Single-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA

Similar documents
DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

Model MTB-ASME Horizontal Bladder Tanks

Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

S Surge Arresters

Vertical Bladder Tanks

System Pressure Manager Standard & System Pressure Manager Plus

Continental Industries TRANSITION FITTINGS or FAX Visit

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER

Installation. S&C Vista Underground Distribution Switchgear. UnderCover, Vault-Mounted, and Pad-Mounted Styles. Instruction Sheet

IECEx Certificate of Conformity Annexe

INSTRUCTION BOOK CARE AND MAINTENANCE OF OIL-IMMERSED (R-TEMP-OR SILICONE IMMERSED) TRANSFORMERS

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS

Check with local zoning official for property line distance requirements.

Medium voltage standard-duty, heavyduty, and extreme-duty single-phase, unfused capacitor units and accessories

Effective May 2017 Supersedes August 2005 (S )

COOPER POWER SERIES. UltraSIL Polymer-Housed Distribution-Class MOV Surge Arrester Installation Instructions. Surge Arresters MN235006EN

S Surge Arresters. Handling and Storage. Standards. Acceptance and Initial Inspection

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

MaxSB - Low Voltage Switchboard

MEDICAL EQUIPMENT CATALOG

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

Residential Swimming pools

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No

[Instruments for vacuum measurement, checking and adjustment] 3

FV Flash Vessel Installation and Maintenance Instructions

INSTRUCTION MANUAL Pressure Relief Device LPT

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

Continental Industries STEEL SERVICE TEES or FAX Visit

WHEATLEY Series 500 Swing Check Valve

61-31 Corrugated Radiators

COOPER POWER SERIES. VFI SF6-insulated vacuum fault interrupter installation, operation and maintenance instructions. Switchgear MN285004EN

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

WELL COMPLETION & PROTECTION. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD

Product Specifications Specialty Junction Boxes

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Manual Actuated Boiler Blowdown Valves

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Security and confidence at height.

Inspection Recommendations

METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES IEC COMPLIANT

Equipment Accuracy / Selection

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Technical Diving Equipment

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

Types and approvals. Page 1/6. Data Sheet

PRODUCT SPECIFICATION. SFP+ Cage and Cage Assembly 1 of 8 A

COOPER POWER SERIES. Under-oil arrester disconnector installation/operation instructions. OEM Equipment MN800010EN

It is essential that the maintenance staff is qualified for electrical works and follows safety procedures.

Vertical and Horizontal Bladder Tanks

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Technical Data. General specifications. Rated operating distance s n 5 mm

Spectrum AquaLight (SAL ) Color Underwater Light Owner s Manual

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

D I G I T A L C L A M

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Pressure Regulating Valves. Models 44, 77 & 68 PS\ UL. Pressure Relief Valve. Dorot Fire Protection Division. Certification & compliance by design

COOPER POWER SERIES. UltraSIL polymer-housed VariSTAR surge arrester IEC for MV systems to 36 kv installation instructions

WHEATLEY Series 822/820 Swing Check Valve

$ Plan Review Fee when Permit Application is submitted HOT TUBS AND SPAS BUILDING PERMIT APPLICATION. COST: $80.

NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016

Ground Fault Circuit Interrupter(GFCI) Policy

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Distribution Transformer Instruction Manual

Technical Data. Dimensions

SR100 Series Service Regulators. Technical Bulletin

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.

DESIGN ENVELOPE 6800 G 1 DUTY PUMP

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

Prewired position switches FA series

Arran LED Floodlight Luminaire

Selection of Electrical PPE Tables

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

A28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Operating Instructions

XCE: Explosionproof Control Enclosures

Workshop Compressors CLASSIC Series

Pressure Dump Valve Service Kit for Series 2300 Units

Hydraulic Piston Accumulators

Ford Service Saddles and Tapping Sleeves

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Torque Tube TB300 Digital Transmitters

Installation and commissioning instructions 255 series and 256 series

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Workshop Compressors CLASSIC Series

INSTRUCTION MANUAL. Gas Salamander

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

CUSTOM ENCLOSURE CUTOUTS

The MAXX Press DIGITAL CAP OPERATOR S MANUAL

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Transcription:

62-10 Single-Phase Pad-Mounted Distribution Catolog Transformers Section Howard Industries, Inc. Certifi ed to ISO 9001:2015 62-10 Single-Phase Pad-Mounted Distribution Transformers 5-500 KVA 10002179 ISO 9001:2015 Howard Industries, Inc. Introduction Howard Industries manufactures a complete line of single-phase pad-mounted distribution transformers, suitable for use on any residential or commercial underground distribution system. Basic styles include the IEEE Type-1, the low-profi le IEEE Type- 2, and the ultra-compact Space-Saver. Howard transformer designs are optimized for lowest total owning cost or lowest purchase price as specifi ed by the customer. They are designed and built in accordance with all national transformer standards and are compliant with applicable USDOE energy effi ciency requirements. Certifications and Standards Compliance Howard transformers comply fully with all applicable U.S. national standards and qualify for all current governmentmandated Made-in-America initiatives. ISO-9001 certifi ed manufacturing facility IEEE, ANSI, and NEMA transformer standards, as applicable IEEE transformer enclosure integrity standard C57.12.28 (mild-steel enclosures) or C57.12.29 (stainless-steel enclosures), as specifi ed DOE Energy Effi ciency Standard 10 CFR Part 431 for distribution transformers, as applicable Rural Utilities Service (RUS) Specifi cation U-5, when specifi ed Canadian Standards Association (CSA) transformer standards, when specifi ed Document No. 2.4.187 Copyright 2017 Howard Industries, Inc. 1

