Constant and Particle Free Point-of-Use Water Pressure

Similar documents
Levitronix LEVIBOOST 75 or 140. up to 75 or 140 l/min up to 20 or 37 gpm MANUAL

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

/ /

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Pressure on Demand. Air Pressure Amplifiers

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Air Amplifiers & SYSTEMS

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Design Features. General Description

MODEL HICV-130Ti7-331N. Lot NAGOYA JAPAN PAT.

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

Variable Area Flow Meters

Advanced Pump Control for Irrigation Applications

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Diaphragm process pumps

Process Pump. PAF3000 Series/PAF5000 Series

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

PLD 03 T A CASAPPA S.p.A.

CASH VALVE TYPE KP BACK PRESSURE VALVES

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Sullair Air Systems. *Assessment of the market for compressed air efficiency services. Technical report, U.S. Department of Energy, June 2001

Your local gas generation partner. Precision series Modular gas generation solution for GC.

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow, Level & Temperature Products for Ultra-Clean Processing P R E C I S I O N S E N S O R S

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

icon i150 / i350 Installation / Operation Manual

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

CAPITAL CONTROLS SERIES NXT3000

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

RCD - Ultra-Rugged Differential Pressure Flowmeter

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

directional control valve series cv691

Key Features & Advantages of JEHA MK IV (5,000 PSI Hydraulic Test Stands)

Axial piston pumps type PVC

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

CCT-7320/ROC-2313 Reverse Osmosis Controller

WHITEPAPER. Integrated process monitoring of dosing pressures

Axial piston pumps type PVC

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids


Residential Pressure Booster Systems

L6090 (LC04M-CBL) - L6095 (LC04M-CBD)

Recirculating Coolers

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

WORKHOLDING APPLICATION BOOKLET

Series Environmental Chambers

Over 20,000 Strain Gage Target flowmeters installed since 1952.

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Glass tube flowmeters Series 2000

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Customer Responsibilities

780S Ultra High Purity Series

Mass Flow Controller (MFC) for Gases

Heat Pump Connections and Interior Piping

Additel 761 Automated Pressure Calibrators

Improving distillation tower operation

Electrically Operated Pressure-Relief Cartridge, Size 10

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Mass Flow Controller (MFC) for Gases

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

PM105 PRESSURE METER USER S MANUAL

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

SINGLE VALVE WITH LOW-FLOW BYPASS

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Double Pilot Operated Cartridge Check Valve, Size 8

PRC CO ² -LASER PRESENTATION

INSTALLATION & MAINTENANCE INSTRUCTIONS

Additel 761 Automated Pressure Calibrators

CO 2 and O 2 scrubbers

Proportional Throttle Cartridges, Size 16

ADT 761 Automated Pressure Calibrator

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Model EXAxt AV550G. Averaging Oxygen Analyzer

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

Air preparation units

SPECIFICATIONS PARTICLE SENSOR KS-19F Higashimotomachi, Kokubunji, Tokyo , Japan

Potter Nitrogen Generators

Valve Proving System VDK 200 A S06*

Reverse Osmosis System Installation Guide and Operation Manual.

Applications. What moves your world

TECHNICAL SPECIFICATION. SPC-1 Stirling Process Cryogenerator

Ultrasonic level transmitter and indicator

Inverse Prop. Pressure-Relief Cart., Size 2 4

Monitoring device NTS 30

Pressure independent control valve (PICV) FLOWMATIC

PRESSURE COMPENSATORS TECNORD

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

BERMAD Fire Protection Hydraulic Control Valves

TECHNICAL SPECIFICATION. SPC-4 Stirling Process Cryogenerator

Transcription:

Constant and Particle Free Point-of-Use Water Pressure for High Quality UPW and DI-Water Always the right pressure.

Higher Cost Pressure and More Rigid Specifications In the Microelectronic world pressure variations in UPW and DI-Water supply lines can be a problem for tools and processes. More and more, sophisticated manufacturing require a highly constant inlet pressure in order to keep the sensitive internal tool operations within the expected process window. As a result, any pressure fluctuations could possibly reduce process yields. Based on continuously increasing cost pressure however, water treatment systems are often designed at their limits. Further tool expansions often lead to unstable water supply situation. As a result, uncontrolled pressure fluctuations could cause extended cycle time, process interruptions, or even tool shut-downs. Major cost impacts are the consequence. pressure Challenges of Fluctuating Water Supply Uncontrolled process and increased cycle time Risk of tool shut-downs Particle problems caused by passive pressure control components time Graph conveys typical uncontrolled pressure fluctuations Severe Problems in Manufacturing FABS In order to cope with these challenges, Microelectronic Manufacturers either face substantial investments in additional water treatment infrastructure or try to optimize the existing installed system. Unfortunately only passive components such as pressure regulating valves are normally used which often results in a temporary unstable water pressure condition along with high particle contamination levels.

How can the Problem be solved? Other than with passive elements an actively controlled system not only increases pressure actively but also is able to compensate fluctuations in water consumption. As a result, a very accurate and constant pressure is provided, independent from water supply pressure and water consumption by the process tools. tool supply tool pressure Functional Diagram LEVIBOOST TM tool Dynamic Controlled Process Defined and controlled output pressure No process disturbances Particle-free High Purity design time Graph conveys dynamically controlled pressure Working Principle A pressure transducer monitors the current tool incoming pressure and transmits the actual value to the pump controller. Based on the required set pressure, the magnetically levitated and electronically controlled pump dynamically increases the water pressure to the given set point. By doing so, this closed loop pressure control design not only compensates supply pressure fluctuations, but also pressure variations caused by individual water consumption of the process tools in line. Always the right pressure.

