck uppermost. Do not operate the inflator with the gas cylinder pointing downwards. When removing the TDUX filling tube (12) from the tube snap assembly (9), unscrew the clamping screw (10) just sufficiently to release the tube - generally 1/2 a turn. Do not completely open the clamping screw (10) as this may allow the sealing O -Ring (11) to fall out. 4

Section 3 - Operating instructions 3.1 Getting ready I Check ON/OFF lever (3) is in the OFF position. II Unscrew and remove gas cylinder holder (1). III Insert cylinder (8) neck uppermost, into gas cylinder holder (1). IV Screw gas cylinder holder (1), hand tight, on to the inflator. 3.2 Inflator checking procedure (to be carried out at the commencement of each filling session or every 50 or so TDUX duct seal fillings). I II III IV V VI VII VIII IX Observe the pointer on the pressure gauge (6). This should be resting on the low stop-peg. If the pointer is clear of the stop-peg, the gauge must be replaced (see section 6 - replacement parts). Confirm that a used TDUX filling tube (12) is attached to tube-snap assembly (9) and the clamping screw (10) is tight. If not, insert a sealing bag inlet tube as described in steps 3.3. (I) - 3.3. (III) below. Fold the TDUX filling tube (12) over itself (to close off the tube and prevent gas from escaping) and press the fold tightly between finger and thumb, or use a pair of pliers to close the tube. Rotate the pressure controller housing (5), if necessary, so that the pressure gauge dial is clearly visible. Push the ON/OFF lever to the ON position. The pointer on the pressure gauge (6) will move round the dial. When it reaches the green sector push the ON/OFF lever (3) to the OFF position. The pointer should remain in the green sector indicating the inflator is working satisfactorily. If the pointer fails to reach the green sector, push the ON/OFF lever (3) to the OFF position, replace the gas cylinder (8) and repeat the procedure. If the pointer reaches the green sector, but drops back when the lever is pushed to the OFF position, check the TDUX filling tube connections at the tube-snap assembly for leaks, refold the TDUX filing tube more securely and repeat the procedure. Unscrew clamping screw (10) 1/2 turn only and remove used TDUX filling tube. 5

3.3 Inflation of TDUX duct seal With the TDUX duct seal already in place and the last used TDUX filling tube attached to the inflator. I II III IV V VI VII VIII IX Unscrew clamping screw (10) 1/2 turn only and remove filling tube. Insert filling tube (12) (of the TDUX duct seal to be filled) into forward opening in tube-snap assembly (9) as far as it will go. Note: a slight resistance will be felt as the tube pushes through the seal (11). Tighten the clamping screw (10), finger tight only. Push the ON/OFF lever (3) to the ON. It will stay in this position. Filling of the TDUX duct seal now starts. Observe the pressure gauge (6). During filling, the pointer will gradually move round the dial until it reaches the green sector when filling is complete. Leave inflator in ON position for a further 30 seconds. Push the ON/OFF lever (3) to the OFF position. Observe the pressure gauge pointer for a further few seconds. This will remain stationary within the green sector indicating no gas loss from the TDUX duct seal and inflator system. Remove the TDUX filling tube (12) from the TDUX seal by holding the tube-snap assembly (9) and pulling firmly. Leave the TDUX filling tube (12) attached to the tube-snap assembly (9). If the checking procedure is to be carried out, proceed to step 3.2. (I). If the next TDUX duct seal is to be filled return to step 3.3. (I) above. If no further TDUX duct seals are to be immediately filled, leave the filling tube attached to the inflator, andstore away safely. 6

