October 10, 2018 Annual Seminar New England Pipeline Safety Representatives Meredith, New Hampshire Randy Knepper Director of Safety, NHPUC

Similar documents
New Hampshire Public Utilities Commission CFR 49 Part 192 Regulations. MINIMUM Pipeline Safety Regulations

Shut-Off Valves and Valve Boxes

OPERATING PROCEDURES

Eliminating Medical Gas Shutdowns for 10 years

/2004 US/CA

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

Responding to Natural Gas Pipeline Emergencies

High-Pressure Boiler Inspection Procedures: A Complete Checklist

GAS DELIVERY PRESSURE AND MEASUREMENT

Fire's Edge. Fire Pit or Fire Pit Insert Model 100A-M (Manual Operation) OWNER S MANUAL / OPERATING AND MAINTENANCE INSTRUCTIONS

APPENDIX A GLOSSARY AND ACRONYMS

Overview EUSSAM12. Carry out tightness testing and direct purging of gas installations

September 2018 Pressure Test

Summary of the MRA LPG Codes of Practice

Your safety and the safety of others are very important.

Propane Conversion Kit Instruction

Gas Countertop Hot Plates

Standard Gas Countertop Griddle

Water Pressure Reducing Valves

Propane Conversion Kit Instruction

INSTALLATION OPERATION MAINTENANCE

Natural Gas Connection Policy and Procedures

Propane Conversion Kit Instruction

TECHNICAL DATA. than the water inlet pressure to the concentrate

Distribution Connection Forms

Specialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions

Overview EUSDSG3.12. Install gas meters and regulators (2.5 to 16.0m3/hr)

GAS SUPPLY APPLICATION GUIDE

INSTALLATION & OPERATION MANUAL FOR Teppan-Yaki Griddles

GAS VALVE PRESENTATION AND APPROVAL OF $30,000 FOR MANUAL GAS VALVE UPGRADES

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

THE GENERAL ASSEMBLY OF PENNSYLVANIA SENATE BILL INTRODUCED BY DINNIMAN, COSTA, RAFFERTY, FOLMER AND MENSCH, NOVEMBER 1, 2017

Lockout Tagout Policy

UTAS EH&S INSTRUCTION No. 036 June 2012 Revision No. 3. Purging of Flammable Gas Equipment and/or Piping (Explosion Hazard)

Quick Specs. INERGEN Clean Agent Fire Suppression System

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Valve Replacement: Using Non-Intrusive Isolation Technology to Minimize Production Downtime

GAS PIPELINE SAFETY GUIDE.

INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS

Regulator from 1800 B series

Nottingham Township 909 Sugar Run Road Eighty Four PA (724) Fax (724)

PIPELINE SAFETY. Darin Burk, Manager Pipeline Safety. January 28, 2014

Gas Countertop Griddle

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

Pipeline Integrity Valve Spacing Engineering Assessment (CDN) Grande Prairie Mainline Loop 2 (Progress Section) NPS 36

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

INSTALLATION, OPERATION, SERVICE & PARTS MANUAL FOR STOCK POT RANGE MODELS VSP100, VSP200 & VSP300

Tool Box Talk. Confined Space Entry New Construction Standard (2015)

Wet pipe low flow foam/water system

Overview EUSDSG3.6. Gas tightness testing and direct purging

Decommissioning Ageing Infrastructure: Abandoning or Re-Routing Hydrocarbon Pipelines. Dave Vernon - Director of Isolation Services

Please read this document of Terms and conditions carefully so that you fully understand our responsibilities and your commitments.

TK Torch Match Lit WARNING: FOR OUTDOOR USE ONLY

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

Spirax Compact FREME Flash Recovery Energy Management Equipment

Installation and Operation Instructions

Lockout / Tagout Safety Program

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

Operating and Maintenance Instructions

Safety Manual: Hazardous Energy. January, 2017

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

Installation Instructions

Installation Instructions For Natural Gas Conversion

Florida Senate SB 1694 By Senator Haridopolos

WARNING: FOR OUTDOOR USE ONLY

BPB26-1 AND SSPB26-1 PATIO BASE INSTALLATION INSTRUCTIONS

Toll Free: (877) Fax: (877) TK Torch Match Lit WARNING: FOR OUTDOOR USE ONLY

Natural Gas. Safety Information. For Excavators and Contractors. Información en español en el interior. swgas.com/safety