Single-Phase Pad-Mounted Distribution Transformers Doc62-1062-10 Standard Product Ratings and Features Our standard product line includes a complete range of kva capacities, voltage ratings and features to satisfy most typical distribution-class applications. Check with the factory or your local Howard Sales Representative for the availability of optional ratings and features. Single-phase self-cooled kva ratings IEEE Type-1 design 5, 10, 15, 25, 37.5, 50, 75, 100, 167, 250, 333, 500 IEEE Type-2 design 5, 10, 15, 25, 37.5, 50, 75, 100, 167, 250 Space-Saver design 5, 10, 15, 25, 37.5, 50 High-voltage ratings 2.4 kv through 19.9 kv Low-voltage ratings through 600 Volts BIL levels per IEEE Standard C57.12.38 Average temperature rise 65 C Frequency 60 Hertz Impedance and impedance tolerance per IEEE Standard C57.12.00 Audible sound level per NEMA Standard TR-1 Welded mild-steel oil compartment Removable mild-steel terminal compartment hood with stainless-steel hinge pins and barrels Removable mild-steel sill Recessed oil compartment bottom Domed hood and oil compartment to resist water retention Recessed stainless-steel lifting provisions Corrosion-resistant locking assembly with captive penta-head security bolt, floating nut and padlock provision Tank grounding provisions Oil-fill/oil-level plug Oil drain plug Embossed bushing mounting surfaces Two-part epoxy undercoat Electrostatically-applied powder paint primer coat, with polyurethane topcoat for excellent resistance to chipping, fading, abrasion and corrosion Accessory mounting bracket (parking stand) Polymer mounting pad (Space-Saver designs only) Two externally-clamped molded polymer universal high-voltage bushing wells for loop-feed operation or one externally-clamped high-voltage bushing well for radial-feed operation, as specified Two externally clamped molded polymer low-voltage bushings with threaded copper studs and one molded polymer neutral terminal with removable ground strap (removable ground strap standard on 240/120 and 480/240 ratings only) Automatic pressure relief device Electrical grade silicon steel core Electrical grade mineral oil insulating fluid with oxidation inhibitor Bushing designations (stencil or self-adhesive label) Laser engraved aluminum nameplate Optional Product Ratings and Features A wide range of optional features and accessories are available to customize transformers for special applications. Check with the factory or your local Howard Sales Representative to discuss these and other options. 50 Hertz operation Stainless-steel or hybrid mild-steel/stainless-steel enclosure. Available stainless grades include 409, 304 and 304L Hi-Lift raised locking mechanism for improved ergonomic lift and reduced exposure to corrosion Energy efficient amorphous metal core Sill-mounted faulted-circuit indicator or provisions only Temporary service access provision with cover plate Two-position or four-position rotary high-voltage load-break switch Internal Fault Indicator (IFD device) High-voltage bushing wells with replaceable studs High-voltage bushing inserts Integral one-piece large interface bushings Removable low-voltage ground strap (standard for 240/120 and 480/240 ratings) Low-voltage terminals including various screw-on and slip-fit connectors Internally-mounted expulsion fuse with or without internally-mounted series-connected partial-range current-limiting fuse (current-limiting fuse not available on Space-Saver designs) Draw-out expulsion fuse series-connected with isolation link or with internally-mounted partialrange current-limiting fuse (current-limiting fuse not available on Space-Saver designs) 2 Copyright 2017 Howard Industries, Inc. Document No. 2.4.187

62-10 Single-Phase Pad-Mounted Distribution Transformers Dry-well draw-out full-range current-limiting fuse (not available on Space-Saver designs) Internally-mounted low-voltage circuit breaker with or without emergency overload feature (not available on Space-Saver designs) Internally-mounted MOV high-voltage lightning arrester with or without externally-operable groundlead disconnect High-voltage tap switch with externally-operable handle located inside the terminating compartment (not available in combination with series-multiple switch) High-voltage series-multiple switch with externallyoperable handle located in the terminating compartment (not available in combination with high-voltage tap switch) Interlaced low-voltage windings Drain valve with or without sampling device Temperature gauge Liquid level gauge Pressure/vacuum gauge Tank ground connectors Hold-down cleats Lifting bolts Hex-head security bolt Ester-based insulating fluid (Cargill FR3) Custom stenciling or labeling NEMA safety labels Laser engraved stainless-steel nameplate Document No. 2.4.187 Copyright 2017 Howard Industries, Inc. 3

