Compact Manometer. Pressure measurements can easily be taken any time, anywhere.

Similar documents
Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Pilot Check Valve: Metal Body Type

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Standard Specifications. Fluid Proof pressure Maximum operating pressure. Regulating pressure range

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Standard style

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Specifications. JIS Symbol 2 port valve 3 port valve (A) 2 (A) 2. Construction. 2 port valve/series VHK2 3 port valve/series VHK3.

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

Regulator/Modular Style AR1000 to 6000

Clean Speed Controller with One-touch Fitting

Precision Regulator. Series Model Regulating pressure range Port size Page

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

Mod. M M M063..

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

Series IRV1000/2000/3000

Direct Operated Precision Regulator Modular Style. Standard Specifications

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Series AMJ. Drain Separator for Vacuum

How to Order. Rc NPT 1/8 1/4 3/8 1/2

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

The plastic bowl guard does not corrode. The draining method is selectable between the push type and the auto drain type.

Multistage Ejector Series ZL

Multistage Ejector Series ZL

VACUUM REGULATORS CONTENTS

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV

Connection Thread M, R(PT), Rc(PT) How to Order. Applicable tube O.D. Thread. 8 ø8. ø10. ø12. ø16. Tube (Rod)

IR1000-A IR1010-A IR1020-A

How to Order. Applicable tube O.D. Thread. 8 ø8. ø10. ø12. ø16. Tube (Rod) Straight union. T Different dia. straight. F Female connector TX Male elbow

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Compact Pressure Switch

reduces flow setting time and setting errors!

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure

(1) Type (2) Tube dia. (ød(1)) (3) Thread size (T) (4) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Coiling Tube with Twist-Proof Fitting

Modular Type Regulators

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Brass One-touch Fittings

Series KJ. Miniature One-touch Fittings. Applicable Tube

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

Compact Pressure Switch

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Digital pressure gauge Model CPG500

(1) (2) (3) (4) No indicator type Digital pressure sensor with large display 30mm negative pressure gauge Air

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Digital Flow Switch. Series PFM7

Series ZL. Multistage Ejector. New models! ZL212 large flow rate type and ZL112 with valve. ZX ZR ZM ZY ZH ZU ZL ZF ZP ZCU

Related Products: Auto Drain Valve. Model/Specifications. Model

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

Propane Conversion Kit Instructions

Low torque Metal seal type Rotary joint

Hand-held pressure calibrator with integrated pump Model CPH6600

Recommended applicable tubing. Specifications. Operating vacuum pressure. 20 C to 80 C Threads. Principal parts material

3/8" Dr. Air Butterfly Impact Wrench

PVC Quick Drain Valve

(1) Union Filter for positive and negative pressure (2) Filter size. (3) Tube dia. (4) Holder option : without Holder : with Holder

1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.

(2) Effective sectional area (no code for mini type) (3) Intake-side shape (no code for mini type) : Quick-fitting joint type : Taper pipe thread type

Instruction Manual EMA 84 Digital Pressure Gauge

SSL. Smart Valve Positioner.

AS13 1F-M3 AS13 1F-M5 AS23 1F-01 AS23 1F-02

Operation Manual Air Saver Unit ASV5000 Series

Push-In Fitting Type Pressure Gauge

One-touch Fittings Manifold. Porting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting.

PTG100 Precision Test Gauge

DPS-400 SERIES DPH-100 SERIES

[Instruments for vacuum measurement, checking and adjustment] 3

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Push-In Fitting Type with Stop Valve

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

159 mm 154 mm. Subject to changes 10/2012

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Instructions for High Altitude Conversion

Pressure Automated Calibration Equipment

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Push-In Fitting Type Silencer

The products listed in this page are ECO-friendly products. * Please refer to page 4 for the details of ECO-friendly products. Model UAMR AD- L

Vacuum Pad with Ejector. Series ZHP

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

C 0G 00 N/US

2-Color Display Digital Flow Switch

Thin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1.

F l o w c o n T R o l v a l v E S

Clean Regulator/Fluororesin Type

Pressure Gauge Series

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Transcription:

1 Compact Manometer Series PPA Pressure measurements can easily be taken any time, anywhere. Compact and lightweight Portable type with a lightweight of only about 100 g (unit 50 g, battery 50 g) can also be held in the palm of the hand. Back light for easy viewing in dark locations Long service life of 12 months continuous operation One year of continuous operation is possible with 2 type AA batteries (3 V). Convenient hand strap for carrying Keeping practical use in mind, the hand strap is a standard feature. Zero/span calibration is possible Offset adjustment with the zero clear function, and span calibration with the trimmer can be performed. Peak/Bottom hold function With pressure being displayed, variations in supply pressure can be grasped instantly with one touch switching of the display from peak value to bottom value. Peak display Bottom display Auto power off function to save batteries Power turns off automatically if not operated for more than 5 minutes. Case holder is available The case holder is provided as an option to allow for situations where portability is not required. F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL 14-12-1