GAS SUPPLY DESIGN GUIDE

CONTROL OF HAZARDOUS ENERGY LOCKOUT/TAGOUT PROGRAM

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 Utilities Gas Emergencies Revised

KC Series Gas Components and Supply Design Guide

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

RE: PROPANE SYSTEM & REGULATOR TESTING/INSPECTION PROCEDURE

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

RADIANT GAS BROILER VULCAN MODEL RGB-8

Natural Gas Conversion Kit

Products for Cryogenic Applications

SL G3. Warning

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Covered Task 614OP Training Guide Purging Pipeline Facilities with Air or Inert Gas

Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve

INSTALLATION AND OPERATING INSTRUCTIONS

ARKANSAS TECH UNIVERSITY FACILITIES MANAGEMENT HEALTH AND SAFETY MANUAL (LOCKOUT/TAGOUT) 30.0

Carter Option X Valve connector assembly. Maintenance manual

VALVE CRITICALITY MODELING

CONTROL OF HAZARDOUS ENERGY (LOCKOUT/TAGOUT)

Gulfstream Natural Gas System

NYCBS November 2014 Monthly Report

SL G3 - Fuel Conversion to Natural Gas (LP to NG) P-Kit 301

Cal/OSHA T8 CCR 1536 Cal/OSHA T8 CCR 4799 Cal/OSHA T8 CCR 4845 Cal/OSHA T8 CCR 4848

Gas Distribution Connection Forms

V8200A,C,H,M and VR8200A,C,H,M Continuous Pilot Combination Gas Controls

Committee Input No. 59-NFPA [ Section No. 5.9 ]

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

Incorrect installation, adjustment, or misuse of this burner could result severe personal injury, or substantial property damage.

City of Cerritos SWIMMING POOL, SPA AND EQUIPMENT APPLICATION. (Please print or type) Name: Phone: ( )

Transcription:

SOFT OFFs Safety and Convenience Considerations October 10, 2018 Annual Seminar New England Pipeline Safety Representatives Meredith, New Hampshire Randy Knepper Director of Safety, NHPUC

Some years ago, LDCs began to use the practice of what has come to be known as Soft Offs when discontinuing gas service to customers. The term Soft Off describes when an LDC closes a gas account but does not physically visit the premises and lock the gas meter

Inside meter for first floor service valve still in on position

Schenectady in Capital Region, NY Service territory of a large operator Foreclosure Auction October 2012 City became property owner 2 unit property owned by City Agency as of Feb 2013 As of March 2013 both electric and gas accounts were marked inactive

The Large Operator did not deactivate the service line House was vacant and subject to vandalism and squatters use 541 days later on August 18, 2014 squatters had likely cut inside pipes for scrap metal 2 days later on August 20, 2014 the house exploded No fatalities, no bodily injury, property damage value of house

Operator piping extended into the interior of basement and gas meters were located inside Determined damage occurred upon the gas piping downstream of the meter Low Pressure, 1.25 gas pipe bare steel Incident most likely would have been avoided if gas had been shut off and locked.

Should the operator even be having soft off policies? What is the appropriate duration of soft off policies? 5 days, 10 days, 30 days, 60 days? The longer the duration the higher the risk to vandalism and removing interior gas piping Copper especially is easily removed because of its higher scrap value and ease of removal

The Large Operator did not follow its Meter Turn Off (Lock) Procedure The Large Operator was using its Soft Off Policy No admission of liability but will incur shareholder funding to accomplish 4 objectives:

1. Piloting a program for remote automated service valve shutoffs 2. $500,000 shareholder liability in educating public on vacancy issues and identifying vacant properties 3. Training CSRs on inactive accounts, alteration of scripts, improvements to review of gas usage on inactive accounts 4. Increased effort to move meters from inside to out

INCIDENT #2

Watermill is in Southhampton, Suffolk County, Long Island NY Service territory of a large operator Dec 11, 2014 Former Owner of Residential Property requested termination of service Phone Call to Customer Service Rep House was scheduled to undergo renovations so gas was not needed during the renovation period (months)

The Large Operator did not deactivate the service line as requested Renovations began, house was vacant except for workers 61 days later on February 11, 2015 the house exploded 2 contractors working for the new owner were hurt, one suffered burns on face and required hospitalization Fire erupted and continued as gas was supplying the fuel

2 gas workers who happened to be working in area heard the event, rushed to scene and shut off the curb valve prior to firefighters arriving Inside demolition was occurring within basement Operator piping extended into the interior of basement and gas meter was located inside Determined damage occurred upon the gas piping upstream of the meter.