Single-Phase Pad-Mounted Distribution Transformers Doc62-1062-10 Table 1: Typical Dimensions for Single-Phase Pad-Mounted Transformers 1 KVA Height 2 IEEE Type-1 IEEE Type-2 Space-Saver Width 2 Depth 2 TC Depth 3 Height 2 Width 2 Depth 2 TC Depth 3 Height 2 Width 2 Depth 2 10 32 33 28.5 16 24 33 28.5 16 24 23 28.5 16 15 32 33 28.5 16 24 33 28.5 16 24 23 29.75 16 25 32 33 29.75 16 24 33 29.75 16 24 23 30.5 16 37.5 32 33-34 31.5 16 24 33-34 31.5 16 25.75 23 33.75 16 50 32 33-36 32.75 16 25.75 33-36 32.75 16 25.75 23 35 16 TC Depth 3 75 35 34-36 35 16 25.75 34-36 35 16 Note 5 Note 5 Note 5 Note 5 100 35 34-36 37.75 16 28 34-36 37.75 16 Note 5 Note 5 Note 5 Note 5 167 37 36-38 43.75 16 32 36-38 43.75 16 Note 5 Note 5 Note 5 Note 5 250 Note 4 Note 4 Note 4 Note 4 Note 4 Note 4 Note 4 Note 4 Note 5 Note 5 Note 5 Note 5 333 Note 4 Note 4 Note 4 Note 4 Note 4 Note 4 Note 4 Note 4 Note 5 Note 5 Note 5 Note 5 500 Note 4 Note 4 Note 4 Note 4 Note 4 Note 4 Note 4 Note 4 Note 5 Note 5 Note 5 Note 5 1 Dimensions are approximate and are not for construction purposes. Contact the factory for exact dimensions. 2 Height, Width and Depth are outside overall dimensions not including radiators. 3 T/C Depth is the dimension inside the terminating compartment between the cover and the tank faceplate. 4 Consult the factory for typical dimensions for 250, 333 and 500 kva transformers. 5 Space-Saver design is not available above 50 kva. 4 Copyright 2017 Howard Industries, Inc. Document No. 2.4.187

62-10 Single-Phase Pad-Mounted Distribution Transformers Table 2: Typical Weights and Fluid Volumes for Single-Phase Pad-Mounted Transformers 1 KVA Weight 2 (lbs.) IEEE Type-1 IEEE Type-2 Space-Saver Fluid Volume (gal.) Weight 2 (lbs.) Fluid Volume (gal.) Weight 2 (lbs.) Fluid Volume (gal.) 10 700 30 550 25 450 20 15 700 30 550 25 450 20 25 750 35 600 25 525 20 37.5 800 35 700 30 650 25 50 900 40 750 35 700 30 75 1100 50 950 40 Note 4 Note 4 100 1250 55 1200 50 Note 4 Note 4 167 1750 75 1650 65 Note 4 Note 4 250 Note 3 Note 3 Note 3 Note 3 Note 4 Note 4 333 Note 3 Note 3 Note 3 Note 3 Note 4 Note 4 500 Note 3 Note 3 Note 3 Note 3 Note 4 Note 4 1 Weight and fluid volume are approximate and are not for construction purposes. Contact the factory for exact weight and fluid volume. 2 Weight does not include shipping pallet. 3 Consult the factory for typical weight and fluid volume for 250, 333 and 500 kva transformers. 4 Space-Saver design is not available above 50 kva. Quality Assurance Our quality management system is designed to ensure that all of our products and services meet or exceed customer requirements and is certified by DQS-UL as ISO-9001:2015 compliant. The ISO-9001 standard covers design, manufacturing, and servicing systems, and is the most stringent and comprehensive standard in the internationally recognized ISO-9000 series of quality standards. In addition to the many quality inspections and tests throughout the manufacturing process, final completion tests are conducted on 100% of production to ensure conformance to specifications and standards requirements. These tests are conducted in accordance with IEEE C57.12.00 Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers and IEEE C57.12.90 Standard Test Code for Liquid-Immersed Distribution, Power and Regulating Transformers and Guide for Short Circuit Testing of Distribution and Power Transformers. Factory test systems are calibrated regularly according to industry standards, with NIST traceability for calibration of all lossmeasuring systems. Document No. 2.4.187 Copyright 2017 Howard Industries, Inc. 5

Single-Phase Pad-Mounted Distribution Transformers NOTES Doc62-1062-10 6 Copyright 2017 Howard Industries, Inc. Document No. 2.4.187

62-10 Single-Phase Pad-Mounted Distribution Transformers NOTES Document No. 2.4.187 Copyright 2017 Howard Industries, Inc. 7

Single-Phase Pad-Mounted Distribution Transformers, 5-500 KVA Catalog Section 62-10 Document No. 2.4.187, Revision 1, April, 2018 Copyright 2017 Howard Industries, Inc., Laurel, Mississippi Telephone: 601-425-3151 Fax: 601-649-8090 E-mail: mkt@howard.com Web: howardtransformers.com