Series PPA 2 Pressure measurements can easily be taken any time, anywhere. Application Example Confirmation of air line source pressure Confirmation of regulator set pressure Human reading error is eliminated by the ability to confirm line pressure on the digital display. It is also possible to check pulsation in the source pressure using the peak/bottom display funcion. Setting a regulator can be performed more precisely than with a dial gauge by viewing the digital display while making the setting. Furthermore, power lines are not needed for this battery operated unit. Related products for line pressure measurement Convenient for easy line pressure measurement without removing piping or stopping supply pressure, etc. Tube coupler Pressure can be supplied or stopped by inserting or removing the tube. Finger valve Pressure can be easily applied or released by switching the control. For specifications, refer to page 14-12-4. Can also be used as an energy saving related device IN-442-5 Pressure probe Compact Manometer Series PPA Measures the total pressure received by an air blown workpiece Used in combination with the pressure probe (IN- 442-5), total pressure can be easily measured. 14-12-2

3 Precautions Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions. Warning Handling 1. The compact manometer can be used for measurement of air and non-corrosive gases. Please note that the accuracy of measurement for other fluids cannot be guaranteed. Furthermore, the construction is not explosion proof, and therefore, flammable gases should not be used. 2. Be certain to stay within the rated pressure range. Operation outside the pressure range will cause failure. 3. Do not intentionally swing around by the hand strap. If the strap breaks or comes loose, there is a danger of injury or damage, etc. 4. When installing or removing One-touch fittings on tubing, first confirm that the fluid to be measured is at atmospheric pressure. If tubing is disconnected while the fluid to be measured is in a pressurized state, the tubing may jump causing a danger of injury or damage. Also when connecting tubing, confirm that it is securely attached. 5. Instruction manual Read it carefully and understand the contents before using a product. Also, keep the manual in a location where it can be referred to at any time. 1. Keep condensate and foreign matter from getting into the fluid to be measured. If condensate or foreign matter is mixed in the fluid to be measured, this may cause failure or air leakage. If there is a possibility of these being contained in the fluid, use the meter via a filter or mist separator. 2. Do not drop or strike the unit, etc. Do not drop, strike or apply a large impact shock (980 m/s 2 ), as this may result in a failure. 3. Be certain to perform the zero clear function with pressure released to the atmosphere. When perfoming the zero clear function, this should be done with piping ports in an atmospheric release condition. If adjustment is performed at a pressure other than atmospheric pressure, the correct value will not be displayed. 4. Tighten One-touch fittings in accordance with the following. One-touch fittings should first be tightened by hand, and then further tightened approximately 1/6 of a turn using a tightening tool. If screwed in too far, this may cause air leakage due to breaking of threads or distortion of the gasket, etc. If not screwed in far enough, this may cause a loose fitting or air leakage, etc. Warning Operating Environment 1. Absolutely never use in an atmosphere where explosive gases are used. The compact manometer does not have explosion proof construction. If used in an atmosphere of explosive gases, there is a possibility of causing an explosion, and therefore, should absolutely not be used under these conditions. 1. Do not use where there is splashing of water or oil, etc. The compact manometer is not a dusttight and dripproof type, and should not be used where there is splashing water or oil, etc., as this may result in a malfunction. Warning Maintenance and Other 1. Perform maintenance and inspection on a regular basis. If there is an unintended misaction, misoperation, etc., or calibration has not been performed, there is a possibility of an incorrect value being displayed, making it impossible to ensure safety. 2. Do not disassemble or modify the unit. 1. Use manganese type AA dry batteries (R6) or alkaline type AA dry batteries (LR6). Do not use batteries other than the above, as this may cause failiure. 2. Insert the plus (+) and minus ( ) terminals of the batteries in the proper direction as indicated inside the unit. If the batteties are inserted incorrectly, this may cause them to leak or explode and result in damage to the unit. 3. Do not use old and new batteries or mix different types of batteries together. This may cause batteries to leak and result in damage to the unit. 4. Remove the batteries when the unit will not be used for a long period. 5. Do not use batteries if their voltage has dropped. Continuing to use them may lead to the display of incorrect values. 6. Do not touch the span calibration trimmer except when performing span calibration. Touching the trimmer may cause generation of an error in the measured pressure. Also do not turn it too hard (0.3 N m or less) or press it too hard (5 N or less). 7. Use a soft cloth to wipe the blot off of the body. In case of heavy soiling, wipe it off with a cloth soaked in a neutral detergent diluted with water after wringing it out thoroughly, and finish up by wiping with a dry cloth. F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL 14-12-3