Section 4 - Trouble shooting In each case, carry out the checks given. If, on completion of the checks, the fault still persists, and is not cured by replacement of the tube-snap assembly, see section (III) (c) below; or delivery pipe, see section (III) (d) below; or pressure gauge, see section (VI) (a) below; return the inflator to CommScope. (I) Problem Cannot engage threads on gas cylinder holder with threads on inflator. Check (a) Gas cylinder (8) is inserted into cylinder holder (1), neck upper most. (b) No debris is in the bottom of the cylinder holder. (II) Problem When cylinder is inserted correctly and holder screwed on to inflator sound of escaping gas is heard. Check (a) ON/OFF lever (3) is in OFF position. (b) Cylinder holder (1) is screwed firmly on to the inflator. (c) Remove cylinder holder (1) and cylinder (8) and check if cylinder sealing stem is not damaged or bent. (d) If checks (a) - (c) OK, discard cylinder (8) and try again with a fresh cylinder, making sure to wipe clean the neck and sealing stem. (III) Problem When connected to the TDUX duct seal and the ON/OFF lever (3) is put in the ON position, sound of escaping gas is heard. Check (with ON/OFF lever in OFF position) (a) TDUX filling tube (12) is correctly fitted to the tube-snap assembly (9) and clamping screw (10) is tight. (b) Remove TDUX filling tube (12) and check that surface of the tube which enters the clamping device is not damaged, distorted or scored. If this is so, cut off the damaged length with a sharp knife, so that the cut end face is approximately square (but not more than 45 to the plane of the diameter). (c) If on completion of checks (a) - (b) above, the sound of escaping gas is heard at the tube-snap assembly (9), fit new tube-snap assembly to the delivery pipe (7). (d) Check that locking nuts at both ends of delivery pipe are tight and delivery pipe is undamaged. If damaged, fit new delivery pipe. 7

(IV) Problem When connected to the TDUX duct seal and the ON/OFF lever (3) is in the ON position, the pointer on the pressure gauge (6) moves to the green sector, but the TDUX duct seal does not inflate, or inflates very slowly. Check (with ON/OFF lever (3) in OFF position) (a) TDUX filling tube (12) is not closed off along its length due to sharp kinks or flattening. (b) Remove TDUX filling tube (12) from clamping device (9) and check if entry diameter is clear. Before replacing the TDUX filling tube (12), briefly put the ON/OFF lever (3) to ON position to clear any obstruction. (V) Problem Pointer on pressure gauge does not reach green sector when filling the sealing bag. Check (with ON/OFF lever (3) in the OFF position) (a) Remove gas cylinder (8) and shake it. If a rattle is heard, the cylinder is not full or empty. Replace with fresh gas cylinder. (b) In freezing weather, it may be necessary to warm the gas cylinder in a gloved hand after each filling. CAUTION When filling the TDUX duct seal, the temperature of gas cylinder falls considerably. In very cold weather, the surface temperature after filling can be low enough to cause frostbite if handled without gloves. (VI) Problem Pointer on pressure gauge goes past the green sector when filling the sealing bag. Check (with the ON/OFF lever (3) in OFF position) (a) Unscrew the clamping screw (10) 1/2 turn only and remove the TDUX filling tube from the tubesnap assembly (9). Check that the pointer on the pressure gauge (6) rests on the low stop peg. If not, fit new pressure gauge. 8

Section 5 - Performance data Time to inflate 700 ml TDUX at room temperature 40-60 seconds TDUX pressure on completion of filling 2.8-3.2 bar (40-46,5 lbf/in 2 ) Working temperature -5 C to 30 C (23 F to 86 F) Recommended interval between successive fillings Minimum net CO 2 weight in E7512-0160 gas cylinder 2 minutes at normal temperature (in cold weather, this interval will be considerably longer) 15 g Weight of carbon dioxide gas per filling 5 g approximately Number of bags filled per E7512-0160 gas cylinder 3 approximately Relief valve opens at 3.2 + 0,2/-0 bar (46,5-48,5 lbf/in 2 ) Pressure gauge accuracy 1.6 % of full scale deflection Weight of inflator TDUX-IT-16 complete with gas cylinder E7512-0160 400 g approximately 9

Section 6 - Replacement parts Please refer to the drawing on the back side of this manual. The following replacement parts are available. Gas cylinder holder (8) E7512-0200 Tube-snap assembly (9) E7512-0220 Pressure gauge assembly (6) E7512-0240 Delivery pipe (7) E7512-0260 Sealing o ring (11) E7000-1131 (R222) 10

- - E7000-1131 ( o ring: R222) - - 1993 11

1993 CommScope Connectivity Belgium bvba Diestsesteenweg 692 B-3010 Kessel-Lo, Belgium Tel.: 32-16-351 011 Fax: 32-16-351 697 commscope.com Visit our website or contact your local CommScope representative for more information. 2016 CommScope, Inc. All rights reserved. TDUX and all trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. TC 314/OM/2 10/96