LEVIBOOST TM Levitronix Water Booster Kit The innovative Levitronix Water Booster Kit LEVIBOOST TM offers a flexible, highly reliable and cost efficient solution for any UPW and DI-Water booster needs. Features Absolute accurate and constant water pressure Independent from variations in water supply Independent from variations in water consumption No particle generation based on the revolutionary magnetic levitation pump, contact-free operation Minimal foot print required - ultra compact design allows sub-floor installation Flexible performance ~1 l to 140 l/min ~0,25 to 37 gpm up to 500 l/min/132 gpm on request LEVIBOOST 75 up to 75 l/min up to 20 gpm LEVIBOOST 140 see performance details on Flow/Pressure Curves Very economical - no water system infrastucture modifications required Low cost of ownership - 2 year maintenance contact included Global service and application support up to 140 l/min up to 37 gpm see performance details on Flow/Pressure Curves Always the right pressure.

LEVIBOOST TM Main Components Proven High Purity components guarantee long life time, low maintenance and low particle contamination levels. Plug-and-Play installation. 3 1 2 1 Levitronix Motor with Pump Head and Cooling Module (optional) 2 * Levitronix Pump Controller for dynamic flow control 7 6 5 4 3 4 Pressure Transducer provides actual output pressure data User Interface Start, Stop, Set pressure, display set and actual pressure 5 System Status Active: System runs in Control loop 6 System Warning Active: Pump is running but system needs attention 7 System Error Active: Pump is not running based on system error

LEVIBOOST Design Elements Cabinet Element Cabinet construction Cabinet Drain Leak Detection Exhaust Air supply Description PP and PVC (FM4910 approved, fire retardant) 3/8 FNPT (With plug when not in use) Turn off the pump and System Error will be active Venting slots CDA or N2 (for pump cooling - optional) Connection: Inlet Pressure: Air Consumption: 1/4 On-touch tube fitting ~ 1-3 bar (14-43 psi) 110 Liter/min = 3.8 SCFM @ 1 bar 210 Liter/min = 7.4 SCFM @ 2 bar Air flow regulator integrated Hydraulic Wetted Components Pressure Boost Media Connection Inlet and Outlet High purity PFA or PTFE (Others on request) LEVIBOOST TM 75 up to 42 l at p 2.5 bar, 11 gpm at p 35 psi LEVIBOOST TM 140 up to 115 l at p 2.5 bar, 30 gpm at p 35 psi UPW, Hot UPW and DI-water up to 18.2 MOhm and up to 90 C/194 F Acids and caustics 90 C/194 F after technical consultation Flare connection 1 Electronic Power Supply EMO Safety Interfaces 1 x 230 V, ± 10 %, 50/60 Hz LEVIBOOST TM 75 3 A / LEVIBOOST TM 140 8 A (rms) With switch guard External input for turn off Internal circuit breaker RS232: Service Port Digital Input: Remote Interface (remote EMO) Dimensions 15.6 inch 395.0 mm 17.0 inch 432.5 mm FLUID INLET 15.7 inch 398.3 mm 19.6 inch 497.9 mm 14.6 inch 370.0 mm Always the right pressure.

Flow/Pressure Curves LEVIBOOST TM 75 3.5 gallons/min 0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 50 3.0 2.5 Specific gravity = 1g/cm³ Viscosity = 0.7 cp Liquid Temp.: 40 C 40 2.0 bar 1.5 30 20 psi 1.0 0.5 10 0.0 0 10 20 30 40 50 60 70 80 liters/min 0 Flow/Pressure Curves LEVIBOOST TM 140 5.0 4.5 4.0 3.5 3.0 bar 2.5 2.0 1.5 1.0 0.5 0.0 gallons/min 0 5 10 15 20 25 30 35 0 20 40 60 80 100 120 140 liters/min Specific gravity = 1g/cm³ Viscosity = 0.7 cp Liquid Temp.: 40 C 70 60 50 40 psi 30 20 10 0

LEVITRONIX The Company Levitronix is the world-wide leader in magnetically levitated bearingless motor technology. Levitronix was the first company to introduce bearingless motor technology to the medical and industrial markets. The company is ISO 13485, EN 46001 and EN ISO 9001 certified. Production and quality control facilities are located in Switzerland. In addition, the Levitronix R&D team provides third party contract services in cooperation with other research groups. LE VITR ONIX Representatives US Headquarters Levitronix LCC 45 First Avenue Waltham, Massachusetts 02451 USA Phone: Fax: e-mail: (+1) 781 622 5070 (+1) 781 622 5090 usoffice@levitronix.com European Headquarters Levitronix GmbH Technoparkstrasse 1 CH-8005 Zurich Switzerland Phone: Fax: e-mail: (+41) 1 445 19 13 (+41) 1 445 19 14 office@levitronix.com www.levitronix.com The technical data is not binding and not an expressly warranted characteristic of the goods. It is subject to change. Levitronix RV 01.09