4 Compact Manometer Series PPA PPA100/101/102 How to Order 0 1 2 PPA10 Pressure specifications 0.1 to 1 (For high pressure) 101 to 10 kpa (For vacuum) 10 to 100 kpa (For low pressure) Specifications Model Rated pressure range Pressure display Pressure display discrimination Mini. display units Error display Function Note) kpa mmhg kgf/cm 2 inhg PSI bar 0 M PPA100 for high press. 0.1 to 1 0.1 1 0.1 Option/Case holder Nil B None With PPA-B One-touch fitting type Symbol Applicable tubing size One-touch fitting Nil 04 06 None ø4 (mm size) ø6 (mm size) None KJH04-M5 KJH06-M5 PPA101 for vacuum 101 to 10 kpa 3 digit LCD back light 1/100 1 5 0.2 0.1 Unit specifications Over pressure, Memory data error, Change battery sign Peak/bottom display, Backlight, Auto power OFF Zero clear, Units display switching Nil With the unit switching function (1) M Fixed in SI unit (2) Note 1) With unit switching function is not permitted to sell for the domestic use in Japan, because the new Weight and Measure Act has been implemented since October 99. Note 2) Fixed unit For vacuum/compound pressure: kpa For positive pressure: Applicable tubing material None Nylon Soft nylon Polyurethane PPA102 for low press. 10 to 100 kpa 1 0.1 Withstanding pressure Fluid Power supply 1.5 200 kpa Air, Non-corrosive gases 3 V (DC), Type AA dry cell x 2 pcs. 200 kpa Battery life Response speed Display accuracy Repeatability Temperature characteristics Piping port Ambient operating temperature Ambient operating humidity Shock resistance Enclosure Weight 12 months continuous operation (Without backlighting, temperature conditions: at 25 C) 250 ms ±2% F.S. or less (Temperatue conditions: at 25 C) ±1% F.S. or less (Temperatue conditions: at 25 C) ±3% F.S. or less (0 to 50 C with 25 C standard) M5 x 0.8 0 to 50 C (With no condensation) 35 to 85% RH (With no condensation) 980 m/s 2 X, Y, Z directions, 3 times each IP40 (IEC standard) Approx. 100 g (Unit 50 g, batteries 50 g) 2 pcs. of type AA dry batteries (manganese R6 or alkaline LR6) are not included. Note) For the unit switching function (Types without the unit switching function is fixed in SI unit (kpa or ).) 14-12-4

Compact Manometer Series PPA 5 Description of Operating Parts Operation and Functions (PPA100 shown, Unit: ) Initial Setting Be certain to perform initial setting when using for the first time and after changing batteries, as the unit will indicate memory data error. P for peak display b for bottom display In lock mode Power button Power ON/OFF Peak mode switching LCD Present pressure display Peak/bottom value display Units display button Turns on back light 1. Confirmation of display 2. Press and hold the button for 6 seconds or more. 3. Release the button. 1. When the power is applied, and Err is displayed on LED, cut the power off for a time. After turning OFF (i.e. the state in which nothing is displayed on LCD), then proceed to 2. Besides, in the case that nothing is displayed on LCD, proceed to 2 with doing nothing. 2. Press and hold for 6 seconds or more. The unit will go into zero clear. When this happens CAL will appear on the LCD. 3. When zero clear is finished, the unit can be operated. Power ON Press the The power comes ON button. as it is pressed. When pressed and held for 6 seconds or more, the unit goes into zero clear. Press and hold the button for 3 seconds or more. Power OFF When pressed and held for 3 seconds or more, the power turns OFF. When there is no button operation for more than 5 minutes, the power turns OFF. (auto power OFF function) F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL 14-12-5

Series PPA 6 Operation and Functions (PPA100 shown, Unit: ) Auto Power OFF Function When the power is turned ON and there is no button operation for more tham 5 minutes, the power will turn OFF. Note) For cancelling this function, refer to the functions and operation of the lock mode (below). Lock Mode (Auto power OFF cancel) Unit Display Switching Note) This operation cannot be done for the type which does not have the unit switching function. 1. Press and hold the and buttons for 3 seconds or more. bar kgf High pressure (PPA100) bar PSI kgf 2. Press the button. kgf 3. Press the button. Vacuum (PPA101) kpa bar PSI inhg mmhg 1.When pressed continuously for 3 seconds or more, the unit on the LCD will flash. 2. The unit will change. (See the table below.) 3. The unit is set, and switching is finished. Note) The inhg unit cannot be displayed. Press and hold the and buttons for 6 seconds or more. Low pressure (PPA102) kpa bar PSI kgf The auto power OFF function is canceled by activating the lock mode (auto power OFF cancel). When continuously pressed for 6 seconds or more, L is displayed on the LCD. Moreover, when the power is turned OFF, the lock mode is released. Peak/Bottom Display Note) Since this is combined with power OFF operation, the button should be released at the point when P or b is displayed. Press the button. Turning on the Backlight Press the button. Press the button. Press the button. Press the button for 6 seconds or more. Zero Clear Do this when pressure is being displayed. Peak display Displays the maximum pressure value and P appears on the LCD. The display will change if pressure increases beyond the pressure value that is being held. Bottom display Displays the minimum pressure value and b appears on the LCD. The display will change if pressure falls below the pressure value that is being held. (These modes are convenient for confirming pressure fluctuations.) It normally lights up while the button is being pressed. In the lock mode, it lights up when pressed and turns off when pressed again. However, the maximum lighting time is approximately one minute. The zero point displayed at atmospheric pressure can be automatically adjusted. By this means it is possible to eliminate a display discrepancy at atmospheric pressure. Turn the power OFF. Release the supply pressure to the atmosphere. When continuously pressed for 6 seconds or more, zero clear is performed and CAL is displayed on the LCD. 14-12-6