Demolition permit was listed as pending Structure demolition permits in New Hampshire require the Gas Operator to sign off on the demolition permit signifying gas disconnected and other utilities disconnected Does interior demolition require permitting in your jurisdictions? Have you looked into this? Do you require confirmation of all demolitions?

The Large Operator did not follow its Meter Turn Off (Lock) Procedure The Large Operator was using its Soft Off Policy No admission of liability but will incur shareholder funding to: $500,000 civil penalty in educating smaller contracting community in renovations, increase public awareness Training CSRs on inactive accounts $1,498,000 in an excess flow valve enhancement program

½ Service was inserted into ¾ shown outside front wall

Melted steel to plastic transition fitting

Melted steel to plastic transition fitting inside wall

Inside service and piping

Subpart M - Maintenance 192.727 Abandonment or Deactivation of Facilities (a) Each operator shall conduct abandonment or deactivation of pipelines in accordance with the requirements of this section. Section here refers to 192.727 all parts Standard language

(b) Each pipeline abandoned in place must be disconnected from all sources and supplies of gas; purged of gas; in the case of offshore pipelines, filled with water or inert materials; and sealed at the ends. However, the pipeline need not be purged when the volume of gas is so small that there is no potential hazard. Pipeline applies to service lines and mains 727 (b) applies to abandoned pipelines not deactivated

(b) Each pipeline abandoned in place must be disconnected from all sources and supplies of gas; purged of gas; in the case of offshore pipelines, filled with water or inert materials; and sealed at the ends. However, the pipeline need not be purged when the volume of gas is so small that there is no potential hazard. 4 requirements: (1)disconnected, (2) purged, (3) filled with inert materials and (4) sealed.

(c) Except for service lines, each inactive pipeline that is not being maintained under this part must be disconnected from all sources and supplies of gas; purged of gas; in the case of offshore pipelines, filled with water or inert materials; and sealed at the ends. However, the pipeline need not be purged when the volume of gas is so small that there is no potential hazard. This applies to inactive mains that are no longer being maintained Same 4 requirements: (1)disconnected, (2) purged, (3) filled with inert materials and (4) sealed. This does not apply to abandonments This does not apply to service lines thus not the focus of this presentation

(d) Whenever service to a customer is discontinued, one of the following must be complied with: (1) The valve that is closed to prevent the flow of gas to the customer must be provided with a locking device or other means designed to prevent the opening of the valve by persons other than those authorized by the operator. (2) A mechanical device or fitting that will prevent the flow of gas must be installed in the service line or in the meter assembly. (3) The customer's piping must be physically disconnected from the gas supply and the open pipe ends sealed.

727 (d) applies to deactivated services Does not apply to abandoned services Does not apply to mains Must do at least 1 of 3 options The operator may do more than 3 options

Commission approved June 2015 The Soft Off Policy applies only to Largest Operator No Safety Division Input Policy based on Cost of Gas proceedings and Consumer Affairs input Policy Goal to reduce cost of sending out technicians twice

Soft Offs do not apply to commercial accounts Soft Offs only apply to residential accounts with 1) an outside meter 2) No gas appliances can be removed Soft Offs do not apply to Residential customers that: a) Have inside meters b) Are removing at least 1 appliance c) Indicate gas will be off for extended period d) Indicate premise will be demolished

Soft Off duration can last up to 30 days after termination request After 30 days meter shut off request is generated Meter Shut offs can take place year round including the winter period

Our second largest operator has almost identical Soft Off Procedures that predate those that are listed in previous slide

What is the appropriate balance between customer convenience and safety? Should there be any balance or should safety always take priority in every instance? Do you have a copy of your Company s soft off policy? Who is responsible for updates? For other Soft Off Incidents see other states such as Ohio, Nevada