Compact Manometer Series PPA 7 Dimensions 40 Connecting tube port 20 Accessory One-touch fitting F.R.L. PPA100 AV LOCK MODE(AUTO OFF CANCEL) AU AF BATTERY 1.5 Vx2 LR6, R6P 180 20 (Front) 110 X Refer to Note) 5 Fitting port diameter M5 x 0.8 Thread depth 5 Note) Dimension X includes the One-touch fittng ø4 ø6 ø1/4" 123 124 126 Span calibration Option/Case holder ø4.5 44 9.2 SMC 4.5 2-(R) MADE IN JAPAN AX + + (Back) 18 25 15 120 Body Type AA dry batteries (2 pcs.) 6.8 2 AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL 29 14-12-7

Series PPA 8 Error Correction When errors occur, they should be corrected as shown below. Display Contents Corrective action Entire display flashes Pressure being applied is above the rating. Memory data has probably been corrupted in some way. Battery voltage is low. Operate within the rated pressure range. Perform auto zero adjustment. Replace the batteries. Maintenance Span calibration method Do not touch the span calibration trimmer except when performing span calibration. 1. Perform zero clear at atmospheric pressure. 2. Apply the maximum rated pressure, and calibrate the span while comparing with a standard pressure gauge. 3. If the display value of the compact manometer is 0 after returning to atmospheric pressure, then calibration is complete. If the display value is not 0, calibrate again by repeating steps 1 and 2. Standard pressure gauge Compact manometer Finger valve Series VHK Specifications Compressor Related Products Useful for Measuring Line Pressure Valve type 2 port valve, 3 port valve Fluid Air Proof pressure 1.5 Maximum operating pressure 1.0 Operating vacuum pressure 100 kpa Ambient and fluid temperature 0 to 60 C Applicable tubing material Note) Nylon, Soft nylon, Polyurethane Option Bracket Note) Use caution with soft nylon and polyurethane at the maximum operating pressure. (For details, refer to Best Pneumatics Vol. 15.) For a vacuum application, use VHK2 (2 way valve). JIS Symbol 2 port valve 3 port valve A A I I Tubing material Tubing O.D. Trimmer These products are convenient for measuring line pressure easily without the need to remove piping or stop supply pressure, etc. Switching between pressurization and atmospheric release can be easily performed by switching the control. P For details, refer to Best Pneumatics Vol. 15. P R Replacing the batteries When battery voltage becomes low the entire LCD will flash. When the LCD flashes replace the batteries. Use 2 pcs. of type AA dry batteries. To replace the batteries, turn the power OFF and replace them within approximately 30 seconds. When not completed within 30 seconds, Err will be displayed. In that case, perform zero clear once again. In the event that the display runs out of control, remove the batteries for one minute or longer, and then perform zero clear again for inserting the batteries and turning on the power. Pressure can be supplied or stopped by inserting or removing a tube. Self-seal fittings Series KC Applicable Tubing Specifications Fluid Maximum operating pressure Proof pressure Ambient and fluid temperature Mounting section Thread Nut section Seal (Thread portion) Adaptor for copper family incompatible parts Principal Parts Material Body Stud Chuck spring Guide Collet release bushing Valve retainer Stopper Seal O-ring For details, refer to Best Pneumatics Vol. 15. Nylon, Soft nylon, Polyurethane ø4, ø6, ø8, ø10, ø12 Air 1.0 3.0 0 to 60 C JIS B 0203 (Taper threads for piping) JIS B 0211 Class 2 (Metric fine thread) With seal (Standard) Part C3604BD (Electroless nickel plated) C3604BD, PBT C3604BD (Thread portion) Stainless steel 304 C3604BD, Polyacetal (POM) POM POM C3604BD, Polyacetal (POM) NBR 14-12-8